Solenoid interlocks AZM 170 range. 98 Schmersal 22 8,2 60. ø4,2. ø Pg 11

Similar documents
Solenoid interlocks AZM 161 range Schmersal. a 5,5. Pg11/M16x1,5

Solenoid interlocks AZM 190 range. 128 Schmersal ,3 4,5 M20 17,5 23,5

Solenoid interlocks AZM 415 range. 134 Schmersal 29,5 6,5 24,7. 8,6 Pg 13,5 46,5 24,5

Technical data. Standards: IEC/EN ; EN ISO ; EN 1088; BG-GS-ET-19

Safety door-handle system STS

AZM 161SK 12/12RKED/TU 024

Ordering details. Approval. Classification. Global Properties :18:33h. Solenoid interlock / AZM 161

Technical data. Standards: IEC/EN BG-GS-ET-15

SERIES AZM170. Solenoid-Latching Machine Guard Safety Interlock Switch. Features & Benefits. Description. Typical Applications

Operating instructions Solenoid interlock EX-AZM About this document. Content

Operating instructions Solenoid interlock AZM 161../.. 1. About this document. Content

Datasheet - AZ ZUEK Safety switch with separate actuator / AZ 3350

Safety Switches with Separate Actuator SKC

Operating instructions Solenoid interlock AZM 161../.. 1. About this document. Content

Solenoid interlock AZM 200 The non-contact interlock.

Operating instructions Solenoid interlock AZM /.. 1. About this document. Content

Safety switches / Position switches / Command devices

Technical data. Standards: IEC/EN EN 574 EN 418. powder-coated Protection class: IP 65. Cable section: max. 1.5 mm V I the :

Operating instructions Solenoid interlock TKM/TKF. 1. About this document. Content

Command devices Pull-wire emergency stop switches One-side operation ZS 71 range Schmersal Industrial Switchgear.

Safety switches with separate actuator

Guard locking systems for the protection of man and machine

Technical data. Standards: IEC/EN , EN ISO , IEC 61508, IEC

Safety switches with solenoid and separate actuator

Recommended use With its standard enclosure, the ENM2 limit switch can be used universally in all industrial and safety applications.

Safety switches with solenoid and separate actuator

Installation and Operating Instructions

Installation and Operating Instructions

Datasheet - TV8S /20Z Safety switch for hinged guards / Hinge safety switch / TV8S 521

Safety switches with separate actuator

Safety switches for hinged doors

Door locking devices. 4 Schmersal Industrial Switchgear

Operating instructions Trapped key system SHGV / SVE / SVM. 1. About this document. Content

FL series position switches

Position switches FD series

SERIES Z/T236. Safety-Rated, Positive-Break Miniature DIN Limit Switches. Features & Benefits. Description. Typical Applications ORDERING GUIDE

Position switches FR series

LR-LX-LK-LW Safety Switches with separate actuator

Safety switches for hinges

Operating instructions Solenoid interlock AZM 170

Operating instructions Safety sensor BNS About this document. Content. 6 Disassembly and disposal 6.1 Disassembly Disposal...

Switches with manual reset

Floor and fine adjustment switches

Prewired position switches FF series

Safety rope switches with reset for emergency stop

D4DL. Guard Lock Safety-door Switch. Ordering Information. Model Number Legend Switches D4DL- -

Safety rope switch without reset for simple stop

Position switches FC series

Approbationen IEC/EN ; UL 508; CSA-C22.2 No ; CE marking

Control Equipment. ATHEX bvba Tel: +32 (0) Fax: +32 (0) Alpenroosbaan 2, 2900 Schoten, België

Position switches FR series

Operating instructions Solenoid interlock AZM About this document. Content

Position Switches Series 8074/2

LK Position Switches TECHNICAL DATASHEET.

Safety rope switch with reset for emergency stop

Safety Sensor CSS 180 Product Information

Solenoid Locking Safety Switches

General_technical_data Series

TAE pole Contactors

Solenoid Locking Safety Switches

3SE3 1 SIGUARD Position Switches

Technical Information

Prewired position switches FF series

W Datasheet: DIN Rail Contactors, series AMPARO

Technical data. Rated operating current/voltage I e /U e : AC-15: 2 A / 24 VAC DC-13: 1 A / 24 VDC Thermal test current I the : 2.

Standard Interlock Safety Switches

Application Mini Contactors for Motors and Resistive Loads

CI-TI Contactors and motor starters Types CI 61 - CI 98

Instructions Contact numbers to EN Coil terminal markings to EN Integrated diode-resistor combination Coil rating 2.

Safety switches for hinged doors

Datasheet - MV8H Y

D4DL. Ordering Information. Compact Guard-locking Interlock Safety Door Switch. Model Number Legend Switches D4DL- -

Position Switches Series 8060/2

Online data sheet. i15-em0123 Lock i15 Lock SAFETY LOCKING DEVICES

Technical data. Standards: IEC/EN thermoplastic tightening force on nut 22 mm A/F max. 300 Ncm Protection class: IP 67 to EN 60529

Standard Interlock Safety Switches

Single foot switches - PX and PA series

AZM300 More than just a solenoid interlock

DATASHEET - DILMC9-10(24VDC) Technical data General. Contactor, 3p+1N/O, 4kW/400V/AC3. Catalog No Eaton Catalog No. XTCEC009B10TD.

General_technical_data Series

Encontrará el manual de instrucciones actual en su idioma oficial de la UE en nuestra página de Internet www. schmersal.net.

HS1C Interlock Switches with Solenoid

Position Switches Series 8070/2

SFS-UFS Single Foot Switches

General_technical_data Series

S826, S926 Series Dual changeover switches with positive opening operation and wiping contacts Catalogue D26.en

For Info: Phone: Fax:

RSC09 RSC16 RSC22 RSC38 RSC43 RSC63 RSC-AUX

Instructions Contact numbers to EN Coil terminal markings to EN Integrated diode-resistor combination Coil rating 2.

HS1E Series Full Size Interlock Switch with Locking Solenoid

HS1C Series Full Size Interlock Switch with Locking Solenoid. GS-ET-15 BG standard in Germany. HS1C Series Functionality

Operating instructions Pull-wire emergency-stop switches EX-ZQ About this document. Content

Operating instructions Switching cushion with safety function SSG-SK. 1. About this document. Content

3 - Protection components Motor circuit-breakers

BETA Switching Switches and Light Indicators

HS5E Miniature Interlock Switches with Solenoid

B115...B180 RF200 RFN200 B250...B400 RF400 RFN400

HS1E Series Full Size Solenoid Locking Switches

CI-TI Contactors and Motor Starters Type CI 6-50

Miniaturized limit switches

Transcription:

2.4 AZM 170 range Features Thermoplastic enclosure Compact design Manual release Long life Double insulated X High holding force 1,000 N N latching force Cut clamp termination Actuation on de-energisation or energisation Voltage variants 24 VAC/DC 0 VAC 2 VAC Always state required supply voltage when ordering Included in delivery Cable entry Pg Slot sealing plug 24 4 90 1 ø4,2,2 60 15 24 5 Pg ø4-10 Manual release Manual release from side Approvals For manual release using M5 triangular key, available as accessory Included in standard version H Z C D D S USA CAN Additional release facility on side, ordering suffix -2197 Only available on versions actuated on de-energisation 9 Schmersal

2.4 AZM 170 range Cut clamp This type of termination (IDC method) enables simple connection of flexible conductors without the need for the use of conductor ferrules. 70 mm Info Further variants not shown here are available on enquiry. The applicable ordering suffix is added at the end of the part number of the solenoid interlock. With gold-plated contacts (0. µm), ordering suffix -167 Available with 5 N latching force, part number without r, e.g. AZM 170-zk Actuation on de-energisation 1 NO 1 NC 2 NC Contacts/ Switch travel 0 4,2 7,6-14 -2 0-12 -2 With manual release With side release AZM 170-zrk AZM 170-zrk-2197 AZM 170-02zrk AZM 170-02zrk-2197 Actuation on energisation 1 NO 1 NC 2 NC Contacts/ Switch travel 0 4,2 7,6-14 -2 0-12 -2 With manual release AZM 170-zrka AZM 170-02zrka Notes Schmersal The contact 21-2 is solenoid locking principle or de-energisation of the coil A1-A2. Circuit diagrams show de-energised condition with actuator inserted (0 in switch travel diagram). Interlocks with actuation on energisation may only be used in special cases after a thorough evaluation of the accident risk, since the guarding device can immediately be opened on failure of the electrical power supply or when the main switch is opened. Actuators must be ordered separately. A selection of suitable actuators can be found in 2.10. 99

2.9 Wiring diagrams AZM 170-F 05 with fail-safe standstill monitor Application AZM 170-F 05 solenoid interlock with integral fail-safe standstill monitor to protect a guard system and monitor standstill of a motor using two inductive proximity switches Protection up to Control Category to EN 954-1 in combination with a guard door monitor, see 10.2 Use of inductive DC proximity switches with pnp output, see Schmersal Catalogue Part 2 Wiring diagram L1 +24V S A1 A2 Y1 X1 AZM 170-yrk-F05/AZM 170 -yri-f05 max. 100mA AES 15 K1 K2 S S14 S21 S 14 24 14 21 2 A1 A2 X1 X2 X X4 X5 X6 X7 H1 +24 VDC R E N SK M +24VDC 10 Schmersal

2.9 Wiring diagrams AZM 170-Z 05 with fail-safe delay timer Application AZM 170-F 05 solenoid interlock with integral fail-safe delay timer to protect a guard system and enable the solenoid interlock when a preset time has elapsed Protection up to Control Category to EN 954-1 in combination with a guard door monitor, see 10.2 The set time is started by an anticoincidence signal, e.g. from motor contactor Wiring diagram L1 0 +24V S A1 A2 max. 100mA Y1 X1 AZM 170-yrk-Z05/AZM 170-yri-Z05 max. 100mA AES 15 K1 K2 S S14 S21 S 14 24 14 21 2 A1 A2 X1 X2 X X4 X5 Y1 Y2 +24 VDC +24 VDC E H1 N M Schmersal 109

2.10 Actuators Straight actuator AZ 17/170-B1 Particularly suitable for sliding doors On hinged guards, minimum actuating radius at 90 to the plane of the actuator 140 mm, minimum actuating radius in line with the plane of the actuator 200 mm 4,5 10 20 4, 10 Rmin.140 10 Rmin. 200 2 The axis of the hinge should be 10 mm above the top edge of the solenoid interlock and in the same plane Angled actuator AZ 17/170-B5 Particularly suitable for hinged guards (front mounting) On hinged guards, minimum actuating radius at 90 to the plane of the actuator 140 mm, minimum actuating radius in line with the plane of the actuator 200 mm 7,5 20 4, 12 6 Rmin.140 Rmin. 200 2 The axis of the hinge should be mm above the top edge of the solenoid interlock and in the same plane Adjustable actuator AZM 170-B6 For very small actuating radii at 90 to or in line with the plane of the actuator Actuating radius adjustable, minimum 50 mm, using an hexagonal key wrench 2 mm A/F (a and b) The direction of actuation can be selected by applicable insertion of the insert Rmin.50 Rmin.50 2 12 a 20 7 24 4 b The axis of the hinge should be mm above the top edge of the solenoid interlock and in the same plane a 2 b 2 0 Schmersal

2.10 Actuators Long straight actuator AZ 17/170-B Particularly suitable for sliding doors On hinged guards, minimum actuating radius at 90 to the plane of the actuator 140 mm, minimum actuating radius in line with the plane of the actuator 200 mm 20 4, 7,5 Rmin.140 7,5 Rmin. 200 60,5 7,5 The axis of the hinge should be 7.5 mm above the top edge of the solenoid interlock and in the same plane 2 Long angled actuator AZ 17/170-B15 Particularly suitable for hinged guards (front mounting) On hinged guards, minimum actuating radius at 90 to the plane of the actuator 140 mm, minimum actuating radius in line with the plane of the actuator 200 mm 25 Rmin.140 25 Rmin. 200 4 12 4, 25 16 2 The axis of the hinge should be 25 mm above the top edge of the solenoid interlock and in the same plane 20 Straight actuator with rubber mountings AZ 17/170-B1-45 Particularly suitable for sliding doors On hinged guards, minimum actuating radius at 90 to the plane of the actuator 140 mm, minimum actuating radius in line with the plane of the actuator 200 mm Damps vibration on guards 1 ø ø4,2 Rmin.140 Rmin. 200 The axis of the hinge should be mm above the top edge of the solenoid interlock and in the same plane Tightening torque of actuator max. 200 Ncm 6 Schmersal 1

2. Accessories Connector plug M 12 x 1 for AZM 170-ST with connector ca. 54 ø14,5 ø19,6 Straight connector plug A-coding: Part number Series 7 B-coding: Part number Series 715 Connector plug M 12 x 1 for AZ 170-ST with connector 41,5 Straight connector plug with pre-wired cable Cable 5 m long Conductors: 4 x 0.75 mm 2 A-coding: Part number Series 76 B-coding: Part number Series 766 Tamperproof screws Screw lengths Pan-head screws with unidirectional slots M 4 x, Id. No.: 504 9 6001 Supplied in sets of 2 screws To mount the actuator Higher protection against tampering with interlock Protect against unauthorised removal of actuator 2 Schmersal

2. Accessories Mounting set MS AZM 170 For simple mounting on profile systems Mounting of the solenoid interlock parallel or right-angled to the safety guard Mounting plate AZ 17/AZM 170 45 21 Hinweis The mounting sets can only be used in conjunction with actuator AZM 170-B6. Solenoid interlock and actuator are not included in delivery. 24 16 6,2 Legend MS AZM 170 P Mounting parallel to safety guard 1 Roundhead screw M4 x per ISO 7 2 Washer per DIN 4-4, Roundhead screw M4 x 10 per ISO 7 4 Mounting plate AZ 17/AZM 170 5 U-profile AZM 170 6 Mounting angle AZM 170 Not provided: 7 Solenoid Interlock AZM 170 Actuator AZM 170-B6 U-profile AZM 170, 12 6,2 9 60 140 90 2 41 5 1 4xM4 7 2 7 29 4 60 4 5 2 Mounting angle AZM 170 2x4,2 64 15 7 90 2xM4 1 MS AZM 170 R/P Mounting right-angled to safety guard 7 1 4 5 2 1 7 6 2 Schmersal

2.27 Technical data AZM 161 AZM 170 AZM 170-ST AZM 170i AZM 170i-ST AZM 170 SK Standards: IEC/EN 60947-5-1/DIN VDE0660-200; EN 10; BG-GS-ET-19 Enclosure material: Glass-fibre reinforced thermoplastic, self-extinguishing Actuator and latching bolt: Stainless steel 1.41 Protection class: IP 67 to IEC/EN 60529/DIN VDE 0470-1 Contact material: Silver Contact type: Changeover with double break Zb, or 2 NC Changeover with double break Zb, or NC or 4 NC contacts, with galvanically with galvanically separated contact separated contact bridges bridges Switching system: A IEC 60947-5-1; B BG-GS-ET-19; slow action, NC contacts with positive break Termination: Screw terminals or Cut clamp terminals Connector M 12 x 1, cage clamps (IDC method) four pole max. 1.5 mm 2 0.75 1.0 mm 2 flexible (incl. conductor ferrules) Ordering suffix SK: Screw terminals 1.5 mm 2 flexible Rated impulse withstand voltage U imp : 4 kv Rated insulation voltage U i : 250 V Thermal test current rating I th : 10 A Utilisation category: AC-15; DC- AC-15 Rated operating current/voltage I e /U e : 2.5 A/24 VDC; 4 A/2 V 4 A/2 VAC Max. fuse rating: 6 A gl/gg D-fuse Positive break travel:. mm mm Positive break force: 10 N for each NC 6 N for each NC contact fitted contact fitted (depending on the setting of the ball latch) Solenoid duty rating: Continuous operation Rated control voltage U S : 24 VAC/DC 24 VAC/D or 0 VAC/DC, 50/60 Hz or 0 VAC/DC, 50/60 Hz or 2 VAC/DC, 50/60 Hz or 2 VAC/DC, 50/60 Hz Consumption: Max. 10 W Ambient temperature: 25 C + 60 C Mechanical life: > 1 million operations Holding force F max. : 2,000 N 1,000 N Holding force of integral ball latch: Latching force: N for Ordering Suffix r 152 Schmersal

2.27 Technical data AZM 170-F05 AZM 170-Z05 AZM 190 AZM 170i-F05 AZM 170i-Z05 Standards: IEC/EN 60947-5-1/DIN VDE0660-200; EN 10; BG-GS-ET-19 Enclosure material: Glass-fibre reinforced thermoplastic, self-extinguishing Glass-fibre reinforced thermoplastic Actuator and latching bolt: Stainless steel 1.41 Zinc-plated metal / aluminium Protection class: IP 65 IP 67 to IEC/EN 60529/DIN VDE 0470-1 Contact material: Silver Contact type: Changeover with double break Zb, Changeover with with galvanically separated contact bridges double break Zb with galvanically isolated moving contacts Switching system: A IEC 60947-5-1; B BG-GS-ET-19; slow action, NC contacts with positive break Termination: Removable terminal block with cage clamps Screw terminals for max. 2.5 mm 2 max. 1.5 mm 2 cables (including conductor ferrules) Rated impulse withstand voltage U imp : 4 kv 2.5 kv Rated insulation voltage U i : 250 V 400 V Thermal test current I th : 10 A Utilisation category: AC-15 AC-15; DC- Rated operating current/voltage I e /U e : 4 A/2 V A/2 V, 5 A/24 VDC Max. fuse rating: 6 A gl/gg D-fuse 10 A gl/gg D-fuse Positive break travel: mm 2 x.5 mm Positive break force: 6 N for each NC 20 N contact fitted Solenoid duty rating: Continuous operation Rated control voltage U S : 24 VAC/DC 24 VDC; 4 VAC; or 0 VAC/DC, 50/60 Hz 0 VAC; 2 VAC or 2 VAC/DC, 50/60 Hz Consumption: Max. 10 W Max..5 W Ambient temperature: 0 C + 55 C 0 C + 50 C Mechanical life: > 1 million operations 2 million operations Holding force F max. : 1,000 N 1,500 N Holding force of integral ball latch: Latching force: N Schmersal 15