APPLICATION NOTE Electrostatic Discharge Protection on QuickStick Systems

Similar documents
APPLICATION NOTE QuickStick 100 Power Cable Sizing and Selection

QuickStick Repeatability Analysis

MagneMotion Maglev Demonstration on ODU Guideway

Service Note. Installing/Replacing Antistatic tape on SPINJET 4000 January Static Charge. Humidity. Grounding. Earthed mains outlet

Series 206/208 Through-Hole DIP Switch

Static Discharge Ignition of Combustible Atmospheres

INSTALLATION INSTRUCTIONS

SynJet MR16 LED Cooler with Heat Sink

ESD Tests on Protektive Pak Versus Coated ESD Boxes

ELIMINATION OF REPETITIVE THRUST BEARING FAILURES ON A PROCESS AIR COMPRESSOR

CABLE DRAG CHAIN SYSTEMS

ELECRAFT KX3 Application Note

Automotive Sensor Products

Operating instructions. FreeCon Contactless Power Contactless power transmission IE-CL240W-PP-BASE IE-CL240W-PP-REMOTE

AutoLink Frequently Asked Questions

Chapter 5 FOUNDATION. 2010, The McGraw-Hill Companies, Inc. 2010, The McGraw-Hill Companies, Inc.

ASSA ABLOY. 7100SZ Series SafeZone External Sensor. Installation and Instruction Manual ASSA ABLOY. Patent Pending

Mounting instructions for LinPak modules

18VDC ESB6-X Series Cordless Screwdrivers Operation Manual

BMW i. Freude am Fahren. Wallbox PURE. Installation instruction

HIGH BRIGHTNESS LED LIGHT BAR PRELIMINARY SPEC. Features. Package Dimensions

PRODUCT CATALOGUE 2016

RE22 Airbag Systems, Side

Basic Electrical Safety

type r remote drive for auxiliary

Kawasaki Ninja 250R / 2013 Kawasaki Ninja 300 Z-Fi QS / TC Installation Instructions P/N T442S, T442R

LPI Lightning Capturing System: Guardian System 5 for Cat I, Cat II and Cat III Air Terminals

WARNING! USE ONLY IN RACE OR OTHER CLOSED COURSE APPLICATIONS AND NEVER ON PUBLIC ROADS

QS 100 LSM Power Management

QuickStick 100 User s Manual

Technical Manual MSI Hydraulic Adjustable Choke

Part Number Revision NC, September High Temperature Velocity and Acceleration Sensor Operation and Maintenance Manual

Installation Guidelines for Dukane Probes Used in Automation

Power & High Voltage Joslyn Hi-Voltage Overhead Reclosers & Switches H-220. Series HVI Hi-Velocity Interrupter Attachment

(with Class-1 AC resistive load) 3. G3PB-215B-2N-VD kW max. (25 A) G3PB-225B-3N-VD 2. G3PB-225B-2N-VD kw max. (35 A) G3PB-235B-3N-VD 2

Static Discharge Ignition of Combustible Atmospheres. White Paper. Author Details: ungrounded vacuum tankers and road tankers.

Power Management Solution: Constant Voltage (CV) Pulse Charging of Hybrid Capacitors

Installation Guide. Blind Spot Detection / ADVBSD20 REV. A

Phase Leg IGBT with an Integrated Driver Module

VAN DE GRAAFF GENERATORS - 400kV

Industrial Power Supplies

INSTALLATION INSTRUCTIONS for HI-1 and HI-2 MOTORCYCLE IGNITIONS. Part Numbers and INTRODUCTION COIL AND SPARK PLUG CABLE CONSIDERATIONS

USB3.0 For Active Optical Cable SPECIFICATIONS

Description. Applications

18VDC ESB6 Series Cordless Screwdrivers Operation Manual

WARNING! USE ONLY IN RACE OR OTHER CLOSED COURSE APPLICATIONS AND NEVER ON PUBLIC ROADS

Signet Temperature Transmitter

MSD-8 Plus Ignition PN 7805

Signet Pressure Transmitter

Contacts The moveable contact, which is the one affected by the armature is sometimes referred to as the hinge contact.

Troubleshooting Guide

LP Series Label Feeders

Grounding Systems. Equipment Grounding & Grounded Conductors

PROCEDURE NAME: DEPT: 030 REVISION LEVEL: A DATE EFFECTIVE: 11/13/07 DAF# 00396

MSD-8 Plus Ignition PN 7805

201A-9 INSTALLATION INSTRUCTIONS. Revision A1 Rapid City, SD, USA, 01/2010

USB3.0 For Active Optical Cable SPECIFICATIONS

SL Series Application Notes. SL Series - Application Notes. General Application Notes. Wire Gage & Distance to Load

Why Orion BMS Internal Fuses Blow

OPERATION MANUAL MODELS TWE-250 TWE-321 TWE-375 TRU WELD EQUIPMENT COMPANY 6400 N. HONEYTOWN ROAD SMITHVILLE, OHIO (330)

WARNING! USE ONLY IN RACE OR OTHER CLOSED COURSE APPLICATIONS AND NEVER ON PUBLIC ROADS

SECTION 15. GROUNDING AND BONDING

ELECRAFT K3 HIGH-PERFORMANCE METER TRANSCEIVER INSTALLING CRYSTAL I.F. FILTERS. Rev A, October 15, 2007

ATOTH-G Series BLDC Motor Controller. User s Manual

MGL Avionics AvioGuard. Fault protected, wide input range, isolated, DC to DC converter for avionics applications

Technical Service Bulletin IOX/DCX Transmitter Maintenance Schedule

Explosion-Proof Painting Robots

Shaft Grounding Rings. Protecting VFD Driven Motors from Bearing Currents

LinkPro High Voltage Adapter Installation and Wiring Guide. Initial Release 01/14/10 Rev 1.0

Service Bulletin Trucks Date Group No. Supp. Page

Thank you for purchasing a kit from SparKIT. Your support is greatly appreciated.

STEALTH INTERNATIONAL INC. DESIGN REPORT #1001 IBC ENERGY DISSIPATING VALVE FLOW TESTING OF 12 VALVE

Installation Instructions and Owner s Manual

DYNAMIC ENGINEERING 150 DuBois St Suite C, Santa Cruz Ca Fax Est.

Overview. Chassis Packaging

Li-ion Battery Specification

X-Ray Tube Specifications Maximum Peak Voltage kv Anode to Ground kv Cathode to Ground kv

Static Electricity Hazards and Controls. Dirk Smith, President Ionix Gas Technologies

Companion II 8.3kV, 17.2kV and 23kV 12K - 40K Backup Fuses

WARNING! USE ONLY IN RACE OR OTHER CLOSED COURSE APPLICATIONS AND NEVER ON PUBLIC ROADS

Motorized Electric Latch Retraction

PMC-MC-X2-Chassis PMC-MC-X4-Chassis

ESD Static Dissipative Dispensing Components

Orion BMS Purchasing Guide Rev. 1.2

0.5 s to 30 h (30 s, 3 min, 30 min, 3 h, 30 h)

Installation. minnkot amot or s.com

MSD Circle Track Ignition PN 6427

Installation Instructions

PowerFlex 700S and 700H Fan Inverter Upgrade Kit (Frame 10-11)

BE SURE POWER IS DISCONNECTED PRIOR TO INSALLATION! FOLLOW NATIONAL, STATE, AND LOCAL CODES! READ THESE INSTRUCTIONS ENTIRELY BEFORE INSTALLATION!

Power Management Solution: Constant Voltage (CV) Pulse Charging of Hybrid Capacitors

Description. Applications

SOLITRON MIDI - With Integrated Heatsink Types RJ1A, RJ1B

PREVENTING VFD/AC DRIVE INDUCED ELECTRICAL DAMAGE TO AC MOTOR BEARINGS

Synthesis Twin. from 6 to 20 kva

4.4. Forces Applied to Automotive Technology. The Physics of Car Tires

Suzuki Burgman

REARSIGHT PART NUMBER: Code: MC1 RECOMMENDED SEQUENCE OF APPLICATION

RollSeal 1733 County Road 68 Bremen, Alabama Part No Rev Owner s Manual RS-Divider Curtain

Basic Electronics, Reliable Wiring, and Mitigating ESD in FTC Robots FTC Kick-Off

Transcription:

APPLICATION NOTE Electrostatic Discharge Protection on QuickStick Systems Purpose This application note presents both the Electro-static Discharge (ESD) rating of the QuickStick (QS) system and methods to prevent the motors from experiencing discharges that exceed this rating. Introduction As in any system with electrically isolated moving components, there is the possibility that the vehicle on a QuickStick system will build up a static charge. Alternately, a charge can be placed on the vehicle while the system is interacting with other machinery. If not dissipated, the potential difference between the vehicle and ground can eventually build to the point where electricity will arc from the vehicle into the nearest grounded object. In many cases, this is the grounded case of the QuickStick motor. If a motor is hit with an electrostatic discharge, there is a chance that this can trigger abnormal operating conditions such as resetting one or more of the internal processors. The vehicle will not be able to continue forward when it reaches the region of the track controlled by that processor. The motor must be reset to reload the configuration into the processors in order to allow them to be used again. Regular electrostatic discharges into the motor for a prolonged period of time can reduce the life of the motor and will interrupt line operation. Component ESD Rating The QS100 is CE compliant and the pertinent Electrostatic Discharge (ESD) levels can be found in EN61000-6-2:2005 Immunity for industrial environments. The heavy industrial limits were used when testing. This testing verifies that the unit tested was not reset by an 8 kv non-contact discharge (arcing though the air) or by a 4 kv contact discharge. Component Protection Electricity will take the path of least resistance from the point where the charge has built up to ground. To protect a component from ESD, that component must not be the shortest route to ground. In Figure 1, the image on the left depicts a system where the path of least resistance is through the QS motor. The figure on the right depicts the ideal situation where the vehicle is 139 Barnum Road, Devens, MA 01434 Page 1 of 6 FM-752-012 Rev. A

grounded via a path that does not include the motor. Figure 1: Possible Discharge Paths from the Vehicle Discharging the Vehicle In order to cross the air gap between the vehicle and the motor, the potential difference between the vehicle and ground must be great enough to allow it to overcome the resistance of the air between the motor and vehicle. To prevent the vehicle from discharging into the motor, provide an alternate discharge path that will trigger at a lower potential difference. Ideally, a vehicle would be constantly grounded, which would prevent any charge from building as it would immediately go to ground. Static Brushes This is MagneMotion s recommended method for preventing static discharges into the motor. A static brush is a conductive brush mounted to the vehicle that is preferably constantly in contact with the grounded track. The brush can either act as a permanent connection to ground or as a discharge point with an extremely low resistance. This method will keep static from building appreciably, preventing any arcing to the motors or track. All parts of the vehicle that can retain a charge must be electrically connected to this brush to prevent isolated components from building up a charge. Figure 2 displays one example of a guiderail system using a static brush. Please note that some coatings, such as anodizing, on surfaces contacting the static brushes are insulating and can break the discharge path. 139 Barnum Road, Devens, MA 01434 Page 2 of 6 FM-752-012 Rev. A

Favorable Discharge Point Figure 2: An Example Use of a Static Brush An alternative to using a static brushes would be to establish an extremely favorable discharge point where arcing is allowed to occur. This can be done by modifying the vehicle such that there is a point on the vehicle closer to the track than to the motor with more favorable electrical conductivity on both the vehicle and track at the gap. Sharp points are preferred discharge points. The goal of this method is to create a point where the electricity will arc at a lower potential level than is required to arc to the motors. This method allows a much larger charge to build than using a static brush, but does not require the additional rubbing contact between the brush and track. Figure 3: Discharge through a Favorable Point 139 Barnum Road, Devens, MA 01434 Page 3 of 6 FM-752-012 Rev. A

Conductive Wheels and Bearings The vehicle can also be grounded using the existing contact points between the wheels and track. If conductive wheels and bearings are used, then the vehicle will be grounded through the wheels and unable to build up charge. All components capable of holding a charge must be electrically tied to the wheels for this method to be effective. Most bearings have packing grease which may lead to an intermittent conductive path from the vehicle to the guideway. Ideally, the bearing selected should have conductive lubrication. A bearing that is made out of conductive materials may not conduct energy between its inner and outer race if there is no path between them. Figure 4: Discharge Through a Wheel 139 Barnum Road, Devens, MA 01434 Page 4 of 6 FM-752-012 Rev. A

Protecting the Motor Instead of preventing discharges from the vehicle through the motor, it is possible to instead redirect the discharge around the motor. By tying the upper surface of the motor directly to ground though the use of conductive tape or wires, the charge has an alternative path of less resistance than through the internal components on the way to ground. Summary Figure 5: Protecting the Motor from Discharge By providing the electrical energy a route to ground other than through the motor, sudden system stoppages due to a static discharge can be prevented. Any one of the above methods should be sufficient to prevent the discharge of static through the motor. Multiple methods can be used to create redundancy. 139 Barnum Road, Devens, MA 01434 Page 5 of 6 FM-752-012 Rev. A

Related Documents: 990000460 QuickStick 100 User s Manual 990000496 QuickStick HT User s Manual More Information MagneMotion Website: www.magnemotion.com Questions & Comments: www.magnemotion.com/about-magnemotion/contact.cfm Revision History Rev. Change Description A Initial release 139 Barnum Road, Devens, MA 01434 Page 6 of 6 FM-752-012 Rev. A