Type of actuation 4 Piping 0 Side ported Bottom ported 4 Without sub-plate Large Size 5 Port Solenoid Valve Rubber Seal Series 50/4 70 Series VP 5 port solenoid valve 5 7 position single position double position closed center position exhaust center Note) There is no position type for Series 70. Body style 5 4 Standard 4 Standard How to Order 0 0 Port size Symbol Port size Applicable valve model 54 00 Without sub-plate 74 0 8 (0A) 04 (5A) 06 4 (0A) 50 0 (5A) 4 (A) 4 (40A) 70 Only for the side ported type. T G T D TL Nil F N T Rated voltage 00 VAC, 50/60 Hz 00 VAC, 50/60 Hz 0 VAC, 50/60 Hz 4 0 VAC, 50/60 Hz 5 4 VDC 6 VDC 7 40 VAC, 50/60 Hz 9 Other Thread type Rc G NPT NPTF Electrical entry Grommet Conduit terminal DIN terminal Conduit terminal with indicator light DL DIN terminal with indicator light How to Order Pilot Valve Assembly Made to Order specifications Refer to page 87. Nil Standard X With surge voltage suppressor X40 External pilot J 4 5 C C4 Z S R 7 VT 00 G Rated voltage 00 VAC, 50/60 Hz 00 VAC, 50/60 Hz 0 VAC, 50/60 Hz 4 0 VAC, 50/60 Hz 5 4 VDC 6 VDC 7 40 VAC, 50/60 Hz 9 Other Electrical entry Note) G Grommet Note) Even if the electrical entry of the solenoid valve is T, D, TL, or DL, the electrical entry for pilot valve assembly is chosen for G. 86
Series 50/4 70 Symbol 50/470 (B) (A) 4 (EB)(P) 5 (EA) 50 (B) (A) 4 50/470 (B) (A) 4 (EB)(P) 5 (EA) Specifications Fluid Operating pressure range (MPa) Ambient and fluid temperature ( C) Max. operating frequency (Hz) Lubrication () Manual override Mounting orientation Impact/Vibration resistance (m/s () ) Accessory (Standard equipment) Air 0. to 0.9 0 to 60 (No freezing. Refer to page 5.) Required (Turbine oil Class ISO VG) Yes (Non-locking) Unrestricted 50/50 Silencer for pilot EXH ( AN0-0 ) Note ) This solenoid valve requires lubrication. Use turbine oil Class (ISO VG). Note ) Impact resistance: No malfunction occurred when it is tested with a drop tester in the axial direction and at the right angles to the main valve and armature in both energized and de-energized states every once for each condition. (Values at the initial period) Vibration resistance: No malfunction occurred in a one-sweep test between 45 and 000 Hz. Test was performed at both energized and de-energized states in the axial direction and at the right angles to the main valve and armature. (Values at the initial period) Solenoid Specifications Electrical entry Standard Option AC (50/60 Hz) Coil rated voltage (V) DC Allowable voltage fluctuation Note) Inrush Apparent power (VA) AC Holding Power consumption (W) Note) DC Note) At rated voltage Grommet (G) Conduit terminal (T) DIN terminal (D) Conduit terminal with indicator light (TL) DIN terminal with indicator light (DL) 00, 00, 0, 0, 40, 4 5 to +0% of rated voltage 7 (50 Hz), 58 (60 Hz) 8 (50 Hz), 7 (60 Hz) (EB)(P) 5 (EA) 450 50 50 50 450 (B) 50 70 50 70 50 450 (A) 4 (EB)(P) 5 (EA) Flow Characteristics/Weight position position position position 864 Made to Order Specifications (For details, refer to page 87.) Type of actuation Single Double Closed center Exhaust center Type of actuation Single Double Closed center Exhaust center Model Model Port size 8 4 8 4 8 4 8 4 Port size 4 4 5 7 5 7 6 8 6 8 Effective area (mm ) 0 80 00 0 80 00 0 0 Response Time Note) Model 50 70 50 70 50 450 ON 0 or less 40 or less 0 or less 0 or less 0 or less 0 or less Response time (ms) AC OFF 50 or less 65 or less 0 or less 0 or less 0 or less 0 or less (at the pressure ON 40 or less 55 or less 40 or less 45 or less 40 or less 40 or less of 0.5 MPa) DC OFF 40 or less 55 or less 40 or less 45 or less 0 or less 0 or less Note) Based on dynamic performance test, JIS B 875-98. (Coil temperature: 0 C, at rated voltage, without surge voltage suppressor.) Weight (kg). 9.5.8 0 4.4 4.4 b Cv b Cv 0. 0.5 0. 0. 0.5 0. 0.8 0.7 0.9 0.8 0.4 0.5 Flow characteristics.6 4.0 5..6 4.0 5. 4.0 4.7 5..9 4.5 5. 6 9 6 9 5 8 0 6(5) 9(6) (8) Weight (kg) 0. 4.5.5 0.8 5. 0.8 5.6. 0. 4.5.0 0.8 5. 0.8 5.6.8 0.9 4.0.6 0. 4.5 0. 5.0 4.4 0.9(0.8) 4.(4.0).6 0.4(0.7) 4.8(4.5) 0.(0.0) 5.5(4.8) 4.4 ( ): Denotes the normal position.
Rubber Seal Large Size 5 Port Solenoid Valve Series 50/4 70 Construction (B) (A) 4 (B) (A) 4 position single position double Closed center (B) (A) 4 5 (EB)(P)(EA) Exhaust center Component Parts No. 4 5 6 7 8 9 5 (EB)(P)(EA) (B) (A) 4 5 (EB)(P)(EA) Description Body Plate Cap Spacer Spool Sleeve Piston Center sleeve Side poppet Material Aluminum alloy Aluminum alloy Aluminum alloy Aluminum alloy Stainless steel/aluminum alloy position: Aluminum alloy position: Brass position: Resin position: Stainless steel Resin Brass, NBR Replacement Parts No. Description Part no. 0 Sub-plate AXT0--- AXT0--- DXT-5P-06 DXT-5P-0 DXT-5-P- DXT-5-P-4 XT0-9 Gasket DXT-6 Hexagon socket M6 x 5 with washer head screw M8 x 5 Pilot valve assembly VT-00 G Silencer (AN0-0) position closed center/exhaust center Note Platinum silver Platinum silver Platinum silver Platinum silver 5 (EB)(P)(EA) Silencer (AN0-0) Note 8 50 4 Aluminum alloy 4 70 in part numbers are the same symbol for the thread type in How to Order. 50 70 50 Thread for mounting valve. A spring washer 70 will be required separately for 70. Refer to How to Order Pilot Valve Assembly on page 86. Silencer (AN0-0) 865 J 4 5 C C4 Z S R 7
Series 50/4 70 Dimensions: 50 Grommet: 50- G- Bottom ported 40 (9) 0 (68) 4 x ø9 mounting hole (ø) Manual override 5 x 8, ( 4 ) 5 x 8, ( 4, ) ( ): Rc /4, Conduit terminal: 50- T- DIN terminal: 50- D- Applicable cable O.D. ø6 to ø Max. 8 (6) 47 (7) 60 (84) 6 (4) 86 (00) 5 (76) 84 (00) 04 (4) ( ): Rc /4, ( ): Rc /4, 866
Rubber Seal Large Size 5 Port Solenoid Valve Series 50/4 70 Dimensions: 50/450/4450 Grommet: 50- G-, 50- G- 450- G- 86 (00) 40 (9) 0 (68) Conduit terminal: 50- T- 50- T- 450- T- 4-ø94 x ø9 mounting hole (ø) 5 x 8, ( 4, ) Manual override Bottom ported DIN terminal: 50- D- 50- D- 450- D- ( ): Rc /4, Applicable cable O.D. ø6 to ø Max. 47 (7) 60 (84) position: 87 position: 0 position: 94 84 (00) 6 (4) 04 (4) 5 (76) 5 x 8, ( 4 ) J 4 5 C C4 Z S R 7 8 (6) ( ): Rc /4, ( ): Rc /4, 867
Series 50/4 70 Dimensions: 70 4 Grommet: 70- G- Bottom ported 4 x ø (Mounting hole) Manual override (5 x 4, ) 5 x 4, 4 Conduit terminal: 70- T- 4 DIN terminal: 70- D- Applicable cable O.D. ø6 to ø Max. 868
Rubber Seal Large Size 5 Port Solenoid Valve Series 50/4 70 Dimensions: 70 Grommet: 70-4 G- Bottom ported 4 x ø (Mounting hole) Manual override Conduit terminal:70-4 T- DIN terminal: 70-4 D- 5 x 4, Applicable cable O.D. ø6 to ø Max. (5 x 4, ) J 4 5 C C4 Z S R 7 869
Series 50 Manifold Specifications How to Order Common EXH Individual EXH V Series VP 5 port solenoid valve Manifold Base size 5 4 6 5 Porting specifications Symbol P A, B E 0 Side Side Side Side Bottom Note) Side 9 Other Note) A/B port piping: /8 or / 0 04 04 Thread type Nil Rc F G N NPT T NPTF A/B Port size Symbol Port size V50 V60 04 06 4 0 M Note) Mixed Note) In the case of Mix, put M in the part number and indicate each port size in other places. Base specifications Valve stations Common EXH 0 stations Individual EXH 0 0 stations Precautions No manifold is available for Series 70. Specifications How to Order Manifold Assembly Specify the valves and blanking plate to be mounted on the manifold along with the manifold base model no. <Example> Base (4 stations), Common EXH, 00 VAC, DIN terminal, A/B port: Rc /4 V60-04-06 pc. 54-00D pcs. 54-00D pc. XT08N-4A pc. The asterisk denotes the symbol for assembly. Prefix it to the part nos. of the solenoid valve, etc. Manifold type B mount Exhaust type Common EXH, Individual EXH () Supply type Common SUP Valve stations Max. 0 stations (V60: Max. 8 stations) () Note ) If throttling exhaust air, use individual exhaust style so that backing pressure does not cause trouble. Note ) In the case of 4 stations or more, supply air pressure from both sides and exhaust from both sides. Simultaneous Operation of Manifold Valves Simultaneous operation of manifold valves can cause pressure drop. Model Series V50 V60 Exhaust Port size specifications P A, B E Common Individual 4, 4 4 Common Individual 4, Applicable valve model 54-00 54-00 54-00 454-00 870 Option Blanking plate assembly XT08N-4A With gaskets and bolts
Series 50 Dimensions: V50/460 Common EXH: V50- Stations - Port size - V60- Stations - Port size - Grommet Conduit terminal DIN terminal 4 x ø Mounting hole 4n x, 4 Piping port 6 x 4 Piping port Individual EXH: V50- Stations - Port size - V60- Stations - Port size - Grommet Conduit terminal DIN terminal 4 x ø Mounting hole x 4 Piping port Applicable cable O.D. ø6 to ø ( ): V60 Applicable cable O.D. ø6 to ø J 4 5 C C4 Z S R 7 ( ): V60 4n x, 4 Piping port (/4, ) n x 4 Piping port () L Dimension Model V50 V60 n: Station 4 5 6 7 8 9 0 Formula Stations L L 57 07 44 94 4 48 58 568 605 655 69 74 779 89 866 96 95 00 L=87 x n+8 L=87 x n+ L 06 44 5 60 78 846 954 L=08 x n+90 L4 56 464 57 680 788 896 004 L4=08 x n+40 L dimension 87
B B Made to Order Specifications: Series 50/4 70 External Pilot/With Surge Voltage Suppressor External Pilot -X40 Model no. ( ) X40 Entry is the same as standard products. Dimensions Same as those of standard models. For the external pilot port position, refer to the below. 50 8 ( position: 98.5) 70 9 A B 7(95.5) 9.5 /8 (External pilot port) A B A B /8 (External pilot port) A B B A EB P EA EB P EA Dimensions: Port size /8, / ( ): Port size /4, With Surge Voltage Suppressor -X Model no. ( ) X Dimensions Same as those of standard models. Entry is the same as standard products. Electrical entry T Conduit terminal D DIN terminal TL Conduit terminal with indicator light DL DIN terminal with indicator light 87
Series 50/4 70 Specific Product Precautions Be sure to read before handling. Refer to front matter 5 for Safety Instructions and pages to 8 for /4/5 Port Solenoid Valve Precautions. Caution. Piping Make P port piping so that supply air pressure does not become lower than operating pressure while operating. If throttling air flow of P port, or opening A/B ports in the atmosphere (or opening in almost the same conditions), pressure drop at operating can cause malfunction of the valve.. Air quality Install an air filter and a lubricator on the upstream side.. Lubrication This solenoid valve requires lubrication. Use turbine oil Class (ISO VG). Besides that, for brands of each manufacturer, refer to SMC website. 4. Operating environment Install silencer in EA/EB/Pilot EXH port to prevent dust from entering in the dusty ambient. 5. Operation at low temperature If operating at 0 C or less, external pilot style solenoid valve is recommended. (Made to order; suffix -X40 to the part number.) 6. Regarding 5 ( position closed center type) Be aware that when the cylinder is in an intermediate stop state, if the supply pressure to the P port is discharged or decreased, this valve is constructed so that the pressure in the cylinder will be discharged to the P port, causing the cylinder to move. 7. How to calculate the flow rate For obtaining the flow rate, refer to front matters 4 to 45. How to Use DIN Terminal. Disassembly ) After loosening the screw (), then if the housing (4) is pulled in the direction of the screw, the connector will be removed from the body of equipment (solenoid, etc.). ) Pull the screw (), and then remove gasket (a) or (b). ) On the bottom part of the terminal block (), there s a cut-off part (indication of an arrow). If a small flat head screwdriver is inserted between the opening in the (a) bottom, terminal block () will be removed from the cover (4). (Refer to figure at right.) 4) Remove the cable gland (5) and plain washer (6) and rubber seal (7).. Wiring ) Pass them through the cable (8) in the order of cable ground (5), washer (6), rubber seal (7), and then insert into the housing (4). ) Dimensions of the cable (8) are the figure as below. Skin the cable and crimp the crimped terminal (9) to the edges. ) Remove the screw with washer (e) from the bracket (e). (Loosen in the case of Y-shape type terminal.) As shown in the below figure, mount a crimped terminal (9), and then again tighten the screw (e). Note) Tighten within the tightening torque of 0.5 N m ± 5%. Note: a It is possible to wire even in the state of bare wire. In that case, loosen the screw with washer (e) and place a lead wire into the bracket, (d) and then tighten it once again. b Maximum size of crimped terminal (9) is up to.5 mm -.5 when O terminal. For Y terminal, it is up to.5 mm -4. c Cable (8) outside diameter: ø 6 to ø mm Note) For the one with the outside diameter ranged between ø 9 to ø mm, remove the inside parts of the rubber seal (7) before using.. Assembly ) Terminal block () connected with housing (4) should be reinstated. ) Putting rubber seal (7), plain washer (6), in this order into the cable introducing slit on the housing (4), then further tighten the cable gland (5) securely. ) By inserting gasket (a) or (b) between the bottom part of the terminal block () and a plug on an equipment, screw in () on top of the housing (4) and tighten it. Note) Tighten within the tightening torque of 0.5 N m ±0%. Changing the entry direction The cable entry direction of a connector can be changed as desired (4 directions at 90 intervals), depending on the combination of a housing (4) and a terminal block (). Exploded view () (4) (d) (d) (c) () (a) (e) (9) (a) (6) (7) (e) (e) Magnifying figure Self-up screw (5) (8) J 4 5 C C4 Z S R 7 (b) DlN Terminal (Connection) Solenoid is wired with male thread terminals of DIN connector as follows. Connect with corresponding terminals of the connector. Terminal Polarity A side B side COM Can be used as either + COM or COM. 87 A