VON HRTOP eschreibung escription min. 200 cm max. 600 cm 0 min. 200 cm max. 600 cm Terrace pavilions comprising a continuous cubic frame (extruded aluminium profile dimension 230 x mm) and a lamella canopy. The construction is supported by 4 profiled supports (dimensions x mm). Numerous possible foot bracket options round out the system. The frame can be fastened directly to a structure, thereby permitting wall or ceiling mounting (with additional angle brackets). The water runs off through a circular gutter integrated in the frame, where the water flows in via the lamellas. The gutter can be drained into the supports via drainpipes. The lamellas can be swivelled steplessly to a maximum of, which ensures optimum setting of the desired light conditions. The lamella roof protects against rain when closed. In the slightly opened position, a heat build-up is prevented by the bio-climatic air circulation, thereby ensuring a pleasant climate. Wind resistance: The system satisfies wind resistance class 4 when extended (tensioned fabric) or to 150 km/h when retracted. (IN 13561 compliant). Snow load: The system is able to withstand a snow load of up to 110 kg/m 2 rive: Operated via a low-noise electric cylinder with mechanical limit stop. 24 V supply, IP66 protection class. The cylinder opens and closes the lamellas via a carrier profile. Option: rainage: Optionally, the water can be drained through the foot brackets into the floor or with lateral recess at the support. 1 water run-off is required for lamellas with a surface area of 17 m 2, and 2 run-offs for a surface area up to 36 m 2. Integrated LE lighting: Up to three lamellas (freely-selectable position) with light can be retrofitted. The lamella profile has a groove for the integrated lighting, into which an LE strip (warm white colour temperature) is installed. This groove is covered by a plastic reflector profile. The lighting can be switched on and off or dimmed via an external light switch/dimmer. Remote switching on/ off and dimming is possible. daptive LE lighting: triangular aluminium LE profile can be hung on the built-in gutter on the frame profile. The integrated LE strip light (colour temperature warm white) is covered by a reflective plastic profile. Flexible assembly allows you to choose either direct or indirect illumination. The lighting can be turned on and off or dimmed via an external light switch/dimmer. It is also possible to switch the lighting on and off or dim it via remote control. Glazing: The full glass sliding system SV1020 can be used for side glazing. The maximum side surface area of 15 m 2 per side must not be exceeded. I.S.L.. oncept: Via specific connection fittings, the supports can be mounted in the corners of the frame profiles on flooring system S4700. METHO OF ELIVERY Guides pre-mounted in carrier, supports and remaining single parts loose, no fixtures 7.1
VON HRTOP Side and support position 4 4 1 3 1 3 2 2 View / min. 2000 max. 6000 min. 1000 max. 3000 2400 230 (Standard) 130 / = Total width / = Total projection 7.2
VON HRTOP View / (simple construction) min. 2000 max. 4000 230 57 130 min. 1000 max. 3000 2400 (Standard) S4700 ssembly on system flooring View / (double construction) min. 4001 max. 6000 230 130 57 57 min. 1000 max. 3000 2400 (Standard) S4700 ssembly on system flooring 7.3
VON HRTOP Section - Lamellas closed (0 degrees) Lamellas open (45 degrees) Lamellas open to maximum ( degrees) Possible drive positions Position M1 / M2 / M3 / M4 possible / = Total width / = Total projection 7.4
VON HRTOP Possible drive positions Position M1 + M2, or M3 + M4 possible TP313 Foot plate (Standard) 67.25 250 20 210 20 250 20 210 20 / 67.25 / 67.25 7.5
VON HRTOP TP319 Foot plate (orner) / 64.5 180 30 120 30 30 120 30 180 64.5 / 64.5 TP314 Foot plate (Floor system S4700) / S4700 / 7.6
VON HRTOP TP314-1 Foot plate (alustrade) / / TP314-1 / TP314-1 Foot plate (Hole pattern) 48.6 48.6 43.55 44.25 27.75 43.55 26.25 38.25 21.25 16.75 1.8 48.6 44.25 43.55 21.25 38.25 18.25 16.75 1.8 48.6 43.55 27.75 26.25 3 7.7
VON HRTOP ssembly (an Wand) 61 230 ø10.5 ø25 50 61 54 ssembly (superior) 61 ø10.5 ø25 50 230 61 54 7.8
VON HRTOP ssembly (suspended) 61 230 ø10.5 ø25 50 61 54 7.9
VON HRTOP Wall connection variants with 2 support 2 3 2 3 1 2 1 1 2 2 1 2 4 1 4 1 4 1 4 1 3 4 3 4 3 4 7.10 2 3
VON HRTOP orner connection on two long walls with 1 support 2 2 Wall connection on a shortened wall with 3 supports min 800 min 800 3 4 1 2 1 2 orner connection on two short walls with 3 supports min 800 min 800 min 800 3 min 800 3 1 2 1 2 7.11
VON HRTOP Wall connection mounting (long wall) Lateral profile with gutter TP310 68.5 30 X X 30 68.5 476-651 476-651 230 10.5 25 TP310 End profile with gutter TP318 68.5 30 X X 476-651 476-651 30 68.5 230 10.5 25 TP318 68.5 30 X X 30 68.5 476-651 476-651 Total width ( / ) Total projection ( - ) 10.5 X = 2000-2100 mm 601 25-635 mm 4 230 Holes Piece 2201-2800 mm 476-651 mm 5 2801-3400 mm 521-641 mm 6 3401-4100 mm 534-651 mm 7 4101-4700 mm 558-644 mm 8 4701-5400 mm 563-651 mm 9 5401-6000 mm 579-645 mm 10 7.12
VON HRTOP Wall connection mounting (short wall) Lateral profile with gutter TP310 (left / right) Y = min. 500-650 68.5 30 X X X 68.5 155 155 155 230 10.5 25 TP310 End profile with gutter TP318 (left / right) Y = min. 500-650 68.5 X X X 30 68.5 155 155 155 230 25 10.5 TP318 Total width ( / ) Total projection ( - ) X = Holes Piece Y = 2000-2500 mm 155 mm 3 500 2501-4100 mm 155 mm 4 650 4101-6000 mm 155 mm 4 650 7.13
VON HRTOP rainage 4 3 1 2 W3, W4 = from the side of the support W5 = through the support below Not possible to combine with system flooring S4700 rainage large 50 10 45 60.5 60.5 45 rainage small 18 50 ø46.2 10 18 86 15 40 60.5 60.5 40 For the small drainage gutter, two water outlet holes per support are always required 15 86 0 17 m 2 lamella surface one drain 17 36 m 2 lamella surfaces two drains 7.14
VON HRTOP rainage P734 P735 P733 P730 P732 0 17 m 2 lamella surface one drain 17 36 m 2 lamella surfaces two drains TP317-2 Electrical corner cover (Wall connection) 34.4 34 P8 P6 11 11 225 P9 P7 11 7.15
VON HRTOP Power supply line P3, P4 = from the side of the support P5 = through the support below Not possible to combine with system flooring S4700 11 11 34 81.5 55 ø10 55 7.16
VON HRTOP Lamella lighting SL100 Up to 3 illuminated lamellas for a single system. Up to 6 (2 x 3 illuminated lamellas) for a double system. LE Strips SL - SL135 Total width = Lenghts LE Strips = 200 250 300 350 400 cm 150 200 250 300 350 cm SL SL120 SL125 SL130 SL135 1 x 12W = 12W 2 x 12W = 24W 3 x 12W = 36W 1 x 16W = 16W 2 x 16W = 32W 3 x 16W = 48W 1 x 20W = 20W 2 x 20W = 40W 3 x 20W = 60W 1 x 24W = 24W 2 x 24W = 48W 3 x 24W = 72W 1 x 28W = 28W 2 x 28W = 56W 3 x 28W = 84W 12W LE strips inclusive 600 cm Electrical cable 12W 12W 16W 16W 16W 20W 20W 20W 24W 24W 24W 28W 28W 28W 7.17
VON HRTOP Gutter illumination SL300 direct indirect LE Lighting SL315 - SL355 Total projection = Lenghts LE Lighting = 200 250 300 350 400 450 500 550 600 cm 150 200 250 300 350 400 450 500 550 cm SL315 SL320 SL325 SL330 SL335 SL340 SL345 SL350 SL355 2 x 12W = 24W 2 x 16W = 32W 2 x 20W = 40W 2 x 24W = 48W 2 x 28W = 56W 2 x 32W = 64W 2 x 36W = 72W 2 x 40W = 80W 2 x 44W = 88W 12W 12W 16W 16W 20W 20W 24W 24W 28W 28W 32W 32W 36W 36W 40W 40W 44W 44W 7.18
VON HRTOP Exploded view TP311 TP312 TP308 TP328 TP309 TP305 TP329 TP304 TP306 TP315 TP325 TP710 TP324 TP302 TP301 TP318 TP303 TP710 TP310 TP321 TP317-1 TP323-2 TP307 P713 TP316 TP313 TP319 TP314 7.19
VON HRTOP omponents list TP301 Holder rive Fittings TP302 arrier fittings TP303 arrier profile 400 cm 600 cm TP304 for TP311 Fittings for lamella 2 with hole TP305 for TP311, TP312 Fittings Lamella Plastic TP306 for TP312 Fittings for lamella 2 without hole TP307 rip tray fittings (with support) TP307-1 rip tray fittings (without support) TP308 ompensation profile, short 400 cm TP309 ompensation profile, long 400 cm TP310 Lateral profile with gutter 400 cm 500 cm 600 cm TP311 Lamella with light 300 cm 400 cm TP312 Lamella without light 300 cm 400 cm TP313 Foot plate fitting (Standard) TP314 Foot plate fitting (Flooring system covered mounting) TP314-1 Foot plate fitting (Flooring covered mounting) TP315 entre profile with gutter 400 cm 600 cm TP316 Post profile 300 cm TP317-1 orner cover (with supports) 227.5 mm TP317-2 orner cover (Wall connection) 225 mm TP318 End profile with gutter 400 cm 500 cm 600 cm TP319 Foot plate fitting (orner) TP320 Motor drive TP321 for TP317-. End cover fitting TP323-2 orner connection set (with supports) TP323-3/1 for corner 1 / 3 orner connection set TP323-4/2 for corner 2 / 4 orner connection set TP324 rive-cover fittings TP325 for TP315 Fittings for centre profile TP328 for TP308 over fittings for compensation profile, short TP329 for TP309 over fittings for compensation profile, long 7.20
VON HRTOP TP332 Lamella fastening fittings TP333 Fixing angle set (ceiling, mounted assembly) 400 cm 500 cm 600 cm TP710 for TP310 Guide profile 500 cm 600 cm TP727 for TP311 Internal cover profile 300 cm lm P703 for P713 Hose clip P713 Hose lm S359 V plastic cover EZ602/150 EZ602/200 EZ602/250 EZ602/300 Plastic cover 150 cm 200 cm 250 cm 300 cm EZ6060 EZ6061 EZ6062 on/to Radio RTS Radio io Insert drive EZ6063 EZ6064 EZ6065 EZ6066 on/off 90W on/off 120W Radio io 90W Radio io 120W Insert illumination EZ6071 EZ6072 EZ6073 on/off Radio RTS Radio io Insert 2 drive SL SL120 SL125 SL130 SL135 LE strips inclusive 600 cm Electrical cable 150 cm 200 cm 250 cm 300 cm 350 cm SL315 SL320 SL325 SL330 SL335 SL340 SL345 SL350 SL355 SL300 LE lighting complete 150 cm 200 cm 250 cm 300 cm 350 cm 400 cm 450 cm 500 cm 550 cm 7.21
VON HRTOP TP301 TP306 TP310 TP302 TP307 TP311 TP303 TP307-1 TP312 TP304 TP308 TP313 TP305 TP309 TP314 7.22
VON HRTOP TP314-1 TP318 TP323-3/1 TP315 TP319 TP323-4/2 TP316 TP320 TP324 TP317-1 TP321 TP325 TP317-2 TP323-2 TP328 7.23
VON HRTOP TP329 P703 EZ6063 - EZ6066 TP332 P713 EZ6071 - EZ6073 TP333 S359 SL - SL135 TP710 EZ602/... SL315 - SL355 TP727 EZ6060 - EZ6062 7.24