Level 3 Award in the Requirements for Electrical Installations BS 7671:2018 ( )

Similar documents
Major changes within the New 18 th Edition Wiring Regulations announced by The IET

On-Site Guide (BS 7671:2008 Wiring Regulations, incorporating Amendment No 1:2011)

The impact of the 18 th Edition (BS 7671:2018) Sections 722, 753 and [new] 730

The Impact of the 18 th edition (BS 7671:2018)

On_Disc. 2 o/c1 BS 7671 applies to a lift installations b highway equipment c equipment on board ships d electrical equipment of machines.

Electric Vehicle Charging Safety Guidelines Part 2: Selection and Installation Edition DRAFT

Electric Vehicle Charging Safety Guidelines Part 2: Selection and Installation

18TH EDITION BS7671 HOW THIS AFFECTS YOU. BITESIZE II. wylexreasons.co.uk WHY CHOOSE ANYTHING LESS?

Renewable sources of electricity a brief overview

3 o/c 2 An area or temporary structure used for display, marketing or sales is defined as a a booth b a stand c an exhibition d a show.

WIRING MATTERS SEPTEMBER 2018

Guide to the IET Wiring Regulations

IET Wiring Regulations (BS 7671:2008+A3:2015) - SECTION 717 MOBILE OR TRANSPORTABLE UNITS

ELECTRICIANS REGULATIONS EXAMINATION 25 June 2011

Reviewed: DD Month University Code of Practice for Electrical Safety. PART B - Design and Construction of Electrical Equipment within the University

NZQA registered unit standard version 1 Page 1 of 5

SELECT MEMBERSHIP NUMBER Full Installation 75% new and 25% alteration to exsisting

E.V.READY Specification for Installer Training Content

ELECTRICAL INSPECTOR EXAMINATION 14 November 2015 QUESTION AND ANSWER BOOKLET Time Allowed: Three hours

ELECTRICIAN S REGULATIONS EXAMINATION 26 June 2010

Key elements of the AS3000 Wiring standards and some of the recent changes.

City & Guilds 2381 Test 2382 Level 3. Which one of these electrical installations does BS 7671:2008 not apply to:

ELECTRICIANS REGULATIONS EXAMINATION 23 November 2013 QUESTION AND ANSWER BOOKLET

EARTHING YOUR QUESTIONS ANSWERED

CLP POWER HONG KONG LIMITED. SUPPLY RULES March 2001

NZQA registered unit standard version 1 Page 1 of 5. Apply and remove portable earths in an electricity supply system

Books. Code of Practice for In-Service Inspection and Testing of Electrical Equipment (3rd edition) By IET Publication

The Management of Electrical Safety in Quarries, Associated Plant and Equipment

2 The IEE Regulations, BS 7671 and this Guide Note on Supply Voltage Level For many years the supply voltage for single-phase supplies in the UK has b

PUBLIC NOTICE. 1. Central Electricity Authority (Technical Standards for Connectivity of Distributed Generation Resources) Regulations, 2013.

National Certificate in Electricity Supply (Distribution Faultman) (Level 4) with strands in Line Mechanic, and Electrician

STANDARD TECHNIQUE : SD5P/2

Guidance for Low Voltage Electrical Installations

NZQA registered unit standard version 3 Page 1 of 5. Demonstrate and apply knowledge of electrical machines

Initial and Periodic Inspection and Testing of Electrical Installations ( ) Sample Test

Elbasen. English version. Guide to electrical installations. Edition 2

NZQA registered unit standard version 1 Page 1 of 6

ELECTRICAL INSTALLER EXAMINATION 18 November 2017 QUESTION AND ANSWER BOOKLET

Earthing Principles. Symmetra PX 250/500 kw

ES5. Candidate Code No. For Board Use Only. Result Date Int. Result Date Int

ELECTRICIAN S THEORY EXAMINATION 19 June 2010 QUESTION AND ANSWER BOOKLET

ELECTRICIANS REGULATIONS EXAMINATION 29 June 2013 QUESTION AND ANSWER BOOKLET

Wiring Matters November 2018

SNZ TR 6120:2014. New Zealand Technical Report. Low voltage supply earthing systems SNZ TR 6120:2014

Risk Management of Rail Vehicle Axle Bearings

SYSTEM EARTHING & PROTECTIVE EARTHING

ELECTRICIAN S THEORY EXAMINATION 20 June 2015 QUESTION AND ANSWER BOOKLET

A guide for the connection of a low voltage installation to The Guernsey Electricity Network

SLOVAK UNIVERSITY OF TECHNOLOGY Faculty of Material Science and Technology in Trnava ELECTRICAL ENGINEERING AND ELECTRONICS.

Australian/New Zealand Standard

Electric Vehicle Charging Safety Guidelines Part 1: Safety Fundamentals Edition DRAFT

Higher National Unit Specification. General information for centres. Electrical Motor Drive Systems. Unit code: DN4K 35

Effective discrimination of protective devices

STANDARDS SOUTH AFRICA. Amendment No. 5 : May SANS :2006 (Ed 1.5) THE WIRING OF PREMISES PART 1: LOW-VOLTAGE INSTALLATIONS

This document is a preview generated by EVS

NZQA registered unit standard version 4 Page 1 of 5

Guidelines for connection of generators:

Technical information No. 01. IT systems. The basis for reliable power supply

BS : C&G 2382 Outcomes 4

ELECTRICAL INSPECTOR EXAMINATION 18 November 2017 QUESTION AND ANSWER BOOKLET Time Allowed: Three hours

National Certificate in Electricity Supply (Line Mechanic Distribution) (Level 4)

ELECTRICIAN S THEORY EXAMINATION 21 June 2014 QUESTION AND ANSWER BOOKLET

Demonstrate knowledge of electrical theory for Electrical Service Technician B

TECHNICAL SPECIFICATION

Certification Memorandum. Approved Model List Changes

Research Brief. Impact of higher 25kV fault currents. T873 - October Background. Aims

Equipotential Bonding of Rail Vehicles to Running Rail Potential

SOUTH AFRICAN NATIONAL STANDARD

Chapter P Residential and other special locations

Fundamentals and Earthing

ELECTRICIANS REGULATIONS EXAMINATION 30 June 2012 QUESTION AND ANSWER BOOKLET

EDS CUSTOMER LV INSTALLATION EARTHING DESIGN

GT/TDINT100 Issue: 1 Date: SEP 1993 Page 1 of 11

EDS CUSTOMER LV INSTALLATION EARTHING DESIGN

FINAL-ER 42 Electrician Regulations Answer Schedule

UTILITY ASPECTS OF GRID CONNECTED PHOTOVOLTAIC POWER SYSTEMS

Higher National Unit Specification. General information for centres. Electrical Motors and Motor Starting. Unit code: DV9M 34

Australian/New Zealand Standard

SOUTH AFRICAN NATIONAL STANDARD. Plug and socket-outlet systems for household and similar purposes for use in South Africa

LEP ASSESSMENT REVIEW

Control, Safe Use and Operation of Excavators, Loaders and Earth Moving Equipment

This qualification has been reviewed. The last date to meet the requirements is 31 December 2020.

Rail Safety and Standards Board

Low Voltage Power Supplies in Electrified Areas

Contents. 1 Introduction. 2. Advisory and Information Systems. 3. Supply. 3.1 Quality of Electric Supply. 3.2 Interference with other Customers

IN-SERVICE SAFETY INSPECTION and TESTING OF ELECTRICAL EQUIPMENT

Candidate Handbook answers

NZQA unit standard version 8 Page 1 of 5. Apply and remove earths from conductors on electricity supply networks

ELECTRICIAN S THEORY EXAMINATION 11 September 2010 QUESTION AND ANSWER BOOKLET

Investigation into UK socket-outlets incorporating USB charging points

NPS/001/017 Technical Specification for Low Voltage and High Voltage Current Limiting Fuse Links

Unit title: Tractor Operations and Attachments (SCQF level 5)

NPS/003/010 - Technical Specification for 400V Assemblies (LVAC Boards) utilised in Major Substations

National Certificate in Motor Industry (Automotive Machining)

90.2 Scope. The installation of electrical conductors, equipment and raceways for:

ECE/RCTE/CONF/4/Add.1/Rev.2

Electrical test equipment for use on low voltage electrical systems

Mode 2 Charging Testing and Certification for International Market Access

Title High Voltage and 1500 System Earthing References and Definitions. Reference Number PDS 02 (RIC Standard: EP SP)

This standard covers the requirements of lighting chains. This standard covers only the safety requirements.

Transcription:

Level 3 Award in the Requirements for Electrical Installations BS 7671:2018 (2382-18) March 2018 Version 1.0 FAQs

1 18 th Edition IET Wiring Regulations 2018 FAQs When will the 18 th Edition of BS 7671 be published? The publication date is on target for 1 st July 2018. The cover colour will be blue to replace the current yellow book. What about my yellow copy of BS 7671:2008(2015); when does that expire? Both the new 18 th Edition (blue cover) and the old 17 th Edition (yellow cover) will be current documents until January 2019. From January 2019 only the 18 th Edition (blue cover) will be permitted when designing, erecting, and inspecting and testing electrical installations. What will happen to 2382? From 1st July 2018, we will launch a new complex - the 2382-18 for centres to register candidates against. This new qualification will be assessed by a 60 item multiple choice examination that is delivered onscreen via our e-volve system. The examination will have a 2-hour duration. This assessment will align fully to the new 18 th Edition (Blue). The current qualification 2382-15 will be open for registration until 31 st December 2018. Certification for 2383-15 will close from 31 st March 2019. Will there be an assessment available to cover only the differences between the 17 th and 18 th edition? No, an agreement was made between all Awarding Organisations and the JIB that all examinations based on BS 7671 should assess that candidates are able to demonstrate understanding of all parts, not just changes between editions. In terms of course delivery, centres may wish to offer update courses with a shorter duration that only teaches the differences between the 17 th and 18 th Editions. However, centres should take the necessary steps to ensure that candidates knowledge is up to date and sound before accepting them onto a shortened course. Candidates who take a shortened course will still need to sit the same assessment as candidates who take the full course. What s the impact on other electrical short courses? 2391 There will be no noticeable changes to 2391-50, 51 and 52. We will ensure that all questions are BS 7671 neutral, meaning that any exam taken between July 2018 and January 2019 will be in line with both the 17 th Edition and the 18 th Edition. This will continue until 1 st January 2019, when the 17 th Edition will expire and the 18 th Edition will be the only permitted material. This also applies to any update to Guidance Note 3 and the IET On-site Guide. We are expecting that these updated publications will be available during July 2018. 2377 2377 will not undergo any changes at present and will remain aligned to the current IET Code of Practice for the In-service Inspection and Testing of Electrical Equipment. Other qualifications that are affected by the changes and will be version neutral, between July 2018 and January 2019 include: Open book - 2393, 2396, 2397, 2919 Closed book - 2392

What s the impact on the examinations within the apprenticeships (2357 and 5357) and full time qualifications (2365 and 8202)? The following assessments won t be impacted by these changes: 2365 601, 602, 301, 309 2357 102 5357 001, 003, 005 The following assessments will be amended to be version neutral, meaning candidates will be able to answer questions with knowledge of either the 17 th edition or the 18 th edition between July 2018 and August 2019. From September 2019, these assessments will assess content based on the 18 th edition only. 2365 203, 623, 624, 625 2357 305, 107 5357 004, 012, 014 New assessment numbers will replace the following assessments numbers: 5357 016 will be replaced by 018, from September 2019, 016 will be closed and all examinations will need to be booked under 018. 2357 006 will be replaced by 007, from September 2019, 006 will be closed and all examinations will need to be booked under 007. For the 8202, all 2018 assessments, at both level 2 and 3, will assess against the 17 th Edition standard. All assessments, at all levels, for the academic year 2018/19 onwards will assess against the 18 th Edition standard. What s the impact on all centre marked assessments? From 1 st July 2018, all centre marked assessments will contain dual marking schemes. Marking schemes will provide marking guidance as to what is a suitable response in relation to the 17 th Edition or 18 th Edition. This will give assessors the flexibility when marking to accept answers relevant to either the 17 th or 18 th edition. Centres will mark according to the version of BS 7671 being used by the candidate. These dual mark schemes will remain effective until August 2019. What other publications are changing? The IET are in the process of updating all Guidance Notes 1-8, The On-site Guide and The Electricians Guide to the Building Regulations. It is expected that all of these publications will be published by the end of July 2018. In addition, the City & Guilds textbooks are expected to be updated and available from September 2018.

What are the main changes to BS 7671? Below is an official list from IET of the main changes to BS 7671. It must be noted that there are further changes throughout the publication in addition to those below. Part 1 Scope, object and fundamental principles Regulation 133.1.3 (Selection of equipment) has been modified and now requires a statement on the Electrical Installation Certificate. Part 2 Definitions Definitions have been expanded and modified. Chapter 41 Protection against electric shock Section 411 contains a number of significant changes. Some of the main ones are mentioned below. Metallic pipes entering the building having an insulating section at their point of entry need not be connected to the protective equipotential bonding (Regulation 411.3.1.2). The maximum disconnection times stated in Table 41.1 now apply for final circuits up to 63 A with one or more socket-outlets and 32 A for final circuits supplying only fixed connected current-using equipment (Regulation 411.3.2.2). Regulation 411.3.3 has been revised and now applies to socket-outlets with a rated current not exceeding 32A. There is an exception to omit RCD protection where, other than a dwelling, a documented risk assessment determines that RCD protection is not necessary. A new Regulation 411.3.4 requires that, within domestic (household) premises, additional protection by an RCD with a rated residual operating current not exceeding 30 ma shall be provided for AC final circuits supplying luminaires. Regulation 411.4.3 has been modified to include that no switching or isolating device shall be inserted in a PEN conductor. Regulations 411.4.4 and 411.4.5 have been redrafted. The regulations concerning IT systems (411.6) have been reorganized. Regulations 411.6.3.1 and 411.6.3.2 have been deleted and 411.6.4 redrafted and a new Regulation 411.6.5 inserted. A new Regulation group (419) has been inserted where automatic disconnection according to Regulation 411.3.2 is not feasible, such as electronic equipment with limited short-circuit current. Chapter 42 Protection against thermal effects A new Regulation 421.1.7 has been introduced recommending the installation of arc fault detection devices (AFDDs) to mitigate the risk of fire in AC final circuits of a fixed installation due to the effects of arc fault currents. Regulation 422.2.1 has been redrafted. References to conditions BD2, BD3 and BD4 have been deleted. A note has been added stating that cables need to satisfy the requirements of the CPR in respect of their reaction to fire and making reference to Appendix 2, item 17. Requirements have also been included for cables that are supplying safety circuits. Chapter 44 Protection against voltage disturbances and electromagnetic disturbances Section 443, which deals with protection against overvoltages of atmospheric origin or due to switching, has been redrafted. The AQ criteria (conditions of external influence for lightning) for determining if protection against transient overvoltages is needed are no longer included in BS 7671. Instead, protection against transient overvoltages has to be provided where the consequence caused by overvoltage (see Regulation 443.4):

(a) results in serious injury to, or loss of, human life, or (b) results in interruption of public services/or damage to and cultural heritage, or (c) results in interruption of commercial or industrial activity, or (d) affects a large number of co-located individuals. For all other cases, a risk assessment has to be performed in order to determine if protection against transient overvoltage is required. There is an exception not to provide protection for single dwelling units in certain situations. Chapter 46 Devices for isolation and switching A new Chapter 46 has been introduced. This deals with non-automatic local and remote isolation and switching measures for the prevention or removal of dangers associated with electrical installations or electrically powered equipment. Also, switching for the control of circuits or equipment. Where electrically powered equipment is within the scope of BS EN 60204, only the requirements of that standard apply. Chapter 52 Selection and erection of wiring systems Regulation 521.11.201, which gives requirements for the methods of support of wiring systems in escape routes, has been replaced by a new Regulation 521.10.202. This is a significant change. Regulation 521.10.202 requires cables to be adequately supported against their premature collapse in the event of a fire. This applies throughout the installation and not just in escape routes. Regulation 522.8.10 concerning buried cables has been modified to include an exception for SELV cables. Regulation 527.1.3 has also been modified, and a note added stating that cables also need to satisfy the requirements of the CPR in respect of their reaction to fire. Chapter 53 Protection, isolation, switching, control and monitoring This chapter has been completely revised and deals with general requirements for protection, isolation, switching, control and monitoring, and with the requirements for selection and erection of the devices provided to fulfil such functions. Section 534 Devices for protection against overvoltage This section focuses mainly on the requirements for the selection and erection of SPDs for protection against transient overvoltages where required by Section 443, the BS EN 62305 series, or as otherwise stated. Section 534 has been completely revised and the most significant technical change refers to the selection requirements for the voltage protection level. Chapter 54 Earthing arrangements and protective conductors Two new regulations (542.2.3 and 542.2.8) have been introduced concerning earth electrodes. Two further new regulations (543.3.3.101 and 543.3.3.102) have been introduced. These give requirements for the insertion of a switching device in a protective conductor, the latter regulation relating to situations where an installation is supplied from more than one source of energy. Chapter 55 Other equipment Regulation 550.1 introduces a new scope. New Regulation 559.10 refers to ground-recessed luminaires, the selection and erection of which shall take account of the guidance given in Table A.1 of BS EN 60598-2-13.

Part 6 Inspection and testing Part 6 has been completely restructured, including the regulation numbering to align with the CENELEC standard. Chapters 61, 62 and 63 have been deleted and the content of these chapters now forms two new Chapters 64 and 65. Section 704 Construction and demolition site installations This section contains a number of small changes, including requirements for external influences (Regulation 704.512.2), and a modification to Regulation 704.410.3.6 concerning the protective measure of electrical separation. Section 708 Electrical installations in caravan/camping parks and similar locations This section contains a number of changes including requirements for socket-outlets, RCD protection, and operational conditions and external influences. Section 710 Medical locations This section contains a number of small changes including: The removal of Table 710, Changes to Regulations 710.415.2.1 and 710.415.2.3 concerning equipotential bonding, A new Regulation 710.421.1.201 which states for all final circuits supplied by medical IT systems in medical locations of group 2, AFDD shall not be used. Section 715 Extra-low voltage lighting installations This section contains only minor changes including modifications to Regulation 715.524.201. Section 721 Electrical installations in caravans and motor caravans This section contains a number of changes including requirements for electrical separation, RCDs, proximity to non-electrical services and protective bonding conductors. Section 722 Electric vehicle charging installations This section contains significant changes to Regulation 722.411.4.1 concerning the use of a PME supply. The exception concerning reasonably practicable has been deleted. Changes have also been made to requirements for external influences, RCDs, socket-outlets and connectors. Section 730 Onshore units of electrical shore connections for inland navigation vessels This is an entirely new section and applies to onshore installations dedicated to the supply of inland navigation vessels for commercial and administrative purposes, berthed in ports and berths. Most, if not all, of the measures used to reduce the risks in marinas apply equally to electrical shore connections for inland navigation vessels. One of the major differences between supplies to vessels in a typical marina and electrical shore connections for inland navigation vessels is the size of the supply needed. Section 753 Floor and ceiling heating systems This section has been completely revised. The scope of Section 753 has been extended to apply to embedded electric heating systems for surface heating. The requirements also apply to electric heating systems for de-icing or frost prevention or similar applications, and cover both indoor and outdoor systems. Heating systems for industrial and commercial applications complying with IEC 60519, IEC 62395 and IEC 60079 are not covered.

Appendices The following main changes have been made within the appendices: Appendix 1 British Standards to which reference is made in the Regulations. Includes minor changes, and additions. Appendix 3 Time/current characteristics of overcurrent protective devices and RCDs The previous contents of Appendix 14 concerning earth fault loop impedance have been moved into Appendix 3. Appendix 6 Model forms for certification and reporting This appendix includes minor changes to the certificates, changes to the inspections (for new installation work only) for domestic and similar premises with up to 100 A supply, and examples of items requiring inspection for an electrical installation condition report. Appendix 7 (informative) Harmonized cable core colours This appendix includes only minor changes. Appendix 8 Current-carrying capacity and voltage drop This appendix includes changes regarding rating factors for current-carrying capacity. Appendix 14 Determination of prospective fault current The contents of Appendix 14 concerning earth fault loop impedance have been moved into Appendix 3. Appendix 14 now contains information on determination of prospective fault current. Appendix 17 Energy efficiency This is a new appendix that provides recommendations for the design and erection of electrical installations, including installations having local production and storage of energy for optimizing the overall efficient use of electricity. The recommendations within the scope of this appendix apply for new electrical installations and modification of existing electrical installations. Much of this appendix will not apply to domestic and similar installations. It is intended that this appendix is read in conjunction with BS IEC 60364-8-1, when published in 2018 Text in green is courtesy of IET news release 1 st March 2018.