PASSPORT Cylindrical Lock. Installation Instructions A8033G 04/16

Similar documents
PASSPORT Cylindrical Lock Installation Instructions A8013H 04/16

PASSPORT Mortise Lock. Installation Instructions A8032G 04/16

TCPWI1/TCPIP1. Attention Installer

IN100. with Aperio Technology. Cylindrical Lock Installation Instructions A8189B 07/16

IN120 WiFi. Installation Instructions ED5200(S)N Series Exit Devices (Includes: Rim and SecureBolt ) Attention Installer FM432 04/16

(SB2) (SB1) (SB3) (SB5) (SB4) Cylindrical Installation Instructions. A. CHECKLIST (4 each AA Batteries Included) (SB1) (SB4) (SB2) (SB6) (SB6) (SB3)

IN100. with Aperio Technology. Mortise Lock Installation Instructions A8190B 07/16

Cylindrical Lockset Installation Instructions CL33600 TCRNE1 Series M812 - iclass Reader Option

IN100. with Aperio Technology. Mortise Lock Installation Instructions

Installation Instructions RF4510-EA

Mortise Lockset IN100 with Aperio Technology Installation Instructions

Mortise Lockset Installation Instructions ML20600 TCRNE1 Series M812 - iclass Reader Option

ASSA ABLOY. Access 600 Integrated Wiegand. with MELR Option (Electric Latch Retraction) Access 600 Integrated Wiegand ASSA ABLOY.

Installation Guide(s)

Installation Instructions For Profile Series v.g1.5 Cylindrical Lock

ELR Series Multi-Point Lock Installation Instructions

ASSA ABLOY. Installation Instructions. MP9800 Series Multi-Point Lock with MELR Option (Electric Latch Retraction)

Certification Exhibit FCC ID: SK9OW1 IC: 864G-OW1. FCC Rule Part: IC Radio Standards Specification: RSS-247. ACS Project Number:

QIS Hardwired Roller Shade User Manual

v.g1.5 Profile & LK Mortise Lock Installation Instructions A7855D 04/18

CHARGING FOLIO. for iphone 6 USER GUIDE

Installation Instructions for CL33800 TCAC2 Series Cylindrical Lockset

Access 800. Installation Instructions for CL33800 TCAC2 Series Cylindrical Lockset

Automated Coupled Roller Shade Instruction Manual. link. Coupled Shade System 2.6 and 3.3 Bracket Standard Roll Inside or Outside Mount

Yale Real Living Push Button Lever Installation and Programming Instructions

HOMELINK DOOR OPENER KIT

Owner s Manual Embedded Solutions. Low Profile (Model Number: LPIC-L0001) Puck (Model Number: LPIC-P0001) Standard Profile (Model Number: LPIC-S0001)

CM5100 COMPUTER MANAGED CYLINDRICAL LOCK HARD-WIRED (FSE/FSA) INSTALLATION MANUAL

Installer Guide smart connect

Tractor Interface Module Installation Instructions. Switch Input (TIM-SI)

P

XM Series. Quick Start Guide. Technology at Work XMCom9


Please keep this instruction sheet for future reference, as it contains important information. Requires three AA batteries for operation (included).

X0056. fisher-price.com

HP10325 KIT. AMP Wireless Air Controls

Press the buttons for fun sounds and music! fisher-price.com

Y9854. fisher-price.com

V9961 V9961

LED Recessed Troffer Retrofit Kit

RES+ Owner's Guide SMARTPHONE OPERATION KEY FOB OPERATION CT 200h TVIP V9 REMOTE ENGINE STARTER PLUS (RES+) OWNER S GUIDE

& Mattel and Smart Toy LLC. All Rights Reserved. and designate U.S. trademarks of Mattel, except as noted. DNV

56- Electric Latch Retraction Exit Devices Installation and Wiring Instructions

W1392. fisher-price.com


Paxton. ins us. Paxlock US

Apple, iphone and ipad are trademarks of Apple Inc., registered in the U.S. and other countries. Android is a trademark of Google Inc.

NWCTRL3024 INTELLIGENT SOLAR CHARGE CONTROLLER INSTALLATION AND OPERATION MANUAL. Thank you for purchasing NetWave from ComNet.

T

Low voltage transformer AGInode device REX2 single phase option. Introduction

Touchstone TB130 DC Output UPS

Table of Contents 20 Series Exit Device

BFK51 CFD40 CHM41. fisher-price.com

V-D2425 and V-D2440 Digital Clock

W9740. fisher-price.com. 2 Ride. 1 Sit. 3 Walk

W9740. Ride. Sit. Walk. fisher-price.com

W

268, 269 & 278. Concealed Door Closers

422 Series. Cam Action Door Closer

Installation & Programming Guide

Installation Instructions RF5010 and RF5210

WARNING. To prevent entanglement injury, never place gym in a crib or playpen. Never add strings, ties or other products to the gym.

Auto-Lift Operating System

X2916. fisher-price.com WARNING. Overhead Gym. Tummy Time Fun

Table of Contents Auxiliary Locks

2-WAY REMOTE STARTING SYSTEM WITH 1 BUTTONS FOR AUTOMATIC TRANSMISSION RED301-2WAY / ANT-2WDSS. User Guide For Key

Table Of Contents. 30 Series Exit Device. On The Cover

Axon Flex, Axon Flex 2, Axon Fleet, Axon Body, Axon Body 2, Axon Dock, and Axon Signal Vehicle Unit Warnings, Instructions & Information

R

W3599

T6339. Remove the mobile from the hub and clip to a stroller for on-the-go entertainment!

453X Series. Application. Features. Two-Position Damper Actuator General Instructions

20 Series. Exit Device

Motorized Electric Latch Retraction

Park Daddy Installation Manual

CONTENTS FIGURES GETTING STARTED 1 1 FUNCTIONS AND PARTS 2 1. IDH Max Service Manual

X7298. fisher-price.com WARNING

T Overhead Gym. Tummy Time Fun. On-the-Go Fun

7100SZ Series SafeZone Installation and Instruction Manual

*504471* Instruction Manual for the. Akrapovič Sound Kit. Sound Remote Controller and Akrapovič Car Sound Kit App Manual FOR CARS

CL3100 Series. Lever Lockset Parts Manual

Asymmetrical Installation Instructions. Components: i2cove Asymmetrical LED Light Fixtures. 12 [305mm] [918mm] 48.

626F Exit Device Trim Installation Instructions

Hendrickson Fit Adapter Installation Instructions

An ASSA ABLOY Group brand Series. Flatbar Exit Devices

WASP-P PRESSURE SENSOR

Installation and Wiring Instructions for the TL- Prefix SARGuide Illuminated Touchpad for 80 Series Exit Devices to ElectroLynx Connector System

1500 Series and 1600 Series Electric Strikes Installation Instructions

TRAC-Station BT Installation Instructions

Installation Manual. for Off Line Systems. INTELLIKEY is a trademark of INTELLIKEY Corporation GID 04/25/2003. Page 1

1500 Series and 1600 Series Electric Strikes Installation Instructions

CL3300 Series. Cylindrical Lockset Parts Manual

RIDESENSE User Manual

CHG26 IMAGINEXT. Requires four AA (LR6) alkaline batteries (not included) for operation.

CHG26 IMAGINEXT. Requires four AA (LR6) alkaline batteries (not included) for operation.

H3-EM Electronic Swinghandle Operating Instructions

Instruction Manual for the. Akrapovič Sound Kit. For BMW M2. Ver 1.0 / June 2016

4700LN Series ANSI/BHMA Grade 1 Certified Cylindrical Lever Locks. An ASSA ABLOY Group brand

V-DW2425A / V-DW2440 and V-DW11025A / V-DW11040A

Requirements LEO Power Operator Installation Instructions Patents: 5,881,497; 7,316,096; 7,484,333 CAUTION CAUTION WARNING

Transcription:

P1 PASSPORT 1000 Cylindrical Lock Installation Instructions A8033G 04/16 Copyright 2016, Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved. Reproduction in whole or in part without the express written permission of Sargent Manufacturing Company is prohibited.

1 2 3 4 5 6 7 8 Table of Contents Warning...2 General Description...3 Hardware Specifications...3 Electronic Specifications...3 Installation Wiring...4 Parts Breakdown...9 Installation Instructions...11 Operational Check...19! 1 FCC Warning Industry Canada: 1-800-810-WIRE www.sargentlock.com A8033G Changes or modifications to this unit not expressly approved by the party responsible for compliance could void the user s authority to operate the equipment. This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: Reorient or relocate the receiving antenna. Increase the separation between the equipment and receiver. Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. Consult the dealer or an experienced radio/tv technician for help. This Class B digital apparatus meets all requirements of the Canadian Interference Causing Equipment Regulations. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Cet appareillage numérique de la classe B répond à toutes les exigences de l interférence canadienne causant des règlements d équipement. L opération est sujette aux deux conditions suivantes: (1) ce dispositif peut ne pas causer l interférence nocive, et (2) ce dispositif doit accepter n importe quelle interférence reçue, y compris l interférence qui peut causer l opération peu désirée. This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance 20cm between the radiator and your body. This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter. Under Industry Canada regulations, this radio transmitter may only operate using an antenna of a type and maximum (or lesser) gain approved for the transmitter by Industry Canada. To reduce potential radio interference to other users, the antenna type and its gain should be so chosen that the equivalent isotropically radiated power (e.i.r.p.) is not more than that necessary for successful communication. Conformément à la réglementation d Industrie Canada, le présent émetteur radio peut fonctionner avec une antenne d un type et d un gain maximal (ou inférieur) approuvé pour l émetteur par Industrie Canada. Dans le but de réduire les risques de brouillage radioélectrique à l intention des autres utilisateurs, il faut choisir le type d antenne et son gain de sorte que la puissance isotrope rayonnée équivalente (p.i.r.e.) ne dépasse pas l intensité nécessaire à l établissement d une communication satisfaisante. Any retrofit or other field modification to a fire rated opening can potentially impact the fire rating of the opening, and SARGENT Manufacturing makes no representations or warranties concerning what such impact may be in any specific situation. When retrofitting any portion of an existing fire rated opening, or specifying and installing a new fire-rated opening, please consult with a code specialist or local code official (Authority Having Jurisdiction) to ensure compliance with all applicable codes and ratings. To avoid possible damage from electrostatic discharge (ESD), some basic precautions should be used when handling electronic components: Minimize build-up of static by touching and/or maintaining contact with unpainted metal surfaces such as door hinges, latches, and mounting plates especially when mounting electronic components such as readers and controllers onto the door. Leave components (reader and controller) protected in their respective anti-static bags until ready for installation Do not touch pins, leads or solder connections on the circuit boards

2 General Description An ANSI/BHMA Grade 1 lock utilizing Power over Ethernet (PoE) technology, the Passport 1000 P1 provides a cost-effective, future-proof solution for campuses. Featuring multiclass SE Technology from HID Global, it provides simultaneous support for multiple credentials and offers an easy migration path to higher security credentials and mobile access. Recognized for its contribution to sustainable buildings, the P1 re-uses existing IEEE 802.3af PoE infrastructure, streamlines the installation process, reduces costs and components, and minimizes power consumption. 3 Hardware Specifications Complete locksets with controller Easily retrofits existing Passport 1000 (cylindrical lock) door preps ADA Compliant Latch 1/2 standard 3/4 throw fire-rated double doors (optional) (41- prefix) Deadlocking latch Inside lever retracts latch Outside lever is unlocked through access control credentials only Outside lever controlled by any combination of keypad, magnetic swipe, contactless reader or mechanical cylinder May be used for indoor and outdoor applications ANSI/BHMA A156.25 Listed Grade 1 Compliant NOTE: A weather-protective gasket is required for outdoor applications. 4 Electronic Specifications HID multiclass SE technology offers support for the following credentials: 2.4 GHz credential compatibility: Secure Identity Object (SIO) on Mobile IDs (Bluetooth Smart) 13.56 MHz credential compatibility: iclass iclass SE (SIO-enabled) iclass Seos SIO on MIFARE Classic SIO on MIFARE DESfire EV1 MIFARE Classic DESfire EV1 NFC-enabled mobile phones 125 khz credential compatibilty: HID Prox Power Requirements: 55VDC, 90mA PoE Class 1 Device, as defined by IEEE 802.3af, requires less than 3.84 watts over structured cabling Multiple time zone and holiday access scheduling First-in unlock or automatic unlock configuration, based on specified time schedule 2,400 users per lock; 10,000 event audit trail Privacy button UL Listed* - UL294 Indoor Use CUL Listed - S319: Class 1 UL 294 Access Control Ratings: Destructive Attack Level 1 Line Security Level 1 Endurance Level 4 Standby Power Level 1 Magnetic Stripe *UL testing was conducted on product powered by UL Listed model 9001GR/AC injector; manufactured by Microsemi Corp. 1-800-810-WIRE www.sargentlock.com A8033G 3

5 Installation Wiring Overview SARGENT Passport Series PoE P1 Typical Application Network Switch (802.3af) Network Cable Surface Mount RJ45 LMT: Lock Management Tool A A. PoE frame harness assembly B. PoE data hinge from McKinney C. PoE door harness* from McKinney D. Passport 1000 P1 PoE Lock E. DPS: Door Position Switch (Needed on Cylindrical and Exits only) * Door width determines length B C D E 4 1-800-810-WIRE www.sargentlock.com A8033G

Installation Wiring (Continued) Supplied by CI B-Splice Crimp Connector Certified Integrator (CI) supplies and terminates the B-Splice connector and the male RJ45 connector from harness to end user provided facility cable Patch Cable Patch Panel to PoE Switch To building or electrical ground Supplied by End User PoE Switch PoE Switch is Terminated to Earth Ground Ceiling RJ45-M RJ45-F Jack Cable: CAT 5e or higher 24 AWG Patch Panel Frame-Side Harness Assembly (15' length) Cable: CAT 5e or higher 24 AWG 100ohm Molex-M A Molex-F B Molex-F Molex-M Cable: CAT 5e, 26 AWG stranded, 100ohm Ground Ring Terminal Secured to Lock Mounting Plate Wiring to TIA/EIA 568-B Standard NOTE: TIA/EIA 568-B added only at lock side C RJ45-M D PoE Lock Notes: Approved Software Connectors go on only one way. They cannot be placed in an incorrect position. Do not force and do not offset connectors Be sure they are completely seated (flush) PoE power source cannot be connected to a receptacle controlled by a switch 1-800-810-WIRE www.sargentlock.com A8033G 5

Installation Wiring (Continued) A Frame Harness Installation Supplied by CI B-Splice Crimp Connector Components and wire harness supplied by McKinney. Suggested installation: Cut end / ceiling-side PoE harness: TIA/EIA 568-B Standard Wiring Ceiling 24AWG Stranded Drain Wire for Earth Ground in 15' Frame Harness Frame-Side Harness Assembly (15' length) B Molex-M RJ45-M Cable: CAT 5e or higher 24 AWG 100ohm PoE Data Hinge Frame 4-pin M 6-pin M 1 2 3 4 5 6 7 8 Do not confuse pair numbers with pin numbers. A pair number is used for reference only (eg: 10BaseT Ethernet uses pairs 2 & 3). The pin numbers indicate actual physical locations on the plug and jack. Hinge side of PoE harness: 1. Feed cut end of harness into hole on hinge-side through single access hole. 2. Push one connector back through the hole and feed into the other access hole. Each of the hinge-side harness connectors should end up threaded through a different access hole and matched to the same size pin connector from the door harness: 4-pin F 6-pin F 4-pin male molex connector 6-pin male molex connector with ground wire PoE Hinge 4-pin F 1 pin 8 8 pin 1 6-pin F PIN Wire Pair Number 1 White/Orange 2 2 Orange 2 3 White/Green 3 4 Blue 1 5 White/Blue 1 6 Green 3 7 White/Brown 4 8 Brown 4 Hinge-side harness connectors: 4-pin female molex connector 6-pin female molex connector with ground wire Lock-side harness connectors: 4-pin female molex connector 6-pin female molex connector with ground wire 6 1-800-810-WIRE www.sargentlock.com A8033G

C Hinge Installation Order of installation may vary. Refer to appropriate sections for instructions. Hinge-side harness connectors: 4-pin male Molex connector 6-pin male Molex connector with ground wire Lock-side harness connectors: Ring terminal Male RJ45 connector (crimped after cable is fed through door) Notes: Connectors go on only one way. They cannot be plugged to incorrect position. Do not force and do not offset connectors. Be sure they are completely seated (flush). PoE Lock 4-pin F 4-pin F 4-pin M RJ45-M 6-pin F 6-pin F 6-pin M Cable: CAT 5e, 26 AWG stranded, 100ohm D PoE Door Harness Order of installation may vary. Refer to appropriate sections for instructions. 1. Prop door open. 2. Using the ring terminal, carefully route the assembly through the door channel to the lock. PoE Harness (Cat 5e) 1-800-810-WIRE www.sargentlock.com A8033G 7

E DPS (Door Position Switch) Installation 1. Prep door according to proper template (Fig. D1). 2. Insert connector end of DPS through the raceway on the latch edge of the door (Fig. D2). Note: Only use collar when installing in a metal door. 3. To insert DPS, push wires through raceway toward lock prep. 4. Push DPS firmly into place by hand. IMPORTANT: DO NOT TAP SWITCH WITH ANY TOOL. Inside of Door Collar is used only with metal doors. Door Position Switch (DPS) DPS Harness Door Position Switch Hole Dim 1 Dim 1 Vertical of Strike Dim 2 (See template) Horizontal of Strike Fig. D1 Wood Frame Metal Frame Dim 1 3/8 3/4 Strike for Cylindrical Lock Fig. D2 8 1-800-810-WIRE www.sargentlock.com A8033G

6 Parts Breakdown P1 PoE Lock with Magnetic Card Swipe With or Without Keypad 3 4 1 2 5 ITEM No. PART No. DESCRIPTION 1 52-3583-[finish] Outside Escutcheon Assemby, mag stripe 52-3582-[finish] Outside Escutcheon Assemby, mag stripe and Keypad (shown) 52-4244-[finish] Outside Escutcheon Assemby, Mag Swipe, Keypad, and HID 125 khz Prox 52-4759-[finish] Outside Escutcheon Assemby, iclass, keypad, mag stripe, Prox, smart card (MIFARE, DESFIRE) 52-4777-[finish] Outside Escutcheon Assemby, iclass, mag stripe, Prox, smart card (MIFARE, DESFIRE) 52-4787-[finish] Outside Escutcheon Assemby, FeliCa, keypad, mag stripe, Prox 52-4788-[finish] Outside Escutcheon Assemby, FeliCa, mag stripe, Prox 52-4894-[finish]* Outside Escutcheon Assemby, Standard Reader and Keypad 52-4895-[finish]* Outside Escutcheon Assemby, Standard Reader 52-4896-[finish]* Outside Escutcheon Assemby, Felica Reader and Keypad 52-4897-[finish]* Outside Escutcheon Assemby, Felica Reader 2 52-4779 Mounting Plate Assembly 3 52-4940 PoE Controller Assembly 4 52-4776-[finish] Inside Escutcheon Assembly with Privacy Button 5 52-5373 Door Position Switch Kit *Bluetooth Smart option 1-800-810-WIRE www.sargentlock.com A8033G 9

Parts Breakdown (Continued) 10 Line Series Cylindrical Lock 7a 11 5 4 12 1 2 3 4 5 6 7 8 * 9 10 *Adapter Plate/Spacer (10-0847) is only shipped with orders that specify 1-3/8 doors. ITEM PART No. DESCRIPTION REQ D 1 --- Outside Lever (Reference Catalog for Available Styles) 1 2 10-0043 Lever Retainer Key (In Screw Pack 10-2052) 1 3 --- Cylinder Assembly (Reference Catalog for Available Cylinders) 1 4 --- Rose (Reference Catalog for Avalable Styles) 2 5 10-0792 Spacer Bushing 2 6 10-3049 Outside Rose Spring Assembly 1 7 10-3449 Lockbody Assembly 10G77 - Standard Cylinder 1 10-3450 Lockbody - LFIC 1 10-3451 Lockbody - SFIC 1 7a 52-4844 Lockbody Harness 1 8 10-0847 Adapter Plate/Spacer (*Only Included With 1-3/8 Thick Doors) 1 9 10-3192 Latch Assembly 1 10 10-2052 Screw Pack 2 11 10-3048 Inside Rose Spring Assembly 1 12 --- Inside Lever (Reference Catalog for Available Styles) 1 Tools Required: #2 Phillips screwdriver Flat head T20 security pin Torx driver 10 1-800-810-WIRE www.sargentlock.com A8033G

7 Installation Instructions 1 Door Preparation A. Verify Hand and Bevel of Door Left Hand Hinges Left. Open Inward. LH Left Hand Reverse Bevel Hinges Left. Open Outward LHRB Right Hand Hinges Right. Open Inward. RH Right Hand Reverse Bevel Hinges Right. Open Outward. RHRB B. Verify Product Label C. Door Preparation Prior to installation, all holes must be free of burrs, debris and sharp edges. If doors are not properly reinforced per ANSI115.2, commercially available reinforcements should be installed. Prepare door according to appropriate template, (refer to website www.intelligentopenings.com): Field template: A8066 with DPS and A8067 without DPS. Door manufacturers templates: 4652 with DPS and 4658 without DPS. Escutcheon Through Bolt Holes Raceway for PoE Controller Wire Hole Lockbody Through Bolt Holes Alignment Notches Lock Body Prep Outside of Door Door Position Switch Latch Front and Hole Fig. 1 Inside of Door Escutcheon Through Bolt Holes Inside Mouthing Plate Holes Raceway for PoE Controller Wire Hole Wire Run Channel Lock Body Through Bolt Hoes Alignment Notches Lock Body Prep 1-800-810-WIRE www.sargentlock.com A8033G 11

2 Install Strike Install strike in the door frame (Fig.2). Fig. 2 3 Install Latch Bolt 1. Install latch with beveled bolt facing strike. 2. Attach with two screws. DO NOT tighten completely at this time. PoE Harness (Cat 5e) Outside of Door IMPORTANT: Latch bevel must match door bevel and deadlocking latch must stop on strike when door is closed. Strike Deadlocking Latch Fig. 3B Detail IMPORTANT: Door must remain open during installation. Use door stop. Fig. 3 DPS Cable Latch Assembly (2) #8-32 x 3/4 Combination Screws 12 1-800-810-WIRE www.sargentlock.com A8033G

4 Lock Presets and Adjustments A. Lock Preset Lockbody holes 12 and 6 o clock (Fig. 5A). Door thickness 1-3/4 thick. Refer to adjustments below for other door conditions (Fig. 4B). B. Through-Bolt and Door Thickness and Adjustment Remove outside lever (Fig 4A), scalp and spacer bushing. Rotate mounting plate to either align with through-bolt holes in door or adjust for proper door thicknesses (Fig. 4A and 4B). See markings on through-bolt post. Re-install spacer bushing (to align with back of lever), scalp and lever. 1-3/4 Thick Doors 2 Thick Doors Lock Body Holes Fig. 4A Rotate to match lock body holes in door. Fig. 4B Detail C. How To Remove Outside Lever (If Necessary) 1. Insert key, rotate 45 clockwise and hold (Fig. 4C). 2. Depress lever retainer with push pin tool (provided). D. How To Change Cylinder (If Necessary) 1. With outside lever in hand, use standard pliers to pull out cylinder retainer. 2. Remove key and cylinder from lever. 3. Insert new cylinder. 4. Secure by pressing cylinder retainer flush. Cylinder Retainer Cylinder Fig. 4C Fig. 4D Outside Lever 1-800-810-WIRE www.sargentlock.com A8033G 13 Key

5 Install Lock Body IMPORTANT: If lock is being installed as a retrofit; (replacing an existing P1 product), remove the DPS wires and connector (Fig. 5A) by simply severing the wires as indicated* (see arrow). If this is a new lock being installed for the first time, DO NOT REMOVE wires and connector. 1. Feed wires followed by the lockbody from outside of door through the lockbody hole (Fig. 5A). 2. Lockbody must engage both the latchbolt unit prongs and tail piece (Fig. 5B). Wire Harness (From Lock Body) PoE Harness (Cat 5e) DPS Cable Fig. 5B Detail Cylindrical Lock Body and Outside Trim Cut wires here* Fig. 5A 6 Secure Lock To Door 1. Feed wire and connector: For wood door, feed connectors and wires through the door and up the wire run channel (Fig. 6A). For metal door (not shown), feed connectors and wires into the lockbody hole and out the controller hole. 2. Position ground lug between (top) #10-32x1-1/4 through-bolt and rose assembly (Fig. 6A). NOTE: Proper placement of ground wire (Fig. 6B) will prevent pinching/damage to the ground wire. 3. Secure rose assembly with (2) #10-32x1-1/4 through-bolts. 4. Secure latch by fully tightening (2) #6 x 3/4 self-tapping screws (refer to previous section 3 - Install Latchbolt). Fig. 6A Fig. 6B Detail Spring housing assembly Wire Harness (From Lockbody) Put top flat head screw through ground ring terminal and tighten down (2) #10-32 x 1-1/4 Flat Head Machine Screws (to secure outer spring housing) 14 1-800-810-WIRE www.sargentlock.com A8033G

7 Assemble Inside Trim 1. Verify spacer bushing is inserted horizontally and aligned with lever (Fig. 7). 2. Place rose (scalp) over shaft of lock body against surface of door; hand-tighten, turning clockwise. 3. Attach lever. Push until engaged. DPS (Door Position Switch) PoE Harness from Hinge (with ground wire) Inside of door Spacer Bushing Fig. 7 Rose (Scalp) Inside Lever 8 Install Wire Cover Plate (Wood Door Only) 1. Position the wire cover plate above the rose and covering the wire channel. Mark the hole positions. 2. Ensure stamped side of plate is against the door. 3. Drill (2) 3/32 diameter by 1/2 deep holes (Fig. 8A). 4. Cover wires with cover plate by securing plate to door directly above rose using two (2) #6 x 1/2 flat head security torx wood screws (Fig. 8A). Note: Tuck wires and ferrite in hole at top of wire channel (Fig. 9A). Position lower edge of cover plate against the rose to ensure no wires are visible and make sure the plate is oriented correctly (Fig. 8B). Fig. 8B Detail Back Side of Wire Cover Plate Fig. 8A Inside of door Wire Cover (2) #6 x 1/2 Flat Head Security Torx Wood Screws This Side Down 1-800-810-WIRE www.sargentlock.com A8033G 15

9 Install Gasket (Optional) and Install Outside Escutcheon Note: Gasket optional, for non-fire rated doors only. For non-fire rated door applications, an optional gasket (Part number 52-0782) may be used as a weather seal between the escutcheon and the outside door surface. Outside of Door Peel off adhesive backing and attach to (outside) escutcheon. Gasket 1. Position the outside escutcheon, aligning the posts with the door prep (Fig. 9). 2. Feed reader cable through opening. Reader Cable Outside Escutcheon 10 Mounting Plate Assembly 1. On the inside of the door, position the mounting plate over the indicated holes. 2. Feed reader, ground ring terminal and DPS cables through central opening on mounting plate (Fig. 10). 3. Route PoE Harness through alternate opening (to the right of the central opening). 4. Route ground ring terminal from lock body through bottom of mounting plate and attach to bottom left corner using (1) #8-32 x 1-7/8 flat head machine screw. 5. Insert other three #8-32 x 1-7/8 flat head machine screws and tighten, fastening the outside escutcheon to the door (Fig. 10). IMPORTANT: If the following step is skipped, the product will not be UL-compliant: 6. Attach two (2) #8 x 3/8 flat head wood screws for wood doors or (2) #8-32 x 3/8 flat head machine screws for metal doors (Fig. 10). Fig. 9 Fig. 10 Ground Lugs Mounting Plate (4) #8-32 x 1-7/8 Flat Head Machine Screws (2) #8-3/8 flat head Wood Screws PoE Harness 16 1-800-810-WIRE www.sargentlock.com A8033G

11 Installation of Connectors CAUTION - Do not touch or allow debris to enter connector contacts. Secure the following connectors to their respective terminals (Fig. 11A): A. Secure the 4-pin DPS connector. B. Secure the 10-pin lock body assembly connector. IMPORTANT: Do not run wires through bottom hole in plate (Fig. 11A) - it will damage wires and the controller connector. Route wires around flange, do not route wires through the flange hole (Fig. 11A). Secure Mounting Plate 1. Tuck excess cable into wire hole on inside of door. 2. Secure the mounting assembly while ensuring proper alignment of outside reader and fully tighten the (2) throughbolts on the inside of the door to secure the reader and plate to the door. C. Secure the 24-pin card reader connector (Fig. 11A). Reader (24-pin) C A B DPS (4-pin) D. Crimp* RJ45 to Cat 5e cable from hinge (Fig. 11B). *For more detail, refer to section (5) Installation Wiring, A - Frame Harness Installation. Ground Lugs 1 2 3 4 5 6 7 8 TIA/EIA 568-B Standard Wiring 1 pin 8 8 pin 1 PIN Wire Pair Number 1 White/Orange 2 2 Orange 2 3 White/Green 3 4 Blue 1 5 White/Blue 1 6 Green 3 7 White/Brown 4 8 Brown 4 Do not confuse pair numbers with pin numbers. A pair number is used for reference only (eg: 10BaseT Ethernet uses pairs 2 & 3). The pin numbers indicate actual physical locations on the plug and jack. Board-to-Board Connector Fig. 11A Cat 5e cable from hinge Fig. 11B Lock Body (10-pin) RJ45-M Crimp* to RJ45-M Connector D 1-800-810-WIRE www.sargentlock.com A8033G 17

12 Installation of Inside Module Component Assembly 1. Insert top tabs of controller into slots on mounting plate (Fig. 12A). 2. Ensure proper alignment of board-to-board connectors while pivoting bottom of controller toward door until tab on bottom snaps securely into place on mounting plate. CAUTION: To avoid possible damage to board-to-board connectors, care should be taken when securing controller to mounting plate. If there is resistance when securing, detach controller to determine cause before re-attaching controller. 3. Connect RJ45 male Connector to female RJ45 on controller board (Fig. 12B, C). 4. Remove pull tab from its position beneath the coin cell by pulling on tab in direction of arrows printed on tab (Fig. 12B, C). Coin Cell Pull Tab Fig. 12B Fig. 12A Fig. 12C Coin Cell Pull Tab 18 1-800-810-WIRE www.sargentlock.com A8033G

13 Installation of Inside Escutcheon 1. Position inside escutcheon (Fig. 13). 2. Insert screws, top and bottom, and tighten securely. DO NOT OVERTIGHTEN. Note: All wires should be placed inside to avoid pinching. 3. Straighten escutcheon and tighten securely. (2) #8-32 x 1/2 Secure Torx Machine Screws Fig. 13 8 Operational Check IMPORTANT: Be sure to test functions prior to closing door. In all cases, perform the following checks: 1. Ensure that inside lever retracts latch. For units with cylinders, the following checks apply: Insert key into cylinder and rotate: a. There should be no friction against lock case or any other obstructions. If friction or binding occurs, re-adjust cylinder to eliminate issues. b. The key should retract the latch and the key should rotate freely. c. The key should extend and retract the deadbolt. For units without a keypad, add card using LCT software* and test. For units with a keypad, add pin and card using LCT software* and test. 2. LED signaling: After using a valid credential, a green flash followed by three fast amber flashes indicates a low power condition. Check the input voltage. If the input voltage is low, disconnect the lock from the power source and check the power source voltage. If the power source voltage is correct, inspect the lock wiring for a possible short. If the lock loses power, it will flash rapid blue for approximately one minute. Lock will default to programmed fail safe or fail secure. After that, the lock will no longer be functional. 3. When you have completed the tests, close the door, ensuring latchbolt fully extends into strike plate without binding. *Refer to Network and Lock Configuration Tool user manual (WFMN1) for information on how to configure and program locks. 1-800-810-WIRE www.sargentlock.com A8033G 19

SARGENT Manufacturing 100 Sargent Drive New Haven, CT 06511 USA 800-810-WIRE (9473) www.sargentlock.com HID and iclass are registered trademarks of HID Global Corporation. Founded in the early 1800s, SARGENT is a market leader in locksets, cylinders, door closers, exit devices, electro-mechanical products and access control systems for new construction, renovation, and replacement applications. The company s customer base includes commercial construction, institutional, and industrial markets. Reproduction in whole or in part without the express written permission of Sargent Manufacturing Company is prohibited. ASSA ABLOY is the global leader in door opening solutions, dedicated to satisfying end-user needs for security, safety and convenience. A8033G -04/16