FAULT ANALYSIS OF AN ISLANDED MICRO-GRID WITH DOUBLY FED INDUCTION GENERATOR BASED WIND TURBINE

Similar documents
Journal of American Science 2015;11(11) Integration of wind Power Plant on Electrical grid based on PSS/E

Statcom Operation for Wind Power Generator with Improved Transient Stability

Battery Energy Storage System addressing the Power Quality Issue in Grid Connected Wind Energy Conversion System 9/15/2017 1

Grid Stability Analysis for High Penetration Solar Photovoltaics

Simulation Modeling and Control of Hybrid Ac/Dc Microgrid

EE 742 Chap. 7: Wind Power Generation. Y. Baghzouz Fall 2011

CHAPTER 5 FAULT AND HARMONIC ANALYSIS USING PV ARRAY BASED STATCOM

Integration of Large Wind Farms into Electric Grids

Wind Power Plants with VSC Based STATCOM in PSCAD/EMTDC Environment

Comparative Analysis of Integrating WECS with PMSG and DFIG Models connected to Power Grid Pertaining to Different Faults

Fuzzy based STATCOM Controller for Grid connected wind Farms with Fixed Speed Induction Generators

Effect of crowbar resistance on fault ride through capability of doubly fed induction generator

Research on Transient Stability of Large Scale Onshore Wind Power Transmission via LCC HVDC

ENHANCEMENT OF ROTOR ANGLE STABILITY OF POWER SYSTEM BY CONTROLLING RSC OF DFIG

EE 742 Chap. 7: Wind Power Generation. Y. Baghzouz

The Effect Of Distributed Generation On Voltage Profile and Electrical Power Losses Muhammad Waqas 1, Zmarrak Wali Khan 2

Wind Farm Evaluation and Control

CONTROL AND PERFORMANCE OF A DOUBLY-FED INDUCTION MACHINE FOR WIND TURBINE SYSTEMS

APPLICATION OF STATCOM FOR STABILITY ENHANCEMENT OF FSIG BASED GRID CONNECTED WIND FARM

Control Strategies for Supply Reliability of Microgrid

POWER QUALITY IMPROVEMENT BASED UPQC FOR WIND POWER GENERATION

COMPARISON OF DIFFERENT METHODS FOR EXCITATION OF SYNCHRONOUS MACHINES

Faults Mitigation Control Design for Grid Integration of Offshore Wind Farms and Oil & Gas Installations Using VSC HVDC

The hierarchical three layer protection of photovoltaic generators in microgrid with co-ordinated droop control for hybrid energy storage system

ASSESSING BEHAVOIR OF THE OUTER CROWBAR PROTECTION WITH THE DFIG DURING GRID FAULT

Analysis of Low Voltage Ride through Capability of FSIG Based Wind Farm Using STATCOM

Enhancement of Transient Stability Using Fault Current Limiter and Thyristor Controlled Braking Resistor

Modelling and Simulation of DFIG with Fault Rid Through Protection

Voltage Control Strategies for Distributed Generation

Impact of Islanding and Resynchroniza?on on Distribu?on Systems

CHAPTER 3 TRANSIENT STABILITY ENHANCEMENT IN A REAL TIME SYSTEM USING STATCOM

IMPROVEMENT IN DOUBLY FED INDUCTON GENERATOR UNDER FAULT USING INDUCTOR

Effect of prime mover speed on power factor of Grid Connected low capacity Induction Generator (GCIG)

Dynamic Study of Bonaire Island Power System: Model Validation and Project Experience

COMPARISON BETWEEN ISOLATED AND GRID CONNECTED DFIG WIND TURBINE

Electrical grid stability with high wind energy penetration

Modeling of Active Crowbar Protection Scheme for Various Types of Fault in Wind Energy Conversion System using DFIG

Workshop on Grid Integration of Variable Renewable Energy: Part 1

IEEE Transactions on Applied Superconductivity, 2012, v. 22 n. 3, p :1-5

Flywheels and Power System Stability

Use of STATCOM for Improving Dynamic Performance of Wind Farms Connected in Power Grid

Voltage Sag Mitigation in IEEE 6 Bus System by using STATCOM and UPFC

Laboratory Tests, Modeling and the Study of a Small Doubly-Fed Induction Generator (DFIG) in Autonomous and Grid-Connected Scenarios

Coordinated Control of DFIG under Grid Fault Condition in Wind Energy Conversion System

Transient Stability Improvement of Squirrel Cage Induction Wind Turbine Generator using Plugging Mode

Grid Code Testing of Wind Turbines by VSC-based Test Equipment

DISTRIBUTED GENERATION FROM SMALL HYDRO PLANTS. A CASE STUDY OF THE IMPACTS ON THE POWER DISTRIBUTION NETWORK.

Power Flow Simulation of a 6-Bus Wind Connected System and Voltage Stability Analysis by Using STATCOM

Combined Input Voltage and Slip Power Control of low power Wind-Driven WoundRotor Induction Generators

Possibilities of Distributed Generation Simulations Using by MATLAB

Power System Stability Analysis on System Connected to Wind Power Generation with Solid State Fault Current Limiter

ELECTRICAL POWER SYSTEMS 2016 PROJECTS

A STUDY ON ENERGY MANAGEMENT SYSTEM FOR STABLE OPERATION OF ISOLATED MICROGRID

Abstract. Benefits and challenges of a grid coupled wound rotor synchronous generator in a wind turbine application

A Variable Speed Wind Generation System Based on Doubly Fed Induction Generator

Performance Analysis of SCIG Coupled With Wind Turbine with and Without Fault Using RLC Load

Study of DFIG based Wind Turbine for Reactive Power Generation Capability

Critical Clearing Time and Voltage Stability of DG Integration in Lebanon: A Simulation Using MATLAB/SIMULINK

International Journal of Advanced Research in Electrical, Electronics and Instrumentation Engineering. (An ISO 3297: 2007 Certified Organization)

Studies regarding the modeling of a wind turbine with energy storage

Simulation and Analysis of a DFIG Wind Energy Conversion System with Genetic Fuzzy Controller

STUDY ON MAXIMUM POWER EXTRACTION CONTROL FOR PMSG BASED WIND ENERGY CONVERSION SYSTEM

DC Microgrid Management Using Power Electronics Converters

(by authors Jouko Niiranen, Slavomir Seman, Jari-Pekka Matsinen, Reijo Virtanen, and Antti Vilhunen)

Pumped storage for balancing wind power fluctuations in an isolated grid

Full-Scale Medium-Voltage Converters for Wind Power Generators up to 7 MVA

Primary frequency control by wind turbines

Dynamics of a hydro-wind hybrid isolated power system

Using energy storage for modeling a stand-alone wind turbine system

Design and Control of Lab-Scale Variable Speed Wind Turbine Simulator using DFIG. Seung-Ho Song, Ji-Hoon Im, Hyeong-Jin Choi, Tae-Hyeong Kim

Performance Analysis of Transient Stability on a Power System Network

APPLICATION OF VARIABLE FREQUENCY TRANSFORMER (VFT) FOR INTEGRATION OF WIND ENERGY SYSTEM

Squirrel cage induction generator based wind farm connected with a single power converter to a HVDC grid. Lluís Trilla PhD student

Performance of Low Power Wind-Driven Wound Rotor Induction Generators using Matlab

STABILIZATION OF ISLANDING PEA MICRO GRID BY PEVS CHARGING CONTROL

Reactive power support of smart distribution grids using optimal management of charging parking of PHEV

Performance Analysis of 3-Ø Self-Excited Induction Generator with Rectifier Load

Fault Rid Through Protection of DFIG Based Wind Generation System

Transient Stability Analysis of Power System with Wind Generators

A Case Study on Aggregate Load Modeling in Transient Stability Studies

Smart Integrated Adaptive Centralized Controller for Islanded Microgrids under Minimized Load Shedding

EFFECT OF WIND TURBINE GENERATORS ON THE SMALL SIGNAL STABILITY OF POWER SYSTEMS. Kamel A. Shoush, Member, IEEE

Islanding of 24-bus IEEE Reliability Test System

A.Arun 1, M.Porkodi 2 1 PG student, 2 Associate Professor. Department of Electrical Engineering, Sona College of Technology, Salem, India

ENHANCEMENT OF TRANSIENT STABILITY OF SMART GRID

Dynamic Performance Of DFIG Based WECS Under Different Voltage Sag

Grid Stability Analysis for High Penetration Solar Photovoltaics

IJSER. 1. Introduction. 2. Power flow of Doubly fed Induction Generator (DFIG) K. Srinivasa Rao 1 G. Kamalaker 2

Islanding of 24-bus IEEE Reliability Test System

PERFORMANCE ANALYSIS OF SQUIRREL CAGE INDUCTION GENERATOR USING STATCOM

Sliding Mode Control of a Variable Speed Wind Energy Conversion System based on DFIG

ANALYSIS OF WIND AND PV SYSTEMS 4.1 Wind Energy Conversion Systems (WECS)

CIS-IEEE 2017 Conference Renewable Energy Session Renewable Energy s Impact of Power Systems

Frequency Control of Isolated Network with Wind and Diesel Generators by Using Frequency Regulator

Impact of Reactive Power in Power Evacuation from Wind Turbines

THE IMPORTANCE OF INTEGRATING SYNCHRONOUS COMPENSATOR STATCOM IN WIND POWER PLANT CONNECTED INTO THE MEDIUM VOLTAGE GRID

DISTRIBUTED generation (DG) units, distributed storage

EPE97 OPTIMIZED DESIGN OF VARIABLE-SPEED DRIVES BASED ON NUMERICAL SIMULATION

Combination control for photovoltaic-battery-diesel hybrid micro grid system

J.-J.Simond*, A.Sapin**, B.Kawkabani*, D.Schafer***, M.Tu Xuan*, B.Willy***

Transcription:

FAULT ANALYSIS OF AN ISLANDED MICRO-GRID WITH DOUBLY FED INDUCTION GENERATOR BASED WIND TURBINE Yunqi WANG, B.T. PHUNG, Jayashri RAVISHANKAR School of Electrical Engineering and Telecommunications The University of New South Wales, Sydney, Australia ABSTRACT The increasing penetration of distributed generations (DGs) in the electrical system is causing severe transient stability problems since most of DGs are characterized by low inertias and poor inherent damping. In this paper, an islanded micro-grid with both synchronous machine and DGs is built to compare the transient stability of the system when a three-phase to ground fault occurs. The simulation result shows that the installation of DG improves the dynamic performance of the micro-grid, and when the DG source is the unit with the energy storage, this improvement is much more significant as this device can absorb power rush caused by the fault and it will supply a reactive compensation to recover the voltage after the fault. But this enhancement is reduced if the DG penetration level is too low or too high. The micro-grid with both storage unit and DFIG based wind turbine shows the best transient performance since both these DGs can reduce the negative effects from the fault. Key words Micro-grid, Fault, Wind Turbine, Battery Storage, DFIG INTRODUCTION The micro-grid technology is efficient in the sustainable development of the power industry, flexible and efficient in the integrated use of distributed and renewable power generation technology. And its power supply system combines distributed generations (DGs) with integrated system, which can reduce initial outlay, investment risks and energy consumption. Energy efficiency, power system reliability, power system flexibility and energy quality can also be improved with this system. And it will be an important development direction of the electrical industry in the future [1-4]. The drawbacks with DGs is that they are characterized by low inertias, high reactance, short time constant and poor inherent damping [5], which means, the dynamic performance of the whole system may be affected since DGs are unable to regulate system stability. This issue gets aggravated when networks begin to incorporate large numbers of DGs, as the overall dynamics of power system gets significantly impacted [6]. Various researches in the past studied the transient stability of the micro-grid with distributed generations. Reference [7] proves that the usage of inverter-based DG using droop control strategy improves the transient stability of the distribution system for a three-phase-fault. Reference [8] also shows that the micro-grid with a mix of synchronous and inverter based DG has a better transient stability performance. These previous works have made the following comparisons. Comparing fault performance of micro-grid in gridconnected / islanding mode. Comparing fault performance of micro-grid with different wind turbine conditions, including different control, crowbar protection or wind turbine type. A performance comparison of the wind turbines with other DG types is not investigated. Comparing fault performance of system with / without DGs. The nature of these sources being DC, they are equivalent to an energy source with storage units or even a pure storage system. The storage units are known to support the transient performance of micro-grids during faults, by exchanging the excess energy available in the system. However, with AC sources like wind turbines employing doubly-fed induction generators (DFIGs), for example, the transient performance of the micro-grid significantly deteriorate, as it does not have any energy storage parts and the constantly change in the rotor speed of the wind turbine also makes an impact on the micro-grid stability. The main aim of this paper is to compare the fault transients for micro-grids with synchronous machine, DFIG wind turbine and storage device. The simulation is carried out under four different scenarios: (i) the microgrid with only one synchronous generator, (ii) the microgrid with a synchronous generator (SG) and a DFIG wind turbine, (iii) the micro-grid including a synchronous generator and a storage unit, and (iv) the micro-grid including a synchronous generator, a DFIG wind turbine and a storage unit. A three-phase-fault is applied to the system at the same bus and the fault clearing time is the same for all simulation scenarios. The characteristics of the SG and the point of common coupling are analyzed to show the difference in transient performance. FAULT PROTECTION OF DFIG WIND TURBINE For DFIG based wind turbine, crowbar is the most commonly used protection method against the large short circuit current caused by the suddenly drop of grid voltage [9]. CIRED 2015 1/5

Fig.1 The topology of a typical crowbar protection Figure 1 shows the topology of a typical crowbar protection. The crowbar will be quickly connected into the rotor side when the fault at grid side is detected. It short circuits the rotor to protect the converter and the system goes to an asynchronous machine operation mode [10]. However, if the fault duration is large and the crowbar is connected for a long time, the problem of reactive power absorption arises which will delay the reconstruction of grid voltage [11]. SYSTEM AND MICRO-GRID STRUCTURE The micro-grid model used in the simulation is shown in Figure 2. The micro-grid works in islanding mode and it connects to grid side via a 15MVA, 1.38/13.8KV transformer and a 2 km transmission line. The system consists of a synchronous machine and a DG which can be either wind turbine or a battery storage device. Two 4MW, 0.9pf lagging load are also connected. Both DGs are controlled by droop control strategy. The three-phase to ground fault is simulated at grid side at t=5s and it is cleared at t=5.2s. The characteristics of SG and DG, and the voltage at the point of common coupling (PCC) are obtained to show the transients with different DG source and penetration. IMPACT OF DIFFERENT DG SOURCES In this section, the system response for a sudden three-phase to ground fault at bus 1 is discussed in four different micro-grid configurations, which include a pure synchronous machine power injection, a mix of synchronous and DFIG-based wind turbine power injection, a mix of synchronous and storage unit power injection and a mix of synchronous, DFIG-based wind turbine and storage unit. Micro-grid with only synchronous generator In this configuration, the distributed generators are not used and a synchronous generator is the only source to supply the total load demand. The inertia constant (H) is 3MJ/MVA and Figure 3 shows the characteristics of SG and the PCC voltage and frequency when the fault is cleared in 10 cycles. From Figure 3 it is observed that when the fault is cleared 0.2s after occurrence, the micro-grid with only SG unit can still maintain stability. But the SG takes a very long time to obtain to its new balance. It is obvious that the SG rotor speed and PCC electrical frequency increases rapidly after the fault, and at about t=10s, the rotor speed gets to the peak value (1.03pu) and it then goes down. However, it does not reach steady state even at t=60s, at which point the simulation is stopped. A similar change can also be found in Figure 3(b) and the peak value of electrical frequency is about 51.6 HZ. SG Speed in pu Fig.3 (a) SG rotor speed in pu PCC Electrical Frequency in HZ Fig.3 (b) PCC electrical frequency in HZ Fig.2 The micro-grid model CIRED 2015 2/5

SG Rotor Speed in pu Fig.3 (c) PCC voltage in pu The PCC voltage shown in figure 3(c) drops during the three-phase fault and when the fault cleared at t=5.2s, the PCC voltage begins to recover but this recovery time is long (more than 60s) because the SG reactive power increases slowly after the fault. And the voltage dip is the largest in this case because there is no component that can compensate for the voltage dip during the fault. Micro-grid including a synchronous and a DFIGbased wind turbine The micro-grid in this configuration consists of a 4MW synchronous generator together with a 4MW DFIG-based wind turbine, the inertia constant of SG being maintained at 3 MJ/MVA. The three-phase fault is simulated at same bus and the fault clearing time is still in 10 cycles after the fault. As shown in Figure 4, following the fault at t=5s, the voltage sag appeared in the micro-grid and crowbar protection of wind turbine short circuited the rotor side converter (RSC) after a 3ms short delay and the wind turbine goes to an asynchronous machine operation mode. The reactive power output of wind turbine is below 0, which means the wind turbine absorbs power from the grid. After 63ms the crowbar is disconnected and the RSC is re-synchronized and the wind turbine starts to supply active and reactive power; the crowbar operation is minimized to start injecting reactive power to the grid although the fault is still not cleared. But because the PCC voltage is low at this time, the active power output doesn t increase until the fault is cleared. The active power output increases at t=5.2s and the wind turbine works as DFIG again. The micro-grid shows a better dynamic response when the DFIG-based wind turbine is installed. The PCC voltage has a smaller drop because wind turbine absorbs power from the grid to compensate the voltage dip when it operates in asynchronous generator mode. The wind turbine power drop is the main reason for the frequency overshooting during the fault, but the SG rotor speed and system frequency increase are less after the fault since the SG active power variation is smaller. And it still takes about 40sec for the voltage to recover (stable at t=45s) because the wind turbine with crowbar protection can t produce enough power to support the voltage recovery after the fault. Fig.4 (a) SG rotor speed in pu DFIG Active DFIG Reactive Fig.4 (b) PCC electrical frequency in HZ Fig.4 (c) PCC voltage in pu 4.090 3.244 2.398 1.552 0.706-0.140 4.460 2.960 1.460-0.040-1.540-3.040 Fig.4 (d) Wind turbine power output during the fault Micro-grid including a synchronous and a storage unit The storage unit is used as the DG source in this configuration. It can be considered equivalent to either a renewable energy source with a storage unit or a pure storage device. The dynamic performance of the microgrid is highly enhanced because the storage unit can absorb power rush caused by the fault without any impact on the system frequency, as shown in Figure 5. CIRED 2015 3/5

SG Rotor Speed in pu Micro-grid including a synchronous, a DFIG based wind turbine and a storage unit Both the DFIG based wind turbine and storage unit are connected at PCC bus in this configuration. The load demand is shared by SG and wind turbine initially. The system transient performance for the fault is shown in Figure 6. Fig.5 (a) SG rotor speed in pu SG Speed in pu Fig.6 (a) SG rotor speed in pu Fig.5 (b) PCC electrical frequency in HZ Fig.6 (b) PCC electrical frequency in HZ Battery Active Battery Reactive Fig.5 (c) PCC voltage in pu 4.170 3.398 2.626 1.854 1.082 0.310 3.100 2.454 1.808 1.162 0.516-0.130 Fig.5 (d) Storage unit power output during the fault The PCC voltage has a smaller drop since the battery delivers reactive power to PCC bus during the fault. The active power output of battery increases rapidly after the fault, and hence the SG rotor speed variations and PCC frequency oscillations remain smaller. The micro-grid recovers at t=15s because the storage unit delivers the reactive power after the fault to help the fast recovery of the PCC voltage. DFIG Active DFIG Reactive Fig.6 (c) PCC voltage in pu 4.080 3.254 2.428 1.602 0.776-0.050 4.690 3.002 1.354-0.314-1.982-3.650 Fig.6 (d) Wind turbine power output during the fault CIRED 2015 4/5

Battery Active Battery Reactive 0.080-0.242-0.564-0.886-1.208-1.530 2.980 2.356 1.732 1.108 0.484-0.140 Fig.6 (e) Storage unit power output during the fault The battery begins to deliver reactive power and absorb active power at t=5s to balance the system during the disturbance. The DFIG wind turbine also absorbs reactive power from the grid side when crowbar protection is operated, so the PCC voltage reduction is the smallest and SG rotor speed also has the least increase with the smallest power variation. The electrical frequency in this case shows the least oscillation after the fault. But the initial overshoot following the fault is higher than in scenario 3 as the wind turbine rotor speed change also affects the system frequency. The PCC voltage is stable at t=10s, which is the shortest among the four scenarios. CONCLUSION This paper investigates the dynamic response of an islanded micro-grid when a sudden three-phase fault is applied. The simulation results show that the integration of DG in the micro-grid can help improve the transient performance of both the synchronous generator (SG) and micro-grid. With the wind turbine connected, the voltage dip is smaller, and the transients on the SG rotor speed and electrical frequency are reduced. The recovery time needed for the system to go back to the initial state is also decreased by connecting a DG. And this improvement is much more significant when the storage unit is used as the DG source. The best dynamic performance is found in the micro-grid with both DFIG-based wind turbine and battery storage connected. REFERENCES [1] Y. Zoka, H. Sasaki, N. Yorino, K. Kawahara, and C. Liu, "An interaction problem of distributed generators installed in a MicroGrid," in Electric Utility Deregulation, Restructuring and Power Technologies, 2004.(DRPT 2004). Proceedings of the 2004 IEEE International Conference on, 2004, pp. 795-799. [2] R. H. Lasseter and P. Paigi, "Microgrid: a conceptual solution," in Power Electronics Specialists Conference, 2004. PESC 04. 2004 IEEE 35th Annual, 2004, pp. 4285-4290. [3] F. Wang, Y. Qi, and Z. Fu, "Reliability Evaluation of Distribution System with Multiple Micro-Sources," Przegląd Elektrotechniczny, vol. 89, 2013. [4] M. A. Kashem and G. Ledwich, "Multiple distributed generators for distribution feeder voltage support," Energy Conversion, IEEE Transactions on, vol. 20, pp. 676-684, 2005. [5] F. Edwards, G. Dudgeon, J. McDonald, and W. Leithead, "Dynamics of distribution networks with distributed generation," in Power Engineering Society Summer Meeting, 2000. IEEE, 2000, pp. 1032-1037. [6] A. M. Azmy and I. Erlich, "Impact of distributed generation on the stability of electrical power system," in Power Engineering Society General Meeting, 2005. IEEE, 2005, pp. 1056-1063. [7] X. Chen, W. Pei, and X. Tang, "Transient stability analyses of micro-grids with multiple distributed generations," in Power System Technology (POWERCON), 2010 International Conference on, 2010, pp. 1-8. [8] A. H. K. Alaboudy and H. Zeineldin, "Critical clearing time for isolating microgrids with inverter and synchronous based Distributed Generation," in Power and Energy Society General Meeting, 2010 IEEE, 2010, pp. 1-6. [9] S. Ayasun, Y. Liang, and C. O. Nwankpa, "A sensitivity approach for computation of the probability density function of critical clearing time and probability of stability in power system transient stability analysis," Applied mathematics and computation, vol. 176, pp. 563-576, 2006. [10] H. Zhou, G. Yang, and D. Li, "Short circuit current analysis of DFIG wind turbines with crowbar protection," in Electrical Machines and Systems, 2009. ICEMS 2009. International Conference on, 2009, pp. 1-6. [11] I. Erlich, H. Wrede, and C. Feltes, "Dynamic behavior of DFIG-based wind turbines during grid faults," in Power Conversion Conference-Nagoya, 2007. PCC'07, 2007, pp. 1195-1200. CIRED 2015 5/5