General technical data: CONTACTOR, AC-3, 11KW/400V, 1NO+1NC, AC110V 50HZ, 120V 60HZ 3-POLE, SZ S0 SCREW TERMINAL. product brand name

Similar documents
General technical data: CONTACTOR, AC-3, 5.5KW/400V, 1NC, AC110V 50HZ, 120V 60HZ 3-POLE, SZ S00 SCREW TERMINAL. product brand name

General technical data: CONTACTOR, AC-3, 4KW/400V, 2NO+2NC, DC 24V, 3-POLE, SZ S0 SCREW TERMINAL REMOVABLE AUX. SWITCH. product brand name

General technical data: CONTACTOR, AC-3, 18.5KW/400V, 1NO+1NC, DC 24V, 3-POLE, SZ S0 SCREW TERMINAL. product brand name

CONTACTOR, AC-3 15 KW/400 V, AC 110V 50HZ/120V 60HZ 3-POLE, SIZE S2, SCREW CONNECTION. General technical data: Main circuit: product brand name

CONTACTOR, AC-3 4 KW/400 V, 1 NC, DC 24 V, 3-POLE, SIZE S00, SCREW CONNECTION. General technical data: Main circuit: product brand name

General technical data. Ambient conditions

CONTACTOR, AC KW/400 V, DC 24 V, 3-POLE, SIZE S0, SCREW CONNECTION. General details: Main circuit: Product brand name. Size of the contactor

3RT2028-1BB40. at rectangular impulse at DC 10g / 5 ms, 7,5g / 10 ms at sine pulse at DC 15g / 5 ms, 10g / 10 ms

3RT14 Contactors with 3 Main Contacts

3RV2011-1AA10 CIRCUIT-BREAKER SCREW CONNECTION 1.6A

B Mini Contactor V Hz

Technical specifications

Application Mini Contactors for Motors and Resistive Loads

Mini contactors B6, BC6 with 3 pole

Protection Equipment

AF40... AF96 3-pole contactors Technical data

MS General Information Extended Product Type: MS

Page. Circuit-Breakers M4 2 for motor protection. Auxiliary contacts 3 Signalling switch Auxiliary releases

Thermal Overload Relays - WEG RW Series, 2 Pole

Industrial Contactors CTX 3 3P 185A - 800A

Approbationen IEC/EN ; UL 508; CSA-C22.2 No ; CE marking

BC Mini Contactor VDC

DEVICE STATE/BYPASSED FAILURE OVERLOAD

3RV1011-0DA15 CIRCUIT-BREAKER, SIZE S00,

Meta Solution. Contactors and Overload relays

SIRIUS 3RU2 Thermal Overload Relays

MS /27/2015. ABB contact for United States of America. General Information Extended Product Type: Categories

Circuit-Breakers M4 166 for motor protection. Auxiliary contacts 167 Signalling switch Auxiliary releases

DATASHEET - DILMC9-10(24VDC) Technical data General. Contactor, 3p+1N/O, 4kW/400V/AC3. Catalog No Eaton Catalog No. XTCEC009B10TD.

Siemens AG Switch Disconnectors SENTRON. Configuration. Edition 10/2015. Manual. siemens.com/lowvoltage

AE 9... AE 40 Contactors NE... Contactor Relays

CTX 3 Control relays Cat. N (s) : /06/09..14/16/19..24/26/29

Motors Automation Energy Transmission & Distribution Coatings. Automation Contactors - CWM Line

Siemens AG Price groups PG 14O, 41B, 41E, 41F, 41G, 41H, 41J, 42F, 42J

ASL09..S 3-pole Contactors - Spring Terminals

3VU13, 3VU16 Circuit-Breakers

AF40... AF96 3-pole contactors 30 to 60 hp at 480 V AC AC / DC operated with 1 N.O. + 1 N.C. auxiliary contacts

Thermal overload relay TF140DU and TF140DU-V1000

Protection Equipment. 5/2 Introduction

Description. Positive safety relays

NSL..S 4-pole / 8-pole Contactor Relays - Spring Terminals

AF09... AF38 4-pole Contactors AC / DC Operated - with Screw Terminals

B6, B7, BC6, BC7, TBC7 3- and 4-pole mini contactors VB6, VB7, VBC6, VBC7 3- and 4-pole mini reversing contactors Technical data

Siemens AG RW BB14 3RW BB14 3RW BB14. per PU three-phase induction opera- Rated Rated power of three-phase

Protective Devices: Circuit-Breakers 1 )

SENTRON Switching and Protection Devices Switch Disconnectors

Protection Equipment. Overload Relays. Reference Manual 04/2011. Industrial Controls. Answers for industry.

AF09... AF30 3-pole Contactors up to 25 HP / 600 VAC

Approved Standards. Ordering Information. Mini Motor Contactor J7KNA. Model Number Legend. Main contactor. Accessories. Mini Motor Contactor J7KNA 1

Technical Information

Application Mini Contactors for Motors and Resistive Loads

Micro Contactor MA Series

3SE3 1 SIGUARD Position Switches

1 3RT1016-1A**1 1 3RT1017-1A** RT1025-1A** RT1025-3A** RT1034-1A** RT1034-3A**0 175.

Thermal overload relay TF65 and TF96

Index. Manual Motor Starters 1. Auxiliary Contact Blocks 1. Trip Alarm Auxiliary 1. Switch. Shunt Release 1. Under-voltage Release 2.

Technical data for manual motor starters Type MS325

General_technical_data Series

MSW. MSW Catalog Number Sequence. Standard Features MSW 25 B- 3

VB6, VB7 3-pole mini reversing contactors with screw terminals 4 to 5.5 kw AC operated

Electronic overload relay EF65, EF96 and EF146

Electronic overload relays EF205 and EF370

Latch for Contactors 4-pole see page 36. Ratings Rated Aux. Contacts Type Coil voltage 2) AC2 Current Built-in Additional 24 24V= DC 5

Switch Disconnectors. SENTRON 3NP5 Fuse Switch Disconnectors up to 630 A. Introduction. 7/106 Siemens LV

AF / AF12Z pole Contactors AC / DC Operated - with Screw Terminals

DIN EN UL 508 / CSA 3RF A A 0 2

Solid State Relays, 3-phase

Approved Standards. Motor Contactor. Main contactor. Accessoires. 21 Motor Contactor J7KN

Residual Current Protective Devices / Arc Fault Detection Devices (AFDDs)

Item Code Description Quantity 3NA LV HRC FUSE LINK S00 80A 690AC 250DC 30 3NA3832 LV HRC FUSE LINK GL/GG S00 125A 500VAC 250VDC 0

AF / AF30Z stack 3-pole Contactors AC / DC Operated - with Screw Terminals

AF / AF16Z pole Contactors AC / DC Operated - with Screw Terminals

For Operation in the Control Cabinet

TAE pole Contactors

Manual Motor Starters. Meta-MEC

SIRIUS 3RV2 Motor Starter Protectors/Circuit Breakers up to 40 A Accessories Enclosures and front plates

The breakers offer thermal-magnetic trip protection according to Z and K characteristics.

AF / AF09Z pole Contactors AC / DC Operated - with Screw Terminals

UL & CSA Technical data A/AE9 A/AE/AF110, AL9 AL40 AC & DC operated

AF / AF09Z pole Contactors AC / DC Operated - with Screw Terminals

BETA Switching Switches and Light Indicators

TeSys contactors. Use in category DC-1 (resistive loads; time constant L/R y 1 ms) Rated operational current Ie. to be wired in series

W Datasheet: DIN Rail Contactors, series AMPARO

MODULAR DEVICES. 21. Isolator Switches. Low Voltage (Bell) Transformers. Time Switches (electromechanical)

AF / AF38Z pole Contactors AC / DC Operated - with Screw Terminals

Bulletin 193-T1 Bimetallic Overload Relays

DC/DC converters - MINI-PS DC/ 5-15DC/

27Overload Relays. Overview Combinations of overload relays and contactors SIRIUS 3R. Thermally delayed overload relays CLASS 10

AF09... AF30 3-pole Contactors up to 20 HP / 480 VAC

B115...B180 RF200 RFN200 B250...B400 RF400 RFN400

GV2, GV3, and GV7 Manual Motor Starters, Controllers, and Protectors Standard Features

Low-Voltage Controls and Distribution

Instructions Contact numbers to EN Coil terminal markings to EN Integrated diode-resistor combination Coil rating 2.

3TM Vacuum Contactors

Instructions Contact numbers to EN Coil terminal markings to EN Integrated diode-resistor combination Coil rating 2.

Short form catalogue. Motor protection & control

I r A short-circuit protective device: Observe the maximum permissible fuse of the contactor with direct device mounting.

4 - Miniature controls

3RW Soft Starters. General data. 6/4 Siemens LV 1 T 2006

RSC09 RSC16 RSC22 RSC38 RSC43 RSC63 RSC-AUX

Transcription:

Data sheet CONTACTOR, AC-3, 11KW/400V, 1NO+1NC, AC110V 50HZ, 120V 60HZ 3-POLE, SZ S0 SCREW TERMINAL product brand name Product designation SIRIUS 3RT2 contactor General technical data: Size of contactor S0 Product extension function module for communication No Auxiliary switch Yes Insulation voltage rated value 690 V Degree of pollution 3 Surge voltage resistance rated value 6 kv maximum permissible voltage for safe isolation between coil and main contacts acc. to EN 400 V 60947-1 Protection class IP on the front IP20 of the terminal IP20 Shock resistance at rectangular impulse Page 1/10 05.04.2016 Copyright Siemens AG

at AC 8,3g / 5 ms, 5,3g / 10 ms with sine pulse at AC 13,5g / 5 ms, 8,3g / 10 ms Mechanical service life (switching cycles) of contactor typical 10 000 000 of the contactor with added electronicscompatible auxiliary switch block typical 5 000 000 of the contactor with added auxiliary switch 10 000 000 block typical Ambient conditions: Installation altitude at height above sea level 2 000 m maximum Ambient temperature during operation -25... +60 C during storage -55... +80 C Main circuit: Number of NO contacts for main contacts 3 Number of NC contacts for main contacts 0 Operating voltage at AC-3 rated value maximum 690 V Operating current at AC-1 at 400 V at ambient temperature 40 C rated value 40 A at AC-1 up to 690 V at ambient temperature 40 C rated value 40 A at ambient temperature 60 C rated value 35 A at AC-2 at 400 V rated value 25 A at AC-3 at 400 V rated value 25 A at 500 V rated value 18 A at 690 V rated value 13 A Connectable conductor cross-section in main circuit at AC-1 at 60 C minimum permissible 10 mm² at 40 C minimum permissible 10 mm² Operating current for approx. 200000 operating cycles at AC-4 at 400 V rated value 9 A at 690 V rated value 9 A Operating current at 1 current path at DC-1 at 24 V rated value 35 A Page 2/10 05.04.2016 Copyright Siemens AG

at 110 V rated value 4.5 A at 220 V rated value 1 A at 440 V rated value 0.4 A at 600 V rated value 0.25 A with 2 current paths in series at DC-1 at 24 V rated value 35 A at 110 V rated value 35 A at 220 V rated value 5 A at 440 V rated value 1 A at 600 V rated value 0.8 A with 3 current paths in series at DC-1 at 24 V rated value 35 A at 110 V rated value 35 A at 220 V rated value 35 A at 440 V rated value 2.9 A at 600 V rated value 1.4 A Operating current at 1 current path at DC-3 at DC-5 at 24 V rated value 20 A at 110 V rated value 2.5 A at 220 V rated value 1 A at 440 V rated value 0.09 A at 600 V rated value 0.06 A with 2 current paths in series at DC-3 at DC-5 at 110 V rated value 15 A at 220 V rated value 3 A at 24 V rated value 35 A at 440 V rated value 0.27 A at 600 V rated value 0.16 A with 3 current paths in series at DC-3 at DC-5 at 110 V rated value 35 A at 220 V rated value 10 A at 24 V rated value 35 A at 440 V rated value 0.6 A at 600 V rated value 0.6 A Operating power at AC-1 at 230 V rated value 13.3 kw at 230 V at 60 C rated value 13.3 kw at 400 V rated value 23 kw at 400 V at 60 C rated value 23 kw Page 3/10 05.04.2016 Copyright Siemens AG

at 690 V rated value 40 kw at 690 V at 60 C rated value 40 kw at AC-2 at 400 V rated value 11 kw at AC-3 at 230 V rated value 5.5 kw at 400 V rated value 11 kw at 690 V rated value 11 kw Operating power for approx. 200000 operating cycles at AC-4 at 400 V rated value 4.4 kw at 690 V rated value 7.7 kw Thermal short-time current limited to 10 s 200 A Power loss [W] at AC-3 at 400 V for rated value of 1.6 W the operating current per conductor No-load switching frequency at AC 5 000 1/h Operating frequency at AC-1 maximum 1 000 1/h at AC-2 maximum 750 1/h at AC-3 maximum 750 1/h at AC-4 maximum 250 1/h Control circuit/ Control: Type of voltage of the control supply voltage AC Control supply voltage at AC at 50 Hz rated value 110 V at 60 Hz rated value 120 V Operating range factor control supply voltage rated value of magnet coil at AC at 50 Hz 0.8... 1.1 at 60 Hz 0.85... 1.1 Apparent pick-up power of magnet coil at AC at 50 Hz 81 V A at 60 Hz 79 V A Inductive power factor with closing power of the coil at 50 Hz 0.72 at 60 Hz 0.74 Apparent holding power of magnet coil at AC at 50 Hz 10.5 V A at 60 Hz 8.5 V A Inductive power factor with the holding power of the coil at 50 Hz 0.25 Page 4/10 05.04.2016 Copyright Siemens AG

at 60 Hz 0.28 Closing delay at AC 8... 40 ms Opening delay at AC 4... 16 ms Arcing time 10... 10 ms Residual current of the electronics for control with signal <0> at AC at 230 V maximum permissible 7 ma at DC at 24 V maximum permissible 16 ma Auxiliary circuit: Number of NC contacts for auxiliary contacts instantaneous contact 1 Number of NO contacts for auxiliary contacts instantaneous contact 1 Operating current at AC-12 maximum 10 A Operating current at AC-15 at 230 V rated value 10 A at 400 V rated value 3 A at 500 V rated value 2 A at 690 V rated value 1 A Operating current at DC-12 at 24 V rated value 10 A at 48 V rated value 6 A at 60 V rated value 6 A at 110 V rated value 3 A at 125 V rated value 2 A at 220 V rated value 1 A at 600 V rated value 0.15 A Operating current at DC-13 at 24 V rated value 10 A at 48 V rated value 2 A at 60 V rated value 2 A at 110 V rated value 1 A at 125 V rated value 0.9 A at 220 V rated value 0.3 A at 600 V rated value 0.1 A Contact reliability of auxiliary contacts 1 faulty switching per 100 million (17 V, 1 ma) UL/CSA ratings: Page 5/10 05.04.2016 Copyright Siemens AG

Full-load current (FLA) for three-phase AC motor at 480 V rated value 21 A at 600 V rated value 22 A Yielded mechanical performance [hp] for single-phase AC motor at 110/120 V rated value 2 hp at 230 V rated value 3 hp for three-phase AC motor at 200/208 V rated value 5 hp at 220/230 V rated value 7.5 hp at 460/480 V rated value 15 hp at 575/600 V rated value 20 hp Contact rating of auxiliary contacts according to UL A600 / Q600 Short-circuit protection Design of the fuse link for short-circuit protection of the main circuit with type of coordination 1 required gl/gg LV HRC 3NA, DIAZED 5SB, NEOZED 5SE: 100 A with type of assignment 2 required gl/gg LV HRC 3NA, DIAZED 5SB, NEOZED 5SE: 35 A for short-circuit protection of the auxiliary switch fuse gl/gg: 10 A required Installation/ mounting/ dimensions: Mounting position +/-180 rotation possible on vertical mounting surface; can be tilted forward and backward by +/- 22.5 on vertical mounting surface Mounting type screw and snap-on mounting onto 35 mm standard mounting rail according to DIN EN 50022 Side-by-side mounting Yes Height 85 mm Width 45 mm Depth 97 mm Required spacing with side-by-side mounting forwards 0 mm Backwards 0 mm upwards 0 mm downwards 0 mm at the side 0 mm for grounded parts forwards 0 mm Backwards 0 mm upwards 0 mm at the side 6 mm Page 6/10 05.04.2016 Copyright Siemens AG

downwards 0 mm for live parts forwards 0 mm Backwards 0 mm upwards 0 mm downwards 0 mm at the side 6 mm Connections/ Terminals: Type of electrical connection for main current circuit screw-type terminals for auxiliary and control current circuit screw-type terminals Type of connectable conductor cross-sections for main contacts solid 2x (1... 2.5 mm²), 2x (2.5... 10 mm²) single or multi-stranded 2x (1... 2,5 mm²), 2x (2,5... 10 mm²) finely stranded with core end processing 2x (1... 2.5 mm²), 2x (2.5... 6 mm²), 1x 10 mm² at AWG conductors for main contacts 2x (16... 12), 2x (14... 8) Type of connectable conductor cross-sections for auxiliary contacts single or multi-stranded 2x (0,5... 1,5 mm²), 2x (0,75... 2,5 mm²) finely stranded with core end processing 2x (0.5... 1.5 mm²), 2x (0.75... 2.5 mm²) at AWG conductors for auxiliary contacts 2x (20... 16), 2x (18... 14) Safety related data: B10 value with high demand rate acc. to SN 31920 1 000 000 Proportion of dangerous failures with low demand rate acc. to SN 31920 40 % with high demand rate acc. to SN 31920 73 % Failure rate [FIT] with low demand rate acc. to SN 31920 100 FIT Product function Mirror contact acc. to IEC 60947-4-1 Yes T1 value for proof test interval or service life acc. to 20 y IEC 61508 Certificates/approvals Page 7/10 05.04.2016 Copyright Siemens AG

General Product Approval KTL EMC Functional Safety/Safety of Machinery Declaration of Conformity Test Certificates Shipping Approval Baumusterbescheini gung spezielle Prüfbescheinigunge n Typprüfbescheinigu ng/werkszeugnis Shipping Approval other Umweltbestätigung Bestätigungen Further information Information- and Downloadcenter (Catalogs, Brochures, ) http://www.siemens.com/industrial-controls/catalogs Industry Mall (Online ordering system) https://mall.industry.siemens.com/mall/en/en/catalog/product?mlfb=3rt20261ak60 Cax online generator http://support.automation.siemens.com/ww/caxorder/default.aspx?lang=en&mlfb=3rt20261ak60 Service&Support (Manuals, Certificates, Characteristics, FAQs,...) https://support.industry.siemens.com/cs/ww/en/ps/3rt20261ak60 Image database (product images, 2D dimension drawings, 3D models, device circuit diagrams, EPLAN macros,...) http://www.automation.siemens.com/bilddb/cax_de.aspx?mlfb=3rt20261ak60&lang=en Page 8/10 05.04.2016 Copyright Siemens AG

1 / L1 3 / L2 5 / L3 3. 4. 5. 6. 5 45 97 35.1 4.8 7.5 2.5 85 75 43 5 5 Page 9/10 05.04.2016 Copyright Siemens AG

-Q A1 1 /L1 3 /L2 5 /L3 13 21 A2 2 /T1 4 /T2 6 /T3 14 22 last modified: 21.03.2016 Page 10/10 05.04.2016 Copyright Siemens AG