Operating instructions Actuator and Emergency exit AZ/AZM 200-B30 AZ/AZM 201-B About this document. Content

Similar documents
Operating instructions Solenoid interlock TKM/TKF. 1. About this document. Content

Operating instructions Solenoid interlock AZM 161../.. 1. About this document. Content

Operating instructions Solenoid interlock EX-AZM About this document. Content

Operating instructions Safety sensor BNS About this document. Content. 6 Disassembly and disposal 6.1 Disassembly Disposal...

Operating instructions Solenoid interlock AZM 161../.. 1. About this document. Content

Operating instructions Solenoid interlock AZM /.. 1. About this document. Content

Operating instructions Switching cushion with safety function SSG-SK. 1. About this document. Content

Operating instructions Trapped key system SHGV / SVE / SVM. 1. About this document. Content

Operating instructions Pull-wire emergency-stop switches EX-ZQ About this document. Content

Operating instructions Safety sensor EX-CSS About this document. Content. 7 Disassembly and disposal 7.1 Disassembly Disposal...

Operating instructions Solenoid interlock AZM About this document. Content

Operating instructions Solenoid interlock AZM 170

Operating instructions Safety foot switches T.FH UEDR.. 1. About this document. Content

Encontrará el manual de instrucciones actual en su idioma oficial de la UE en nuestra página de Internet www. schmersal.net.

Operating instructions Solenoid interlock AZM About this document. Content

Encontrará el manual de instrucciones actual en su idioma oficial de la UE en nuestra página de Internet www. schmersal.net.

Operating instructions Solenoid interlock AZM About this document. Content

Safety door-handle system STS

Solenoid interlock AZM 200 The non-contact interlock.

Solenoid interlocks AZM 161 range Schmersal. a 5,5. Pg11/M16x1,5

AC 100. Operating instructions Pneumatic Crimper AC 100. Date of issue: 05/2010. Keep for future use!

Technical data. Standards: IEC/EN , EN ISO , IEC 61508, IEC

AZM 161SK 12/12RKED/TU 024

HST -LS Interlocking device (Translation of Original Manual)

Ordering details. Approval. Classification. Global Properties :18:33h. Solenoid interlock / AZM 161

Assembly and Maintenance Manual Type ASNU

Operating instructions Rotary actuators M135 M140 M150 M180. June 2012 / / EN

Technical data. Standards: IEC/EN ; EN ISO ; EN 1088; BG-GS-ET-19

Solenoid interlocks AZM 170 range. 98 Schmersal 22 8,2 60. ø4,2. ø Pg 11

Operating and Maintenance Manual. for. HADEF overhead crane. as jointed crane TA

Datasheet - AZ ZUEK Safety switch with separate actuator / AZ 3350

Assembly and Maintenance Manual Type AS

Turbocharger / TPS-H Original assembly instructions English

Solenoid interlocks AZM 415 range. 134 Schmersal 29,5 6,5 24,7. 8,6 Pg 13,5 46,5 24,5

Exchange of rollers from the XTS-Mover

SERVO MOTORS BRUSHLESS SERVO MOTORS OPERATING INSTRUCTIONS 2016

Timing-Belt Reverse Unit 8 80 R25 Notes on Use and Installation

Rotary feed-through DDF-S/-KS

Operating Instructions

Turbocharger / VTR..0, VTR..1 Original assembly instructions English

Ordering designation: G(Type) - (Stroke) - (Eye bolt) - (Cable length) - (Options) Legend:

EC MACHINE DIRECTIVE COMPLIANCE DECLARATION

Bowl feeder WV401-1 / Translation of operating and installation instructions

Turbocharger / A100-L Original assembly instructions English

Assembly and Maintenance Manual Type RSBW

Pressure relief valve

Operating Instructions

Installation and Operating Manual for Tank and Equipment Cleaning Nozzles Series 5TM

Installation and Service Instructions (Translation of the Original Instructions) SV120. C _EN 11/2009 Rev.0

Ex m Solenoid Operator Type 0519

Instruction manual Electric glass door lock Touch-to-open

EC MACHINE DIRECTIVE COMPLIANCE DECLARATION

PIX. Operation - Replacement of Fuses Replacement of Voltage Transformers Technical manual. Medium Voltage Distribution

Quick-Disconnect Coupling one-hand operation Push Pull ND 5, connecting thread G 1/4,max. operating pressure 500 bar

Safety Sensor CSS 180 Product Information

Support T10552 T10595 T40386

AZM300 More than just a solenoid interlock

Operating Instructions

Spare Parts List Tank-Top Return Line Filter RFN with Elements to DIN up to 630 l/min, up to 10 bar

ZB0050 / ZB0051 ZB0070 / ZB0071

MKey9-series Safety Interlock Switch with Guard Locking

Mounting and Operating Instructions EB 3913 EN. Electropneumatic Converters i/p Converter Type

Guard locking systems for the protection of man and machine

Operating Instructions Flexdip CYA112

CO 3-WAY PNEUMATIC VALVE INSTRUCTION MANUAL 2080

GKR/GKL Series Dual Entry Solenoid Key Operated Safety Interlock Switch

Under the aspect of simplified

Compensation unit AGE-XY 50-80

Siemens Drives & PLCs

Datasheet - TV8S /20Z Safety switch for hinged guards / Hinge safety switch / TV8S 521

Mechanical seals external, single or double type Crane 58U 58U

The vehicle manufacturer's body fitting guidelines must be adhered to and AMF-Bruns original parts need to be used for the installation!

Declaration of Conformity as per Directive 97/23/EC

Operating instructions

Operating Instructions

3700/8700/8800 Rim Exit Device Owner s Manual

General operating manual for assembly, commissioning and maintenance of valves and hydraulic manifolds

Checking the usage. Slow opening/slow closing damping unit:

Braking Module / braking resistor SINAMICS. SINAMICS G130 Braking Module / braking resistor. Safety information 1. General. Mechanical installation

Operating Instruction. Junction Box 80 A/125 A. Part-Number BAL a-EN Original document page 1 of 20

Tina 4A Connection block

Operating Instructions

Original Operating Manual

CENTAX-TEST Assembly and operating instructions 053C GB3. M EN Rev. 1

A company of ThyssenKrupp Elevator. ThyssenKrupp Aufzugswerke. Operating Manual. Oil buffer

CENTAFLEX-K Assembly and operating instructions 014K S... M EN Rev. 1

SMB. Assembly and operating instructions Sprinkler measuring orifice SMB/SMB-OE. Sprinkler measuring orifice

Assembly instructions PRORUNNER mk1 2

The vehicle manufacturer's body fitting guidelines must be adhered to and AMF-Bruns original parts need to be used for the installation!

KeContact P20. User manual

Sense7-series Non-contact coded safety switch

Translation of the Original operating instructions Lifting device Z 70 /...

Spare Parts List Return line filter RF

Original Operating Manual

Installation Guide. RunLock. NISSAN Navara D40. Art.Nr. B

OPERATOR S HANDBOOK TRADITIONAL CLASSIC 1502 RLH 1002 RLH 1502 REPLACES. Kit : November 1997

OPERATING INSTRUCTIONS Thread unscrewing unit Z 5410, Z5420, Z5430

Installation manual wall-mounted distributor

HS1E Series Full Size Interlock Switch with Locking Solenoid

F3S-TGR-KHL1/-KHL3/-KHL3R

Transcription:

1. About this document Operating instructions............pages 1 to 10 Original 1.1 Function This operating instructions manual provides all the information you need for the mounting, set-up and commissioning to ensure the safe operation and disassembly of the the product. he operating instructions must be available in a legible condition and a complete version in the vicinity of the device. 1.2 Target group: authorised qualified personnel All operations described in this operating instructions manual must be carried out by trained specialist personnel, authorised by the plant operator only. Please make sure that you have read and understood these operating instructions and that you know all applicable legislations regarding occupational safety and accident prevention prior to installation and putting the component into operation. The machine builder must carefully select the harmonised standards to be complied with as well as other technical specifications for the selection, mounting and integration of the components. 1.3 Explanation of the symbols used Information, hint, note: This symbol is used for identifying useful additional information. Caution: Failure to comply with this warning notice could lead to failures or malfunctions. Warning: Failure to comply with this warning notice could lead to physical injury and/or damage to the machine. x.000 / 01.2017 / v.a. - 103013249- / A / 2017-01-24 / AE-Nr. - Content 1 About this document 1.1 Function...11 1.2 Target group: authorised qualified personnel....11 1.3 Explanation of the symbols used...11 1.4 General safety instructions...11 1. Warning about misuse...11 1.6 Exclusion of liability...11 2 Product description 2.1 Ordering code...12 2.2 Special versions....12 2.3 Destination and use...12 3 Mounting 3.1 General mounting instructions...12 3.2 Representation of installation options...12 3.3 Dimensions...13 3.4 Sequence of the steps...1 4 Appendix 4.1 Set-up checklist...19 1.4 General safety instructions The user must observe the safety instructions in this operating instructions manual, the country-specific installation standards as well as all prevailing safety regulations and accident prevention rules. Further technical information can be found in the Schmersal catalogues or in the online catalogue on the Internet: www.schmersal.net. The information contained in this operating instructions manual is provided without liability and is subject to technical modifications. There are no residual risks, provided that the safety instructions as well as the instructions regarding mounting, commissioning, operation and maintenance are observed. 1. Warning about misuse In case of inadequate or improper use or manipulations of the component, personal hazards or damage to machinery or plant components cannot be excluded. The relevant requirements of the standard ISO 14119 must be observed. 1.6 Exclusion of liability We shall accept no liability for damages and malfunctions resulting from defective mounting or failure to comply with this operating instructions manual. The manufacturer shall accept no liability for damages resulting from the use of unauthorised spare parts or accessories. For safety reasons, invasive work on the device as well as arbitrary repairs, conversions and modifications to the device are strictly forbidden; the manufacturer shall accept no liability for damages resulting from such invasive work, arbitrary repairs, conversions and/or modifications to the device. 1

2. Product description 2.1 Ordering code This operating instructions manual applies to the following types: -➀T➁➂➃-➄ AZ/201-B30-➀T➁➂➃-➄ No. Option Description ➀ L Door hinge on left-hand side R Door hinge on right-hand side ➁ A For mounting outside I mounting inside ➂ G1 with handle G2 with rotating knob ➃ P1 with emergency exit P20 with emergency exit metal * P2 with emergency exit inset handle * P30/P31 with locking rod * ➄ without lockout tag SZ with lockout tag * 3. Mounting 3.1 General mounting instructions The installation may only be carried out by authorised personnel. Admissible mounting set-up Inadmissible mounting set-up * Only for mounting outside The actuator unit... is intended exclusively for combination with the AZ/ 200 series basic component. The actuator unit AZ/201-B30... is intended exclusively for combination with the AZ/201 series basic component. Only if the information described in this operating instructions manual are realised correctly, the safety function and therefore the compliance of the entire system with the Machinery Directive is maintained. 2.2 Special versions For special versions, which are not listed in the order code below 2.1, these specifications apply accordingly, provided that they correspond to the standard version. 3.2 Representation of installation options Actuators and AZ/201-B30 are available for either exterior or interior installation. For out use, the safety switchgear AZ/ 200 or AZ/ 201 is placed outside the hazardous area, for in use it is placed within the hazardous area. 2.3 Destination and use In conjunction with the solenoid interlock or switch, the actuator unit is suitable for and sliding safety guards. The safety guard can be opened and closed from outside by turning the -handle. Holding force F max - mounting outside 2000 N - mounting inside 1000 N With emergency exit Right Left Right Left The actuator is pulled into the actuator unit by a spring. The actuator unit with emergency exit is used to open the safety guard inside the hazardous area. By actuating the emergency exit, the safety guard can be opened from within the hazardous area without the need for unlocking the solenoid interlock. The safety guard cannot be locked from inside. On accessible protective equipment, the lockout tag prevents persons from being inadvertently being trapped. When entering the hazardous area, each member of the operating or service team fixes a lock to the lockout tag to prevent the locking of the safety guard and therefore any inadvertent machine start. Without emergency exit Right Left Actuator unit play X = ± 1. mm Y = ±.0 mm Z = ± 1.0 mm The minimum radius of the when mounting outside is 400 mm, mounting inside 700 mm. Assumptions: - 40 mm Profile Distance between solenoid interlock and actuator unit 7. mm - Use standard hinge for 40 mm profile 2

3.3 Dimensions All measurements in mm. 200 and 201 with actuator unit mounted outside the hazardous area 81 43, 40, 7, +0, -2, A 7, 200 and 201 with emergency exit P1 mounted within the hazardous area 81 43, 40, 7, +0, -2, 7, 88 13, 220 78 32, 48 1, 3 10 13, 88 220 78 32, 3 1, 49. 16 B 40 B 40 Inside K Outside J 94 68 0 2 max. 170 94 68 0 2 max. 170 Outside 7, J Inside 7, K Interior view: Emergency exit P1 47, 73 7, 3 +0, -2, 7, Exterior view: Actuator unit with handle 47, 73 7, +0, -2, 3 220 18, 220 18, 7, 6 6 78 1, 78 32, 18,7 32, 1, A SZ 40 40 Key A = Manual release B = Cable entry M20 x 1. J = Actuator unit with -handle G1 K = Emergency exit P1 SZ = Lockout tag (optional, ordering suffix -SZ) 3

Instead of the handle G1 a rotating knob G2 can be optionally be used. Rotating knob G2 Accessories The lockout tags SZ 200 and SZ 200-1 are optional as additional lockout tags for in and out assembly are available. Lockout tag SZ 200 8x8 ø18 78 8 79-8 37 3,9 41 9 136 4 160 6,3 Instead of the emergency exit P1 the following emergency exits can be used for out assembly. 3 12, Emergency exit (metal) P20 87, 19 81 37 Emergency exit inset handle P2 7 60 6 9 7 ø88 ø18 ø80 2 1 Lockout tag SZ 200-1 107 23, 2 37 281-331 10 6 8 12. Ø4 3, t=3mm Ø10 13, 29 9 23 18 14 2 4

3.4 Sequence of the steps The following work instructions are valid for both in and out assembly. If there are any differences with the versions these are indicated with notes or additional sketches. Step 3 For mounting outside: Unscrew the cover of the actuator unit For mounting inside: Unscrew the cover of the emergency exit P1 Step 1 To free mounting holes unscrew the cover C for the wiring compartment and open flap A for the manual release. For exterior installation: Actuation of manual release (beneath flap) with triangular key (included in delivery) For interior installation: Actuation of manual release using triangular key (included in delivery) on back A Step 4 Insert sliding blocks (included in delivery with actuator unit AZ/) as shown. Observe the alignment (notch) of the sliding blocks E = Left D = Right GN RD YE C E D Step Step 2 Enclosure of safety switchgear AZ/ 200 and AZ/201 mounted flush with post. For mounting inside: An additional access hole Z Ø10 mm is necessary for the manual release to allow external access. Screws DIN 912-M6 Max. tightening torque for safety switchgear = 8 Nm, cover screw = 0.7 1 Nm (Torx T10) Wall thickness of the device 19 mm Washers DIN 12-6.4 (included in delivery) For applications with strong vibrations, please observe the screws are correctly secured. For mounting outside: Fit the actuator unit to the post by means of the spacer F: (7, mm) For mounting inside: Fit the emergency exit P1 to the post by means of the spacer F: (7, mm) Actuator unit or emergency exit completely retracted Distance between solenoid interlock and actuator unit or emergency exit = 7. +0./-2. mm Screws DIN 912-M6 Torque MA = 8 Nm Wall thickness of the device 8 mm (see step 11) Washers DIN 12-6.4 (included in delivery) For applications with strong vibrations, please observe a proper securing of the screws 19 Z F GN RD YE GN RD YE

Step 6 For mounting outside: Mount the cover on the actuator unit For mounting inside: Mount the cover on the emergency exit P1 Actuator unit or emergency exit completely retracted Step 9 For mounting outside: Unscrew the cover of the emergency exit P1 For mounting inside: Unscrew the cover of the actuator unit Step 7 For mounting outside: Fit the -handle For mounting inside: Fit the emergency exit handle Mount the handle or emergency release P1 horizontally D = for left s E = for right G = Hexagonal screw A/F 3 with screw-lock (included in delivery) For out installation without emergency exit continue to paragraph 17 Sticker included in delivery of lockout tag. Step 10 Insert sliding blocks as shown (included in delivery) Observe the alignment (notch) of the sliding blocks D = for left E = for right D E Step 8 D G SZ E If an emergency exit is available, cut square tube H at length. De-burr the cut sides. Max. leaf thickness S = 170 mm Length of sawn off square rod H P1: L = S + 22-2 mm P20: L = S + 28 mm P2: L = S + 24 mm P30/P31: L = S + 0 mm E G P1: L = S + 22-2 mm Through-hole for square tube H Ø 16 mm D Step 11 For mounting outside: Fit the bottom plate of the emergency exit P1 to the For mounting inside: Fit the bottom plate of the actuator unit to the Actuator completely in J (actuator unit or emergency exit unit) retracted Arrange both the emergency exit and the actuator unit parallel Screws DIN 912-M6 Torque MA = 8 Nm Wall thickness of the device 8 mm Washers Ø 6.4 DIN 12 (included in delivery) For applications with strong vibrations, please ensure the screws are correctly secured. 8 8 J K 8 8 J K H H For mounting outside and assembly with emergency exit P20 continue from paragraph 14 emergency exit P2 continue from paragraph 1 locking linkage P30 or P31 continue from paragraph 16 6

Step 12 For mounting outside: Insert square rod H in the backside of the actuator unit For mounting inside: Insert square rod H in the backside of the emergency exit P1 For mounting outside: Insert chamfer of square into emergency exit or insert cut side of square into actuator unit. Position of the chamfer as shown, when actuator unit is actuated. Step 14 - Mounting emergency exit P20 Only for mounting outside! Fit emergency exit P20 to the. Observe the position of the slotted hole Actuator completely inserted into the actuator unit J Emergency exit P20 parallel to actuator unit J Screws DIN 912-M6 Torque MA = 8 Nm Wall thickness of the device 8 mm Washers Ø 6.4 DIN 12 (included in delivery) For applications with strong vibrations, please observe a proper securing of the screws After the assembly of the emergency exit P20, proceed with step 17 H H For left Step 13 For mounting outside: Fit the cover and the handle onto the emergency exit For mounting inside: Fit the cover and the handle onto the actuator unit Position of the driving shaft I as shown, when actuator unit is actuated Functional test of the emergency exit handle: it should be possible to open the safety guard inside the hazardous area; it should not be possible to lock the safety guard from inside. The emergency exit handle must be in upright position when closed. After successful assembly continue from paragraph 17 For left I I For right Step 1 - Mounting emergency exit P2 Only for mounting outside! Fit emergency exit P2 to the. Observe the position of the slotted hole Actuator completely inserted into the actuator unit J Emergency exit P2 parallel to actuator unit J Screws DIN 912-M6 Torque MA = 8 Nm Wall thickness of the device 8 mm For applications with strong vibrations, please observe a proper securing of the screws After the assembly of the emergency exit P2, proceed with step 17 For right I I For left For right 7

Step 16 - Mounting of the P30 or P31 locking rod Only for mounting outside! Fit the locking rod without emergency exit P30 either with emergency exit P31. See operating instructions -P30/P31 and AZ/201-B30-P30/P31 Step 18 After being put into operation, the manual release must be secured by installing the seal, which is included in delivery. For mounting outside: Seal the cover of the manual release A For mounting inside: Secure the access hole for the auxiliary release A with a seal A GN RD YE Step 17 Clip the dust-proof flap in the unused side. D = for left E = for right E D GN RD YE 8

4. Appendix 4.1 Set-up checklist Checklist Set-up and maintenance Checking safety handle system AZ/ 200 and AZ/ 201 Within the scope of commissioning and regular maintenance of the machine, the following items of the safety -handle system, consisting of 200 or AZ/ 201, the corresponding actuator unit and the emergency exit must be checked and inspected by a specialist: 1. Fixation: All fixing screws installed and tightened with the specified torque 2. Distance: Distance 7. +0./-2. mm between safety switchgear AZ/ 200 or AZ/201 and actuator unit must be adhered to. 3. Emergency exit handle: After locking, the correct closing of the must be checked. It should be possible to open the safety guard inside the hazardous area; it should not be possible to lock the safety guard from inside It should be possible to open the safety guard inside the hazardous area; it should not be possible to lock the safety guard from inside. The emergency exit handle must be in the upright position when closed. 4. Sticker emergency exit handle (included in delivery): The sticker is visibly attached.. Dust shield cap: Check tight fitting of the dust-proof flap 6. Functional testing: The enabling signal is only transmitted to the safety circuit, if the actuator is within range of the solenoid interlock and locked. LED green yellow flashes yellow red STATUS Operating voltage Actuator inserted (and locked for 200 or 201) Actuator inserted and not locked (only for 200 or 201) Error 7. Cover for manual release: Access cover or access hole is sealed (only for 200 or 201). Date / Signature: 9

K. A. Schmersal GmbH & Co. KG Möddinghofe 30, D - 42279 Wuppertal Postfach 24 02 63, D - 42232 Wuppertal Phone: +49 - (0)2 02-64 74-0 Telefax: +49 - (0)2 02-64 74-1 00 E-Mail: info@schmersal.com Internet: http://www.schmersal.com