Pilot Operated 2 Port Solenoid Valve for Dry Air

Similar documents
Pilot Operated 2 Port Solenoid Valve for Dry Air

1.8 w. 3 Port Solenoid Valve. VT307 Series. Direct Operated Poppet Type. Power consumption. A single valve with various valve functions

Series VKF300 VV061 V100 S070 VQD VKF VK VT VS

Series VQ Port Solenoid Valve

3 Port Solenoid Valve

3 Port Solenoid Valve Direct Operated Poppet Type

3 Port Solenoid Valve Direct Operated Poppet Type. Body type. T Body ported O Manifold. Valve option

10 VQ F. Nil Latching type: Push-locking type (Tool required) B. Nil. Electrical entry

5 Port Direct Operated Poppet Solenoid Valve, Rubber Seal

5 Port Solenoid Valve Direct Operated Poppet Type. Specifications

5 Port Solenoid Valve Direct Operated Poppet Type. Specifications

Series VP3145/3165/3185

3 Port Solenoid Valve

3 Port Solenoid Valve Direct Operated Poppet Type 02 1 G VT325. For manifold: Enter VO. Valve option. Nil Standard V For vacuum Option.

Series VZ Port Solenoid Valve Body Ported. How to Order VK VZ VF VFR VP4 VZS VFS VS4 VQ7 EVS VFN. Body ported VZ L

3 Port Solenoid Valve

Fluid Internal pilot Operating pressure range (MPa) External pilot Operating pressure range (MPa) 2 position single

Body width of 10mm, Nl/min (49.08) 2W (Standard) Nl/min (78.52) 4W (U type: Large flow) Vacuum applications possible (up to 100kPa) 3 S.

Series VQZ1000/2000/3000 Single Unit

3 Port Solenoid Valve Direct Operated Poppet Type. Body type. Body ported. Manifold. Valve option

3 Port Solenoid Valve

Non-Contact Sensor for Workpiece Placement Verification

Series VZ Port Solenoid Valve Body Ported. How to Order VK VZ VF VFR VP4 VZS VFS VS4 VQ7 EVS VFN Type of actuation. Option.

5 Port Solenoid Valve. High speed response type) Series. Body ported VQZ1 2 VQZ2 2 VQZ3 2 VQZ1 5 VQZ2 5 VQZ3 5. Base mounted

Vacuum applications possible (up to 100kPa) Base mounted. Cylinder bore size (mm) Series CM2. Pressure: 0.5MPa Load ratio: 50% Cylinder stroke: 300mm

3 Port Solenoid Valve. Copper-free specifications. The fluid contacting section is copper-free and the standard style can be used as it is.

3 Port Solenoid Valve Pilot Operated Poppet Type. External pilot

0.35 W (Without light)

How to Order Manifold FD2. Manifold mounting. D DIN rail mount style Note) E Direct mount style. Note) C kit of SQ2000 only. Cable specifications

How to Order Valve. Body type. Symbol Body type B Base mounted with screws 10 S070 B 5 B G 10 S070 C 5 B G 32. Body type.

5 Port Solenoid Valve

Specifications. Fluid Ambient and fluid temperature ( C)

Series VP4 50/4 70. Large Size 5 Port Solenoid Valve Rubber Seal SJ SY SY SV SYJ SZ VF VP4 S0700 VQ VQ4 VQ5 VQC VQC4 VQZ SQ VFS VFR VQ7 VP4

Series VZ Port Solenoid Valve Body Ported. How to Order VK VZ VF VFR VP4 VZS VFS VS4 VQ7 EVS VFN. Body ported VZ L

VQ1000. How to Order Manifold. Kit type

D-sub connector. Type 60F. Manifold 1 (P: SUP), 3/5 (R: EXH) Valve stations (With power terminal) D-sub connector

Vacuum / Release Unit

0.45 ms. 9mm. High Speed 2 Port Valve. SX10 Series. 2 mounting types

Compact Direct Operated 2/3 Port Solenoid Valve for Water and Air

Series VFR Port Pilot Operated Solenoid ValveRubber Seal, Plug-in/Non

Series SV1000/2000/3000/4000

I N D E X. VQ1000 How to Order, Manifold Options VQ2000 How to Order, Manifold Options VQ1000/2000 Model, Standard/Manifold Specifications

13 msec (at 500 mm )/18.5 msec (at 1000 mm )

Exhausting equipment for pilot valve not required. Common exhaust port for main and pilot valve (VF1000/3000)

5 Port Solenoid Valve

3 Port Solenoid Valve. Copper free No copper used for sections in contact with fluids. N.C. 1(P) 2(A)

Rubber seal 3 Port Pilot Solenoid Valve. Specifications. Fluid Operating pressure range MPa. Internal pilot

Series SYJ300/500/700

Manual override. Non-locking push type (Tool required) Nil: B: Locking type (Tool required) C: Locking type (Manual) Electrical entry

Example. U side. Stations SY5000

5 Port Solenoid Valve

Base Mounted Series VQZ100/200/300. Nil. W Note) Compliant. Electrical entry. (DC speci- fication) terminal terminal. Coil voltage 24VDC

5.0 MPa Pilot Operated 2/3 Port Solenoid Valve & Check Valve

Soft Start-up Valve. AV2000/3000/4000/5000 Series

5 Port Solenoid Valve

Rubber Seal VP300/500/700

High Pressure Coolant Valve

5 Port Solenoid Valve

Series VP3145/3165/3185

5 Port Pilot Operated Solenoid Valve Rubber Seal. Specifications Fluid Operating pressure range (1) Response time 3 position (2) Enclosure

1 1/4 (32A) to 2 (50A) added.

5 Port Solenoid Valve/Direct Poppet. Valve model VK3120. VK3120Y (Low wattage 2W DC) VK3140 VK3140Y (Low wattage 2W DC)

Option. Nil. 02 to 24 B Note 2) K Note 3) N. Note 1) Cable/SI unit specifications

5 Port Solenoid Valve

Grommet (G) (Standard) 100 VAC, 50/60 Hz 200 VAC, 50/60 Hz 24 VDC

Exclusively for air pressure system and air-hydro circuit control

Series SY3000/5000/7000

3 Port Direct Operated Poppet Rubber Seal. Standard Continuous duty Energy saving Vacuum Energy saving/vacuum

3 Port 3 Position Valve

How to Order Manifold. Kit type L8 B4 B6 B8 LM

1.8 w Port Solenoid Valve Direct Operated Poppet Type. New. Series VT307 CAT.ES11-107A. Power consumption

5 Port Pilot Operated Solenoid Valve Rubber Seal, Plug-in/Non Plug-in. Standard Specifications. Fluid Operating pressure range

5.0 MPa Pilot Operated 2/3 Port Solenoid Valve & Check Valve

Compact Proportional Solenoid Valve

2 Port Valve For Compressed Air and Air-hydro Circuit Control. Exclusively for air pressure system and air-hydro circuit control

5 Port Pilot Operated Solenoid Valve Metal Seal, Body Ported

5.0 MPa Pilot Operated 2/3 Port Solenoid Valve & Check Valve

4 Port Solenoid Valve

Indicate VO for manifold. Port size. Nil 1/8 02 1/4. Specifications. Option Description Bracket (With screw) Part no. DXT060-27A

Power Valve: Regulator Valve. Specifications. Model VEX Operation type Fluid Max. operating pressure Set pressure Air operated.

5 Port Pilot Operated Solenoid Valve Metal Seal, Body Ported. Flow characteristics 1 4/2 (P A/B) 4/2 5/3 (A/B R1/R2)

4 Port Solenoid Valve

D-sub Connector. Cassette base manifold SV1000/SV2000 Tie-rod base manifold SV1000/SV2000/SV3000/SV4000

5 Port Solenoid Valve: Base Mounted Metal Seal/Rubber Seal. High speed & Long life. (Metal seal, with light and surge suppressor) 100 million cycles

Power Valve: Regulator Valve. Specifications. Model VEX Operation type Fluid Max. operating pressure Set pressure Air operated.

2 position single 2 position double. 3 position Ambient and fluid temperature ( C) Note 1) 3 position Max. operating

Coolant Valve. Series VNC. Cylinder actuation by pilot air. Wide selection of port size and variations

2 Port Solenoid Valve For Dust Collector

5 Port Solenoid Valve

Coolant Valve. Air Operated/External Pilot Solenoid

Series SYA3000/5000/7000

Q1 Q2 Q3. 2 stage performance. 3 stage performance. Suction flow rate. 250% suction flow rate increase. Release flow rate adjusting needle.

5 Port Solenoid Valve

4/5 Port Solenoid Valve

Cable Appendix. Valves. Cable Appendix. Page 16. Multi-way cables. D-sub Connector Cables. AXT100-DS Conforming to MIL-C-24308

ATEX Compliant 5 Port Solenoid Valve II 2G Ex ia IIC T6 Gb Ta 10 C to 45 C. How to order. Barrier. Electrical entry

5 Port Pilot Operated Solenoid Valve Metal Seal, Plug-in/Non Plug-in. Flow characteristics (1) 1 4/2 (P A/B) 4/2 5/3 (A/B R1/R2)

3 Port Air Operated Valve

Series SY3000/5000/7000

(Standard) 100 VAC, 50/60 Hz 200 VAC, 50/60 Hz 24 VDC

Transcription:

Pilot Operated Port Solenoid Valve for Dry ir VQ0/30 Series Compact and lightweight with large flow capacity [Option] VQ0 Weight (g) 46 80 C [dm 3 /(s bar)].5 (C8) 3.0 (C) Series VQ0 Series VCH VDW SX0 VQ LVM High frequency operation possible High speed response 7 ms or less (VQ0), 0 ms or less () (High speed response type without light/surge voltage suppressor at the supply pressure of 0.5 MPa) Long operating life Easy piping with One-touch Fittings Dusttight low jetproof enclosure (IP65) compliant in DIN terminal type. pplication: ir-blow, Blow-off of workpiece, etc. 53

Pilot Operated For Dry ir Port Solenoid Valve VQ0/30 Series Single Unit [Option] How to Order Valves VQ G C6 Series/ Orifice diameter Symbol 3 Series VQ0 Valve type N.C. (OUT) (IN) When the valve is closed, flow is blocked from port to port. However, if the pressure in port is higher than port, the valve will not be able to block the fluid and it will flow from port to port. Body type : Single unit M: For manifold Coil voltage 00 VC (50/60 Hz) 00 VC (50/60 Hz) 3 0 VC (50/60 Hz) 4 0 VC (50/60 Hz) 5 4 VDC 6 VDC Note ) 9 Other special voltage Note ) Please consult with SMC for special voltages. Note ) There is polarity for DC voltage (with power-saving circuit type). Electrical entry G: Grommet Manual override None Note) Slotted locking type B (tool required) Note) Only normally closed DIN terminal in-line type is applicable. Electricity circuit Symbol DC voltage Port size Symbol Port size C6 C8 C0 C With power-saving circuit (With surge voltage suppressor protection circuit) With power-saving circuit Z (With light/surge voltage suppressor protection circuit) Note) High speed response type H (Without energy-saving, light/surge voltage suppressor circuit) Note) H is available only for DC voltage and cannot be energized continuously. Made to Order Specifications Oil-free specifications VQ 3M Option : None F: With bracket L: Type L (VQ0 only) CE-compliant Q Note) If ordering both options, indicate LF. One-touch fitting for ø6 One-touch fitting for ø8 One-touch fitting for ø0 One-touch fitting for ø X(-Q) CE-compliant Made to Order specifications (Refer to the table below) VQ0 C voltage With full wave rectifier circuit (With surge voltage suppressor protection circuit) With full wave rectifier circuit (With light/surge voltage suppressor protection circuit) Please contact SMC for further specifications, delivery and price. Note) Please consult with SMC when using. Not available for manual operation. Y: DIN terminal YO: DIN terminal without connector Seal material fluororubber specifications VQ 3M Seal material fluororubber/oil-free specifications VQ 3 M Note) Not available for manual operation. X5(-Q) X3(-Q) B 54

Pilot Operated Port Solenoid Valve for Dry ir VQ0/30 Series Standard Specifications Symbol Construction w (OUT) (IN) N.C. e q VQ0 When the valve is closed, flow is blocked from port to port. However, if the pressure in port is higher than port, the valve will not be able to block the fluid and it will flow from port to port. Valve specifications Electric specifications Series Valve construction Fluid mbient and fluid temperature Lubrication Manual override Impact resistance/vibration resistance Enclosure Internal leakage cm 3 /min Exterior leakage cm 3 /min Mounting orientation Weight Coil rated voltage llowable voltage fluctuation Coil insulation type Power DC voltage (with power-saving circuit) consumption DC voltage (without power-saving circuit) (Current value) C r t y u Electrical entry VQ0 port poppet pilot operated Note ) ir Note ) 0 to 50 C Not required Note 3) Slotted locking type (tool required) 50/30 m/s Note 4) Note 5) Dustproof 5 or less 5 or less Unrestricted 46 g 80 g VDC, 4 VDC, 00 VC, 0 VC, 00 VC, 0 VC ±0% of rated voltage Class B or equivalent Inrush:.9 W, Holding: 0.6 W.9 W V Grommet, DIN terminal Note ) This product is for dry air. Use in clean air, and be sure that drain and oil content does not flow into the product. Note ) Use dry air to prevent condensation when operating at low temperatures. Note 3) Manual override is available only for DIN terminal type. Note 4) Vibration resistance: No malfunction occurred in a one-sweep test between 8.3 and 000 Hz. Test was performed at both energized and de-energized states to the axis and right angle directions of the main valve and armature (value at the initial state). Impact resistance: No malfunction resulted from the impact test using a drop impact tester. The test was performed on the axis and right angle directions of the main valve and armature for both energized and de-energized states (value at the initial state). Note 5) DIN terminal type: pplicable to dusttight and low jetproof (IP65). Characteristic Specifications Series VQ0 Port size ø6 ø8 ø0 ø Note ) Flow rate characteristics C [dm 3 /(s bar)] b Cv.4 0.3 0.33.5 0.4 0.39.8 0.4 0.80 3.0 0.37 0.8 Min. operating pressure differential Note 4) 0.0 MPa Max. operating pressure 0.6 MPa 0.5 MPa Note 3) Note 3) Electricity circuit With power-saving circuit High speed response type With power-saving circuit High speed response type Note ) Response time ON OFF 0 ms or less 5 ms or less 7 ms or less 5 ms or less 5 ms or less 5 ms or less 0 ms or less 5 ms or less Note ) The flow rate characteristics of this product have variations. Note ) JIS B 8373-05 (Value of high response time is subject to change upon pressure, quality of air.) Note 3) It cannot be used when energized continuously. Note 4) If a restrictor (nozzle, etc.) is mounted on the outlet side piping, the pressure differential when ON is smaller. Be sure that the pressure differential does not drop below 0.0 MPa. dditionally, take great care when used for the ejector supply, etc. Component Parts No. 3 4 5 6 7 Description Solenoid coil Body Fixed armature rmature Return spring Poppet Diaphragm assembly Material Resin Stainless steel Stainless steel Stainless steel NBR H NBR, Resin VCH VDW SX0 VQ LVM 55 B

VQ0/30 Series Dimensions: VQ0 Series In-line Type: Grommet (G) VQ-G- - Mounting holes x ø3. through Bracket mounting holes x ø3. through Light Lead wire length pprox. 300 P port C6: One-touch fitting for ø6 C8: One-touch fitting for ø8 C6: One-touch fitting for ø6 C8: One-touch fitting for ø8 Dotted line: Bracket mounting type (-F) 56

Pilot Operated Port Solenoid Valve for Dry ir VQ0/30 Series Dimensions: VQ0 Series Type L: Grommet (G) VQ-G- -L Light Lead wire length pprox. 300 VCH P port C6: One-touch fitting for ø6 C8: One-touch fitting for ø8 VDW SX0 VQ LVM C6: One-touch fitting for ø6 C8: One-touch fitting for ø8 x ø3. mounting hole Dotted line: Bracket mounting type (-LF) 57

VQ0/30 Series Dimensions: VQ0 Series In-line Type: DIN terminal (Y) VQ-Y- - Mounting hole x ø3. through Bracket mounting hole x ø3. through Manual override pplicable cable O.D. ø3.5 to ø7.0 mm P port C6: One-touch fitting for ø6 C8: One-touch fitting for ø8 C6: One-touch fitting for ø6 C8: One-touch fitting for ø8 Dotted line: Bracket mounting type (-F) 58

Pilot Operated Port Solenoid Valve for Dry ir VQ0/30 Series Dimensions: Series In-line Type: Grommet (G) VQ3-G- - Mounting hole x ø4.3 through Bracket mounting hole x ø4.5 through Light Lead wire length pprox. 300 VCH VDW SX0 VQ LVM P port C0: One-touch fitting for ø0 C: One-touch fitting for ø C0: One-touch fitting for ø0 C: One-touch fitting for ø Dotted line: Bracket mounting type (-F) 59

VQ0/30 Series Dimensions: Series DIN terminal (Y) VQ3-Y- - Mounting hole x ø4.3 through Bracket mounting hole x ø4.5 through Manual override pplicable cable O.D. ø3.5 to ø7.0 mm P port C0: One-touch fitting for ø0 C: One-touch fitting for ø C0: One-touch fitting for ø0 C: One-touch fitting for ø Dotted line: Bracket mounting type (-F) 50

Pilot Operated Port Solenoid Valve for Dry ir VQ0/30 Series How to Order Manifold VVQ 08 3 Series VQ0 Stations 0 station 0 0 stations Option D DO P port/thread type 00N 00T 00F CE-compliant Q CE-compliant Rc 3/8 NPT 3/8 NPTF 3/8 G 3/8 None DIN rail mounting DIN rail mounting (Without DIN rail) How to Order Manifold ssembly Enter the mounting valve and option part numbers under the manifold base part number. <Ordering Example> VVQ-05 (-Q) set Manifold part No. VQM-5G-C6 (-Q) 4 sets Valve part No. (Stations to 4) VQM-5G-C8 (-Q) set Valve part No. (Station 5) is the symbol for assembly. dd a in front of the part numbers for solenoid valves, etc., to be mounted. Stations 3 U side D side Enter together in order, counting from station on the D side. [Option] P How to Order Valves (For Manifold) Series/ Orifice diameter Symbol Series VQ0 3 G Y YO Valve Type N.C. (OUT) VQ M G C6 (IN) When the valve is closed, flow is blocked from port to port. However, if the pressure in port is higher than port, the valve will not be able to block the fluid and it will flow from port to port. Valve specifications M Manifold Electrical entry Grommet DIN terminal DIN terminal (without connector) 3 4 5 6 9 Note ) Coil voltage 00 VC (50/60 Hz) 00 VC 0 VC 0 VC (50/60 Hz) 4 VDC VDC Other special voltage Note ) Please consult with SMC for special voltages. Note ) There is polarity for DC voltage (with power-saving circuit type). Electricity circuit Symbol Z H Note) Port size Symbol C6 C8 C0 C DC voltage With power-saving circuit (with surge voltage suppressor protection circuit) With power-saving circuit (with light/surge voltage suppressor protection circuit) High speed response type (without energy-saving, light/surge voltage suppressor circuit) Made to Order specifications Q (Refer to the table below) Port size One-touch fitting for ø6 One-touch fitting for ø8 One-touch fitting for ø0 One-touch fitting for ø VQ0 Manual override None B Note) Slotted locking type (tool required) Note) Only normally closed DIN terminal in-line type is applicable. Note) H is available only for DC voltage and cannot be energized continuously. CE-compliant CE-compliant C voltage With full wave rectifier circuit (with surge voltage suppressor protection circuit) With full wave rectifier circuit (with light/surge voltage suppressor protection circuit) VCH VDW SX0 VQ LVM Made to Order Specifications Please contact SMC for further specifications, delivery and price. Oil-free specifications VQ 3 M X (-Q) Note) Please consult with SMC when using. Not available for manual operation. Seal material fluororubber specifications VQ 3 M X5 (-Q) 5 B

VQ0/30 Series Dimensions Plug lead unit manifold (VVQ- ) Mounting hole x ø4.5 through L4 L3 L 5 35 L C6: One-touch fitting for ø6 C8: One-touch fitting for ø8 P = 9 4.5 47 35 x Rc 3/8 P port 4 8 73 P DIN rail mounting 4 x M3 x 0.5 7.5 6.6 66 9.8 5. 4 L5 5.6 Dotted line: DIN rail mounting (-D) Dimensions L L L L3 L4 L5 n 3 4 5 6 7 8 9 0 78 68 07 97 36 6 65 55 94 84 3 3 5 4 8 7 30 300 00 37.5 6.5 87.5.5 50 75 300 337.5 0.5 48 73 98 3 60.5 85.5 30.5 348 66.8 95.8 4.8 53.8 8.8.8 40.8 69.8 98.8 49 39 75 85.5 37.8 Formulas L = (n ) x 9 + 49 L = L 0 L3 = L4 0.5 L5 = L. n: Station (Max. 0) 3 4 5 6 7 8 9 0 339 368 397 46 455 484 53 54 57 600 39 358 387 46 445 474 503 53 56 590 36.5 387.5 45 450 475 500 537.5 56.5 587.5 65 373 398 435.5 460.5 485.5 50.5 548 573 598 635.5 37.8 356.8 385.8 44.8 443.8 47.8 50.8 530.8 559.8 588.8 5

Pilot Operated Port Solenoid Valve for Dry ir VQ0/30 Series Dimensions Plug lead unit manifold (VVQ3- ) Mounting hole x ø4.5 through L4 L3 L 5 35 L C0: One-touch fitting for ø0 C: One-touch fitting for ø P = 37 8 59 4 x Rc 3/8 P port 78.7 8 4 DIN rail mounting 4 x M3 x 0.5 5. 7.5 6.6 66 9.8 4 VCH P VDW SX0 VQ LVM L5 5.6 Dotted line: DIN rail mounting (-D) Formulas L = (n ) x 37 + 56 L = L 0 L3 = L4 0.5 L5 = L. Dimensions n: Station (Max. 0) L n 3 4 5 6 7 8 9 0 3 4 5 6 7 8 9 0 L L 56 46 93 83 30 0 67 57 04 94 4 3 78 68 35 305 35 34 389 379 46 46 463 453 500 490 537 57 574 564 6 60 648 638 685 675 7 7 759 749 L3 75.5 50 87.5 5 6.5 300 337.5 375 4.5 450 487.5 55 56.5 587.5 65 66.5 700 737.5 775 L4 85.5 3 60.5 98 35.5 73 30.5 348 385.5 43 460.5 498 535.5 573 598 635.5 673 70.5 748 785.5 L5 44.8 8.8 8.8 55.8 9.8 9.8 66.8 303.8 340.8 377.8 44.8 45.8 488.8 55.8 56.8 599.8 636.8 673.8 70.8 747.8 53

VQ0/30 Series Single Unit Option Bracket assembly (with mounting screws) For fixing this solenoid valve. Type VQ0 Grommet in-line type VQ0 Grommet L type, DIN terminal type DIN terminal L type Bracket assembly XT835-3 XT835-3- XT835-3-3 XT837-3 (Mounting screws, pcs.) M3 x 45 M3 x 40 M3 x 35 M4 x 45 Manifold Option DIN rail XT00-DR- L.5 (Pitch) 5.5 7.5 Suffix the number from DIN rail dimensions table below. Refer to the dimension drawing for each manifold for L dimension. 5.5 35 5 Each manifold can be mounted on a DIN rail. Order with the option symbol -D to specify DIN rail mounting type. The DIN rail is approximately 30 mm longer than the length of manifold. L dimension VQ0 series Stations No. L.5 3 4 5 6 7 8 9 0 3 4 5 6 7 8 9 0 6 8 3 5 7 0 4 7 9 3 34 36 38 40 43 45 47 50 85.5 0.5 48 73 98 3 60.5 85.5 30.5 348 373 398 435.5 460.5 485.5 50.5 548 573 598 635.5 series Stations No. 6 9 3 4 5 5 8 6 7 4 8 7 9 30 0 33 36 39 3 4 4 45 5 47 6 50 7 53 8 56 9 59 0 6 L 85.5 3 60.5 98 35.5 73 30.5 348 385.5 43 460.5 498 535.5 573 598 635.5 673 70.5 748 785.5 DIN rail mounting bracket VVQZ00-DB-5 This bracket is used for mounting the manifold on the DIN rail. DIN rail mounting bracket is attached on the manifold. set of DIN rail mounting brackets for manifold includes brackets. Blanking plate assembly (with O-ring and mounting screws) Mount a blank plate on valve manifold when a valve is disassembled for maintenance purposes, or when spare valve unit is supposed to be mounted in the future. Series VQ0 Blanking plate assembly XT835-35 XT837-35 (O-ring) OR-679-00-H OR-400-50-H (Mounting screws, pcs.) M3 x 6 M4 x 6 54

VQ0/30 Series Specific Product Precautions Be sure to read this before handling the products. Refer to back page 50 for Safety Instructions and pages 7 to 9 for Port Solenoid Valve for Fluid Control Precautions. Warning Selection. ir quality This product is for dry air. Drain, oil, etc. in the air may result in faulty operation. Use clean (dry) air.. Pressure differential If a restrictor (nozzle, etc.) is mounted on the outlet side, the outlet side pressure differential at the inlet side is smaller. Be sure the pressure differential when ON does not drop below 0.0 MPa. Manual Override Warning Regardless of electric signals to the solenoid valve, the manual override is used for switching the main valve. (DIN terminal only.) Push the manual override Slotted locking type (tool required) button with a small flat head screwdriver until it stops. Turn it in the counterclockwise direction at ø3.8 90 to lock the manual. Turn it right to release. LED PUSH Timer circuit TURN LOCK Connection and Electrical Circuit Caution Black ( ) DC Blue (00 VC) Red (00 VC) Gray (Other C) Red (+) DC Blue (00 VC) Red (00 VC) Gray (Other C) Grommet lead wire WG, Insulator O.D..6 mm With DC voltage power-saving circuit (with polarity) Lead wire color DIN connector Red (+) SOL. Connection and Electrical Circuit Caution Power wave form of power-saving type (Rated voltage at 4 VDC) pplied voltage 4 V C circuit Lead wire color Blue (00 VC) Red (00 VC) Gray (Other C) Blue (00 VC) Red (00 VC) Gray (Other C) 0 V 0 to 0 ms.9 W 0.6 W 0 W DIN connector Caution Power-saving Valve Mounting When mounting the valve, secure with brackets. When mounting it directly, tighten the mounting screws with the appropriate torque (0.7 to 0.8 N m). Mounting screw Tightening torque 0.7 to 0.8 N m LED When Energizing Continuously for Long Period of Time SOL. Caution When energizing continuously, choose the option of an energysaving circuit specifications. High speed response type (with no energy-saving circuit) cannot be energized continuously. VCH VDW SX0 VQ LVM Black ( ) i i i: Inrush current, i: Holding current DC (with power-saving circuit) specifications is designed to reduce the power consumption at holding to achieve powersaving by circuit shown above. Refer to below power wave form. 55

VQ0/30 Series Specific Product Precautions Be sure to read this before handling the products. Refer to back page 50 for Safety Instructions and pages 7 to 9 for Port Solenoid Valve for Fluid Control Precautions. How to Wire DIN Terminal Caution ISO#: Based on DIN 43650C (Pin gap 8 mm) Connection. Loosen the tightening screw and pull the connector off of the solenoid valve.. fter removing the tightening screw, divide the terminal block and housing by prying open the slot area of the lower part of the terminal block open with a screwdriver. 3. Loosen the terminal screws of the block and insert stripped lead wires in accordance with the wiring diagram. Secure each wire by re-tightening the terminal screw (In the case of terminal : (+), : (-) DC) 4. Tighten the ground nut to secure the cable wire. Change of electrical entry Wire entry can be changed by mounting the housing in either direction (four directions at every 90 ) after dividing the terminal block and the housing. For the indicator lighted type, be careful not to damage the light with the lead wire of the cable. Precautions Insert a connector straight or pull it out straight, using caution it does not be tilted. pplicable cable Cord O.D.: ø3.5 to ø7 (Reference) 0.5 mm -core and 3-core wire equivalent to JIS C 3306. Ground nut Tightening torque.65 to.5 N m Washer Grommet (Rubber) (Voltage symbol) Refer to the following table Tightening torque 0. to 0.5 N m Terminal screw (3 positions) Tightening screw Tightening torque 0.3 to 0.4 N m Housing (Position for light mounting) Terminal block Shaved part DIN Terminal Part No. (Based on DIN) Without indicator light SY00-8-4 With Indicator Light Rated voltage Voltage symbol Part no. 4 VDC VDC 00 VC 00 VC 0 VC 0 VC 4 V V 00 V 00 V 0 V 0 V SY00-8-3-05 SY00-8-3-06 SY00-8--0 SY00-8--0 SY00-8--03 SY00-8--04 DIN Terminal Circuit with Indicator Light C circuit How to Wire DIN Terminal NL R NL: Neon light R: Resistor Manifold How to Mount/Remove from DIN Rail Caution Removing procedure. Loosen the clamp screw on the side of both ends of the manifold.. Lift the side of the manifold off the DIN rail and slide it in the direction of the arrow. Mounting procedure. Hook the mounting hook on the B side of the manifold base to the DIN rail.. Press down side and mount the end plate on the DIN rail. Tighten the clamp screw on side B of the end plate. (Tightening torque: 0.3 to 0.4 N m). Caution Valve Mounting DC circuit LED R LED: Light emitting diode R: Resistor fter confirming the gasket is correctly placed under the valve, tighten the mounting screws with the appropriate torque (0.7 to 0.8 N m). Manifold mounting screw B Manifold mounting screw 56