VOLTAGE BALANCING IN SOLAR BASED DC MICRO-GRID SYSTEM

Similar documents
Simulation Analysis of Closed Loop Dual Inductor Current-Fed Push-Pull Converter by using Soft Switching

Power Electronics Projects

INTERNATIONAL JOURNAL OF ELECTRICAL ENGINEERING & TECHNOLOGY (IJEET)

BIDIRECTIONAL DC-DC CONVERTER FOR INTEGRATION OF BATTERY ENERGY STORAGE SYSTEM WITH DC GRID

Design of Four Input Buck-Boost DC-DC Converter for Renewable Energy Application

Performance Analysis of Bidirectional DC-DC Converter for Electric Vehicle Application

Inverter with MPPT and Suppressed Leakage Current

Implementation Soft Switching Bidirectional DC- DC Converter For Stand Alone Photovoltaic Power Generation System

Bidirectional Intelligent Semiconductor Transformer

Co-Ordination Control and Analysis of Wind/Fuel Cell based Hybrid Micro-Grid using MATLAB/Simulink in Grid Connected Mode

Design of Active and Reactive Power Control of Grid Tied Photovoltaics

Design of Three Input Buck-Boost DC-DC Converter with Constant input voltage and Variable duty ratio using MATLAB/Simulink

SPIRO SOLUTIONS PVT LTD POWER ELECTRONICS 1. RENEWABLE ENERGY PROJECT TITLES I. SOLAR ENERGY

Analysis and Design of Improved Isolated Bidirectional Fullbridge DC-DC Converter for Hybrid Electric Vehicle

IJSRD - International Journal for Scientific Research & Development Vol. 4, Issue 02, 2016 ISSN (online):

Dynamic Modelling of Hybrid System for Efficient Power Transfer under Different Condition

Control System and Performance of DC Micro grid under Various Loads

POWER ELECTRONICS & DRIVES

Figure 1 I-V characteristics of PV cells. Meenakshi Dixit, Dr. A. A. Shinde IJSRE Volume 3 Issue 12 December 2015 Page 4687

BIDIRECTIONAL FULL-BRIDGE DC-DC CONVERTER WITH FLYBACK SNUBBER FOR PHOTOVOLTAIC APPLICATIONS

Increasing the Battery Life of the PMSG Wind Turbine by Improving Performance of the Hybrid Energy Storage System

Integration of Ultra-Capacitor Using Bidirectional Converter with RES Applications

A Transient Free Novel Control Technique for Reactive Power Compensation using Thyristor Switched Capacitor

The hierarchical three layer protection of photovoltaic generators in microgrid with co-ordinated droop control for hybrid energy storage system

Research Paper MULTIPLE INPUT BIDIRECTIONAL DC-DC CONVERTER Gomathi.S 1, Ragavendiran T.A. S 2

Development of Novel Connection Control Method for Small Scale Solar - Wind Hybrid Power Plant

A Bidirectional Universal Dc/Dc Converter Topology for Electric Vehicle Applicationsand Photovoltaic Applications

1. RENEWABLE ENERGY I.SOLAR ENERGY PROJECT TITLES WE CAN ALSO IMPLEMENT YOUR OWN CONCEPT/IDEA

Multi-Port DC-DC Converter for Grid Integration of Photo Voltaic Systems through Storage Systems with High Step-Up Ratio

A Novel DC-DC Converter Based Integration of Renewable Energy Sources for Residential Micro Grid Applications

Hybrid Three-Port DC DC Converter for PV-FC Systems

A PARALLEL SNUBBER CAPACITOR BASED HIGH STEP UP ISOLATED BIDIRECTIONAL FULL BRIDGE DC TO DC CONVERTER

Simulation Modeling and Control of Hybrid Ac/Dc Microgrid

NOVEL MODULAR MULTIPLE-INPUT BIDIRECTIONAL DC DC POWER CONVERTER (MIPC) FOR HEV/FCV APPLICATION

The Master of IEEE Projects. LeMenizInfotech. 36, 100 Feet Road, Natesan Nagar, Near Indira Gandhi Statue, Pondicherry

Modeling and Simulation of Multi-input Bi-directional Boost Converter for Renewable Energy Applications using MatLab/Simulink

FOUR SWITCH THREE PHASE BRUSHLESS DC MOTOR DRIVE FOR HYBRID VEHICLES

Power Electronics & Drives [Simulink, Hardware-Open & Closed Loop]

INVESTIGATION AND PERFORMANCE ANALYSIS OF MULTI INPUT CONVERTER FOR THREE PHASE NON CONVENTIONAL ENERGY SOURCES FOR A THREE PHASE INDUCTION MOTOR

Reactive Power Sharing Droop Control Strategy for DG Units in an Islanded Microgrid

K. Surendhirababu *, D. Karthikeyan *, K. Vijayakumar *, K. Selvakumar * and R. Palanisamy *

DESIGN AND ANALYSIS OF CONVERTER FED BRUSHLESS DC (BLDC) MOTOR

Research on PV and battery control system with energy management technology in stand-alone DC micro grid

International Journal of Advanced Research in Electrical, Electronics and Instrumentation Engineering. (An ISO 3297: 2007 Certified Organization)

Energy Management and Control for Grid Connected Hybrid Energy Storage System under Different Operating Modes

INTERNATIONAL JOURNAL OF ENGINEERING SCIENCES & RESEARCH TECHNOLOGY

Design and Implementation of Non-Isolated Three- Port DC/DC Converter for Stand-Alone Renewable Power System Applications

Power Grid Applications of Renewable Energy Based Bidirectional DC DC Converter with ZVS in DCM Operation

Design and Development of Bidirectional DC-DC Converter using coupled inductor with a battery SOC indication

Abstract- In order to increase energy independency and decrease harmful vehicle emissions, plug-in hybrid electric vehicles

Dual power flow Interface for EV, HEV, and PHEV Applications

Analysis of Grid Connected Solar Farm in ETAP Software

Fuzzy logic controlled Bi-directional DC-DC Converter for Electric Vehicle Applications

Simulation of Fully-Directional Universal DC- DC Converter for Electric Vehicle Applications

Advance Electronic Load Controller for Micro Hydro Power Plant

Design and Simulation of Grid Connected PV System

Modelling of a Standalone Photovoltaic System with Charge Controller for Battery Energy Storage System

Modelling and Analysis of Bidirectional DC-DC Converter. Abstract

ANFIS CONTROL OF ENERGY CONTROL CENTER FOR DISTRIBUTED WIND AND SOLAR GENERATORS USING MULTI-AGENT SYSTEM

Development and Analysis of Bidirectional Converter for Electric Vehicle Application

International Journal of Advance Research in Engineering, Science & Technology

Modelling and Control of Ultracapacitor based Bidirectional DC-DC converter systems PhD Scholar : Saichand K

BI-DIRECTIONAL DC-DC CONVERTER FOR ENERGY STORAGE IN SOLAR PV SYSTEM

Control Scheme for Grid Connected WECS Using SEIG

POWER ELECTRONICS TITLES LeMeniz Infotech

A Novel GUI Modeled Fuzzy Logic Controller for a Solar Powered Energy Utilization Scheme

FAULT ANALYSIS FOR VOLTAGE SOURCE INVERTER DRIVEN INDUCTION MOTOR DRIVE

Design and Control of Hybrid Power System for Stand-Alone Applications

A.Arun 1, M.Porkodi 2 1 PG student, 2 Associate Professor. Department of Electrical Engineering, Sona College of Technology, Salem, India

Power Management with Solar PV in Grid-connected and Stand-alone Modes

EXTENDED PHASE SHIFT CONTROL OF ISOLATED BIDIRECTIONAL DC-DC CONVERTER FOR RENEWABLE ENERGY SOURCES CONNECTED TO MICRO GRID

Power System Stability Analysis on System Connected to Wind Power Generation with Solid State Fault Current Limiter

Fuzzy Logic Control Based MIMO DC-DC Boost Converter for Electric Vehicle Application Ans Jose 1 Absal Nabi 2 Jubin Eldho Paul 3

Isolated Bidirectional DC DC Converter for SuperCapacitor Applications

A Study of Suitable Bi-Directional DC-DC Converter Topology Essential For Battery Charge Regulation In Photovoltaic Applications

DC Microgrid Management Using Power Electronics Converters

Sensor less Control of BLDC Motor using Fuzzy logic controller for Solar power Generation

Power Flow Management and Control of Hybrid Wind / PV/ Fuel Cell and Battery Power System using Intelligent Control

STUDY ON MAXIMUM POWER EXTRACTION CONTROL FOR PMSG BASED WIND ENERGY CONVERSION SYSTEM

Power Quality and Power Interruption Enhancement by Universal Power Quality Conditioning System with Storage Device

International Journal Of Global Innovations -Vol.2, Issue.I Paper Id: SP-V2-I1-048 ISSN Online:

CHAPTER 1 INTRODUCTION

Wind-Turbine Asynchronous Generator Synchronous Condenser with Excitation in Isolated Network

Behaviour of battery energy storage system with PV

Fuzzy based STATCOM Controller for Grid connected wind Farms with Fixed Speed Induction Generators

Technology from the New Product SANUPS K for a Smart Grid Society

Design of Intelligent Charger for Electric Vehicles

INTELLIGENT DC MICROGRID WITH SMART GRID COMMUNICATIONS: CONTROL STRATEGY CONSIDERATION AND DESIGN

Review & Study of Bidirectional of DC-DC Converter Topologies for Electric Vehicle Application

A Bidirectional DC-DC Battery Interface for EV Charger with G2V and V2X Capability

A Novel Hybrid PV/Wind/Battery based Generation System for Grid Integration

IMPROVEMENT OF POWER QUALITY OF AC MICROGRID WITH ENERGY SYSTEM USING BY ELECTRIC DOUBLE LAYER CAPACITOR

ENHANCEMENT OF ROTOR ANGLE STABILITY OF POWER SYSTEM BY CONTROLLING RSC OF DFIG

Power Balancing Under Transient and Steady State with SMES and PHEV Control

Implementation of Bidirectional DC/AC and DC/DC Converters for Automotive Applications

NOVEL VOLTAGE STABILITY ANALYSIS OF A GRID CONNECTED PHOTOVOLTIC SYSTEM

Enhancement of Voltage Stability by using Fuel Cell as Shunt Compensator

ENERGY MANAGEMENT FOR HYBRID PV SYSTEM

Modeling Comparision Of Solar Pv/ Fuelcell/Ultra Capacitor Hyrbrid System For Standalone And Grid Connected Application

INTERNATIONAL JOURNAL OF PURE AND APPLIED RESEARCH IN ENGINEERING AND TECHNOLOGY

Transcription:

VOLTAGE BALANCING IN SOLAR BASED DC MICRO-GRID SYSTEM Darshana Baghel 1, Mr. Ram Ratan Tiwari 2 1PG Scholar, 2 Lecturer,Electrical Department, LDRP-ITR, Gandhinagar, Gujarat, India ---------------------------------------------------------------------***--------------------------------------------------------------------- Abstract -A DC micro grid system is a novel power system to demand sites. To reduce energy dissipation through the that introduce a huge amount of solar power using transmission, the power is sent near the demand site after being raised the electric voltage to 66 kv or higher. A distributed photovoltaic generation units. The redox flow micro-dc grid generally operates on one voltage level in battery is an important component which help in rapid two-wire distribution system, and it is impossible to charge-discharge even under the fluctuating condition of supply some types of loads at half voltage such as dc/ac power generation and consumption, supply-demand inverters needing a neutral line, converters with input adjustment takes place in the micro grid system. In microgrid voltage balancing like half- bridge converter and three- power transmit with the help of two wire is generally level half-bridge converter, and so on. Shoot-through problem which existed in bridge type converters can be not suitable for the requirements of the input voltage levels solved by dual buck half bridge voltage balancer. For of different power converters and loads. In order, to fulfil the meeting the characteristic of the proposed voltage demand, a micro-dc grid introduced half-bridge voltage balancer, a control strategy of respectively driving the two balancer, which convert a two-wire system into a three-wire system in which neutral line exist. Here control strategy and dual buck half-bridge voltage balancer itself are proposed to avoid the shoot-through problem which existed in bridge legs of the proposed voltage balancer to work for a high efficiency is also presented. When a dc-micro grid is used in residential and work places, neutral wire is used to security. bridge type converters. shoot-through problem can be solved with the help of Complementary driving technology. Key Words:DC micro grid, Voltage Balancer and RF battery 1. INTRODUCTION The increasing demand for development of power from renewable energy (Solar energy) has led to creation of Micro-dc grid. A micro-grid can be defined as a group of local electrical sources and loads that are operated in correction to and in synchronism with conventional grid but can also be operated in disconnected and autonomous system.a dc-micro grid is depending upon on some interfacing converter, such as grid-connected inverter, bidirectional converter and dc converter, and voltagebalancer and so on. PV modules generate DC electric power. The main components of a micro grid are: (i) distributed generation sources such as photovoltaic panels, small wind turbines, fuel cells, diesel and gas micro turbines, etc., but here we only considered PV panels, (ii) distributed energy storage devices such as batteries, super capacitors, etc., and (iii) critical and non-critical loads.[3] Here silicon photovoltaic (Si-PV)units, copper indium gallium selenide photovoltaic (CIGS-PV) units, concentrator photovoltaic (CPV) units, and a redox flow battery are used to check the feasibility of the system. The power should be converted to AC that is synchronized with commercial grids to be transmitted and distributed 2. TOPOLOGY AND CHARACTERISTICS OF MICRO-DC GRID SYSTEM 2.1 Topology In DC, micro grid source, load, storage, AC grid are connected to DC bus via various converters such as grid side converter(gsc), storage side converter(ssc), load side converter(lsc), renewable side converter(rsc) and other required devices. In generator side power generated is in AC form which links with Grid Side Converter where AC power is converted into DC power. In GSC reverse power flow is also possible. Storage side converter has DC- DC converter which connect DC bus and storage elements such as super capacitor, battery, flywheel and EDLC, etc. Renewable side super capacitor, battery, flywheel and EDLC, etc. Renewable side converter has interface between dc bus and renewable sources such as PV cells, fuel cells, wind turbine, etc. Fig-1: Micro-DC Grid System 2017, IRJET Impact Factor value: 5.181 ISO 9001:2008 Certified Journal Page 964

2.2 Characteristics Characteristics of the micro-dc grid system is summarized in few sentences: 1) In DC, micro grid problems such as voltage, frequency and synchronization does not exit unlike AC micro grid. 2) In load side converters distributed schemes are contributed to supply a super high quality power. For example, if any problem like short circuit occurs on one side, then also other loads remain unaffected. 3) Here in micro-dc grid system electric powers like single phase, three phase AC, two wire DC and DC with neutral can be obtained. 4) Reduce energy loss and utility cost which results from AC/DC converters so it increases system s efficiency. 5) Such type of dc distribution system is suitable for generations such as photovoltaic and fuel cell, and energy storages such as secondary batteries and EDLCs whose output is dc. 6) This system proves itself protected type of system because in case of any accident power system, this system can be separated from the power system fastly. And during isolation, it maintains continuity of supply. 7) Electric power in micro-dc grid is shared by using additional electric power lines between load side converters when overload occurs. 8) In DC, micro grid three wire distribution system protect personnel from any type of shock. Fig.2: Dual bulk half-bridge voltage balancer. 3.2 Controlled strategy The switch S1 is controlled by the output signal (ue)of the voltage regulator but its negative value (-ue) controls the switch S2.The PI algorithm used for feedback of current controller. The signal ue is positive when R Load1 is larger than R Load2, and the left bridge leg is on, at that time right bridge leg will not work. So, due to complementary driving technique only one of the two bridge leg will operate during every switching period. 3. VOLTAGE BALANCER AND CONTROL STRATEGY 3.1 Voltage Balancer Voltage balancer consist of two bridge legs, namely left bridge leg and right bridge leg and a neutral line which usually connected to earth. In this dual buck half bridge voltage balancer, complementary driving technology is used between two MOSFET switches. Each bridge consists of MOSFET switches, diode, inductor and capacitor. In this control strategy, it is expected it drive the left bridge leg and the right bridge leg respectively based on the different power quantity of the unbalanced loads. Fig-3: Control Strategy Each bridge operates in continuous conduction mode (CCM) and discontinuous conduction mode (DCM). For simplifications, some assumptions are made such as: 1) During each switching process output voltages u out1 and u out2 do not change. 2) All diodes and power switches are the ideal devices do not consider voltage drops and losses. 3) All capacitors and inductors are ideal, and C1 = C2 = C, L2 = L2 = L. 2017, IRJET Impact Factor value: 5.181 ISO 9001:2008 Certified Journal Page 965

Continuous Conduction Mode (CCM) Operation There are two main modes of operations such as: 1) Mode-1: During the time [t1, t2] switch S1 is on at t=0 and current through inductor L1 increases linearly. This current flows through filter inductor, filter capacitor and load resistor. The voltage across the freewheeling diode D1 is the input voltage. L1 (di L1/ dt) = Uin Uout2 = Uout1.(i) 2) Mode-2: During the interval [t1, t2] switch S1 turned off at t = t1. From the interval t1 current il1 starts decreasing linearly. Discontinuous Conduction Mode (DCM) Operation In DCM, there are three modes of operations in which mode-1, 2 are same as that of continuous conduction mode and mode-3 is extra in discontinuous conduction mode. Mode-3: Loads RLoad1 and RLoad2 are supplied by the voltage sources Uout1 and uout2 during the interval [t2, t3]. Load discharge the energy which is stored in the capacitor. Here turned on time (t1-t0) is lesser than turned off (t3-t1) time. Uout1(t1 t0) = uout2(t2 t1) (iv) L1 di L1/dt = Uout2 (ii) When switch S1 is turned off, the freewheeling diode D1 conducts due to energy stored in the inductor, and the inductor current continuously flow through L, C, load and diode D1. This current flows and become zero until switch S1 again become on. In CCM the turn on time is equal to the turn off time i.e., (t1-t0) = (t2-t1). Uout1 (t1 t0) = Uout2 (t2 t1) (iii) Fig-5: Driving signal and inductor current waveform under DCM a 4. CONTROLLED STRATEGY AND ITS SIMULATION The analysis of the main current relationships and the loads transiently changing are carried out by using MATLAB. For the half bridge Inverter, single phase voltage 110V is considered and 220 V for a full bridge inverter. The DC bus voltage input voltage; u in is selected to be 360 V. The other parameters for simulation are such as: switching frequency of 25 khz,l1 =L2 = 230μH, and C1 = C2 = 470μF. In case of CCM [RLoad1 = 100Ω and RLoad2 = 10 Ω] and of DCM [RLoad1 = 40 Ω and RLoad2 = 30 Ω]. [2] Fig-4: Driving signal and current through inductor waveform under CCM 2017, IRJET Impact Factor value: 5.181 ISO 9001:2008 Certified Journal Page 966

The simulation results of the current relationships of the left bridge leg are given. Figure 6: Simulation result of control strategy o/p of Figure 9: Voltage across capacitor C1 switch 1(MOSFET) Figure 7: Output signal which is measure across the load i.e. Rload2 & Rload1 Figure 8: Current waveform of Inductor L1 i.e. I L1 and Figure 10: Voltage across capacitor C2 4. SUPPLY AND DEMAND CONTROL BY RF BATTERY Storage batteries and control units are the key components of DC micro grid. The DC micro grid needs storage element that ensures durability while demand is high and can quickly respond to any changes in the current. A RF battery has very excellent qualities which satisfies the conditions such as quick response, large capacity, precise and high durability. Redox deprived from two words Reduction and oxidation and in this battery reduction-oxidation reaction takes place in the electrolytic solution which circulates between cells and tanks. The active materials on Positive electrode is VO 2+ /VO 2+ and on negative electrode is V 3+ /V 2+. L2 i.e. I L2 2017, IRJET Impact Factor value: 5.181 ISO 9001:2008 Certified Journal Page 967

REFERENCES 1). Xianjin Zhang And Chunying Gong, Member, IEEE Dual-Buck Half-Bridge Voltage Balancer IEEE Transactions on Industrial Electronics, Vol. 60, No. 8, August 2013. 2). Dual-Buck Half-Bridge Voltage Balancer Telugu Siva Sai1 And P. Sai Sampath Kumar, International Journal of Innovative Research in Science & Engineering, ISSN (Online) 2347-3207. Fig-6: Diagram of redox Flow battery Among the secondary batteries such as Li ion battery, NaS battery are very efficient in DC micro grid system. Fluctuation on the output side is smoothened by RF Battery and this battery is also used for detection of state of charge (SOC) during the current flows in the cells. DC- DC converter connects the battery to the Dc bus to control the charge and discharge during demand and supply. Electric power flows from the generator to the DC bus, and flows out to loads. When the electric power flows from generator to the DC bus is larger than the power flows out to the load, the voltage of the bus increases and vice versa. Supply and demand balance of the system can be maintained because the bi-directional DC-DC converter control the voltage of the DC bus at constant by charging, when it is higher than a target, or dis-charging, when it is lower. The battery charges when its voltage at distant point is higher because power generation is greater than power consumption, while voltage is lower during discharge 2). H. Kakigano, Y. Miura, T. Ise, and R. Uchida, DC voltage control of the DC micro-grid for super high quality distribution, in Proc. IEEE PowerElectronics Specialists Conference, Korea, 2006, pp.518-525. 3). Naoki AyAi *, Toshiya HisAdA, Toshikazu shibata, Hidekazu MiyosHi, Takashi iwasaki and ken-ichi kitayama DC Micro Grid System. 4). S. V. V. S. K. Reddy1 and Y. Srinivavasa Rao2 ADVANCED FUZZY LOGIC CONTROL BASED DUAL- BUCKHALF-BRIDGE VOLTAGE BALANCER, Industrial Science, ISSN: 2347-5420, Volume-1 Issue-7 Oct-2014. 5). Sandeep Anand and B. G. Fernandes Optimum voltage level for DC micro grids Electrical Engineering Department Indian Institute of Technology Bombay, India, IEEE member. 6). DC MICROGRIDS A SOLAR BACK TO THE FUTURE Sol Haroon, Lead Systems Engineer, SOL@SUNIVA.COMDecember 2012. 5. CONCLUSIONS Micro-DC grid, its characteristics and advantages are reexplained here. In this paper, dual half buck voltage balancer which is used in micro-dc grid and its control strategy are explained. A neutral line is created which is connected earth to balance two output voltages and to protect personnel from any type of hazards. Voltage balancer has ability to overcome the shoot-through problem. Under fluctuating load, unbalanced loads and different input voltage it can balance its output voltage. Storage element like RF battery is explained which maintain supply and demand balance in the system. 2017, IRJET Impact Factor value: 5.181 ISO 9001:2008 Certified Journal Page 968