Solar PCU RATING 100VA 500VA 600VA 600VA/1KVA 2KVA 3KVA 4KVA 5KVA 6KVA 10KVA 10KVA PV CHARGE CONTROLLER RATING 100Wp 500Wp 600Wp 600Wp/1kWp 2kWp 3kWp 4kWp 5kWp 6kWp 10kWp 10kWp Model No. PCU1H24 PCU5H24 PCU600H24 PCU 6H24/1K24 PCU2K48 PCU3K48 PCU3K96 PCU4K96 PCU5K96 PCU6K96 PCU10K120 PCU10K180 Type Technology Power device Single Phase Solar Power Conditioning Unit DSP Based PWM Technology IGBTs cum MOSFETs PCU INPUT PARAMETERS Nominal I/P DC Voltage 24V 24V 48V 96V 120V 180V Input DC Voltage Range 23.2-28.8V±0.2V 23.7-28.8V±0.2V 22V-30V±0.4V 44V-60V ±2% 88V-120V ±2% 110V-150V±2% 165V-225V±2% Low Battery cut off 23.2V±0.2V 23.7v±0.2V 22.6V ± 0.4V 44V ±2% 88V±2% 110V±2% 165V±2% Inverter Restart time after low battery Battery voltage should be Battery voltage should be 25.5V when mains is not available Battery voltage should be 27V 51V Battery voltage should be 103V Battery voltage should be 129V Battery voltage should be 194V High Battery shutdown 31V±2V NA 65V ±2% 130V ±2% 162±2% 244±2% No load Power Consumption with No load shutdown enable Less than 10W Less than 10 W Less than 15W Less than 20W Less than 30W Less than 30W No load shutdown ON/OFF (Factory settable as per customer requirement) OUTPUT PARAMETERS Waveform & Regulation Frequency Regulation If the load is <60W,Output 5sec. ON and 50sec OFF every cycle. GRID CHARGER Grid I/P Voltage Range 150VAC-260VAC±10V 160VAC-250VAC±10V WW-175-285&NW-190-265±10V Charging Current 4.0A±0.5A 13.0A±1A 20.0A±1A 13A±1A SOLAR CHARGE CONTROLLER Type Maximum I/P PV Voltage Solar Array MPPT Charging Current Imax. Peak 5.0A 24.0A 20.0A 20A / 40A > 30A > 45A > 22A > 30A > 45A > 45A > 60A > 40A Bulk Voltage 28.4V +Temp. Compensation 28.8V±0.4V 57.6V ±2% 115.2V ±2% 145±2% 216±2% Adjustable Bulk Voltage (Adjustable 27.6V-28.8V) factory setting 28.8V 26.5V-30V 53V-60V 106-120V 132.5V-150V 199V-225V Transition from float to bulk N/A Below float level for a cumulative period of 1 hour Float Voltage 27.4V+Temp. Compensation 27V±0.4V 54V ±2% 108V ±2% 135±2% 202±2% PROTECTION Over Current, Battery over Charge Protection, PV/Battery Reverse Polarity, Reverse Current Flow, High Temperature Automatic Charger Restart Time after High Current Cooling 3.5 Minutes Forced air DATA LOGGING AND MONITORING Parameters Solar Energy Generated PC Datalogging OTHER SPECIFICATIONS Visual messages (LCD) DIELECTRIC STRENGTH IEC standard Design service use Operating Temp. Storage Temp. Acoustic Noise @ 1metre N/A Pure Sine Wave 220V±2% Internal data log for 7 days for following parameters @ 1hour interval scanning : Date; time ; PV voltage ;PV current ; PV Power ; output Cumulative Solar Energy kwh measurement Solar Cumulative KWH, PV Voltage, PV current, Battery Voltage, Output Voltage, Load %, Overload, Charging Current, Battery Low/High, Short circuit, Array Reverse Polarity (through LED) etc. IEC61683, IEC60068-2-1,2,14,30,31 ; IEC62093 NA NA PV Voltage, PV current, Battery Voltage, Output Voltage, Load %, Overload, Charging Current, Battery Low/High, Short circuit IEC61683, IEC60068-2-1,2,14,30,31 (N/A for 6H24) ; IEC62093 Technical Specifications of Solar PCUs IEC61683, IEC60068-2- 1,2,14,30,31 ; IEC62093 50Hz + 0.2Hz 25V Per 36cell Solar module Single Array N/A Indoor N/A IEC61683, IEC60068-2- 1,2,14,30,31 ; IEC62093 Permanent OFF after 5minutes if load is 40W WW-155 VAC-280VAC±10V and NW-185 VAC-265VAC±10V Max. 30Amp + 2Amp ( Factory settable) Series Regulator Common Negative Internal data log for 7 days for following parameters @ 1hour interval scanning : Date; time ; PV voltage ;PV current ; PV Power ; output voltage AC; Output current AC; O/P cum. kwh. Cumulative Solar Energy kwh measurement PC GUI based data monitoring and storage. Solar Cumulative KWH, PV Voltage, PV current, Battery Voltage, Output Voltage, Load %, Overload, Charging Current, Battery Low/High, Short circuit, Array Reverse Polarity (through LED) etc. 2KV input/output with ground and 1.5KV between input & output after removal all grounds and control cards. 0 C to + 55 C 0 C to + 55 C < 60dB Pure Sine Wave, 230V + 5% Efficiency (typical)at linear load 88% 85% 82% 85% 82% 85% Total Load 100W @ UPF / 500W @ UPF 600W@UPF 600VA@.8PF/1kVA @.8PF 2kW@UPF 3kW@UPF 4kW@UPF 5kW@UPF 6kW@UPF 10kW@UPF 10kW@UPF Overload THD (Linear load) Crest Factor Power usage Priority 200% for 8seconds 5% on linear load 3:1 From Photovoltaic Array Automatic only after low battery cut-off and after attaining float charge stage mains power usage will discontinue and charging from mains will happen during 10 am to 6 pm only when PV power is Grid power connects to the load when battery voltage 24/48/96/120/180 V ± 2% in SMB (Solar-Mains Battery) and 23.4/45/90/112/168 V± 2% in SBM (Solar-Battery-Mains) mode. Grid power usage Transfer Time inverter to mains and viceversa insufficient. Typical>20msec. Typical 15 msec. N/A N/A N/A N/A
Relative Humidity 0-95% Non-Condensing Size (WxDxH) ± 10mm 245x430x155 247X423X269 xxx 245x450x356 351x617x320 350x585x665 Weight (approx. in Kg) ± 400gm 9.13Kg 17.5Kg. xxx 17.6/23.6 35 61 68.7 72 86 106 110 Note: Specifications are subject to change without any prior notice. As on september 2013