SHIELD-FLEX EMI / RFI Shielded Conduit

Similar documents
SHIELD-FLEX EMI / RFI Shielded Conduit

flexible Leadership in iquatite

FLEXIBLE ELECTRICAL CONDUIT

for over 55 years Distribution and Representative Partners

for over 55 years Distribution and Representative Partners

for over 55 years Distribution and Representative Partners

/2" Ul Listed Sealtite Features Material, Color, and Finish Dimensions and Weight Descriptions

LT /8 Met L/T Non Ul 500' Features. Material, Color, and Finish Core Material. Dimensions and Weight. Descriptions

ANAMET Electrical, Inc. Worldwide Leader in Flexible Conduit Technology


Detailed Specifications & Technical Data

CABLED TWISTED PAIRS CONDUCTORS

ÖLFLEX CLASSIC 135 CH -halogen-free control cable, HFFR, flexible and screened for various applications, U 0 /U: 300/500V

Metallic Systems TYPE SPTC

CABLED SINGLE CONDUCTORS

PRODUCT INFORMATION ÖLFLEX HEAT 125 C MC. Info Improved characteristics in the event of a fire GL - Germanischer Lloyd approved

SEMI, manufacturer of superior quality electrical flexible conduit and fittings systems. Over Braided Liquid Tight Conduit ( YF-705 )

FABRIC OVER FOAM SHIELDING GASKETS

Identification Type SU+M(C)P SE(4G1,5+(2 0,75)+(2 AWG22))UL 1KV OR. Part-No

SPECIAL CABLES TEMPERATURE MEASUREMENT HARNESSING CABLES FOR RAILWAY TECHNOLOGY. den-belitsky / Fotolia

Technical data sheet LÜTZE SUPERFLEX PLUS M (C) PUR SERVO 0.6/1 kv Supply line for Bosch Rexroth and other systems For highest requirements

UNSHIELDED MULTI CONDUCTOR

Variable Frequency Drive (VFD) Cable Solutions

PANDUCT Type NNC Halogen Free Metric Wiring Duct

CABLES FOR AUTOMOTIVE MARKET Sensor and multimedia cables. Catalogue

HelaGuard. Non-Metallic Conduit & Fittings

Flame Resistance, LOI 95 >

Cable Management Solutions. HelaGuard. Non-Metallic Conduits and Fittings

Corflex. Continuous Corrugated Aluminum Sheathed PL, MC and MV Industrial Cables. Introduction Applications... 3

ÖLFLEX VFD 2XL - screened VFD cable for fixed installation or occasional flexing with UL TC-ER.

Easier! Faster! Safer!

14 HH EAC/CTP CE RoHS-II conform

PRODUCT CATALOG. Cable glands for Global Applications

LUTZE Flexible Cable and Wire Management for Industrial Automation. USA Cable Solutions

RP SMA Female Connector Crimp/Solder Attachment For RG178, RG196

Item Description Page. Halogen-free wiring cable with improved fire performance and extended temperature range 300/500 V, CE...

Cables for Railway Technology

Technical data sheet LÜTZE SUPERFLEX PLUS (C) PUR FEEDBACK Encoder cables for Siemens and other systems For highest requirements in drive technology

Engineered installation products Solutions for control panel applications

Power & Control Cable IEC

Avionics Optical Cables

Item Description Page. Halogen-free single conductor with improved fire performance and extended temperature range 300/500 V, CE...

Cable Protection Solutions for Shielding Applications CATALOG LOCK 2013 VERSION 1.0

Data sheet Connection line M12-RJ45 4-pole D-coded AWG m

Unarmored Variable Frequency Drive (VFD) Cable Termination Guide

CAN-Bus cable. CAN-Bus cable Can-Bus / Field-Bus cable for medium to maximum load requirements. chainflex cable. Overview. igus e-chainsystems

Outlets terminate all shielded and shielded cable constructions AWG ( mm) size conductors.

INDUSTRIAL SOLUTIONS MARINE CATALOGUE INNOVATIVE CABLE SOLUTIONS MEETING INTERNATIONAL STANDARDS

ÖLFLEX CLASSIC 110 H Info Benefits

Data sheet E-DAT Industry patch cord V6 IP67 - RJ m

Data sheet Connection line M12-RJ45 4-pole D-coded AWG m

CATALOG. Ty-Duct Wiring duct

Technical Data Sheet Shielded (CY) PVC Control Cable

FR-N1X1G1. Low voltage - Energy, cabling, signalling and control

Specialist Electronic Materials.

Technical Data Sheet Shielded (CY) PVC Control Cable

Traction Cable Radox 3 GKW/S EMC

FEATURES. ~ Compression resistant low loss, low density dielectric. ~ Quadraform shielding. ~ Highly reliable soldered connections

CORFLEX. Continuous Corrugated and Welded, Impervious Aluminum Sheathed PL, MC and VFD Industrial Cables. Introduction Applications...

ZHPCG CK0226 POWER CABLE WIRE & CABLE

DynaFlex series cable assemblies employ innovative designs and material technology to deliver optimized electrical and

A driving force in the market place

Data sheet. Connection cable M12 jack straight - free line end 8-pole, X-coded 0.5 m. Illustrations P/N 142M2X20005 EAN

DNV-GL HH CE RoHS-II conform

ÖLFLEX CLASSIC 110 CY

CF270.UL.D.

Technical Data Sheet Shielded (CY) PVC Control Cable

20 HUBER+SUHNER RADOX SOLAR

PHASE MASTER NOW IN 4 SIZES

Electronic Cable C O N N E C T I N G T E C H N O LO G Y W I T H P E R F O R M A N C E & P R E C I S I O N

INFORMATION. Hybrid cables. Description

Foxtronic GmbH EMI Products

SABIX Ultra. Standards: EN EN Cat C or D IEC (halogen-free)

Rail & Transit WIRE AND CABLE

Type MMV-WP Medium Voltage Wind Power Cable

DEMANDING CONDITIONS, DEMAND THE BEST!

Detailed Specifications & Technical Data

Power & Control Cables

Multi-band Bi-SectorTM Array

Data sheet chainflex CF886

IEEE 1580 TYPE T/N CABLE

Product Bulletin. Be Certain with Belden. Belden DataTwist 1200 Cables

FAKRA Jack Right Angle Connector Crimp/Solder Attachment for RG174, RG316, RG188,.100 inch, PE-B100, PE-C100, LMR-100, White Color

SOFT-SHIELD 5000 Series Conductive Jacket over Foam EMI Gaskets

FTG10OM1-0,6/1KV. 50 N/mm 2 of copper section max for fixed layings

Fast and Flexible Protection for Electrical Cables! Shureflex Nylon Liquidtight Conduit System

LIST OF PUBLISHED STANDARDS

Motion Solutions AC Induction Permanent Magnet DC Brushless DC

STANDARD PRODUCT OVERVIEW EMC FILTERS FOR MILITARY VEHICLES STANDARD EMC FILTERS FOR MILITARY VEHICLES FILTER SELECTION PROCESS. Introduction CONTENTS

Data sheet Connection line M12 plug straight - RJ45 plug straight 8-pole, X-coded 5.0 m

HexPort Multi-Band Antenna

Data sheet chainflex CF8821

Technological leadership

Ethernet Buccaneer BUCCANEER DATA. bulgin

The cables you need when you need them

DRILL CORD. Insulation Nominal Size. Approximate Amps Anixter. Number Number Thickness O.D.

Approvals (Norm references)

PROBABLY THE BEST FLEXIBLE BAR IN THE WORLD

Data sheet chainflex CF881

VERONEX Cases MATERIAL PERFORMANCE CHARACTERISTICS. MECHANICAL PROPERTIES Units Test method Result. THERMAL PROPERTIES Units Test method Result

Transcription:

Type SLA SHIELD-FLEX EMI / RFI Shielded Conduit Type EMS EMCS Type z

Wire without interference. Shielded conduit provides exceptional shielding effectiveness from electromagnetic and radio frequency interference (EMI/RFI). Use it to protect sensitive electronic circuits from outside noise in such applications as communications, radar and data transmission. But shielded conduit doesn t just keep interference out; it also keeps emissions in, which is vital to meeting European CE standards an important issue for OEMs. Fortunately, there s SHIELD-FLEX. With three easyto-install types, SHIELD-FLEX is simply a better way to wire. 42

SHIELD-FLEX Keep the Noise Out SHIELD-FLEX conduit allows for greater versatility than shielded cable in wiring configurations and retrofitting projects. With three levels of effectiveness to choose from, SHIELD-FLEX meets your needs. Best Tinned copper shielding braid over fully interlocked bronze strip inner core Better Fully interlocked bronze strip inner core Good Tinned copper shielding braid over steel strip inner core Versatile Efficient Effective SHIELD-FLEX is a liquidtight conduit that goes places other wiring can t. It can contain an unlimited combination of conductors for versatile circuit wiring. Plus, it protects wiring from crushing, impact, abrasion and the elements, and uses off-the-shelf (OTS) standard connectors intended for liquidtight flexible metal conduit. SHIELD-FLEX offers a cost-efficient solution compared to other wiring types. Its flexibility and simple assembly means it takes less time to install, shortening schedules and project budgets. And the OTS connectors are less expensive than high-end, mil spec shielded conduit or cable that require costly custom fittings. SHIELD-FLEX shields sensitive equipment and circuits from EMI / RFI emissions, both ingress and egress. Connector assemblies include a grounding ferrule that contacts the conduit s internal metallic material with the connector body, producing a direct shield-todrain (ground) simply by tightening the connector. 3

TYPE SLA Type SLA is identical to standard UL listed liquidtight flexible steel conduit, but is augmented with a tinned copper shielding braid located over the inner steel core and under its protective PVC jacket. The braid offers a minimum of 90% coverage. Please see the Shielding Effectiveness chart on page 6. APPLICATION: This conduit is intended for installation in accordance with Article 350 of the NEC (ANSI / NFPA-70). zsuitable as an equipment grounding conductor per Article 250.118(7). zsuitable for use in hazardous locations: Class I, Div. 2 and Classes II and III. zpvc jacket is resistant to a wide variety of oils, acids, alkaline and ultraviolet light. zaccepts standard metallic liquidtight fittings. Listed File #E29278. Conforms to UL360 for liquidtight flexible steel conduit. RoHS and WEEE Compliant. STANDARD COLORS: Black. Other colors and jacketing materials available upon request. WORKING TEMPERATURES: -20 C to 60 C Metal Used: Steel Plastic Used: PVC See the Chemical Resistance Guide on our website. For a low-smoke, low-flame spread, zero-halogen version, ask for HFSLA. Squarelock with Filler (Sizes 3/8" 1-1/4") Trade Size (In.) type INSIDE BEND RADIUS (IN.) Weight (Lbs.)/100 Ft. Carton Footage Reel Footage Length Part # Length Part # Length Part # SLA 3/8 SLA-10 2.0 29 100 78901 500 78903 1000 78904 1/2 SLA-11 3.0 32 100 78911 500 78913 1000 78914 3/4 SLA-12 4.2 53 100 78921 500 78924 - - 1 SLA-13 5.5 82 100 78932 400 78934 - - 1-1/4 SLA-14 7.0 102 50 78942 200 78944 - - 1-1/2 SLA-15 4.5 124 50 78952 150 78954 - - 2 SLA-16 6.0 145 50 78962 100 78964 - - Halogen-Free (HF) Series For a low-smoke, low-flame spread, zero-halogen version, ask for HFSLA, HFEMS or HFEMCS. It's ideal for field installation in confined, public areas such as subways, tunnels, etc. There are many situations and areas where PVC is not allowed for electrical construction. The jacketing material used in the Halogen-Free series virtually eliminates the release of acidic gases found in PVC products. Combustion & Flammability Properites Test Value HFSLA / HFEMS / HFEMCS Vertical Burn (Material) UL94 V-O rating; no flaming drips Vertical Burn (Conduit) UL360 Pass; no flaming drips Oxygen Index % D2863 28.5 Flame Spread Index ASTM E162 4.0; no flaming drips Flame Propagation ASTM C542 (NFPA-130) Pass; no flaming drips Smoke Generation (Flaming) ASTM E662 (NFPA-258) DS 41@1.5 min / DS 94@4.0 min Smoke Generation (Non-flaming) ASTM E662 (NFPA-258) DS 7@1.5 min / DS 45@4.0 min Toxic Gas Generation Bombardier SMP 800-C Pass Toxicity Index NES 713 3.9 Test data is based on controlled laboratory conditions and does not necessarily reflect performance in actual fire conditions. Additional product information available upon request. 4

TYPE EMS TYPE EMCS Type EMS has an inner core made from a fully interlocked bronze strip and does not contain a braided shield. Please see the Shielding Effectiveness chart on page 6. Accepts standard metallic liquidtight fittings. RoHS and WEEE Compliant. STANDARD COLORS: Gray. Other colors and jacketing materials are available upon request. For UL and CSA version, consult factory. WORKING TEMPERATURES: -55 C to 105 C Metal Used: Bronze Plastic Used: PVC See the Chemical Resistance Guide on our website. For a low-smoke, low-flame spread, zero-halogen version, ask for HFEMS. Type EMCS is a hybrid of SLA and EMS. It utilizes the same bronze core and PVC jacket as EMS, but gets further screening protection from a tinned copper braid, as found in the SLA product. Please see the Shielding Effectiveness chart on page 6. Accepts standard metallic liquidtight fittings. RoHS and WEEE Compliant. STANDARD COLORS: Black. Other colors and jacketing materials available. For UL and CSA version, consult factory. WORKING TEMPERATURES: -55 C to 105 C Metal Used: Bronze Plastic Used: PVC See the Chemical Resistance Guide on our website. For a low-smoke, low-flame spread, zero-halogen version, ask for HFEMCS. Interlock Interlock Trade Size (In.) type INSIDE BEND RADIUS (IN.) Weight (Lbs.)/100 Ft. Carton Footage Reel Footage Length Part # Length Part # EMS 3/8 EMS-10 3.0 27 100 78801 1000 78804 1/2 EMS-11 3.0 35 100 78811 1000 78814 3/4 EMS-12 4.0 43 100 78822 500 78824 1 EMS-13 4.0 85 100 78832 400 78834 1-1/4 EMS-14 4.5 101 50 78842 200 78844 1-1/2 EMS-15 7.0 140 50 78852 150 78854 2 EMS-16 9.5 180 50 78862 100 78864 2-1/2 EMS-17 12 232 25 78872 - - 3 EMS-18 13.5 320 25 78882 - - 4 EMS-19 17.0 388 25 78892 - - EMCS 3/8 EMCS-10 3.0 27 100 78701 500 78703 1/2 EMCS-11 3.0 35 100 78711 500 78713 3/4 EMCS-12 4.0 43 100 78722 500 78724 1 EMCS-13 4.0 85 100 78732 400 78734 1-1/4 EMCS-14 4.5 101 50 78742 200 78744 1-1/2 EMCS-15 7.0 140 50 78752 150 78754 2 EMCS-16 9.5 180 50 78762 100 78764 5

Shielding Effectiveness The graph below depicts a general comparative shielding effectiveness (attenuation in dbs) of all three types of SHIELD-FLEX conduit. The dotted line indicates a comparison to standard unshielded liquidtight flexible conduit Type LA. The spectrum of test frequency is from 1 to 10 Electric Field, to 100 to 1 GHz Planewave Field and 2 GHz to 6 GHz Microwave Field. Tests were performed per MIL-STD-285 on 1" trade-sized conduit using standard liquidtight fittings from Thomas & Betts Series 5300. Results are based on controlled laboratory conditions and may vary in actual field-installed conditions. 140 120 ATTENUATION (db) 100 80 60 EMCS EMS SLA LA 40 20 1 10 100 450 700 850 1 GHz 2 GHz 3 GHz 6 GHz TEST FREQUENCY 46

Our Expertise Works for You For more than 55 years, Electri-Flex has been your single source for flexible conduit, and we bring that experience to each project. By providing reliable, insightful advice on every wiring issue you face from fatigue concerns, grounding and environmental issues to product strength and chemical resistance we help you meet your challenges. We can help create the perfect solution for your application, as well. Our skilled engineers use advanced software to design and prototype custom wiring products that meet your specific needs. And everything is manufactured in a vertically integrated system that provides complete quality control through the entire production process. Markets We Serve z Medical z Military z Industrial z Government / Defense z Commercial z Telecommunications z Aerospace z Public transit z Utilities Applications z Air Handling Equipment (HVAC) z Test & Measurement Equipment z Data Centers z Variable Speed Drives z Commercial-off-the-shelf (COTS) z CE European Standard z Radio Broadband / Antenna z Solar / Wind Energy z Ship Building z Medical Diagnostics Equipment z Wireless Communication 7

Family owned and operated since its inception and incorporation in 1955, Electri-Flex remains focused on the quality, service and partnership values that have resulted in its leadership position in the electrical industry. The company s innovations have included its premier Liquatite line and other manufacturing patents, as well as numerous packaging improvements. If you are seeking cost-effective, high-quality flexible conduit for any application, give us a call. Whatever your design challenge, we can provide a solution. SHIELD-FLEX 222 West Central Avenue Roselle, IL 60172-1994 Toll Free: (800) 323-6174 (630) 529-2920 Fax (630) 529-0482 Sales Department E-mail: sales@electriflex.com Marketing Department E-mail: mktg@electriflex.com Technical Assistance E-mail: eng@electriflex.com www.electriflex.com Electri-Flex Company 2011 SHLD 2nd - 03 / 11 Made in the USA