Tricon by MCE. Car controller specification. Controller Data Form Motion Control Engineering JER Phone Fax

Similar documents
Tricon by MCE Data Form Motion Control Engineering Phone (916) Fax: (916)

IMC/PTC Elevator Data Forms

Logistics Information

Logistics Information

Logistics Information

Logistics Information

Motion 4000 Traction Engineering Survey Form

icontrol Traction Engineering Survey Form

Warning: Review Before Submittal

Standard VVMC-1000 or VFMC-1000 controls, dispatched by an M3 Group System, allow group configurations with 64 landings and as many as 12 cars.

Warning: Review Before Submittal

PLEASE COMPLETE AND RETURN AS SOON AS POSSIBLE

AMI-300 SERIES ELEVATOR CONTROLLER OPERATION, SERVICE & MAINTENANCE MANUAL

DRIVE STARTUP MANUAL. Magnetek HPV900-S2 Drive. PM Motor Installation

Fincor Series 2230 MKII/2240

ELEVATOR S GENERAL FUNCTIONS GUIDE

GUIDE 200.V2 VSD VERTICALLY CONTROL SYSTEM & INTERFACE GUIDE. 202 Standard Operation 202 Slave Mode 201 Sequence of Operations

231.V1 GUIDE VSD. CONTROL SYSTEM & INTERFACE GUIDE C/W TDP (Total Door Protection) Dual Light Curtains

Documents index. TRICON Control Systems Inc rd. Ave., Unit F, Glendale, NY Phone: (718) Fax: (718)

Motion Control Engineering, Inc White Rock Road Rancho Cordova, CA 95742

Model ESV Uninterruptible Power System 1.5 KVA/KW KVA/KW Single Phase

Motion Control Engineering, Inc White Rock Road Rancho Cordova, CA 95742

Motion Control Engineering, Inc White Rock Road Rancho Cordova, CA 95742

MaxPak Plus Analog DC V S Drive

QUICK LOCATOR GUIDE / fax

Magnetek DSD 412 Drive

RVS-DN Digital Reduced Voltage Motor Starter

825-P Modular Protection System for motors Specification Guide

RVS-DX Digital Reduced Voltage Motor Starter

DC3N Non-Regenerative DC Drives

EQUIPMENT INSTALLATION MANUAL

PART NO CP-DOOR FRONT PANEL WINDOW PART NO CP-DOOR FRONT PANEL SECOND WINDOW PART NO CP-DOOR LOCK PART NO. 5026

SE-3SCR-LM MANUAL MOTOR LOAD MANAGER

CUSTOMIZED OPTIONS FOR 1-WEEK DELIVERY

224-EN WIRELESS CONTROLLER INSTALLATION & INTERFACE GUIDE. Guide No. 224-EN USING AS REPLACEMENT CONTROLLER

1/6 through 5 HP Adjustable Speed, DC Motor Controllers

TECHNICAL MANUAL AND ELECTRONICAL MODULE REGULATION VVVF-4 +

REVISIONS. App Thom. App Sud. App PC T.C. 2013/10/01

Enquiry Sheet for LiSA-Lift Controller to EN81. Tel: Fax:

SECTION MOTOR CONTROL

AIS 5000 UPS kva 480 V. Installation Manual

NEMA 1, NEMA 4X and Chassis Mount Adjustable Speed Controls for DC Motors

Medium Voltage Standby non-paralleling Control GUIDE FORM SPECIFICATION

Mobile Generator MMG25FHI Specifications

WARREN COUNTY, N.Y. M/E REFERENCE

Magnum Mobile Generator MMG75 SS Specifications

EQUIPMENT INSTALLATION MANUAL

GUIDE 239 VSD VERTICALLY SERIAL CONTROLLER INSTALLATION & INTERFACE GUIDE. Guide No. SLIDING DOORS

SMS PRODUCT CATALOGUE

B100S - Super Swing. Instruction Manual. Document number: B100S-C Release: V4.0 Date: May 08,2009

ELVORON HOME ELEVATOR

Burden Fuse Rating Resistor SAF / SAK6 1NM 10mm M8 12NM SAF / SAK10 2NM 16mm M8 12NM

Magnum Mobile Generator MMG75 Specifications

AT30 SERIES BATTERY CHARGER

Home Elevator. Planning Guide

MODEL 520 REMOTE START ENGINE MANAGEMENT SYSTEM

I N D I A N S T A T I S T I C A L I N S T I T U T E

Commercial & Residential

User Manual. T6 Tachometer. Online: Telephone: P.O. Box St. Petersburg, Florida 33736

ARCHITECTURAL CONTROL SYSTEMS, INCORPORATED ST. LOUIS, MISSOURI

TECHNICAL DATA SHEET KVA UPS Systemss

POWER+ PREMIUM CBS. BS-EN Emergency electrical installations Electric power systems Emergency lighting Escape lighting

Fincor DC Drives. Flexible & Powerful TYPICAL APPLICATIONS. Conveyor Rugged. Extruder Reliable. Conveyor Simple. Mixer Flexible

User Guide, SmarTraq Limitless Door Operator with Revision 7 Drive

Hollister-Whitney Elevator Corporation

DRAFT 1400HP 1000HP 100HP. Reduced Voltage Solid State Starters. Softstarters SOFT. PF Controller PCS Controller PDS Controller V 1...

Horizontal Circuit Switchers

Magnum Mobile Generator MMG125 Specifications

Horizontal Circuit Switchers

WORLD electronics GFC-IIA. Manual Kutztown Road Reading, PA

Open Chassis Star-Delta Starter User Guide

INSTALLATION INSTRUCTIONS

Belt Scales Table of Contents

Ch 4 Motor Control Devices

WARREN COUNTY, N.Y. M/E REFERENCE A. Submit manufacturer's product data on all motors and adjustable speed drives.

Orion LU/LA Commercial Elevator OWNER S MANUAL

Microlift: complete view. STANDARD SHAFT HEIGHT (in mm) GENERAL TECHNICAL SPECIFICATIONS GEAR MACHINE AND CONTROLLER MACHINE ROOM CAR REMOVABLE SHELF

Observe all necessary safety precautions when controlling the soft starter remotely. Alert personnel that machinery may start without warning.

Softstarters Type PSS. Softstarters. General information

EQUIPMENT INSTALLATION MANUAL

2.1 Warnings & Agency Approvals Electrical Connections - Specifications Standard Wiring Configurations...2 4

DENISON HYDRAULICS Jupiter 500 Driver Card Series S

SECTION MOTORS & MOTOR CONTROLLERS

DC3E Non-Regenerative DC Drive User Guide 1/4 to 2 HP, 115/230 VAC M/N DC3N-12D AI M/N DC3N-12D-4X-010-AI

INSTALLING, OPERATING AND MAINTAINING THE MODEL D1028 COMPUTER INPUT BI-DIRECTIONAL GENERATOR FIELD REGULATOR INSTRUCTION MANUAL # S-225

Gate & Door Controller with LCD and Intelligent Technology

Crane Control Class 5010

This specification describes the minimum requirements for a hoist maintenance safeguard (HMS) system for mine hoists.

AQUASTAR C6. (Comfort 6000) Next Generation Auto Backwash Valve System. (selectable time-pressure or remote cycle start)

ABB Drives ACS550-U1-059A-2, 20 HP, 3PH, 200 VAC, Wall Mount VFD

Installation and Maintenance Instructions. World Leader in Modular Torque Limiters. PTM-4 Load Monitor

SE2000BX Static Exciter

SECTION V SWITCHBOARD I 4 Engine/Gen Control Cubicles II 1 Synchronizing System III 1 Ground Detection Network IV 1 600V Feeder Section V 2

60 Series Engine Controls

Swift Futura SECTION 2 - FUTURA STARTUP PROCEDURES HPV MACHINE ROOM PREPARATIONS. Field Wiring Check STARTUP PROCEDURE HPV. Cab Circuit Lighting

MEDIUM VOLTAGE PRODUCT CAPABILITIES OVERVIEW

GALAXY IV Controller Conformance Document and Compliance Test Procedure

ReSolve Traction Effective Model Solutions SSB...First Choice!

Technical Data Sheets

ilearn System Manual

Transcription:

Motion Control Engineering JER119 0810 Phone 916.463.9200 Fax 916.463.9201 Car controller specification Foreword Document revision date: 06/01/10 Please fill all ten pages completely. It is very important to include ALL information to assure an accurate price quote and controller configuration. The standard indicator voltages are 24VDC or 110VDC, high side outputs. Note: Cars having different speed, capacity, motor data or openings require separate data sheets. General data Date: Customer Company Name: Contact / Survey by: Phone: Approval Signature: Job Job name Job address Car name Delivery date Shipping Address Fax: Date: Controller to be picked up at MCE Yes No Shipping address same as your office Yes No Company Name: Ship Address: Note: CE Micro Com driver supplied by MCE for Tricon will operate a maximum of four displays. If five or more displays are used, Heavy Duty CE provisions are required at additional charge. If you are providing a digital display driver, the inputs will be +24VDC, binary starting with one at the bottom floor. Elevator Safety Code Compliance Project Type: New construction Modernization Measurements: U.S./English S.I./Metric Compliance ASME A17.1-2007 A17.1-2004 A17.1-2000 ASME A17.1-1996/98 (If 98 addendum on multi-car installation, provide details on machine room/hoistway configuration page 6 or on a separate sheet of paper.) ASME A17.1- Specify code and addenda. International compliance Canada B44-07 B44-04 B44-00 : Phone / Contact: Lift Gate Required Yes No Flat bed Truck Required Yes No Notice Required 24-Hr 48-Hr Specification Not provided Consultant Company: Name: Phone: Yes, Number of pages: Fax: Elevator type Passenger Simplex Simplex W/ Emg Power Service Freight Car Switch Group car w/sep dispatcher box Car speed: Fpm Load Capacity: Lbs Note: All multi car groups and simplex cars with emergency power or Hospital Code Blue require a separate dispatcher box. Page 1 of 11

Motion Control Engineering JER119 0810 Phone 916.463.9200 Fax 916.463.9201 Power line Note: The following voltages are 60 HZ 3 phase 208 VAC 220 VAC 440 VAC 460 VAC 480 VAC 575 VAC 220 VAC 60 Hz single phase 600 VAC : 240 VAC Control type VV-MG (Fill page 7) VVVF open loop (Fill page 10) VVVF/VFD closed loop (Fill page 10) VV-SCR control (Fill page 9) Hydraulic (Fill page 11) Control options Cabinet door hinge mounting (circle one): Car #: Car #: LEFT SIDE RIGHT SIDE Pre-wired car station (serial link) Remote car top box (serial link) Cabinet legs 18 (HPV600, Hydro only) Cabinet Stands 4 (HPV900,SCR,MG) Air Conditioning Hand held units, quantity Note: A Tricon pre wired car station w/ I/O boards installed requires the remote car top box option. The car station must be shipped to MCE for wiring. Remote car top box only is acceptable. Page 2 of 11

Riser description (NO SHORT FLOORS ALLOWED) Floor OVERH 32 31 30 29 28 27 26 25 24 23 22 21 20 19 18 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 PIT Floor height Floor marking OPENINGS SIMPLEX HALL CALLS / IR GROUP HALL CALLS LOCKOUTS Front Rear Up Down Rear Rear Up Down Rear Rear Front Rear Up down up down Floor marking: Front opening: Local hall up: Local hall down: Rear opening: Local rear hall up: Local rear hall down: The floor identification in the building The car has a front door at the floor. The car is simplex and has a hall up call or has a hall independent riser up call at the floor. The car is simplex and has a hall down call or has a hall independent riser down call at the floor. The car has a rear door at the floor. The car is simplex and has a rear door hall up call or has a hall independent riser rear up call at the floor. The car is simplex and has a rear door hall down call or has a hall independent riser rear down call at the floor. Shaft data Total shaft height Car #1 feet Car #2 feet Selector tape length Car #1 feet Car #2 feet Selector tape length should be the total shaft height, from the pit floor to the motor room floor. Page 3 of 11

Lobby signals and devices Lobby Position Indicator Lamps Dir. Arrows Yes No CE MicroCom driver (provided by MCE) CE MicroCom driver (provided by customer) E-Motive driver (provided by MCE) Hall signals and devices Hall Indicators Position Indicators, ( than lobby) CE Display (Max. 4 displays) CE Display Heavy Duty (5 or more displays) Add.chg. Analog lamps (Max. 3 lamps) Analog lampsheavy Duty(4 or more lamps) Add.chg. Dir. Arrows: Yes No CE MicroCom driver (provided by MCE) CE MicroCom driver (provided by customer) E-Motive driver (provided by MCE), specify: In-use light If Yes, voltage Hall Direction Arrows ( than Pos. Ind.) If Yes, voltage Hall Lanterns Yes If Yes, voltage Hall Call Pushbuttons Car switch operation with hall calls and in car annunciation Switch type, no Ack. light Switch type, Ack. Lights Page 4 of 11

Car station signals and devices Car call pushbuttons Switch type, no Ack. lights Switch type, Ack. Lights Car station position indicator Lamps Dir. Arrows: Yes No CE MicroCom driver (provided by MCE) CE MicroCom driver (provided by customer) E-Motive driver (provided by MCE), specify Attendant in Car Annunciators No Yes Audible signal (Buzzer only) Visual signal (Panel in car or hall to indicate hall calls) NOTE: Provided only with car switch operation. If Yes, voltage Auxiliary Car Station No Yes Buzzers Fire buzzer Nudging buzzer Use fire buzzer Passing chime Use fire buzzer switches Car insp. sw. (required for access) Yes No Attendant up-down buttons Yes No Attendant direction arrows Yes No Attendant bypass button Yes No S Handicap Chime Enable Button Yes No Car Call Lockouts Yes No Which Floors Car Call Lockout Type Key switch Cardreader Car Call Lockout Location Car Station Remote NOTE: All lockout key switches located in car station sent to MCE for pre-wiring will be wired in car station to car buttons unless otherwise stated. Remote locks will be wired to input card on controller. Car signals and devices, other than car station Car position indicator (In transom) Lamps Dir. Arrows: Yes No CE MicroCom driver (provided by MCE) CE MicroCom driver (provided by customer) E-Motive driver (provided by MCE), specify Car arrival lanterns and gong Lamps Page 5 of 11

Front Door Car door type Manual door Master door Freight Door operator New Existing SmarTraq Complete DO SmarTraq Upgrade Kit GAL MODCT GAL MOMCT GAL MOD (230V shunt) GAL MODP(swing) GAL MODPM GAL MOMSVL GAL MOVFR GAL MOM / MOH MAC / ECI (Electronic) Moline (Resistor) Schindler QKS-14or15 Courion Peelle (Auto open) Peelle (Auto O and C) EMS Include door operator prints Note: Supply prints for all freight operators. Note: Tricon standard for GAL MOCT type operators is 208VAC supply and 110 VDC relays Rear Door Car door type Manual door Master door Freight Door operator New Existing SmarTraq Complete DO SmarTraq Upgrade Kit GAL MODCT GAL MOMCT GAL MOD (230V shunt) GAL MODP(swing) GAL MODPM GAL MOMSVL GAL MOVFR 110VAC 220VAC (220 is default if no selection made) GAL MOM / MOH MAC / ECI (Electronic) Moline (Resistor) Schindler QKS-14or15 Courion Peelle (Auto open) Peelle (Auto O and C) EMS Include door operator prints Note: Supply prints for all freight operators. Door Detector interface Standard (detectors which close dry contact), describe Hall doors type Manual Driven by car door (automatic) Swing door with 2 circuit locks Freight door Door retiring cam New Existing Mechanical Electrical Two circuit door locks GAL 220 VAC, volts Motor Coil Pick volts Resistance ohms Note: Tricon standard for GAL MOCT type operators is 208VAC supply and 110 VDC relays Door Detector interface Standard (detectors which close dry contact), describe Hall doors type Manual Driven by car door (automatic) Swing door with 2 circuit locks Freight door Door retiring cam New Existing Mechanical Electrical Two circuit door locks GAL 220 VAC, volts Motor Coil Pick volts Resistance ohms Page 6 of 11

Car special operations Fireman s operation ANSI 17.1 Version - NYC operation Master Fire Service switch (Chicago only) (Please describe) Fire recall floor Rear door Smoke detectors Alternate recall floor Rear door Smoke bypass switch Yes No Hoistway Access switch Top floor Yes Bottom floor Yes floor Note: An inspection switch in the car is required, as well as hoistway limit switches. Special services Attendant Independent service Inconspicuous Riser(IR) Car# Earthquake Cross Cancel Lobby recall Floor Rear door Load Weigh unit (K- Tech) Emg Power (Disp required) Color Lobby Display Master Control Key Sw. for schools Sabbath Feature Hosp. Code Blue (Disp. required) Rope Gripper (GAL) Monitoring Systems Lift-Net O. Thompson CLD (Display up to two groups/simplexes) List all cars in all groups/simplexes to be displayed/monitored: Monitor Options: 17 LCD : Printer (Lift-Net only) Number of machine-room and lobby monitoring stations: 0 1 : (Lift_Net only) Machine room or lobby monitoring station connectivity: Line Drivers Cat 5 (line driver replacement only; not connected to building LAN; Lift-Net only) Cat 5, connected to building LAN (Lift-Net only) If connected to building LAN, provide static IP addresses for all monitoring stations and all monitored group/simplex controllers (see NOTE) Number of remote location monitoring stations (Lift-Net only): 0 (At least one machine room or lobby monitoring station must be selected above). Number: Approx distance between remote monitoring stations and controllers: Remote location monitoring station connectivity (Lift-Net only): Dedicated dial-up lines. Phone numbers: WAN Static IP addresses for all monitoring stations (machine room, lobby, remote location) and all monitored group/simplex controllers (see NOTE) NOTE: MCE is not responsible for required parts and/or labor external to the monitoring system, controllers, and PC-controller interface, such as routers, cable modems, or field wiring to enable communications using the specific IP addresses provided by the customer. Page 7 of 11

VV-MG control Machine Location Geared Overhead Gearless Basement Drum Brake AC DC Specify either voltage or current; no need to specify both. Lift volts amps Hold volts amps Relevel volts amps Resistance ohms DC Hoist Motor Frame Type Amps: Nom. Volts H.P. RPM Hoist motor shunt field Specify either voltage or current; no need to specify both. Standing volts amps Full field volts amps Running volts amps Resistance ohms Note: All complete motor & brake info must be provided to avoid delays in processing. DC Motor Generator Generator Driving Motor Frame Type Amps: Nom. Volts AC DC H.P. RPM Starter Across the line Wye-delta, describe Generator Data Frame Type K.W. Voltage volts Current amps Generator Shunt Field Running data volts amps Resistance ohms DC Tachometer Provided by MCE, DC Tachometer, and coupling Base mount Flange mount Select a coupling below if MCE is providing the tach 5/16 X ¼ 5/16 X 5/16 5/16 X 3/8 5/16 X 7/16 5/16 X 1/2 (Default diameter = 1/4 ) Provided by motor manuf. when installing a new motor Note: The tach provided by the motor manufacturer should be 100VDC per 1000RPM. The motor manufacturer should provide the mounting and couplings. The tach provided by MCE includes tach, coupling. Note: All complete motor & brake info must be provided to avoid delays in processing. Page 8 of 11

SCR control Machine Location Geared Overhead Gear-less Basement Drum Brake AC DC Specify either voltage or current; no need to specify both. Lift volts amps Hold volts amps Relevel volts amps Resistance ohms DC Hoist Motor Frame Type Amps: Nom. Volts H.P. RPM Hoist motor shunt field Specify either voltage or current, no need to specify both. Standing volts amps Full field volts amps Running volts amps Resistance ohms Drive Provide choke Yes No Encoder Tachometer Provided by MCE, encoder, coupling and cable Select a coupling below if MCE is providing the encoder 3/8 X ¼ 3/8 X 3/8 3/8 X 7/16 3/8 X 1/2 (Default diameter = 1/4 ) Provided by motor manuf. when installing a new motor Note: The encoder provided by the motor manufacturer should be 5VDC differential 150MA, 2 channel quadrature, (A, A not, B, B not). The motor manufacturer should provide the mounting, couplings, and cable. The encoder provided by MCE includes encoder, coupling and cable. Note: All complete motor & brake info must be provided to avoid delays in processing. Isolation Transformers & Chokes shipped to customer directly from manufacturer: Yes No Isolation Transformers & Chokes: Stackable Non-Stackable Page 9 of 11

VVVF / VFD Control Machine Location Geared Overhead Gear-less Basement Drum Brake AC DC Specify either voltage or current; no need to specify both. Lift volts amps Hold volts amps Resistance ohms Hoist motor Amps: Nom. Volts H.P. RPM Drive Open loop configuration (no encoder) Closed loop configuration (cable, encoder and coupling may be provided, see the encoder selection box below) Encoder Tachometer Provided by MCE, encoder, coupling and cable Select a coupling below if MCE is providing the encoder 3/8 X 5/16 3/8 X 3/8 3/8 X 7/16 3/8 X ½ 3/8 X ¼ (Default diameter = 1/4 ) Provided by motor manuf. when installing a new motor Note: The encoder provided by the motor manufacturer should be 5VDC differential 150MA, 2 channel quadrature, (A, A not, B, B not). The motor manufacturer should provide the mounting, couplings, and cable. The encoder provided by MCE includes encoder, coupling and cable. Note: All complete motor & brake info must be provided to avoid delays in processing. NOTE: Only when using HPV600 drive at 100FPM with remote car top box and floors in line Tricon can provide slowdown magnets on the leveling unit (IP9600) to eliminate the need to mount mechanical switches in the hatch. IP9600 w/slowdowns SET9000 Page 10 of 11

Hydraulic control Pump Motor Frame Type Amps: Nom. Volts H.P. RPM Tandem pumps If Yes, how many Tandem Valves If yes, provide a description of the desired pump starting and valve sequence. Valve Coils voltage volts AC DC Number of coils Sequence: Up fast Up slow Down fast Down slow Note: Tricon provides a standard valve sequence. Both valves, fast and slow are energized in high speed. When the car slows down, high speed is dropped, and the slow speed valve remains energized, until the car levels to the floor. Starter Starters provided by Tricon (select one below) ATL Wye-Delta (see Note 2 below) Soft Starter (see Note 1 below) 3 Wire Motor 6 Wire Motor Note 1: Separate Enclosure provided for all Soft Starters. Contact MCE Engineering for details. Note 2: Separate starter enclosures are required for larger starter sizes. Contact MCE Engineering for details. If re-using existing indicate which: ATL Wye-delta Soft-starter Note: If re-using existing, may require rewiring to Tricon standard interface. (Provide prints for existing starter or Softstarter) Rescuvator interface type: GAL Reynolds & Reynolds Low pressure switch High temperature switch Page 11 of 11