B58 Series Regulator Residential Regulator

Similar documents
B57 Series Regulator Residential Regulator

B57 Series Regulator Residential Regulator

B42 Series Regulator Residential Regulator

B531 Series Regulator Twin Parallel Commercial Regulators

B531 Series Regulator Twin Parallel Commercial Regulators

B42 Series Regulator. Advanced Metering and Regulation Technolgy at Work

627 Series Pressure Reducing Regulators

Type HSR Pressure Reducing Regulator for Residential, Commercial or Industrial Applications

627 Series Pressure Reducing Regulators

SPRING COLOR. Blue-black Black. Green-black Black Red-black Blue-black Green-black Green Orange. Red Red-black

SR100 Series Service Regulators. Technical Bulletin

627 Series Pressure Reducing Regulators

SSV SL-022 Safety Shut-off Valve

cs200 series commercial / Industrial pressure reducing regulators

Type HSR Pressure Reducing Regulator for Residential, Commercial, or Industrial Applications

243 Service Regulators. Outlet Pressure Ranges and Springs. Basic Models. Pipe Size. Temperature Limits. Buried Service

289 Series Relief Valves

P200 Pressure Regulator

P99 Pressure Reducing Regulator

Y610A, Y611A, and Y612A Series Vacuum Service Equipment and Relief Valves

P200 Pressure Regulator

type 630r relief Valve

P200 Pressure Regulator

Type 289P Pilot-Operated Relief Valve

Types 1808 and 1808A Pilot-Operated Relief Valves or Backpressure Regulators

Types 1808 and 1808A Pilot-Operated Relief Valves or Backpressure Regulators

Y690A Series Pressure Reducing Regulators

Type 289P Pilot-Operated Relief Valve

Installation and Operating Instructions For MANUAL MANIFOLD SDLA& SDLAHP SERIES

CP400 Series Commercial/Industrial Pressure Loaded Pressure Reducing Regulators

Built-in Slam-Shut Valve. Independent pneumatic control Accuracy class: ±5% Response time: 1 second. 1/2, 11/16, and 3/4-inch (13, 18, and 19 mm)

67 Series Pressure Regulators

B-34 Series Regulator Parts List. Effective June 2002

CS800 Series Commercial/Industrial Pressure Reducing Regulators

SERIES 2100 Resilient Seated Butterfly Valves

SERIES 2200 Replaceable Seat Butterfly Valves

ALITA LINEAR AIR PUMP OPERATION & MAINTENANCE MANUAL. AL- Model Number Date Code / Serial Number Date of Purchase

T205VB Series Tank Blanketing Vacuum Breakers

Cast Iron Liquid Relief Valves

S203 Series Relief Monitor Regulators

T200 Pressure Regulator

T205 Series Tank Blanketing Regulators

T205 Series Tank Blanketing Regulators

Hand Expansion Valves Built Stronger to Last Longer Sizes: 6mm (¼ ) to 305mm (4 )

Solutions beyond products...

Installation, Operation and Maintenance of Airflex Quick Release Valve

Type 310A-32A Pressure Reducing Regulator

Installation Manual DIAPHRAGM WELL TANK

Installation, Operation & Maintenance Manual

type 122a three-way Switching Valve

P630 High Flow Gas Regulator

SERIES 9000 Double Offset HP Butterfly Valves

300 Series INSTRUCTION MANUAL. Compressed Air Filters Models 302 (grade) through 317 (grade)

THE WARRANTY SET FORTH HEREIN IS GIVEN EXPRESSLY AND IS THE ONLY WARRANTY GIVEN BY THE COMPANY WITH RESPECT TO THE PRODUCT.

INTRODUCTION INSTALLATION

P SERIES PUMPS. 18mm Versions Nickle-Aluminum Bronze Models: P , P , P , P , P , P , P

P600 Pressure Regulator

MODEL 200 MULTI-JET FLOW METER

BEFORE YOU BEGIN LIST OF COMPONENTS. Isopropyl SWITCH SCOTCH-BRITE PAD ALCOHOL PREP PAD SWITCH HARNESS REVOLVER PCM COVER STICKER

Y690A Series Pressure Reducing Regulators

RP-1350 Rev. 1. Parts List. Model 441-S Regulator. Parts List. Copyright 1999 Invensys Energy Metering

Watts Series CSM-61. Flow Measurement/Balancing Valves Sizes: 1 1 4", 1 1 2", 2", 2 1 2", and 3" (32, 40, 50, 65 and 80mm) Installation Instructions

CRD610 Automatic Fitting Inserter

GRINNELL Model B302 and Model BN302 Grooved End Butterfly Valves with Gear Operators or Lever-Lock Operators General Description

Cash Valve. Type G-60. High Capacity Pressure Regulator. Flow Control. Issued - February 2001 CAVMC-0511-US-0609 ISO 9001 Certified

AMERICAN AVK COMPANY AVK SERIES 24 - HIGH PRESSURE, WET BARREL HYDRANT FIELD MAINTENANCE AND INSTRUCTION MANUAL TABLE OF CONTENTS

Refinery Supply Company, Inc.

NECO Pumping Systems

Gas Pressure Regulator HON 226

P627 High Flow Gas Regulator

TBM Series 3-Way Ball Valve

APCO ASR-400/450 SEWAGE AIR RELEASE VALVES

P627 High Flow Gas Regulator

Installation, Operation and Maintenance Manual for Pressure/Vacuum Relief Valves (Spring Loaded)

4000SS. For other repair kits and service parts, send for Ames Repair Parts Price List, PL-A-RP-BPD.

PRG 350 Series Stainless Steel Regulators

INSTRUCTION MANUAL. CVS P32 LP Gas Reducing Regulator

Easytork Solenoid Valve IOM

MODEL 200 MULTI-JET FLOW METER

Manufacturing Facility is ISO9001:2000. Welded Steel Pipe Conform to ASTM A53. Threads Conform to ASME B1.20.1

PORTER FLOWMETERS & FLOW CONTROLLERS. Technology you can trust

Dome-Loaded Pressure Reducing BD-Series

Operating and Installation Instructions

IMPORTANT OPERATING CONDITIONS. Failure to comply with any of these conditions invalidates the warranty. STANDARD CONFIGURATIONS

Introduction Maximum Inlet Pressures. Installation and Start-Up. Servicing and Adjustment CAUTION CAUTION CAUTION. General Notes

Crosby Style JQ Pressure Relief Device. Flow Control

BC Brake Caliper. (i) MEX (55) QRO (442) MTY (81) DIST. AUTORIZADO

STAINLESS STEEL FORGED FITTINGS 3000lb 304/304L & 316/316L Forged Stainless Steel Fittings Product Specifications

Series 867 Reduced Pressure Zone Assemblies

Installation Guide. Marine Filter SURT023M SURT024M

DAP-625S and DAP-875S

R627 High Flow Gas Regulator with Internal Relief

AVK SERIES 41 SWING CHECK VALVE FIELD MAINTENANCE AND INSTRUCTION MANUAL FOR SWING CHECK VALVES 3" - 12"

Vacuum Relief Valves Operation and Maintenance

P627 High Flow Gas Regulator

CRD600 Automatic Fitting Inserter

Operators Manual. Model 3370 Air Cooled Recirculator rev.8/98

Model BP6150. Triplex Ceramic Plunger Pump Operating Instructions/ Manual

MetroPrime 22MPC Self-Priming Centrifugal Pump

D I V I S I O N O F M A R S H B E L L O F R A M

Transcription:

B58 Series Regulator Residential Regulator The B58 regulator is ideally suited for use where inches of water column or pounds delivery pressure are desired for uses including utility services, small boilers, and other similar applications. The B58 is ideal for situations where rapid response is required, such as on/off loads, and can be utilized to avoid shock problems. Description B58R The B58R is a spring-loaded, self operated regulator with an internal relief (designated by the letter R ) valve. The 1" or optional ¾" internal relief valve provides excellent relief capacity. B58N The B58N is the same as the B58R (above) with the exception that it does not have an internal relief (designated by the letter N ) valve. This model may be used in situations where an over-pressure internal relief valve is not required. Option Designations R Internal Relief N No Internal Relief HP All models for outlet pressures above 0.5 PSIG Benefits Light weight Easy to install Smooth control over widely varying inlet pressures No special tools required for outlet pressure adjustment Features Field interchangeable orifice Field interchangeable adjustment spring 27 sq. in. diaphragm area Spring-loaded internal relief valve assembly Wide range of NPT valve body sizes Primary and secondary informational badges (4 lines available with 24 characters per line) Serial numbers available upon request SPECIFICATIONS

SHIPPING WEIGHT Eight regulators per box Box weight: 52 lbs. B58 DIMENSIONS (INCHES) Valve Body A B C D E F G R 3/4" & 1" 3-13/16 1-21/32 6 7-5/16 3-5/16 5-3/16 10-5/32 1-1/2 1-4 1-7/8 6 7-5/16 3-5/16 5-3/16 10-5/32 1-1/2 2

OPERATIONAL SCHEMATIC 3

SPRING DATA - SPRING COLOR OUTLET PRESSURE RANGE* Model - B58 Inches w.c. Brown 4.5 to 5.5 Dark Green 5.0 to 6.5 Grey 4.0 to 9.0 Light Green 5.5 to 8.0 Black 7.3 to 11.0 Blue 8.0 to 12.0 Silver 11.0 to 16.0 Model - B58HP** PSIG Red/grey 0.75 to 1.1 Yellow 0.9 to 1.4 Red 1.3 to 2.0 White 1.75 to 2.5 Relief Spring Data Black 7" w.c. above set point *Spring ranges are approximate and may vary by application. **Warning: Springs are not interchangeable between B57 and B57HP. ORIFICE DATA - WIDE OPEN FLOW COEFFICIENTS AND MAXIMUM PRESSURE DATA Orifice Size K - Factors Maximum Operating Inlet Pressure R Models Max Emergency Inlet Pressure In. w.c. Delivery PSIG Delivery All Outlet Max Emergency Outlet Pressure (Containment) Pressure PSIG Pressure PSIG Inlet Pressure PSIG In. w.c. Delivery PSIG Delivery 1/8" 35 125 175 300 0.144"x 50 125 175 300 75 125 175 300 x 75 125 125 300 145 125 125 300 x5/16" 145 100 100 150 5/16" 235 100 100 150 3/8" 325 65 60 150 1/2" 500 40 40 100 1/2"x9/16" 500 40 40 100 Note: N model regulators cannot be used without additional safety equipment above 60 PSIG inlet pressures. OPERATING TEMPERATURE RANGE -20 F to 150 F. Silicone valve seats available below -20 F. 18 PSIG 60 PSIG 4

CONSTRUCTION takes pride in delivering American made products with the utmost concern for safety, quality, and customer satisfaction. Material Construction Valve Body: High tensile strength cast iron (ASTM A-126, Class A) Orifice: Aluminum Valve Seat: Buna-N Valve Stem: Nylon Lever Pin: Stainless steel (Type 303) Lever: Zinc and dichromate plated steel (AISI C1010) Upper Diaphragm Plate: Zinc and dichromate plated steel (14 gauge steel) Lower Diaphragm Plate: Die cast aluminum (ASTM B-85 Alloy SC84A) Diaphragm: Buna-N and reinforcing fiber Vent Valve/Seat: Neoprene Vent Screen: Stainless Steel (16 mesh) Adjustment Ferrule: Acetal; die cast aluminum for HP model (ASTM CS43A) Seal Cap: ABS Plastic Diaphragm Case: Die cast aluminum (ASTM B85 - Alloy SC84A) Valve Stem Insert: Acetal VALVE BODY SIZES Inlet Outlet Straight 1/2" 1/2" x 3/4" 3/4" x 3/4" 1" x 3/4" 1- x 1" 1" x 1" 1- x 1-1- x X indicates the valve body is available in that configuration. 5

CORRECTION FACTORS FOR NON-NATURAL GAS APPLICATIONS The B58 may be used to control gases other than natural gas. To determine the capacity for gases other than natural gas, multiply the values within the capacity tables by a correction factor. The table below lists the correction factors for some of the more common gases: Gas Type Specific Gravity Correction Factor (CF) Air 1.00 0.77 Butane 2.01 0.55 Carbon Dioxide (Dry) 1.52 0.63 Carbon Monoxide (Dry) 0.97 0.79 Natural Gas 0.60 1.00 Nitrogen 0.97 0.79 Propane 1.53 0.63 Propane-Air-Mix 1.20 0.71 To calculate the correction factor for gases not listed in the table above, use the gases specific gravity and insert it in the formula listed below: Correction Factor (CF) = Where: SG 1 = Specific gravity of the gas in which the capacity is published. SG 2 = Specific gravity of the gas to be controlled. Wide Open Flow Calculations For wide-open orifice flow calculations use the following equations: For P 1/P 2 < 1.89 use: Q K P2( P1 P2) For P 1/P 2 > 1.89 use: KP1 Q 2 Where: P 1 = Absolute Inlet Pressure (PSIA) Q = Flow Rate (SCFH) P 2 = Absolute Outlet Pressure (PSIA) K = Orifice Coefficient (SCFH/PSI) 6

B58 SERIES RESIDENTIAL REGULATOR MODELS N AND R 7" w.c. Capacity Table (1" Droop*) 3/4" x 3/4" Valve Body Capacities in SCFH of 0.6 S.G. gas; base conditions of 14.7 PSIA and 60 F. Typical Capacity Info. Orifice Size Inlet Pressure PSIG 1/8" 0.144" x x x 5/16" 5/16" 3/8" 1/2" Type and model B58R 8" w.c. 65 70 90 100 105 135 210 Regulator 10" w.c. 75 80 100 110 120 215 230 Inlet size 3/4" 12" w.c. 65 70 90 100 120 125 135 250 285 Outlet size 3/4 14" w.c. 75 80 100 110 130 140 200 275 300 Spring color Lt. Green 16" w.c. 80 90 115 120 200 215 225 295 310 Position 5 21" w.c. 90 100 135 150 230 250 260 315 380 24" w.c. 70 100 115 170 170 250 275 285 350 400 1 80 120 130 220 230 275 280 300 400 425 2 110 210 235 185 250 325 375 400 525 535 3 195 250 300 350 350 400 420 500 550 600 5 250 300 400 440 450 500 550 590 625 650 10 350 500 510 610 630 650 700 700 700 20 500 600 720 750 760 765 765 800 30 550 800 810 820 820 825 830 830 40 700 875 900 900 50 800 920 950 910 60 850 975 1000 1010 70 900 1000 1060 1060 80 925 1025 1050 1065 90 975 1030 1090 1100 100 1000 1010 1025 1110 120 1035 1045 1100 1115 125 1090 1100 1120 1120 1/2" x 9/16" Inlet Effect (inches w.c.) B 0.1 0.1 0.2 0.2 0.3 0.3 0.4 0.4 0.7 0.9 Lock Up (inches w.c.) C 0.2 0.3 0.3 0.4 0.4 0.6 0.6 0.7 0.7 0.9 Notes: B. Change in outlet pressure for 10 PSIG inlet pressure change. C. Outlet pressure increase required for lock up. *Individual regulator performance may vary from data shown. Inlet pressure is too low to achieve desired outlet pressure. Do not operate orifice in shaded inlet pressure area. Capacity in black outline generated with black spring. 7

B58 SERIES RESIDENTIAL REGULATOR MODELS N AND R 7" w.c. Capacity Table (1" Droop*) 3/4" x 1" and 1" x 1" Valve Bodies Typical Capacity Info. Inlet Pressure PSIG 1/8" 0.144" x Capacities in SCFH of 0.6 S.G. gas; base conditions of 14.7 PSIA and 60 F. x Orifice Size x 5/16" 5/16" 3/8" 1/2" Type and model B58R 8" w.c. 60 65 70 75 80 100 180 Regulator 10" w.c. 75 80 85 90 95 155 240 Inlet size 3/4" 12" w.c. 55 80 85 90 95 100 110 260 320 Outlet size 1" 14" w.c. 60 90 95 100 110 115 140 300 350 Spring color Lt. 16" w.c. 65 100 110 120 130 140 270 320 370 Position: Green 5 21" w.c. 75 115 130 140 250 280 310 390 400 24" w.c. 70 80 125 140 190 290 320 350 400 475 1 80 95 240 175 260 320 330 360 490 535 2 90 250 300 345 350 415 470 540 775 800 1/2" x 9/16" 3 200 300 335 440 460 525 620 750 880 1020 5 270 405 450 580 640 725 915 1035 1040 1110 10 370 575 680 840 940 970 1470 1500 1520 1590 20 600 790 1210 1300 1740 1750 2135 2200 2225 2240 30 775 1020 1675 1700 2100 2110 2500 2500 2500 2500 40 940 1230 2000 2020 2280 2300 2500 2500 2500 2500 50 1100 1360 2310 2390 2500 2500 2500 2500 60 1235 1425 2500 2500 2500 2500 2500 2500 70 1430 1600 2500 2500 2500 2500 2500 80 1580 1710 2500 2500 2500 2500 2500 90 1730 1775 2500 2500 2500 2500 2500 100 1890 1900 2500 2500 2500 2500 2500 120 2140 2085 2500 2500 2500 125 2160 2175 2500 2500 2500 Inlet Effect (inches w.c.) B 0.1 0.2 0.2 0.3 0.2 0.4 0.4 0.4 0.5 0.7 Lock Up (inches w.c.) C 0.3 0.2 0.3 0.3 0.3 0.4 0.4 0.4 0.6 1.1 Notes: B. Change in outlet pressure for 10 PSIG inlet pressure change. C. Outlet pressure increase required for lock up. *Individual regulator performance may vary from data shown. Inlet pressure is too low to achieve desired outlet pressure. Do not operate orifice in shaded inlet pressure area. Capacity in grey outline generated with Black Spring Capacity in black outline generated with Brown Spring. 8

B58 SERIES RESIDENTIAL REGULATOR MODELS N AND R 7" w.c. Capacity Table (1" Droop*) 3/4" x 1-, 1" x 1-, and 1- x 1- Valve Bodies Typical Capacity Info. Inlet Pressure PSIG 1/8" 0.144" x Capacities in SCFH of 0.6 S.G. gas; base conditions of 14.7 PSIA and 60 F. x Orifice Size x 5/16" 5/16" 3/8" 1/2" Type and model B58R 8" w.c. 55 60 65 70 95 200 210 Regulator 10" w.c. 60 65 85 90 100 210 220 Inlet size 1-12" w.c. 55 70 80 90 110 115 235 300 410 Outlet size 1-14" w.c. 60 80 85 90 225 235 320 360 450 Spring color Lt. Green 16" w.c. 65 80 90 95 250 270 385 415 510 Position: 5 21" w.c. 80 90 210 250 325 350 420 530 640 24" w.c. 55 90 100 220 280 350 410 500 645 695 1 65 90 190 275 300 445 450 810 750 885 1/2" x 9/16" 2 90 265 340 425 475 620 690 1060 1100 1280 3 200 345 415 525 625 815 940 1520 1475 1585 5 280 455 550 690 880 1125 1300 1785 2015 2020 10 400 570 860 900 1450 1585 2150 2500 2500 2500 20 575 810 1250 1275 2155 2200 2500 2500 2500 2500 30 745 1035 1610 1630 2500 2500 2500 2500 2500 2500 40 910 1270 1980 2000 2500 2500 2500 2500 2500 2500 50 1075 1500 2275 2290 2500 2500 2500 2500 60 1250 1710 2500 2500 2500 2500 2500 2500 70 1430 1945 2500 2500 2500 2500 2500 80 1585 2185 2500 2500 2500 2500 2500 90 1720 2380 2500 2500 2500 2500 2500 100 1895 2500 2500 2500 2500 2500 2500 120 2265 2500 2500 2500 2500 125 2350 2500 2500 2500 2500 Inlet Effect (inches w.c.) B 0.1 0.2 0.2 0.4 0.4 0.5 0.5 0.6 0.7 0.8 Lock Up (inches w.c.) C 0.1 0.2 0.2 0.2 0.3 0.3 0.3 0.5 0.7 1.0 Notes: B. Change in outlet pressure for 10 PSIG inlet pressure change. C. Outlet pressure increase required for lock up. *Individual regulator performance may vary from data shown. Inlet pressure is too low to achieve desired outlet pressure. Do not operate orifice in shaded inlet pressure area. Capacity in black outline generated with black spring. 9

7 W.C. RELIEF CURVES B58 Relief Curves 7" w.c. set point 3/4" vent with screen Lever Disconnect Type and Model B58R Inlet Size 3/4" Outlet Size 1" Spring Color Vent Size 3/4" Position 5 Lt. Green Set point 7.0" w.c. with 40 PSIA inlet @ 50 SCFH. All test results are reported at a base of 14.7 PSIA and 60 F. B58 Relief Curves 7" w.c. set point 1" vent with screen Lever Disconnect Type and Model B58R Inlet Size 3/4" Outlet Size 1" Spring Color Vent Size 1" Position 5 Lt. Green Set point 7.0" w.c. with 40 PSIG inlet @ 50 SCFH. All test results are reported at a base of 14.7 PSIA and 60 F. 10

B58 Performance Curves 7" w.c. set point Type and Model B58R Inlet Size 3/4" Outlet Size 1" Spring Color Lt. Green Orifice Size Set point 7.0"w.c. with 40 PSIA inlet @50 SCFH. All test results are reported at a base of 14.7 PSIA and 60 F. 11

B58 SERIES RESIDENTIAL REGULATOR MODELS N AND R 14" w.c. Capacity Table (2" Droop*) 3/4" x 3/4" Valve Body Typical Capacity Info. Inlet Pressure PSIG 1/8" 0.144" x x Capacities in SCFH of 0.6 S.G. gas; base conditions of 14.7 PSIA and 60 F. Orifice Size x 5/16" 5/16" 3/8" 1/2" Type and model B58R 16" w.c. 70 85 115 125 145 340 370 Regulator 21" w.c. 75 90 100 110 145 250 270 350 395 Inlet size 3/4" 24" w.c. 85 100 120 130 165 270 290 375 400 Outlet size 3/4" 1 80 100 115 150 300 320 320 360 400 430 Spring color Silver 2 110 220 230 295 320 380 390 450 530 600 Position: 5 3 210 260 295 375 390 450 465 510 645 660 5 260 360 370 480 500 580 600 620 785 900 1/2" x 9/16" 10 340 475 525 600 680 725 800 840 1120 1200 20 510 685 750 860 900 1000 1010 1100 1200 1380 30 675 825 925 1000 1010 1100 1120 1185 1520 1575 40 800 940 1045 1100 1120 1150 1150 1300 1600 1630 50 900 1050 1200 1220 1230 1250 1250 1400 60 1000 1150 1300 1320 1325 1330 1330 1450 70 1060 1175 1315 1320 1325 80 1130 1225 1340 1340 1340 90 1150 1250 1345 1350 1350 100 1155 1280 1375 1380 1400 120 1240 1300 1400 1410 1450 125 1275 1310 1425 1430 1500 Inlet Effect (inches w.c.) A 0.1 0.2 0.3 0.3 0.3 0.4 0.4 0.5 0.7 1.0 Lock Up (inches w.c.) B 0.3 0.3 0.4 0.4 0.4 0.5 0.5 0.7 0.8 1.1 Notes: A. Change in outlet pressure for 10 PSIG inlet pressure change. B. Outlet pressure increase required for lock up. *Individual regulator performance may vary from data shown. Inlet pressure is too low to achieve desired outlet pressure. Do not operate orifice in shaded inlet pressure area. Capacity in black outline generated with Blue Spring. 12

B58 SERIES RESIDENTIAL REGULATOR MODELS N AND R 14" w.c. Capacity Table (2" Droop*) 3/4" x 1" and 1" x 1" Valve Body Typical Capacity Info. Inlet Pressure PSIG 1/8" 0.144" x x Capacities in SCFH of 0.6 S.G. gas; base conditions of 14.7 PSIA and 60 F. Orifice Size x 5/16" 5/16" 3/8" 1/2" Type and model B58R 16" w.c. 60 65 85 90 100 110 140 275 Regulator 21" w.c. 60 70 85 95 125 200 250 290 350 Inlet size 3/4" 24" w.c. 75 80 100 110 210 220 300 340 410 Outlet size 1" 1 70 85 95 110 250 260 270 300 420 450 Spring color Silver 2 100 225 240 310 330 380 400 490 650 740 Position: 5 3 195 300 310 400 430 490 540 610 845 950 1/2" x 9/16" 5 230 395 400 510 590 660 770 850 985 1235 10 350 550 600 775 940 970 1210 1250 1390 1645 20 500 800 1010 1220 1510 1540 1820 1850 2080 2120 30 700 1035 1375 1550 1980 2000 2150 2170 2260 2130 40 925 1260 1830 1870 2200 2230 2445 2420 2500 2215 50 1130 1410 2070 2080 2500 2440 2500 2500 60 1250 1600 2300 2350 2500 2500 2500 2500 70 1410 1775 2500 2475 2500 2500 2500 80 1560 1960 2500 2500 2500 2500 2500 90 1710 2000 2500 2500 2500 2500 2500 100 1900 2240 2500 2500 2500 2500 2500 120 2265 2300 2500 2500 2500 125 2315 2345 2500 2500 2500 Inlet Effect (inches w.c.) A 0.1 0.2 0.2 0.3 0.4 0.4 0.5 0.5 0.6 1.0 Lock Up (inches w.c.) B 0.3 0.3 0.4 0.4 0.4 0.5 0.5 0.7 0.8 1.1 Notes: A. Change in outlet pressure for 10 PSIG inlet pressure change. B. Outlet pressure increase required for lock up. *Individual regulator performance may vary from data shown. Inlet pressure is too low to achieve desired outlet pressure. Do not operate orifice in shaded inlet pressure area. Capacity in black outline generated with Blue Spring. Capacity in grey outline generated with Yellow Spring 13

B58 SERIES RESIDENTIAL REGULATOR MODELS N AND R 14" w.c. Capacity Table (2" Droop*) 3/4" x 1-, 1" x 1- and 1- x 1- Valve Body Typical Capacity Info. Inlet Pressure PSIG 1/8" 0.144" x Capacities in SCFH of 0.6 S.G. gas; base conditions of 14.7 PSIA and 60 F. x Orifice Size x 5/16" 5/16" 3/8" 1/2" Type and model B58R 16" w.c. 65 70 80 100 120 200 370 420 Regulator 21" w.c. 70 80 180 200 225 250 300 400 450 Inlet size 1-24" w.c. 80 90 200 210 250 300 340 450 520 Outlet size 1-1 60 90 110 240 300 330 360 400 600 650 Spring color Silver 2 80 250 275 400 400 500 550 600 900 1100 Position 5 3 120 320 350 500 600 700 750 900 1250 1300 1/2" x 9/16" 5 250 420 500 650 750 1000 1080 1250 1700 1800 10 400 550 800 900 1250 1500 1700 2000 2500 2500 20 550 800 1250 1290 2150 2180 2500 2500 2500 2500 30 750 1000 1600 1650 2500 2500 2500 2500 2500 2500 40 900 1250 2000 2030 2500 2500 2500 2500 2500 2500 50 1000 1500 2300 2350 2500 2500 2500 2500 60 1250 1700 2500 2500 2500 2500 2500 2500 70 1400 1950 2500 2500 2500 2500 2500 80 1500 2150 2500 2500 2500 2500 2500 90 1700 2375 2500 2500 2500 2500 2500 100 1900 2500 2500 2500 2500 2500 2500 120 2250 2500 2500 2500 2500 125 2325 2500 2500 2500 2500 Inlet Effect (inches w.c.) A 0.4 0.4 0.4 0.5 0.5 0.6 0.6 0.7 0.9 1.0 Lock Up (inches w.c.) B 0.2 0.3 0.3 0.4 0.4 0.5 0.5 0.5 1.0 1.0 Notes: A. Change in outlet pressure for 10 PSIG inlet pressure change. B. Outlet pressure increase required for lock up. *Individual regulator performance may vary from data shown. Inlet pressure is too low to achieve desired outlet pressure. Do not operate orifice in shaded inlet pressure area. Capacity in black outline generated with Red/grey Spring 14

B58 Relief Curves 14" w.c. set point - 3/4" vent with screen Lever Disconnect Type and Model B58R Inlet Size 3/4" Outlet Size 1" Spring Color Silver Vent Size 3/4" Position 5 Set point 7.0" w.c. with 40 PSIG inlet @ 50 SCFH. All test results are reported at a base of 14.7 PSIA and 60 F. B58 Relief Curves 14" w.c. set point - 1" vent with screen Lever Disconnect Type and Model B58R Inlet Size 3/4" Outlet Size 1" Spring Color Vent Size 1" Position 5 Silver Set point 7.0" w.c. with 40 PSIG inlet @ 50 SCFH. All test results are reported at a base of 14.7 PSIA and 60 F. 15

B58 Performance Curves 14" w.c. set point Type and Model B58R Inlet Size 3/4" Outlet Size 1" Spring Color Silver Orifice Size Set point 7.0" w.c. with 40 PSIA inlet @ 50 SCFH. All test results are reported at a base of 14.7 PSIA and 60 F. 16

B58 SERIES RESIDENTIAL REGULATOR MODELS N AND R 1 PSIG Capacity Table (1% Absolute Droop*) 3/4" x 3/4" Valve Body Typical Capacity Info. Inlet Pressure PSIG 1/8" 0.144" x Capacities in SCFH of 0.6 S.G. gas; base conditions of 14.7 PSIA and 60 F. x Orifice Size x 5/16" 5/16" 3/8" 1/2" Type and model B58RHP 2 75 180 225 240 250 275 285 300 400 450 Regulator 3 180 230 250 300 310 350 360 400 520 600 Inlet size 3/4" 5 220 300 310 410 415 450 475 510 630 725 Outlet size 3/4" 10 300 420 450 525 550 600 650 700 875 940 Spring color Red/Grey 20 450 600 625 780 800 825 880 935 995 1100 Position 5 30 525 780 840 950 960 990 1000 1100 1180 1170 1/2" x 9/16" 40 690 875 940 1050 1060 1100 1110 1145 1200 1200 50 760 950 1000 1100 1150 1150 1160 1200 60 850 1000 1180 1200 1225 1275 1280 1300 70 950 1100 1200 1275 1300 1320 1340 80 975 1125 1285 1310 1390 1400 1400 90 1000 1200 1300 1320 1400 1400 1420 100 1100 1225 1325 1400 1425 1425 120 1200 1250 1420 1435 1450 125 1225 1300 1440 1470 1490 Inlet Effect (PSIG) A 0.01 0.01 0.02 0.02 0.02 0.02 0.03 0.04 0.05 0.06 Lock Up (PSIG) B 0.05 0.05 0.05 0.06 0.06 0.07 0.07 0.08 0.09 0.08 Notes: A. Change in outlet pressure for 10 PSIG inlet pressure change. B. Outlet pressure increase required for lock up. *Individual regulator performance may vary from data shown. Do not operate orifice in shaded inlet pressure area. 17

1 PSIG Capacity Table (2% Absolute Droop*) 3/4" x 3/4" Valve Body Inlet Pressure PSIG 1/8" 0.144" x x Capacities in SCFH of 0.6 S.G. gas; base conditions of 14.7 PSIA and 60 F. Orifice Size x 5/16" 5/16" 3/8" 1/2" 2 80 230 300 350 400 440 490 520 700 820 1/2" x 9/16" 3 200 310 360 430 500 560 585 680 900 1000 5 275 425 450 600 635 800 825 900 1100 1200 10 400 550 700 850 930 1080 1100 1275 1450 1550 20 600 800 1000 1200 1300 1400 1500 1660 1800 1890 30 760 1000 1300 1450 1550 1650 1700 1800 2100 2115 40 950 1200 1500 1650 1700 1835 1880 1990 2110 2120 50 1100 1480 1725 1800 1900 1975 2000 2050 60 1200 1600 1900 1975 2000 2080 2100 2165 70 1400 1700 2000 2050 2100 2160 2200 80 1500 1800 2100 2075 2150 2200 2300 90 1600 1850 2125 2125 2150 2230 2325 100 1700 1900 2150 2175 2200 2240 2360 120 1900 1950 2200 2225 2225 125 1950 1975 2225 2250 2250 Inlet Effect (PSIG) A 0.01 0.01 0.02 0.02 0.02 0.02 0.03 0.04 0.05 0.06 Lock Up (PSIG) B 0.05 0.05 0.05 0.06 0.06 0.07 0.07 0.08 0.09 0.08 Notes: A. Change in outlet pressure for 10 PSIG inlet pressure change. B. Outlet pressure increase required for lock up. *Individual regulator performance may vary from data shown. Do not operate orifice in shaded inlet pressure area. 18

B58 SERIES RESIDENTIAL REGULATOR MODELS N AND R 1 PSIG Capacity Table (1% Absolute Droop*) 3/4" x 1" and 1" x 1" Valve Bodies Typical Capacity Info. Inlet Pressure PSIG 1/8" 0.144" x Capacities in SCFH of 0.6 S.G. gas; base conditions of 14.7 PSIA and 60 F. x Orifice Size x 5/16" 5/16" 3/8" 1/2" Type and model B58RHP 2 75 85 220 230 260 290 300 325 440 490 Regulator 3 100 230 270 310 330 370 390 420 575 650 Inlet size 3/4" 5 215 325 340 420 440 490 500 590 810 950 Outlet size 1" 10 300 450 470 625 650 715 740 920 1250 1400 Spring color Red/Grey 20 495 675 750 980 1075 1120 1250 1425 1820 1990 Position: 5 30 630 880 1025 1270 1480 1510 1740 1790 2280 2460 1/2" x 9/16" 40 790 1060 1310 1640 1830 1975 2050 2115 2500 2500 50 925 1235 1665 1945 2200 2060 2330 2315 60 1140 1415 1935 2160 2360 2280 2500 2425 70 1230 1645 2205 2390 2500 2400 2500 80 1330 1720 2445 2500 2500 2500 2500 90 1555 1750 2500 2500 2500 2500 2500 100 1750 2035 2500 2500 2500 2500 2500 120 2075 2160 2500 2500 2500 125 2100 2200 2500 2500 2500 Inlet Effect (PSIG) A 0.01 0.01 0.02 0.02 0.02 0.02 0.03 0.03 0.05 0.06 Lock Up (PSIG) B 0.05 0.05 0.05 0.05 0.05 0.06 0.06 0.07 0.09 0.09 Notes: A. Change in outlet pressure for 10 PSIG inlet pressure change. B. Outlet pressure increase required for lock up. *Individual regulator performance may vary from data shown. Do not operate orifice in shaded inlet pressure area. 19

1 PSIG Capacity Table (2% Absolute Droop*) 3/4" x 1" and 1" x 1" Valve Body Inlet Pressure PSIG 1/8" 0.144" x x Capacities in SCFH of 0.6 S.G. gas; base conditions of 14.7 PSIA and 60 F. Orifice Size x 5/16" 5/16" 3/8" 1/2" 2 85 230 320 365 420 490 530 590 800 900 1/2" x 9/16" 3 200 325 390 460 520 630 670 775 1035 1180 5 280 430 510 610 700 850 880 1060 1400 1585 10 375 580 720 895 1050 1275 1330 1560 1980 2200 20 580 800 1170 1275 1700 1950 2050 2285 2500 2500 30 770 1030 1590 1610 2240 2385 2500 2500 2500 2500 40 955 1255 1950 1980 2500 2500 2500 2500 2500 2500 50 1125 1475 2330 2275 2500 2500 2500 2500 60 1220 1710 2500 2500 2500 2500 2500 2500 70 1420 1965 2500 2500 2500 2500 2500 80 1580 2190 2500 2500 2500 2500 2500 90 1725 2385 2500 2500 2500 2500 2500 100 1885 2500 2500 2500 2500 2500 2500 120 2225 2500 2500 2500 2500 125 2300 2500 2500 2500 2500 Inlet Effect (PSIG) A 0.01 0.01 0.02 0.02 0.02 0.02 0.03 0.03 0.05 0.06 Lock Up (PSIG) B 0.05 0.05 0.05 0.05 0.05 0.06 0.06 0.07 0.09 0.09 Notes: A. Change in outlet pressure for 10 PSIG inlet pressure change. B. Outlet pressure increase required for lock up. *Individual regulator performance may vary from data shown. Do not operate orifice in shaded inlet pressure area. 20

B58 SERIES RESIDENTIAL REGULATOR MODELS N AND R 1 PSIG Capacity Table (1% Absolute Droop*) 3/4" x 1-, 1" x 1- and 1- x 1- Valve Bodies Typical Capacity Info. Inlet Pressure PSIG 1/8" 0.144" x Capacities in SCFH of 0.6 S.G. gas; base conditions of 14.7 PSIA and 60 F. x Orifice Size x 5/16" 5/16" 3/8" 1/2" Type and model B58RHP 2 100 190 230 300 320 400 420 450 640 730 Regulator 3 210 230 240 400 420 520 540 600 820 1000 Inlet size 1-5 250 400 450 550 580 700 730 850 1100 1400 Outlet size 1-10 350 550 650 850 880 1150 1200 1450 1750 2250 Spring color Red/Grey 20 550 800 1100 1250 1400 1900 2000 2400 2500 2500 Position 5 30 700 1020 1400 1600 2100 2500 2500 2500 2500 2500 1/2" x 9/16" 40 900 1250 1800 2000 2500 2500 2500 2500 2500 2500 50 1100 1500 2300 2300 2500 2500 2500 2500 60 1250 1720 2500 2500 2500 2500 2500 2500 70 1400 1960 2500 2500 2500 2500 2500 80 1580 2150 2500 2500 2500 2500 2500 90 1720 2300 2500 2500 2500 2500 2500 100 1900 2500 2500 2500 2500 2500 2500 120 2250 2500 2500 2500 2500 125 2350 2500 2500 2500 2500 Inlet Effect (PSIG) A 0.01 0.01 0.01 0.02 0.02 0.03 0.03 0.03 0.04 0.06 Lock Up (PSIG) B 0.03 0.04 0.04 0.05 0.04 0.04 0.05 0.05 0.05 0.05 Notes: A. Change in outlet pressure for 10 PSIG inlet pressure change. B. Outlet pressure increase required for lock up. *Individual regulator performance may vary from data shown. Do not operate orifice in shaded inlet pressure area. Capacity in black line generated with Yellow Spring. 21

1 PSIG Capacity Table (2% Absolute Droop*) 3/4" x 1-, 1" x 1- and 1- x 1- Valve Bodies Inlet Pressure PSIG 1/8" 0.144" x x Capacities in SCFH of 0.6 S.G. gas; base conditions of 14.7 PSIA and 60 F. Orifice Size x 5/16" 5/16" 3/8" 1/2" 1/2" x 9/16" 2 110 250 330 350 480 620 650 750 1000 1300 3 220 340 400 500 600 800 850 1030 1400 1750 5 270 430 550 650 850 1100 1200 1450 1950 2400 10 400 560 850 900 1350 1600 1950 2250 2500 2500 20 580 810 1200 1280 2100 2300 2500 2500 2500 2500 30 750 1050 1600 1650 2500 2500 2500 2500 2500 2500 40 920 1280 1900 2000 2500 2500 2500 2500 2500 2500 50 1110 1500 2300 2350 2500 2500 2500 2500 60 1260 1730 2500 2500 2500 2500 2500 2500 70 1420 1960 2500 2500 2500 2500 2500 80 1590 2170 2500 2500 2500 2500 2500 90 1730 2350 2500 2500 2500 2500 2500 100 1920 2500 2500 2500 2500 2500 2500 120 2260 2500 2500 2500 2500 125 2375 2500 2500 2500 2500 Inlet Effect (PSIG) A 0.01 0.01 0.01 0.02 0.02 0.03 0.03 0.03 0.04 0.06 Lock Up (PSIG) B 0.03 0.04 0.04 0.05 0.04 0.04 0.05 0.05 0.05 0.05 Notes: A. Change in outlet pressure for 10 PSIG inlet pressure change. B. Outlet pressure increase required for lock up. *Individual regulator performance may vary from data shown. Do not operate orifice in shaded inlet pressure area. Capacity in black line generated with Yellow Spring. 22

1 PSIG RELIEF CURVES B58 Relief Curves 1 PSIG set point 3/4" vent with screen Lever Disconnect Type and Model B58RHP Inlet Size 3/4" Outlet Size 1" Spring Color Vent Size 3/4" Position 5 Red/Grey Set point 7.0" w.c. with 40 PSIG inlet @ 50 SCFH. All test results are reported at a base of 14.7 PSIA and 60 F. B58 Relief Curves 1 PSIG set point 1" vent with screen Lever Disconnect Type and Model B58RHP Inlet Size 3/4" Outlet Size 1" Spring Color Vent Size 1" Position 5 Red/Grey Set point 7.0" w.c. with 40 PSIG inlet @ 50 SCFH. All test results are reported at a base of 14.7 PSIA and 60 F. 23

B58 Performance Curves 1 PSIG set point Type and Model B58RHP Inlet Size 3/4" Outlet Size 1" Spring Color Red/Grey Orifice Size Set point 7.0" w.c. with 40 PSIG inlet @ 50 SCFH. All test results are reported at a base of 14.7 PSIA and 60 F. 24

B58 SERIES RESIDENTIAL REGULATOR MODELS N AND R 2 PSIG Capacity Table (1% Absolute Droop*) 3/4" x 3/4" Valve Body Typical Capacity Info. Inlet Pressure PSIG 1/8" 0.144" x Capacities in SCFH of 0.6 S.G. gas; base conditions of 14.7 PSIA and 60 F. x Orifice Size x 5/16" 5/16" 3/8" 1/2" Type and model B58RHP 3 65 75 180 200 220 220 220 240 270 310 Regulator 5 85 200 200 260 290 310 310 330 400 450 Inlet size 3/4" 10 220 300 300 410 420 420 430 460 625 650 Outlet size 3/4" 20 320 375 475 550 550 600 600 750 775 780 Spring color Red 30 400 500 550 600 610 750 750 760 800 795 Position 5 40 525 550 650 710 720 775 800 840 825 835 50 545 640 675 800 810 825 840 890 60 600 775 800 850 880 900 900 950 70 650 830 900 1000 1000 1000 1000 80 730 840 950 940 1000 1050 1050 90 775 895 975 950 1020 1100 1100 100 830 945 1025 1100 1100 1200 1200 120 1000 1005 1090 1125 1150 125 1010 1030 1060 1135 1175 1/2" x 9/16" Inlet Effect (PSIG) A 0.02 0.03 0.03 0.03 0.03 0.04 0.06 0.06 0.07 0.09 Lock Up(PSIG) B 0.08 0.08 0.09 0.09 0.09 0.10 0.11 0.12 0.12 0.12 Notes: A. Change in outlet pressure for 10 PSIG inlet pressure change. B. Outlet pressure increase required for lock up. *Individual regulator performance may vary from data shown. Do not operate orifice in shaded inlet pressure area. 25

2 PSIG Capacity Table (2% Absolute Droop*) 3/4" x 3/4" Valve Body Inlet Pressure PSIG 1/8" 0.144" x Capacities in SCFH of 0.6 S.G. gas; base conditions of 14.7 PSIA and 60 F. x Orifice Size x 5/16" 5/16" 3/8" 1/2" 3 85 90 300 300 325 350 340 410 450 620 5 220 330 325 420 430 525 530 600 675 880 1/2" x 9/16" 10 330 485 510 650 680 725 785 800 1100 1280 20 520 700 770 975 990 1000 1000 1300 1500 1700 30 700 850 950 1100 1100 1300 1300 1600 1700 1910 40 840 1000 1100 1250 1260 1500 1540 1700 1775 2000 50 900 1100 1200 1450 1450 1750 1750 1900 60 1000 1300 1400 1560 1650 1900 1920 2000 70 1100 1400 1500 1800 1900 1925 1970 80 1200 1600 1650 1850 1950 1950 1950 90 1280 1700 1700 1900 1975 2000 2000 100 1400 1800 1800 200 1980 2000 2000 120 1550 1850 1800 2050 2100 125 1600 1875 1900 2075 2110 Inlet Effect (PSIG) A 0.02 0.03 0.03 0.03 0.03 0.04 0.06 0.06 0.07 0.09 Lock Up(PSIG) B 0.08 0.08 0.09 0.09 0.09 0.10 0.11 0.12 0.12 0.12 Notes: A. Change in outlet pressure for 10 PSIG inlet pressure change. B. Outlet pressure increase required for lock up. *Individual regulator performance may vary from data shown. Do not operate orifice in shaded inlet pressure area. 26

B58 SERIES RESIDENTIAL REGULATOR MODELS N AND R 2 PSIG Capacity Table (1% Absolute Droop*) 3/4" x 1" and 1" x 1" Valve Bodies Typical Capacity Info. Inlet Pressure PSIG 1/8" 0.144" x Capacities in SCFH of 0.6 S.G. gas; base conditions of 14.7 PSIA and 60 F. x Orifice Size x 5/16" 5/16" 3/8" 1/2" Type and model B58RHP 3 75 95 190 210 220 230 240 250 290 340 Regulator 5 100 200 210 300 275 310 320 340 450 500 Inlet size 3/4" 10 205 290 300 400 420 470 535 550 575 680 Outlet size 1" 20 340 450 500 640 660 680 700 720 1020 1110 Spring color Red 30 445 585 650 850 880 900 920 1030 1150 1325 Position 5 40 530 710 790 950 990 1020 1040 1200 1410 1460 50 620 815 990 1100 1130 1150 1290 1595 60 725 920 1090 1250 1280 1350 1530 1625 70 825 1050 1240 1500 1530 1680 1740 80 900 1150 1450 1500 1715 1780 1855 90 980 1180 1620 1820 1950 1980 1990 100 1125 1230 1715 1950 1975 2000 2020 120 1255 1400 1870 2275 2350 125 1295 1425 1900 2340 2460 1/2" x 9/16" Inlet Effect (PSIG) A 0.02 0.03 0.03 0.03 0.03 0.04 0.05 0.06 0.08 0.09 Lock Up(PSIG) B 0.06 0.06 0.06 0.06 0.06 0.07 0.07 0.07 0.07 0.11 Notes: A. Change in outlet pressure for 10 PSIG inlet pressure change. B. Outlet pressure increase required for lock up. *Individual regulator performance may vary from data shown. Do not operate orifice in shaded inlet pressure area. Capacity in black outline generated with White Spring. 27

2 PSIG Capacity Table (2% Absolute Droop*) 3/4" x 1" and 1" x 1" Valve Bodies Inlet Pressure PSIG 1/8" 0.144" x Capacities in SCFH of 0.6 S.G. gas; base conditions of 14.7 PSIA and 60 F. x Orifice Size x 5/16" 5/16" 3/8" 1/2" 3 85 250 270 300 350 370 390 440 550 640 5 210 330 350 440 460 520 550 620 840 990 1/2" x 9/16" 10 320 520 525 700 720 850 900 1030 1210 1410 20 510 750 850 1140 1170 1300 1350 1425 1980 2030 30 690 1000 1150 1550 1610 1760 1800 1930 2460 2500 40 870 1250 1475 1900 1930 2085 2110 2300 2500 2500 50 1020 1450 1785 2210 2230 2285 2410 2500 60 1200 1675 2025 2475 2500 2500 2500 2500 70 1400 1880 2240 2500 2500 2500 2500 80 1525 2065 2500 2500 2500 2500 2500 90 1675 2175 2500 2500 2500 2500 2500 100 1860 2375 2500 2500 2500 2500 120 2185 2500 2500 2500 2500 125 2230 2500 2500 2500 2500 Inlet Effect (PSIG) A 0.02 0.03 0.03 0.03 0.03 0.04 0.05 0.06 0.08 0.09 Lock Up(PSIG) B 0.06 0.06 0.06 0.06 0.06 0.07 0.07 0.07 0.07 0.11 Notes: A. Change in outlet pressure for 10 PSIG inlet pressure change. B. Outlet pressure increase required for lock up. *Individual regulator performance may vary from data shown. Do not operate orifice in shaded inlet pressure area. Capacity in black outline generated with White Spring. 28

B58 SERIES RESIDENTIAL REGULATOR MODELS N AND R 2 PSIG Capacity Table (1% Absolute Droop*) 3/4" x 1-, 1" x 1- and 1- x 1- Valve Bodies Typical Capacity Info. Inlet Pressure PSIG 1/8" 0.144" x Capacities in SCFH of 0.6 S.G. gas; base conditions of 14.7 PSIA and 60 F. x Orifice Size x 5/16" 5/16" 3/8" 1/2" Type and model B58RHP 3 75 115 225 230 240 255 270 320 410 410 Regulator 5 120 230 250 355 365 435 450 510 580 590 Inlet size 1-10 290 365 400 580 580 600 610 690 960 1160 Outlet size 1-20 435 610 660 920 930 950 970 1220 1755 2060 Spring color Red 30 610 825 860 1200 1210 1260 1350 1750 2500 2500 Position 5 40 735 900 1100 1460 1470 1775 1820 2280 2500 2500 50 875 1085 1310 1730 1910 2350 2500 2500 60 1030 1360 1700 2200 2225 2500 2500 2500 70 1150 1540 2010 2500 2500 2500 2500 80 1285 1635 2280 2500 2500 2500 2500 90 1365 1960 2500 2500 2500 2500 2500 100 1485 2190 2500 2500 2500 2500 2500 120 1970 2500 2500 2500 2500 125 2080 2500 2500 2500 2500 1/2" x 9/16" Inlet Effect (PSIG) A 0.02 0.02 0.02 0.03 0.03 0.04 0.04 0.04 0.05 0.07 Lock Up(PSIG) B 0.05 0.05 0.05 0.05 0.05 0.06 0.07 0.07 0.07 0.07 Notes: A. Change in outlet pressure for 10 PSIG inlet pressure change. B. Outlet pressure increase required for lock up. *Individual regulator performance may vary from data shown. Do not operate orifice in shaded inlet pressure area. 29

2 PSIG Capacity Table (2% Absolute Droop*) 3/4" x 1-, 1" x 1- and 1- x 1- Valve Bodies Inlet Pressure PSIG 1/8" 0.144" x x Capacities in SCFH of 0.6 S.G. gas; base conditions of 14.7 PSIA and 60 F. Orifice Size x 5/16" 5/16" 3/8" 1/2" 3 95 240 310 375 380 460 480 550 770 810 1/2" x 9/16" 5 215 300 390 560 570 740 760 860 1120 1300 10 380 530 660 880 940 1150 1170 1400 1820 2100 20 590 775 1085 1250 1550 1890 1920 2325 2500 2500 30 780 1000 1495 1610 2080 2500 2500 2500 2500 2500 40 965 1240 1850 2000 2500 2500 2500 2500 2500 2500 50 1145 1450 2250 2300 2500 2500 2500 2500 60 1320 1695 2500 2500 2500 2500 2500 2500 70 1480 1950 2500 2500 2500 2500 2500 80 1680 2160 2500 2500 2500 2500 2500 90 1815 2365 2500 2500 2500 2500 2500 100 2015 2485 2500 2500 2500 2500 120 2360 2500 2500 2500 2500 125 2500 2500 2500 2500 2500 Inlet Effect (PSIG) A 0.02 0.02 0.02 0.03 0.03 0.04 0.04 0.04 0.05 0.07 Lock Up(PSIG) B 0.05 0.05 0.05 0.05 0.05 0.06 0.07 0.07 0.07 0.07 Notes: A. Change in outlet pressure for 10 PSIG inlet pressure change. B. Outlet pressure increase required for lock up. *Individual regulator performance may vary from data shown. Do not operate orifice in shaded inlet pressure area. 30

2 PSIG RELIEF CURVES B58 Relief Curves 2 PSIG set point 3/4" vent with screen Lever Disconnect Type and Model B58RHP Inlet Size 3/4" Outlet Size 1" Spring Color Red Vent Size 3/4" Position 5 Set point 7.0" w.c. with 40 PSIG inlet @ 50 SCFH. All test results are reported at a base of 14.7 PSIA and 60 F. B58 Relief Curves 2 PSIG set point 1" vent with screen Lever Disconnect Type and Model B58RHP Inlet Size 3/4" Outlet Size 1" Spring Color Vent Size 1" Position 5 Red Set point 7.0" w.c. with 40 PSIG inlet @ 50 SCFH. All test results are reported at a base of 14.7 PSIA and 60 F. 31

B58 Performance Curves 2 PSIG set point Type and Model Inlet Size 3/4" Outlet Size 1" Spring Color B58RHP Red Orifice Size Set point 7.0" w.c. with 40 PSIG inlet @ 50 SCFH. All test results are reported at a base of 14.7 PSIA and 60 F. 32

ASSEMBLY POSITIONS 33

B58 PARTS DIAGRAM B58 Parts List Item No. Part No. Quantity Required per Regulator Model N R HP Description 1 010323 8 8 8 Case Screw (Hex Head) 1/4-20 x 3/4 2 720075 1 1 Diaphragm Assembly -R 720077 1 1 Diaphragm Assembly -N 4 1 1 1 Valve Body - Straight - Specify Size 750410 1/2" x 1/2" 750411 3/4" x 3/4" 750414 3/4" x 1" 750412 3/4" x 1-750413 1" x 1" 750416 1" x 1-750415 1- x 1-6 1 1 1 Lower Diaphragm Case Assembly 715096 5.5:1 Ratio - 3/4" and 1" valve bodies 715095 4:1 Ratio - 1- valve bodies 34

Item No. Part No. Quantity Required per Regulator Model N R HP Description 7 Upper Diaphragm Case 753189 1 1 Vent - 3/4" Pipe 753190 1 Vent - 3/4" Pipe -HP 753250 1 1 Vent - 1" Pipe 753251 1 Vent - 1" Pipe -HP 8 75483401 1 1 1 Vent Valve 1" Pin 9 755378 2 2 2 Valve Body Screw 10 1 1 1 Orifice - Aluminum (Specify Size) 757213 1/8" Diameter 757313 0.144" x Diameter 757219 Diameter 757331 x Diameter 757225 Diameter 757337 x 5/16" Diameter 757231 5/16" Diameter 757237 3/8" Diameter 757451 1/2" Diameter 75747401 1/2" x 9/16" Diameter 11 760058 1 1 1 Seal Cap 12 760215 1 1 Adjustment Ferrule - Celcon 760217 1 Adjustment Ferrule - Aluminum 13 761245 1 1 1 Valve Stem 14 761715 1 1 1 Deflector Ring 15 761753 1 1 1 Loading Ring 16 1 1 Adjustment Spring 762111 Brown 762117 Dark Green 762139 Grey 762119 Light Green 762123 Black 762127 Blue 762129 Silver 1 HP Adjustment Spring 762025 Red/Grey 762131 Yellow 762135 Red 762137 White 35

Item No. Part No. Quantity Required per Regulator Model N R HP Description 17 762651 1 1 1 Vent Spring 18 762933 1 1 1 Vent Valve Screen; 1" and 3/4" Vent 19 765011 1 1 1 Buna-N Valve Seat 765012 1 1 1 Silicone Valve Seat 20 1 1 1 Valve Stem Insert Assembly 765155 4:1 Lever Ratio - 1- Valve Bodies 765156 5.5:1 Lever Ratio - 3/4" & 1" Valve Bodies 22 765193 1 1 1 Vent Valve Disc 23 765503 1 1 1 Seal Cap "O" Ring 24 765605 1 1 1 Valve Body Gasket 25 765685 1 1 1 Vent Valve Seat 26 769250 1 1 1 Regulator Badge(s) Case Screws Valve Body Screws Orifice Torque Specifications 27-30 in. lbs. 85-115 in. lbs. 450-500 in. lbs. Special Tools 799051 Spring Adjustment Wrench 799017 Orifice Socket 36

VENT LINES FOR REGULATORS When constructing vent lines to be attached to regulators installed indoors, follow a few basic rules: a. Never use pipe sizes smaller than the vent size; smaller pipe sizes restrict the gas flow. If a long gas run must be used, advises increasing the pipe one nominal size every ten feet to keep the flow restriction as low as possible. b. Keep the vent line length as short as possible to minimize the restriction and reduce the vent's tendency to cause regulator pulsation. c. Support the vent pipe to eliminate strain on the regulator diaphragm case. d. Always point outdoor vent pipes in the downward position to reduce the possibility of rain, snow, sleet, and other moisture entering the pipe. Install a bug screen in the end of the pipe. e. Do not locate the vent line terminus near windows, fans, or other ventilation equipment. See the installation instructions furnished with the regulator. f. Adhere to all applicable codes and regulations. g. If your vent pipe causes regulator pulsation, consult your sales representative or manufacturer. h. strongly recommends running a separate vent line for each regulator. Headers with various installed devices can cause regulator malfunction. Caution Ensure the end of the vent line is away from ANY potential ignition sources. It is the installer s responsibility to ensure the vent line is exhausting to a safe environment. INSTALLATION Warning does not endorse or warrant the completeness or accuracy of any third party regulator installation procedures or practices, unless otherwise provided in writing by. Follow your company's standard operating procedures regarding the use of personal protection equipment (PPE). Adhere to guidelines issued by your company in addition to those given in this document when installing regulators. a. Remove all shipping plugs from the regulator inlet, outlet, and vent before installation. b. Verify the piping interior and regulator inlet and outlet are clean and free of dirt, pipe dope, and other debris. Dirt and other foreign materials entering the regulator can cause a loss of pressure control. c. Apply pipe joint sealant to the male pipe threads. Do not use pipe joint material on the regulator's female threads. Joint sealant could become lodged in the regulator and cause a loss of pressure control. d. Gas must flow through the regulator's valve body in the direction cast on the regulator body. Gas flowing in the wrong direction can overpressure and cause damage to the regulator. e. For the B42, B31, B58, B34, and B34S models, the diaphragm casing can be mounted in any position relative to the body through a full 360 angle at 90 increments. B57, B34, and B38 models can be mounted in a full 360 angle. f. When the regulator is installed OUTDOORS, the vent must always be positioned so that rain, snow, moisture or foreign particles cannot enter the vent opening. It is recommended that the vent be positioned to face downward so as to avoid entry of water or other matter which could interfere with the proper operation of the regulator. The vent should be located away from building eves, window openings, building air intakes and above the expected snow level at the site. The vent opening should be inspected periodically to insure it does not become blocked by foreign material as outlined in DOT PHMSA-RSPA-2004-19856. g. When the regulator is installed INDOORS, the vent must be piped to the outside atmosphere while using the shortest length of pipe, the least number of elbows, and having as large a pipe diameter as the vent size or larger. USING VENT PIPE ANY SIZE SMALLER THAN THE VENT CONNECTION WILL LIMIT THE REGULATOR S INTERNAL RELIEF VALVE CAPACITY. The outlet end of the pipe must be protected from moisture and the entrance of foreign particles. The regulator should be specified by the user with the size vent and pipe threads desired to make the vent pipe connection. 37

START-UP PROCEDURE a. Mount a pressure gauge downstream of the regulator to monitor the downstream pressure. b. With the downstream pressure valve closed, slowly open the inlet valve. The outlet pressure should rise to slightly more than the set-point. c. Verify there are no leaks and all connections are tight. d. The regulator was pre-set at the factory to match order specifications. If necessary, adjust the outlet pressure by removing the seal cap on the top of the spring housing and rotating the ferrule or adjustment screw inside the spring housing. Adjusting the outlet pressure requires either a ratchet with a socket and an extension or a large flat-head screwdriver. With a small amount of gas flowing through the regulator: e. Rotate the adjustment screw clockwise to raise the outlet pressure. f. Rotate the adjustment screw counter-clockwise to lower the outlet pressure. g. Replace the seal cap and check for leaks after the desired outlet pressure is achieved. The regulator is ready for operation. SAFETY WARNING This product, as of the date of manufacture, is designed and tested to conform to all governmental and industry safety standards as they may apply to the manufacturer. The purchaser/user of this product must comply with all fire control, building codes, and other safety regulations governing the application, installation, operation, and general use of this regulator to avoid leaking gas hazards resulting from improper installation, startup or use of this product. strongly recommends installation by a qualified professional and periodic inspection of pressure regulators (inspections may be required by local applicable codes or regulations). Inspections should include checking for gas quality, cycle numbers, external environmental changes, and operating conditions that impact wear on the regulator's moving parts. To ensure safe and efficient operation of this product, replace worn or damaged parts found during inspection. 38

Limited Warranty, Inc. 970 Highway 127 North, Owenton, Kentucky 40359-9302, warrants this gas product against defects in materials and workmanship for the earlier of one (1) year from the date the product is shipped by or a period of one year from the date the product is installed by at the original purchaser s site. During such one-year period, provided that the original purchaser continues to own the product, will, at its sole option, repair any defects, replace the product or repay the purchase price. This warranty will be void if the purchaser fails to observe the procedures for installation, operation or service of the product as set forth in the Operating Manual and Specifications for the product or if the defect is caused by tampering, physical abuse or misuse of the product. ITRON SPECIFICALLY DISCLAIMS ALL IMPLIED WARRANTIES INCLUDING THOSE OF MERCHANTABILITY OR OF FITNESS FOR A PARTICULAR PURPOSE. UNDER NO CIRCUMSTANCES WILL ITRON BE LIABLE FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES OF ANY KIND WHATSOEVER. s liability for any claim of any kind, including negligence and breach of warranty for the sale and use of any product covered by or furnished, shall in no case exceed the price allocable to the product or part thereof which gives rise to the claim. In the event of a malfunction of the product, consult your Service Representative or Inc., 970 Highway 127 North, Owenton, Kentucky 40359-9302. See Terms and Conditions of Sale for the full and complete terms of the Limited Warranty. Ordering Information 1. Inlet and outlet connection size and type 2. Model number 3. Outlet pressure desired 4. Inlet pressure range 5. Type of gas and maximum capacity required 6. Assembly position number (see diagram above) 7. Vent size 8. Special requirements such as tagging, pipe plug tap, seal wire, etc. is the world s leading provider of smart metering, data collection and utility software systems, with over 8,000 utilities worldwide relying on our solutions to responsibly and efficiently manage the delivery and use of energy and water. To realize your smarter energy and water future, start here: www.itron.com ITRON Gas 970 Highway 127 North Owenton, Kentucky 40359 USA Phone: 1.800.490.0657 Fax: 1.502.484.6223 corporate headquarters 2111 N Molter Road Liberty Lake, WA 99019 USA Phone: 1.800.635.5461 Fax: 1.509.891.3355 While strives to make the content of its marketing materials as timely and accurate as possible, makes no claims, promises, or guarantees about the accuracy, completeness, or adequacy of, and expressly disclaims liability for errors and omissions in, such materials. No warranty of any kind, implied, expressed, or statutory, including but not limited to the warranties of non-infringement of third party rights, title, merchantability, and fitness for a particular purpose, is given with respect to the content of these marketing materials. Copyright 2011,. All rights reserved. 100972SP-02-08/11