Operating Instruction Manual for Instrument Panel IT 992 Art.-Nr Page 1 / 5

Similar documents
Operating Instruction Manual for Energy Management System EBL 99 C, Art.-Nr Seite 1 / 7

Operating Instruction Manual of Energy Management System EBL 208, Art.-No Seite 1 / 7

Instruction manual. 0 manual for LT A control and switch panel. Table of contents

Instruction manual. Electrobloc EBL 269

Instruction manual. 0 Manual Control and Switch Panel DT 201 B. Table of contents

Instruction manual. Electrobloc EBL 109-6

Instruction Manual. Electrobloc EBL 40 B

Instruction manual. CSV 402 caravan power supply. Table of contents

Operating Instructions

Instruction Manual. Caravan Charging System CSV 404. Table of contents

Instruction Manual. Control and Display Panel DT 220 C. Table of contents

Installation instructions. Adapter AD 01 AD 02 AD 03

User Manual Digital Energy Uninterruptible Power Supply ML Series UPS VA GE Digital Energy Power Quality

User Manual. Digital Energy Uninterruptible Power Supply ML Series UPS VA. GE Digital Energy Power Quality. GE imagination at work

Phocos CML-V2. Solar charge controller. User Manual (English) Dear customer,

Instruction Manual. Electroblock EBL 119 EBL 119 with OVP. Table of contents

1,000,000 Rechargeable Spotlight

TRADE PRODUCTS. Electronic systems for recreational vehicles Supplying controlling indicating

Battery Charger. Series EASY Charger. User s manual

MP V 8A Electronic Smart Charger. Instruction and Information Manual

Usage Instructions of Solar Control for 3Way-Ball Valve

Match 19" GE Digital Energy. Uninterruptible Power Supply VA. Technology for the Digital World. Match 19" UPS.

Technical Manual Electrical Power Supply System T4002

Installation and Operating Instructions for ROBA -takt Switch Gear Type

HST-BL-2830MS & HST-BL-2830MS-USA

Battery Charger Series EASY Charger

Safety. Operating instructions Solenoid valve for gas VG 6 VG 15/10 DANGER. Contents WARNING CAUTION. Changes to edition 07.15

Your new LM controller is a state-of-the art device which was developed in accordance with the latest

SPARKSCAN1 HIGH VOLTAGE CLAMP OPERATING MANUAL

Installation and Connection: Installation and Operating Manual

TURBOTRONIK NT 151/361

RS-3 PRO RS-1007 PRO. CAT IV Analog Clamp meter Series. Users Manual. For detailed specifications and ordering info go to

MB V 3-IN-1 JUMP STARTER WITH SPIRAL WOUND BATTERY

SECTION 1 3 INSTRUMENTS AND CONTROLS. Gauges, meters and service reminder indicators

AQUATEC R / AQUATEC F / AQUATEC XL. Bathlift Operating instructions

HQ-INV300WU-12 HQ-INV300WU WATT DC TO AC MODIFIED SINEWAVE INVERTER WITH USB OUTPUT

Ulyser Component Maintenance Manual

SOLN1 25 V2 Quick Start User Guide & Operating Recommendations

Battery Jump Pack. Instruction Manual for P/N Lithium Iron Phosphate (LiFePO4)

Safety Precautions. Damages resulting from failure to observe these safety precautions are exempt from any legal claims whatever.

Relay Retrofit Program Cutting Tool Safety Guide

Installation and Operating Instructions Magnetic Vibrator MR 1

100 Watt Power Inverter + USB INSTRUCTION MANUAL HT8710-AUOXY

User s Manual. ClipperCreek, Inc. Innovative Infrastructure for Electric and Hybrid Vehicles. Model PCS-15

c-go 24V/6A 24V/8A 24V/12A

EC225 Power Control System

TIC 300 PRO. Users Manual Mode d emploi Bedienungshandbuch Manual d uso Manual de uso. Non Contact AC Voltage Detector. High Energy Tic Tracer

Operating instructions Solenoid interlock TKM/TKF. 1. About this document. Content

Instruction Manual. Caravan Charging System CSV 414. Table of contents

PY-11 Voltage & Continuity Tester

Operating Instructions

5 IN 1 JUMP START OPERATION & MAINTENANCE INSTRUCTIONS MODEL NO: JS5IN1 PART NO: LS0810

Battery Booster Pack. Instruction Manual for P/N

LM-100 LM-120. Light Meters. Users Manual. For detailed specifications and ordering info go to

PS Bedienungsanleitung. Symbole 3. D PowerStarter 7. GB PowerStarter 15. E PowerStarter 23. F PowerStarter 31.

Installation and Operating Manual

Safety. Operating instructions Solenoid valve VGP DANGER. Contents WARNING CAUTION. Changes to edition Elster GmbH Edition 10.

TX900. Microwave Leakage Detector. 99 Washington Street Melrose, MA Phone Toll Free

Operating instructions Switching cushion with safety function SSG-SK. 1. About this document. Content

CORDLESS COMPRESSOR WITH SPOTLIGHT + JUMP START

Operating instructions Safety sensor EX-CSS About this document. Content. 7 Disassembly and disposal 7.1 Disassembly Disposal...

innovations in battery charging

User Manual Rittal PMC UPS 6kVA

Instruction manual Electric glass door lock Touch-to-open

MULTI-FUNCTION POWER PACK

INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS FOR NEW YORK 18 WATT SERIES

JUMP STARTER OPERATION & MAINTENANCE INSTRUCTIONS MODEL NO: JSM350 PART NO: ORIGINAL INSTRUCTIONS LS1117-ISS 1

MPC-B2800 User manual Maxell Rechargeable Power Bank MPC-B2800

General Information This Checking Procedure contains the diagnosis of the following electronic system:

Frequently Asked Questions (FAQ)

PURE SINE WAVE DC TO AC POWER INVERTER

AC50A. Leakage Clamp Meter. User Manual. For detailed specifications and ordering info go to


400 Watt Backup Power System Owner s Manual

KMP Insulation-Continuity Tester. Users Manual

BV-10D. Manual. Regulated DC power supply

PROTECTGLOBAL.COM TROUBLE SHOOTER

Automatic Battery Charger Switching mode with Micro-controlled Input: Vac / Output: 12Volt DC

OPERATOR'S MANUAL IMPORTANT SAFETY INSTRUCTIONS

HOME BOX EV CHARGING STATION WITH FIXED CABLE

Operating instructions Safety sensor BNS About this document. Content. 6 Disassembly and disposal 6.1 Disassembly Disposal...

OPERATING MANUAL. Wind / Solar Hybrid - Charge Controller 24V 1000w. i/hcc Charge Controller

Installation instructions BasicRelay CR / / 2012

Operating instructions Solenoid interlock EX-AZM About this document. Content

Series P215PR Direct Mount Pressure Actuated Condenser Fan Speed Controllers For Single Phase Motors (incl. built-in RFI suppression filter)

Quick Setup Guide for IntelliAg Model YP

Quick Setup Guide for IntelliAg Model YP Twin Row

Model NTX7 Series Automatic Battery Charger User s Manual Rev. 1.0 October 17, 2006

JUMP STARTER OPERATOR S MANUAL RA1900

1200W INVERTER GENERATOR

USER MANUAL GEBRUIKSAANWIJZING. Phoenix 12/150 Phoenix 24/150 Phoenix 48/150

SMT. Installation and Operation Manual. Model:SMT WITH MPPT TECHNOLOGY

Fixed-Mounted Circuit-Breaker Switchgear Type NXPLUS up to 40.5 kv, Gas-Insulated

Automatic Battery Charger Switching mode with Micro-controlled Input: Vac / Output: 12Volt DC

SCOPELITE TIMING LIGHT OPERATING MANUAL

General Precautions. Personnel Precautions

TA-05/C. Instruction and Operation Manual. valid for art.-no.: F-TA-05/C-ISO. (start at modification No. 1601)

Operating instructions Accu Jet

TIME-10 Process Control Stopwatch

Operating instructions

Transcription:

Art.-Nr. 930.420 Page 1 / 5 Contents 1. Description 2. Safety Infmation 3. Operating Instructions and Display 4. Transpt, Stage, Installation 5. Electrical Installation 6. Power-Up, Maintenance 7. Enclosure 1. Description The instrument panel IT 992 is used to control the electrical functions of the living-room area. It is part of a system consisting of a EBL with charging unit, complete 12V distribution and alternatively rod tank senss tank senss f filling level measurement of the water tanks. Filling level measurement has exclusively been designed f plastic tanks. 1.1 Suitable Accessies (not supplied) energy system EBL 99 and it's models and 1x panel cable, 9 x 0,5 rod tank senss 2x rod tank sens and 2x seal ring, art.nr. 126.007 (possibly 2x checknut, art.nr. 102.109) 2x sens cable 5 x 0,5 tank senss 10x tanksens, art.nr. 933.663 2x senscable 5 x 0,5 1.2 Technical Data operating voltage sizes front panel colour 2. Safety Infmation 12V (10-14.5V), power supply by energy management system 110 x 304 x 45 incl. connects (H x W x D in mm) aluminium, powder painted see enclosed table of measurements * The electrical installation of the mothome has to be in accdance with current DIN, VDE and ISO regulations. Manipulations will endanger the safety of persons and the vehicle. Due to the above mentioned regulations and safety rules, manipulations are therefe prohibited. * The instrument panel IT 992 must not be modified. * The connection of the instrument panel has to be done by qualified personel only. * In the following text special notice should be paid to the signs shown below: CAUTION Electrical current hazard warning. CAUTION General hazard warning. 3. Operating Instructions and Display 230V Mains-Supply Indicat If yellow LED '230V~' lights up the energy system is connected to mains supply. See user's manual of energy system, section 6.1 'To Put Into Operation'.

Art.-Nr. 930.420 Page 2 / 5 Turn on and off 12V supply of living area actuate switch with 12V symbol...... in direction of fi 12V supply of living area is turned on. Green indicat lamp is on.... in direction of fi 12V supply of living area is turned off. Green indicat lamp is off. Note: The circuits heater, reserve output 4, base light/automatic step are not switched by 12V main switch. They are operative even if 12V supply is switched off. Only after a energy system shut-down by the battery cut-off switch after a battery change do this circuits need to be switched on by actuating 12V-main switch once. Caution Inquiry of battery voltage To avoid unnecessary discharge of the camping battery the 12V supply should be switched off when leaving the vehicle. Continous indication of battery voltage from 10 to 15 Volts by 'V / Tank'- instrument (upper scale). Automatic illumination when used. Actuate switch in direction of fi Starter battery voltage is indicated. Actuate switch in direction of fi Camping battery voltage is indicated. 3.1 Evaluation of 'Battery Voltage' battery voltage 11.0V 11.1V to 13.2V 13.3V to 13.7V 13.8V to 14.4V... is parked, without mains supply, runs on battery no load: battery discharged on load: battery possibly overloaded caution: low-level discharge standard operation if at rest * it goes approx.: <12V: battery discharged >12.8V: battery full is allowed to happen only right after driving on mains supply impossible vehicle...... is driving, mobile no charge caution: low-level discharge bad charging (if f longer time) battery is being charged battery is being equalize charged... is connected to mains supply, runs on 230V no charge caution:low-level discharge bad charging (if f longer time) battery is being charged battery is being equalize charged >14.6V impossible battery is being overloaded: battery is being overloaded: regulat of alternat charger defective defective * battery at rest means: The camping battery was not used f several houres. Possibly check voltage in the mning without any load. If battery voltage at rest is <12.0V it might be totally discharged Caution Battery Damage Low-level discharge might permanently damage the battery.

Art.-Nr. 930.420 Page 3 / 5 Red warning indicat ' Alarm' blinks Optical warning at alarming low camping battery charge. As soon as the camping battery voltage drops below 11.0V the red warning light 'Alarm' starts blinking. Any load should now be switched off immediately and the camping battery has to be recharged. If camping battery voltage continues to sink and drops below 10.5V, the battery monit module of the EBL switches all 12V load off. See section 3.1 'Battery Voltages' and the respective sections of the EBL 'Battery Charge' and 'Battery Monit Module'. Display of charging current and discharging current of camping battery The charging and discharging current of the camping battery is displayed permanently by the STROM'- meter. The current meter is automatically illuminated by using the battery voltage- filling level instrument. Continous reading of indicating range from 30A discharge current (red range) to no current (mid range) to 30A charging current (green range). Evaluation of charging and discharging currents vehicle...... is parked,... is driving, current reading without mains supply, runs on battery mobile red on load, no charge range discharge of battery too much load alternat defective 0 A no load battery fully ( nearly) charged if charging current decreases with no load (except refrigerat) from green range to zero green range only possible with solar-power supply Inquiry of water tank filling level battery is being charged, up to over 30A possible... is connected to mains supply, runs on 230V no charge too much load alternat defective battery fully ( nearly) charged if charging current decreases with no load from green range to zero battery is being charged, up to 16A possible (with additional charger up to 32A) Indication of water tank filling levels by 'V / Tank'-meter (lower scale) in steps of empty, 1/4, 1/2, 3/4 and full. Automatic illumination of the meter during inquiry. Actuate switch in direction of ' fi Filling level of fresh water tank is shown Actuate switch in direction of fi Filling level of waste water tank is shown Note: Inquiry of watertank filling levels is f tempary use only. The utilized method of measurement is not suitable f continous running prolonged inquiries. Caution Continous running prolonged testing will damage rod tank senss tank senss. Note: If the mot home is not on mains supply the power supply of the water pump should be turned off during extented periods of no use (eg. at night) as the pump relay has a load current of approx. 160mA. This adds up to about 4Ah battery drain per day. Caution Creepage current discharge of camping battery with pump switch on.

Art.-Nr. 930.420 Page 4 / 5 Switch on and off of awning light Actuate switch in direction of fi Awning light is switched on Actuate switch in direction of fi Awning light is switched off Please see user's manual of mot home manufacturer 4. Transpt, Stage, Installation 4.1 Transpt, Stage * The instrument panel should be sted and transpted in a suitable packing and in dry environment only. * Stage temperature range : - 10 C to + 50 C. 4.2 Installation * The instrument panel is designed f use in dry and sufficiantly ventilated environment within a temperature range of - 10 C to + 45 C. * It is designed to sink into a cabinet front and has to be fitted on to a stout and level surface by use of the six provided location holes. Please refer to enclosed table of measurements f mounting size details. 5. Electrical Installation * Electrical installation of the instrument panel has to be executed by qualified personel only. * Electrical connection on the backside of the instrument panel accding to enclosed connection instructions. 6. To Put Into Operation, Maintenance 6.1 To Put Into Operation * The instrument panel can be operated only in connection with a energy system and water tank filling level measurement accessies. See section 1.1 'Suitable Accessies'. * After complete connection the instrument panel is operated by the EBL. The appliance is put into operation as by following sequence: Connect the EBL to mains supply, switch the battery cut-off switch into 'Ein'-position and actuate 12V main switch on instrument panel. The the yellow LED '230V~' lights up if the energy system is connected to mains supply. See user's manual 6.1 'To Put Into Operation'. 6.2 Maintenance, Malfunctions * The IT 992 is maintenance-free. * F cleaning of the front panel use a soft moisturized cloth with a mild detergent (no methylated spirit, paint- thinner, etc.). Liquids must not be allowed to get into the panel. * Should repairs be necessary, please contact the service department of Schaudt GmbH ph. 0049-(0)7544-9577-16, email: kundendienst@schaudt-gmbh.de * If it is not possible to see the manufacturer f service (eg. being overseas), necessary repairs can be carried out by a qualified wkshop. * Unqualified repairs enfce expiration of warranty. The manufacturer Schaudt GmbH disclaims it's liability and is therefe not liable to resulting damages.

Art.-Nr. 930.420 Page 5 / 5 7. Enclosures To this operating instruction manual belongs the enclosed the connection diagram and the dimension list to IT 992, art. nr. 930.420. This operating instructions manual with all it's enclosures must be delivered together with the IT 992, art.nr. 911.420. It must be part of the instruction manual if it is part of a system installed in a mothome. 7.1 EC declaration of confmity We hereby certify that the type of construction of the instrument panel IT 992 cresponds accdingly to approbiate provisions: Electromagnetic compabitibility guide line 89/336/EWG mit Änderung 92/31/EWG The EC declaration of confmity in iginal is available and can be looked at any time. Manufacturer: Schaudt GmbH, Elektrotechnik & Apparatebau Address: Daimlerstraße 5 88677 Markdf Germany

ALARM 230V 12V IT 992