JUNG PUMPEN US SUBMERSIBLE DRAINAGE PUMPS

Similar documents
10 mm free passage. Submersible drainage pumps US Application. Safe to run dry. Easy to maintain with guide rail system. 10 mm free passage

JUNG PUMPEN COMPLI 1500 / 2500 SEWAGE LIFTING STATIONS

jung pumpen CATALOGUE RESIDENTIAL TECHNOLOGY RELEASE 20

JUNG PUMPEN MULTICUT SEWAGE PUMPS

JUNG PUMPEN compli 100 MC Sewage lifting stations

JUNG PUMPEN COMPLI 100 MC SEWAGE LIFTING STATIONS

Grey Water and Condensate Pump. Rotex. Type Series Booklet

Poly-sump PKS-B 800 for submersible sewage pumps With plastic valves and guide rail. Application. Description

JUNG PUMPEN BAUFIX 200. Instruction Manual

Series description: Wilo-Drain STS 40

Series description: Wilo-Drain MTC

DP A.2.50B. Grundfos pump GRUNDFOS DATA BOOKLET

Sewage transport Submersible pumps

Instruction Manual. Sewage lifting station compli 300

Design details Design. Installation types. Shaft seal. Impeller type. Drive. Bearings

VX-ST VORTEX. Submersible pumps in stainless steel. PERFORMANCE RANGE Flow rate up to 650 l/min (39 m³/h) Head up to 15 m

COLLECTION STATIONS AND WASTE WATER LIFTING DESIGN SPECIFICATIONS

ABS submersible sewage pump AFP

Technical Data BEST 2~5. Stainless Steel Submersible Sump Pumps EBARA PUMPS AUSTRALIA PTY. LTD. Best 2-5_Techdata_SS_V10

Sealless Magnetic Coupled Hot Oil Circulation Pumps acc. to DIN EN / ISO 2858 Type NMWR / NMWB / NMW. our. contribution for

Pump Station. Ama-Porter CK Pump Station. Type Series Booklet

LITERS PER MINUTE GALLONS PER MINUTE

JUNG PUMPEN CONTROL UNITS

Pump Specifications LE100-Series 1HP Submersible Sewage Pump

Electric submersible pumps SEMISOM for sewage water

Series description: Wilo-Drain TM/TMW/TMR 32

Dewatering Submersible sewage pumps

Pump Specifications. Omnivore 2HP Submersible Grinder Pumps LSG200-SERIES (SINGLE STAGE) LSGX200-SERIES (TWO STAGE)

Pump Specifications. D3648LSG, D3648LSGX Series Omnivore 2HP Duplex Grinder Packages LITERS PER SECOND

HOMA Product Range. Electric Submersible Sewage Pumps Ranges K, KX. The source for world wide pump technology. Discharge Size DN 200 up to DN 400

SE M.C.N.51D

NOTE: LEH100-Series high-head pumps require a minimum application of 15' head. Do not use pump in this area use a smaller pump.

Drainage pumps Series KEP

SL B. Grundfos pump GRUNDFOS DATA BOOKLET

Electric submersible pumps SEMISOM for sewage water

XLE50 FLOW RATE (LPM) Flow Rate (GPM)

Series description: Wilo-Drain TM/TMW/TMR 32

LITERS PER MINUTE TOTAL HEAD IN FEET TOTAL HEAD IN METERS GALLONS PER MINUTE

MODEL Kg H x W x L mm LM/HM kw CODE PRICE

Pump Specifications LE40 Series 4/10 HP Submersible Sewage Pump Pump

SKHS SERIES 2 HP 1-1/2 HP 1 HP 1/2 HP CAPACITY-U.S. G.P.M.

Pump Specifications. LE50 Series ½ HP Submersible Sewage Pump

Pump Specifications 250 Series Submersible Sump / Effluent Pump

Pump Specifications LE70-Series 3/4 HP Submersible Sewage Pump

Pump Specifications FL150 Series Submersible Effluent Pump

Pump Specifications LE70-Series 3/4 HP Submersible Sewage Pump

Pump Specifications FL50 Series 1/2 hp Submersible Effluent Pump

SKV40. Performance Data. Wholesale Products Page: Section: Performance Data Dated: January RPM: 1550 Discharge: 2" Solids: 2" GPM: TDH:

50 Hz PX CHANNEL 1. Performance curves. data refered to : W ater, pure [100%] ; 20 C; 0,9983kg/ dm³; 1,001mm²/ s. Tolerances acc.

TRITUS. Submersible pumps with grinder

ECC ECC Flow(USGPM) Sump & Effluent De-watering Drainage. Phase Voltage Approx Weight (lbs)

Waste Water, Condensate and Heat Transfer Fluid Pump. Type Series Booklet

SUBMERSIBLE PUMPS EFFLUENT DISPOSAL RANGE 4 poles - 50 Hz

HYDROMATIC SKHS SERIES SUBMERSIBLE NON-CLOG, SEWAGE EJECTOR

Drainage pumps Series KEP

ELECTRIC SUBMERSIBLE SIBLE SEWAGE PUMPS. Ranges MX, V, K Discharge Size DN 80 - DN 150

Technical Data DML. Submersible Sewage Pumps with Single Channel Impeller. DML_Techdata_SS_V11 EBARA PUMPS AUSTRALIA PTY. LTD.

XFL70 FLOW RATE (LPM) Flow Rate (GPM)

Data sheet: Wilo-Drain TP 65 F 91/11 (1~230 V)

SUBMERSIBLE SEWAGE AND EFFLUENT PUMPS

Unilift CC 7-A1 (240V,0.25kW, L/sec,1-7m)

SPD50H/100H. Performance Data SPD100H SPD50H. Wholesale Products Page: Section: Performance Data Dated: April 2002 Supersedes: January 2001

Side channel pumps ADH/CDH AEH TECHNICAL DATA. Temperature: max. 120 C. PN 40 for AEH

Data sheet. Page: 1 / 5. ETL GGSAV11D BKSBIE3 Inline pump. Operating data. Design

GRUNDFOS DATA BOOKLET AP, KP. Wastwater pumps 50 Hz

Page - SPECIFICATIONS 200 SELECTION CHART 201 TYPE KEY 201 CURVE SPECIFICATIONS 202 PERFORMANCE CHART IDROGO PERFORMANCE CHART IDROGO

Dewatering pumps for raw water pumping. / / grundfos DW RANGE

Page - CONSTRUCTIONS 300 SECTIONAL VIEW 300 MECHANICAL SEAL DIMENSIONS AND WEIGHT 400 PUMP 400 PACKING TECHNICAL DATA 500

Data sheet. Etaline GN /3002 G11 Version no.: 1 Inline pump. Operating data. Design. Clean water. Efficiency 61.6 % 20.0 C.

Automatic Waste Water Pump Station. Evamatic-Box N. Type Series Booklet

Pump Specifications FL60/FLH60 Series 6/10 hp Submersible Effluent Pump

Pump Specifications 290 Series 3/4 hp Submersible Effluent Pump

MYERS 3MW VERTICAL DISCHARGE WASTEWATER PUMPS. Sewage, high-capacity sump, effluent

Pump Specifications 280 Series 1/2 hp Submersible Effluent Pump

Waste Water, Condensate and Heat Transfer Liquid Pump. Type Series Booklet

HYDROMATIC SPD50H/100H SUBMERSIBLE HIGH HEAD, DOUBLE SEAL EFFLUENT

ELECTRIC SUBMERSIBLE PUMPS SEMISOM/80

Ama-Drainer-Box Type Series Booklet

VERTICAL IN-LINE PUMP

KW Submersible, Single-Vane Impeller

SUBMERSIBLE PUMP RANGE

SEV D. Grundfos Pump GRUNDFOS DATA BOOKLET

- CONTENTS SPECIFICATIONS 200 SELECTION CHART 201 PERFORMANCE CHART IDROGO PERFORMANCE CHART IDROGO

ELECTRIC SUBMERSIBLE SIBLE SEWAGE PUMPS. Rangess AK, KXAKX Discharge Size DN 200 DN

HYDROMATIC SK75/100 SUBMERSIBLE SEWAGE EJECTOR

Priox. The new range NOCCHI. Lenntech NOCCHI. Tel Fax waste water treatment

Ama Porter. 50 Hz. Submersible motor pumps

Aqualift F XL Lifting Stations

SDL i MACERATING SUBMERSIBLE PUMPS

Volute Casing Centrifugal Pumps in In-line Design with Magnetic Drive. Series CNI-M

Position Qty. Description Single Price

Side channel pumps PN 16 SOH - SOHB. Self-priming centrifugal pumps. Technical description

- CONSTRUCTIONS 300 SECTIONAL VIEW 300 MECHANICAL SEALS 301 BEARINGS DIMENSIONS AND WEIGHT 400 PUMP 400 PACKING TECHNICAL DATA 500

OIL SMART PLUG AND PLAY SYSTEM, Model #OSS-100

Data sheet. Etaline GN /1852 G10 Version no.: 1 Inline pump. Operating data. Design. Requested developed head m

DRD - DRS - DRF. SUBMERSIBLE ELECTRIC PUMPS FOR SEWAGE in cast iron

XFLO XS SERIES. Single Stage Double Suction Split Casing Centrifugal Pump

HTM Circulation Pumps acc. to DIN EN 733 Type NKLs

.2 Section Waste Management and Disposal..5 Section Thermometers and Pressure Gauges Piping Systems.

GY/UY GRINDER / VORTEX SERIES

Transcription:

APPLICATION The centrifugal submersible drainage pumps US 62-251 can be used wherever sewage water with solids up to 10 mm particle size occurs, e.g. in collecting sumps for ground water, or in permanent draining systems for clean water, or handling solids in suspension. They are also ideal for pumping the sewage water from collecting sumps into which dishwashers or washing machines are discharging. For high temperature hot water in the industrial and commercial field we recommend the use of our US 73 and US 103 HE/HES. This range of pumps is suitable for stationary and portable use. For easy removal of the pumps from deep sumps we recommend the use of our guide rail systems which provide ease of maintenance and inspection. For automatic monitoring of the oil chamber a seal leak control can be connected. Maximum cable length of the pumps is 10 m. 3-phase pumps with level control (US DS, US 152 DS and US 251 DS) have a CEE-Plug with phase inverter. Safe to run dry Easy to maintain due to guide rail systems 10 mm free passage PERFORMANCE US 251 D US 62 ES Controllable oil chamber SiC mechanical seal independent of rotation direction Replaceable moisture sealed cable inlet The sewage pumps are tested by the German Institute for Construction Engineering and correspond to the valid construction and test principles. 25696-03 We reserve the right to change specifications without notice Pump performance is subject to ISO 9906 tolerances The minimum flow velocity in the pressure piping must be 0.7 m/s according to EN 12056. This data is represented in the performance curve as a limit of application. D 117 3.2-EN 1501 1

US 62 251 Type Maximum Height x Width x Depth Discharge branch Free passage Cable quality H07RN-F- Cable length with plug Cable ength without plug Weight approx. Code No. Pumps without level control US 62 E 380 x 190 x 210 mm 1½ 10 mm 3G1.0 10 m 12.6 kg JP09812 US 62 D 380 x 190 x 210 mm 1½ 10 mm 4G1.0 10 m 12.8 kg JP09813 US 102 E 410 x 190 x 210 mm 1½ 10 mm 3G1.0 10 m 14.5 kg JP09278 US 102 D 410 x 190 x 210 mm 1½ 10 mm 4G1.0 10 m 15.0 kg JP00214 US 152 E 435 x 190 x 210 mm 1½ 10 mm 3G1.0 10 m 16.0 kg JP09435 US 152 D 435 x 190 x 210 mm 1½ 10 mm 4G1.0 10 m 17.0 kg JP09437 Pumps with built-in level control US 62 ES 380 x 225 x 325 mm 1½ 10 mm 3G1.0 10 m 12.7 kg JP09814 US 62 DS 380 x 225 x 325 mm 1½ 10 mm 4G1.0 10 m 12.9 kg JP09815 US 102 ES 410 x 225 x 325 mm 1½ 10 mm 3G1.0 10 m 14.5 kg JP09279 US 102 DS 410 x 225 x 325 mm 1½ 10 mm 4G1.0 10 m 15.0 kg JP00218 US 152 ES 435 x 225 x 325 mm 1½ 10 mm 3G1.0 10 m 16.0 kg JP09436 US 152 DS 435 x 225 x 325 mm 1½ 10 mm 4G1.0 10 m 17.0 kg JP09438 Pumps without level control US E 360 x 220 x 310 mm 2 10 mm 4G1.0 10 m 27.0 kg JP09310 US D 360 x 220 x 310 mm 2 10 mm 6G1.5 10 m 27.5 kg JP09300 US 251 D 360 x 220 x 310 mm 2 10 mm 6G1.5 10 m 27.5 kg JP09301 Pumps with built-in level control US ES 360 x 220 x 310 mm 2 10 mm 4G1.0 10 m 29.0 kg JP09241 US DS* 360 x 220 x 310 mm 2 10 mm 6G1.5 10 m 29.5 kg JP09243 US 251 DS* 360 x 220 x 310 mm 2 10 mm 6G1.5 10 m 29.5 kg JP09245 * CEE-Motorprotection with phase inverter PERFORMANCE Type Delivery head H [m] 1 2 3 4 5 6 7 8 9 10 11 12 13 14 16 US 62 E/ES 19 17 15 12 10 8 6 4 2 Flow rate Q [m3/h] US 62 D/DS 22 20 17 15 12 10 8 6 4 US 102 E/ES/D/DS 28 26 23 21 19 17 15 12 10 8 5 2 US 152 E/ES 30 29 27 24 22 20 18 15 13 11 8 6 3 1 US 152 D/DS 31 30 28 26 23 21 19 17 14 12 10 8 5 3 US E/ES/D/DS 40 39 37 35 33 31 29 26 23 20 17 14 US 251 D/DS 54 52 51 49 47 45 43 40 38 35 32 29 25 21 10 ELECTRICAL DATA Type Type of current Voltage Motor rating kw RPM Current Motor protection Plug Volt P1 P2 min-1 Ampere US 62 E/ES 1-phase 1/N/PE~230 0.83 0.50 2510 3.9 integrated Safety- US 62 D/DS 3-phase 3/PE~400 0.85 0.60 2800 1.4 integrated CEE- US 102 E/ES 1-phase 1/N/PE~230 1.37 0.98 2700 6.0 integrated Safety- US 102 D/DS 3-phase 3/PE~400 1.36 1.06 2740 2.4 integrated CEE- US 152 E 1-phase 1/N/PE~230 1.60 1.21 2814 7.5 bauseits* US 152 ES 1-phase 1/N/PE~230 1.60 1.21 2814 7.5 integrated Safety-** US 152 D 3-phase 3/PE~400 1.70 1.41 2815 3.1 bauseits* US 152 DS 3-phase 3/PE~400 1.70 1.41 2815 3.1 integrated CEE-** US E 1-phase 1/N/PE~230 1.68 1.19 2812 7.6 bauseits* US ES 1-phase 1/N/PE~230 1.68 1.19 2812 7.6 integrated Safety-** US D 3-phase 3/N/PE~400 1.60 1.30 2925 3.0 bauseits* US DS 3-phase 3/N/PE~400 1.60 1.30 2925 3.0 integrated CEE-** US 251 D 3-phase 3/N/PE~400 2.60 2.10 2860 4.4 bauseits* US 251 DS 3-phase 3/N/PE~400 2.60 2.10 2860 4.4 integrated CEE-** * additional requirements. see technical data or accessories ** Protective motor plug 2

Dimensions US 62, US 102 and US 152 (mm) Dimensions US and US 251 (mm) JP44759 25616-04 24026-02 Dimensions with GR 40 (mm) Dimensions with GR 50 (mm) 44759 25643-11 25619-10 3

ACCESSORIES 1 Swing-type check valve Ball check valve Elbow ball check valve Duplex swing-type check valve for duplex pump stations, H W D Code No. 62 62 62 62 102 E ES D DS E 1½ (DN 40), PN 4 150 120 1½ JP00317 2 (DN 50), PN 4 150 120 2 JP00326 2 (DN 50), PN 6 185 155 2 JP44782 1½ (DN 40), PN 6, 170 125 1½ 1½ (DN 40), PN 4 200 280 1½ JP44783 JP09155 2 Stop valve 1½ (DN 40), PN 16 H W D 125 max.60 1½ JP44786 2 (DN 50), PN 16 140 max. 672 JP44787 3 Elastic connection 1½ (DN 40), PN 4 H D 120 50 JP44777 2 (DN 50), PN 4 150 63 JP44775 4 Hose band clamp 1½ JP44763 2 JP44764 5 Elbow 1½ JP45953 Elbow 2 JP44771 6 Alarm unit AG3 with submersible ball contact switch, separate, JP44891 mains-dependent, with potential-free contact and 3 m cable Alarm unit AG10 ditto, with 9.5 m cable JP44892 Alarm unit washing machine stop AW3 with submersible ball contact switch with 3 m cable, separate, mains-dependent JP44895 ND 1 BD B 7 Separate level controls for single unit (see level controls for description) NE 1 (Single-phase current) with sub. ball contact switch 3.0 m JP16710 NE 2 (Single-phase current) with sub. ball contact switch 9.5 m JP16711 ND 1 (3-phase current) with sub. ball contact switch 3.0 m JP16712 ND 3 (3-phase current) with sub. ball contact switch 9.5 m JP16713 NE 1A (Single-phase current) with sub. ball contact switch 3.0 m and alarm system JP16714 NE 2A (Single-phase current) with sub. ball contact switch 9.5 m and alarm system JP16715 ND 1A (3-phase current) with sub. ball contact switch 3.0 m and alarm system JP16716 ND 3A (3-phase current) with sub. ball contact switch 9.5 m and alarm system JP16717 Counterweight (1 piece) JP44803 Duplex control units (see section on level controls for description) BD 00 E (Single-phase current) JP45735 BD 610 EC (Single-phase current with operating capacitor) JP45743 BD 00 (3-phase current) JP45993 BD 25 (3-phase current) JP45737 BD 46 (3-phase current) JP45739 Subm. switch pack B with 3 subm. ball contact switches with 9.5 m cable and fixing device JP16725 BmG with 3 subm. ball contact switches with 9,5 m cable and counterweight JP16726 Protective motor safety plug 230 V (without level control) JP40264 Protective motor plug 8 A, 230 V (without level control) JP44753 Protective motor plug 2.5 4 A, 400 V (without level control) JP44754 CEE-Protective motor plug 400 V (without level control) 2,8 4,0 A JP44750 4,0 6,0 A JP44751 8 Rechargeable battery for off the line operation of the alarm system JP44850 9 Seal leak detector DKG JP44900 10 Special float assembly for low switching points Switching points US 62 ON/OFF US 102 ON/OFF US 152 ON/OFF without GR 155/105 mm 185/135 mm 210/160 mm with GR 180/130 mm 210/160 mm 235/185 mm JP44795 11 Chain certified, stainless steel, 2.5 m, 5 rings,160 kg, (EN818 mod.) JP45901 12 Webbing with Shackle A 0.6 JP45168 13 Guide rail system GR 40 JP25592 Guide rail system GR 50 JP25593 ** only for single units in connection with a motor protection plug Control unit on request 4

102 102 102 152 152 152 152 ES D DS E ES D DS E ES D DS 251 D 251 DS Example of single pump installation with GR US 62+102+152 sump area with GR 40 min. 40 x 60 cm US 62+102+152 sump area without GR min. 40 x 40 cm (without illustration) US +251 sump area with GR 50 min. 40 x 70 cm (without illustration) US -251 sump area without GR min. 40 x 50 cm (without illustration) Suspend control unit in a dry room. 25893-06 In case of installation beneath the backpressure level the pressure tube must be taken in a loop over the local backup level acc. to EN 12056. Besides, it must be secured with an EN 12050-4-proofed swing-type check valve. Additionally we recommend an alarm system. Example of duplex pump installation US 62+102+152 sump area without GR min. 40 x 60 cm US 62+102+152 sump area with GR 40 min. 60 x 60 cm (without llustration) US +251 sump area without GR min. 50 x 70 cm (without llustration) US +251 sump area with GR 50 min. 70 x 70 cm (without illustration) Peak load ON ALARM Basic load ON OFF Notice of min. distance! 25633-03 In accordance with DIN EN 12056-4 section 5.1, it has a built-in automatic spare pump or a double attachment included, which ensures that sewage drainage is not interrupted. 5

TECHNICAL DATA Pump Vertical, single-stage, submersible, open centrifugal impeller with 10 mm free passage US 62, US 102 and US 152: volute casing with discharge branch 1½" (female thread). US and US 251: spiral casing with horizontal discharge 2 (female thread). Bearings Common shaft for pump and motor, with ball bearings, deep groove ball bearing with grease chamber (US and 251 with angular ball bearings). Seal Silicon carbide mechanical seal, oil chamber and duplex rotary seal towards the motor section, safe to run dry, a seal leak control can be connected. Motor Submersible, motor type of enclosure IP 68, insulation class B or F (US and US 251), winding thermostat protects the motor from overload, starting via plug, automatically via mounted circuit or submersible ball contact switches. US 152: To protect the motor, a correct adjusted motor protecting switch has to be provided in the control unit at site by the customer. US E: To protect the motor, a correct adjusted motor protecting switch and an operating capacitor 30 µf have to be provided in the control unit at site by the customer.the winding thermostat (provided by customer in the control unit) must be corrected in series with the input side of the motor contactor. US D und US 251 D: To protect the motor, a correct adjusted motor protection switch has to be provided in the control unit at site by the customer. The winding thermostat (provided by customer in the control unit) must be corrected in series with the input side of the motor contactor. Materials: Volute casing or spiral housing made off GG grey cast iron, power supply through rubber insulated flexible cable. US 62, US 102 and US 152: Terminal board lid, open centrifugal impeller, wear plate and foot strainer made off GRP, motor casing and shaft from stainless steel. US and US 251: Motor casing and cable inlet made of GG grey cast iron, open centrifugal impeller and foot strainer made of GRP, rubber coated wear plate, shaft from C 45 steel encapsulated Installation Pump can be installed free standing or in connection with guide rail system GR 40 or GR 50. Scope of supply Pump according to DIN EN 12050 ready for connection with 10 m cable. US 62 and US 102 with safety plug (1-phase) or CEE-Plug (3-phase). US, US 152 and 251: Pumps without level control with free lead end. Pump with built-in level control with CEE-Plug and phase inverter (3-phase) or safetyplug (1-phase). 6 PUMP TECHNICAL SERVICES LTD. Pump House Unit 12 Bilton Road Industrial Estate Erith Kent DA8 2AN Phone 01322 357080 Fax 01322 341341 sales@pts-jung.co.uk www.pts-jung.co.uk Jung Pumpen GmbH 33803 Steinhagen Germany Phone +49 5204 17-0 Fax +49 5204 80368 info@jung-pumpen.de www.jung-pumpen.de