CO95. Carbon Monoxide Detector INSTRUCTION MANUAL ENGLISH Fax: (503)

Similar documents
KANEAUTO 4-4 & KANE AUTO 5-4

Cable Length Meter INSTRUCTION MANUAL

DAFM4. Digital Air Flow Meter INSTRUCTION MANUAL Fax: (503) ENGLISH DAFM4 VOL CFM

INSTRUCTION MANUAL DM5B Fax: (503)

DT304. Digital Temperature Logger INSTRUCTION MANUAL

INSTRUCTION MANUAL M110A Fax: (503)

Test Equipment Depot Washington Street Melrose, MA TestEquipmentDepot.com INSTRUCTION MANUAL PSMR1

INSTRUCTION MANUAL PET Fax: (503)

Flue Gas Analyzer IMR 1100F

DMG200. Digital Micron Gauge. 99 Washington Street Melrose, MA Phone Toll Free

KANE425. Flue Gas Analyser. Kane International Ltd Kane House, Swallowfield Welwyn Garden City Hertfordshire, AL7 1JG

DMG100 Digital Micron Gauge Limited Warranty DMG100 DMG100 Digital Micron Gauge USA CANADA COPYRIGHT 2011 UEi

SENSIT TKX INSTRUCTION MANUAL. Combustible Gas Leak Detector. Read and understand instructions before use.

CM100. Carbon Monoxide Meter. 99 Washington Street Melrose, MA Phone Toll Free

Megohmmeter Test Probe

INTRODUCTION. Backlight for operating in dark area Low battery indicator Auto power off function. CO levels and its effect

IAQ-CALC INDOOR AIR QUALITY METER MODEL 7515

IAQ-CALC TM Indoor Air Quality Meter

Infrared Thermocouple Probe

Universal 8-Bay Charger. for AA/AAA/C/D/9 NiMH & NiCd Rechargeable Batteries. Owner's Manual

Thermometer models / 00831A

SL101 Manual_SL101 User Manual 05/10/ :06 Page 1. Instruction Manual

Operator s Manual TC-253A. Temperature Converter

INSTRUCTION MANUAL CM95/ CM100 TRUE RMS FLEXIBLE CLAMP METER. 1. SAFETY INFORMATION: Always read before proceeding. REMEMBER: SAFETY IS NO ACCIDENT

1.Safe testing IMPORTANT:

Wireless Thermometer model 00380

362 Clamp Meter. Users Manual

PRM-4. Phase Sequence and Motor Rotation Tester. Users Manual. For detailed specifications and ordering info go to

Power Inverter 400 MW Owner s Manual

LM-100 LM-120. Light Meters. Users Manual. For detailed specifications and ordering info go to

Thermometer models 02023/02028/02053/02054

NANOPAC-300 & 500 Power Supply. Instruction manual NANOPAC-300 & NANOPAC-500

KIT CONSISTS OF: FEATURES. S-Digit mini

TIC 300 PRO. Users Manual Mode d emploi Bedienungshandbuch Manual d uso Manual de uso. Non Contact AC Voltage Detector. High Energy Tic Tracer

Indoor Air Quality Meter

INSTRUCTION MANUAL DT173 DT175 DIGITAL THERMOMETERS ALWAYS READ THESE INSTRUCTIONS BEFORE PROCEEDING

IAQ-CALC TM Indoor Air Quality Meter

Matson Jump Starter Operator s Manual

60 Watt Industrial LED Low Bay Light

User's Guide. CO 2 Meter. Model CO250

Advanced Calibration Designs, Inc. Release II

LH41A. User Manual. Clamp On Ammeter. For detailed specifications and ordering info go to

JUMP STARTER OPERATOR S MANUAL RA1900

Thermometer model 00826

Owner s Manual & Safety Instructions

INSTRUCTION MANUAL DM383B Fax: (503)

Nature Power Inverters. True Sinewave Inverter Modified Sinewave Inverter. Owner s Manual

1662/1663/1664 FC. Electrical Installation Tester. Safety Information. Warnings

51 & 52 Series II. Users Manual. Thermometer. Test Equipment Depot Washington Street Melrose, MA TestEquipmentDepot.

323/324/325 Clamp Meter

Operating Manual COST CONTROL - POWER CONSUMPTION MONITOR

Thermometer models 02023, 02028, 02029

60V RECHARGEABLE LITHIUM-ION BATTERY

1.5W Solar Panel. Owner s Manual

i3000s/i2000 Flex AC Current Probe

Table of Contents. 1. The Statement Overview Instrument Familiarization Method of use General Specifications...

AXD 530 MicroManometer

Users Manual. MegOhmMeter

230VAC Power Inverter 400W Owner s Manual

Users Manual. Airflow Meter

TX900. Microwave Leakage Detector. 99 Washington Street Melrose, MA Phone Toll Free

BT403. A Geno Technology, Inc. (USA) brand name. BT-300 Power Supply. Cat. No. BT

Temperature Probe, Battery (installed), Instruction Sheet, Quick Reference Card and Warranty Card.

Components. Options Accessory Harness USB Charger. Quick Connector. Hook & Loop / Cable-ties. RFID Antenna. Module. Main Harness.

BK BK A BK MA BK MA BK J93 MN93-BK MN193-BK MR193-BK SL261-BK SR193-BK

Wireless Thermometer model 00782W

OPERATING MANUAL PLS HLE 1000 PACIFIC LASER SYSTEMS. The Professional Standard

User Guide. Model Insulation Tester / Megohmmeter. Introduction

Lemania/EnergyFlo Start booster X7

MOISTURE METER 2155 OPERATION INSTRUCTIONS VERSION 1.0

Defender 3000 Series Base Instruction Manual

709 Rev. 6.x Analyzers

Care and use guide. Contents. page

Video & Power Over Coax Kit

SSP-Series Portable Balances Operation Manual

IMPORTANT SAFETY INSTRUCTIONS

operating manual DL7 101 DIGITAL THERMOMETER

RS-3 PRO RS-1007 PRO. CAT IV Analog Clamp meter Series. Users Manual. For detailed specifications and ordering info go to

AC / 65 W M PLEASE READ BEFORE OPERATING THIS EQUIPMENT.

D Dräger Alcotest 3000 Breath Alcohol Measuring Device

CONTENT 1 PICTURE GENERAL... 3

8-Bay Rapid Charger. for AA/AAA NiMH & NiCd Rechargeable Batteries. Owner's Manual. Please read before using this equipment.

USER GUIDE. Model RH10 Hygro Thermometer. Humidity and Temperature Meter

AIR VELOCITY METER ALNOR MODEL AVM410 AIRFLOW INSTRUMENTS MODEL TA410

User's Manual. High Voltage Megohmmeter. Analog Insulation Tester plus AC Voltage and Continuity Tests. Model

Valor 1000W Series Instruction Manual. Serie Valor 1000W Manual de Instrucciones. Série Valor 1000W Guide de I utilisateur

Multi-Mover Charger for model L25

Instruction Manual. 99 Washington Street Melrose, MA Fax TestEquipmentDepot.com. Model 308A Digital Insulation & Continuity Meter

Model HPX60 Series Automatic Battery Charger User s Manual Rev. 1.0 October 17, 2006

12V Oil Extractor Pump

Model NTX7 Series Automatic Battery Charger User s Manual Rev. 1.0 October 17, 2006

Delmhorst Instrument Co. Model HT-3000 Thermo-Hygrometer. Owners Manual

OWNER S MANUAL TOLL-FREE HELPLINE: (Monday - Friday / 8am - 4:30pm CST)

MICROMANOMETER ALNOR MODEL AXD610 AIRFLOW INSTRUMENTS MODEL PVM610

40 V LITHIUM-ION BATTERY ATTACH YOUR RECEIPT HERE AB13786C 1. kobalttools.com ITEM # /


AUTOMATIC FAUCET INSTRUCTION MANUAL. Important Safeguards Precautions Model Number and Components. Before Use How to Use How to Adjust

TACH-10 Contact / Non-Contact Tachometer

SUNC3000 / Item #40885

Lumina 28 Traction Drive Model: Battery Burnisher M28036TDQP OPERATION SERVICE PARTS CARE

Transcription:

CO95 Carbon Monoxide Detector INSTRUCTION MANUAL ENGLISH CO95 C ARBON MONOXIDE DETECTOR 1-800-547-5740 Fax: (503) 643-6322 www.ueitest.com Email: info@ueitest.com

TABLE OF CONTENTS Introduction... 3 Safety... 3 Controls and Indicators... 4 Operating Instructions... 6 Before Using Every Time... 6 Appliance Measurements... 6 CFK1 Optional Chemical Filter Kit (NOx Filter)... 7 Ambient Air Measurements... 7 Printing Test Information... 7 After Using The Meter... 8 Troubleshooting... 8 Specifications... 8 Maintenance... 9 Periodic Service... 9 Cleaning... 9 Battery Replacement... 9 Electromagnetic Compatibility (EMC)... 10 Glossary of Terms... 10 Warranty and Service Information... 12 2

Introduction The CO95 is configured with a long-life CO sensor. The CO95 meter tests CO levels in heating appliances, ambient air, around fossil fueled appliances like cookers and grills. It also helps you test residential and commercial CO alarms and also shows CO MAX - the maximum level of CO measured. The CO95 can also be used as a digital thermometer, ideal for testing hot water or refrigeration. Features include Long-life (5 years) CO sensor Measure ambient CO levels Measure CO concentration in flue gas CO Max capture CO accurate to ±5% of reading Temperature measurement Auto-zero at power up Link to optional infrared printer Safety Notes Before using this meter, read all safety information carefully. In this manual the word WARNING is used to indicate conditions or actions that may pose physical hazards to the user. The word CAUTION is used to indicate conditions or actions that may damage this instrument. WARNING! This meter extracts combustion gases that may be toxic in relatively low concentrations. These gases are exhausted from the back of the instrument. This meter must only be used in well-ventilated locations by trained and competent persons after due consideration of all the potential hazards. 3

Controls and Indicators 1 3 2 5 4 6 7 8 9 10 11 CO95 C ARBON MONOXIDE DETECTOR 1. Power Push-button Press button to switch the unit ON in fresh air outside the property about to be tested. This lets the meter auto calibrate its sensors properly. When turned on the meter beeps four times and displays the top line date, time and model number. The bottom line counts down from 60 until the sensors are ready to use - This normally takes 20-30 seconds but may take longer as sensors get older. If the meter will not auto calibrate, its sensors need to be replaced or recalibrated by an authorized repair center. When countdown is finished the displays top line shows the last selected function and the bottom line displays whatever the rotary dial is turned to. Press button again to switch the meter OFF. The display counts down from 30 with the pump on to clean the sensors with fresh air - If the probe is still connected, make sure the meter and probe are in fresh air. Press HOLD/ENTER if you want to stop the countdown and return to taking measurements. 4

2. UP/DOWN/ENTER buttons Press the DOWN button for more than 1 second to change the displays top line. The rotary dial changes the displays bottom line. Example: The meter will display CO on its top line and temperature on its bottom line if you turn the rotary dial to TEMP and push the DOWN button until CO is displayed on the top line. Use the UP/DOWN/ENTER keys to change settings (such as time and date) when the rotary dial is turned to MENU. 3. PRINT/BACKLIGHT button Press and release PRINT/BACKLIGHT quickly to switch backlight on or off. Press for more than 1 second before releasing to start the meter printing. The meter will display PRINTING. 4. PUMP on/off button The meter normally operates with the pump on. Press PUMP quickly to switch the pump off and on. When the pump is switched off, the meter displays PUMP OFF approximately every 30 seconds. 5. Freezing the Display Press HOLD/ENTER to freeze all readings. The display flashes and can be printed by pressing PRINT key. Press HOLD/ENTER again for live measurements. 6. Menu Rotate the dial to MENU and use the UP or DOWN buttons to select the following function for change: 1. Time - Uses Military time as standard: 7am = 07:00, 7pm = 19:00 2. Date - Select from MM/DD/YY, YY/MM/DD or DD/MM/YY 3. The display s top line - select from the settings listed below 4. Temperature units - F or C 5. The display screen contrast 6. Language - select from English, French, Spanish, Italian and German 7. Service - Password protected for authorized service personnel only When you have selected the function to change, press ENTER to select. Repeat this as the menu drops down to select (using the ENTER key) and change (using the UP and DOWN keys) the function. The final, logical ENTER returns you to the main menu display. To exit the menu function at any time, rotate the dial to another position - Unless the final logical ENTER is pressed, no changes are made. 7. Time & Date: Displays time and date. 8. Temp: Displays the measured temperature in F or C. If the temperature sensor is broken or open circuit it displays 000. 9. CO: Displays Carbon Monoxide (CO) values in PPM. 10. CO MAX: Displays the maximum CO value in PPM recorded during the test 5

11. BAT: Displays estimated battery life. If battery voltage falls below a pre-set limit, the display flashes LOW BAT. every 10 seconds. Operating Instructions Before Using Every Time Check for the following: The particle filter is not dirty The water trap and probe line are empty of water All hose and thermocouple connections are properly made The probe is sampling ambient FRESH air The water trap and drain plug are fitted correctly to the instrument The temperature probe is connected if required Appliance Measurements Place the CO95 s probe into the appliance s sampling point. The ideal sampling point is at least two flue diameters downstream of any bend. Put the probe tip in the flue center. With balanced flue, make sure the probe is positioned far enough into the flue so no air can back flush into the probe. 2D D Boiler 2 2 Taking an appliance test Make sure you do not exceed the meter s operating specifications. In particular: Do not exceed the probe s maximum temperature Do not exceed the meter s internal temperature operating range Do not put the meter on a hot surface Do not exceed the water trap s levels Do not let the meter s particle filter become dirty and blocked Press HOLD first to freeze the readings before printing, then press PRINT. 6

CFK1 Optional Chemical Filter Kit (NOx Filter) CO sensors may respond to gases other than CO, resulting in slightly elevated readings. On low NOx equipment this impact will be very small, often less than the tolerance of your meter. If you anticipate high levels of SO2 or NOx, UEi recommends using our CFK1, in-line chemical filter. The CFK1 will remove NOx and SO2 from the gas sample, allowing a true view of the CO only. The CFK1 is compatible with most portable CO and Flue Gas Analyzers, installs on the sample line before the instrument, and need for replacement is easy to determine. Ambient Air Measurements When testing for CO in rooms, make sure the meter has been switched on in outdoor fresh air before the meter is calibrated. After the countdown is finished and the meter is correctly set up, take the meter into the room to be tested, make sure its pump is on and use the probe to draw in ambient air for the meter to measure. Only switch on the meter in OUTDOOR, FRESH AIR Do not exceed the meter s internal temperature operating range Do not put the meter on a hot surface Do not expose yourself and others to dangerous levels of CO Printing Test Information An optional accessory for the CO95 is an infrared thermal printer. Read the manual supplied with the printer prior to operation. Connection to the CO95 is detailed below. Infrared thermal printer - this does not require a cable to transmit the data but uses an infrared (IR) link similar to a TV remote control. The IR emitter is positioned on the top of the CO95 and the bottom of the printer. Ensure they are pointing at each other and within 3 feet (1 meter), with no obstructions in the way. Data may be lost if transmission is interrupted. Keep the CO95 pointing at the printer until the printout has finished. During tests the CO95 will print data on request. With the analyzer showing the MAIN DISPLAY press and current data will be sent to the printer. The display will show PRINTING until data transmission is complete. 7 UEI CO95 503 644 8723 06-26-02 14:27 SMOKE: NATURAL GAS CO PPM 00 CO MAX PPM TEMP. F ----

After Using The Meter After using the meter to test appliances, remove it s probe from the flue - IT WILL BE HOT - and let it cool. Do not put the probe in water which will be sucked into the meter, damaging its pump and sensors. When the meter readings return to ambient levels, turn the meter off. The meter counts down from 30 before switching off with the pump running to self-clean its sensors. Empty the water trap and check filter prior to storage and next use. Troubleshooting If I See This Malfunction CO sensor Error (----) Batteries not holding charge Meter not running on main adapter Meter does not respond to flue gas Erratic temperature readings or 000 on display Then Take This Corrective Action Meter was stored in a cold environment and is not at normal working temperature CO sensor needs replacing Batteries exhausted AC charger not giving correct output Water trap drain plug not installed Particle filter blocked Probe or tubing blocked Pump not working or damaged with contaminants Temperature plug reversed in socket Faulty connection or break in cable or plug General specifications Specifications Parameter Resolution Accuracy Range Temperature 1.0 F/C ±5.0 F (2.0 C) 32-1112 F Measurement ±0.3% reading 0-600 C Carbon Monoxide (CO) measurement Dimensions Weight Handset Probe Ambient operating range Battery life AC adapter (optional) 1 ppm ±10 ppm <100 ppm ±5% of reading >100 ppm 0-1000 ppm 2.2 lb./1 kg 7.9 (L) x 1.8 (D) x 3.5 (W) (200 mm x 45 mm x 90 mm) 11.8 (L) x 0.25 (Dia) with 7.8 long stainless steel shaft (300 mm x 6 mm with 200 mm long stainless steel shaft) 32 to 104 F (±0 to + 40 C) 10% to 90% RH non-condensing 4 AA cells > 8 hours using Alkaline AA cells Input: 110 V AC/220 V AC nominal, Output: 9 V DC regulated 8

Maintenance Periodic Service WARNING! Repair and service of this instrument is to be performed by qualified personnel only. Improper repair or service could result in incorrect or erroneous reading from the meter. Perform only those maintenance tasks that you are qualified to do. These guidelines will help you attain long and reliable service from your meter: Calibrate your meter annually to ensure it meets original performance specifications Keep your meter dry. If it gets wet, wipe dry immediately - Liquids can degrade electronic circuits Whenever practical, keep the meter away from dust and dirt that can cause premature wear Although your meter is built to withstand the rigors of daily use, it can be damaged by severe impacts - Use reasonable caution when using or storing the meter Cleaning Periodically clean your meter s case using a damp cloth. DO NOT use abrasive, flammable liquids, cleaning solvents, or strong detergents as they may damage the finish, impair safety, or affect the reliability of the structural components. Battery Replacement Always use a fresh replacement battery of the specified size and type. Immediately remove the old or weak battery from the meter and dispose of it in accordance with your local disposal regulations. Batteries can leak chemicals that corrode electronic circuits. If your meter is not going to be used for a month or more, remove and store the battery in a place that will not allow leakage to damage other materials. To install a new battery, follow these procedures: 1. Turn off the meter. 2. Remove the rubber boot from the meter, starting at the top. 3. Place meter face down on a clean cloth. 4. Remove battery compartment cover. 5. Remove and discard the old batteries. Always dispose of old batteries promptly in a manner with local disposal regulations. 6. Insert (4) AA alkaline batteries noting + and - diagram directions in battery compartment. WARNING! Under no circumstances should you expose batteries to extreme heat or fire as they may explode and cause injury. 9

Electromagnetic Compatibility (EMC) European Council Directive 89/336/EEC requires electronic equipment not to generate electromagnetic disturbances exceeding defined levels and have adequate immunity levels for normal operation. Specific standards applicable to this meter are stated below. As there are electrical products in use pre-dating this Directive, they may emit excess electromagnetic radiation levels and, occasionally, it may be appropriate to check the meter before use by: Use the normal start up sequence in the location where the meter will be used. Switch on all localized electrical equipment capable of causing interference. Check all readings are as expected. A level of disturbance is acceptable. If not acceptable, adjust the meter s position to minimize interference or switch off, if possible, the offending equipment during your test. At the time of writing this manual UEi and Kane International Ltd are not aware of any field based situation where such interference has occurred and this advice is only given to satisfy the requirements of the Directive. This product has been tested for compliance with the following generic standards and is certified to be compliant. EN 50081-1 & EN 50082-1 Specification EC/EMC/KI/C100A details the specific test configuration, performance and conditions of use. Glossary of Terms TEMP: Temperature measured by the probe in Fahrenheit ( F) or Centigrade ( C). It displays ---- if the probe is disconnected. CO: Carbon Monoxide reading displayed in ppm (parts per million). ---- is displayed if there is a fault with the CO sensor or the meter has not set to zero correctly, switch off meter and try again. CO MAX: Maximum CO level recorded while the meter is switched on. BAT: Displays battery power available in %. When the BAT symbol is nearly empty it indicates the batteries are at less than 10% of charge and should be replaced, readings may be affected if used with low batteries. DATE: Date order can be changed using the menu function. Date is recorded when each combustion test is printed. TIME: Time is shown in hours and minutes, expressed in Military time or the 24hr clock. Time is recorded when each combustion test is printed. 10

CO95 Carbon Monoxide Detector Limited Warranty The CO95 is warranted to be free from defects in materials and workmanship for a period of five years from the date of purchase. If within the warranty period your instrument should become inoperative from such defects, the unit will be repaired or replaced at UEi s option. This warranty covers normal use and does not cover damage which occurs in shipment or failure which results from alteration, tampering, accident, misuse, abuse, neglect or improper maintenance. Batteries and consequential damage resulting from failed batteries are not covered by warranty. Annual calibration is not covered as a warranty item. Any implied warranties, including but not limited to implied warranties of merchantability and fitness for a particular purpose, are limited to the express warranty. UEi shall not be liable for loss of use of the instrument or other incidental or consequential damages, expenses, or economic loss, or for any claim or claims for such damage, expenses or economic loss. A purchase receipt or other proof of original purchase date will be required before warranty repairs will be rendered. Instruments out of warranty will be repaired (when repairable) for a service charge. Return the unit postage paid and insured to: 1-800-547-5740 FAX: (503) 643-6322 www.ueitest.com Email: info@ueitest.com This warranty gives you specific legal rights. You may also have other rights which vary from state to state. PLEASE RECYCLE Copyright 2013 UEi. All Rights Reserved 17031 08/13