Gateway Type Serial Transmission System

Similar documents
New Concept Connector Type Manifold

Fieldbus System (Output device for driving 5 port solenoid valves)

SMC guide to ATEX compliant products

SV1000/2000/3000/4000

Base Mounted Metal Seal/Rubber Seal VQ0000 (VV5Q05) VQ1000 (VV5Q11) Individual SUP spacer. Individual EXH spacer

Series ITV1000/2000/3000

D-sub connector. Type 60F. Manifold 1 (P: SUP), 3/5 (R: EXH) Valve stations (With power terminal) D-sub connector

SV F. Series SV SV SZ SYJ. Series EX500 Decentralized Serial Wiring. How to Order Valve Manifold Assembly. How to Order Solenoid Valves

Select from 3 product types and 14 protocols.

Fieldbus System (Gateway Decentralized Type)

Series ITV0000. Compact Electro-Pneumatic Regulator ITV N Q. IITV00 02 n. How to Order. For single unit and single unit for manifold

5 Port Solenoid Valve

Electro-Pneumatic Regulator Electronic Vacuum Regulator

Electro-Pneumatic Regulators. Electronic Vacuum Regulators

Electro-Pneumatic Regulators. Electronic Vacuum Regulators

5 Port Direct Operated Poppet Solenoid Valve, Rubber Seal

5 Port Solenoid Valve Direct Operated Poppet Type. Specifications

Single Valve/Sub-plate Type IP67 Compliant 90-SV Series

Manual override. Non-locking push type (Tool required) Nil: B: Locking type (Tool required) C: Locking type (Manual) Electrical entry

Electro-Pneumatic Regulators. Electronic Vacuum Regulators

Series VZ Port Solenoid Valve Body Ported. How to Order VK VZ VF VFR VP4 VZS VFS VS4 VQ7 EVS VFN Type of actuation. Option.

D-sub Connector. Cassette base manifold SV1000/SV2000 Tie-rod base manifold SV1000/SV2000/SV3000/SV4000

Reduced-wiring Fieldbus System (Serial Transmission)

10 mm. 7.5 mm. 40 mm. 4 Port Solenoid Valve. Series SJ2000/3000 SJ3000 SJ2000. Cassette Type Manifold. Connecter connection

Fluid Internal pilot Operating pressure range (MPa) External pilot Operating pressure range (MPa) 2 position single

VQ1000. How to Order Manifold. Kit type

S Y 3 A F NFZD

5 Port Solenoid Valve Direct Operated Poppet Type. Specifications

Series VZ Port Solenoid Valve Body Ported. How to Order VK VZ VF VFR VP4 VZS VFS VS4 VQ7 EVS VFN. Body ported VZ L

How to Order L B. Pilot type. Nil. U side D side. Stations 3 2 1

I N D E X. VQ1000 How to Order, Manifold Options VQ2000 How to Order, Manifold Options VQ1000/2000 Model, Standard/Manifold Specifications

Series VZ Port Solenoid Valve Body Ported. How to Order VK VZ VF VFR VP4 VZS VFS VS4 VQ7 EVS VFN. Body ported VZ L

3 Port Solenoid Valve Pilot Operated Poppet Type. External pilot

Base Mounted Plug-in Unit

3 Port Solenoid Valve Direct Operated Poppet Type

Option. Nil. 02 to 24 B Note 2) K Note 3) N. Note 1) Cable/SI unit specifications

How to Order Manifold FD2. Manifold mounting. D DIN rail mount style Note) E Direct mount style. Note) C kit of SQ2000 only. Cable specifications

4 Port Solenoid Valve Cassette Type Manifold Rubber Seal

Specifications. Fluid Ambient and fluid temperature ( C)

3 Port Solenoid Valve

Series PCW. PC Wiring System

Electro-Pneumatic Regulator/Electronic Vacuum Regulator

5 Port Solenoid Valve. High speed response type) Series. Body ported VQZ1 2 VQZ2 2 VQZ3 2 VQZ1 5 VQZ2 5 VQZ3 5. Base mounted

Cable Appendix. Valves. Cable Appendix. Page 16. Multi-way cables. D-sub Connector Cables. AXT100-DS Conforming to MIL-C-24308

Manifold Specifications

Series SY3000/5000/7000

ISO Interface. Large capacity. Light weight. Accommodates enclosure IP65. Solenoid Valve (with M Connector) Conforming to ISO

CAT.E152-5 Port Solenoid Valve/Body Ported Cassette Type Manifold. Series SZ3000

5 Port Solenoid Valve

Fieldbus System Variations

Series VP4 50/4 70. Large Size 5 Port Solenoid Valve Rubber Seal SJ SY SY SV SYJ SZ VF VP4 S0700 VQ VQ4 VQ5 VQC VQC4 VQZ SQ VFS VFR VQ7 VP4

5 Port Solenoid Valve

4 Note 1) Value for communications type. (PROFIBUS DP)

5 Port Solenoid Valve

Exhausting equipment for pilot valve not required. Common exhaust port for main and pilot valve (VF1000/3000)

How to Order Manifold. Option Symbol

5 Port Solenoid Valve Series SV

APS & APIS ATEX AIRPOWER SWITCH BOXES FEATURES DESCRIPTION

Base Mounted Series VQZ100/200/300. Nil. W Note) Compliant. Electrical entry. (DC speci- fication) terminal terminal. Coil voltage 24VDC

CAT.E-155 A. Base Mounted Type. Series VQ Port Metal Seal/Rubber Seal Solenoid Valve

Manifold Specifications Stacking Type

2.26 S OLENOID VALVES S ERIES VQ1000

42 Series MAConnect TM. 42 Series Plug-In Manifold

How to Order Manifold. Control unit Refer to pages to Kit/Electrical entry/cable length. kit (D-sub connector) U0 U1 U2

5 Port Pilot Operated Solenoid Valve Metal Seal, Plug-in/Non Plug-in

Series SY3000/5000/7000

Pilot Operated 2 Port Solenoid Valve for Dry Air

Series SJ3A6. Vacuum Release Valve with Restrictor P.86 P.90. D-sub Connector Flat Ribbon Cable PC Wiring Serial Wiring: EX180 Serial Wiring: EX510

5 Port Solenoid Valve

Example. U side. Stations SY5000

5 Port Pilot Operated Solenoid Valve Metal Seal, Plug-in/Non Plug-in. Flow characteristics (1) 1 4/2 (P A/B) 4/2 5/3 (A/B R1/R2)

5 Port Pilot Operated Solenoid Valve Metal Seal, Body Ported. Flow characteristics 1 4/2 (P A/B) 4/2 5/3 (A/B R1/R2)

Rubber Seal VP300/500/700

Conforms to ISO Standard Size 18 mm, 26 mm Plug-in Type. 5 Port Solenoid Valve

5 Port Pilot Operated Solenoid Valve Metal Seal, Body Ported

4/5 Port Solenoid Valve

Series ZSE30/ISE30. High Precision, 2-color Display Digital Pressure Switch 25 M ISE30 01 ZSE M. How to Order. For positive pressure

Plug Lead Unit: Flip Type

5 Port Solenoid Valve

Grommet (G) (Standard) 100 VAC, 50/60 Hz 200 VAC, 50/60 Hz 24 VDC

Flow characteristics Max. (1) b Standard Specifications. P Manual override.

Centralised Control Panel

5 Port Solenoid Valve Plug Lead Type

Series VQZ1000/2000/3000 Single Unit

Pilot Operated 2 Port Solenoid Valve for Dry Air

How to Order Manifold. Kit type L8 B4 B6 B8 LM

Rubber Seal 5 Port Pilot Type/Body Ported Type. Symbol. How to Order

Terminal Block Box (Spring Type) SY3000/5000/7000 Series

5 Port Solenoid Valve

Series ZSE30/ISE30. High Precision, 2-color Display Digital Pressure Switch. With One-touch fittings are newly introduced. PSE

5 Port Pilot Operated Solenoid Valve Metal Seal, Plug-in/Non Plug-in. Flow characteristics (1) 1 4/2 (P A/B) 4/2 5/3 (A/B R1/R2)

ISO Standard Solenoid Valve. Series VQ7-6/7-8. (Size 1) (Size 2) Conforms to ISO Standard 5599/I

Series VKF300 VV061 V100 S070 VQD VKF VK VT VS

1.8 w Port Solenoid Valve Direct Operated Poppet Type. New. Series VT307 CAT.ES11-107A. Power consumption

3 Port Solenoid Valve Direct Operated Poppet Type. Body type. Body ported. Manifold. Valve option

Remote Process Actuation Control System AirLINE - Rockwell 1734 Point I/O System

(Standard) 100 VAC, 50/60 Hz 200 VAC, 50/60 Hz 24 VDC

2-Color Display High-Precision Digital Pressure Switch Series ZSE40A(F)/ISE40A

3 Port Air Operated Valve

5 Port Pilot Solenoid Valve Rubber Seal

Transcription:

P99-EX-B Gateway Type Serial Transmission System P Maximum 8 point control (64 inputs/64 outputs) P Flexibility of manifold valve installation improved with 4 branch wiring

Flexible installation and removal of Uses connector Gateway Type Serial Transmission System A large selection of applicable manifold valves SV Tie-rod type manifold valves VQC Applicable cylinder sizes Tie-rod type manifold product series line-up SV VQC name SV000 SV000 SV000 SV4000 VQC000 VQC000 Cv factor 0. 0. Applicable cylinder size ø40 ø50 ø6 ø80 ø00 ø5 (Load factor: 50%, Cylinder speed: 50mm/s) Cv factor may vary depending on construction of manifold.

manifold valves and input blocks! type junctions. Wiring efficiency improved (wiring labor reduced) The use of connector type cables for all wiring between equipment improves work efficiency and prevents miswiring. Since power supply lines are included in all cables, separate power supplies for SI units (valves) and input devices are unnecessary. Low running cost Low power consumption of 0.6W (SV solenoid valve, 5mA, 4VDC) Service life of 50 million cycles or more (Based on SMC life test conditions.) Connector junctions No complicated wiring Manifold valves and input blocks can be easily installed or removed to accommodate specification changes. Manifold valve Input block IP65 rating All equipment comprising the EX500 series has an IP65 rating, which allows use in environments where there is direct contact with water, etc. (Based on IEC59.) Unused connectors are protected with water proof caps.

Gateway (GW) Unit Total I/O points: 64 inputs/64 outputs 4 branches, with 6 inputs and 6 outputs per branch, allow decentralized control. 6 inputs x 4 6 outputs x 4 Since the communications to each branch unit are separate from the master PLC transmission, there is no need to worry about transmission delay time. Gateway units can be selected for use with remote I/O, DeviceNet and PROFIBUS-DP. PLC 64 inputs 64 outputs 5 Port Solenoid Valve/ SV000, 000 Cassette base manifolds The lever type facilitates easy and reliable installation and removal. Lever Pull the lever forward with a screw driver, etc. DIN rail holding screw Loosen the DIN rail holding screws at both ends, and separate the manifold to the left and right. Pull the valve up at the front. Interchangeable cylinder port fitting assemblies SV000: C, C4, C6, N, N, N7 SV000: C4, C6, C8, N, N7, N9 High speed response: 0ms (SV000, double, 0.5MPa, 4VDC, with surge voltage suppressor) Relay output modules can be installed ( SV000) Equipment up to a maximum of 0VAC, A can be simultaneously controlled together with series SV. Applicable cylinder sizes SV000 SV000 Cv factor Applicable cylinder size ø40 ø50 ø6 ø80 (Load factor: 50%, Cylinder speed: 50mm/s) M8 and M connectors can be used on the same unit One input unit is able to accommodate a variety of input equipment. Input Unit

EX500 Gateway (GW) Unit How to Order EX500 G AB (-X) AB DN PR Network communication protocol Remote I/O (RIO) DeviceNet PROFIBUS-DP RIO compatible Specifications Model Applicable PLC/Communication protocol Communication speed Rated voltage Power supply voltage range Input/Output points Input/Output branches Branch cable Branch cable length Branch communication connector Power supply connector Ambient temperature/humidity Enclosure Compatible standards EX500-GAB-X Rockwell Automation PLC 57.6Kbit/sec 5.Kbit/sec 0.4Kbit/sec EX500-GDN DeviceNet Release.0 5Kbit/sec 50Kbit/sec 500Kbit/sec 4VDC EX500-GPR PROFIBUS-DP 9.6, 9., 9.75, 87.5, 500Kbit/sec.5,, 6, Mbit/sec Input & control unit power supply: 4VDC ±0% Solenoid valve power supply: 4VDC +0%/ 5% (voltage drop warning at approx. 0V) 00mA or less Maximum 64 inputs/maximum 64 outputs 4 branches (one branch 6 inputs/6 outputs) 8 wire heavy duty cable 5m or less (total extension 0m or less) M connector (8 pins, socket) M connector (5 pins, plug) +5 C to +45 C/5% to 85%RH (with no condensation) IP65 UL, CSA, CE Input Units How to Order Input Manifolds How to Order Input Blocks EEX500 IB E 8 (-X) EX500 IE (-X) Input block (M8) Input block (M) Connector type E T M M8 connector M connector M8, M mixed RIO compatible Stations 8 station stations 8 stations 4 Connector type/ Input specification M8 connector/pnp M8 connector/npn M connector/pnp M connector/npn RIO compatible Input unit specifications Current source type input block (PNP input block) Connection block or Current sink type input block (NPN input block) Communication connector M connector (8 pins, plug) Connection block qty. Maximum 8 blocks Block supply voltage 4VDC Block supply current 0.65A Max. 00mA or less (at rated voltage) Operates at ATyp. (power supply cut) Short circuit protection Reset by turning GW unit power off and back on again. When placing an order, the input manifold part number and input block part number are entered together. Cables Input block specifications Compatible sensor Sensor connector Input points Rated voltage Indication Insulation Sensor supply current Current source type (PNP output) or Current sink type (NPN output) M8 connector ( pins) or M connector (4 pins) points 4VDC Green LED None Maximum 0mA/Sensor How to Order Branch Cables with M Connector How to Order Power Supply Connector Cables EX500 AC 00 SSPS EX500 AP 00 S SSPS SAPA Cable length 00 005 00 00 050 0.m 0.5m m m 5m Connector specification Socket side: Straight, Plug side: Straight Socket side: Angled, Plug side: Angled Cable length 00 050 m 5m Connector specification S A Straight Angled 4

5 Port Solenoid Valve/ SV000, 000 EX500 How to Order Cassette Base Manifolds SS5V W6S AW D 05 U C4 Relay output module SV000 SV000 SI unit specification AW AW Remote I/O (RIO) DeviceNet PROFIBUS-DP Valve stations 0 stations 6 6 stations 6 solenoids or less P, R port entry position U D B Pilot specification R How to Order Solenoid Valves U side D side Both sides Internal pilot External pilot SV000 C ø. C4 ø4 C6 ø6 N ø/8" N ø5/" N7 ø/4" DIN rail length Standard length For stations 0 For 0 stations A, B port size (One-touch fitting) SV000 C4 ø4 C6 ø6 C8 ø8 N ø5/" N7 ø/4" N9 ø5/6" SV 00 5F U Relay Output Module Part Number SV000-60-5A-A SV000 SV000 Type of actuation 4 5 Single solenoid Double solenoid Closed center Exhaust center Pressure center Pilot type R Internal pilot External pilot Manual override Light/Surge voltage suppressor U R D Non-locking push type Slotted locking type With light/surge voltage suppressor With surge voltage suppressor Valve specifications position single Operating pressure position double range (MPa) position Enclosure Rated coil voltage Allowable voltage fluctuation Power consumption (W) 0.5 to 0. to 0. to IP65 (based on IEC59) 4VDC ±0% of rated voltage 0.6 (With light: 0.65) SI unit specifications Connection block Connection block stations Block supply voltage Block supply current Communication connector Relay output module Solenoid valve (single, double) Double solenoid valve: Maximum 8 stations Single solenoid valve, Relay output module: Maximum 6 stations 4VDC 0.65A Max. 00mA or less (at rated voltage) M connector (8 pins, socket/plug) Manifold specifications Model Manifold type P(SUP), E(EXH) type Valve stations Port size Valve Cv factor P, E port A, B port P A/B A/B E SV000 SV000 Plug-in type Common SUP, EXH to 6 stations ø8, ø5/6" ø0, ø/8" ø., ø4, ø6 ø4, ø6, ø8 ø/8", ø5/", ø/4" ø5/", ø/4", ø5/6" 0.6 Valve Cv factors are shown for A, B port sizes of C6 for SV000, and C8 for SV000. Relay output module specifications Output points Output type Maximum load voltage Maximum load current Indicator light point output (connector with lead wire/m) 4 pin connector (M) plug Not connected Output connection Not connected Output connection Contact type ["a" (N.O.) contact] 0VAC A Green LED 0mA or less Relay output module pin wiring -6-4 Shimbashi, Minato-ku, Tokyo 05-0004, JAPAN Tel: 0-50-740 Fax: 0-508-480 URL http://www.smcworld.com 000 SMC CORPORATION All Rights Reserved st printing March, 000 D-SMC.L.A. P-50 (OCPC) nd printing September, 000 D-SMC.L.A. P-0 (SP) Specifications are subject to change without prior notice and any obligation on the part of the manufacturer. Printed in Singapore