ortable ph, Conductivity & DO2 Meters

Similar documents
ELPRO Lepenik & Co. d.o.o., Ob gozdu 7c, Rogoza, 2204 Miklavž na Dravskem polju, Slovenija tel:

PROHOOD AIR CAPTURE HOOD MODEL PH731

Water analysis, QC and more:

VELOCICALC MULTI-FUNCTION VENTILATION METER MODEL 9565

SERVICE MANUAL STARTER 2100 Bench ph Meter STARTER 3100 Bench ph Meter STARTER 3100C Bench ph Meter

ULTRAFLO 2000 ULTRASONIC LIQUID FLOW AND HEAT/ENERGY METERS FOR PERMANENT INSTALLATION HIGH TEMPERATURE SENSORS AS STANDARD

PC60 Premium Multi-Parameter Tester (ph/ec/tds/salinity/temp.) Instruction Manual. APERA INSTRUMENTS, LLC V6.4

EiUK. Multi-Purpose Flue Gas Analyser. Service is what matters to most of us! Only 2 days turnaround

SERVICE MANUAL. STARTER Portable Meter ST300 ST300C ST300D ST400D. Ohaus Corporation, 7 Campus Drive, Suite 310, Parsippany, NJ (973)

IAQ-CALC TM Indoor Air Quality Meter

Personal ph, ph/orp, Conductivity Meters

COM-100 EC / TDS / TEMPERATURE METER

Bante220 Portable ph Meter Instruction Manual

Dräger CMS. Dräger CMS: Highly accurate and easy to use. Dräger CMS Chip: Miniaturised Dräger-Tubes.

Instruction Manual Portamess 911 Cond

ECscan30 Pocket Conductivity/TDS Tester Instruction Manual

Environmental/Analytical LabCivil Engineering Lab Equipment

AKVdiesel. Automated kinematic Viscometer key features. Fully complies with ASTM D445. Two measuring positions. Remove cap and pour in sample

ISOCAL - 6 Range Europa Venus Calisto

Conductivity Measurement CLM 280

Salt 1 Pocket Salinity Tester Instruction Manual

AGUABEL. Index. Aguapure Aguapure Lara APS 3. P-Pump 4. Aspendose 5. Tank for chemical 6. Tank with mixer 6. Glass Sensor 7.

Large Display ph Pens , , Instruction Manual

GHMsilverline Handheld Instruments

Incubators. Incubators

CPM280. Technical Information. ph/orp measurement Battery-driven pocket meter for ph and ORP measurement

OD DISSOLVED OXYGEN METER

INSTRUCTION MANUAL. Handy Polaris

WalkLAB Digital Dissolved Oxygen meter HD9030

ECscan40 Pocket Conductivity/TDS/Salinity Tester Instruction Manual

CORRECTION FACTORS FOR OXYGEN SOLUBILITY AND SALINITY

the experience of many

PH60 Series Premium ph Testers

HI Portable Waterproof Skin ph Meter INSTRUCTION MANUAL

USER S GUIDE WARRANTY. This manual and all information contained herein is copyright HM Digital, Inc. ONE YEAR LIMITED WARRANTY

Care and use guide Guía de uso y cuidado Guide d utilisation et d entretien.

ScienceLine ph combination electrodes

OD DIGITAL DISSOLVED OXYGEN CONTROLLER POLAROGRAPHIC CELL

Drying ovens. ED Drying oven with natural convection. Performance features and equipment :

Dissolved Oxygen Measurement System with Air Blast Cleaner

ABB MEASUREMENT & ANALYTICS DATA SHEET Hydrazine monitor

HUMIDITY / TEMPERATURE TRANSMITTER

OD OD DIGITAL DISSOLVED OXYGEN CONTROLLERS

ecotrans Lf 01/02 Microprocessor Transmitter / Switching Device for Conductivity

EC1 Pocket Conductivity Tester Instruction Manual

TRACER. POCKETESTER ä ORP CODE 1742

Marin Control Digital

AP300 Series Combination ph/redox (ORP) Sensors. Measurement made easy. A reliable economic solution for a wide range of applications

8,1,8,1,2,7,2,7,6,3,6,3,4,5,4,5

JUMO tecline HD ph and JUMO tecline HD Rd

Signet 2850 Conductivity/Resistivity Sensor Electronics and Integral Systems with PVDF Sensor

Design of Phase Comparators

Pressure Transmitter

Aqua Metrix. Water Analytics AquaMetrix Price List. AquaMetrix products are manufactured by. Water Analytics

Dräger CMS Chip Measurement System

Energy Division. PCA Single Column Polymeric Surge Arrester

Data Sheet No 241 Jan 2002 Issue G. Electrode Holders & Brackets for Conductivity Type Systems

TABLE OF CONTENTS. Firmware Version

STARTER 2000 Bench ph Meter Instruction Manual

EC20 Pocket Conductivity Tester Instruction Manual

SOLENOID DRIVEN DOSING PUMPS MX series

MODEL IQ150 ph Meter Getting Started TWO-POINT CALIBRATION--QUICK REFERENCE GUIDE

Elcometer 506 Pull- Off Adhesion Gauge. elcometer.com 1

PCE Americas Inc. 711 Commerce Way Suite 8 Jupiter FL USA From outside US: +1 Tel: (561) Fax: (561)

Drying ovens. FD 53 - Drying oven with forced convection. Performance features and equipment :

AZ-8904 THERMO ANEMOMETER

the PROFI-Line II Portable compressors for toughest operations l/min 225 / 330 bar Alu-Frame

Digital ph transmitter

Thermo-anemo-manometer MP 210

Visit us at

Operation Manual MODEL EC331. Microcomputer Based Conductivity /Resistivity & Temperature Pocket Meter EC331

TENSION LOAD. Product Overview

Cellwatch Battery Monitoring Systems

ECscan20 Pocket Conductivity Tester Instruction Manual

Digital ph transmitter

Global Water Instrumentation, Inc.

ABB MEASUREMENT & ANALYTICS DATA SHEET. AC200 Series Industrial 2-electrode conductivity cells with rapid temperature response

Measuring Cells for free chlorine, chlorine dioxide, ozone

Elcometer 506 Pull- Off Adhesion Gauge. Product Brochure/Flyer. 506 PAT Adhesion Tester

USER MANUAL: JCI 147 Faraday Pail

PHscan30S Pocket ph Meter Instruction Manual

AT8060 BREATH ALCOHOL TESTER USING MANUAL. Ver: HW Catalogue

PH20 Value ph Tester Instruction Manual

NEW QUICK CABLE-TO-SENSOR RELEASE,

ORPscan20 Pocket ORP Tester Instruction Manual

MEASUREMENT AND INSTRUMENTATION FLS

Tracer ORP PockeTester TM Code 1742

Conductivity meter. PLC Solenoid valve. Type Type On/Off Diaphragm valve. Valve islands

OPERATION MANUAL. THE JENCO MODEL 3671 ph/orp CONTROLLER JENCO ELECTRONICS, LTD. MANUFACTURER OF PRECISION INSTRUMENTS

Beamex MB METROLOGY TEMPERATURE BLOCK. Portable temperature dry block delivering bath-level accuracy for industrial applications

JUMO ecotrans Lf 01/02

Visit us at

Laboratory Method Evaluation Report GBRA, August 2013

OEM Pressure Transmitters

Station Class Polymeric Surge Arresters

IT SIMPLY WORKS. EMISSION. // Emission control devices

DLRO 10 and DLRO 10X. Digital Microhmmeter. DLRO 10 and DLRO 10X Digital Microhmmeter. NEW interchangeable test lead terminations

General Specifications

A Higher Level of Performance. Data Sheet. Centurion. Guided Radar. CGR Series. For more information, please visit >

Metso Conductivity for sensor series 9400 and 9500

Transcription:

ortable ph, Conductivity & DO2 Meters Enterprise Range Large, back lit LCD Ergonomic design These ergonomically designed products feature a backlit liquid crystal display, a reading hold function and 500 hours 500 hours battery life battery life. Ideal for field or any portable situation. Order Code 350 201 Model 350 ph meter supplied with epoxy combination electrode, 4, 7 and 10 ph buffer sachets and instructions 350 271 Model 350 ph meter supplied as above in FREE carry case 370 201 Model 370 ph/mv/temp meter supplied with epoxy combination electrode, ATC probe, 3 sachets of 4, 7 and 10 ph buffer and instructions 370 271 Model 370 ph/mv/temp meter supplied as above in FREE carry case 430 201 Model 430 ph/conductivity meter supplied with combined ph/conductivity probe (430 231), 4, 7, 10 ph buffer sachets, batteries (fitted) and operating instructions 430 271 Model 430 ph/conductivity meter supplied as above in FREE carry case 470 201 Model 470 Conductivity/TDS meter supplied with epoxy cell K=1 and instructions 470 271 Model 470 Conductivity/TDS meter supplied as above in FREE carry case 970 201 Model 970 DO 2 meter supplied with DO 2 probe, spare membranes and KCl, zero salts and instructions 970 271 Model 970 DO 2 meter supplied as above in FREE carry case All models are supplied with batteries fitted. 1

ortable ph, Conductivity & DO2 Meters Technical Specifications Enterprise model 430 - Combined ph/conductivity ph (1 or 2 point calibration) Range: 0 to 14 ph Resolution: 0.01 ph Accuracy: ±0.02 ph Conductivity Ranges: 5 switched ranges 0 to 19.99μS - 0 to 199.9mS Resolution: 0.01μS, 0.1μS, 1μS, 0.01mS, 0.1mS Accuracy: ±0.5% ±2 digits TDS Ranges: 5 switched ranges 0 to 19.99mg/l - 0 to 199.9g/l Resolution: 0.01mg/l, 0.1mg/l, 1mg/l, 0.01g/l, 0.1g/l Accuracy: ±0.5% ± 2 digits Temperature Ranges: -9.9 to +99.9 C/14 to 212 F Resolution: 0.1 C / 1 F Accuracy: ± 0.5 C / ± 1 F ATC Range: 0 to 99.9 C / 32 to 212 F Manual Temp. Comp.: 0 to 99.9 C / 32 to 212 F Auto buffer recog.: 4, 7, 9.22 & 10.05 (man. override facility) : 2 AA cells Battery life: Typically 100 hours Size: 175(l) x 75(w) x 35(d) mm Weight: 250g 399 241 To offer additional flexibility an Enterprise electrochemical kit is available. The kit comprises the Models 370 ph meter, the 470 Conductivity meter and the 970 DO2 meter supplied in a custom designed carrying case. Accessories included are an epoxy combination ph electrode, ATC probe, buffer sachets, conductivity cell with ATC, DO2 probe, spare membranes & KCl, zero salts, batteries (fitted) and instruction manuals. 2

ortable ph, Ion, Conductivity & DO2 Meters Premier Range Waterproof to IP67 Full interfacing capability Language options Designed and constructed to resist the harshest of field, laboratory and industrial environments. The whole system is waterproof to IP67, and if dropped into Menu driven operation CE & G.L.P. compliant Auto shut-off feature water will float. These products are ideal for on-site water quality measurement in a multitude of customer applications. Order Code 538 001 Model 3150 ph meter supplied with ph/temperature probe (027 227), ph 4 & 7 buffers, batteries and manual 539 501 Model 3205 Ion meter supplied with ph/temperature probe (027 227), ph 4 & 7 buffers, detachable electrode lead (013 161), waterproof to BNC lead (538 014), batteries and manual 553 001 Model 4150 Conductivity meter supplied with epoxy cell with ATC (K=1) (027 233), batteries and instruction manual 540 001 Model 4200 Conductivity meter supplied with epoxy cell with ATC (K=1) (540 520), batteries and instruction manual 557 001 Model 9150 DO 2 meter supplied with DO 2 probe (541 520), spare membranes and KCl, zero powder, membrane cover, membrane protective cap, batteries and manual 541 001 Model 9200 DO 2 meter supplied with DO 2 probe (541 520), spare membranes and KCl, zero powder, membrane cover, membrane protective cap, batteries and manual 3

ortable ph 350/370/3150 & 3205 Technical Specifications Enterprise models 350 & 370 350 370 ph range -2 to 16.00pH -2 to 16.00pH Resolution (Accuracy) 0.01pH (±0.02pH) 0.01pH (±0.02pH) mv (Abs & Rel) range - ±1999mV Resolution (Accuracy) - 1mV (±1mV) Temperature ranges - -10 to +105 C / 14 to 221 F Resolution (Accuracy) - 0.1 C/1 F (±0.5 C/±1 F) ATC range - 0 to 100 C Common Specifications Manual Temp. Comp. 0 to 100 C / 32 to 212 F Resolution 0.1 C/1 F Auto Buffer Recognition 4.00, 7.00, 9.22 & 10.05 (manual override) Calibration User selectable 1 or 2 point 2 AA cells 175(l)x75(w)x35(d) mm / 250g Premier models 3150 & 3205 ph (1 or 2 point cal) Range -2 to 16.00pH Resolution (Accuracy) 0.01pH (±0.02pH) mv (Abs & Rel) range ±1999mV Resolution (Accuracy) 1mV (±1mV) Temperature ranges -10 to +105 C / 14 to 221 F Resolution (Accuracy) 0.1 C/1 F (±0.5 C/±1 F) ATC range 0 to 100 C Auto Buffer Recognition 4.00, 7.00 & 10.05 (manual override) Calibration ph User selectable 1 or 2 point Concentration Multipoint 1 to 5 points (3205) Activity 1x10-9 to 9.99x10 9 (int. or exp.) (3205) Concentration units activity, %, ppm, mg/l, moles & none (3205) Dedicated ion Ammonium, Calcium, Chloride, Fluoride & Nitrate (3205) Clock 24 hour, hrs/min/sec or day of month/month/year, leap year corrected (3205) 3 AA cells 200(l)x80(w)x60(d) mm / 370g 4

ortable Conductivity 470/4150 & 4200 Technical Specifications Enterprise model 470 Conductivity ranges 6 switched ranges 0 to 19.99μS - 0 to 1999mS* Resolution (Accuracy) 0.01μS to 1mS* (±0.5% ± 2 digits) TDS ranges 6 switched ranges 0 to 19.99mg/l 0 to 1999g/l* Resolution (Accuracy) 0.01mg/l to 1g/l* (±0.5% ±2 digits) Temperature range -10 to +105 C / 14 to 221 F Resolution (Accuracy) 0.1 C/1 F (±0.5 C/±1 F) ATC & Manual ranges 0 to 100 C/32 to 212 F Cell constant Digitally settable 0.015 to 19.99 Reference temperature 25 C Temperature coefficient 0.00 to 4.00%/ C linear Auto standard recognition 10μS, 84μS, 1413μS or 12.88mS (manual override) Probe input Mini-DIN conductivity/temperature 2 AA cells 175(l)x75(w)x35(d) mm / 250g * only with cell constant >5 Premier models 4150 & 4200 Conductivity ranges 5 switched ranges 0 to 19.99μS - 0 to 199.9mS Resolution (Accuracy) 0.01μS to 0.1mS (±0.5% ± 2 digits) TDS ranges 5 switched ranges 0 to 199.9mg/l Resolution (Accuracy) 0.01mg/l to 1g/l (±0.5% ±2 digits) Resistivity range 0 to 20Mohms (4200) Resolution (Accuracy) 0.01Mohms (±0.5% ±2 digits) Salinity range 0 to 99.9g/l (4200) Resolution (Accuracy) 0.1g/l (0 to 35 ±1 / 35 to 99 ±3 of reading) Temperature range -10 to +105 C / 14 to 221 F Resolution (Accuracy) 0.1 C/1 F (±0.5 C/±1 F) ATC & Manual ranges 0 to 100 C/32 to 212 F Cell constant Digitally settable 0.015 to 19.99 Reference temperature 18, 20, 25 C Temperature coefficient 0.00 to 4.00%/ C linear Auto standard recognition 10μS, 84μS, 1413μS or 12.88mS (manual override) Clock 24 hour, hrs/min/sec or day of month/month/year, leap year corrected (4200) 3 AA cells 200(l)x80(w)x60(d) mm / 370g 5

ortable Dissolved Oxygen 970/9150 & 9200 Technical Specifications Enterprise model 970 DO 2 ranges -5 to 199% -5 to 25.0% -5 to 19.99mg/l Resolution 1%/0.1%/0.01mg/l Accuracy ±2% within 10 C of calibration temperature Temperature range -10 to +105 C / 14 to 221 F Resolution (Accuracy) 0.1 C/1 F (±0.5 C/±1 F) ATC & Manual ranges 0 to 60 C/32 to 140 F 2 AA cells 175(l)x75(w)x35(d) mm / 250g Premier models 9150 & 9200 DO 2 ranges 0 to 199%, 0 to 25%, 0 to 19.99mg/l Resolution 1%/0.1%/0.01mg/l Accuracy ±2% within 10 C of calibration temperature Temperature range -10 to 60 C / 14 to 140 F Resolution (Accuracy) 0.1 C/1 F (±0.5 C/±1 F) ATC range -10 to +60 C/14 to 140 F Clock 24 hour, hrs/min/sec or day of month/month/year, leap year corrected (9200) 3 AA cells 200(l)x80(w)x60(d) mm / 370g email: sales@jenway.com 6

ortable Electrochemicals - Accessories Enterprise range Models 350 & 370 ph 033 267 Carry case (model 350) 033 268 Carry case (model 370) Model 470 Conductivity/TDS 033 269 Carry case Model 430 Conductivity/pH 033 268 Carry case Model 970 DO 2 033 270 Carry case Premier range Models 3150 & 3205 ph / Ion 033 162 Carry case 027 229 Reference electrode with ATC Models 4150 & 4200 Conductivity 033 174 Carry case Models 9150 & 9200 DO 2 033 175 Carry case 541 620 B.O.D. probe

Thank you for reading this data sheet. For pricing or for further information, please contact us at our UK Office, using the details below. UK Office Keison Products, P.O. Box 2124, Chelmsford, Essex, CM1 3UP, England. Tel: +44 (0)330 088 0560 Fax: +44 (0)1245 808399 Email: sales@keison.co.uk Please note - Product designs and specifications are subject to change without notice. The user is responsible for determining the suitability of this product.