Extended Battery Cabinet for Nfinity

Similar documents
Nfinity Battery Run Time Charts

SOS SERIES SOS1 SOS2. Spares On Site Battery Cabinet Installation Guide rEV3

USER MANUAL English / Español

Start UP Guide. Symmetra LX Tower Rack-Mount. UPS Models 200 V, 4-8 kva 208/240 V, 4-8 kva 220/230/240 V, 4-8 kva

Installation Guide Smart-UPS On-Line SRT1000/SRT1500 XLA Tower/Rack-Mount

AC Power For Business-Critical Continuity. Liebert PSI XR. User Manual 1000/1500/2200/3000VA, 50/60Hz, 230VAC

Safety and General Information

Electrical Installation

Powerware Vdc Extended Battery Cabinet User s Guide.

Galaxy VM. Modular Battery Cabinets Installation GVMMODBCW, GVMMODBCN 09/

Installation Guide Smart-UPS On-Line SRT1000/1500 UXI-NCLI, SRT1000/1500 UXI-LI, Tower/Rack-Mount

Liebert GXT3 230V, ,000VA

POWERWARE User s Guide VA.

AIS and 40 kva 400 V. Site Preparation and Installation Manual

Installation and user manual 5SC 500 5SC 750 5SC SC SC 500G 5SC 750G 5SC 1500G ENGLISH. Copyright 2013 EATON All rights reserved.

Liebert PSI XR 1000/1500/2200/3000, 120VAC. User Manual

Liebert Hipulse E The High-ECO-Availability UPS. AC Power Systems

Liebert PSA VA. Installer/User Guide

Liebert GXT2-6000RTL630

Liebert GXT3 UPS 230V 700VA-3000VA

User Manual Digital Energy Uninterruptible Power Supply ML Series UPS VA GE Digital Energy Power Quality

BRAVER UPS. (Uninterruptible Power System) User s Manual

Industrial On-Line UPS V, 700 VA VA. S4KC Series. Instruction Manual

USER MANUAL. Uninterruptible Power Supply Line-interactive VCL Series UPS VA

Galaxy VM. Battery Breaker Box Installation 09/

DISCONTINUED PRODUCT. AC Power Systems For Business-Critical Continuity. Liebert GXT2U. User Manual - 208V, 2700VA

Liebert GXT4. User Manual 700VA ~ 3000VA (230V)

User Manual. NetGuard IMPORTANT. PSD 650/1200/1600 Line Interactive UPS Uninterruptible Power Supply System. UPS Monitoring Software

RT Series Step Down Transformer for RT Series UPS 6-10kVA UL Input Vac Output Vac User Guide

User Manual. Digital Energy Uninterruptible Power Supply ML Series UPS VA. GE Digital Energy Power Quality. GE imagination at work

Pulsar Evolution 2200/3000/3000 XL

ENVIRONMENTAL PROTECTION. DataCool INSTALLATION, OPERATION &MAINTENANCE. 20 kw Nominal Capacity

Industrial On-Line UPS V, 6000 & VA. S4KC Series. Instruction Manual

Allen-Bradley. User Manual for 8000/10000 VA UPS. Tower/Rack-Mount 6U Uninterruptible Power Supply

SLA Battery Capacity Analyzer

Eaton Battery Charger Module Models ASY-0652 and ASY-0675 User s Guide

Galaxy VM. Classic Battery Cabinet Installation GVMCBCWUE, GVMCBC2WUE, GVMCBC2WUF, GVMCBC3WUF 07/2017.

USER'S GUIDE. WiseHP11 SINGLE PHASE HIGH PRECISION AVR SERVO-MOTOR AUTOMATIC VOLTAGE STABILIZER

Operation and Maintenance

Allen-Bradley. User Manual for 3000/5000 VA UPS. Tower/Rack-Mount 3U Uninterruptible Power Supply

1. INTRODUCTION. Features:

Match 19" GE Digital Energy. Uninterruptible Power Supply VA. Technology for the Digital World. Match 19" UPS.

A419ABG-3C Electronic Temperature Control

Connecting External Battery Cabinet(s) to the UNITY/I 9910-UPS

XPRT 6kVA & 10kVA Online UPS

Liebert FS Flywheel DC Energy Storage System

User Manual Easy UPS BV Series 500VA, 650VA, 800VA, 1000VA Safety and General Information

DIGITAL PHYSICIAN Waist-High Scale Models 8430, 8431 & 8437 Operating Instructions

USER MANUAL. Blazer Vista 1000/1400/2000. Uninterruptible Power System

UPStation GXT. 6 & 10 kva 208V & 240V. USER MANUAL English

1. INTRODUCTION SYSTEM DESCRIPTION Front Panel CONNECTION AND OPERATION TROUBLESHOOTING...8

Liebert PowerSure PSI

PR1000ELCD / PR1500ELCD User s Manual

MOTION-ACTIVATED WALL LANTERN

Galaxy kva 3:3 and 3:1. Receiving and Unpacking. 380/400/415 and 208/220 V 04/2016.

User s Manual Lithium-ion Storage Battery Unit (Home-use, 9.89 kwh)

Uninterruptible Power Systems. SDU DC Series

NB NB 1511 NB NB 4031 TRUE ON-LINE DOUBLE CONVERSION UPS

Eclipse Plus VA UPS and Surge Suppressor User s Manual

Snapshot. Use on Dimmer Outdoor Use Sound-Activated DMX Master/Slave 120 V/230 V Switchable Replaceable Fuse User-Serviceable.

Liebert GXT MT+ User Manual VA Installer/User Guide

Liebert NX8 User Manual +%`K6 UPS

Innovative Circuit Technology Ltd.

SEAUPS-III Uninterruptible Power Conditioning System. System Manual

XPC-EBP64 External Battery Pack User & Installation Manual Xtreme Power Conversion Corporation. All rights reserved.

TOD-BCU-PNUS2. Installation Manual. Connection Box for EIBS16GU2 or EIBS16GU2+ (Storage Battery System) For Installation Company Use

LED/Switch Modules Installation Instructions

Symmetra PX. 48 kw 400 V, 96 kw 400 V, 100 kw 208 V, 160 kw 400 V. Receiving and Unpacking 01/2016.

Installation Power Management Unit Battery Cables and Battery Harness

USER MANUAL. Power GUARD UPS. Uninterruptible Power System

3000VA 120/208/230VAC

Enclosure for AMP1 Series Energy Meters with Swing Panel Kit

Illuminator System Series CM

Battery Unit BHM60PC/BHM100PC Instruction Manual

Warning! General Maintenance 4-11

Dual-Lite Trident TRF 40 Wide Battery Cabinet 20-40kVA Systems USER MANUAL

DC AC POWER INVERTER. LIV 10 / LIV 20 / LIV 30 User Manual

USER MANUAL ONLINE UPS 6000L(XL)/10000L(XL) Uninterruptible Power Supply

Galaxy Receiving and Unpacking 09/

On Line UPS. LUC 1000E / LUC 2000E / LUC 3000E User Manual

APC Smart-UPS RT UXI/UXICH

KeContact P20. User manual

- Wiring Brochure Zone Manager 335

MAKING MODERN LIVING POSSIBLE. UniLynx Indoor Installation Manual. ULX 1800i ULX 3000i ULX 3600i ULX 5400i SOLAR INVERTERS

SDU 24-BATEM. Instruction Manual. Technical Services External Battery. U.S.A... (800) International (847)

Uninterruptible Power Supply

Switching DC Power Supply

A419 Series Electronic Temperature Controls with NEMA 1 or NEMA 4X Watertight Enclosures

nual k Voltage Stabilizer N) manual New Brunswick Voltage Stabilizer Operating manual

OPERATING INSTRUCTIONS

Self-Leveling Rotary Laser Level with GreenBrite Technology Model No Instruction Manual

Snapshot LX5 USER MANUAL. OK on Dimmer Outdoor OK Sound Activated DMX512 Master/Slave 115V/230V Switch Replaceable Fuse User Serviceable Duty Cycle

miconverter 18-Module Rack-Mount Power Chassis User Manual 38 Tesla, Irvine, CA USA Phone: (949) ; Fax: (949) Page 12

02/15/01. Powerware User s Guide VA.

Thank you for choosing EATON products. Safety information and operating instructions are included in this manual. Do not attempt to operate the UPS

HP BladeSystem c7000 Carrier-Grade Options Installation Guide

User Manual V1.1 OptiFlex 1100 / OptiFlex 2000

Installing Power Components

- Wiring Brochure Zone Manager 336

Installation and user manual. Tower models 5P 750 5P P P 850G 5P 1550G

Transcription:

POWER PROTECTION Extended Battery Cabinet for Nfinity USER MANUAL

TABLE OF CONTENTS IMPORTANT SAFETY INSTRUCTIONS................................... 1 ELECTROMAGNETIC COMPATIBILITY....................................... 1 OPERATING ENVIRONMENT............................................. 1 GLOSSARY OF SYMBOLS............................................. 2 GENERAL DESCRIPTION.............................................. 3 SYSTEM DESCRIPTION................................................ 3 FEATURES:......................................................... 3 PREPARATION....................................................... 4 INSPECTION........................................................ 4 ENVIRONMENT...................................................... 4 REQUIRED SETUP EQUIPMENT.......................................... 4 SITE PREPARATION................................................... 4 UNLOADING......................................................... 5 UNLOADING THE EXTENDED BATTERY CABINET.............................. 5 STATIONARY MOUNTING............................................... 6 OPTIONAL STATIONARY MOUNTING....................................... 6 INSTALLATION....................................................... 7 GROUNDING........................................................ 7 COMMUNICATIONS................................................... 7 DC POWER........................................................ 7 CONFIGURATION SETTING.............................................. 8 MODULE REPLACEMENT.............................................. 9 REMOVING MODULES................................................. 9 REPLACING MODULES................................................ 10 BATTERY RUN TIMES................................................ 11 INTERNAL AND EXTENDED BATTERY CABINETS (MINUTES)..................... 11 i

IMPORTANT SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS This manual contains important instructions that should be closely followed during installation of this Extended Battery Cabinet. This product is designed for commercial/industrial use only. This product is not intended for use with life-support and other designated critical devices. WARNING! Lethal voltages may be present within this unit even when it is apparently not operating. Observe all cautions and warnings in this manual. Failure to do so may result in serious injury or death. Never work alone. Observe the following precautions when working with batteries: CAUTION! DO NOT dispose of battery modules in a fire; the battery module may explode. DO NOT open or mutilate batteries; released electrolyte is harmful to skin and eyes and may be toxic. A battery can present a risk of electrical shock and high shortcircuit current. The following precautions should be observed when working on batteries. Remove watches, rings and other metal objects. Use tools with insulated handles. CAUTION! Lead-acid batteries contain hazardous toxic materials. Handle, transport and recycle in accordance with local regulations. This UPS equipment is designed for use on a properly grounded electrical system. This equipment is intended to be installed by a qualified, certified electrician who must review and approve customer-supplied wiring, circuit breakers and earth connections to ensure compliance with technical standards and local electrical codes. Installation instructions and warning notices only for use by qualified personnel are located in the INSTALLATION section of this manual. 1 Electromagnetic Compatibility This UPS equipment complies with the requirements of the EMC directive 89/336/EEC, the published technical standards and Class A digital device pursuant to Part 15 of FCC rules. These limits provide reasonable protection against harmful electromagnetic interference in a commercial environment. This device generates, uses and radiates radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference with radio communications. Operating this device in a residential area is likely to cause harmful electromagnetic interference that the user must correct at his own expense. Operating Environment Operate the Extended Battery Cabinet in an indoor environment only in an ambient temperature range of 32 F to 104 F (0 C to 40 C). For optimum battery life, operate the unit in an ambient temperature range of 59 F to 77 F (15 C to 25 C). Install the Extended Battery Cabinet in a clean environment, free from conductive contaminants, moisture, flammable liquids, gases and corrosive equipment in an indoor environment. Turn the UPS off and isolate the system before cleaning. Use only a soft cloth, never liquid or aerosol cleaners. Keep the front and rear vents free of dust accumulation that could restrict air flow. Never block or insert any object into the ventilation holes or other openings. This Extended Battery Cabinet contains user replaceable modules. No attempts should be made to access the interior of any module. See MODULE REPLACEMENT on page 9 for details on this procedure.

GLOSSARY OF SYMBOLS Risk of electrical shock Indicates caution followed by important instructions AC input i AC output Requests the user to consult the manual Indicates the unit contains a valve-regulated lead acid battery Recycle DC voltage Equipment grounding conductor Bonded to ground AC voltage OFF ON Standby No telecommunication connection Locked position Unlocked position Contact closure signals Serial communications 2

GENERAL DESCRIPTION System Description The Extended Battery Cabinet is a modular cabinet intended for use with the Nfinity modular UPS system. The cabinet will hold a maximum of 12 battery modules with the same level of monitoring and control as the battery modules fitted in the UPS. Features: Up to four Extended Battery Cabinets can be used with a single Nfinity UPS Up to 12 battery modules per cabinet A user-friendly interface, on the UPS, for custom configuration Continuous system monitoring Warning alarms and event logs. FRONT VIEW REAR VIEW 3

PREPARATION These installation instructions provide all the information needed for positioning the Extended Battery Cabinet (including environmental requirements) and for connecting the input and output power cables. Inspection Upon receiving the Extended Battery Cabinet, examine the packaging for any signs of mishandling or damage. If any damage is noted, call your local Liebert representative and/or notify your carrier. Environment NOTE Operating in temperatures above 77 F (25 C) will reduce battery life. The environment must be free of conductive contaminants and excessive moisture (water condensation), flammable vapors, chemical fumes, or corrosive gases and liquids. Required Setup Equipment The tools below are required in order to properly set up your Extended Battery Cabinet. Pallet jack 13 mm or 1/2" wrench Flathead screwdriver #2 Phillips screwdriver Site Preparation When deciding where to locate your Extended Battery Cabinet, consider the weight and size of the unit. Make sure that the structural integrity of the floor can withstand the weight. Refer to the table below for size and fully populated weight considerations: Max Weight lbs (kg) 942 (427) H x W x D in (mm) 52" x 20" x 28" (1320 x 508 x 711) Check to make sure that your Extended Battery Cabinet will be located in a well-ventilated area with at least 300 mm (12 ) behind it. It should have at least one meter (39 in.) in front to change modules when necessary. 1 meter (39 in.) 300 mm (12 in) The unit frame is bolted to the shipping pallet to ensure safety. It is recommended that a pallet jack be used to transport the unit to its operating location (prior to unbolting the unit). 4

Unloading the Extended Battery Cabinet CAUTION! This battery cabinet is heavy (see weight on previous page). At least two people should be present to unload it from the pallet. 1. Once the Extended Battery Cabinet is near the desired operating location, remove the cardboard cover. UNLOADING 2. Use a 13 mm (1/2") wrench to remove the four mounting bolts from each of the pallet brackets. Remove mounting brackets from the pallet and cabinet. Keep brackets and bolts for future transportation of cabinet or for additional stability once in place. 3. Remove the metal ramp from the bottom of the battery cabinet, rotating it. Fit ramp in pallet slot as shown above. 4. Using two people, slowly move the cabinet down the ramp until the Extended Battery Cabinet is on a level surface. 5

5. Once the Extended Battery Cabinet is in the desired location, adjust the leveling feet to secure its position. Optional Stationary Mounting For greater stability, use a higher-grade bolt. Refer to the dimensions below when drilling holes for stationary mounting. 4.75 (120 mm) 4.75 (120 mm) Stationary Mounting 1/2" (13 mm) Additional stability can be added by bolting the mounting brackets (used in shipping) to the floor. 28 (711 mm) center line 5/16" diameter (7.94 mm) 6 places 6

INSTALLATION Grounding The Extended Battery Cabinet must be installed with a dedicated grounding electrode conductor (GEC) to the site grounding system in accordance with national and local wiring codes and regulations as shown below. DC Power DC connection with the UPS unit must be via the factory-supplied battery cables, or if longer connection cable is required, via the optional Extended Battery Cable kits. See below. L1 L2 GEC Connection Communications To enable communication between the Extended Battery Cabinet and the Nfinity, it is necessary to install an Intellislot Battery Card (IBC) in the Intellislot port of the UPS. See below. A second, included IBC is installed in the Extended Battery Cabinet. The provided serial cable is to be connected between the two cards. DC Power After connections are made and verified, the output circuit breaker must be closed to connect the batteries inside the Extended Battery Cabinet to the Nfinity UPS. To do this, move the handle of the circuit breaker under the lower-most bezel to the ON position (see illustration below for circuit breaker location). Output Circuit Breaker Communications NOTE Failure to turn on the circuit breaker may cause damage to the batteries in the Extended Battery Cabinet. Failure to follow this procedure may limit your warranty. 7

Configuration Setting For the UPS system to be aware of the presence of the Extended Battery Cabinet(s), the system has to be configured with the necessary information. To enter the information, follow the steps below: After initialization, pressing the button will take you to the main menu. Scroll down to UPS Configuration, and select it by pressing the button. Main Menu UPS Status > UPS Configuration Display Date/Time Event Log Alarm Log Transfer to Bypass Module Replacement Tools Scroll down to Change Settings; press UPS Configuration UPS Configuration Review Settings > Change Settings Service Mode Scroll down to Intellislot Battery Ca.; select it by pressing Change Settings Input Voltage Frequency Sync Range Frequency Slew Rate Set Password Auto Battery Test Low Battery Warning Auto Restart User Settings Set Date/Time Max Load Alarm Set UPS Shutdown Delay Redund Alarm Set Service Contact Remote Shutdown External Battery Bypass Alarm Mode > Intelli-Batt Ca. Air Filter Reminder Factory Defaults Enter the quantity of Extended Battery Cabinets installed. Press return arrow and then press ESC to save your changes and exit. The system is now configured. 8

MODULE REPLACEMENT Follow the instructions below when replacing a battery module and when adding modules to the system. Removing Modules 1. Remove bezel cover of appropriate module. When replacing a battery module, verify the faulty module by confirming the amber LED is lit. 2. Turn fastener counterclockwise until it is loosened. Status LED Fault LED 3. Start to pull out module. About 2/3 out it will stop. Slide module away from the center of the unit.! CAUTION Battery modules are heavy: 30 kg (66 lbs). Make sure to use two people when removing a battery module. Continue to pull until module is removed (seen at right). 4. Dispose of the removed module in an environmentally responsible way that complies with local codes and regulations or return the module to Liebert for proper disposal. NOTE Battery modules may contain shipping screws. These screws may be removed and discarded. WARNING POTENTIAL TIP HAZARD Install all modules starting with bottom bays and moving to top. For module removal, start with top bays and proceed to bottom. Do not remove more than one module at a time doing so may cause unit to tip over and cause serious injury. 9

Replacing Modules 1. Lift the module to the appropriate bay, resting the end of the module on the bay shelf. Use caution not to rest the module on the lower bezel cover. 2. Push the module into bay. Once it is half way in, slide the module sideways toward the center of the unit. Continue pushing module until fully inserted. 3. Press and turn fastener clockwise until locked. 4. Wait about 15 seconds as the module performs a start-up test and synchronizes with the other modules. Both the amber and green LEDs should be flashing. A green flashing LED will then confirm that the module is properly connected. 5. Replace the bezels. 10

BATTERY RUN TIMES Internal and Extended Battery Cabinets (minutes) Quantity of Battery Modules Quantity of Extended Battery Cabinets Load VA Load Watts 1 2 3 4 5 6 7 8 9 10 1 2 3 4 20,000 14,000 - - - - 7 9 - - - - 25 51 75 99 19,500 13,650 - - - - 7 9 - - - - 25 56 80 104 19,000 13,300 - - - - 7 9 - - - - 26 57 81 105 18,500 12,950 - - - - 8 11 - - - - 27 58 82 106 18,000 12,600 - - - - 8 12 - - - - 28 61 97 133 17,500 12,250 - - - - 8 12 - - - - 28 63 99 135 17,000 11,900 - - - - 8 12 - - - - 29 64 100 136 16,500 11,550 - - - - 9 13 - - - - 30 66 102 138 16,000 11,200 - - - 7 8 12 17 - - - 32 68 104 140 15,500 10,850 - - - 7 9 13 17 - - - 33 70 106 142 15,000 10,500 - - - 7 11 14 18 - - - 34 72 108 144 14,500 10,150 - - - 8 12 15 19 - - - 36 74 110 146 14,000 9,800 - - - 8 13 16 20 - - - 37 82 130 178 13,500 9,450 - - - 8 13 16 20 - - - 38 85 133 181 13,000 9,100 - - - 9 13 17 21 - - - 39 86 134 182 12,500 8,750 - - - 10 14 18 22 - - - 42 90 138 186 12,000 8,400 - - 7 12 16 20 24 28 - - 44 93 141 189 11,500 8,050 - - 7 12 17 21 25 29 - - 46 97 145 193 11,000 7,700 - - 7 12 17 21 26 30 - - 48 101 149 197 10,500 7,350 - - 8 14 18 23 28 32 - - 51 111 171 231 10,000 7,000 - - 9 15 19 24 29 34 - - 54 113 173 233 9,500 6,650 - - 10 15 21 26 30 36 - - 57 119 179 239 9,000 6,300 - - 11 16 22 28 33 38 - - 60 131 203 275 8,500 5,950 - - 12 17 23 29 35 40 - - 64 139 211 283 8,000 5,600-7 13 19 25 31 37 43 49-68 142 214 286 7,500 5,250-8 14 21 28 34 40 47 53-73 149 221 293 7,000 4,900-8 16 23 30 36 43 50 57-78 161 245 329 6,500 4,550-9 17 24 32 40 47 55 62-84 174 258 342 6,000 4,200-11 19 24 36 43 51 60 68-92 190 286 382 5,500 3,850-12 21 23 39 47 56 66 74-101 203 299 395 5,000 3,500-14 23 28 42 52 61 72 80-110 223 331 439 4,500 3,150-15 25 37 47 57 67 78 88-119 245 365 485 4,000 2,800 7 19 31 43 55 66 79 91 104 115 140 285 429 573 3,500 2,450 9 23 37 51 65 79 93 107 123 136 165 333 489 645 3,000 2,100 11 28 44 60 76 93 109 126 143 159 192 387 567 747 2,500 1,750 14 33 52 71 89 109 128 147 167 185 224 448 652 856 2,000 1,400 18 42 65 88 112 136 160 183 207 230 276 554 818 1,082 1,500 1,050 26 57 87 119 151 182 213 243 276 306 367 734 1,094 1,454 1,000 700 45 94 144 195 246 294 344 393 444 493 570 1145 1,685 2,225 900 630 50 105 160 216 273 327 382 436 492 547 627 1261 1,849 2,437 800 560 55 116 177 238 300 359 420 480 540 601 684 1378 2,014 2,650 700 490 61 128 195 263 331 396 463 529 594 661 752 1515 2,223 2,931 600 420 72 149 227 304 382 457 535 610 685 762 887 1776 2,628 3,480 500 350 82 171 258 346 433 518 606 691 777 862 1022 2036 3,032 4,028 NOTE: Backup times are in minutes and are based on resistive loading at an ambient temperature of 77 F (25 C). Extended battery cabinets are fully loaded with 12 battery modules. Extended battery cabinets assume that the UPS frame is fitted with all available battery modules. 11

12

POWER PROTECTION Extended Battery Cabinet for Nfinity USER MANUAL The Company Behind the Products With over a million installations around the globe, Liebert is the world leader in computer protection systems. Since its founding in 1965, Liebert has developed a complete range of support and protection systems for sensitive electronics: Environmental systems close-control air conditioning from 1 to 60 tons Power conditioning and UPS with power ranges from 300 VA to more than 1000 kva Integrated systems that provide both environmental and power protection in a single, flexible package Monitoring and control from systems of any size or location, on-site or remote Service and support through more than 100 service centers around the world and a 24/7 Customer Response Center While every precaution has been taken to ensure the accuracy and completeness of this literature, Liebert Corporation assumes no responsibility and disclaims all liability for damages resulting from use of this information or for any errors or omissions. 2002 Liebert Corporation All rights reserved throughout the world. Specifications subject to change without notice. Liebert and the Liebert logo are registered trademarks of Liebert Corporation. All names referred to are trademarks or registered trademarks of their respective owners. Technical Support United States 1050 Dearborn Drive P.O. Box 29186 Columbus, OH 43229 Single-Phase UPS 800-543-2378 Outside the United States 614-841-6598 3-Phase UPS 800-543-2378 Environmental Control 800-543-2778 Italy Via Leonardo Da Vinci 8 Zona Industriale Tognana 35028 Piove Di Sacco (PD) +39 049 9719 111 FAX: +39 049 5841 257 Asia 23F, Allied Kajima Bldg. 138 Gloucester Road Wanchai Hong Kong +852 2 572 2201 FAX: +852 2 831 0114 Web Site www.liebert.com SL-23966 (3/02) Rev. 2