SUBMERSIBLE PUMP HSE RANGE

Similar documents
SUBMERSIBLE PUMP HSE RANGE

SUBMERSIBLE PUMPS HSE RANGE OPERATING & MAINTENANCE INSTRUCTIONS GC0514

SUBMERSIBLE WATER PUMPS

SUBMERSIBLE WATER PUMP OPERATING & MAINTENANCE INSTRUCTIONS. Model Nos. CSE400A. Part No iss 2

SUBMERSIBLE PUMP. Model No: HIPPO 2 OPERATING & MAINTENANCE INSTRUCTIONS

SUBMERSIBLE WATER PUMP

SUBMERSIBLE WATER PUMP

SUBMERSIBLE WATER PUMP

OPERATION & MAINTENANCE INSTRUCTIONS

SUBMERSIBLE DIRTY WATER PUMP

OPERATION & MAINTENANCE INSTRUCTIONS

250W PUDDLE PUMP WITH AUTO SENSOR MODEL NO: PSP105

POND PUMP Model Nos:SPP3 & SPP6 0200

28W WORK LAMP Model: CTL28 Part No:

Bore Hole Pump Model Nos: CBB75 CBB100 Part Nos:

Matala. VersiFlow Series. Instruction and Maintenance Manual

ELECTRIC HOIST MODEL NO: CH2500B, CH4000B OPERATION & MAINTENANCE INSTRUCTIONS PART NO: , LS1010

ESE Series Cast Iron Sewage Pumps

PHASE CONVERTERS OPERATING & MAINTENANCE INSTRUCTIONS. MODEL NO: PC40 and PC60. PART Nos:

GeyserMax-Flow Series

1 ELECTRIC WATER PUMP

Owner s Manual Drill and Light Weight Portable Utility Pumps

CP series. Submersible utility pump 50HZ STAIRS INDUSTRIAL CO., LTD.

AIR FILTER MODEL NO: AF1000 OPERATION & MAINTENANCE INSTRUCTIONS PART NO:

SWIMMING POOL PUMPS Models SPP07, SPP10 & SPP15 Part Nos: , &

OPERATING & MAINTENANCE INSTRUCTIONS

LEAD ACID BATTERY CHARGER

BENCH GRINDER MODEL CBG6RZ OPERATING & MAINTENANCE INSTRUCTIONS

BENCH GRINDER MODEL CBG6RP OPERATING & MAINTENANCE INSTRUCTIONS 0101

230V DIESEL FUEL TRANSFER PUMP MODEL NO: DFT230

SUBMERSIBLE SUMP PUMPS

BATTERY/BOOSTER CHARGER. Model No: BC100N Part No: OPERATING & MAINTENANCE INSTRUCTIONS

HEAVY DUTY BATTERY BOOSTERS / CHARGERS. MODEL Nos. BC185N & BC205N OPERATING INSTRUCTIONS

OPERATING & MAINTENANCE INSTRUCTIONS

ELECTRIC HOIST MODEL NO: CH2500B, CH4000B OPERATION & MAINTENANCE INSTRUCTIONS PART NO: ,

SUBMERSIBLE SUMP PUMPS

StormPro BA Series Sump Pump

1100W PORTABLE GENERATOR

PEDESTAL SUMP PUMP. MODEL # Español p. 11. Zoeller is a registered trademark of Zoeller Co. All Rights Reserved.

S33 Sump Pump INSTRUCTIONS AND SERVICE MANUAL VERTICAL FLOAT SWITCH S33V1 & S33V1C AUTOMATIC S33P1 & S33PC-1 (CONTROL WITH SERIES PLUG) NOT SHOWN

HOT AIR GUN MODEL No. CHG 1500B Part No

CFT24 &CFT230 PART NOS:

1200W INVERTER GENERATOR

BOOSTER PUMPS Models Nos: BPT600 & BPT1200SS Part Nos: &

Installation & Operating Manual

W/D/V-A1. Submersible Sump Pump. Pump Installation and Service Manual W-A1 V-A1 D-A1

SUNC1200 / ITEM #40882 SUBMERSIBLE UTILITY PUMP OPERATIONS MANUAL

SEWAGE PUMP MODEL # Zoeller is a registered trademark of Zoeller Co. All Rights Reserved. Español p. 14

KING 130 HOT WASHER Part No Product Serial No:...

HOT WASHER MODEL NO: KING 125 OPERATION & MAINTENANCE INSTRUCTIONS PART NO: LS1009

PROFESSIONAL CORDLESS IMPACT SCREWDRIVER

HALOGEN FLOODLIGHTS Models CHL1260C & 1260T Part Nos: &

SWING ARM MAGNIFYING LAMP MODEL NO: SAM170

MODEL Nos: CVAC20SS CVAC25SS CVAC30SSR OPERATING & MAINTENANCE INSTRUCTIONS. Distributed by CLARKE International Ltd.

HEAVY DUTY BATTERY BOOSTERS / CHARGER MODEL No. BC420N

MODEL MRG20 GRINDER PUMP INSTALLATION AND SERVICE MANUAL. 2 HP Grinder Pump for Residential Applications.

PRE-PLUMBED SEWAGE SYSTEM

GRINDER PUMP MODEL # Zoeller is a registered trademark of Zoeller Co. All Rights Reserved. Español p. 13

L-SERIES PUMPS. Operating Manual. Includes Pumps: L-305 L PONDS

StormPro BCV400 Sewage Ejector Pump

ORIGINAL INSTRUCTIONS

INSTALLATION & OPERATION MANUAL

Installation, Operation and Maintenance Manual Stancor SSD & SL Series Pumps

EBARA Fluid Handling

OWNER S MANUAL SELF-PRIMING PORTABLE UTILITY PUMP

BATTERY STARTER/CHARGER MODEL NO: BC125, BC190

OWNER S MANUAL SUBMERSIBLE UTILITY PUMP

BATTERY BOOSTER/CHARGER MODEL NO: DIGICAR 600

Submersible Effluent Pump

barmesapumps.com BP33 & BP & RPM Installation, Operation & Maintenance Manual Submersible Sump / Utility Pumps

SuperFlo 9,000 High Volume Pump Product Manual

BATTERY BOOSTERS / CHARGERS BC120N BC130N BC210N BC320E BC410E BC520N

OIL DRAINER MODEL No: COD70. Part No: ASSEMBLY and OPERATING INSTRUCTIONS 0707

MONZA OIL FREE AIR COMPRESSOR OPERATION & MAINTENANCE INSTRUCTIONS

BATTERY BOOSTER/CHARGER MODEL NO: DIGICAR 900

Model: PFUPPP M10. 1/4 HP 3450 RPM 60 Hz Submersible Utility Pump OWNER S MANUAL. Power-Flo Pumps & Systems PUMPS

MODELS 108 and 138 CRAWL SPACE PUMPING SYSTEM PREINSTALLATION CHECKLIST

SUNC3000 / Item #40885

Operating Manual Includes Pumps: PG-9000 Part #R809606

Installation Manual. Omnivore Grinder Pump Retrofit Unit LSG202-RE. LSGX202-RE 2Hp, V, 1 phase, Automatic LSG202-REX

GENERATOR MODEL NO: FG3000 OPERATION & MAINTENANCE INSTRUCTIONS PART NO: LS0609

Professional Séries. Professional Séries. Model T03828 SUBMERSIBLE SUMP DUPLEX SYSTEM SUBMERSIBLE SUMP DUPLEX SYSTEM. 1/3HP 2400 GPH Head of 20 (6 m)

24V DC - 1/2 SQUARE DRIVE IMPACT WRENCH KIT

DRAIN PUMP SYSTEM MODEL 105 (Korean) INSTALLATION INSTRUCTIONS PREINSTALLATION CHECKLIST

HEAVY DUTY BATTERY BOOSTERS / CHARGERS. MODEL Nos. BC260N & BC335 OPERATING & MAINTENANCE INSTRUCTIONS

DRAIN PUMP SYSTEMS MODELS 104*, 105, 110, 115, 120, 131

12 amp RMS Battery Charger

GENERATOR MODEL NO: FG2500 OPERATION & MAINTENANCE INSTRUCTIONS PART NO: LS0114

AUTOMATIC SUBMERSIBLE UTILITY PUMP

Wilo SP Series Submersible Utility Pumps ETT. ETT Installation and operating instructions

WARNING: Read these instructions before using the machine GENERATOR MODEL NO: IG3500F PART NO: OPERATION & MAINTENANCE INSTRUCTIONS

USER S MANUAL FOR F & Q. Submersible Sewage Pumps

Unilift KP 150, KP 250, KP 350

GARDEN HOSE UTILITY PUMP

Ion Technologies WC33 Submersible Sump Pump

Please contact your supplier (supplying dealer or contractor) if service is necessary or if you have any questions or need further assistance.

Series: PFSWCPC75. 3/4 HP 1750 RPM 60 Hz Submersible Sewage Pump OWNER S MANUAL. Power-Flo Pumps & Systems PUMPS

Sump Pump. Installation and Operating Instructions

5 IN 1 JUMP START OPERATION & MAINTENANCE INSTRUCTIONS MODEL NO: JS5IN1 PART NO: LS0810

CORDLESS COMPRESSOR WITH SPOTLIGHT + JUMP START

Transcription:

SUBMERSIBLE PUMP HSE RANGE OPERATION & MAINTENANCE INSTRUCTIONS 0806

SPECIFICATIONS Model No. HSE120* HSE200 HSE300*/ HSE360*/ HSEC400* HSE301 HSE361 Outlet Dia. (mm/inches) 32/1-1/4 38/1-1/2 50/2 50/2 50/2 Motor Voltage 230V 50Hz 230V 50Hz 230V 50Hz 230V 50Hz 230V 50Hz 115V 50Hz 115V 50Hz Motor Wattage (W) 320 420 720 960 720 720 960 Max. Head (M) 7 10 10 10 8 Max. Flow Rate (L/min) 160 200 300 360 240 Max. Solids Diameter(mm) 5 25 30 30 10 Dimensions LxWxH (mm) 180x130x210 197x135x314 225x141x350 225x141x365 230x170x240 230x141x350 230x141x365 Cable (Max. mm 2 ) 10x1.00 10x1.00 10x1.00 10x1.00 10x1.00 * Includes the automatic (A) version 2

Please read these instructions carefully before operating the tool Thank you for purchasing this CLARKE Submersible Pump. These pumps are ideal for draining ponds, pools and building excavations, these heavy duty pumps can handle small solids in suspension. Before using the device, please read this manual thoroughly and carefully follow all instructions given. This is for your own safety and that of others around you, and is also to help you achieve long and trouble free service from your new tool. CLARKE GUARANTEE This CLARKE product is guaranteed against faulty manufacture for a period of 12 months from the date of purchase. Please keep your receipt as proof of purchase. This guarantee is invalid if the product is found to have been abused or tampered with in any way, or not used for the purpose for which it was intended. Faulty goods should be returned to their place of purchase, no product can be returned to us without prior permission. This guarantee does not affect your statutory rights. PARTS & SERVICE TEL: 020 8988 7400 or e-mail as follows: PARTS: Parts@clarkeinternational.com SERVICE: Service@clarkeinternational.com Please note that the details and specifications contained herein are correct at the time of going to print. However CLARKE International reserve the right to change specifications at any time without prior notice. Always consult the machines data plate 3

SAFETY PRECAUTIONS WARNING: As with all machinery, there are certain hazards involved with their operation and use. Exercising respect and caution will considerably lessen the risk of personal injury. However, if normal safety precautions are overlooked or ignored, personal injury to the operator even damage to the pump or property, may result. For your own safety and that of others around you, please read these safety instructions in conjunction with the operating instructions, and before using the pump. These pumps are designed to pump Water Only. NEVER use for pumping flammable liquids or chemicals of any kind. An approved Residual Current Device (RCD) MUST be used when pumping from ponds or swimming pools. Your submersible pump may ONLY be used for pumping water from a swimming pool when there is no person or animal in the pool. If the water is likely to freeze, the pump MUST be run continuously, otherwise the pump must be removed from the water and stored in a frost free location. If the pump is to be used where there may be silt or mud etc (e.g., garden ponds), keep the pump clear of any sediment by standing it on a platform or brick or suspending from a rope attached to the handle. NEVER run the pump dry. NEVER run the pump with the body exposed for longer than 10 minutes. NEVER install the pump on sand, silt, mud or ground that is likely to shift. NEVER Lift the pump by the mains cable, or the float switch cable. ALWAYS use the handle, with rope or chain attached when lifting the pump. ALWAYS disconnect the pump from the electrical supply before placing it into, or removing from the water,and before any cleaning or maintenance of the pump. 4

ELECTRICAL CONNECTIONS All models EXCEPT HSE301 & 361, should have their mains lead connected to a standard 230Volt (50Hz) electrical supply through an approved plug or a suitably fused isolator switch. We recommend that these pumps be fitted with a Residual Current Device (RCD). NOTE: This is mandatory when pump is used for pumping swimming pools. Model s HSE301 & 361 must be connected to a protected 110V supply, through a suitably approved connector. On no account must a 230V, 13amp plug be used. NOTE: If a portable 110V transformer is used, make sure it has a rated capacity sufficient to take the load of the pump. In the event that the pump is hard wired into the electrical system, it must be carried out in accordance with IEE regulations. If used for draining swimming pools or ponds, the pump MUST be fitted with a Residual Current Device (RCD), with a rated residual operating current of no greater than 30mA. WARNING: THIS APPLIANCE MUST BE EARTHED IMPORTANT: The wires in the mains lead are coloured in accordance with the following code: Green & Yellow - Earth Blue - Neutral Brown - Live As the colours of the flexible cord of this appliance may not correspond with the coloured markings identifying terminals in your plug proceed as follows: Connect GREEN & YELLOW coloured cord to plug terminal marked with a letter E or Earth symbol or coloured GREEN or GREEN & YELLOW. Connect BROWN cord to terminal marked with a letter L or coloured RED Connect BLUE cord to terminal marked with a letter N or coloured BLACK The fuse in the plug for this appliance must be rated at 13 amps. If this appliance is fitted with a plug which is moulded onto the electric cable (i.e. non-rewirable) please note: 1. The plug must be thrown away if it is cut from the electric cable. There is a danger ofelectric shock if it is subsequently inserted into a socket outlet. 2. Never use the plug without the fuse cover fitted. 3. Replacement fuse covers can be obtained from your local dealer or most electrical outlets 4. The fuse in the plug must be replaced with one of the same rating (13 amps) and this replacement must be ASTA approved to BS1362. IMPORTANT: If in doubt, consult a qualified electrician 5

FEATURES The pumps are of rugged and durable construction, designed for long lasting continuous operation, and the motor is provided with a built in overload protector. These pumps may be used for pumping water, or water containing small solids in suspension, please refer the Specifications on page 2 to determine the solid sizes that may be pumped with your pump. The HSEC 400A is fitted with a Tungsten Carbide cutter, and is specially suited for heavily polluted waste water and waste solids, such as sewage, light slurry, factory waste etc. Automatic Pumps, i.e. those fitted with a Float Switch, denoted by an A suffix to their model number, are suitable for permanent or semi-permanent installations, eg. installations where it is necessary to maintain a water at a particular level. As the water level rises, the switch will float, and start the pump. As the water level falls, so will the float switch, until it stops the pump. Float switches are factory set to provide the correct ON-OFF switching mode. It is not recommended that these pumps be used for pumping drinking water, as there is a remote possibility of water contamination due to leakage of pump lubricant, should the pump malfunction. INSTALLATION The pumps are completely submersible, and should be placed in a vertical position, on a solid flat surface. If this is not available, sit the pump on timber, or house bricks, but ensure they are not likely to shift. Automatic versions should be placed in a sump which has adequate dimensions so as not to restrict the movement of the float switch. Connect the outlet to the largest diameter hose possible, any restrictions will reduce capacity, and put additional strain on the motor. Take all necessary precautionsas described on page 4 before plugging in, and switching ON. SUITABLE HOSE, FOR ALL PUMPS, IS AVAILABLE FROM YOUR CLARKE DEALER 6

TROUBLESHOOTING PROBLEMS Pump does not run and hums POSSIBLE CAUSES * Line circuit breaker is off, or fuse is burned or loosed. * Water level in sump has not reached turn-on level as indicated in installation drawing. * Pump cord is not making contact in receptacle. * Float is stuck. It should operate freely in basin. * If all of the above are OK, and then the motor could be operate. Pump runs but does not deliver water. * Check valve is installed backwards. Arrow on valve should point in direction of flow. * Discharge shut-off valve (if used) may be closed. * Impeller or volute openings are fully or partially clogged. Remove pump and clean. * Pump is air-locked. Start and stop several times by plugging and unplugging cord. Check for clogged vent hole in pump case. * Inlet holes in pump base are clogged. Remove pump and clean the openings. * Vertical pumping distance is too high. Reduce distance or change the discharge fittings of the pump. Pump runs and pumps out sump, but does not stop. Pump runs but delivers only a small amount of water. * Float is stuck in up position. Be sure float operates freely in basin. * Defective float switch. Replace with float switch. * Defective vertical switch. Replace with vertical switch. * Pump is air-locked. Start and stop several times by plugging and unplugging cord. Check for clogged vent hole in pump case. * Vertical pumping distance is too high. Reduce distance or change the discharge fitting of the pump. Inlet holes in pump base are clogged. Remove pump and clean the strainer and openings. * Impeller or volute openings are fully or partially clogged. Remove pump and clean. * Pump impeller is partially clogged with tar or paint, causing motor to run slow and overload. Remove pump and clean. * Pump impeller is partially clogged with tar or paint, causing motor to run slow and overload. Remove pump and clean. Fuse blows or circuit breaker trips when pump starts. * Motor stator may be defective. * Fuse size or circuit breaker may be too small. (Must be 15 amps). * Impeller or volute opening are fully or partially clogged. 7

MAINTENANCE Check pump installation regularly to ensure the base inlet is clear of leaves or other debris. Note that these pumps are fitted with automatic thermal overload protection. If the pump overheats due to an obstruction in the pump, or pumping warm water for example, it will shut off automatically. Switch the pump OFF and disconnect from the mains supply. Check for blockages and allow the motor to cool (at least 5 minutes) before attempting to re-start. This pump should require no maintenance other than regular cleaning. If the pump starts to show signs of wear or damage, contact your CLARKE dealer for advice. Do not use the pump if there is any damage to the mains supply cable, or to the float switch or its cable. Do not attempt to repair the pump yourself, as you may damage the waterproof seal and invalidate your guarantee. Repairs must be carried out by your CLARKE dealer, or contact the CLARKE Service Dep t, on 020 8988 7400 If using this pump to pump out a garden pond, please note that there is a small quantity of oil in the pump seal. If the pump or seal is damaged, possibly caused by running the pump dry, oil may leak out, and appear as a film on the surface of the water. Although harmless to people, the oil must be cleared to prevent any possible harm to pond life. Disconnect the pump from the electrical supply, remove it from the pond, and clear the oil, then contact your CLARKE dealer for advice. 8

PARTS LIST & DIAGRAM HSE 120 No. Description Part No. 1 Strainer HG12001 2 Centrifugal Switch HG12002 3 Pump Housing HG12003 4 Impeller HG12004 5 Lip Seal HG12005 6 Mechanical Seal HG12006 7 Oil Chamber HG12007 8 Bottom Motor Plate HG12008 9 Lower Bearing HG12009 10 O Ring HG12010 11 Rotor Shaft HG12011 12 Stator HG12012 13 Motor Case HG12013 14 Overload Protector HG12014 15 O Ring HG12015 16 Upper Bearing HG12016 17 Capacitor HG12017 18 Upper Cover HG12018 19 Handle HG12019 20 Gland Cover HG12020 21 Cable Gland HG12021 22 Power Cable HG12022 23 Discharge Outlet HG12023 9

PARTS LIST & DIAGRAM HSE 200-300 - 360 HSE200 HSE300 HSE301 HSE360 HSE361 1 Top Cover HG20001 HG30001 HG30101 HG36001 HG36101 2 Upper Bearing HG20002 HG30002 HG30102 HG36002 HG36102 3 Motor Housing HG20003 HG30003 HG30103 HG36003 HG36103 4 Shaft HG20004 HG30004 HG30104 HG36004 HG36104 5 Stator HG20005 HG30005 HG30105 HG36005 HG36105 6 Lower Bearing HG20006 HG30006 HG30106 HG36006 HG36161 7 Seal Platc HG20007 HG30007 HG30107 HG36007 HG36171 8 Oil Seal HG20008 HG30008 HG30108 HG36008 HG36181 9 Me. Seal HG20009 HG30009 HG30109 HG36009 HG36191 10 Seal Cover HG20010 HG30010 HG30110 HG36010 HG36101 11 Impeller HG20011 HG30011 HG30111 HG36011 HG36111 12 Pump Casing HG20012 HG30012 HG30112 HG36012 HG36112 13 Strainer HG20012 HG30013 HG30113 HG36013 HG36113 14 Power cord set HG20014 HG30014 HG30114 HG36014 HG36114 15 Capacitor HG20015 HG30015 HG30115 HG36015 HG36115 10

PARTS LIST & DIAGRAM HSEC 400A No. Description Part No. 1 Strainer HG400A01 2 Strainer Packing HG400A02 3 Impeller HG400A13 4 Pump Casing HG400A04 5 Oil Seal HG400A05 6 Oil Cover HG400A06 7 Oil Cover Packing HG400A07 8 Mechanical Seal HG400A08 9 Motor Casing Pkg HG400A09 10 Lower Bearing HG400A10 11 Motor Casing HG400A11 12 Rotor Shaft HG400A12 13 Stator Coil HG400A13 14 Centrifugal Switch HG400A14 15 Thermal Overload HG400A15 16 Centrifugal Plate HG400A16 17 Upper Bearing HG400A17 18 Motor Casing Pkg HG400A18 19 Inside Cover HG400A19 20 Head Cover Pkg. HG400A20 21 Capacitor HG400A21 22 Cable Gland HG400A22 23 Gland Packing HG400A23 24 Power Cable HG400A24 25 Handle HG400A25 26 Outlet Discharge. HG400A26 11