Multi-function. Mono-function 1 NO (SPST-NO)

Similar documents
functions: --Staircase timer --Staircase timer + maintenance function --Staircase timer with early warning

xxx.1xx xxx.4xx0. AgNi contacts, specifically intended for resistive and slightly inductive loads as well as for motor loads

Time scale: from 0.05s to 100h Multi-function Plug-in for use with 90.02, 90.03, and sockets

MasterINTERFACE 39 Series - Relay interface modules

Time scale: from 0.05 s to 100 h Multi-function Plug-in for use with 96 series sockets. Relay + socket. Wiring diagram (without control signal)

55 Series - Miniature General Purpose Relays 5-10 A

CO (DPDT) 16/25 250/ /440 2,000 4, /0.5/ /0.5/ (5/5) 300 (5/5) AgNi

2 pole 10 A PCB mount A1 A

2 pole, 10 A AC/DC supply non polarized Plug-in for use with 94 series sockets

40 Series - Miniature PCB relays A. Features

0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N

5 mm contact pin pitch PCB or 95 series sockets

46 and 56 Series - Relays for railway applications 8-12 A. Features 46.52T 56.32T 56.34T

60 Series - General purpose relays 6-10 A. Features SERIES

2 pole, 10 A power contacts 8 pin plug-in CO (DPDT) 3 CO (3PDT) Rated current/maximum peak current

Slim P.C.B. Relays (EMR or SSR) A

Installation Contactors RIC, RAC

Command and signalling E 250, E 259 selection table

General purpose relays 7-10 A

General purpose relays 6-10 A

Miniature Industrial relay 8-16 A

RY2L Series Miniature Magnetic Latching Relays. E Release Time. 60N (0 6G); Maximum frequency 55Hz

YS Series Contactors YS1N- F11 ****

System 2000 DRA automatic stairway lighting, Impulse insert. 1 Safety instructions. 2 Device components

Locking Style mm AUTOCAD, STEP, IGES & PDF. Kits Actuator Type Interlock Kit Model * Contact(s) SI-LS42DMSG SI-LS42WMSG

Signaling solutions. Monolithic indicator banks Harmony type XVC. Dimensions: page 12

Modular contactor for installation into distribution boards

NRBM Series. Between main circuit terminals: 2,000V AC, 1 minute Between main circuit and auxiliary contact: 2,000V AC, 1 minute

RUC industrial relays of small dimensions

Thermal-Magnetic Circuit Breaker 201/-WA

44 SERIES. PCB/Plug-in relays from 6 to 10 A

TURCK Inductive Sensors - Rectangular

W Datasheet: DIN Rail Contactors, series AMPARO

SERIES SINGLE AND DOUBLE-POLE PUSHBUTTON SWITCHES

Brushless DC Axial Fans

Emergency lighting units EM powerled

Sealed Pushbutton Switches

Emergency lighting units EM converterled. EM converterled ST 50 V SELFTEST series

Series. Able to control the stroke with only ON/OFF signals. Directional control driver like a solenoid valve. Able to set thrust arbitrarily.

High Performance Thermal-Magnetic Circuit Breakers 410/520/

CI-TI Contactors and Motor Starters Type CI 6-50

RE48AML12MW time delay relay 2 functions s..300 h V AC - 2 OC

Emergency lighting units EM powerled

Latch for Contactors 4-pole see page 36. Ratings Rated Aux. Contacts Type Coil voltage 2) AC2 Current Built-in Additional 24 24V= DC 5

Defining a timer in simple terms. Which actions are executed? Which market are they used frequently? Benefits and Advantages

Contact data Number and type of contacts Contact material Rated / max. switching voltage Min. switching voltage

2/3 Port Mechanical Valve. Specifications Fluid Operating pressure Ambient and fluid temperature Effective area Lubrication Port size Mass (Basic)

Emergency lighting units EM converterled. EM converterled PRO 200 V PRO series

Modular Contactors and Switches D681E121

CI-TI Contactors and motor starters Types CI 61 - CI 98

Emergency lighting units EM converterled. EM converterled ST 90 V SELFTEST series

MODULAR DEVICES. 21. Isolator Switches. Low Voltage (Bell) Transformers. Time Switches (electromechanical)

NRA Series. Between main circuit terminals: 2,000V AC, 1 minute Between main circuit and auxiliary contact: 2,000V AC, 1 minute

Emergency lighting units EM Inverter

Emergency lighting units EM INVERTER

Data sheet TERMSERIES TRZ 120VUC 1CO

Scheda prodotto Relè Series E

Section. Circuit Breakers Selection Guide...N-2. NRA Series...N-3. NRBM Series...N-13. NRC Series...

Door Interlock Switches

SERIES SINGLE AND DOUBLE-POLE ROCKER SWITCHES

Industrial Contactors CTX 3 3P 185A - 800A

Emergency lighting units EM powerled

Circuit Breakers. Switching & Controls. Selection Guide NC1V Series Dimensions Accessories

Emergency lighting units EM converterled. EM converterled PRO 50 V PRO series

Safety Relay Unit. Ordering Information. Ideal for Safety Door and Emergency Stop Switch Circuits for Machines in European Countries

Emergency lighting units EM powerled. EM powerled BASIC CLE Emergency lighting LED Driver

General_technical_data Series

PO Box 2484 Rowville Vic 3178

Application Support. Product Information. Omron STI. Support Engineers are available at our USA headquarters from

Diameter (mm) Sinking. Sourcing. Drawing # Wiring Diagram # of LEDs. Bi10NF-M30-AN6X A M

Emergency lighting units EM powerled

Emergency lighting units EM powerled

Emergency lighting units EM powerled

Installation Relays. Power Relays Step-on Step-off Relays Staircase Lighting Timers Power Step-on Step-off Relays Installation Contactors 103 KAT

Miniature Circuit-Breakers (MCBs)

Circuit Breakers. Switching & Controls. Selection Guide NC1V Series Dimensions...

Oiltight Switches & Pilot Devices

Compact Sheet-steel Emergency Light Fitting Series 6118/1

90 Series - Socket overview for 60 series relays

TURCK DC Insertion Flow Monitors

System pro M compact Miniature Circuit Breaker SU200M for branch circuit protection acc. to UL 489

Type Contact form Enclosure ratings Model Standard SPST-NO (Class A) Flux protection G5LA-1A Sealed

Pneumatic Timer. TECHNICAL DATA Display digit roll s, s or s, depending on version Operating pressure 2...

Electropneumatic Timing Relays Series 7000 Industrial

B Mini Contactor V Hz

AE 9... AE 40 Contactors NE... Contactor Relays

4 - Miniature controls

CI-TI TM Contactors and Motor Starters Contactors CI 6-50

Clarian uk ltd SWITCHES AND CONTROLS TOP-TECHNIC TOP-TECHNIC TOP-TECHNIC TOP-TECHNIC TOP-TECHNIC TOP-TECHNIC.

TeSys contactors. Use in category DC-1 (resistive loads; time constant L/R y 1 ms) Rated operational current Ie. to be wired in series

Approved Standards. Motor Contactor. Main contactor. Accessoires. 21 Motor Contactor J7KN

SA1W: Water Detection Sensors

Timer Relays - Fixed & Adjustable

Cat N 3. OVERALL DIMENSIONS

ABB i-bus KNX Room Master, MDRC RM/S 4.1, 2CDG R0011

Flow Switch Paddle Style Flow Switch. How to Order IF3 1 1 N Paddle style flow switch. Dripproof/Rainproof type (Equivalent to IP42)

G9SA-TH. Two-Hand Controller. Ordering Information. Specifications. 45-mm Wide Two-hand Control Circuit. H Two-hand Controller, easy-to-connect

I r A short-circuit protective device: Observe the maximum permissible fuse of the contactor with direct device mounting.

AF40... AF96 3-pole contactors Technical data

Contactors. d 3-pole contactors for motor control, 9 to 95 A Utilisation category AC-3 Control circuit : a.c. References

Transcription:

Features Range of electronic staircase timers 17.5 mm wide Time setting from 30 s to 20 min Zero crossing load switching Switch-off early warning - model 14.01 Suitable for 3 or 4 wire systems, with automatic recognition (14.01 and 14.71) or via pushbutton configuration (14.81) ED status indicators (14.01 and 14.71) Cadmium free contact material Can be used with illuminated push - buttons Blade + cross - both flat blade and cross head screw drivers can be used to adjust the function selector, the timing trimmer, and to disengage the 35 mm rail mounting clip 14.01 14.71 Multi-function Mono-function 1 O (SPST-O) 1 O (SPST-O) 35 mm rail (E 60715) mount 35 mm rail (E 60715) mount Contact specification Contact configuration Rated current/maximum peak current A Rated voltage/maximum switching voltage V AC Rated load AC1 Rated load AC15 (230 V AC) ominal lamp rating:incandescent (230 V) W compensated fluorescent (230 V) W uncompensated fluorescent (230 V) W halogen (230 V) W Minimum switching load mw (V/mA) Standard contact material Supply specification ominal voltage (U ) V AC (50/60 Hz) V DC Rated power (50 Hz)/W Operating range AC (50 Hz) DC Technical data Electrical life at rated load in AC1 cycles Delay setting min Max no. of illuminated push-button ( 1 ma) Maximum impulse duration Ambient temperature range C Protection category Approvals (according to type) 1 O (SPST-O) 1 O (SPST-O) 16/30 (120 A - 5 ms) 16/30 (120 A - 5 ms) 230/ 230/ 3,700 3,700 750 750 1,000 (10/10) 1,000 (10/10) AgSnO 2 AgSnO 2 230 230 3/1.2 3/1.2 (0.8 1.1)U (0.8 1.1)U 100 10 3 100 10 3 30 30 IP 20 IP 20 1 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside ocal Area: (800) 258-9200-www.stevenengineering.com

Features Range of electronic staircase timers 17.5 mm wide Time setting from 30 s to 20 min Zero crossing load switching Types 14.81 and 14.91: wiring compatible with mechanical versions and with old type (low emission) illuminated pushbuttons Suitable for 3 or 4 wire systems, with automatic recognition (14.01 and 14.71) or via pushbutton configuration (14.81) Cadmium free contact material Can be used with illuminated push - buttons Blade + cross - both flat blade and cross head screw drivers can be used to adjust the function selector, the timing trimmer, and to disengage the 35 mm rail mounting clip 14.81 14.91 Mono-function 1 O (SPST-O) 35 mm rail (E 60715) mount All terminals on same side Mono-function 1 O (SPST-O) 35 mm rail (E 60715) mount 3 terminals, on same side Contact specification Contact configuration Rated current/maximum peak current A Rated voltage/maximum switching voltage V AC Rated load AC1 Rated load AC15 (230 V AC) ominal lamp rating:incandescent (230 V) W compensated fluorescent (230 V) W uncompensated fluorescent (230 V) W halogen (230 V) W Minimum switching load mw (V/mA) Standard contact material Supply specification ominal voltage (U ) V AC (50/60 Hz) V DC Rated power (50 Hz)/W Operating range AC (50 Hz) DC Technical data Electrical life at rated load in AC1 cycles Delay setting min Max no. of illuminated push-button ( 1 ma) Maximum impulse duration Ambient temperature range C Protection category Approvals (according to type) 1 O (SPST-O) 1 O (SPST-O) 16/30 (120 A - 5 ms) 16/30 (120 A - 5 ms) 230/ 230/ 3,700 3,700 750 750 1,000 (10/10) 1,000 (10/10) AgSnO 2 AgSnO 2 230 230 3/1.2 3/1.2 (0.8 1.1)U (0.8 1.1)U 100 10 3 100 10 3 25 25 IP 20 IP 20 2 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside ocal Area: (800) 258-9200-www.stevenengineering.com

Ordering information Example: 14 series multi-function relay, single phase switch 1 O (SPDT-O) 16 A contact, supply rated at 230 V AC. 1 4. 0 1. 8. 2 3 0. 0 0 0 0 Series Type 0 = 35 mm rail (E 60715) mount, multi-function 7 = 35 mm rail (E 60715) mount, mono-function 8 = 35 mm rail (E 60715) mount mono-function, all terminals on same side 9 = 35 mm rail (E 60715) mount, mono-function, 3 terminals o. of poles 1 = Single phase switch, 16 A Supply voltage 230 = 230 V Supply version 8 = AC (50/60 Hz) Technical data Insulation Dielectric strength between open contacts V AC 1,000 Other data Power lost to the environment without contact current W 1.2 with rated current W 2 Maximum cable length for push-button connection m 200 Screw torque m 0.8 Max. wire size solid cable stranded cable mm 2 1x6 / 2x4 1x4 / 2x2.5 AWG 1x10 / 2x12 1x12 / 2x14 Zero crossing switching 1. ower inrush current protects and increases lamp life 2. ower inrush current reduces the possibility of contact welding 3. The current at switch-off is also lower, reducing stress and wear on the contacts ote Using the type 14.91, the lamps are switch on direct by the pushbuttom Accessories Adaptor for panel mounting, 17.5 mm wide 020.01 020.01 Sheet of marker tags, plastic, 72 tags, 6x12 mm 060.72 060.72 3 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside ocal Area: (800) 258-9200-www.stevenengineering.com

Wiring diagrams Type 14.01 14.71 Red ED indication: Continuous = relay O Blinking = relay OFF 3 wire connection 4 wire connection Type 14.81 (pushbutton configuration required as per the Installation manual) 3 wire connection 4 wire connection Type 14.91 (the push-buttons must be rated for the load current) 4 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside ocal Area: (800) 258-9200-www.stevenengineering.com

Wiring diagrams Possibility of connection of 14.01 with PIR movement detectors (18 series) 14 Series - Electronic staircase timer 16 A 3 wire connection (with 18.21.8.230.0300 or 18.31.8.230.0300 only) 4 wire connection (with 18.01.8.230.0000, 18.11.8.230.0000, 18.21.8.230.0300 or 18.31.8.230.0300) 18.21/18.31 14.01 14.01 18.21/18.31 18.01/18.11 14.01 Functions Type 14.01 Functions selectable with front rotary selector (BE) Staircase relay duration; subsequent impulses during the timing period will extend the timing period by the full pre-set value. On expiry of the time delay, the output contact opens. (BP) Staircase relay with early warning On initial impulse the output contact closes and the timing starts for the pre-set duration. After the timing period, the output contact blinks off once; 10secs later the contact blinks off twice, and after a further 10secs the contact opens. During the pre-set and 20 second warning time, it is possible, by a further impulse, to extend the time by the full pre-set value. (IT) Timing step relay duration; On expiry of the time delay, the output contact opens. During the timing period it is possible to immediately open the contact with a further impulse. (IP) Timing step relay with early warning duration; After the timing period, the output contact blinks off once; 10 secs later the contact blinks off twice, and after a further 10 secs the contact opens. During the pre-set and 20 second warning time, it is possible to immediately open the output contact by a further impulse. (RI) Step relay After every impulse, the output contact changes state - alternately switching from open to closed and vice versa. ight O With this function set - the output contact stays permanently closed. OTE: The blinking within the Early Warning functions (BP and IP) could cause re-start problems for fluorescent lamps with electromagnetic chokes (both conventional and compact types); We consequently suggest not to use such lamps with these functions. 5 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside ocal Area: (800) 258-9200-www.stevenengineering.com

Functions Type 14.71 Functions selectable with front selector Staircase relay duration; subsequent impulses during the timing period will extend the timing period by the full pre-set value. On expiry of the time delay, the output contact opens. Staircase maintenance function An impulse of 5 seconds will close the output contact for 60 minutes, after which time the contact will open. Ideal for maintenance or cleaning activities. The 60' timing can be interrupted by a further impulse of 5 seconds, the output contact opens. ight O With this function set - the output contact stays permanently closed. Type 14.81 Staircase relay duration; subsequent impulses during the timing period will extend the timing period by the full pre-set value. On expiry of the time delay, the output contact opens. Staircase maintenance function An impulse of 5 seconds will close the output contact for 60 minutes, after which time the contact will open. Ideal for maintenance or cleaning activities. The 60' timing can be interrupted by a further impulse of 5 seconds, which will re-establish the staircase timer function; so on expiry of the staircase time delay, the output contact opens. Type 14.91 Signal O pulse On initial impulse the output contact closes, and remain so for the duration of the preset delay. On expiry of the time delay, the output contact opens. 6 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside ocal Area: (800) 258-9200-www.stevenengineering.com