TECHNICAL SPECIFICATIONS

Similar documents
Technical specification agenitor 404b NG

Technical specification agenitor 408 NG

DIESEL GENERATOR SET MTU 18V2000 DS1400

QUOTATION BLADE 7 LX. Product code GEAL6S2BAA

Technical specification agenitor 306 NG

DIESEL GENERATOR SET MTU 12V4000 DS1650

DIESEL GENERATOR SET MTU 16V2000 DS1000

DIESEL GENERATOR SET MTU 4R0113 DS80

DIESEL GENERATOR SET MTU 20V4000 DS3250

DIESEL GENERATOR SET MTU 16V2000 DS1100

Company name: Created by: Phone:

Industrial Diesel Generator Set KD1650-E 50 Hz - Emission Optimized EPA Tier 2 Compliant

DIESEL GENERATOR SET DS03200D5S

Company name: Created by: Phone:

GMK EV SERIES. Single Stage Oil Sealed Rotary Vane Pump

DIESEL GENERATOR SET MTU 16V2000 DS KVA

Industrial Diesel Generator Set KD1100-F 50 Hz Fuel Consumption Optimized

DIESEL GENERATOR SET DP01800D5S

DIESEL GENERATOR SET DS01650D5S

Motors and Gearboxes for Biomass Heating Systems. Energy efficient Durable Quiet as a whisper Compact

DIESEL GENERATOR SET MTU 12V4000 DS2000

DIESEL GENERATOR SET MTU 20V4000 DS3100

DIESEL GENERATOR SET MTU 16V4000 DS2250

SIVASA Doosan Series. SD250 Technical Data

Company name: GSI Created by: Xiao Ying Wong Phone: Date: 10/03/2017 Client: Client Number: Contact:

DIESEL GENERATOR SET DP03000D5S

DIESEL GENERATOR SET MTU 20V4000 DS2650

DIESEL GENERATOR SET MTU 16V4000 DS2250

DIESEL GENERATOR SET MTU 16V4000 DS2500

DIESEL GENERATOR SET MTU 16V4000 DS2500

Technical description CHP MODULE

Test Stand For Air Turbine Starters >TATS4<

Industrial Diesel Generator Set KD2500-F 50 Hz Fuel Consumption Optimized

DIESEL GENERATOR SET DG00660D5

DIESEL GENERATOR SET MTU 12V1600 DS660

DEUTZ Engine Documentation Genset Manual. BF4M2012C (D2OC74,9) - 50 Hz 1/5 DEUTZ AG

LCU DX Efficient cooling with no loss of space

Subsidiaries: PORTUGAL POLAND GERMANY UK SINGAPORE UAE PANAMA DOMINICAN REPUBLIC ARGENTINA ANGOLA SOUTH AFRICA

DIESEL GENERATOR SET MTU 20V4000 DS3300

SSW07. Soft Starters. Applications. Standard Features

abc CPD7948/075 Rotors, rotor shafts and rotor casings are coated with an anti-corrosive and anti wear coating to prolong element life and efficiency.

DIESEL GENERATOR SET MTU 12V4000 DS1650

SD Series Non-Fused Load Switches

JCB DIESEL GENERATOR TECHNICAL SPECIFICATIONS

Lithium Power Cabinets

avian sales & service Screws l Barrels l Granulators Shredders l Pulverisers Tel: l Fax: l

NCF fans 50 Hz. Protection class IP 55

DIESEL GENERATOR SET MTU 12V4000 DS1750

VARIO. VARIO Separation of fine dust particles. The VARIO series is particularly suitable for separation of fine dust.

DIESEL GENERATOR SET MTU 20V4000 DS3600

DIESEL GENERATOR SET MTU 10V1600 DS500

SILOXA FAKA Gas Cleaning System

Data sheet: Wilo-VeroTwin-DPL 65/ /2

DIESEL GENERATOR SET MTU 16V4000 DS2250

CBU144. Compact Booster Unit - single pump To ensure the quality of potable water according to EN1717. Product specification sheet

Part III : Technical Specification POS B)

Mixed Flow Roof Fans (RMH)

Oil/Air Cooler Units. Standard series EL Type. Test procedure certified following EN 1048

Sewage transport Submersible pumps

Fan coil unit NBS 100/150

Technical specification

CHP

DIESEL GENERATOR SET MTU 16V4000 DS2500

GENCORE 5 FUEL CELL SYSTEM System Fundamentals

Data sheet: Wilo-VeroTwin-DPL 40/ /4

DIESEL GENERATOR SET MTU 12V4000 DS2250

GÝROL FLUID DRIVES GÝROL FLUID DRIVES SAVE ENERGY HOW GÝROL FLUID DRIVES WORK

DIESEL GENERATOR SET MTU 20V4000 DS4000

Boiler Operation, Maintenance, and Settings. Matthew Baxter Technical Director, Core Biomass

TRT SYSTEM. Product Description

PROJECT MANUAL GUIDE SPECIFICATIONS FOR: PFANNENBERG SERIES EB COMPACT PACKAGED CHILLERS PART 1 GENERAL

Introducing the TM /

This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

Natural gas engine E 0836 LE 202 Technical data

Company name: BKB Building Solutions Created by: Michael Chlopek Phone: Date: 14/03/2017

Data sheet: Wilo-CronoLine-IL 125/210-5,5/4

Company name: GRUNDFOS (Singapore) Pte. Ltd. Created by: Angie Ang Phone: Date: 23/03/2017

Industrial Diesel Generator Set KD1100-F 50 Hz Fuel Consumption Optimized

Data sheet: Wilo-CronoTwin-DL 65/250-4/4

Series VENTS OVK. Low pressure axial fans in the steel casing with the air capacity up to m 3 /h for wall mounting

CR10-07 A-FJ-A-E-HQQE 3x400D 50 HZ

Liquid ring vacuum pumps with magnetic coupling

COMMERCIAL BOILERS Eco-HK / Eco-PK KW

Sample Specifications 2110_KA.DOC KOBELCO KNW SERIES 1 OF 10 AIR-COOLED, OIL FREE AIR COMPRESSOR Frame 0, 1, HP

Data sheet: Wilo-Economy MHI 202 (3~400 V, EPDM)

Data sheet: Wilo-VeroLine-IPH-W 65/ /4

IN-LINE DUCT FANS MIXVENT-TD Fan Systems

HP14/20/28 P50 P75 P100/120 P150/170/200 P500

Data sheet: Wilo-VeroLine-IPL 100/ /4

Biogas Engine E 0836 LE 202 Technical Data for 60%-CH 4, 40%-CO 2

Data sheet: Wilo-CronoLine-IL 65/160-5,5/2

This catalog contains the following geothermal accessory products and specification guides:

Data sheet: Wilo-CronoLine-IL 65/130-4/2

Data sheet: Wilo-CronoLine-IL 50/120-2,2/2

Data sheet: Wilo-CronoLine-IL 80/145-1,1/4

Data sheet: Wilo-CronoLine-IL 50/200-1,5/4

Low voltage AC drives. ABB micro drives ACS to 3 hp/0.18 to 2.2 kw Catalog

Fristam Powder Mixer. Function Principle

CRN15-09 A-P-G-V-HQQV 3x400/ HZ

Transcription:

TECHNICAL SPECIFICATIONS E3 V 2.0 25 KW MOBILE POWER UNIT the future of decentralized energy ENTRADE ENERGIESYSTEME AG

E3 v 2.0 25 kw Mobile Power Unit Operating mode: Type: Downdraft fixed-bed gasifier 1 x E3 System Equipment performance Total installed capacity: 26 kwel Declared net capacity: 25 kwel Nominal heat output: 60 kwth Heat output from CHP part: 43 kwth Heat output from reformer: 17 kwth Total efficiency: 85% Electrical efficiency: 25% Thermal efficiency: 60% Temperature of heat output: 90 C / 60 C Electrical Output: 400 V / 50 Hz Operating hours: 8000 h/a Emissions Sound: Ash remaining approx: 60 db(a) 0.2 0.4 kg/h Feedstock and utilities Feedstock: Din EN Plus 6mm A1 or certified E-Fuel biomass waste pellets Feedstock Consumption: 23 kg/h Power: Electrical power (3 Phase, 64 Amps) Cooling water: Antifreeze MITAN Alpine c11 (50 Vol-% recommended) Motor oil: Fuchs Titan Ganymet Ultra Paper filter: Large: Mann Luftfilter C 30 850/2 Police : Mann Luftfilter C 17 225/3.4 Producer gas Gas Composition (Wood Gas): CO 23% / CO2 9% / H2 19% / CH4 1.8% Average calorific value: >5200 kj/m 3 Temperature of syngas at reformer exit: 700 C to 800 C Temperature of syngas after cooling: 80 C to 100 C Temperature of syngas/air mixture: 40 C to 60 C 2

Miscellaneous Control Unit: Time of commissioning: Authorization requirement: Fully automated operation 2-72 hrs Depends on region Engine Type: General Motors 4.3L Construction type: V 6 Process: Gasoline engine Cubic capacity: 4.3 liter Rated rpm: 1500 rpm Cooling: Recirculating water Sound pressure level: 60 db(a) Exhaust gas temperature: 120 C Oilfilling: 4.3 liter Generator Type: Asynchronous generator Type of operation: Mains parallel operation Nominal power: Electr. (max.): 25 kw, 31.25 KVA Cos Phi: 0,85 (100%) Nominal voltage: 400 V Frequency: 50 Hz Pole number: 4 Operating mode: S1 Protection class: IP55 Monitoring: PTC Connection Electr. input: 400 V, 50 Hz (three-phase rotary current) Electr. output: 400 V, 50 Hz (three-phase rotary current) Electr. fuse protection: Generator 63 A Switchboard 80 Ah Cable dimensioning: Generator: 16 mm 2 Thermal return line: Thermal supply line: Exhaust Gas line: Control system: Switchboard: 25 mm 2 (<30 m cable length) 35 mm 2 (<200 m cable length) 1 inlet with inner thread 1 inlet with inner thread 2 flange Schneider Service and Operation Ash Removal: Oil Exchange: Every 60 to 80 hrs (with manual ash removal system) Every 200 to 250 hrs 3

E3 SYSTEM without enclosure Dimensions per E3-unit: 1.86 m x 1.56 m x 2.00 m E3 SYSTEM with enclosure (Plug & Play Solution) Enclosure Type: 20 ft HC Container Required space: 15 m 2 Dimensions: 6.058 m x 2.438 m x 2.896 m Weight: approx. 6 tons OPTIONAL Internal feedstock storage: 2.10 m x 2.10 m x 2.00 m Filling volume of feedstock storage: max. 4.0-5.2 m 3 Storage capacity of feedstock: max. 2.6-3.4 ton at 0.65 ton/m 3 (lasting approx. 5 6.5 days) Required conditions at installation site In order to guarantee a smooth commission of the system onsite, the customer provides the following site installations: Foundation with sufficient access to all system components Sufficient housing/ roofing only (required for E3 System witout enclosure) Sufficient air supply with appropriate circulation rate (required for E3 System witout enclosure) Three phase connection with 400 V, 64 A, 50 Hz Broadband connection for data delivery DHCP setup with static IP-address for the system (such as 192.168.1.200) - Please provide the following information: - Router (brand, type, model etc.) - ADSL external or router integrated - Internet/Lan Infrastructure on site - IP address range or Gateway of the Router Water connection - 90 C flow and 60 C return-flow - Pipe DIN25 or bigger - Flow rate > 2000 l/h 4

Scope of delivery The E3 25 kw is delivered as a fully functioning system including all components required for operations. 20ft High Cube Container The following components comprise one E3 25 kw system: High temperature reformer Gasoline engine Asynchronous generator Divisible pallet system Fuel lock system Hot air blower system Auger system fully automated vacuum pellet feed Safety system for over pressure with bursting disc Electric ball valves for automatic prevention of gas Pumping system Gas heat exchanger Grate motor Security flaring system High performance cyclone filtration system for ash removal Dry filter system Exhaust gas heat exchanger Sound absorbers Air and gas tight ash container Switch cabinet Soft starter Pressure and temperature sensors Fill-level sensor Touch panel for the control unit CO-warning central system Grid protection relais Remote monitoring Central Processing Unit with software for fully automated operations Uninterupted Power Supply unit for emergency power supply for safe shut down 5

E3 v 2.0 25 kw Mobile Power Unit Assembly dimensions E3 System without enclosure 6

E3 v 2.0 25 kw Mobile Power Unit Connections on Container E3 System with enclosure 7