Remote reading dial thermometers, version for industry

Similar documents
Dial thermometers. Gas filled system and Bi-metal. dial thermometers

Diesel engine dial thermometers

Diesel engine dial thermometers

Diesel engine dial thermometers

Mechanical Measuring Instruments

Gas Actuated Thermometers Stainless Steel Series, Model 73

Bimetal Thermometers Process Industry Series, Model 55

KombiTemp. Head form B / Head form J Cable socket, angle type Diesel engine dial thermometers. Temperature Sensors with local display

Process Connections for Dial Thermometers

Bimetal Thermometers Model 54, Heavy Duty Series

Gas-actuated thermometer with switch contacts Model 73, stainless steel version

Gas-actuated thermometer Model 73, stainless steel version

Measuring Instruments for Marine Applications

Bimetal thermometer Model 52, industrial series

Bimetal thermometer with Pt100 electrical output signal Model 54, stainless steel version

Contact dial thermometer

TZ04. Dial Thermometer (nitrogen-filled gauge) Temperature Measurement and Monitoring. Housing sizes from 63 to 250 mm. Stainless steel housing

Gas-actuated thermometer with switch contacts Stainless steel version Model 73

Mechanical pressure gauges

Bimetal thermometer Model 52, industrial series

Precision Bourdon tube pressure gauges

Gas-actuated thermometer Highly vibration resistant Model 75, stainless steel version

Electronic Monitoring Systems

THERMOMETERS FOR TRANSFORMERS

Absolute pressure gauge with switch contacts For the process industry, NS 100 and 160 Models , and

Electronic Monitoring Systems

Machine glass thermometers Model 32, V-Form

TBM. Bi-Metal Thermometer

INDUSTRIAL THERMOMETER

Air duct thermometers. Bimetal thermometers. Industrial thermometers. Resistance thermometers

INDUSTRIAL THERMOMETER

Head form B Head form J Cable socket, angle type KOMBITEMP TEMPERATURE SENSOR WITH LOCAL DISPLAY. Including products with:

* * Data sheet DA A (ATEX) Differential pressure measuring device for potentially explosive areas

Contact Dial Thermometer

Industrial Thermometers

Differential Pressure Gauge

k Applications Bourdon tube pressure gauge with switch contacts For the process industry, NS 100 and 160 Models PGS and PGS23.

Capillary Thermometers according to DIN Nitrogen Filled Option: Contacts

Resistance thermometer with digital indicator Model TR75, battery operation

300/400/ /900 SERIES

Differential Pressure Gauges (701P Series)

ELECTRONIC MONITORING SYSTEMS AND TEMPERATURE SENSORS

Resistance thermometer with digital display Model TR75, battery operation

Direct immersion resistance thermometer

Resistance Thermometers Model TR217, with Spring-Loaded Probe Tip

ZEAL The Gauge of Quality PRECISION BIMETAL DIAL THERMOMETERS

TWL-Exia. Resistance Thermometers according to DIN. Ignition Protection Exia. Pt 100-sensor class A respectively class B

TSS Gas filled thermometer

2014 /2015. Product Overview. Instrumentation and Control. Temperature Measurement and Monitoring

Thread Mounted Resistance Thermometers Model TR201, with Fabricated Thermowell

Differential pressure gauge with switch contacts For the process industry, all-metal media chamber Models DPGS43.100, DPGS43.160

Liquid filled Thermometers

Gas-actuated thermometer with switch contacts For sanitary applications, stainless steel version Model 74

Push-in RTD Temperature Probe with Connecting Cable

Differential pressure gauge with switch contacts For the process industry Models DPGS43HP.1x0, high overload safety up to 40, 100, 250 or 400 bar

TEMPERATURE CONTROL AND MONITORING HYDRAULIC COMPONENTS

Bourdon tube pressure gauge with switch contacts Stainless steel case Model PGS21, NS 100 and 160

Application The DA03 serves as indicator of differential. Follow mounting instructions in accordance to application.

NGS. Dual-Magnet Float Switch. Pressure: up to 25 bar. Density: > 0.7 kg/dm 3. High switch capacity. Material: stainless steel 1.

Differential pressure gauge with diaphragm

Self-operated Temperature Regulators Temperature Regulator Type 1u

TBM. Bi-Metal Thermometer

Series TNS/TNF Thermometers Installation/Operation Instructions

Differential pressure gauges with Bourdon tube

Stem Thermometers according to DIN Nitrogen Filled / Optional: Contacts

BALL VALVES FILTERS TEST POINTS 8

Heading 8. Mechanical Temperature Measurement. 03/18 ARMATURENBAU GmbH MANOTHERM Beierfeld GmbH

ENGLISH Datasheet Platinum Resistance Pt100 4 wire class B Resistance Thermometer with Compact KNS Head

THERMASGARD TF 43 THERMASGARD TF 65

Self-operated Temperature Regulators Type 1u Temperature Regulator

0190 / Tolerance in psi (bar) at room temperature. Adjustment range in psi (bar) psi. ± 2.90 psi. (± 0.2 bar) (0.3-1.

Duplex pressure gauge per DIN Panel mounting series for rail-vehicle braking systems Model PG21DPB, NS 60, 80, 100 and 130

WINTERS ( )

MAN-P. Diaphragm Pressure Gauges. according to EN for Stringent Demands

MESSKO COMPACT SERIES OIL TEMPERATURE ORDERING SPECIFICATIONS.

BALL VALVE SERIES Electric actuator - El-O-matic

Series 430 Type 3430 Pneumatic Indicating Controller for Temperature with Capillary Sensor Type 3432 Controller Station Type 3436 Transmitter Module

Pressure Gauge. Bourdon Tube Pressure Gauges with Switch Contacts Models MBSA, Stainless Steel Version. Applications. Special Features.

BALL VALVE SERIES Electric actuator - El-O-matic

SITRANS T measuring instruments for temperature

* * Data sheet MA15F... A/B/C/D. Diaphragm manometer for explosive areas

* * Data sheet DA01 VUW (ATEX) Differential pressure measuring device Pressure levels PN250/PN400. Models for use in explosive areas

Differential pressure gauge For the process industry Models , , high overload safety up to 40, 100 or 400 bar

TEMPERATURE REGULATORS W91/W94 Series

Data Sheet * * Differential pressure - Measuring device Pressure levels PN40/PN100. Important features. Application scopes

Absolute pressure gauge with diaphragm

TNS. Stem Thermometers according to DIN EN nitrogen filled option: contacts. Environmentally-friendly measuring system with non-toxic nitrogen

display on the wall or in a panel away from the inline sensor SE30 for easy meter reading.

Factor 1) Modulating torque 4) [Nm] 200 F14 G1/2 GK : :

Bourdon tube pressure gauge, copper alloy Panel mounting series Models and

Surface thermocouple Model TC50

1 (25mm): Acrylic Others: Glass standard, hermetically sealed

Pneumatic Controller for Temperature. Type Pneumatic Controller for Temperature. Type Mounting and Operating Instructions EB 7065 EN

Temperature Measurement Resistance thermometers

Process Industry. Specification Guide. For. Pressure & Temperature Instruments & Related Accessories

Differential-Pressure Flow Meter

Cable resistance thermometer Model TR40

Bourdon tube pressure gauge with switch contacts Models PGS23.1x0, stainless steel version

Magnetic float switch For vertical installation Model FLS (models with Ex approval: 60, AL-ADF)

Thermal hysteresis 0.5% max. of full scale (within compensated temperature range) 1% max. for ranges mbar mbar mbar

Transcription:

Remote reading dial thermometers, version for industry Type 313 WH, 323 TA, 333 TE and 334 KL Measuring system Nitrogen filled Type 313 WH Accuracy (EN 13190) Class 1 Case Crimped-on ring, stainless steel 1.4301 Degree of protection (EN 60529) IP65 Nominal sizes 63, 80, 100, 160 mm Mechanical design Thermometer with capillary line Connection position: Bottom, central back Mounting flange: With wall bracket, rear mounting flange, front mounting flange, with U bracket Capillary Stainless steel Ø 2 mm, with spiral anti-kink sleeves at both ends Capillary length selectable from 1 m to 15 m Display ranges (EN 13190) Measuring ranges 80 to 600 K Immersion tube Stainless steel 1.4571 Max. static working pressure: 25 bar Connection types: A, AK, Da, DN, SN Immersion tube diameter: 8, 10 or 12 mm Immersion tube length: up to max. 2.50 m Window Instrument glass Pointer movement German silver / brass Dial Aluminium, white with black scale markings Pointer Aluminium, black Display correction (±6 %) Externally accessible screw Special versions Case filling (silicone oil) Other immersion tube diameters, connection types and materials available on request Capillary > 15 m on request Other scale ranges and / or special scales, e.g. dual scale C / F, coloured zones or ranges, dial labelling, etc. Accessories Mechanical: see thermometer protection tubes section Please observe the relationship between the minimum immersion tube length and the active length (ET) and connection type. 54

Dimensions and weights Type 313 WH (with wall bracket) Wall bracket Weight [kg] (approx.) NS a b D D1 d7 s4 unfilled filled 63 12 39 67 62 26 8 0.36 0.44 80 15 42 86 79 26 8 0.45 0.59 100 15 43 106 99 26 10 0.57 0.76 160 15 51 167 159 26 11 0.88 1.59 * Details concerning wall brackets can be found in the chapter accessories. This information is provided as an example and relates to the version with connection type A or AK, Ø 10 mm, and immersion tube length 200 mm and capillary 1 m. 55

Type 323 TA (rear mounting flange, capillary outlet bottom) Type 323 (rear mounting flange, capillary outlet central back)* Weight [kg] (approx.) NS a1 b2 b3 D d1 d2 d3 s s4 unfilled filled 63 15 42 42 67 75 85 3.6 5 8 0.36 0.44 80 18 45 86 95 110 4.8 5 8 0.45 0.59 100 18.5 46.5 46.5 106 116 132 4.8 6 10 0.57 0.76 160 18 54 54 167 178 196 5.8 6 11 0.88 1.59 * Not available für NS 80 mm 56

Type 333 TE (front mounting flange, capillary outlet central back) Weight [kg] (approx.) NS b1 D D2 d1 d2 d3 s1 s3 unfilled filled 63 39 67 64 75 85 3.6 1 9 0.36 0.44 80 42 86 81 95 110 4.8 1 9 0.45 0.59 100 43 106 101 116 132 4.8 1 11.5 0.57 0.76 160 51 167 178 196 5.8 0.88 1.59 Type 334 KL (with U bracket, capillary outlet central back) Weight [kg] (approx.) NS b1 D D1 s4 unfilled filled 63 39 67 62 8 0.36 0.44 80 42 86 79 8 0.45 0.59 100 43 106 99 10 0.57 0.76 160 51 167 159 11 0.88 1.59 This information is provided as an example and relates to the version with connection type A or AK, Ø 10 mm, and immersion tube length 200 mm and capillary length 1 m. 57

Standard connection types Connections and immersion tube lengths Our precision dial thermometers are available with various connection options. The immersion tube lengths of SIKAspecific connections are based on the corresponding standardised protection tubes. Connection type A: Plain immersion tube, general purpose. Connection type AK: With adjustable compression fitting, for direct installation or use with protection tubes compliant with DIN 43772, Form 4, 5 and 6, or DIN 16179. Connection type Da: Union nut, for use with protection tubes compliant with DIN 43772, Form 8 or 9, or DIN 16179 CS. Connection type DN: Rotatable male thread with double threaded adapter, for use with protection tubes compliant with DIN 43772, Form 4, 5 and 6 or DIN 16179. Connection type SN*: Rotatable male thread, for use with protection tubes compliant with DIN 43772, Form 4, 5 and 6 or DIN 16179. Other connection types, immersion tubes lengths and immersion tube diameters are available on request. Connection type AK - G SW1 SW2 i Lk G½ B 27 22 14 42 G¾ B 32 22 16 42 ½ NPT 27 22 19 42 ¾ NPT 27 22 19 42 M20 x 1.5 27 22 14 42 Connection type Da - G SW i G½ B 27 10 G¾ B 32 12 M20 x 1.5 27 10 M27 x 2 32 12 Connection type A L ET Ød L Connection type AK l1 SW2 SW1 ET i Lk G Ød adjustable Connection type DN - G1 G2 SW1 SW2 i Lv G½ B G½ B 27 27 14 28 G¾ B G½ B 32 27 16 28 ½ NPT G½ B 27 27 19 28 ¾ NPT G½ B 27 27 19 28 M20 x 1.5 M20 x 1.5 27 27 14 28 M27 x 2 M20 x 1.5 32 27 16 28 Connection types Da l1 ET i SW G Connection type DN Based on connection type Da, with double threaded adapter SW2 G2 l1 Lv i G1 SW1 Ød ET Ød 58

Connection type SN* - G SW i G½ B 27 20 G¾ B 32 23 M20 x 1.5 27 20 M27 x 2 32 23 * * Not sealed; protection tube necessary. Connection type SN* i SW G ET L Ød Active length (ET) and minimum feasible immersion tube length The active length ET of a precision dial thermometer must be fully immersed in the medium to be measured. It depends on the scale range and the immersion tube diameter. The active length ET and the connection type determine the minimum immersion tube length necessary for engineering purposes. Connection type Length Thread Capillary length up to 5 m Immersion tube diameter Ød Capillary length >5 m up to 15 m Immersion tube diameter Ød Up to max 0...500 C Over 0...500 C Up to max 0...500 C Over 0...500 C 12 10 8 12 10 8 12 10 8 12 10 8 All types ET 35 45 75 75 105 165 53 80 115 150 200 320 A Lmin 55 65 95 95 125 185 73 100 135 170 220 340 AK l1min All standard threads 48 58 88 88 118 178 73 100 135 170 220 340 Da l1min All standard threads 55 65 95 95 125 185 73 100 135 170 220 340 DN l1min G½, M20 x 1.5 49 59 89 89 119 179 69 96 131 166 216 336 G¾, M27 x 2 51 61 91 91 121 181 72 99 134 169 219 339 ½ NPT, ¾ NPT 54 64 94 94 124 184 108 135 170 205 255 375 SN* Lmin All standard threads 55 65 95 95 125 185 73 100 135 170 220 340 The minimum length Lmin / l 1 min of the immersion tube is the shortest possible immersion tube length for a given active length ET (bulb) and connection type. The active length ET of the immersion tube (bulb) must be fully immersed in the substance to be measured in order to obtain measurements corresponding to the stated accuracy class. 59

Options Configure a thermometer suitable for your application here Order example Z 313 3 2 12 275583 5 C Thermometer type With wall bracket With rear mounting flange With front mounting flange With U bracket Nominal size 63 mm 80 mm 100 mm 160 mm Case material unfilled filled unfilled filled unfilled filled unfilled filled Stainless steel 1.4301 2 Scale range -40...40 C -40...60 C -30...50 C -20...60 C -20...80 C 0...80 C 0...100 C 0...120 C 0...160 C 0...200 C 0...250 C 0...300 C 0...400 C 0...500 C 0...600 C Connection type / immersion tube length Please see next page and insert here Capillary length Length in meter Capillary protection Without capillary protection (with spiral anti-kink sleeves at both ends ) With stainless steel spiral protection With plastic protection 313 323 333 334 1 A 2 B 3 C 4 D 44 46 35 26 28 08 10 12 16 20 25 30 40 50 60 xxxxxxx X B C D 60

Connection types / immersion tube length Connection types Connection type A, plain immersion tube Ø10 mm Length L [mm] Plain 108 06310B 145 10010B 205 16010B 295 25010B 445 40010B Connection type AK, adjustable compression fitting with immersion tube Ø10 mm Length l1 [mm] G½ G¾ M20 x 1.5 ½ NPT ¾ NPT 63 06392B 06393B 06397B 0639BB 0639CB 100 10092B 10093B 10097B 1009BB 1009CB 160 16092B 16093B 16097B 1609BB 1609CB 250 25092B 25093B 25097B 2509BB 2509CB 400 40092B 40093B 40097B 4009BB 4009CB Connection type Da, union nut with immersion tube Ø10 mm Length l1 [mm] G½ G¾ M20 x 1.5 M27 x 2 89* / 93** 08932B 09333B 08937B 09339B 126* / 130** 12632B 13033B 12637B 13039B 186* / 190** 18632B 19033B 18637B 19039B 276* / 280** 27632B 28033B 27637B 28039B 426* / 430** 42632B 43033B 42637B 43039B Connection type DN, rotatable male thread with double threaded adapter and immersion tube Ø10 mm Length l1 [mm] G½ G¾ M20 x 1.5 M27 x 2 ½ NPT ¾ NPT 63 06342B 06343B 06347B 0634BB 0634BB 0634CB 100 10042B 10043B 10047B 1004BB 1004BB 1004CB 160 16042B 16043B 16047B 1604BB 1604BB 1604CB 250 25042B 25043B 25047B 2504BB 2504BB 2504CB 400 40042B 40043B 40047B 4004BB 4004BB 4004CB Connection type SN, rotatable male thread with immersion tube Ø10 mm Length L [mm]*** G½ G¾ M20 x 1.5 M27 x 2 80 08062B 08063B 08067B 08069B 140 14062B 14063B 14067B 14069B 230 23062B 23063B 23067B 23069B 380 38062B 38062B 38067B 38069B * With G½ or M20 x 1.5 ** With G¾ or M27 x 2 *** Installation length L depends on thread On this page mentioned lengths are subject to technical feasibility; please observe the minimum immersion tube lengths in the two-page listing of standard connection types. 61

Remote reading diesel engine thermometers Type 311 WH, 321 TA, 331 KL and 332 TE Measuring system Nitrogen filled Type 321 TA Accuracy (EN 13190) Class 1 Case Crimped-on ring, stainless steel 1.4301 Case filling (silicone oil) Degree of protection (EN 60529) IP65 Nominal sizes 80, 100 mm Mechanical design Thermometer with capillary line Connection position: Bottom, central back Mounting flange: With wall bracket, rear mounting flange, front mounting flange, with U bracket Capillary Stainless steel Ø 2 mm, with spiral anti-kink sleeves at both ends Capillary length selectable from 1 m to 15 m Display ranges (EN 13190) 0...100 C, 0...120 C, 0...160 C, 0...250 C, 50...650 C Immersion tube Stainless steel 1.4571 Max. static working pressure: 25 bar Connection types: A, AK, Da Immersion tube diameter: 12 mm Immersion tube length: up to max. 400 mm Window Instrument glass Special versions Other immersion tube diameters and connection types on request Capillary > 15 m on request Other scale ranges and / or special scales, e.g. dual scale C / F, coloured zones or ranges, dial labelling, etc. Accessories Mechanical: see thermometer protection tubes section Pointer movement German silver / brass Zifferblatt Aluminium, white with black scale markings Aluminium, silver with black scale markings (for scale range 50...650 C) Pointer Aluminium, black Display correction (±6 %) Externally accessible screw 62

Dimensions and weights Type 311 WH (with wall bracket) Wall bracket Weight [kg] NS a b D D1 d7 s4 filled 80 15 42 86 79 26 8 0.60 100 15 43 106 99 26 10 0.78 * Details concerning wall brackets can be found in the chapter accessories. This information is provided as an example and relates to the version with connection type A, Ø 10 mm, and immersion tube length 200 mm and capillary 1 m. 63

Type 321 TA (rear mounting flange, capillary outlet bottom) Weight [kg] NS a1 b2 D d1 d2 d3 s s4 filled 80 18 45 86 95 110 4.8 5 8 0.60 100 18.5 46.5 106 116 132 4.8 6 10 0.78 This information is provided as an example and relates to the version with connection type A, Ø 10 mm, and immersion tube length 200 mm and capillary 1 m. 64

Type 332 TE (front mounting flange, capillary outlet central back) Weight [kg] NS b1 D D2 d1 d2 d3 s1 s3 filled 80 42 86 81 95 110 4.8 1 9 0.60 100 43 106 101 116 132 4.8 1 11.5 0.78 Type 331 KL (with U bracket, capillary outlet central back) Weight [kg] NG b1 D D1 s4 filled 80 42 86 79 8 0.60 100 43 106 99 10 0.78 This information is provided as an example and relates to the version with connection type A, Ø 10 mm, and immersion tube length 200 mm and capillary length 1 m. 65

Connection type A: Plain immersion tube, general purpose. Connection type AK: With adjustable compression fitting, for direct installation or use with protection tubes. Connection type A Connection type AK Connection type AK [mm] G SW1 SW2 i Lk G½ B 27 22 14 42 G¾ B 32 22 16 42 ½ NPT 27 22 19 42 ¾ NPT 27 22 19 42 M20 x 1.5 27 22 14 42 ET L ET i Standard connection types Connections and immersion tube lengths SW2 L L1 Lk G SW1 adjustable Ød Ød Other connection types, immersion tubes lengths and immersion tube diameters are available on request. The minimum length Lmin / l 1 min of the immersion tube is the shortest possible immersion tube length for a given active length ET (bulb) and connection type. The active length ET of the immersion tube (bulb) must be fully immersed in the substance to be measured in order to obtain measurements corresponding to the stated accuracy class. Active length (ET) and minimum feasible immersion tube length The active length ET of a precision dial thermometer must be fully immersed in the medium to be measured. It depends on the scale range and the immersion tube diameter. The active length ET and the connection type determine the minimum immersion tube length necessary for engineering purposes. Capillary length < 5 m Capillary length > 5 m Connection type Length Length ET Lmin ET Lmin A 80 150 120 175 AK 80 150 120 175 66

Options Configure a thermometer suitable for your application here Order example Z 311 B2 10 135 1 0 1 0 10 Type 311 WH 321 TA 331 KL 332 TE Nominal size 80 mm 100 mm Scale range 0...100 C 0...120 C 0...160 C 0...250 C 50...650 C Immersion tube length l 1 and L Immersion tube length l 1 135 mm 160 mm 200 mm 250 mm 300 mm 400 mm Connection type Immersion tube length L 180 mm 205 mm 245 mm 295 mm 345 mm 445 mm Connection type A, plain immersion tube Connection type AK, adjustable compression fitting Connection thread Without - plain immersion tube G½ G¾ ½ NPT ¾ NPT M20 x 1.5 Immersion tube diameter Ø 12 mm 2 Capillary length 1 m 2 m 5 m Length in meter Capillary material, protection Stainless steel, stainless steel spiral protection * Double scale C and F available on request. 311 321 331 332 B2 C2 10 12 16 25 56 135 160 200 250 300 400 1 9 0 2 3 B C 7 1 3 5 X C 67