SELERITY TECHNOLOGIES SOLUTIONS FOR YOUR SUPERCRITICAL FLUID NEEDS

Similar documents
STI OPENING THE DOORS TO TEMPERATURE PROGRAMMING- A NEW FRONTIER IN HIGH PERFORMANCE LIQUID CHROMATOGRAPHY

Increased sensitivity and reproducibility in the analysis of trace fatty acid methyl esters in jet fuel

Using a New Gas Phase Micro-Fluidic Deans Switch for the 2-D GC Analysis of Trace Methanol in Crude Oil by ASTM Method D7059 Application

Refinery Gas. Analysis by Gas Chromatography WASSON - ECE INSTRUMENTATION. Engineered Solutions, Guaranteed Results.

High Temperature Simulated Distillation Performance Using the Agilent 8890 Gas Chromatograph

Gas Chromatographic Analysis of Diesel Fuel Dilution for In-Service Motor Oil Using ASTM Method D7593

Technical Procedure for Gas Chromatography (GC-FID)

Model 8610C Gas Chromatograph. GC Chassis Types ECD PID FID / DELCD FPD. Mounts up to Six Detectors and Five Injectors

Alternative Carrier Gases for ASTM D7213 Simulated Distillation Analysis

Using the PSD for Backflushing on the Agilent 8890 GC System

Setting up SilFlow for BackFlush in your GC

Beverage Grade Carbon Dioxide

Optimized Supercritical Fluid Chromatographic Instrumentation for the Analysis of Petroleum Fractions

ASTM D2887 Simulated Distillation Calibration Mixture Analysis Using a Differential Acceleration Column

Application Note. Authors. Abstract. Energy & Chemicals

Application. Gas Chromatography June 1995

Impact of GC Parameters on The Separation Part 2: Choice of Column Internal Diameter

Simulated Distillation Analyzers, Software, Standards, Consumables, Training

Technical Procedure for Gas Chromatography-Mass Spectrometry (GC-MS)

GC Method Compliance and Large Valve Oven Application

Dual Plasma Sulfur and Nitrogen Chemiluminescence Detectors. Unsurpassed Stability, Selectivity, and Sensitivity for your GC Analysis

PRODUCT SPECIFICATION. Product Specification Crystal 9000 Gas Chromatograph. Chromatec Crystal Laboratory Gas Chromatography System

Antek Gas Chromatography Products: A Guided Tour Through Industry

Achieving Higher Sensitivities Using GC-FID with the Agilent Multimode Inlet (MMI)

Restek Corporation 110 Benner Circle, Bellefonte, Pa Barry L. Burger, Neil Johansen, Valerie Gamble, Donald Rhoades

SFC-FID ASTM System. SFC-4000 Series SFC. Performance Innovation Reliability

Determination of Free and Total Glycerin in B100 Biodiesel

AA SOLUTIONS Manufacturer

Agilent and ASTM. Update on Recent Activities. Page 1

Free and Total Glycerol in B100 Biodiesel by Gas Chromatography According to Methods EN and ASTM D6584

The Analysis of Hydrocarbon Composition in LPG by Gas Chromatography using the DVLS Liquefied Gas Injector

White Paper. Improving Accuracy and Precision in Crude Oil Boiling Point Distribution Analysis. Introduction. Background Information

Achieving Lower Detection Limits Easily with the Agilent Multimode Inlet (MMI)

GC/MS Analysis of Trace Fatty Acid Methyl Esters (FAME) in Jet Fuel Using Energy Institute Method IP585

Methanol in Biodiesel by EN14110 with the HT3 and Versa Automated Headspace Analyzers. Versa HT3. Application Note. Abstract.

Liquefied Gas Injector. Solution for the Sampling and Analysis of Liquefied Gases

Performing ASTM 6584 free and total glycerin in BioDiesel using an SRI Gas Chromatograph and PeakSimple software

Analysis of Fatty Acid Methyl Esters (FAMES), and Examination of Biodiesel Samples for these Components, by GCxGC-FID

Fast Simulated Distillation Based on Agilent 6890N Gas Chromatograph Application

Agilent 7696A Sample Prep WorkBench Automated Sample Preparation for the GC Analysis of Biodiesel Using Method EN14105:2011

Detection of Sulfur Compounds in Natural Gas According to ASTM D5504 with an Agilent Dual Plasma Sulfur Chemiluminescence Detector

Oxygenates in Fuels Analysis Solutions From Trace Levels to Ethanol Fuels

Application Note. Determination of Oxygenates in C2, C3, C4 and C5 hydrocarbon Matrices according ASTM D using AC OXYTRACER

Meeting the Requirements of EN12916:2006 (IP391/07) Using Agilent 1200 Series HPLC Systems

Agilent 7693A Automated Liquid Sampler

Optimizing Ultra Fast Simulated Distillation with a Low Thermal Mass (LTM) GC System. Jim McCurry Roger Firor Agilent Technologies Wilmington, DE

Analysis of Glycerin and Glycerides in Biodiesel (B100) Using ASTM D6584 and EN Application. Author. Abstract. Introduction

MET-Biodiesel Capillary GC Columns

Optimized Method for Analysis of Commercial and Prepared Biodiesel using UltraPerformance Convergence Chromatography (UPC 2 )

SPECIFICATION. Bench top triple quadrupole Mass Spectrometry System coupled to a gas performance Chromatography (GC-MS/MS)

Agilent 7693A Automated Liquid Sampler

GC Analysis of Total Fatty Acid Methyl Esters (FAME) and Methyl Linolenate in Biodiesel Using the Revised EN14103:2011 Method

CERTIFICATE OF ACCREDITATION

Technical Procedure for the Examination of Arson Evidence

breakthrough versatility

GAS CHROMATOGRAPHY: INJECTION TECHNIQUES CAPILLARY COLUMNS

High-Temperature Simulated Distillation System Based on the 6890N GC Application

Page 1. Alternate Carrier Gas Considerations and Faster GC Analysis

Instrument Accessories & Parts, Tubing & Connections

Agilent Multimode Inlet for Gas Chromatography

VERITY Purification Systems Build the perfect system to fit your research

Detailed Hydrocarbon Analysis Featuring Rtx -1 PONA Columns

ASTM D 6730 Detailed Hydrocarbon Analysis

Analysis of Petroleum Fractions by ASTM D2887

[ APPLICATION NOTE ] INTRODUCTION APPLICATION BENEFITS WATERS SOLUTIONS KEYWORDS

Determination of Sudan Dyes I IV in Curry Paste

Alliance HPLC DEFINED BY DEPENDABILITY, TODAY AND IN THE FUTURE

Application Note. Author. Introduction. Energy and Fuels

Determination of Free and Total Glycerin in Pure Biodiesel (B100) by GC in Compliance with EN 14105

For more information about Agilent Technologies services please visit our web site using the following URL

DETECTORS Photo Ionization Detector - PID. Overview

Analyte Focusing in Elevated Temperature HPLC

High Throughput Mineral Oil Analysis (Hydrocarbon Oil Index) by GC-FID Using the Agilent Low Thermal Mass (LTM) System

Ultrafast GC Performance in the Real World: Multi Lab Studies for Repeatability & Reproducibility

GC Injector Liners. Bruker Varian Agilent (HP) Perkin Elmer Finnigan. Phone: Page 4

Analytical and Testing Instruments for the HPI Market Shimadzu s Total Solutions for the Hydrocarbon Processing Industry

Application Note. Abstract. Authors. Environmental Analysis

Analysis and. Separation of Oxygenates in Hydrocarbon Matrices. Simon Jones Application Engineer Folsom, CA

HT8: THE PERFECT PCB COLUMN

Method Detection Limits for EPA Method 8015 Diesel Range Organics using Fully Automated Extraction and Concentration

DETERMINATION OF N-BUTANOL AND ISOBUTANOL IN GASOLINE USING GAS CHROMATOGRAPHY (GC-FID)

High-Performing Restek PAL SPME Fibers

Chromatography. Liquid. HPLC Accessories SupelPRO Valves SUPELCO

mono-layer ACR High purity Reinforced 1-10 Excellent Fair mono-layer DD High purity Reinforced Excellent Excellent

Practical Steps in GC Troubleshooting

DANI Transformer Oil Gas Analyzer

GC-101. Testing of Biodiesel Using Gas Chromatography. by Bob Armantrout. Presented at: Local Biodiesel: A Biodiesel Coop Conference

Customer Information. Service Engineer s Responsibilities. Additional Instruction Notes GC Preventive Maintenance Checklist Standard

Ultra High Performance Fittings. Fittings Connectors Kits

C2, C3, C4 Monomer Analysis

AZ Chrom s.r.o.

a review of analytical methods for the quantification of aromatics in diesel fuels

TECHNICAL REPORT. Introduction. Agilent 1100 HPLC system. Figure 1: HALO columns exhibit UHPLC-like performance at conventional HPLC pressure

Agilent Multimode Inlet

Optimized Method Development of Large Volume Injection for GC/MS/MS of Food Pesticides

AppNote 6/2006. Ultra-Fast Determination of the Hydrocarbon Oil Index by Gas Chromatography using a Modular Accelerated Column Heater (MACH) KEYWORDS

GC Inlets. An Overview. Simon Jones GC Applications Engineer

Set Your Sights on Superior Performance

performance productivity reliability

S-PRO 3200 GC System for Sulfur Analysis

Transcription:

Rev 1 3/6/2004 Selerity Technologies Inc. www.selerity.com SELERITY TECHNOLOGIES SOLUTIONS FOR YOUR SUPERCRITICAL FLUID NEEDS What is supercritical fluid chromatography? A chromatographic technique in which the mobile phase is neither a gas nor a liquid, but has properties of both: formally a supercritical fluid. At pressures and temperatures above its critical point, a gas becomes a supercritical fluid and it possesses densities and other properties that are intermediate between those of gases and liquids. When should you use Supercritical fluid chromatography? SFC offers distinct advantages over gas chromatography (GC) and liquid chromatography (HPLC) when: Compounds are not volatile enough for GC without derivatization. Compounds do not have chromophores suitable for UV detection under HPLC conditions. Compounds are unstable at typical GC temperatures. Universal detectors such as the flame ionization detector (FID) are desired that are not available for HPLC. How can you apply Supercritical fluid chromatography in your laboratory? SFC finds applications essentially wherever chromatographic techniques are used. You can now complete your laboratory with the Series 4000. Just a few of the applications possible with SFC includes: Petroleum ASTM D5186 Testing Method (aromatics and polyaromatics in diesel and jet fuels) ASTM D6550 Testing Method (olefins in gasoline) Heavy petroleum compounds and residues Petrochemicals Thermally unstable compounds, e.g., isocyanates α-acids Pharmaceuticals Thermally unstable compounds Polymers such as PEG s and polyalcohols Foods Fatty acids Natural products Surfactants (non-ionic) Polymers Light polymers (<5,000 to at most 10,000 amu) Polymer additives (especially where GC or HPLC require derivatization) Electronic Industry Polyfluorocarbons

FULLY INTEGRATED SERIES 4000 SUPERCRITICAL FLUID CHROMATOGRAPH RUGGED, RELIABLE, REPRODUCIBLE, AND EASY TO USE Fully integrated software that controls pump, oven, autosampler, and data acquisition package Temperature-controlled pressure transducer for better reproducibility 10 ml syringe pump for pulse-free pressure-controlled flow and minimal CO 2 usage Innovative column technology to suit all of your application requirements Large capacity oven suitable for any column configuration A secondary independent column heater to improve peak shape and decrease analysis times Low dead volume injections and column switching with Secure Fit column connectors Simplified split/splitless injection for capillary columns Rev 1 3/6/2004 Selerity Technologies Inc. www.selerity.com

Rev 1 3/6/2004 Selerity Technologies Inc. www.selerity.com THE SERIES 4000 SYRINGE PUMP PROVIDES ESSENTIALLY PULSE-FREE, PRESSURE-CONTROLLED FLOW The temperature-controlled pressure transducer is an exclusive design to Selerity Technologies. This design feature assures that the retention times are reproducible run after run, independent of changes in the laboratory temperature environment. Electronic cooling of the pump head assures maximum fills and accurate deliveries. Cooling the carbon dioxide also provides better pump control by decreasing compressibility of the fluid at temperatures near 0 C. Small 10-mL syringe means less torque stress for longer pump life. Automatic refill after every run guarantees you will have a full syringe for every analysis. Simple pump design with few moving parts means less downtime. The seals used in the Series 4000 SFC have demonstrated long lifetime resulting in low maintenance. Automatic shutdown when sensing low carbon dioxide pressure. The series 4000 will automatically stop when the limit switch is reached and triggers the pump to the default fill position. Consequently, pump burnout is eliminated. Delivers volumes sufficient for packed (1 mm ID) and capillary column analyses.

LARGE CAPACITY OVEN SUITABLE FOR ANY COLUMN CONFIGURATION Stable oven provides accurate heating zones for both packed and capillary column operation. Large capacity for any anticipated column type used with SFC. Flame ionization detector is standard on the Series 4000. This general purpose, universal detector is stable to flow from capillary through 1-mm packed columns. Helium actuated valves for the fastest possible switching, giving you crisp, low dead volume injections and better confidence in your data. Because of its lower molecular weight and viscosity, helium provides actuation speeds approximately four times faster than possible using nitrogen or electronic driven actuation. Rev 1 3/6/2004 Selerity Technologies Inc. www.selerity.com

AN EASY-TO-USE SOFTWARE PACKAGE THAT TAKES CONTROL OF YOUR ANALYSIS Series 4000 system offers an operating software package which provides a smooth, seamless operation between pump, oven, autosampler and data collection. All method parameters are conveniently built into the analysis method from the computer keyboard. A sequence containing a series of different analysis methods can be set up and run by simply building and starting the sequence run. All method parameters will change according to the method commands. Rev 1 3/6/2004 Selerity Technologies Inc. www.selerity.com

INDEPENDENT COLUMN HEATER, ESPECIALLY USEFUL WHEN TWO DIFFERENT COLUMN TEMPERATURES ARE DESIRED Optional secondary column heater with independent temperature control. Custom design for column switching techniques used for petroleum analysis. The secondary column heater conveniently mounts to the wall of the oven cavity. ASTM D6550 testing method is improved The oven cavity is maintained at a lower temperature to optimize the separation of saturates and aromatics, while the silver-loaded silica column can be maintained at up to 200 C to optimize the interactions between the olefinic compounds and the silver ions. Olefin peak shape is greatly improved and the sensitivity is increased. Tailing on the olefin peak ascibed to overly strong olefin interaction with the silver ions is significantly reduced when the silver loaded column is heated. Rev 1 3/6/2004 Selerity Technologies Inc. www.selerity.com

SPLIT/SPLITLESS INJECTION TECHNIQUE FOR CAPILLARY COLUMN ANALYSIS SUPERCRITICAL FLUID CHROMATOGRAPHY IS NOW SIMPLE AND REPEATABLE Directly injects the sample onto the column while eliminating the effects of dead volume. Higher loadability of analytes on capillary columns for greater sensitivity and better precision. Decreases solvent effects of early eluting peaks and improves the peak shape of all analytes in your sample. Separates volatile analytes from the solvent. Increased sensitivity allows resolution of compounds with a much higher molecular weight than heretofore possible. Rev 1 3/6/2004 Selerity Technologies Inc. www.selerity.com

SELERITY TECHNOLOGIES SECRET TO GREAT CHROMATOGRAPHY IS ITS UNIQUE COLUMN TECHNOLOGY In-house column technology allows Selerity Technologies to achieve specialized and optimal SFC applications. Manufacture high performance 1 mm packed columns for SFC that are conditioned and cleaned with supercritical carbon dioxide for immediate use. All packed column housings are specially treated for efficient packing and allow the use of Secure-Fit column connectors. Manufacture high performance 50mm capillary columns for SFC. All capillary columns are based on polysiloxane bonding chemistry. All columns are individually tested by SFC to guarantee superb column performance and are ready to use upon installation. SFC Packed Columns Silica Silver-loaded silica Polyvinyl alcohol (PVA) C18 Diol Fluorocarbon SFC Superbond (SB) Capillary Columns SB-Methyl-100 SB-Phenyl-5 SB-Biphenyl-30 SB-Cyano-25 SB-Cyano-50 SB-Phenyl-50 SB-Octyl-50 Rev 1 3/6/2004 Selerity Technologies Inc. www.selerity.com

ELIMINATE THE DEAD VOLUME CURSE WITH THE SELERITY TECHNOLOGIES PATENTED SECURE-FIT COLUMN CONNECTOR Significantly improve chromatographic performance. Zero dead-volume connections obtained by applying finger-tight tension. Self-adjusting within any depth and any type of acceptor fitting. The spring tension automatically positions the end of the tubing against the inside fitting face. Finger-tight tension, no wrenches needed. Holds to pressures up to 10,000 psi. U.S. Patent 6,193,286. 1 2 1 3 1 Silver soldered stainless steel washers 2 Stainless steel spring 3 Polymeric Ferrule Reference Technical Note 101 Rev 1 3/6/2004 Selerity Technologies Inc. www.selerity.com