Induction terminal units

Similar documents
series 90-GV Variable geometry units

KLIMA Active Chilled Beams

series KLR Linear slot diffusers

Total comfort control

series KFD-KLD Linear slot diffusers

series Linear grilles

Homepage > Products > Chilled Beams and Multi Service Chilled Beams > Active Chilled Beams > SMART BEAM > Type SMART BEAM SMART BEAM

Ceiling swirl diffusers with perforated face plate

Ceiling swirl diffusers

Ceiling induction diffuser DISA-300

Ceiling induction diffuser DISA-601

Type DCS FOR HORIZONTAL SWIRLING SUPPLY AIR DISCHARGE CREATING HIGH INDUCTION LEVELS, WITH FIXED AIR CONTROL BLADES

Slot diffusers, Round duct diffusers. IMP Klima

Ceiling diffusers. Type VDR. For large temperature differences in heating mode, high penetration of air, with adjustable air control blades

Ceiling swirl diffusers

C O L M A N. Air Distribution JET DIFFUSERS DCJ SERIES DCJ SERIES

Active Chilled Beams

Type VDL FOR HIGH ROOMS, WITH ADJUSTABLE AIR CONTROL BLADES. Homepage > Products > Air Diffusers > Swirl diffusers > Type VDL

C O L M A N. Air Distribution LINEAR SLOT DIFFUSERS CD SERIES SERIES

Ceiling swirl diffusers with perforated face plate

Active Chilled Beams

CornerAir. CornerAir. Active chilled beam

series PE-45 Polystyrene plenum boxes

Floor Swirls Models BZD and SZD

OptimAir NF. Active Chilled Beam OptimAir NF. Nov

SLOT DIFFUSERS, ROUND DUCT DIFFUSERS

Ceiling swirl diffusers

C O L M A N. Air Distribution PERFORATED FACE DIFFUSERS P SERIES SERIES

C O L M A N. Air Distribution LINEAR SLOT DIFFUSERS CE SERIES SERIES

C O L M A N. Air Distribution CIRCULAR DIFFUSERS LRS SERIES LRS SERIES

DRUM SLOT DIFFUSER TYPE: RT350

Round duct diffuser DBB-RR

HIGH CAPACITY LINEAR SLOT DUFFUSERS

Ceiling diffuser 4DE

Air diffuser system Model AUDIX -AW

LINEAR BAR GRILLES T SERIES. Quality and e!ciency without compromise

C O L M A N. Air Distribution SWIRL DIFFUSERS DWT SERIES DWT SERIES

Swirl Diffuser Model DQF

Slot diffusers for ceiling installation

Ventilation grilles for installation into walls, sills or rectangular

Swegon PACIFIC. Integrated climate beam

C O L M A N. Air Distribution LINEAR BAR GRILLES T SERIES SERIES

Ceiling diffuser 4DF

Air Distribution SWIRL DIFFUSERS DW SERIES SERIES

Linear Floor Grilles Models FG, F20, F25 and FRO

CCE - Adaptable active chilled beam for exposed installation. Halton CCE. Adaptable active chilled beam for exposed installation

Systempac. Fan Coil Unit / Acoustic Flex / Diffuser System Package. Systempac. January Features and Design Guide

Swegon PACIFIC. Integrated climate beam

Ventilation grilles for installation into walls, sills or rectangular

Swegon PACIFIC. Integrated climate beam QUICK FACTS KEY FIGURES

Swirl Diffuser DHV Contents Description...3 Models and dimensions...4 Technical data...8

Ceiling impulse diffuser Model PIL

Halton Rex 600 RE6 - Adaptable active chilled beam

Ventilation grilles for installation into walls, sills or rectangular

Ventilation grilles for installation into walls, sills or rectangular

DFB - Conical Ceiling Diffuser. Halton DFB. Conical Ceiling Diffuser

Optima EXHAUST GRILL AND AIR LOUVER. Perforated Ceiling Diffusers. Features: Standard square sizes:

Air Displacement Vent Units

Redefine your comfort zone. chilled beams. energy solutions

series Silencers

Ceiling Slot Diffuser DSC

ceiling swirl diffuser Model DQJA / DQJR

ceiling swirl diffuser DQJ

Ceiling Slot Diffuser Model DSX

LINEAR SLOT DIFFUSERS

Disc valves. Type Z-LVS. For supply air. 03/2017 DE/en PD Z-LVS 1

Ventiduct nozzle ducts

Linear Slot Diffusers Model Slot 20 and Model Slot 25

Ceiling Slot Diffuser DSC

PRODUCT BROCHURE. Rectangular Displacement Diffuser RDW-FD RDW-FD : smartemp.com

2/18/EN/2. Air Handling Lights. Type LR. Recommended for use in rooms with ceiling heights of approx m

COMFORT AIR CURTAIN. SensAir

CHILLED BEAM IQ STAR WEGA II

Ventiduct nozzle ducts

DSC-PLASTER Slot diffuser for plasterboard ceilings

PURELINE18 PARTICULARLY SLIM DIFFUSER FACE, AVAILABLE IN NUMEROUS VARIANTS FOR MANY DIFFERENT INSTALLATION SITUATIONS

Type VSD35. Nominal length up to 1500 mm: one spigot

SDV Vane Swirl Diffusers

Displacement flow diffusers. L e

Use. Installation. Key figures. Worth noting. linx industries chilled beams

Adriatic for individually suspended installation Exposed active climate beam with cooling, heating and ventilation

DKS - Multi-nozzle Ceiling Diffuser. Halton DKS. Multi-nozzle Ceiling Diffuser

C O L M A N. Air Distribution NOZZLE DIFFUSERS N SERIES SERIES

THB - Perforated Ceiling Diffuser. Halton THB. Perforated Ceiling Diffuser

Incorporating V2.1. Product spec >>> > Series ECG - Egg crate grilles

LINEAR SLOT DIFFUSERS

Round duct grille Model KG-RR

Ceiling Swirl Diffuser DQJ

Compact Grille Model KG

Adjustable Curved Vane Diffusers. Vanes are parallel to the width dimension Vanes are parallel to the height dimension

Ceiling Slot Diffuser DSC

CBQ Multiservice chilled beam platform for suspended installation

Catalog Swirl diffuser DAL 359

WGA Long throw nozzle grille

WALL VENTILATION GRILLES CBP

Wall and Ceiling Grille

DKR - Multi-nozzle Ceiling Diffuser. Halton DKR. Multi-nozzle Ceiling Diffuser

Type ISH FOR INDUSTRIAL ZONES WITHOUT AIR POLLUTING PROCESSES

MANUAL INSTALLATION. Active Chilled Beam Linear. ACBL Series. v101 Issue Date: 04/10/ Price Industries Limited. All rights reserved.

Linear Slot Diffusers Model Slot 20 & Model Slot 25

Transcription:

series IHK

Series IHK 1 Induction terminal units IHK IHK-F IHK-V CONTENTS age eneral Features 2 Dimensions and Configurations 4 Induction terminal unit IHK-F 5 Induction terminal unit IHK-V 6 Installation 8 Technical Data 10 Selection Charts 15 roduct Codes 16

2 Series IHK eneral Features Description The IHK ceiling-mounted induction terminal units are used in air-water systems to provide a high level of comfort in interior environments with high internal thermal loads in cooling operation. The IHK units are recommended for bulkhead and suspended ceiling installation. Ideal for hotel guest rooms and hospitals. The units include the following components:.rimary air plenum, with one round duct connections for priihk mary air inlet and a distribution of small nozzles with alternative settings. Hot or chilled water (two-pipe installation) or hot and chilled water (four-pipe installation) coil. rille, for supply and diffusion of the combined primary and induced air to the room. Return grille, used also as access for unit cleaning. Available in different perforation designs.... As primary air exits the nozzles, this induces air from the room (which we will call secondary), that flows through the coil, cooling and/or heating, as applicable, and is mixed with the primary air inside the unit before it is supplied to the room through the grille. IHK hinged perforated return grille As in all air-water air conditioning systems, choosing an induction terminal unit has the advantage of using water as a vehicle to carry the cooling or heating power to the rooms, which saves on energy and space compared to all-air A/C systems. In addition, the temperature of each room or independent area can be controlled by adding a 2- or 3-way valve to the terminal unit controlled by the respective room control. aterials The outer and inner housings, nozzle plate are of galvanised steel sheet construction and have a standard powder-paint finish of RAL 9010. Other RAL colours are available upon request. lastic nozzles assembled in sheet metal plate. Supply and return grilles are available in aluminium or steel material. The coil is manufactured of copper pipes and aluminium fins. Detailed view of operating principle

Series IHK 3 eneral Features Advantages The IHK ceiling-mounted induction units are terminal units for central air conditioning installations that provide solutions to meet the needs of the following:.ventilation achieved with primary air.cooling, based on the primary air itself and the water circulation coil.heating, based on a water circulation coil.control. ossibility of individual or combined unit control by room or area, using control and regulation valves in the unit to adjust the water volume and room thermostats.air diffusion based on a grille that ensure effective air diffusion. In addition to the functional advantages described, the IHK units have the following main advantages over conventional HVAC systems (fan coils, VRV, all air, etc.):.high energy efficiency and low life-cycle or operating costs; this advantage is mainly due to the absence of a fan in the terminal unit.lowest maintenance costs; the unit contains no filter or condensate pan to replace or clean and only cleaning of the coil surface is needed (recommended every 2 years).low noise level.no draughts in occupied area.extremely hygienic systems, since no filters, condensation tray and drainage tubing are used..space-saving: smaller air ductwork and equipment units.easy to mount.adaptation to the installation conditions. 1- Supply air grille 2- Return air grille 3 - Supply air connection 4 - Water pipe connections (2 pipes)

4 Series IHK Dimensions. Configurations LATERAL ENTRY Sizes 900 to 1500-4-pipe system (2-pipe system connections also available) Four types of configurations are available, defined according to the position of the primary air and water connections: 1. Lateral primary air connection and water on left side, (-LIWI) type 2. Lateral primary air connection on left side and water on rigth side, (-LIWD) type 3. Lateral primary air connection and water on rigth side, (-LDWD) type 4. Lateral primary air connection on rigth side and water on left side, (-LDWI) type ODEL A B C 900 932 828 900 1200 1232 1128 1200 1500 1532 1428 1500

Series IHK 5 Dimensions. Configurations FRONT ENTRY Sizes 900 to 1500-4-pipe system (2-pipe system connections also available) Two types of configurations are available, defined according to the position of the primary air and water connections: 1. Front face primary air connection and water on left side, (-FWI) type 2. Front face primary air connection and water on rigth side, (-FWD) type ODEL A B C 900 932 828 900 1200 1232 1128 1200 1500 1532 1428 1500

6 Series IHK IHK-F The IHK-F ceiling-mounted induction terminal unit from Koolair are specifically designed for use in hotels and hospitals, where the area to be cooled has not suspended ceiling and therefore their installation is in the hall annex. The one-way horizontal supply air and the return is made in the same grille. ODEL A B 900 932 900 1200 1232 1200 1500 1532 1500 The cooling and heating powert are 8% lower than the IHK model whose values found in pages from 11 to 14.

Series IHK 7 IHK-V The IHK-V induction terminal unit from Koolair are specifically designed for installation along the perimeter zones. The unit is installed against the facade, it is not required space on the floor, ceiling or corridor. This model is available with condensation tray. ODEL A 900 900 1200 1200 1500 1500 The cooling and heating powert are equals the IHK model whose values found in pages from 11 to 14.

8 Series IHK Installation The IHK units include a series of hanging brackets on the two upper longitudinal sides of the units, as shown in the following photographs. There are two brackets per side. These brackets have a slot hole to hold a Ø6 mm threaded rod, which is first attached to the ceiling slab to hang the unit. The unit can be fixed directly to the ceiling surface or suspended using threaded drop rods. ODEL A B 900 802 932 1200 1102 1232 1500 1402 1532

Series IHK 9 Volume Regulation and Control Components - Air Control Usually, the constant flow system is used most often to distribute primary air to the induction terminal units. To ensure that the installation is correctly balanced, an extremely important aspect for proper operation of the active chilled beam, Koolair RCCK mechanical self-regulators are used because they ensure self-balancing of the installation. CRC- manual volume control dampers can be selected but require manual balancing of the installation. echanical constant air flow self-regulator, KCR model Ductwork pressure dampers (RVV) can be used to ensure the specific inlet pressure in each beam. If a variable air flow system based on occupancy, for example, is designed, then the minimum design flow rate per unit should correspond to a minimum inlet pressure of approximately 40 a to the beam. Constant air volume regulator, RCCK model

10 Series IHK Technical Data Symbols The symbols used in the selection tables for the IHK are the following: Q pr rimary air flow L w -db(a) Sound power level, in db(a) D pr rimary air pressure drop, in a T pr rimary air temperature, in o C T R Room air temperature o C DT pr Temperature difference between room air and primary air (T R - T pr ) Q W Water flow rate, in L/h Δ W Water pressure drop in the coil, in ka T WIN Water inlet temperature in the coil, in o C ΔT W Water temperature difference in the coil ΔT SWIN Temperature difference between room and unit water inlet pr Capacity supplied by primary air, in W SW Capacity supplied by the coil, in W T Total capacity pr + SW in W X Throw of the air jet, in m, for a maximum velocity in the occupied area of 0.25 m/s with ΔT = 0 o C (supply - room)

Series IHK 11 Technical Data. Selection Tables COOLIN - 2-IE SYSTE Reference water flow (Q W ) of 200 L/h For other water flow rates, correct the unit capacity ( SW ) in the table by the factors listed in the attached table. IHK -2-IE SYSTE COOLIN SIZE 900 1200 1500 Q W (l/h) Capacity coil correction factor 80 0,79 0,79 0,79 100 0,85 0,84 0,85 120 0,89 0,88 0,89 150 0,95 0,94 0,95 180 0,98 0,98 0,98 200 1,00 1,00 1,00 250 1,03 1,03 1,03 290 1,05 1,05 1,05 340 1,07 1,07 1,07 SIZE 900 1200 1500 TYE NOZZLE IHK - 2-IE SYSTE - COOLIN DT pr (K) DT SWIN (K) Q r L W - D 6 7 8 9 10 6 7 8 9 10 12 pr l/s m 3 /h db(a) (a) X (m) pr (W) SW (W) 6,9 25 <20 53 2,2 50 58 66 75 83 172 201 223 258 284 341 9,2 33 23 92 2,8 66 77 88 99 110 212 244 277 315 349 418 11,1 40 28 136 3,5 80 93 106 120 133 245 281 321 362 403 483 12,5 45 31 172 3,9 90 105 120 135 150 267 307 352 395 440 528 13,9 50 34 212 4,3 100 116 133 150 166 288 332 381 427 476 571 12,5 45 <20 55 3,1 90 105 120 135 150 223 257 292 331 367 440 16,1 58 24 92 4,1 116 135 154 174 193 270 310 355 399 444 533 19,4 70 30 134 4,9 140 163 186 210 233 308 356 409 457 510 612 22,2 80 33 176 5,6 160 186 213 240 266 338 393 450 503 561 673 25,0 90 36 223 6,3 180 210 240 270 300 364 426 488 545 607 729 19,4 70 20 54 3,6 140 163 186 210 233 252 290 332 373 415 498 25,0 90 27 90 4,7 180 210 240 270 300 303 349 401 449 500 600 30,6 110 33 135 5,7 220 256 293 330 366 347 404 463 517 577 692 34,7 125 36 175 6,5 250 291 333 375 416 376 441 504 564 628 754 38,9 140 39 219 7,3 280 326 373 420 466 402 473 540 605 672 808 9,2 33 <20 50 2,4 66 77 88 99 110 223 258 299 335 377 453 12,5 45 25 93 3,3 90 105 120 135 150 283 330 379 425 476 571 15,0 54 30 134 3,0 108 126 144 162 180 325 379 434 486 543 651 17,5 63 34 182 4,6 126 147 168 189 210 363 424 484 543 606 726 20,8 75 39 258 5,5 150 175 200 225 250 409 478 545 612 682 816 16,1 58 <20 50 3,5 116 135 154 174 193 286 333 383 429 480 576 20,6 74 25 81 4,4 148 172 197 222 246 343 400 457 513 573 686 25,6 92 31 126 5,5 184 214 245 276 306 399 466 532 597 665 797 30,0 108 35 173 6,4 216 252 288 324 360 444 519 590 663 739 884 36,1 130 40 251 7,7 260 303 346 390 433 497 582 661 744 828 991 25,0 90 22 49 3,0 180 210 240 270 300 323 377 431 483 540 648 30,6 110 27 73 4,9 220 256 293 330 366 373 436 497 557 622 745 40,3 145 35 127 6,4 290 338 386 435 483 448 524 596 671 747 894 47,2 170 39 175 7,5 340 396 453 510 566 495 579 657 740 823 985 52,8 190 42 218 8,4 380 443 506 570 633 528 618 701 790 878 1052 11,7 42 <20 53 2,7 84 98 112 126 140 285 328 376 422 471 566 14,4 52 24 81 3,4 104 121 138 156 173 333 385 442 495 553 663 17,5 63 30 119 4,1 126 147 168 189 210 383 443 508 569 635 762 21,1 76 35 173 4,0 152 177 202 228 253 436 506 580 649 724 869 25,0 90 40 244 5,9 180 210 240 270 300 488 567 649 728 811 971 19,4 70 20 47 3,7 140 163 186 210 233 347 401 460 516 576 691 25,0 90 27 79 4,8 180 210 240 270 300 415 481 551 618 689 827 30,6 110 32 118 5,8 220 256 293 330 366 475 552 632 708 790 946 36,1 130 37 164 6,9 260 303 346 390 433 529 616 703 789 878 1052 41,7 150 41 219 7,9 300 350 400 450 500 577 672 767 861 957 1146 31,9 115 23 52 4,5 230 268 306 345 383 406 470 539 604 674 808 40,3 145 29 83 5,7 290 338 386 435 483 475 552 631 708 789 945 49,4 178 35 125 7,0 356 415 474 534 593 541 630 719 807 898 1076 58,3 210 40 175 8,3 420 490 560 630 700 597 696 794 891 990 1185 69,4 250 44 248 9,8 500 583 666 750 833 656 766 875 983 1089 1305 D W (ka) 5.5 7,0 8.5

12 Series IHK Technical Data. Selection Tables COOLIN - 4-IE SYSTE Reference water flow (Q W ) of 200 L/h For other water flow rates, correct the unit capacity ( SW ) in the table by the factors listed in the attached table. IHK - 4-IE SYSTE COOLIN SIZE 900 1200 1500 Q W (l/h) Capacity coil correction factor 80 0,79 0,79 0,79 100 0,85 0,84 0,85 120 0,89 0,88 0,89 150 0,95 0,94 0,95 180 0,98 0,98 0,98 200 1,00 1,00 1,00 250 1,03 1,03 1,03 290 1,05 1,05 1,05 340 1,07 1,07 1,07 SIZE 900 1200 1500 TYE NOZZLE IHK - 4-IE SYSTE - COOLIN DT pr (K) DT SWIN (K) Q r L W - D 6 7 8 9 10 6 7 8 9 10 12 pr l/s m 3 /h db(a) (a) X (m) pr (W) SW (W) 6,9 25 <20 53 2,2 50 58 66 75 83 136 167 201 235 276 346 9,2 33 23 92 2,8 66 77 88 99 110 180 217 253 288 327 401 11,1 40 28 136 3,5 80 93 106 120 133 214 256 294 331 370 448 12,5 45 31 172 3,9 90 105 120 135 150 236 281 321 360 400 481 13,9 50 34 212 4,3 100 116 133 150 166 257 304 346 387 429 514 12,5 45 <20 55 3,1 90 105 120 135 150 198 238 275 311 350 426 16,1 58 24 92 4,1 116 135 154 174 193 246 291 332 372 413 496 19,4 70 30 134 4,9 140 163 186 210 233 284 334 378 423 467 558 22,2 80 33 176 5,6 160 186 213 240 266 312 364 412 462 510 609 25,0 90 36 223 6,3 180 210 240 270 300 337 392 443 498 550 657 19,4 70 20 54 3,6 140 163 186 210 233 229 272 311 350 389 469 25,0 90 27 90 4,7 180 210 240 270 300 279 328 371 416 459 549 30,6 110 33 135 5,7 220 256 293 330 366 321 374 422 475 524 625 34,7 125 36 175 6,5 250 291 333 375 416 348 404 456 514 568 679 38,9 140 39 219 7,3 280 326 373 420 466 373 431 488 551 610 729 9,2 33 <20 50 2,4 66 77 88 99 110 209 247 272 307 332 382 12,5 45 25 93 3,3 90 105 120 135 150 261 308 344 387 428 504 15,0 54 30 134 3,0 108 126 144 162 180 297 350 395 442 493 585 17,5 63 34 182 4,6 126 147 168 189 210 330 389 441 493 550 658 20,8 75 39 258 5,5 150 175 200 225 250 370 436 498 555 618 743 16,1 58 <20 50 3,5 116 135 154 174 193 263 311 348 391 433 510 20,6 74 25 81 4,4 148 172 197 222 246 312 368 416 466 520 620 25,6 92 31 126 5,5 184 214 245 276 306 362 426 485 542 604 724 30,0 108 35 173 6,4 216 252 288 324 360 401 471 540 602 668 804 36,1 130 40 251 7,7 260 303 346 390 433 450 526 606 675 743 896 25,0 90 22 49 3,0 180 210 240 270 300 295 348 392 439 490 582 30,6 110 27 73 4,9 220 256 293 330 366 338 399 453 506 565 676 40,3 145 35 127 6,4 290 338 386 435 483 406 476 546 609 674 812 47,2 170 39 175 7,5 340 396 453 510 566 447 523 603 672 740 892 52,8 190 42 218 8,4 380 443 506 570 633 478 558 642 716 786 948 11,7 42 <20 53 2,7 84 98 112 126 140 254 299 338 391 445 546 14,4 52 24 81 3,4 104 121 138 156 173 302 354 400 455 512 621 17,5 63 30 119 4,1 126 147 168 189 210 350 408 462 520 581 699 21,1 76 35 173 4,0 152 177 202 228 253 400 466 527 590 657 786 25,0 90 40 244 5,9 180 210 240 270 300 447 520 589 659 731 873 19,4 70 20 47 3,7 140 163 186 210 233 316 369 417 473 532 642 25,0 90 27 79 4,8 180 210 240 270 300 381 443 501 562 627 751 30,6 110 32 118 5,8 220 256 293 330 366 436 507 574 642 713 851 36,1 130 37 164 6,9 260 303 346 390 433 483 561 637 712 790 944 41,7 150 41 219 7,9 300 350 400 450 500 524 609 693 776 860 1028 31,9 115 23 52 4,5 230 268 306 345 383 372 433 490 550 614 736 40,3 145 29 83 5,7 290 338 386 435 483 435 506 574 641 712 851 49,4 178 35 125 7,0 356 415 474 534 593 493 573 651 728 807 965 58,3 210 40 175 8,3 420 490 560 630 700 540 628 716 802 889 1065 69,4 250 44 248 9,8 500 583 666 750 833 591 688 785 883 980 1176 D W (ka) 4.1 5,3 6.4

Series IHK 13 Technical Data. Selection Tables HEATIN - 2 -IE SYSTE Reference water flow (Q W ) of 200 L/h For other water flow rates, correct the coil capacity ( SW ) in the table by the factors listed in the attached table. IHK - 2-IE SYSTE HEATIN SIZE 900 1200 1500 Q W (l/h) Capacity coil correction factor 80 0,81 0,81 0,81 100 0,86 0,86 0,86 120 0,89 0,89 0,89 150 0,96 0,96 0,96 180 0,98 0,98 0,98 200 1,00 1,00 1,00 250 1,03 1,03 1,03 290 1,04 1,04 1,04 340 1,06 1,06 1,06 SIZE 900 1200 1500 TYE NOZZLE IHK - 2-IE SYSTE - HEATIN DT pr (K) DT SWIN (K) Q r L W - D 6 7 8 9 10 10 15 20 25 30 35 pr l/s m 3 /h db(a) (a) X (m) pr (W) SW (W) 6,9 25 <20 53 2,2 50 58 66 75 83 223 337 451 566 680 792 9,2 33 23 92 2,8 66 77 88 99 110 279 421 564 708 850 993 11,1 40 28 136 3,5 80 93 106 120 133 325 491 657 825 991 1158 12,5 45 31 172 3,9 90 105 120 135 150 357 539 721 905 1087 1271 13,9 50 34 212 4,3 100 116 133 150 166 387 584 782 981 1179 1379 12,5 45 <20 55 3,1 90 105 120 135 150 282 425 569 714 858 1002 16,1 58 24 92 4,1 116 135 154 174 193 345 520 696 874 1050 1227 19,4 70 30 134 4,9 140 163 186 210 233 399 602 805 1010 1214 1420 22,2 80 33 176 5,6 160 186 213 240 266 441 665 890 1117 1343 1571 25,0 90 36 223 6,3 180 210 240 270 300 481 725 971 1218 1464 1713 19,4 70 20 54 3,6 140 163 186 210 233 300 453 606 761 914 1068 25,0 90 27 90 4,7 180 210 240 270 300 366 552 739 927 1114 1303 30,6 110 33 135 5,7 220 256 293 330 366 427 644 861 1081 1299 1519 34,7 125 36 175 6,5 250 291 333 375 416 469 707 947 1188 1428 1671 38,9 140 39 219 7,3 280 326 373 420 466 510 768 1027 1289 1550 1813 9,2 33 <20 50 2,4 66 77 88 99 110 298 447 595 744 897 1047 12,5 45 25 93 3,3 90 105 120 135 150 379 570 760 952 1146 1341 15,0 54 30 134 3,0 108 126 144 162 180 437 657 877 1098 1321 1548 17,5 63 34 182 4,6 126 147 168 189 210 492 739 987 1237 1487 1742 20,8 75 39 258 5,5 150 175 200 225 250 561 842 1125 1410 1695 1984 16,1 58 <20 50 3,5 116 135 154 174 193 366 551 734 919 1106 1295 20,6 74 25 81 4,4 148 172 197 222 246 443 666 888 1113 1338 1568 25,6 92 31 126 5,5 184 214 245 276 306 523 785 1049 1314 1580 1851 30,0 108 35 173 6,4 216 252 288 324 360 589 884 1181 1480 1779 2082 36,1 130 40 251 7,7 260 303 346 390 433 672 1007 1347 1687 2029 2373 25,0 90 22 49 3,0 180 210 240 270 300 389 584 780 976 1175 1376 30,6 110 27 73 4,9 220 256 293 330 366 454 683 912 1142 1373 1609 40,3 145 35 127 6,4 290 338 386 435 483 560 841 1123 1407 1692 1981 47,2 170 39 175 7,5 340 396 453 510 566 628 943 1260 1579 1899 2222 52,8 190 42 218 8,4 380 443 506 570 633 679 1019 1362 1707 2052 2400 11,7 42 <20 53 2,7 84 98 112 126 140 373 566 751 936 1127 1319 14,4 52 24 81 3,4 104 121 138 156 173 443 668 889 1110 1335 1562 17,5 63 30 119 4,1 126 147 168 189 210 515 774 1032 1290 1551 1814 21,1 76 35 173 4,0 152 177 202 228 253 594 891 1190 1489 1790 2092 25,0 90 40 244 5,9 180 210 240 270 300 673 1008 1347 1687 2027 2369 19,4 70 20 47 3,7 140 163 186 210 233 442 667 888 1109 1334 1561 25,0 90 27 79 4,8 180 210 240 270 300 538 808 1079 1350 1622 1897 30,6 110 32 118 5,8 220 256 293 330 366 626 939 1254 1570 1887 2206 36,1 130 37 164 6,9 260 303 346 390 433 707 1059 1415 1773 2130 2490 41,7 150 41 219 7,9 300 350 400 450 500 780 1169 1563 1958 2353 2750 31,9 115 23 52 4,5 230 268 306 345 383 491 739 985 1232 1481 1732 40,3 145 29 83 5,7 290 338 386 435 483 587 881 1176 1472 1769 2068 49,4 178 35 125 7,0 356 415 474 534 593 683 1023 1367 1712 2057 2405 58,3 210 40 175 8,3 420 490 560 630 700 766 1148 1535 1923 2311 2701 69,4 250 44 248 9,8 500 583 666 750 833 860 1290 1724 2159 2595 3033 D W (ka) 5.5 7,0 8.5

14 Series IHK Technical Data. Selection Tables HEATIN - 4 -IE SYSTE Reference water flow (Q W ) of 200 L/h For other water flow rates, correct the coil capacity ( SW ) in the table by the factors listed in the attached table. IHK - 4-IE SYSTE HEATIN SIZE 900 1200 1500 Q W (l/h) Capacity coil correction factor 30 0,65 0,65 0,65 50 0,78 0,78 0,78 70 0,85 0,85 0,85 90 0,90 0,90 0,90 110 0,93 0,93 0,93 130 0,95 0,95 0,95 150 0,97 0,97 0,97 180 0,99 0,99 0,99 200 1,00 1,00 1,00 250 1,02 1,02 1,02 SIZE 900 1200 1500 TYE NOZZLE IHK - 4-IE SYSTE - HEATIN DT pr (K) DT SWIN (K) Q r L W - D 6 7 8 9 10 10 15 20 25 30 35 pr l/s m 3 /h db(a) (a) X (m) pr (W) SW (W) 6,9 25 <20 53 2,2 50 58 66 75 83 146 224 298 375 452 529 9,2 33 23 92 2,8 66 77 88 99 110 171 263 346 433 520 610 11,1 40 28 136 3,5 80 93 106 120 133 190 290 381 476 571 671 12,5 45 31 172 3,9 90 105 120 135 150 201 306 402 504 604 711 13,9 50 34 212 4,3 100 116 133 150 166 211 320 421 529 635 746 12,5 45 <20 55 3,1 90 105 120 135 150 178 273 359 448 538 632 16,1 58 24 24 4,1 116 135 154 174 193 202 308 405 507 609 716 19,4 70 30 134 4,9 140 163 186 210 233 219 333 439 552 663 779 22,2 80 33 176 5,6 160 186 213 240 266 230 348 461 461 701 824 25,0 90 36 223 6,3 180 210 240 270 300 239 361 481 609 734 864 19,4 70 20 54 3,6 140 163 186 210 233 190 291 382 478 573 673 25,0 90 27 90 4,7 180 210 240 270 300 214 325 427 537 644 758 30,6 110 33 135 5,7 220 256 293 330 366 231 349 462 583 702 825 34,7 125 36 175 6,5 250 291 333 375 416 240 362 483 612 738 868 38,9 140 39 219 7,3 280 326 373 420 466 248 374 501 637 769 906 9,2 33 <20 50 2,4 66 77 88 99 110 181 276 374 473 569 662 12,5 45 25 93 3,3 90 105 120 135 150 210 320 435 550 659 769 15,0 54 30 134 3,0 108 126 144 162 180 229 349 473 599 716 837 17,5 63 34 182 4,6 126 147 168 189 210 246 373 506 640 765 896 20,8 75 39 258 5,5 150 175 200 225 250 266 400 543 685 820 963 16,1 58 <20 50 3,5 116 135 154 174 193 211 323 438 438 663 774 20,6 74 25 81 4,4 148 172 197 222 246 237 361 490 619 740 866 25,6 92 31 126 5,5 184 214 245 276 306 262 395 536 677 809 950 30,0 108 35 173 6,4 216 252 288 324 360 280 420 568 717 858 1010 36,1 130 40 251 7,7 260 303 346 390 433 299 446 603 760 912 1074 25,0 90 22 22 3,0 180 210 240 270 300 225 342 464 587 702 820 30,6 110 27 73 4,9 220 256 293 330 366 247 374 507 641 766 897 40,3 145 35 127 6,4 290 338 386 435 483 277 416 564 712 852 1002 47,2 170 39 175 7,5 340 396 453 510 566 294 440 594 749 899 1059 52,8 190 42 218 8,4 380 443 506 570 633 306 455 614 774 930 1095 11,7 42 <20 53 2,7 84 98 112 126 140 218 328 446 564 676 792 14,4 52 24 81 3,4 104 121 138 156 173 239 361 493 623 748 877 17,5 63 30 119 4,1 126 147 168 189 210 260 393 537 393 815 956 21,1 76 35 173 4,0 152 177 202 228 253 281 424 579 732 879 1032 25,0 90 40 244 5,9 180 210 240 270 300 300 452 615 778 934 1097 19,4 70 20 47 3,7 140 163 186 210 233 245 371 506 640 768 901 25,0 90 27 79 4,8 180 210 240 270 300 273 413 563 713 855 1004 30,6 110 32 118 5,8 220 256 293 330 366 296 446 607 768 922 1083 36,1 130 37 164 6,9 260 303 346 390 433 314 472 640 809 972 1142 41,7 150 41 219 7,9 300 350 400 450 500 328 493 666 840 1008 1186 31,9 115 23 52 4,5 230 268 306 345 383 265 401 547 693 831 975 40,3 145 29 83 5,7 290 338 386 435 483 292 440 599 757 909 1068 49,4 178 35 125 7,0 356 415 474 534 593 314 472 640 809 971 1141 58,3 210 40 175 8,3 420 490 560 630 700 330 495 669 844 1013 1192 69,4 250 44 248 9,8 500 583 666 750 833 345 518 696 877 1051 1236 D W (ka) 5.5 7,0 8.5

Series IHK 15 Technical Data ressure drop in water The charts to obtain the pressure drop in the coil for different water flow rates in the various systems are shown below: 2-pipe system. Cooling - Heating Q W (l/h) Length (mm) 4-pipe system. Cooling Q W (l/h) 4-pipe system. Heating Length (mm) Q W (l/h) Length (mm)

16 Series IHK roduct Codes Coding example of an order. All of the different models, sizes, accessories, etc., existing in the KOOLAIR IHK series are listed. (a): odel IHK standard induction terminal unit IHK-F induction terminal unit, supply and return in the same grille IHK-V perimetral induction terminal unit (b): Length IHK : 900 1200 1500 (mm) (c): Nozzle configuration - - - (d): Coil Type of system. - 2 2-pipe system coil - 4 4-pipe system coil (e): Air/water connection configuration - FWI Front face primary air connection and water connection on left - FWD Front face primary air connection and water connection on rigth - LIWI Lateral primary air and water connections on left - LIWD Lateral primary air connection on left and water connection on rigth - LDWD Lateral primary air and water connections on rigth - LDWI Lateral primary air connection on rigth and water connection on left (f): Type of supply grille - 20-DH Double deflection grille - 31-1 Linear grille with horizontal fixed blades (g): Type of return grille - 22-5 Egg crate grille - 27-R erforate plate grille (h): Finish - RAL 9010 Standard finish in RAL 9010 - RAL Finish in RAL paint upon request

Series IHK 17 (i): Other accessories or components By special request on the order, other components can be requested, e.g.: - Electric resistor: For 2-pipe systems (chilled water), included inside the unit. Specify the power in watts (W) provided by it. - Control valve: Control and/or balancing valves can be included in the water connections by special order. Specify the model and type, as well as the respective servo drive if applicable. - Condensation detector: The unit can be fitted with a condensation detector attached to the surface of the chilled water inlet pipe by special order. - Coding example (a) (b) (c) (d) (e) (f) (g) (h) (i) IHK 1200 2 LIWI 20-DH 22-5 RAL 9010 others Technical specifications Active chilled beams with one way air discharge, Koolair s type IHK, length C mm, heigth 200 mm, suitable to be installed with horizontal position in false ceilings or plaster board bulkhead, for hotel bedrooms, individual hospital wards and cellular offices. It can be equipped with many options of induced and supply air grille design. Consisting of a casing with suspension holes, connecting spigot Ø125 mm (frontal or lateral), with plastic nozzles assembled in sheet metal plate, in three sizes (--) to optimise induction. Batteries can be 2 or 4 pipes system, made of copper tubes, formed aluminium fins and provide water-side connecting tails external threaded 1/2. Units are manufactured combined galvanised sheet steel and aluminium grilles finished Ral 9010, others colours are available under request.

18 Series IHK THIS CATALOUE IS COYRIHTED. artial or full reproduction of its content is strictly prohibited without express written authorisation from KOOLAIR, S.A. CIN-IHK-1012-00

Koolair S.A. olígono Industrial 2 La Fuensanta 28936 óstoles (adrid) Tel 91 645 00 33 Fax 91645 69 62 www.koolair.com