TC62D Installation Instructions

Similar documents
INSTALLATION/OPERATING INSTRUCTIONS MCP

INSTALLATION/OPERATING INSTRUCTIONS VSP. A Variable Speed Pump Control

DCC-2500 Digital Climate Control for Vintage Air GEN-IV systems

INSTALLATION/OPERATING INSTRUCTIONS TSC

Table of Contents Introduction 3 Chapter 2: Operation 4 Chapter 3: Components 5 Chapter 4: Specifications 8

DCC-3000 Climate Control for Vintage Air GEN-IV systems

Series 44 Installation Instructions

All of the control valves that we install the Mk. 16IQ positioner on are factory calibrated for proper operation prior to shipment.

BAPI-Stat Quantum Temperature Sensor with Display and Slider Setpoint

SetPoint 150 Controller Installation Manual

LK Control v.3 & LK Control v.3 - RA

BAPI-Stat Quantum Temperature Sensor with Display, Button Setpoint, Fan or System Mode Control

Operation and Installation Manual

ODYR-25-1 & SLX-25-1 rev. A VACUUM/BOOST PRESSURE, TEMP, and EGT GAUGE

SE8300 Series Installation Guide 24 Vac Low Voltage

Model No. DFC-X Support DIRECT FIRED DIGITAL TEMPERATURE CONTROL INSTALLATION, OPERATION, AND MAINTENANCE MANUAL

BAPI-Stat 3 Room Sensor

System 350 S350P Proportional Plus Integral Temperature Stage Module

SB 2000 PUSH TO SEARCH NEXT STAG E. Aerotech, Inc. FORM: QM 1320

SOLAR AQUA. Operation and Installation Manual LDLINE AQ-SOL-LV AQ-SOL-LV-TC AQ-SOL-LV-SP. Electronic Solar Control Center. for models CONTROLS INC.

GENERAL INFORMATION MECHANICAL INSTALLATION PRESSURE INDEPENDENT VALVES 2-1/2"-10" MVP INSTALLATION & OPERATION INSTRUCTIONS UNION CONNECTIONS

Combined Ventilation Controller RVWS-T-224HA

Inlet Controller TC5-ITA USER'S MANUAL. M rev. 02 K rev. 00

SMT-150 Installer Manual

Installation Manual. Mixing Box Control Systems Installation, Operation, and Maintenance Manual. 605 Shiloh Road Plano, Texas

Series 20 Installation Instructions

A419ABG-3C Electronic Temperature Control

RR Concepts. The StationMaster can control DC trains or DCC equipped trains set to linear mode.

ICM325HN. Head Pressure Control with Optional Heat Pump Override. Installation, Operation & Application Guide

A419 Series Electronic Temperature Controls with NEMA 1 or NEMA 4X Watertight Enclosures

! WARNING To avoid risk of electrical shock, personal injury or death; disconnect power to oven before servicing, unless testing requires power.

Factory Packaged Controls. OE (AAON Part No. V12090) MODGAS-X Controller Field Technical Guide

ESV. Electronic Steam Valve Control Modulates One or Two Actuators. Installation and Operation Manual ESV. Control Module

BAPI-Com, Two Wire Multifunction Sensor BA/BS4SCOM Temperature/Humidity Sensor Installation and Operating Instructions

Troubleshooting Bosch Proportional Valves

32XR. 3 Phase Duplex Pump Control Panel (Level Transmitter Based) Quick Start Guide

BAPI-Com, Two Wire Multifunction Sensor with Setpoint Slider (BA/BS4SCOM) Temperature/Humidity Sensor

AQUA SOLAR. Operation and Installation Manual AQ-SOL-LV AQ-SOL-LV-TC AQ-SOL-LV-SP. Electronic Solar Control Center. for models CON TROLS

T100A,F,M Controllers

R81EAA-2 Economizer Circuit Board

DFC-1 STANDARD TEMPERATURE CONTROL. DFC-2 TEMPERATURE CONTROL w/ INTEGRAL 40 F-90 F SELECTOR DFTD TEMPERATURE SELECTION DIAL DFTS TEMPERATURE SENSOR

ICM 326HN/327HN Line Voltage Head Pressure Control Installation, Operation & Application Guide

OnCommand Troubleshooting Guide Hayward Industries

BAPI-Stat 4 Room Humidity Sensor (BA/ B4 -H200 Series)

ESC2301. Universal Electronic Governor Controller Operation Manual

GL-235 Solar Pool Controller

A419 Series Electronic Temperature Controls with Display and NEMA 1 or NEMA 4X Watertight Enclosures

INSTALLER MANUAL USER MANUAL. Contents

Mash Tun / RIMS Tube Controller

GENERAL INFORMATION. H-1649, H-1650, H-1651 H-1653, H-1654 Easy-Count. uline.com. that may hurt accuracy:

SE8300 Series Installation Guide 24 Vac Low Voltage

Series 14R. Installation Instructions and Field Service Checklist

MAGPOWR Spyder-Plus-S1 Tension Control

Installation and User Manual. with RAIN SENSOR.

LTX RF LEVEL SENSOR. Instruction Manual

Installation Instructions

Tracer VMA with AutoReg

Revision THERMO TECHNOLOGIES. USDT 2001 Differential Controller. Installation and User s Guide

Power Flame Incorporated

SRC. An Outdoor Reset Control for Sub-Atmosphere Steam Systems OUTDOOR TEMPERATURE

Control. Part B, Section 2. This section covers the following unit configurations. 3400V 3500V. Voltage 4. Pump Piston (E, F, G)

Installation Instructions

CEMLINE CORPORATION P. O. BOX 55 CHESWICK, PENNSYLVANIA Phone: (724) FAX (724)

SSV2BR INSTRUCTIONS INSTALLATION INSTRUCTIONS

MDX-300 Series. For 12-volt automotive starting batteries and starting/charging systems INSTRUCTION MANUAL

ECCII to ECCIII Upgrade Kit

Installation. Aerada 1200 Series CS Faucet S Battery-Operated Capacitive Sensing Gooseneck Faucet IMPORTANT

Installation, Operation, and Maintenance Manual CEMLINE CORPORATION

RE Generation II Troubleshooting Guide Section I Preliminary Information and Evaluation

AD592/592-10K Non-Room Sensors in BAPI-Box, BAPI-Box 2 or BAPI-Box 4 BA/592-x-(BB, BB2, BB4) Temperature Sensor Instructions & Operation

Battery Management Innovation. For 12-volt automotive starting batteries and starting/charging systems INSTRUCTION MANUAL

Introduction. System Components

EG3000. Generator Electronic Governor Controller Operation Manual

Damper Actuator Installation

TECHNICAL NOTE #4 Revised May 24, BOGART ENGINEERING Two Bar Road, Boulder Creek, CA (831)

Features: Enhanced throttle response, excellent acceleration, strong brakes and throttle linearity. Using LED program card to make adjustments.

Temperature Controller OVATION 214 User's Guide

How to Retrieve a DTC (Without HDS)

User Manual Solar Charge Controller 3KW

MATRIX LLC LEVEL CONTROL PANEL

Installation, Operation, and Maintenance Manual CEMLINE CORPORATION

MICROPROCESSOR CONTROL WATER SUPPLY SYSTEM (MPR-01AW)

Maximiser Progressive Controller

BLOWER VACUUM SWITCH FAILED OPEN

MANUAL TROUBLESHOOTING. ECM Motor. ECM / ECM-DX Series. v100 Issue Date: 08/15/ Price Industries Limited. All rights reserved.

RVD110 RVD G2381en. Installation. Commissioning

INSTALLATION INSTRUCTION

RVD120 RVD G2510. Installation. Place of installation. Electrical installation. Permissible cable lengths

INSTALLATION AND OPERATION INSTRUCTIONS. Variable Speed Pump Control

Series 70 24V On/Off Electric Actuator Operation and Maintenance Manual

INSTALLATION AND OPERATION INSTRUCTION

Electronic Dynamo Regulator INSTRUCTION MANUAL. COPYRIGHT 2015 CLOVER SYSTEMS All Rights Reserved

Advanced Troubleshooting Guide Snorkel V Battery Charger Rev 0 3JAN07

SERIES 14 INSTALLATION INSTRUCTIONS and field service check list

PAGE Both power cords must be connected & powered to operate the E-TES SD 120 volt unit.

Inlet Controller SB3500 USER'S MANUAL

Solar Differential Temperature Controller Model DTC-D

2004 TSX - How to Troubleshoot the Climate Control System

Temperature Controller. TC5+2V4SA Plus USER'S MANUAL

Signet Temperature Transmitter

Transcription:

TC62D Installation Instructions January 2007 This TC62D has a return water low temperature limit option. Using the low limit precludes using a room sensor because both sensors plug into the same port. The return low limit sensor is included with the TC62D. The room temperature sensor is optional and is not included. The TC62D may be used as a single input (constant temperature) controller to control the temperature in swimming pools storage tanks and similar applications. This requires that the outdoor sensor be replaced by a calibrated plug. The plug is optional and is not included with the TC62D. Do not use a room temperature sensor in this mode. If this TC62D (VSE-2) is a replacement for or an upgrade to an older TC62 (VSE-1) or an older TC62D, the original supply and outdoor temperature sensors may be reused if they are still good. When the sensors are plugged in the controller displays an error message if they are defective. Also, the temperatures can be checked on the display. The ESBE 3-way & 4-way valves may be installed with either clockwise or counterclockwise rotation causing an increase in heat. The controller can be programmed to turn in either direction on an increased demand for heat. Do not remove the cover from the controller. Determine valve rotation You need to know which way the valve turns for more heat to program the TC62D rotation (line E). Valve rotation for 3-way valves Open the valve halfway. The pointer on the handwheel of 3-way valves points to the closed port as does the flat on the stem when you remove the handwheel. Halfway open is when the pointer on the handwheel points to the screw hole between the inlet from the boiler and the inlet from the system return port. If a 45º turn clockwise puts the pointer on the return inlet then the valve turns clockwise for more heat. Valve pointer position Valve pointer position Counterclockwise for more heat Clockwise for more heat Valve pointer position Valve pointer position Counterclockwise for more heat 1 Clockwise for more heat

Valve rotation for 4-way valves Set the pointer on the handwheel facing the supply line to the heating system (half open). If turning the handwheel clockwise moves it toward the return from the system the valve turns clockwise for more heat. Main pump Main pump Supply Supply Secondary pump (if used) Secondary pump (if used) return return Clockwise for more heat Counterclockwise for more heat Actuator Installation Set the valve half way open and remove the handwheel while keeping the valve half way open. Push the stem extender (1) onto the valve all the way. Screw the stop screw (2) into the lower right corner of the valve face. Make sure the actuator is in the middle. If it is not, push the hand knob in and turn it until the actuator is in the mid position. Place the actuator over the stem extender and push it into place with the locator pin over the stop screw. Fasten the controller to the valve with the screw (3) in the center of the handwheel. Select the red/blue scale (4) so that in the full heat position the widest part of the red band is beneath the pointer. Then, snap the cover (5) onto the handwheel. 2

Wiring Power Wiring The controller should be powered at all times. It must not be powered in parallel with the burner and/or circulator. Connect the open end of the power cable to a 24 volt transformer. Plug the other end into the jack labeled 24 VAC. The temperature sensors do not need to be shielded. If the code or specifications require them to be installed in conduit, do not put other wiring in the same conduit as the sensor, not even the 24 volt AC power wiring to the TC62D. Three sensors are included with the TC62D. Each is attached to a cable which plugs directly into the TC62D. The sensors are electrically identical. The one with the longest cable, (about 50 feet) is the outdoor sensor and the one with the shortest cable is for the supply water. Outdoor Sensor Find a location for the outdoor sensor on a north wall, if possible. Avoid exposure to direct sunlight or sources of heat such as dryer vents. Drill a 3/8 (10 mm) hole through the wall, push the sensor through from the inside, fasten it to the wall and then run the cable back to the controller. Coil up any excess cable and plug it into the jack labeled OUTDOOR or with this symbol: If you are using the TC 62D as a single input controller, insert the calibrated plug into the jack for the Outdoor Sensor and discard the sensor. Supply Water Sensor Install the supply water temperature sensor at least 18 (50 cm) from the valve preferably on the top of the pipe in a horizontal run. Make sure the pipe is clean and strap the sensor securely and tightly to the pipe. Insulate over the sensor for at least 6 inches (15 cm) in both directions from the sensor. Coil up any excess cable and plug it into the jack labeled PIPE or with this symbol: Water Sensor (Optional) Set P=2 if this sensor is used The return water sensor does not work in all applications. Please see pages 6 & 7 for the working requirements. If you use the return water sensor install it about 8 inches from the boiler return water inlet and insulate at least 6 inches from it in both directions. Do not cut the cable. Coil up any excess cable and plug the jack into the controller. The port is marked com. If you want to install a low limit in an existing TC62D, verify that it will work. Pull the power plug and plug it back in. The screen should display P03 and then 1.21 or higher. If the display is 1.13 the controller will not accept a return water low limit. Room Sensor (Optional) Set P=1 if this sensor is used A room sensor is not included with the TC62D. When you use one plug it in place of the return water low limit. If you choose to add a room sensor later, check the type of input jack for the sensor. Programming For most systems, the default settings work fine. Let the system stabilize for a few days before making changes. There are four programming buttons. The pair on the left (arrows) are used to scroll through the menu and the pair on the right (- & +) are used to set the values. The menu has 23 program lines; the first 5, A through E, can be reached simply by pressing the Menu Scroll Buttons; the remaining 18 lines are accessed by pressing both Menu buttons for about 5 seconds and then scrolling with the buttons. You can scroll forward and backwards through the program lines and can change any value at any time except the temperature scale. Program settings hold indefinitely; power failures do not cause memory loss. You can completely program the TC62D before you install it. You should have sensors plugged in while you are programming; without the supply and outdoor sensors the screen continuously flashes error messages. You can t program some room or return sensor functions unless the sensor is plugged in. The display shows the program line and the value for that line. If the line and its value are more than 3 characters the display alternates between displaying the line and displaying its value. When you first turn on the TC62D the display flashes some numbers for a few seconds and then stops at the default display value, which is usually line A. The display reads A20 if the scale is in Celsius and A68 if the scale is in Fahrenheit. The TC62D can be programmed in either Celsius or Fahrenheit, but the scale doesn t show in the display. If the number in the display isn t 68 for Fahrenheit or 20 for Celsius, it has been changed. The range is 5º - 30º C or 40º - 90º F So if the displayed setting is 40 or higher the controller is set in Fahrenheit. 3

Temperature Scales F or C (F is default) If you want to change, or be certain of the temperature scale, do the following: Press both menu buttons simultaneously and hold them until the display changes. Scroll to either 6 C to change to Celsius or 7 F to change to Fahrenheit and push the Plus button. Note: Changing the scale also resets the controller to the default values and any previous settings you changed will be lost. Press the Menu buttons simultaneously again for about 5 seconds to return to line A or wait about 30 seconds until the TC62D automatically defaults to line A. Function Line Default Range Room Temperature A 20º C or 68º F 5-30º C 40-90º F If you use a room sensor set this line at the room temperature you want. Adjusting the dial on the room sensor also changes the setpoint. Changes in the room temperature or the room temperature setting displace the reset curve. The amount of displacement is determined by the Room Sensor Authority setting (line t) If you do not use a room sensor, then line A causes a vertical displacement of the reset curve. A 1º degree change in Line A changes the reset curve about 3º. Reset Curve b 40º C or 100º F 22-90C 70-200º F This is the supply water temperature at 32º F (0º C) outside and line A set at 68º F. See the chart (last page) for the effect that changing this setting has at other outdoor temperatures. The reset curves have been selected to be especially applicable to most radiant heating systems. There are 6 lines of programming, 8, 9, h, J, L, & n, that allow you to modify the reset curve for particular conditions if the b setting needs adjustment. (See Curve Adjustment, next page) When you change line b, the controller does not immediately change internally; it slowly moves the setpoint to where you want it, taking about 5 minutes to change 10º F. For single point control this line is the setpoint: set the desired temperature here. Line Default Range Minimum Supply Temperature C 10º C or 50º F 10-90º C 50-200º F Maximum Supply Temperature d 70º C or 160º F 10-90º C 50-200º F Rotation E Clockwise to increase supply water temperature The indicator spins in the direction the actuator turns to increase heat. To turn counterclockwise to increase heat, press and hold the Minus button until the indicator spins counterclockwise. For clockwise motion use the Plus button. To adjust the remaining settings press both Menu buttons at the same time and hold them for about 5 seconds. Menu lines 0, 1, & 2 are indication only. They display temperatures in the scale you selected. Supply Temperature 0 Displays actual supply water temperature Calculated Supply Temperature 1 Displays what the supply temperature should be Outdoor Temperature 2 Displays outdoor temperature; always shows 32 F or 0 C in single point mode Function Line Default Range Outdoor Cutoff Temperature 3 17º C or 60º F 0-40º C 30-99º F Above this temperature the valve closes to heat; only recirculation occurs in the heating loop. This line will be inactive in single input control (the controller thinks it is always 32º F outside). Function Line Default Range Integral Time Amplification 4 5 1-10 Lower this value only if the controller hunts (cycles back & forth). Raising it makes the control respond faster, but may also cause hunting. Hunting is a continuous back & forth oscillation in the control. Hunting can also be caused by poor contact between the pipe and the pipe sensor or inadequate insulation around the sensor. Default Menu Row 5 A A This is the permanent display whenever the controller isn t being programmed. When you finish making adjustments, the display reverts to this line in about 30 seconds. Line A shows the room temperature setpoint. Another line may inserted in place of A such as line 2, the outside temperature, or line 0, the supply water temperature. 4

Curve Adjustment 8, 9, h, J, L, & n These lines read 0 as default You can modify the shape of the reset curve you selected in line b. At each of these outdoor temperature points you may modify the reset curve by +/- 10º C or 20º F. These lines are not used often in outdoor reset and should not be used at all in constant temperature control. Line Out. Temp C Out. Temp F Line Out. Temp C Out Temp F 8-30 -22 J 0 32 9-20 -4 L 6 43 h -10 14 n 12 54 Function Line Default Range or Room Sensor Function P 2 or 0 0, 1, or 2 0 no sensor 1 Third sensor is in the controlled space. 2 Third sensor is in the boiler return. or Room Sensor Display r This is the temperature at the third sensor, room temperature if the sensor is in the controlled space, or the boiler return if the sensor is located there. Water Low Limit t 90º F or 30º C 90º - 140º F 30º - 60ºC This is active only if the third sensor function is set for boiler return low limit. This function can not be used in every installation. Please see the next 2 pages if you want to use it. Differential U 5º 1º - 10º ( F or C) The boiler return water temperature must increase by this amount above the value set in t before the reset control function takes control. Room Sensor Authority t 2º 0º - 3º (F or C) This is the amount 1 degree change in room temperature will change the supply water temperature in the opposite direction. This function is only active when you use a room sensor and set the third sensor function at 1. Troubleshooting If the TC62D doesn t work properly, the problem is usually easy to fix. Sometimes, when changes are made rapidly, the TC62D does not seem to respond correctly. Disconnect the power for a few seconds and the reconnect it. Your last set of instructions remain in the controller and it should respond correctly. Check to make sure the voltage is correct; it must be 24 volts AC ±10%. If the control transformer powers other devices the voltage may be drawn down below the acceptable limit. Make sure the sensors are plugged into the correct jack and that Line P is set to the correct value. Double check the valve and actuator assembly. There are no stops in the valve; if the controller is installed in the wrong position the valve may go past the closed position and begin to open. Check the rotation. If the TC62 is programmed with the wrong rotation the valve will be driven to one end position or the other and will stay there. The screen can display 7 error codes and, in most cases, the controller takes a specific action when the error occurs: ERR 1 Outside temperature sensor is shorted. The controller assumes it is 32º F outside. ERR 2 Outside sensor is open or not connected The controller assumes it is 32º F outside. ERR 3 Supply water temperature sensor is shorted. The controller drives the valve half open. ERR 4 Supply water sensor is open or not connected. The controller drives the valve half open. ERR 5 The room or return temperature sensor is shorted. The controller functions without the sensor. ERR 6 The room or return sensor is out of range. The controller functions without the sensor. ERR 7 There is an internal problem. No controller action; replace it. 5

Using the water Low Limit Function 4-way Valves V4R Mixing Valve with TC62D Secondary Pump Secondary Loop Supply Sensor Below the setting of the boiler water return low limit there will be 100% recirculation in the primary loop (and the secondary loop). When the temperature rises above the setting + the differential setting the TC62D then works as a reset controller. If there is no pump in the primary loop or it isn t running, then the only circulation in the primary loop will be by gravity and the temperature in the boiler return will take a long time, if ever, to rise high enough for the reset function to take over. Primary Loop Primary Pump Low Limit Sensor 3-way Valves Recirculation Pump Low Limit Sensor V3R valve with TC62D Secondary Pump Supply Sensor If if there is no recirculation pump or it isn t running, the temperature in the boiler return may not rise high enough for the TC62D to work as a reset controller. Also, if there is not enough flow through the recirculation line, the boiler return temperature may not be high enough for the reset function to take over. Programming Set Line P at 2 Set Line t at desired low limit (90º F - 140ºF) Set line U at desired differential (1º - 10º) Below t the TC62D controls from the low limit sensor. When the temperature at the low limit sensor is above t + U the TC62D is a reset controller that works from the temperature at the supply sensor and the outdoor temperature. 6

200 Supply Water Temperature ºF 180 160 140 120 100 80 60 160 140 120 100 90 80 40 70 60 50 40 30 20 10 0-10 -20-30 -40 Outdoor Temperature ºF The reset curve shown at 100º F is the default value. If you set b at 110º, the controller follows a reset curve between the samples at 100º and 120º. Supply Water Temperature ºF 100 80 60 40 Low Limit (Line C) Cut-off Temperature (Line 3) High Limit (Line D) Vertical Displacement (Line A) 60 50 40 30 20 10 0-40 Outdoor Temperature ºF 140 A sample reset curve with high limit, low limit and cut-off settings applied 7

Programming Summary Program lines A, b, C D, & E are set by scrolling to them with the Arrow keys and adjusting them with the + & - keys. The remaining programming lines are set by first holding both Arrow keys for 5-10 seconds and then scrolling through them as with lines A - E. Valve Rotation E Valve turns clockwise for more heat + Valve turns counterclockwise for more heat - Room Temperature Setting Activate Room Temperature Control P Set line P to 1 Room Temperature Setpoint A Room Sensor Authority t Reset Curve Curve Selection b Minimum Supply Water Temperature C Maximum Supply WaterTermperature D Outdoor Cut-off Temperature 3 Vertical Curve Displacement A Redraw Reset Curve 8, 9, h, J, L, & n Displays Actual Supply Water Temperature 0 Correct Supply Water Temperature 1 Outdoor Temperature 2 or Room Temperature (if used) r Set the Default Menu Display 5 Water Low Limit Activate Low Limit P Set line P to 2 Low Limit Setpoint t Differential U Reset the TC62D the control to factory settings Fahrenheit 7 + Celsius 6 + Temperature Vs. Resistance For TC62 Sensors Resistance is in 1000ʼs of ohms. All the sensors have the same curve. Temperature Resistance C F KΩ -30-22 314.8-25 -13 237.8-20 -4 181.2-15 5 139.2-10 14 107.8-5 23 84.2 0 32 66.2 5 41 52.4 10 50 41.8 Temperature Resistance C F KΩ 15 59 33.0 20 68 27.1 25 77 22.0 30 86 18.0 35 95 14.8 40 104 12.2 45 113 10.1 50 122 8.6 Temperature Resistance C F KΩ 55 131 7.1 60 140 6.0 65 149 5.0 70 158 4.3 75 167 3.7 80 176 3.1 85 185 2.7 90 194 2.3 8