NET METERING ENROLLMENT APPLICATION REFERENCE GUIDE

Similar documents
Net Metering Rate Option for Self-Generators

Definitions. Scope. Customer Generation Interconnection Requirements

White River Electric Association, Inc. Net Metering Information & Service Requirements

Net Metering in Ontario POWER YOUR ELECTRICITY NEEDS AND MANAGE YOUR ENERGY COSTS.

Rider : NET METERING SERVICE AND ELECTRICAL SYSTEM INTEGRATION

BC Hydro Rate Schedule 1289 Revision 1 Effective: April 20, 2018 Page 6-1

RULE 21 GENERATING FACILITY INTERCONNECTION APPLICATION SMUD s Distribution System - (SMUD FORM 2655)

TERMS AND CONDITIONS

Application to Amend Net Metering Service under RS Appendix B. Revised RS 1289 Clean and Black-lined

RENEWABLE ENERGY PROGRAM Step 1, Section 1 ENROLLMENT FORM FOR LEASED RESIDENTIAL AND SMALL COMMERCIAL PHOTOVOLTAIC AND WIND TURBINE SYSTEMS

DISTRIBUTED RESOURCE GENERATION Feed-In-Tariff Single Phase

Form C Renewable Energy Micro-Generation Connection Application Distribution System

Columbia Water & Light Interconnection & Net Metering Agreement Electrical Facility

Net Metering POWER YOUR ELECTRICITY NEEDS AND MANAGE YOUR ENERGY COSTS. Tri Canadian Energy

SCHEDULE NO. ACG33 NET METERING SERVICE

Louisville Gas and Electric Company

Bulletin Interconnection of electric power production sources Rules 2-010, , , , , , and

BC Hydro Rate Schedules Effective: August 1, 2015 Fourth Revision of Page 30

3. Customer shall provide space for metering equipment and meter base as per Springville City Power requirements.

Municipality Generator Interconnection Application Single Meter Application Part I

GENERATOR INTERCONNECTION APPLICATION

NORTH CAROLINA INTERCONNECTION REQUEST APPLICATION FORM. Utility: Duke Energy Progress

Net Metering Service. Customer Information Package

SCHEDULE 84 CUSTOMER ENERGY PRODUCTION NET METERING SERVICE

PSNH INTERCONNECTION REQUEST

INTERCONNECTION STANDARDS FOR CUSTOMER-OWNED GENERATING FACILITIES 25 kw OR LESS PUBLIC UTILITY DISTRICT NO. 1 OF CHELAN COUNTY

P.S.C.U. No. 50 Original Sheet No ROCKY MOUNTAIN POWER ELECTRIC SERVICE SCHEDULE NO. 136 STATE OF UTAH

Information Packet Kissimmee Utility Authority Customer-Owned Renewable Generation Interconnection And Net Metering Program

D.P.U A Appendix B 220 CMR: DEPARTMENT OF PUBLIC UTILITIES

Duke Energy Carolinas North Carolina Interconnection Request Checklist

SOLAR ELECTRIC INVESTMENT ANALYSIS

Net Metering in Illinois. Eric P. Schlaf Senior Economic Analyst Illinois Commerce Commission January 31, 2014

NET METER REQUEST FORM

Louisiana Net Metering Service. Customer Information Package

Legal Name of the Customer (or, if an individual, individual's name): Name: Contact Person: Mailing Address: Physical Address: City: State: Zip Code:

APPLICATION FOR INSTALLATION OF SMALL SCALE EMBEDDED ELECTRICITY GENERATION

ENERGY STRATEGY FOR YUKON. Net Metering Policy DRAFT FOR CONSULTATION

Micro-Generation Connection Application For Connection of Micro-Generation Facilities of 10 kw

NET METERING APPLICATION

Xcel Energy Guidelines for Interconnection of Electric Energy Storage with the Electric Power Distribution System

Umatilla Electric Cooperative Net Metering Rules

New Ulm Public Utilities. Interconnection Process and Requirements For Qualifying Facilities (0-40 kw) New Ulm Public Utilities

Application for Interconnection and Net Metering Revision: 1 Revised: November 7, 2017

SCHEDULE 6 RESIDENTIAL SERVICE ON-SITE GENERATION

First Revision of Sheet No P.S.C.U. No. 50 Canceling Original Sheet No ROCKY MOUNTAIN POWER ELECTRIC SERVICE SCHEDULE NO.

KAUAI ISLAND UTILITY COOPERATIVE KIUC Tariff No. 1 RULE NO. 17 NET ENERGY METERING

Level 2, Level 3 & Level 4 Interconnection Request Application Form (Greater than 25 kw to 10 MVA or less)

SERVICE CLASSIFICATION "CEF" COMMUNITY ENERGY FACILITY

A Bill Regular Session, 2015 HOUSE BILL 1004

City Title. . Is System Owner interested in being contacted about energy efficiency opportunities at this site? Title. City. Site Contact.

3.0 Radial Distribution Systems

Northeastern Rural Electric Membership Corporation Columbia City, Indiana

M.P.S.C. No. 2 Electric Third Revised Sheet No. 65 (Rate Case) Cancels Second Revised Sheet No. 65

Please Refer to Attached Sample Form

Net Metering Interconnection Requirements. Customer Generation Capacity Not Exceeding 100 kw. Date: Version: 1

PUBLIC SERVICE COMMISSION OF WEST VIRGINIA

London Hydro Connection Checklist

WEB ENABLE ONLINE DATA LOGGER AND REMOTE MONITORING FOR 66 KW ON GRID SOLAR PV SYSTEM

CATEGORY 2 GENERATOR INTERCONNECTION APPLICATION

California PUC Rule 21 Generating. Facility Interconnection Application Guide. Technical Note

TERMS AND CONDITIONS XXV. NET METERING CUSTOMERS AND SMALL AGRICULTURAL GENERATORS

ROANOKE ELECTRIC COOPERATIVE RATE SCHEDULES

NET ENERGY METERING RIDER Rider NEM. Certain words, when used in this Rider NEM shall be understood to have the following meanings:

Electric Utility Contact Information Indiana Michigan Power

Xcel Energy Guidelines for Interconnection of Electric Energy Storage with the Electric Power Distribution System

Superseding Revised Sheet No. 63 REVISED SHEET NO. 63 Effective March 1, 2011 Effective September 1, 2012 ENERGY COST ADJUSTMENT CLAUSE

Xcel Energy Guidelines for Interconnection of Electric Energy Storage with the Electric Power Distribution System

Application for Operation of & Net Metering for Member-Owned Generation Name: Mailing Address: City: County: State: Zip Code: _

GUIDE FOR MICROGENERATION INTERCONNECTION TO CITY OF MEDICINE HAT ELECTRIC DISTRIBUTION SYSTEM

Hawai'i Island Planning and Operations MEASURES TO IMPROVE RELIABILITY WITH HIGH DER

Eligible Renewable Generation (ERG) Application INSTRUCTIONS

New Hampshire Electric Cooperative (NHEC) Introduction to Net Metering

Sample Application for Certificate of Public Convenience and Necessity from NC Solar Center

2018 Customer generation rates

APPLICATION Net Energy Metering Interconnection For Solar And/Or Wind Electric Generating Facilities Of 30 Kilowatts Or Less

Level 2, Level 3 & Level 4 Interconnection Request Application Form (Greater than 10 kva to 10 MVA or less)

RIDER NM NET METERING

CUSTOMER / ACCOUNT INFORMATION Electric Utility Customer Information (As shown on utility bill)

INTERCONNECTION RULES AND REGULATIONS FOR NET ENERGY METERING SYTEMS

Southern Company Interconnection Process. Dexter Lewis Research Engineer Research and Technology Management

Renewable Energy System Tariffs and Pricing

Michigan Renewable Energy Case Study

Connecting your home or small business generation

Noble County Rural Electric Membership Corporation

APPLICATION ELECTRICITY SERVICES. APPLICATION FOR THE CONNECTION OF SMALL SCALE EMBEDDED GENERATION Page 1

Codes and Standards: Focusing on the Sustainability Aspects of Electrical Installations What, Why and How?

A guide to rate information & requirements for the interconnection of a solar distributed generating system

Impact of Distributed Energy Resources on Transmission System Reliability

Renewable Energy Interconnection Manual for Small Size Systems ( 10kW in NM 20kW in TX) Renewables and Emergent Technologies Group

Puget Sound Energy Overview

Producing your own energy? Great Decision. ComEd.com/Interconnection. Let s connect you to our smart grid.

(2) Scope. 220 CMR applies to all Distribution Companies subject to the jurisdiction of the Department.

Consumer Guidelines for Electric Power Generator Installation and Interconnection

KANSAS CITY POWER AND LIGHT COMPANY P.S.C. MO. No. 7 Fourth Revised Sheet No. 39 Canceling P.S.C. MO. No. 7 Third Revised Sheet No.

Section 6. Generation Interconnection

Application for Commission Approval to Construct a Generating Station Pursuant to Public Utilities Article Section and

To complete the process for a net metering interconnection, please follow the steps below:

Interconnection Process for Generation Systems

Photovoltaics. MPI Hybrid Series

THE PUBLIC SERVICE COMMISSION OF MARYLAND

Transcription:

NET METERING ENROLLMENT APPLICATION REFERENCE GUIDE March 20, 2006 Updated September 2013

SCOPE The purpose of this Guide is to help you understand sections 2 to 9 of the Net Metering Enrollment Application. SECTION DESCRIPTIONS Section 2 Specifications of the customer s electrical installation Phases Indicate whether you have single-phase or three-phase supply. Rated voltage (A C) Enter the rated voltage of your electrical installation. The regular voltages for connection to the Hydro-Québec distribution grid are as follows: Single-phase connection 120/240 V Three-phase connection 347/600 V If your equipment s rated voltage differs from that of the grid, please specify. Maximum capacity of service panel (A C) Enter the capacity of the main circuit breaker on the service panel. If your installation includes one or more auxiliary service panels, state the capacity of the main circuit breaker. Section 3 Project Brief description of project and site Briefly describe the project, including the generating equipment and its location. Total area of buildings (m 2 ) Enter the total area (in square metres) of the buildings to be supplied. This information will enable us to estimate eligible generating capacity, especially in the case of a new building. Type of heating State the type of energy (oil, gas, electricity, etc.) used to heat the buildings. This information will enable us to estimate eligible generating capacity, especially in the case of a new building. Planned commissioning date Enter the date on which you plan to complete the project, or the current date if the facilities are ready for service. Hydro-Québec September 2013 2

Energy type To be eligible for the net metering option, you must use a renewable energy source. The eligible energy sources are as follows: Wind power Solar power Hydropower Geothermal power (for electricity generation only) Bioenergy (biogas or forest biomass) State which type of energy you will use for the project. If you plan to use more than one energy source, please state all of them. Rated capacity of the facility Enter the rated capacity, that is, the maximum power the installation can generate, indicating kilowatts (k W) or kilovoltamperes (k V A). The capacity indicated should not take your load into account. Rated capacity is the lower of these two values: Capacity of primary source (solar panels, wind turbines, hydropower turbines, etc.) Capacity of equipment used to tie into grid (generators or inverters) Rated capacity must not exceed the lower of the following two values: 50 k W (20 k W in case of single-phase installation with E.12-07 compliant connection) Estimated power required to meet your needs The capacity needed to meet your power needs can be roughly estimated using this equation: Power needed, in kilowatts, equals annual consumption, in kilowatthours, divided by the product of 8,760 hours and the utilization factor. Annual consumption Enter the amount of power you use in a year, in kilowatthours (k W h). You ll find this information on your bill. Utilization factor Enter the ratio of actual annual output to output at rated capacity for an entire year, as a percentage. The utilization factor takes into account resource availability, among other things. For a wind or solar power system, a utilization factor of 0.35 is good. An expert may provide a precise estimate of the utilization factor for a given site. Example Your home s annual consumption is 20,000 k W h. You want to install solar panels. Assuming a utilization factor of 0.35, the capacity required to meet your needs is calculated as follows: 20,000 k W h / (8,760 h 0.35 ) = 6.52 k W So the facility s rated capacity must be 6.52 k W or under. Hydro-Québec September 2013 3

Connection standard For the net metering rate option, the facility and equipment must comply with one of these Hydro-Québec standards: E.12-07, for facilities of 50 kw or under equipped with inverters certified to standards C S A C22.2, No. 107.1-01 or U L1741 E.12-05, for all other facilities If the connection complies with standard E.12-05, Hydro-Québec requires an engineer to submit a detailed connection study for approval. Please call Hydro-Québec to obtain a connection study template. Standards E.12-05 and E.12-07 can be downloaded from the Hydro-Québec Web site: www.hydroquebec.com/self-generation. Details of project Provide any particular project characteristics that are not indicated elsewhere on the form (additional protection, specific requirements, load controller to limit your power demand, etc.). Supplier Enter the name of the person or company that is supplying the generating equipment. May be an integrator who provides you with a turnkey installation. Master electrician or engineer Enter the name of the master electrician or engineer responsible for installing the generating equipment and testing the inverters. Section 4 Generating equipment Generating equipment refers to all the machinery needed to convert raw energy into alternating current. It may be solar panels, wind turbines, hydropower turbines, etc. If you plan to use more than one piece of equipment, please enter the information for each one. Manufacturer Enter the name of the person or company that made the generating equipment. Model Enter the generating equipment model. Rated capacity Enter the equipment s rated capacity, as specified by the manufacturer, indicating kilowatts (kw) or kilovoltamperes (k V A). Quantity Enter the number of each type of generating equipment installed on the site. A solar power setup, for example, may consist of several identical photovoltaic panels. Hydro-Québec September 2013 4

Section 5 Inverters Complete this section if your generating system requires inverters. If you plan to use more than one piece of equipment, please enter the information for each one. Manufacturer Enter the name of the person or company that made the inverter. Model Enter the inverter model. Ability to operate as backup power system? Some generating systems can be used as backup systems in case of a power outage. Hydro-Québec needs to know if this is the case for yours, even if you decide not to use it in this manner. Rated capacity Enter the inverter s rated capacity as specified by the manufacturer, indicating kilowatts (k W) or kilovoltamperes (k V A). Power factor at 100% of rated capacity Enter the inverter s power factor when operating at rated capacity. Power factor adjustable? Indicate whether the inverter s power factor is adjustable. Phases Indicate whether the inverter is single-phase or three-phase. Rated voltage (A C) Enter the inverter s rated A C output voltage. The rated voltages for connection to the distribution grid are as follows: Single-phase equipment 120/240 V Three-phase equipment 347/600 V If the inverter s rated voltage differs from that of the grid, you will need to install a power transformer. Specify the inverter s voltage and complete Section 8, Transformers. Maximum short-circuit current (A) This is the maximum current that the inverter can output if a fault (short-circuit) occurs on either the Hydro-Québec side or your side. Enter the maximum short-circuit current at the inverter output and state whether the current entered is a crest or effective value. Hydro-Québec September 2013 5

Certification Indicate whether the inverters you will be using are certified to the following standards: C S A C 22.2, No. 107.1-01 U L 1741 Attach proof of all certification obtained. A digital copy from the equipment manufacturer or supplier is acceptable. Firmware version at time of certification and Current firmware version (if different) The firmware has built-in protection functions, among other things. With the information in these two boxes, Hydro-Québec will be able to ensure that the firmware you specify on the form is indeed certified. Hydro-Québec must approve any change made since certification to ensure that the integrated protection will work properly. Section 6 Frequency and voltage protection Enter the frequency and voltage protection settings. Amplitude and Adjustment range Specify the amplitude for each function. If they are adjustable, give the ranges. Section 7 Operation as backup power system If there is a Hydro-Québec power outage, you can operate your installation as a backup power system if you have the right equipment. More specifically, you must be able to switch critical loads between the regular and backup power systems. A Hydro-Quebec approved switching device is required to enable disconnection from the distribution grid upon the switchover to standalone mode (Conditions of Electricity Service). Use as backup power system anticipated? Indicate whether you plan to use your generating equipment as a backup power system. Section 8 Transformers If the inverter s output voltage is not the same as the rated voltage of your service entrance, you may need to add transformers in order to connect to the Hydro-Quebec grid. Installation of power transformers anticipated? Indicate whether the generating facility comprises one or more power transformers. Hydro-Québec September 2013 6

For each transformer, provide the following information: Power (k V A) and rated primary and secondary voltage (V) Enter the rated capacity of each transformer. You ll find this information on the nameplate. Enter the transformer s primary voltage (Hydro-Québec grid) and secondary voltage (your installation). You ll find this information on the nameplate. Primary and secondary winding connection types Enter the types of winding connections. Here are some possible types: Three-phase equipment Y Y (with neutral grounding)* Single-phase equipment L N-L N* *Y Star connection; L Line; N Neutral. The transformer connections will influence the type of grounding system. At the connection point, Hydro-Québec requires an effectively grounded neutral. Section 9 Schematic diagram of planned facility Please provide a complete schematic of the facility, as follows: Single-line diagram of entire facility, including generating equipment and inverters Power transformer s winding connections, if applicable Transfer switch connection (for backup power), if applicable Coordinated by Communication avec la clientèle for Vice-présidence Réseau de distribution Ce document est également publié en français. 2014G1505A