Pressure transducers. with flush connections. Pressure transducers. with SIL assessment. HydroFox for level measurement

Similar documents
Pressure transducer DMU 01K Compact version

DMP 331P. Industrial Pressure Transmitter. Pressure Ports And Process Connections With Flush Welded Stainless Steel Diaphragm

DMP 331P DMP 331P. Industrial Pressure Transmitter. Pressure Ports And Process Connections With Flush Welded Stainless Steel Diaphragm

DMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor

DMK 331P. Industrial Pressure Transmitter. Pressure Ports With Flush Welded Stainless Steel Diaphragm

DMP 331 DMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor. Pressure Transmitter. Industrial

DMK 331P. Industrial Pressure Transmitter. Pressure Ports With Flush Welded Stainless Steel Diaphragm. accuracy according to IEC 60770: 0.

DMP 333. Industrial Pressure Transmitter For High Pressure. Stainless Steel Sensor

DMK 331P DMK 331P. Industrial Pressure Transmitter. Pressure Ports With Flush Welded Stainless Steel Diaphragm. Pressure Transmitter.

XMP ci. Process Pressure Transmitter with HART -communication. Ceramic Sensor. accuracy according to IEC 60770: 0.1 % FSO.

SITRANS P measuring instruments for pressure

Pressure transmitter for industrial applications Type MBS 4510

Differential Pressure Sensors

LMK 387. Stainless Steel Probe. Ceramic Sensor. accuracy according to IEC 60770: standard: 0.35 % FSO option: 0.25 % FSO

Pressure Transmitters for Sanitary Applications Model SA-11

Differential Pressure Sensors

Type A-10 General Purpose Pressure Transmitters

OEM Pressure Transmitters

SSI Technologies Application Note PS-AN2 MediaSensor Absolute & Gage Pressure Transducers & Transmitters Product Overview

DCT 533. Industrial Pressure Transmitter with IO-Link Interface. Stainless Steel Sensor

DMP 331. Industrial Pressure Transmitter for Low Pressure DRUCK & TEMPERATUR LEITENBERGER GMBH. Stainless Steel Sensor

Pressure transmitter COMPACT ECOnomic

Pressure transmitters for industrial applications Type MBS 4510

Instruction Manual. Pressure Transducer DMU 01, DMU 03, DMU 04, DMU 05, DMU 07, DMU 08, DMU 09, DMU 10, DMU 11

Pressure sensor for liquid and gaseous media QBE620-P...

SPT- I / U PRESSURE TRANSMITTER for general applications

Pressure Precision. Description. Features. Measuring ranges. Applications. with front-flush diaphragm for gauge pressure and absolute pressure

Thermal hysteresis 0.5% max. of full scale (within compensated temperature range) 1% max. for ranges mbar mbar mbar

JUMO MIDAS Pressure transmitter

Differential pressure gauge Model , copper alloy Model , stainless steel version

Pressure Transmitter. Pressure transmitter with compact design Model EDC-K. Electronic. Applications. Special Features.

Industrial Pressure Transmitters

PRESSURE TRANSMITTER PYRP-28 INDUSTRIAL & INTRINSICALLY SAFE PRESSURE TRANSMITTER PRESSURE TRANSMITTER

PRESSURE TRANSDUCERS. Specifications. Individual Specifications

JUMO dtrans p20. Process pressure transmitter. Type Brief description. Key features. Block diagram

Differential Pressure Gauges Cryo Gauge Model , Cu-alloy Model , Stainless Steel Series

OEM pressure transmitter with thin-film technology For mobile hydraulics Model MH-2

DMP 333. Industrial Pressure Transmitter For High Pressure DRUCK & TEMPERATUR LEITENBERGER GMBH. Stainless Steel Sensor

Flush-mounted pressure and level transmitters - KERAMESS KS series 100/101 -

LMK 387. Stainless Steel Probe DRUCK & TEMPERATUR LEITENBERGER GMBH. Ceramic Sensor

JUMO MIDAS S05 Pressure transmitter Type

Pressure transmitter for elevated media temperatures

Electronic Pressure Switches

Pressure Transmitter JUMO dtrans p30 Type

PRESSURE TRANSDUCERS. Specifications. Individual Specifications

Pressure Sensors. for liquid and gaseous media

JUMO dtrans p20. Process pressure transmitter. Brief description. Special features. Block diagram. Approvals/approval marks (see "Technical data")

Type E-10, E-11 Hazardous Area Explosion-proof Transmitters

Pressure transmitters for heavy-duty applications MBS 2000 and MBS 2050

ABB Instrumentation. 50T Series Transmitters Model 54G/A gauge/absolute pressure transmitter for sanitary use. Specification sheet

DM01. Battery Powered Precision Digital Gauge. Stainless Steel Sensor. class 0.05

DL 01. Battery Powered Precision Digital Gauge for Leak Testing. Stainless Steel Sensor. class 0.05

Electronic Pressure Switches

Pressure transmitters for heavy duty applications MBS 8200 and MBS 8250

More Precision. mainsensor Magneto-inductive displacement sensor

CTE9000 / CTU9000 Series OEM pressure transmitters for industrial media

Pressure transmitter for general applications Model S-10, standard version Model S-11, flush diaphragm

JUMO DELOS SI. Precision pressure transmitter with switching contacts and display. Application. Brief description. Key features.

JUMO MIDAS S06. OEM-Pressure Transmitter Low Pressure. Applications. Brief description. Customer benefits. Special features

High temperature pressure transmitters for heavy-duty applications MBS 2200 and MBS 2250

JUMO MIDAS C18 SW. OEM pressure transmitter - seawater. Applications

PRESSURE BENCH OPERATING INSTRUCTIONS

OEM Pressure Transmitters

PPT 802, Proximity Probe Transducer System

Pressure Transmitter Series TST Pressure Range bar, mbar, bar Output Signals ma, V

Compact Pressure Transmitter DAN-HH

JUMO dtrans p02. Pressure transmitter. General application. Approvals/marks of conformity. Data Sheet Page 1/6. II 1/2G Ex ia IIC T6 Ga/Gb

Ultra High Purity Transducer, Ex na nl Models WU-20, WU-25 and WU-26

CTE8000 / CTU8000 Series

Differential Pressure Sensors

JUMO dtrans p35. Pressure Sensor with IO-Link. Application. Brief description. Customer benefits. Special features

Miniature resistance thermometer For sanitary applications Model TR21-A, with flange connection

Pressure transmitters for heavy duty applications MBS 3200 and 3250

G 1/4 A DIN 3852 (bar version) ±0.5 %FS max

Level sensor Magnetostrictive, high-resolution measurement principle Model FLM-H, for sanitary applications

M5200 Industrial Pressure Transducer

OEM Pressure transmitter for industrial applications Type MBS Technical brochure

SATRON VTe pressure transmitter

ECT Applications. Features

Honeywell Zephyr TM Analog Airflow Sensors. HAF Series High Accuracy ±50 SCCM to ±750 SCCM

Differential pressure sensor

Solid State Electronic Pressure Switch with Integral LED Display Model PSD-10

SATRON VDt Differential Pressure Transmitter

Type A-10 General Purpose Pressure Transmitter

Pressure transmitter for industrial applications Type MBS 4500

Pressure measurement. Process pressure VEGABAR 14 VEGABAR 17. Product Information

Seal material. Pressure range. Pressure connection -40 F +212 F 1 -4 F +257 F 3

SATRON VT Pressure Transmitter

CTE7000 / CTU7000 Series Miniature pressure transmitters

JUMO dtrans p20 DELTA

Pressure transmitter for general industrial purposes MBS 3000 and MBS 3050

SSI Technologies Application Note PS-AN7 MediaGauge (Model MG-MD) Digital Pressure Gauge Product Overview

Adjustment range. Seal material. Pressure connection

OEM Pressure Transmitters for heavy-duty applications Type MBS 1200 and MBS 1250

JUMO MIDAS S07 MA. OEM Pressure Transmitter - Maritime Approved. Applications. Brief description. Special features.

Pressure Transmitter JUMO dtrans p30 Type

ETP80. Electronic Transmitter for Pressure, Differential Pressure and Level

Differential Pressure Sensors

Technical Datasheet P-30/P-31. Standard transmitter.

Intrinsically safe presure transmitters for hazardous environments Type MBS 4201, MBS 4251, MBS 4701 and MBS Technical brochure

Transcription:

with flush connections with SIL assessment HydroFox for level measurement OEM version

CHPTER Electronic pressure measuring instruments:, digital pressure gauges, pressure switches OVERVIEW Selection table pressure transducers 94 Technical information pressure transducers 96 OEM VERSION DMU 600/20 compact version 98 DMU 0K compact version 99 MECHNICL ENGINEERING DMU 0 standard version 200 PROCESS ENGINEERING DMU 02 industrial version 204 DMU 02 Vario programmable 206 DMU 02 Vario flush 207 DMU 0 industrial version 2 DMU 04 industrial version 27 DMU 05 P precision version 29 HydroFox DMU 07 for level measurement 22 HydroFox DMU 08 level probe 225 HydroFox DMU 08 T level probe with temperature measurement 227 HydroFox DMU 09 level probe, for chemical applications 229 DeltaFox DMU 0 D version for differential pressure measurment 2 DeltaFox DMU D version for differential pressure measurment 2 Differential pressure switches DS 0 24 PROCESS ENGINEERING DMU with local display 27 QULITY SSURNCE Universal digital pressure gauges DIM 20 service instrument 29 9

Overview DMU 600/20 DMU 0 DMU 02 DMU 02 Vario DMU 0 DMU 04 Smallest measuring range 0/4 bar 0/ bar 0/600 mbar 0/ bar 0/00 mbar 0/00 mbar Largest measuring range 0/40 bar 0/400 bar 0/2,000 bar 0/000 bar 0/600 bar 0/400 bar 4 20 m Output 0 0 V ± % FSO ccuracy ± 0.5% FSO ± 0.5% FSO ± 0.% FSO Stainless steel Wetted parts Stainless steel, FKM Stainless steel, ceramic (L 2O ), FKM Stainless steel, silicon, glass, silicone luminium, silicon, glass, silicone, PUR No pressure transmission liquid Paraffin oil, FD Silicone oil Pressure transmission Connection thread 94 Process connection Hygienic connections Flanges ISO 4400 connector Electrical connection M2 x Fixed cable connection Cable gland Temperature of the medium 00 C pplication area Temperature of the medium > 00 C Temperature of the medium > -25 C Temperature of the medium -25 C Measuring range spread Indication of measured values Evaluation TEX certificate SIL assessment *** Negative pressure (vacuum) pplication areas Relative pressure measurement bsolute pressure measurement Differential pressure measurement Measurement of water / waste water Measurement of oils Measurement of chemicals Measurement of food Measurement of pharmaceuticals Measurement of crystallising media Measurement of gases Measurement of liquids * Depends on measuring range. ** ccuracy of mechanical local display. *** Depends on version. Page 98 Page 200 Page 204 Page 206 Page 2 Page 27

Overview DMU 05 P DMU 07 DMU 08 DMU 09 DMU 0 D DMU D DMU DIM 20 0/00 mbar 0/40 mbar 0/00 mbar 0/40 mbar 0/6 mbar 0/20 mbar 0/600 mbar 0/ bar 0/600 bar 0/20 bar 0/25 bar 0/0 bar 0/ bar 0/6 bar 0/40 bar 0/700 bar * ** * Page 29 Page 22 Page 225 Page 229 Page 2 Page 2 Page 27 Page 29 95

Technical information pplication are used for electronic pressure measurement in many industrial and building applications. Various measuring principles, output signals, materials, pressure transmission liquids and process connections allow pressure transducers to be used in almost any application. Pressure transducer versions are available for abrasive, pure, highly viscous, viscous or crystallising media as well as special models for hygienic processes. Typical applications areas Pneumatic/hydraulic Gas industry Process engineering Pharmaceutical and biotechnology applications Chemical industry and petrochemical industry Medical technology Laboratory applications Food applications Water treatment Waste water applications Mechanical and plant engineering utomation Filter monitoring Heating, refrigeration, air conditioning utomotive industry Connection technology with numerous versions, diffusion-tight and extremely robust: pressure transducer DMU 02 Vario Description convert physical pressure into an electrical signal proportional to the pressure. Different pressure transducer versions are available which use a variety of measuring principles serving as the basis for sensing the pressure. Measuring principle and measuring cell Piezo-resistive polysilicon stainless steel measuring cell (thin film) n isolation layer made of non-conductive silicon oxide is coated to the stainless steel diaphragm (a high-precision part calculated in view of the force path) on the side facing away from the pressure; after that, polysilicon is deposited. Semiconductor resistors are etched from this layer; a gold layer provides contacts. When pressure is applied and causes a deflection, the resistance changes. s compared to conventional strain gauges (conductors), polysilicon semiconductor sensors have a higher output signal. Since the measuring cell is made of stainless steel, it can be directly welded to the process connection. This helps to prevent leaks caused by fatigue of the sealing material. These robust measuring cells are insensitive to shock and vibration and have a high resistance to overloads. They are used for pressure measurements from 600 mbar up to several thousand bar. with polysilicon stainless steel measuring cells: DMU 02, 02 Vario Benefits Robust measuring cell High resistance to chemicals No seal No internal transmission liquid High output signal High long-term stability Shock- and vibration-resistant 96 Division II

Technical information Measuring principle and measuring cell Piezo-resistive silicon measuring cells The function principle of piezo-resistive silicon measuring cells is based on a silicon chip with measuring resistors in the diaphragm. When pressure is applied and causes a deflection, the resistance changes. s opposed to open measuring cells which can only be used with certain, non-corrosive media, the silicon chips of encapsulated measuring cells are contained in a gas-evacuated protective housing filled with transmission liquid; this housing is closed with an elastic diaphragm at the pressure side. If the diaphragm is deflected as a result of the application of pressure, the transmission liquid is displaced towards the sensor. Silicon measuring cells are highly sensitive and have a high output signal. This allows for measurements at very low pressures and provides for high chemical resistance. with encapsulated silicon stainless steel measuring cells: DMU 0, 04, 05, 08,, 2, with open silicon measuring cells: DMU 0 D, 600/20 Benefits High resistance to chemicals High output signal Very small measuring ranges possible High accuracy Measuring principle and measuring cell Piezo-resistive and capacitance ceramic measuring cells luminium oxide (l 2O ) that is resistant to almost all chemicals is used for ceramic measuring cells. Piezo-resistive thick-film measuring cells consist of a base and a diaphragm made of aluminium oxide ceramic. During the production process, measuring resistors are burnt into the side of the diaphragm facing away from the medium; they change when pressure is applied to the diaphragm and causes a deflection. Ceramic thick-film measuring cells are used for medium pressure from bar to up to 400 bar. Capacitance ceramic measuring cells use a ceramic base and a ceramic diaphragm which are gold-coated on the side facing away from the pressure. The gold coating forms the electrode pair of a capacitor; they are positioned at a distance of just a few µm away from each other. Pressure causes a deflection of the diaphragm and the capacitance changes. Capacitance ceramic measuring cells are used for low pressures from 00 mbar to up to 60 bar; they have a high overload resistance. Both measuring cell types are mounted to the process connection via elastomer seals. The use of ceramic measuring cells is only limited by the chemical resistance of the seals. Different pressure loads and pressure measuring ranges can be obtained by varying the thickness of the diaphragm. with piezo-resistive thick-film ceramic measuring cells: DMU 0K, 0, 0 VM and DIM 20 with capacitance ceramic measuring cells: DMU 07, 09 Benefits Robust measuring cell High resistance to chemicals brasion-resistant No internal transmission liquid No chemical seal required Division II 97

OEM version DMU 600/20 Compact version Special OEM unit Compact design Superior price/performance ratio due to automated large-scale production High pressure resistance Without transmission liquid Dimensions (mm) Page 7 Page 72 Page 7 pplication Description Electronic pressure measurement for media such as air, chemical gases (humidity: 0 to 85 % rh, not condensing), water, oil, petrol. Not suitable for media which react with glass, silicon, stainless steel 04 or silicone glue. convert physical pressure into an electrical signal proportional to the pressure. DMU 600/20 is equipped with a piezo-resistive silicon measuring cell. Technical specifications Options Measuring accuracy Deviation from the characteristic curve according to IEC 60770 limit point calibration (non-linearity, hysteresis, repeatability): <± % FSO Measuring ranges Relative pressure: 0/4 bar to 0/40 bar Overpressure safety t least 2 x FS (burst pressure at least 2 x FS) Operating temperature range Medium: -25/+85 C mbient: -25/+85 C Storage: -40/+85 C Temperature error band In compensated range -0/+70 C < 0.2 % FSO/0 K Dynamic characteristics Response time < ms Process connection G¼B, DIN 852 type E Materials Housing: Stainless steel 04 Pressure connection: Stainless steel 04 Diaphragm: Seal: Silicon, glass Silicone Supply voltage DC 9 2 V Output signal 4 20 m, 2-wire Load UB 4 20 m UBmin 0.02 Current input 4 20 m < 25 m Electrical protection Short circuit proof and protected against reverse polarity Electrical connection/degree of protection Connector and junction box as per ISO 4400 (DIN 4650-), IP 65 CE conformity (EMC) EMC Directive 2004/08/EC Other measuring ranges Other process connections Other electrical connections Fixed cable connection Other output signals DG: H, PG: 4 e.g. 0 0 V, 5 V bsolut pressure version Measuring range Part no. Price 0/4 bar 50-005 0/6 bar 50-006 0/0 bar 50-007 0/6 bar 50-008 0/25 bar 50-009 0/40 bar 50-00 Minimum order quantity 50 pieces 98 Division II

OEM version DMU 0K Compact version Special OEM unit Proven ceramic technology No mechanical ageing of the measuring cell Superior price/performance ratio due to automated large-scale production Compact design Without transmission liquid Wiring diagram (4 20 m, 2-wire) Page 7 Page 72 Page 7 Supply - pplication Description For electronic pressure measurement in industrial or HVC applications (such as hydraulic, pneumatic, automation, heating or air conditioning). convert physical pressure into an electrical signal proportional to the pressure. DMU 0K is equipped with a piezo-resistive thick-film ceramic measuring cell. Technical specifications Measuring accuracy Deviation from the characteristic curve according to IEC 60770 limit point calibration (non-linearity, hysteresis, repeatability): < ± % FSO Measuring ranges Relative pressure: 0/.6 to 0/250 bar Overpressure safety t least 2 x FS except for 250 bar: Overload max. 400 bar (burst pressure at least x FS) Operating temperature range Medium: -25/+25 C mbient: -25/+85 C Storage: -40/+85 C Temperature error band In compensated range -25/+85 C 0.5 % FSO/0 K (typ.) Dynamic characteristics Response time: 2-wire: 0 ms -wire: ms Process connection G¼B, DIN 852 type E Material Housing: Stainless steel 04 Pressure connection: Stainless steel 04 Diaphragm: Ceramic (l 2O 96 %) Seal: FKM (Viton) Supply voltage 2-wire DC 8 2 V Output signal 4 20 m, 2-wire Load 2-wire: R max = [(U B U Bmin) / 0.02 ] Ω Current input 4 20 m < 25 m Electrical protection Short circuit proof and protected against reverse polarity Electrical connection/degree of protection Connector and junction box as per ISO 4400 (DIN 4650-), IP 65 CE conformity (EMC) EMC Directive 2004/08/EC Dimensions (mm) Options Fixed cable connection Other output signals Other connection threads Output signal 0 0 V, -wire i See page 202 for prices. Division II 99

Mechanical engineering DMU 0 Standard version Proven ceramic technology No mechanical ageing of the measuring cell No transmission liquid Versions for relative pressure and absolute pressure Small temperature error Page 7 Page 72 Page 7 pplication Description For electronic pressure measurement in industrial applications (such as hydraulic and pneumatic applications as well as mechanical and plant engineering). convert physical pressure into an electrical signal proportional to the pressure. DMU 0 is equipped with a piezo-resistive thick-film ceramic measuring cell. Technical specifications Measuring accuracy Deviation from the characteristic curve according to IEC 60770 limit point calibration (non-linearity, hysteresis, repeatability): < ±0.5 % FSO (measuring range -/0 bar < ± % FSO) Measuring ranges Relative pressure: -/0 to 0/400 bar bsolute pressure: 0/ to 0/400 bar Overpressure safety t least 2 x FS, except for: 250 bar: Overload 400 bar 400 bar: 650 bar (burst pressure at least x FS, except 400 bar: burst pressure =,000 bar) Operating temperature range Medium: -25/+25 C mbient: -25/+85 C Storage: -40/+85 C Temperature error band In compensated range -25/+85 C ± 0. % FSO/0 K Dynamic characteristics Response time 2-wire 0 ms -wire ms Process connection G½B (EN 87-/7.) or G½B DIN 852 type E with flush diaphragm (DMU 0 VM up to max. 0/25 bar, enquire for absolute pressure ranges) Materials Housing: Stainless steel 04 Pressure connection: Stainless steel 04 Diaphragm: Ceramic (l 2O 96 %) Seal: FKM (Viton) Supply voltage 2-wire DC 8 2 V -wire DC 4 0 V Output signal 4 20 m, 2-wire 0 0 V, -wire Load 2-wire: R max = [(U B U Bmin) / 0.02 ] Ω -wire: R min = 0 kω Current input 4 20 m < 25 m 0 0 V < 7 m Electrical protection Short circuit proof and protected against reverse polarity Electrical connection/degree of protection Connector and junction box as per ISO 4400 (DIN 4650-, EN 750-80), IP 65) CE conformity (EMC) EMC Directive 2004/08/EC i See page 202 for prices. Options Fixed cable connection Other output signals Other connection threads SIL 2 (IEC 6508/65) 2-wire, for DMU 0 VM 200 Division II

Mechanical engineering DMU 0 Dimensions (mm) and electrical connections Connection G½B EN 87 Connection G¼B EN 87 DMU 0 VM with connection G½B DIN 852 type E with flush diaphragm DMU 0 VM B B Detail Flat gasket FKM (Viton) Wiring diagram Pin assignment table 2-wire 4 20 m Connector ISO 4400 Cable colours (DIN 4700) Supply - 2-wire system: (4 20 m) Supply Earth 2 Earth pin White Brown Yellow/green -wire 0 0 V Signal + -wire system: (0 0 V) Supply Signal + Earth 2 Earth pin White Brown Green Green/yellow The units are shipped with a detailed connection diagram. Division II 20

Mechanical engineering DMU 0 DG: H, PG: 4 Type DMU 0 K DMU 0 DMU 0 VM Version Measuring principle Piezo-resistive thick-film ceramic measuring cell Measuring accuracy (IEC 60770) % FSO 0.5 % FSO (-/0 bar % FSO) 0.5 % FSO Wetted parts Connection G¼B DIN 852 type E Ceramic/stainless steel 04/FKM G½B EN 87 G½ DIN 852 type E with flush diaphragm Supply voltage DC 8 2 V DC 8 2 V DC 8 2 V Output 4 20 m 4 20 m 4 20 m System 2-wire 2-wire 2-wire Electrical connection Connector and junction box as per ISO 4400 (DIN 4650-) Measuring range Part no. Part no. Part no. Price -/0 bar --- 4 69 -/+.5 bar 608 66 620 -/+ bar 609 67 62 -/+5 bar 60 68 622 Price 0/ bar --- 5 62 0/.6 bar 5 6 624 0/2.5 bar 52 7 625 0/4 bar 5 8 626 0/6 bar 54 9 627 0/0 bar 55 20 628 0/6 bar 56 2 629 0/25 bar 57 22 60 0/40 bar 58 2 --- 0/60 bar 6 24 --- 0/00 bar 62 25 --- Price 0/60 bar 6 26 --- 0/250 bar 64 27 --- 0/400 bar --- 28 --- 0/600 bar --- --- --- * Delivery only in packing units of 0 pieces per measuring range 202 Division II

Mechanical engineering Extra charges for pressure transducers DMU 0 DG: H Type DMU 0 DMU 0 VM Version Price Price Connection G½B DIN 852 type E --- Standard Connection G¼B EN 87 type E --- Connection ¼-8 NPT --- Connection ½-4 NPT --- Other connections On request On request Suitable for oxygen ( 25 bar) Fixed cable connection 2 metres Cable extension per metre Output 0 0 V, -wire Other output signals On request On request bsolute pressure (measuring ranges according to data sheet) SIL 2 (4 20 m only) --- i See chapter 8 for digital display units and signal processing. Division II 20

Process engineering DMU 02 Industrial version Extremely resistant to shock, pulsation and vibration High overload safety Dynamic pressure resistance at high load changes Wetted area without seals due to welding No transmission liquid Page 7 Page 72 Page 7 pplication Description For electronic pressure measurement in industrial applications, e.g. hydraulic, pneumatic, gas industry, refrigeration, automation, medical, as well as general mechanical and plant engineering applications. convert physical pressure into an electrical signal proportional to the pressure. DMU 02 is equipped with a piezo-resistive polysilicon thin-film measuring cell. Technical specifications Measuring accuracy Deviation from the characteristic curve according to IEC 60770 limit point calibration (non-linearity, hysteresis, repeatability): <±0.5 % FSO Measuring ranges Relative pressure: -/0 to -/+24 bar 0/0.6 to 0/2000 bar Overpressure safety 250 bar at least 2 x FS (burst pressure at least x FS) 250 bar at least.5 x FS (burst pressure at least 2 x FS),000 bar at least.2 x FS (burst pressure at least.5 x FS) Operating temperature range Medium: -40/+25 C mbient: -40/+05 C Storage: -40/+25 C Temperature error band In compensated range -20/+85 C 0.5 % FSO/0 K Dynamic characteristics Response time < ms Process connection G½B (EN 87-/7.) Material Housing: Stainless steel 04 Pressure connection: Stainless steel 60 Seal: Without Supply voltage DC 9 2 V EX version: DC 20 27 V Output signal 4 20 m, 2-wire 0 0 V, -wire Load UB 4 20 m UBmin 0.02 t least 00 Ohm with EX version 0 0 V > 5 kohm Current input 4 20 m < 25 m 0 0 V < 20 m Electrical protection Short circuit proof and protected against reverse polarity Electrical connection/degree of protection Connector and junction box as per ISO 4400 (DIN 4650-), IP 65 CE conformity (EMC) EMC Directive 2004/08/EC Options Other connection threads Fixed cable connection Other connectors Other output signals Cleaned for oxygen EX version (II G Ex ia IIB T4) i See page 209 for prices. 204 Division II

Process engineering DMU 02 Dimensions (mm) and electrical connections Connector ISO 4400 (DIN 4650-) M2 connector ( 56) 0.5 B EX version Connector DIN 4650-C Fixed cable connection Pin assignment table 2-wire system: Supply Earth -wire system: Supply - Signal Earth The units are shipped with a detailed connection diagram. ISO 4400 (DIN 4650-, EN 750-80) 2 Earth contact 2 Earth pin Electrical connections M 2 x (4-pin) EN 6076-2-0 4 Cable outlet Red Black Red Black White Division II 205

Process engineering DMU 02 Vario (programmable) Connection technology with numerous versions Extremely resistant to shock, pulsation and vibration Best dynamic pressure resistance at high load changes Measuring cell welded without seals Without transmission medium Turn Down :4 Zero correction via magnet Page 7 Page 72 Page 79 pplication Description For electronic pressure measurement in mechanical and plant engineering applications, gas applications and medical technology. Particularly suitable for pure media. convert physical pressure into an electrical signal proportional to the pressure. DMU 02 Vario is equipped with a piezo-resistive polysilicon thin-film measuring cell. ll standard electrical connection types are available. The measuring ranges can be changed via optional parameterisation hardware and software. The zero point can be corrected from the outside via a permanent magnet after voltage has been supplied and within a given time window. Technical specifications Measuring accuracy Deviation from the characteristic curve according to IEC 60770 limit point calibration (non-linearity, hysteresis, repeatability): <±0. % FSO Measuring ranges Relative pressure: -/0 to -/+24 bar 0/ bar to 0/,000 bar Overpressure safety 250 bar at least 2 x FS (burst pressure at least x FS) > 250 bar at least.5 x FS (burst pressure at least 2 x FS) 000 bar at least.2 x FS (burst pressure at least.5 x FS) Operating temperature range Medium: -40/+25 C mbient: -40/+05 C Storage: -40/+25 C Temperature error band In compensated range -0/+80 C < 0.5 % FSO/0 K Dynamic characteristics Response time < 4 ms (without flush diaphragm) Process connection G½B (EN 87-/7.) Material Housing: Stainless steel 04 Pressure connection: Stainless steel 60/6 Ti/6 L Seal: Without Supply voltage DC 9 2 V Output signal 4 20 m, 2-wire Load UB 4 20 m < UBmin 0.02 0 0 V > 5 kohm Current input < 25 m Electrical protection Short circuit proof and protected against reverse polarity Electrical connection/degree of protection Connector and junction box as per ISO 4400 (DIN 4650-), IP 65 CE conformity (EMC) EMC Directive 2004/08/EC i See page 208 for dimensions. See page 209 for prices. Options Other process connections Other electrical connections Field housing (stainless steel) Cleaned for oxygen Other output signals Fitting of chemical seal Customer-specific setting (damping, unit) Programmable hardware and software Other operating temperature ranges 206 Division II

Process engineering DMU 02 Vario (flush) Ideal for hygienic processes Connection technology with numerous versions Extremely resistant to shock, pulsation and vibration Best dynamic pressure resistance at high load changes Zero correction via magnet Page 7 Page 72 Page 7 pplication Description For electronic pressure measurement in mechanical and plant engineering applications, gas applications and medical technology. With flush diaphragm, the pressure transducers are also suitable for use with viscous, highly viscous or crystallising media. convert physical pressure into an electrical signal proportional to the pressure. DMU 02 Vario is equipped with a piezo-resistive polysilicon thin-film measuring cell. DMU 02 Vario is available in a virtually unlimited number of versions. ll standard and customer-specific connections can be connected to the electronic precision measuring system. ll standard electrical connection types are available. The zero point can be corrected from the outside via a permanent magnet after voltage has been supplied and within a given time window. Technical specifications Measuring accuracy Deviation from the characteristic curve according to IEC 60770 limit point calibration (non-linearity, hysteresis, repeatability): <±0. % FSO Measuring ranges Relative pressure: -/0 to -/+24 bar 0/ bar to 0/600 bar Overpressure safety 250 bar at least 2 x FS (burst pressure at least x FS) > 250 bar at least.5 x FS (burst pressure at least 2 x FS) Operating temperature range Medium: -0/+25 C mbient: -0/+05 C Storage: -0/+25 C Temperature error band In compensated range 0/70 C <.5 % FSO/0 K Dynamic characteristics Response time < 20 ms Process connection G½B DIN 852 with O ring (FBO); Clamp (CP); dairy fitting (MR); Varivent (VT); NEUMO BioControl (BC); Flange connection (FT) Material Housing: Stainless steel 04 Pressure connection: Stainless steel 6 L Seal: Without Pressure transmission liquid Multi-grade oil, FD-compliant Supply voltage DC 9 2 V Output signal 4 20 m, 2-wire Load UB 4 20 m < UBmin 0.02 Current input < 25 m Electrical protection Short circuit proof and protected against reverse polarity Electrical connection/degree of protection Connector and junction box as per ISO 4400 (DIN 4650-), IP 65 CE conformity (EMC) EMC Directive 2004/08/EC i See page 208 for dimensions. See page 209 for prices. Options Other process connections Other electrical connections Field housing (stainless steel) Filling for oxygen Other output signals Customer-specific setting (damping, unit) Division II 207

Process engineering DMU 02 Vario Dimensions (mm) and electrical connections Connection G½B EN 87 Wiring diagram 4 20 m, 2-wire Supply - 9 2 V DC Setting the zero point Magnet Modular system for great variety of versions Connector ISO 4400 Field housing M2 x M2 x with junction box Transducer electronics Thermal isolation Housing Direct mounting Cooling element up to 80 ºC Capillary Process connections Length = to 0 m Other lengths on request G½B EN 87 G½B DIN 852-E ½ 4 NPT VCR 9/6-8 UNF Chemical seals (e.g. MD 40) Spanner size SW 27 Sealing ring FKM SW 5/8 208 Division II

Process engineering DMU 02/DMU 02 Vario DG: H, PG: 4 Type DMU 02 DMU 02 HD High pressure DMU 02 Vario Programmable* DMU 02 Vario FBO flush with O ring DMU 02 Vario CP Clamp Version Measuring principle Measuring accuracy (IEC 60770) Wetted parts Piezo-resistive polysilicon stainless steel measuring cell (thin-film) 0.5 % FSO 0.5 % FSO 0. % FSO Stainless steel 60 Stainless steel 60 Stainless steel 60 Stainless steel 6 Ti/ FKM Stainless steel 6 L Connection G½B EN 87 M8 x.5 male G½B EN 87 G½B DIN 852- ISO 2852 " Supply voltage Output System Electrical connection DC 9 2 V 4 20 m 2-wire Connector and junction box as per ISO 4400 (DIN 4650-) Offset error compensation --- --- Subsequent zero correction via magnet from the outside Measuring range Part no. Part no. Part no. Part no. Part no. Price -/0 bar 280 --- 28 286 2892 -/-.5 bar 2802 --- 284 2864 289 -/+ bar 280 --- 285* 2865 2894 -/+5 bar 2804 --- 286 2866 2895 -/+9 bar 2805 --- 287* 2867 2896 -/+24 bar 2806 --- 288* 2868 2897 Price 0/600 mbar 2807 284 --- --- Price 0/ bar 2808 --- 2842* 2872 290 0/.6 bar 2809 --- 284 287 2902 0/2.5 bar 280 --- 2844* 2874 290 0/4 bar 28 --- 2845 2875 2904 0/6 bar 282 --- 2846 2876 2905 0/0 bar 28 --- 2847* 2877 2906 0/6 bar 284 --- 2848 2878 2907 0/25 bar 285 --- 2849 2879 2908 0/40 bar 286 --- 2850* 2880 2909 0/60 bar 287 --- 285 288 --- 0/00 bar 288 --- 2852 2882 --- Price 0/60 bar 289 --- 285* 288 --- 0/250 bar 2820 --- 2854 2884 --- 0/400 bar 282 --- 2855 2885 --- 0/600 bar 2822 --- 2856 2886 --- 0/,000 bar 282 --- 2857* --- --- 0/,600 bar --- 2829 --- --- --- 0/2,000 bar --- 280 --- --- --- * Programmable turn down :4 via optional programming tool (no asterisk = fixed measuring range) i See pages 2/22 for extra charges. Division II 209

Process engineering DMU 02 Vario DG: H, PG: 4 Type DMU 02 Vario CP Clamp DMU 02 Vario MR Dairy fitting DMU 02 Vario VT VRIVENT DMU 02 Vario BC NEUMO BioControl DMU 02 Vario FL Flange Version Measuring principle Measuring accuracy (IEC 60770) Wetted parts Stainless steel 6 L Piezo-resistive polysilicon stainless steel measuring cell (thin-film) Stainless steel 6 L Connection ISO 2852 ½" DIN 85 DN 25 0. % FSO Stainless steel 6 L VRIVENT F (DN 25 and ") Stainless steel 6 L NEUMO BioControl DN 25 Stainless steel 6 L EN 092- type B DN 25 PN 40 Supply voltage DC 9 2 V Output System Electrical connection 4 20 m 2-wire Connector and junction box as per ISO 4400 (DIN 4650-) Offset error compensation Subsequent zero correction via magnet from the outside Measuring range Part no. Part no. Part no. Part no. Part no. Price -/0 bar 080 295 298 2960 298 -/-.5 bar 08 296 299 296 2982 -/+ bar 082 297 2940 2962 298 -/+5 bar 08 298 294 296 2984 -/+9 bar 084 299 2942 2964 2985 -/+24 bar 085 2920 294 2965 2986 Price 0/ bar 089 2924 2947 2969 2990 0/.6 bar 090 2925 2948 2970 299 0/2.5 bar 09 2926 2949 297 2992 0/4 bar 092 2927 2950 2972 299 0/6 bar 09 2928 295 297 2994 0/0 bar 094 2929 2952 2974 2995 0/6 bar 095 290 295 2975 2996 0/25 bar 096 29 2954 --- 2997 0/40 bar 097 292 --- --- 2998 0/60 bar --- --- --- --- On request 0/00 bar --- --- --- --- On request 0/60 bar --- --- --- --- On request 0/250 bar --- --- --- --- On request i See pages 2/22 for extra charges. 20 Division II

Process engineering Extra charges for DMU 02/DMU 02 Vario DG: H Type DMU 02 DMU 02 HD High pressure DMU 02 Vario Programmable DMU 02 Vario FBO flush with O ring DMU 02 Vario CP Clamp Version Price Price Price Price Price EX protection II G Ex ia IIC T4 --- --- --- --- Connection G¼B EN 87 --- --- --- Connection G½B DIN 852 type E No extra charge --- No extra charge --- --- Connection G¼B DIN 852 type E --- --- --- Connection G½B DIN 852 type On request --- On request --- --- Connection G¼B DIN 852 type On request --- On request --- --- Connection ¼ 8 NPT --- --- --- Connection ½ 4 NPT --- --- --- High pressure connection M20 x.5 female --- No extra charge --- --- --- Connection G½B (flush DIN 852-) --- --- --- No extra charge --- Connection GB (flush DIN 852 ) --- --- --- No extra charge --- Connection GB (flush with O ring DIN 852 ) --- --- --- On request --- Connection clamp ISO 2852 2" --- --- --- --- Connection clamp ISO 2852 2½" --- --- --- --- Other connections and designs (chemical seals) --- --- See chapter 2. --- --- Other materials On request Coatings On request Surface roughness 0.4 µm --- --- --- Weld-in socket G½" --- --- --- --- Weld-in socket G" --- --- --- On request --- High temperature version up to 80 C --- Capillary tube with spiral hose --- --- See page 90. See page 90. See page 90. Cleaned for oxygen On request On request Socket DIN 4650-C No extra charge No extra charge --- --- --- Field housing (stainless steel) --- --- Circular connector M2x, 4-pin, -coded DIN-EN 6076-2-0 On request Fixed cable connection 2 metres --- --- --- Cable extension per metre --- --- --- Right angle socket M2 x.5 with 2 m PUR cable, shielded --- --- Right angle socket M2 x.5 with 5 m PUR cable, shielded --- --- Output 0 20 m, -wire --- --- --- Output 0 0 V, -wire --- --- --- CNopen 2.0 On request On request --- --- --- Ratiometric 0.5 4.5 V @ 5 VDC --- --- --- Other output signals On request On request On request On request On request Calibration report (for measuring accuracy up to 0. % FSO) Programming hardware and software for DMU 02 Vario --- --- --- --- Division II 2

Process engineering Extra charges for DMU 02/DMU 02 Vario DG: H Type DMU 02 Vario MR Dairy fitting DMU 02 Vario VT VRIVENT DMU 02 Vario BC NEUMO BioControl DMU 02 Vario FL Flange Version Price Price Price Price Connection DIN 85 DN 2 / PN 40 --- --- --- Connection DIN 85 DN 40 / PN 40* --- --- --- Connection DIN 85 DN 50 / PN 25* --- --- --- Connection DIN 85 DN 65 / PN 25 --- --- --- Connection DIN 85 DN 80 / PN 25 --- --- --- Connection VRIVENT type N DN 40-25 and ½" 6" --- --- --- NEUMO BioControl DN 50 --- --- --- NEUMO BioControl DN 65 --- --- --- NEUMO BioControl DN 80 --- --- --- Connection EN 092- type B DN 40 PN 40 --- --- --- Connection EN 092- type B DN 50 PN 40 --- --- --- Connection EN 092- type B DN 80 PN 40 --- --- --- Connection EN 092- type B DN 00 PN 40 --- --- --- Connection SME B 6.5 DN " class 50 --- --- --- Connection SME B 6.5 DN ½" class 50 --- --- --- Connection SME B 6.5 DN 2" class 50 --- --- --- Connection SME B 6.5 DN " class 50 --- --- --- Connection SME B 6.5 DN 4" class 50 --- --- --- Other connections and designs --- --- --- On request Other materials On request On request On request On request Coatings On request On request On request On request Surface roughness 0.4 µm High temperature version up to 80 C Capillary tube with spiral hose See page 90. P. 90 P. 90 P. 90 Cleaned for oxygen On request On request On request On request Field housing (stainless steel) Circular connector M2 x, 4-pin, -coded EN 6076-2-0 Right angle socket M2 x.5 with 2 m PUR cable, shielded Right angle socket M2 x.5 with 5 m PUR cable, shielded Other output signals On request On request On request On request 5-point calibration report (for measuring accuracy up to 0. % FSO) * See extra charges DMU 04 for sep. union nut. 22 Division II

Process engineering DMU 0 Industrial version For low pressure ranges Versions for relative pressure and absolute pressure Excellent long-term stability Optional TEX version Page 7 Page 72 Page 7 i See page 25 for prices. pplication Description Technical specifications Options For electronic pressure measurement in mechanical and plant engineering as well as process engineering applications. With flush diaphragm, the pressure transducers are also suitable for use with viscous, highly viscous media. convert physical pressure into an electrical signal proportional to the pressure. DMU 0 is equipped with an oil-filled piezo-resistive silicon measuring cell. DMU 0 has safety integrity level SIL 2 (IEC 6508/65). Measuring accuracy Deviation from the characteristic curve according to IEC 60770 limit point calibration (non-linearity, hysteresis, repeatability): < ± 0.5 % FSO (measuring ranges 0/00 mbar to 0/400 mbar ±0.5 % FSO) Long-term stability ±0. % FSO/year at reference conditions Measuring ranges Relative pressure: 0/00 mbar to 0/600 bar bsolute pressure: 0/400 mbar to 0/600 bar Overpressure safety t least x FS, except for 40 bar: Overload = 05 bar 400, 600 bar: Overload =,000 bar Burst pressure at least 5 x FS, except for 25 bar: Burst pressure = 20 bar 400 bar: Burst pressure =,250 bar 600 bar: Burst pressure =,800 bar Operating temperature range Medium: -40/+25 C mbient: -40/+85 C Storage: -40/+00 C Temperature error band PN < 0.4 bar ± % FSO in compensated range 0/70 C PN 0.4 bar to 40 bar ± 0.75 % FSO in compensated range -20/+85 C PN 60 bar to 600 bar ± 0.75 % FSO in compensated range 0/70 C Dynamic characteristics Response time 2-wire 0 ms -wire ms EX version (II G Ex ia IIC T4) Other process connections Other electrical connections Field housing (stainless steel 0) Other seal materials Process connection G½B (EN 87-/7.) / DIN 852-E with flush diaphragm (0/00 mbar to 0/40 bar) Materials Housing: Stainless steel 6 L Pressure connection: Stainless steel 6 L Diaphragm: Stainless steel 6 L Seal: FKM (Viton) Pressure transmission liquid Silicone oil Output signal/supply voltage 4 20 m, 2-wire DC 8 2 V TEX version DC 0 28 V 0 20 m, -wire DC 4 0 V 0 0 V, -wire DC 4 0 V Load 4 20 m: R max = [(U B U Bmin) / 0.02 ] Ω 0 20 m 500 Ω 0 0 V > 0 kω Current input 4 20 m < 25 m 0 20 m < 25 m 0 0 V < 7 m Electrical protection Short circuit proof and protected against reverse polarity Electrical connection/degree of protection Connector and junction box as per ISO 4400 (DIN 4650-), IP 65 CE conformity (EMC) EMC Directive 2004/08/EC Higher accuracy Greater overpressure safety Fitting of chemical seal SIL 2 (IEC 6508/65) 2-wire Division II 2

Process engineering DMU 0 Dimensions (mm) and electrical connections Connection G½B EN 87 and ISO 4400 Connection G¼B EN 87 and ISO 4400 Connection G½B DIN 852 type E with flush diaphragm B P N 0/00 mbar to 0/40 bar: Length of housing 50 mm P N 0/60 bar to 0/600 bar: Length of housing 59 mm EX version: Length of housing 8 mm DMU 0 with G½B EN 87 and field housing P N 0/00 mbar to 0/40 bar: Length of housing 50 mm P N 0/60 bar to 0/600 bar: Length of housing 59 mm EX version: Length of housing 8 mm Electrical connections ISO 4400 (DIN 4650) Binder 72 The Ex version is 26.5 mm longer. (cable gland M2 x.5 brass, nickel-plated) Wiring diagram 2-wire -wire 4 20 m 0 20 m 0 0 V Supply - Supply - Supply - Signal + Pin assignment table 2-wire system: (4 20 m) Supply Earth -wire system: Supply Signal + Earth Connector ISO 4400 (DIN 4650) 2 Earth pin 2 Earth pin Binder Series 72 4 5 4 5 Cable colours (DIN 4700) White Brown Yellow/ green White Brown Green Yellow/ green The units are shipped with a detailed connection diagram. 24 Division II

Process engineering DMU 0 DG: H, PG: 4 Type DMU 0 DMU 0 VM Version Measuring principle Measuring accuracy (IEC 60770) Wetted parts Connection Piezo-resistive stainless steel measuring cell 0.5 % FSO (< 0.4 bar 0.5 % FSO) G½B EN 87 0.5 % FSO (< 0.4 bar 0.5 % FSO) Stainless steel 6 L G½B DIN 852 type E with flush diaphragm Diaphragm Supply voltage DC 8 2 V DC 8 2 V Output 4 20 m 4 20 m System 2-wire 2-wire Electrical connection Connector and junction box as per ISO 4400 (DIN 4650-) Measuring range Part no. Part no. Price -/0 bar 64 --- -/+.5 bar 65 --- -/+ bar 66 --- -/+5 bar 67 --- Price 0/40 mbar --- --- 0/60 mbar --- --- 0/00 mbar 68 64 0/60 mbar 69 644 0/250 mbar 45 65 0/400 mbar 46 66 0/600 mbar 47 67 Price 0/ bar 48 68 0/.6 bar 49 69 0/2.5 bar 50 70 0/4 bar 5 7 0/6 bar 52 72 0/0 bar 5 7 0/6 bar 54 74 0/25 bar 55 75 0/40 bar 56 2026 0/60 bar 57 --- 0/00 bar 58 --- Price 0/60 bar 59 --- 0/250 bar 60 --- 0/400 bar 6 --- 0/600 bar 62 --- Division II 25

Process engineering Extra charges for pressure transducers DMU 0 DG: H Type DMU 0 DMU 0 VM Version Price Price EX protection II G Ex ia IIC T4 Connection G¼B DIN 852 type E --- Connection G½B DIN 852 type E No extra charge Standard Connection G¼B EN 87 type E --- Connection ¼-8 NPT --- Connection ½-4 NPT --- Other connections On request On request Field housing (stainless steel 0) Binder connector 72 Fixed cable connection 2 metres Cable extension per metre Output 0 20 m, -wire Output 0 0 V, -wire Other output signals On request On request bsolute pressure (measuring ranges according to data sheet) Measuring accuracy 0.25 % FSO 5-point calibration report (for measuring accuracy up to 0.25 % FSO) Fitting of chemical seal SIL 2 (4 20 m only) ll measuring ranges, minimum range depends on design of chemical seal --- i See chapter 8 for digital display units and signal processing. i See chapter 2 for chemical seals. 26 Division II

Process engineering DMU 04 industrial version DMU 04 CP/MR for hygienic processes Small temperature error Optional: TEX, field housing or high temperature version (up to 00 C) Page 7 Page 72 Page 7 pplication Description For applications requiring hygienic process connections, materials or processing, especially food technology, pharmaceutical and biotechnology applications. convert physical pressure into an electrical signal proportional to the pressure. DMU 04 is equipped with an oil-filled piezo-resistive silicon measuring cell. DMU 04 has safety integrity level SIL 2 (IEC 6508/65). Technical specifications Measuring accuracy Deviation from the characteristic curve according to IEC 60770 limit point calibration (non-linearity, hysteresis, repeatability): < ± 0.5 % FSO (measuring ranges 0/400 mbar and > 40 bar < ±0.5 % FSO) Measuring ranges Relative pressure: -/0 bar, 0/00 mbar to 0/40 bar bsolute pressure: 0/400 mbar to 0/400 bar Overpressure safety t least x FS, except for 40 bar: Overload = 05 bar (burst pressure at least 5 x FS), except for 25 bar: Burst pressure = 20 bar Operating temperature range Medium: -0/+25 C Short-term (60 min) up to 50 C mbient: -40/+85 C Storage: -40/+00 C Temperature error band In compensated range -20/+85 C ± 0.75 % FSO/0 K (0 50 C < 0.40 bar ±.5 % FSO/0 K) Dynamic characteristics Response time 2-wire 0 ms -wire ms Process connections G½B DIN 852 with flush diaphragm, GB DIN 852 with flush diaphragm Clamp "/½"/2" ISO 2852, Conical dairy fitting DIN 85 DN 25/40/50 (without union nut) Materials Housing: Stainless steel 6 L Pressure connection: Stainless steel 6 L Diaphragm: Stainless steel 6 L Pressure transmission liquid Food oil (FD-compliant) Output signal/supply voltage 4 20 m, 2-wire DC 8 2 V EX version DC 0 28 V 0 20 m, -wire DC 4 0 V 0 0 V, 2-wire DC 4 0 V Load 4 20 m: R max = [(U B U Bmin) / 0.02 ] Ω 0 20 m 500 Ω 0 0 V > 0 kω Current input 4 20 m < 25 m 0 20 m < 25 m 0 0 V < 7 m Electrical protection Short circuit proof and protected against reverse polarity Electrical connection/degree of protection Connector and junction box as per ISO 4400 (DIN 4650-), IP 65 CE conformity (EMC) EMC Directive 2004/08/EC i See page 22 for prices. Options EX version (II G Ex ia IIC T4) Other process connections Other electrical connections Field housing (stainless steel 0) High temperature version up to 00 C Higher accuracy Union nut DN 25/40/50 SIL 2 (IEC 6508/65) 2-wire Division II 27

Hygienic processes DMU 04 Dimensions (mm) and electrical connections Threaded connections with flush diaphragm Clamp connection ISO 2852 GB G½B The SIL and EX versions are 26.5 mm longer. Clamp " Conical dairy fitting DIN 85 Field housing Conical dairy fitting DN 25 Wiring diagram Pin assignment table 2-wire 4 20 m Connector ISO 4400 (DIN 4650) Cable colours (DIN 4700) -wire Supply - 2-wire system: (4 20 m) Supply Earth 2 Earth pin White Brown Yellow/green 0 20 m Supply - -wire system: (0 0 V) Supply (0 20 m) Signal + Earth 2 Earth pin White Brown Green Yellow/green 0 0 V Supply - Signal + The units are shipped with a detailed connection diagram. 28 Division II

Process engineering DMU 05 P precision version Precision version with outstanding measurement performance For applications requiring superior measuring accuracy and long-term stability Optional RS 485 Modbus RTU and TEX versions Page 7 Page 72 Page 7 pplication Description For electronic pressure measurement in applications requiring high measuring accuracy and long-term stability, such as process engineering, water treatment, laboratory applications as well as measurements of gas consumption and heat energy. convert physical pressure into an electrical signal proportional to the pressure. DMU 05 P is equipped with an oil-filled piezo-resistive silicon measuring cell. The intelligent DMU 05 pressure transducers are equipped with digital amplifier electronics (microprocessor and 6 bit /D converter). DMU 05 P actively compensates for sensor-specific deviations (non-linearity and temperature error), allowing for superior measuring characteristics. DMU 05 can also be supplied with optional digital RS 485 Modbus RTU for setting offset, range and damping. Technical specifications Measuring accuracy Deviation from the characteristic curve according to IEC 60770 limit point calibration (non-linearity, hysteresis, repeatability): < ± 0. % FSO Long-term stability +0. % FSO/year Measuring ranges Relative pressure: 0/400 mbar to 0/600 bar bsolute pressure: 0/400 mbar to 0/600 bar Overpressure safety t least 2 x FS, 600 bar at least.5 x FS (burst pressure at least 5 x FS, 400 bar at least 2 x FS) Operating temperature range Medium: -25/+25 C mbient: -25/+85 C Storage: -40/+00 C Temperature error band In compensated range -20/+80 C 0.02 % FSO/0 K Dynamic characteristics Response time < 5 ms Process connection G½B (EN 87-/7.) or G½ DIN 852 type E with flush diaphragm (0/400 mbar to 0/40 bar) Materials Housing: Stainless steel 6 L Pressure connection: Stainless steel 6 L Diaphragm: Stainless steel 6 L Seal: FKM (Viton) Pressure transmission liquid Silicone oil Output signal/ supply voltage 4 20 m DC 2 6 V 2-wire EX version DC 4 28 V Load 4 20 m: R max = [(U B U Bmin) / 0.02 ] Ω Current input 4 20 m < 25 m Electrical protection Short circuit proof and protected against reverse polarity Electrical connection/degree of protection Connector and junction box as per ISO 4400 (DIN 4650-), IP 65 CE conformity (EMC) EMC Directive 2004/80/EC i See page 22 for prices. Options RS 485 Modbus RTU in conjunction with Binder connector 72, 5-pin or cable output (interface and software required) EX version (II G Ex ia IIC T4) Other process connections Other electrical connections Other seal materials Division II 29

Process engineering DMU 05 P Dimensions (mm) and electrical connections Connection G½B EN 87 Connection G½B DIN 852 type E with flush diaphragm 400 400 00 22 0 G½B EX version 6 mm G¾B DIN 852 type E Screw-in version for level measurement Electrical connections / cable outlet ISO 4400 (DIN 4650-) Binder 72 (5-pin) 82 6 Cable outlet with PVC cable Wiring diagram 2-wire 4 20 m RS 485 Supply - Pin assignment table 2-wire system: Supply Earth Digital signal supply + RS 485: GND Pin Pin B Earth ISO 4400 (DIN 4650) 2 Earth contact The units are shipped with a detailed connection diagram. Electrical connections Binder 72 (5-pin) 4 5 4 2 5 Cable outlet White Brown Yellow/green White Brown Yellow Pink Yellow/green 220 Division II

Process engineering DMU 04/DMU 05 P DG: H, PG: 4 Type DMU 04 DMU 04 DMU 04 CP DMU 04 MR DMU 05 P DMU 05 P VM Version Measuring principle Measuring accuracy (IEC 60770) 0.5 % FSO (< 0.4 bar 0.5 % FSO > 40 bar 0.5 % FSO) 0.5 % FSO (< 0.4 bar 0.5 % FSO > 40 bar 0.5 % FSO) Piezo-resistive stainless steel measuring cell 0.5 % FSO (< 0.4 bar 0.5 % FSO) 0.5 % FSO (< 0.4 bar 0.5 % FSO) 0. % FSO 0. % FSO Wetted parts Stainless steel 6 L/FKM Stainless steel 6 L/FKM Connection G½B DIN 852-E with flush diaphragm GB DIN 852-E with flush diaphragm Clamp " ISO 2852 Conical dairy fitting DIN 85 DN 25 (without union nut) G½B EN 87 G½B DIN 852 with flush diaphragm Supply voltage DC 8 2 V DC 8 2 V DC 8 2 V DC 8 2 V DC 2 6 V DC 2 6 V Output 4 20 m 4 20 m 4 20 m 4 20 m 4 20 m 4 20 m System 2-wire 2-wire 2-wire 2-wire 2-wire 2-wire Electrical connection Connector and junction box as per ISO 4400 (DIN 4650-) Measuring range Part no. Part no. Part no. Part no. Part no. Part no. Price -/0 bar --- 66 686 79 742 --- -/+.5 bar 647 664 687 720 74 --- -/+ bar 648 665 688 72 744 --- -/+5 bar 649 666 689 722 745 --- Price 0/00 mbar --- 02 --- --- 026 027 0/60 mbar --- 022 --- --- 747 77 0/250 mbar 06 669 02 025 748 772 0/400 mbar 07 670 024 726 749 77 0/600 mbar 08 67 694 727 750 774 Price 0/ bar 09 672 695 728 75 775 0/.6 bar 020 67 696 729 752 776 0/2.5 bar 65 674 697 70 75 777 0/4 bar 652 675 698 7 754 778 0/6 bar 65 676 699 72 755 779 0/0 bar 654 677 70 7 756 780 0/6 bar 655 678 7 74 757 78 0/25 bar 656 679 --- 75 758 782 Price 0/40 bar 657 680 --- 76 759 028 0/60 bar 658 68 --- --- 760 --- 0/00 bar 659 682 --- --- 76 --- 0/60 bar 660 68 --- --- 762 --- 0/250 bar 66 684 --- --- 76 --- 0/400 bar 662 685 --- --- 764 --- 0/600 bar --- --- --- --- 765 --- Division II 22

Process engineering Extra charges for DMU 04/DMU 05 P DG: H Type DMU 04 DMU 04 DMU 04 CP DMU 04 MR DMU 05 P DMU 05P VM Version Price Price Price Price Price Price EX protection II G Ex ia IIC T4 Clamp ½" ISO 2852 --- --- No extra charge --- --- --- Clamp 2" ISO 2852 --- --- --- --- --- Conical dairy fitting DIN 85 DN 40 --- --- --- --- --- Conical dairy fitting DIN 85 DN 50 --- --- --- --- --- Sep. union nut DIN 85 DN 25 --- --- --- --- --- Sep. union nut DIN 85 DN 40 --- --- --- --- --- Sep. union nut DIN 85 DN 50 --- --- --- --- --- GB with conical seal --- --- --- --- --- Other process connections On request On request On request On request On request On request High temperature version up to +00 C --- --- Field housing (stainless steel 0) --- --- Binder connector 72, 5-pin Fixed cable connection 2 metres Cable extension per metre Output 0 20 m, -wire --- --- Output 0 0 V, -wire --- --- Other output signals On request On request On request On request On request On request bsolute pressure (measuring ranges according to data sheet) Measuring accuracy 0.25 % FSO --- --- 5-point calibration report (for measuring accuracy up to 0.25 % FSO) --- --- RS 485 Modbus RTU --- --- --- --- Programming interface and software --- --- --- --- On request On request SIL 2 (4 20 m only) --- --- i See chapter 8 for digital display units and signal processing. 222 Division II

Process engineering HydroFox DMU 07 for level measurement Flush diaphragm Without transmission liquid Mechanically insensitive ceramic sensor Small temperature error High overpressure safety Digital display unit D 2 Signalling device Page 7 Page 72 Page 7 Pressure transducer HydroFox DMU 07 pplication Description For continuous electronic level measurement of liquids and for pressure measurement of liquids and gases in plant engineering. convert physical pressure into an electrical signal proportional to the pressure. HydroFox DMU 07 uses a capacitance ceramic measuring cell. Technical specifications Measuring accuracy Deviation from the characteristic curve according to IEC 60770 limit point calibration (non-linearity, hysteresis, repeatability): <±0.5 % FSO Measuring ranges Relative pressure: 0/40 mbar to 0/20 bar Overpressure safety 400 mbar at least 5 x FS > 400 mbar at least x FS 6 bar at least 2 x FS Operating temperature range Medium: -40/+25 C mbient: -40/+85 C Storage: -40/+00 C Temperature error band In compensated range -20/+80 C 0. % FSO/0 K Dynamic characteristics Response time 200 ms Process connection G½B flush diaphragm Materials Housing: Stainless steel 6 L Pressure connection: Stainless steel 6 L Diaphragm: Ceramic (I 2O 96 %) Seal: FKM (Viton) Output signal/supply voltage 4 20 m DC 9 2 V 2-wire Load 4 20 m: R max = [(U B U Bmin) / 0.02 ] Ω 0 0 V R min = 0 kω Current input 4 20 m < 2 m Electrical protection Short circuit proof and protected against reverse polarity Electrical connection/degree of protection Connector and junction box as per ISO 4400 (DIN 4650-), IP 65 CE conformity (EMC) EMC Directive 2004/08/EC Options Pressure connection made of PVDF Other seal materials Field housing (stainless steel 0) Higher accuracy Other output signals i See chapter 5 for the complete "Level Measurement" range. See page 25 for prices. Division II 22

Process engineering HydroFox DMU 07 Dimensions (mm) and electrical connections Connection G½B DIN 852 type E connector and junction box ISO 4400 Pressure connection made of stainless steel Connection G½B field housing M 2 x.5 Cable outlet G½B Connection G½B DIN 852 type E connector and junction box ISO 4400 Pressure connection made of PVDF Electrical connections DIN 4650 Binder 72 Wiring diagram Pin assignment table 2-wire 4 20 m Electrical connections Connector ISO 4400 Binder 72 5-pin Cable colours (DIN 4700) -wire 0 0 V Supply - Supply - Signal + 2-wire system: (4 20 m) Supply Earth -wire system: (0 0 V) Supply (0 20 m) Signal + Earth 2 Earth pin 2 Earth pin 4 5 4 5 White Brown Yellow/ green White Brown Green Yellow/ green The units are shipped with a detailed connection diagram. 224 Division II

Process engineering HydroFox DMU 08 level probe Compact and sturdy stainless steel design Integrated overvoltage protection Special calibration for all standard pressure units possible Optional TEX version Junction box with pressure relief port Digital display unit D 2 Signalling device Page 74 Page 76 Page 80 Hydro Fox DMU 08 pplication Description For electronic, continuous level measurement, e.g. in wells, drilling holes, water, containers or in waste water systems. Suitable for groundwater, waste water (with optional FEP cable), diesel fuel and fuel oil. HydroFox DMU 08 convert physical pressure into an electrical signal proportional to the pressure. HydroFox DMU 08 uses a piezo-resistive silicon measuring cell. Technical specifications Measuring accuracy Deviation from the characteristic curve according to IEC 60770 limit point calibration (non-linearity, hysteresis, repeatability): <±0.5 % FSO (measuring ranges 0/00 mbar to 0/400 mbar < ±0.5 % FSO) Measuring ranges Relative pressure: 0/00 mbar to 0/25 bar Overpressure safety Overpressure safety See page 226. Operating temperature range Medium: -0/+70 C mbient: -0/+70 C Storage: -25/+70 C For EX version -20/+60 C at P atm 0.8 to. bar Temperature error band In compensated range 0/70 C 400 mbar ± % FSO/0 K 400 mbar ± 0.75 % FSO/0 K Dynamic characteristics Response time 0 ms Materials Housing: Stainless steel 6 L Diaphragm: Stainless steel 6 L Seals: FKM (Viton) Pressure transmission liquid Silicone oil Supply voltage DC 8 2 V EX version DC 0 28 V Output signal 4 20 m, 2-wire Load 4 20 m: R max = [(U B U Bmin) / 0.02 ] Ω Current input 4 20 m < 25 m Electrical protection Short circuit proof and protected against reverse polarity Electrical connection (degree of protection) PUR cable (IP 68) With integrated breather tube for reference to the ambient atmospheric pressure ccessories (options) Screw connector kit Junction box nchor clamp Extended weight i See chapter 5 for the complete "Level Measurement" range. Options See page 25 for prices. EX version (II G Ex ia IIC T4 Ga, II D Ex ia IIIC T 85 C Da) Measuring accuracy 0. % FSO FEP cable SIL 2 (IEC 6508/65) Division II 225

Process engineering HydroFox DMU 08 Dimensions (mm) and electrical connections Standard version EX version, SIL, -wire 0 0 V, accuracy 0. % FSO 5 ccuracy 0. % FSO 50 mm Ø 26.5 Screw connector kit nchor clamp Junction box with pressure relief port 2 PG Cable diameter Earth 2 Cable gland Pressure compensation element Wiring diagram Pin assignment table 2-wire 4 20 m Cable colours (DIN 4700) -wire 0 0 V Supply - Supply - Signal + 2-wire system: (4 20 m) Supply Earth -wire system: (0 0 V) (0 20 m) Supply Signal + Earth White Brown Yellow/green White Brown Green Yellow/green The units are shipped with a detailed connection diagram. Overpressure safety DMU 08 Measuring range 00 mbar 60 mbar 200 mbar 250 mbar 00 mbar 400 mbar 600 mbar bar.6 bar 2 bar 2.5 bar 4 bar 6 bar 0 bar 6 bar 20 bar 25 bar Overload 5 x 6 x 4 x 4 x 4 x 5 x 8 x 5 x 6 x 4 x 4 x 5 x 6 x 4 x 5 x x x Burst pressure 5 x 9 x 6 x 6 x 6 x 7 x 2 x 7 x 9 x 6 x 6 x 6 x 8 x 5 x 7 x 4 x 4 x 226 Division II

Process engineering HydroFox DMU 08 T level probe With integrated temperature measurement Compact and sturdy stainless steel design Integrated overvoltage protection Special calibration for all standard pressure units possible Page 7 Page 74 Page 80 pplication Description For electronic, continuous level and temperature measurement, e.g. in wells, drilling holes and for monitoring of rain overflow facilities, rivers and waters, for drinking water treatment in tanks or waste water systems. Suitable for groundwater, drinking water, waste water (with optional FEP cable), diesel fuel and fuel oil. HydroFox DMU 08 convert physical pressure and temperature into two independent, electrical signals. HydroFox DMU 08 uses a piezo-resistive silicon measuring cell; the temperature is measured by means of an integrated Pt 00 sensor. Technical specifications Measuring accuracy Deviation from the characteristic curve according to IEC 60770 limit point calibration (non-linearity, hysteresis, repeatability): <±0.5 % FSO (measuring ranges 0/00 mbar to 0/400 mbar < ±0.5 % FSO) Measuring ranges Relative pressure: 0/00 mbar to 0/25 bar Temperature (please specify when ordering):.) 0 0 C (designation: 000) 2.) 0 50 C (designation: 0050).) 0 70 C (designation: 0070) Overpressure safety See page 228. Operating temperature range Medium: -0/+70 C mbient: -0/+70 C Storage: -25/+70 C Temperature error band In compensated range 0/70 C < 400 mbar ± % FSO/0 K 400 mbar ± 0.75 % FSO/0 K Dynamic characteristics Response time 0 ms for output signal pressure Materials Housing: Stainless steel 6 L Diaphragm: Stainless steel 6 L Seals: FKM (Viton) Pressure transmission liquid Silicone oil Supply voltage Pressure: DC 0 0 V Temperature: DC 0 0 V Output signals Pressure: 4 20 m, 2-wire Temperature: 4 20 m, 2-wire Load 4 20 m: R max = [(U B U Bmin) / 0.02 ] Ω Current input 4 20 m < 25 m Electrical protection Short circuit proof and protected against reverse polarity Electrical connection (degree of protection) PUR cable (IP 68) With integrated breather tube for reference to the ambient atmospheric pressure ccessories (options) Screw connector kit Junction box nchor clamp Extended weight Options i See chapter 5 for the complete "Level Measurement" range. See page 25 for prices. FEP cable Other measuring ranges on request Division II 227

HydroFox DMU 08 T Dimensions (mm) and electrical connections Standard version Screw connector kit nchor clamp Junction box with pressure relief port 2 PG Cable diameter Earth 2 Cable gland Pressure compensation element Wiring diagram Pin assignment table 2-wire 4 20 m Supply - Electrical connections Supply P+ Supply P Supply T+ Supply T Earth Cable colours (DIN 4700) White Brown Grey Pink Yellow/green The units are shipped with a detailed connection diagram. Overpressure safety DMU 08 T Measuring range 00 mbar 60 mbar 200 mbar 250 mbar 00 mbar 400 mbar 600 mbar bar.6 bar 2 bar 2.5 bar 4 bar 6 bar 0 bar 6 bar 20 bar 25 bar Overload 5 x 6 x 4 x 4 x 4 x 5 x 8 x 5 x 6 x 4 x 4 x 5 x 6 x 4 x 5 x x x Burst pressure 5 x 9 x 6 x 6 x 6 x 7 x 2 x 7 x 9 x 6 x 6 x 6 x 8 x 5 x 7 x 4 x 4 x 228 Division II

Process engineering HydroFox DMU 09 Level probe for chemical applications Chemical-resistant plastic version Robust ceramic diaphragm without transmission liquid Highly resistant FEP cable Special calibration for all standard pressure units possible Junction box with pressure relief port Digital display unit D 2 Signalling device Page 7 Page 76 Page 80 Hydro Fox DMU 09 pplication Description For electronic, continuous level measurement in extremely corrosive liquids, e.g. chemicals or waste water from landfill sites. HydroFox convert physical pressure into an electrical signal proportional to the pressure. HydroFox DMU 09 uses a capacitance ceramic measuring cell. Technical specifications Measuring accuracy Deviation from the characteristic curve according to IEC 60770 limit point calibration (non-linearity, hysteresis, repeatability): <±0.5 % FSO Measuring ranges Relative pressure: 0/40 mbar to 0/0 bar Overpressure safety 400 mbar at least 5 x FS > 400 mbar at least x FS Operating temperature range Medium: -25/00 C mbient: -25/00 C Storage: -25/00 C Temperature error band In compensated range 0/70 C ± 0. % FSO/0 K Dynamic characteristics Response time < 200 ms Materials Housing: PP Diaphragm: Ultra-pure ceramic (l 2O 99.9 %) Seals: FKM (Viton) Output signal/supply voltage 4 20 m DC 9 2 V 2-wire Load 4 20 m: R max = [(U B U Bmin) / 0.02 ] Ω Current input 4 20 m < 2 m Electrical protection Short circuit proof and protected against reverse polarity Electrical connection/degree of protection FEP cable (IP 68) With integrated breather tube for reference to the ambient atmospheric pressure CE conformity (EMC) EMC Directive 2004/08/EC ccessories (options) Screw connector kit Junction box nchor clamp Options Housing PVDF Cable protection conduits FFKM seals i See chapter 5 for the complete "Level Measurement" range. See page 25 for prices. Division II 229

Process engineering HydroFox DMU 09 Dimensions (mm) and electrical connections Standard version Screw connector kit nchor clamp Junction box with pressure relief port 2 PG Cable diameter Earth 2 Cable gland PG Pressure compensation element Wiring diagram Pin assignment table 2-wire 4 20 m 2-wire system: (4 20 m) Supply Earth Cable colours (DIN 4700) White Brown Yellow/green Supply - The units are shipped with a detailed connection diagram. 20 Division II

Process engineering DeltaFox DMU 0 D Version for differential pressure measurement Compact design Robust aluminium housing High long-term stability High overpressure safety Long service life DeltaFox DMU 0 D P Digital display unit D 4 P2 Filter change Page 72 Page 7 Page 80 Filters pplication Description For electronic differential pressure measurement at very low differential pressure. For non-corrosive gaseous media. Particularly suitable for monitoring filters and fans in air and air conditioning applications. The DeltaFox DMU 0 D pressure transducers feature piezo-resistive silicon measuring cells. When pressure is applied, the pressure difference between the positive side and the negative side is converted into a current or voltage signal which is proportional to the differential pressure. i See page 25 for prices. Technical specifications Measuring accuracy Deviation from the characteristic curve as per IEC 60770 limit point calibration (non-linearity, hysteresis, repeatability): > 0/60 mbar: < ±0.5 % FSO 0/40 0/60 mbar: ± % FSO < 0/40 mbar: ±2 % FSO Long-term stability +0.2 % FSO/year Measuring ranges Differential pressure measuring range Overload 0/6 mbar to 0/0 mbar 00 mbar 0/25 mbar 200 mbar 0/40 mbar to 0/60 mbar 50 mbar 0/00 mbar to 0/400 mbar 000 mbar 0/600 mbar to 0/000 mbar 000 mbar Operating temperature range Medium: -25/+25 C mbient: -25/+85 C Storage: -40/+00 C Temperature error band Differential pressure measuring range 0/0 mbar 0/25 mbar 0/250 mbar Dynamic characteristics Response time < 5 ms In compensated range 0/60 C ±2 % FSO/0 K ±.5 % FSO/0 K ± % FSO/0 K > 0/250 mbar ±0.5 % FSO/0 K Process connection 2 x G /8B female thread Materials Housing: Other process connections Other electrical connections Digital plug-in display D 06 luminium, silver-coloured, anodised Process connection: luminium Sensor: Silicon, glass, RTV, Ceramic (l 2O ), nickel Seal: PUR glued Output signal / supply voltage 4 20 m, 2-wire DC 8 2 V 0 20 m, -wire DC 4 0 V 0 0 V, -wire DC 4 0 V Load 4 20 m: R max = [(U B U Bmin) / 0.02 ] Ω 0 20 m < 500 Ω 0 0 V > 0 kω Current input 0/4 20 m max. 25 m 0 0 V max. 7 m Electrical protection Short circuit proof and protected against reverse polarity Electrical connection/degree of protection Connector and junction box as per ISO 4400 (DIN 4650-), IP 65 CE conformity (EMC) EMC Directive 2004/08/EC Options Division II 2

Process engineering DeltaFox DMU 0 D Dimensions (mm) and electrical connections Connection 2 x G / 8 female thread ISO 4400 M4x0 B B Connector ISO 4400 Screw DMU 0 D with plug-in display D 06 Electrical connections Optional ISO 4400 Standard Optional B Connector ISO 4400 ISO 4400 (IP 65) M2x 4-pin (IP 67) Cable outlet (IP 67) Wiring diagram Pin assignment table 2-wire 4 20 m Pin assignment ISO 4400 (DIN 4650) M 2 x Cable colours -wire 0 20 m Supply - 2-wire system: (4 20 m) Supply Earth 2 Earth pin 2 4 White Brown Yellow/ green 0 0 V Supply - Supply - Signal + -wire system: Supply Signal + Earth 2 Earth pin 2 4 White Brown Green Yellow/ green 22 Division II

Process engineering DeltaFox DMU D Version for differential pressure measurement Compact design High overload safety Mechanically robust and reliable, suitable for applications involving dynamic pressure changes as well as shock and vibration P Delta Fox DMU D P2 Digital display unit D 2 Pump Page 72 Page 7 Page 80 pplication Description For electronic differential pressure measurement in industrial applications. For corrosive gaseous and liquid media which are not highly viscous and do not crystallise. The DeltaFox DMU D pressure transducers feature two oil-immersed piezo-resistive stainless steel measuring cells. When pressure is applied, the pressure difference between the positive side and the negative side is converted into a current or voltage signal which is proportional to the differential pressure. Technical specifications Measuring accuracy Deviation from characteristic curve as per IEC 60770 limit point calibration, non-linearity, hysteresis, reproducible): ± 0.5 % FSO (differential pressure range with turn-down from : to :5) ± % FSO (differential pressure range with turn-down from :5 to :0) Measuring ranges/overload safety Nominal pressure (bar) Differential pressure measuring range (bar) Max. static pressure at one end (bar) 0.2 0/0.02 to 0/0.2 0.5 0.4 0/0.04 to 0/0.4.0 0/0. to 0/.0 2.5 0/0.25 to 0/2.5 6 6.0 0/0.6 to 0/6.0 20 6 0/.6 to 0/6 60 Operating temperature range Medium: -25/+25 C mbient: -25/+85 C Storage: -40/+00 C Temperature error band In compensated range 0/70 C.5 % FSO/0 K In compensated range 0/50 C at nominal pressure 0.4 bar 2 % FSO/0 K In compensated range 0/50 C at nominal pressure 0.2 bar 2.5 % FSO/0 K Dynamic characteristics Response time < 5 ms Process connection 2 x G½B (87-/7.) Materials Housing: luminium, black, anodised Pressure connection: Stainless steel 6 L Diaphragm: Stainless steel 6 L Seal: FKM (Viton) Output signal / supply voltage 4 20 m, 2-wire DC 2 6 V 0 0 V, -wire DC 4-6 V Load 4 20 m: R max = [(U B U Bmin) / 0.02 ] Ω 0 0 V > 0 kω Current input 4 20 m < 25 m 0 0 V < 7 m Electrical protection Short circuit proof and protected against reverse polarity Electrical connection/degree of protection Connector and junction box as per ISO 4400 (DIN 4650-), IP 65 CE conformity (EMC) EMC Directive 2004/08/EC Scope of delivery Pressure measuring instrument with mounting bracket 4 Options i See page 25 for prices. Other process connections Other electrical connections Other seal materials Other output signals Fitting of chemical seal Delta Fox DMU D 2 Filter larm signal filter change 4 Digital display unit D 2 2 Division II 2

Process engineering DeltaFox DMU D Dimensions (mm) and electrical connections Connection 2 x G½B (EN 87) Connection 2 x G½B (EN 87) ISO 4400 M4 x 0 Connector Connection 2 x 7 / 6 UNF Screw Connection 2 x G¼ female thread ISO 4400 ISO 4400 (DIN 6450) G¼ 2 40 48 88 Spanner size SW 22 22.5 22.5 2 G¼ Connector Wiring diagram Connector 2 Pressure connection (female thread) Pin assignment table 2-wire 4 20 m Pin assignment ISO 4400 (DIN 4650) -wire 0 0 V Supply - Supply - Signal + 2-wire system: (4 20 m) Supply Earth -wire system: Supply (0...0 V) Signal + Earth 2 Earth pin 2 Earth pin The units are shipped with a detailed connection diagram. 24 Division II

Process engineering DMU 07 DMU D DG: H, PG: 4 Type DMU 07 DMU 07 FG DMU 08 DMU 08 T** DMU 09 DMU 0 D DMU D* Version Measuring principle Measuring accuracy (IEC 60770) Wetted parts Connection Capacitance ceramic measuring cell 0.5 % FSO 0.5 % FSO Ceramic/FKM Stainless steel 6 L G½B with flush diaphragm Ceramic/FKM Stainless steel 6 L G½B with flush diaphragm Piezo-resistive stainless steel measuring cell 0.5 % FSO ( 0.4 bar 0.5 % FSO) Stainless steel/ FKM 6 L Piezo-resistive stainless steel measuring cell 0.5 % FSO ( 0.4 bar 0.5 % FSO) Stainless steel/ FKM 6 L Piezo-resistive ceramic measuring cell 0.5 % FSO PP/ceramic/ FKM --- --- --- Piezo-resistive silicon measuring cell > 60 mbar = 0.5 % FSO 40 60 mbar = % FSO < 40 mbar = 2 % FSO luminium/silicon/glass RTV/ceramic, nickel/pur (glued) 2 x G / 8B female thread Piezo-resistive stainless steel measuring cell 0.5 % FSO (with ref. to nominal pressure) Stainless steel/ FKM 6 Ti 2 x G½B EN 87 Supply voltage DC 9 2 V DC 9 2 V DC 8 2 V DC 0 0 V DC 9 2 V DC 8 2 V DC 2 6 V Output 4 20 m 4 20 m 4 20 m 4 20 m 4 20 m 4 20 m 4 20 m System 2-wire 2-wire 2-wire 2-wire 2-wire 2-wire 2-wire Electrical connection Connector ISO 4400 (4650-) Field housing M2 x.5 5 m PUR cable 5 m PUR cable 5 m FEP cable Connector ISO 4400 (4650-) Measuring range Part no. Part no. Part no. Part no. Part no. Part no. Part no. Price 0/6 mbar --- --- --- --- --- 86 --- 0/0 mbar --- --- --- --- --- 862 --- 0/25 mbar --- --- --- --- --- 86 --- 0/40 mbar 789 82 --- --- 767 864 80 0/60 mbar 790 805 --- --- 768 865 8 0/00 mbar 79 547 555 555T0070 57 866 8 0/60 mbar 792 806 556 556T0070 572 867 84 0/200 mbar 79 548 557 557T0070 57 --- --- 0/250 mbar 794 807 558 558T0070 574 868 85 0/00 mbar --- --- 59 59T0070 82 --- --- 0/400 mbar 795 549 559 559T0070 575 869 82 0/600 mbar 796 808 560 560T0070 576 870 8 0/ bar 797 550 56 56T0070 577 87 86 0/.6 bar 798 809 562 562T0070 578 --- 84 0/2 bar 799 55 56 56T0070 579 --- --- 0/2.5 bar --- --- 564 564T0070 580 --- 87 0/4 bar 800 552 565 565T0070 58 --- 85 0/6 bar 80 80 566 566T0070 582 --- 88 0/0 bar 802 55 567 567T0070 58 --- 86 0/6 bar --- --- 568 568T0070 --- --- 87 0/20 bar --- --- 569 569T0070 --- --- --- 0/25 bar --- --- 570 570T0070 --- --- --- * Please specify required nominal pressure/maximum static pressure when ordering. * Standard temperature range: 0 70 C Replace the designation of the part number, if necessary ** 0 0 C, designation: 000 / 0 50 C, designation: 0050 / 0 70 C, designation: 0070 i See page 26 for extra charges for and accessories. Division II 25

Process engineering Extra charges/accessories for DMU 07 DMU D DG: H, PG: 4 Type DMU 07 DMU 07 FG DMU 08 DMU 08 T DMU 09 DMU 0 D DMU D Version Price Price Price Price Price Price Price EX protection II G EEx ia IIC T4 --- --- --- --- 2 x G¼ female thread --- --- --- --- --- --- 2 x hose connection 6 mm --- --- --- --- --- On request 2 x 7 /6 UNF --- --- --- --- --- --- Other connections On request On request --- --- --- On request On request Cable connection per metre PUR cable Cable connection per metre FEP cable --- --- --- --- --- --- --- --- --- Binder connector --- --- --- --- --- --- Fixed cable connection 2 metres --- --- --- --- --- Cable extension per metre --- --- --- --- --- Output 0 20 m, -wire --- --- --- --- --- --- Output 0 0 V, -wire --- --- Other output signals On request On request On request --- On request On request On request Measuring accuracy 0.25 % FSO --- --- --- --- --- 5-point calibration report (for measuring accuracy up to 0.25 % FSO) --- --- --- --- --- SIL 2 (4 20 m only) --- --- --- --- --- --- ccessories for DMU 08/ DMU 09 DG: H PG Part no. Price Screw connector kit G2" ½" " 5225 Screw connector kit stainless steel G" 822 Junction box with pressure relief port (IP 65) 824 nchor clamp 825 i See chapter 8 for digital display units and signal processing. 26 Division II

Process engineering DMU with local display Robust stainless steel housing (safety housing) High-precision measurements with integrated transducer Mechanical, power-independent local display Chapter 2 Page 7 pplication Description For pressure measurements with a power-independent local display in combination with an electrical output signal. The DMU pressure transducers consist of a mechanical Bourdon tube measuring element and a piezo-resistive stainless steel measuring cell. The Bourdon tube measuring element is used to provide an easy-to-read analogue local display. The display is power-independent. Due to the integrated pressure transducer, high-precision measurement in parallel is possible. standardised current output is available for signal transmission and recording of measured data. The robust stainless steel housing has a solid baffle wall and blow out (safety housing). Technical specifications Nominal size 00 Measuring accuracy Pressure gauge: class.0 (EN 87-/6) Transducer: Deviation from the characteristic curve according to IEC 60770 limit point calibration (non-linearity, hysteresis, repeatability): < ± 0.5 % FSO Measuring ranges Relative pressure: 0/0.6 to 0/40 bar pplication area Static load: full scale value Dynamic load: 0.9 x full scale value Short term:. x full scale value Operating temperature range Medium: -20/+00 C mbient: -20/+60 C Storage: -40/+70 C Housing (safety housing) Housing with solid baffle wall and blow-out Window Laminated safety glass Degree of protection IP 54 (EN 60529) Process connection G½B spanner size SW 22, bottom (EN 87-/7.) Materials Housing: Stainless steel 04 Pressure connection: Stainless steel 6 L Diaphragm: Stainless steel 6 L Seal: FKM (Viton) Pressure transmission liquid Silicone oil Electrical connection Junction box dditional data transducer Output signal/supply voltage 4 20 m DC 2 6 V 2-wire Load UB 4 20 m UBmin 0.02 Current input 4 20 m < 25 m Long-term stability ±0.2 % FSO/year Temperature error band In compensated range 0 70 C % FSO/0 K Pressure transmission liquid Silicone oil i See page 240 for prices. Options Housing filling (paraffin oil) Electrical contacts Other process connections Fitting of chemical seal Division II 27

Process engineering DMU Dimensions (mm) and electrical connections Bottom connection Bottom connection, with electrical contact Removable key, delivered loose with the unit. Pin assignment table for pressure measuring cell (right junction box) Pin assignment table for electrical contact (left junction box). Example: Magnetic spring contact MK2.2 Supply - 2 Earth Earth pin Normally open contact Normally closed contact 2 Common 4 Wiring diagram 2-wire, 4 20 m 2... 6 VDC Supply - 28 Division II

Quality assurance Universal digital pressure gauges DIM 20 service instrument High flexibility due to selectable units Min./max. value memory Intuitive operation via menus Display can be rotated by 0 Zero and full scale can be calibrated pplication Description For high-precision electronic pressure measurement with local digital display, for applications such as hydraulics, pneumatics, mechanical and plant engineering. Compact microprocessor-controlled pressure gauge with thick-film ceramic measuring cell. The signal received from the pressure sensor is processed by the microprocessor, converted into the desired unit and displayed. Each device is shipped with its own measurement log. Technical specifications i See the catalogue PORTBLE MESURING INSTRUMENTS for additional test, inspection and service instruments for mobile use. See page 240 for prices. Functions Selection of units, min./max. memory, zero and full scale calibration, adjustable auto-off function, adjustable decimal point, battery status indication Displayed values Selectable pressure unit: bar/mbar/psi/inhg/mmhg/cmhg/kpa/mpa/mwc Display Multi-line LC display Line : 4.5 digit, numeric, for displaying the measured value (character height 9.5 mm) Line 2: 6-digit, alphanumeric, for displaying additional information (character height 6.8 mm) and additional symbols Display can be rotated by 0 Measuring accuracy ±0.5 % FSO as per BFSL ± % FSO (-/0 bar) Measuring ranges Relative pressure: -/0 bar, 0/2.5 bar to 0/700 bar Overpressure safety t least.5 x FS Burst pressure 60 bar at least 2.5 x FS > 60 bar at least.5 x FS Operating temperature range Medium: -20/+25 C mbient: -20/+45 C Storage: -0/+80 C Temperature error In compensated range 0/70 C 0.5 % FSO/0 K Dynamic characteristics Measuring rate 5/s Process connection G¼B (EN 87-/7.), bottom Materials Housing: P6, glass-loaded Pressure connection: Stainless steel 04 Diaphragm: Ceramic (I 2O 96 %) Seal: FKM Degree of protection IP 5 (EN 60529) Supply voltage x lithium battery.6 V (included), battery life depends on usage (max. 5 years) Dimensions (mm) Division II 29

Process engineering/quality assurance /digital pressure gauges DG: H, PG: 4 Type DMU DIM 20 Version Housing Ø 00 75 Housing Stainless steel Plastic Measuring accuracy Wetted parts 0.5 % FSO Pressure gauge: class.0 Stainless steel 6 Ti/6 L 0.5 % FSO Stainless steel 04 ceramic/fkm Connection G½B G¼B Supply voltage DC 2 6 V DC.6 V Output 4 20 m --- Measuring range Part no. Part no. Price 0/400 mbar --- --- Price -/0 bar --- 2500 0/0.6 bar 076 --- 0/ bar 077 --- Price 0/.6 bar / 0/2 bar 078 --- 0/2.5 bar 079 250 0/4 bar 080 --- 0/6 bar 08 2505 0/0 bar 082 2506 0/6 bar 08 --- 0/25 bar / 0/20 bar 084 2508 0/40 bar 085 2509 Price 0/60 bar --- --- 0/00 bar --- 25 0/60 bar --- 252 0/250 bar / 0/200 bar --- 25 0/400 bar --- 254 0/600 bar --- --- Price 0/700 bar --- 256 Extra charges (without PG) Price Spare battery PG: 4 EX protection/hrt --- communication Part no. Housing filling 6809 Price Connection ¼-8NPT Price * Wetted parts of clamp connection and dairy fitting version = stainless steel (6 L). ** Extra charge; please append N2 to the part no. when ordering. 240 Division II

Process engineering Pressure switches Differential pressure switches DS 0 Dimensions (mm) 48 Dimensions (mm) M 6 x.5 5.5 50 4 26 25 Pipe Ø 6 pplication Description Suitable for all practically neutral media such as process water, heating water, neutral gases, oils. Suitable for two-point control by means of a continuously adjustable switching point (between 0 and 00% of pressure range). robust diaphragm type movement serves as the basis for this unit. It is suitable for overpressure, vacuum and differential pressure measurements. The unit uses the same principle of operation for all three measuring applications. The pressure or the differential pressure applies a force to one side of the diaphragm. This force displaces the diaphragm system and moves the measurement range spring. switching pin mounted to the diaphragm actuates an electrical switching element. The switching point is adjusted by means of a knurled knob according to the scale. Technical specifications Pressure ranges 0/0.6 to 0/4 bar Maximum static pressure 6 bar, device is overpressure-proof up to 6 bar and vacuum-proof Operating temperature range Medium: T max = +80 C mbient: T max = +80 C Connection 2 x G / 8 female thread Pressure chamber Brass Diaphragm NBR (Perbunan) Mounting Bracket for wall-mounting Electrical connection Cable gland M 6 x.5 Switching point 0 00 % of pressure range, fully adjustable Contact Microswitch, normally closed contact (normally closed contact available without extra charge) Hysteresis pprox. 2 % Maximum rating U... C 250 V, I..., P... 500 V DG: H, PG: 4 Pressure range Part no. Price 0/0.6 bar 880 0/ bar 8804 0/.6 bar 8805 0/2.5 bar 8807 0/4 bar 8806 Extra charges options Diaphragm FKM (Viton) 8825 Fixed cable 2.5 m 8826 2 x compression fitting for 6 mm pipe, steel 8820 2 x compression fitting for 6 mm pipe, brass 8808 2 x compression fitting for 8 mm pipe, brass 884 Division II 24