Owners Installation, Operation, and Safety Manual

Similar documents
Remote Dispensing Cabinet 902V Series Cabinet Dispenser

FR310V Parts List WARNING! DO NOT

Owners Installation, Operation, and Safety Manual. Series 300V. Fuel Transfer Pump. Series 300V 115 and 230 VOLT AC

FR1200G / FR2400G / FR4200G / FR4400G SD1200G / Series DC Transfer Pumps

FR600G Series AC Transfer Pumps

SERIES 300V 115 and 230 VOLT AC FUEL TRANSFER PUMP Owner's Operation & Safety Manual Models FR300V, FR301V, FR310V & FR311V

Digital Liquid Meter

M-3025CB-AV Fuel Pump

PRO PRO20-115RD 115-Volt AC. PRO Volt AC OWNER'S MANUAL SAVE THESE INSTRUCTIONS

DC 12V 8GPM Fuel Transfer Pump Kit User s Manual

M-1115S Series Fuel Pump

Electric Vehicle Charging Station

M-150S Series 12-Volt Fuel Pump M-150S-B100-MU Manual Nozzle & M-150S-B100-AU Automatic Nozzle Owner s Manual

Model DEF Pump Diesel Exhaust Fluid Transfer Pump

Owner s Operation and Safety Manual High Flow DC Powered Fuel Transfer Pump

Electric Fuel Pump FPM

CM-3120 (115-volt, NPT, Gallon or Litre) CM-3220 (230-volt, NPT, Gallon) CM-3260 (230-volt, BSPT, Litre) Heavy Duty Cabinet Model Fuel Transfer System

Owner's Operation & Safety Manual SERIES 800C METER. For models 806C, 807C OUTSTANDING FEATURES

Owner s Installation and Operation Manual 8 GPM DEF Pump

SERIES FR400 DIAPHRAGM PUMP

INSTALLATION GUIDE AND USER MANUAL

MECHANICAL FUEL METER. FM-100 and FM-200 Series Owner s Manual

305 REMOTE DISPENSER

INSTALLATION GUIDE AND USER MANUAL

INSTALLATION & MAINTENANCE MANUAL

IMPORTANT INFORMATION

INSTALLATION MANUAL ELECTRIC DOUBLE OVEN RANGE

MR 5-30 or MR 5-30N Series Fuel Meter Owner s Manual

INSTALLATION INSTRUCTIONS FOR FACTORY MUTUAL APPROVED INSTRUMENTS

G8 Portable Fuel Transfer Pump Owner s Manual

ILLUSTRATED PARTS LIST

STOP. M-3130 & M-3130-RDP Series. 115/230 Volt Super Duty Fuel Pumps. Owner s Manual. M-3130-PO Pump Only DO NOT RETURN THIS PRODUCT TO THE STORE!

MODEL NUMBER: MEDIUM DUTY ONBOARD AIR SYSTEM

OWNER'S MANUAL SAVE THESE INSTRUCTIONS

OWNER S MANUAL SELF-PRIMING PORTABLE UTILITY PUMP

SOS SERIES SOS1 SOS2. Spares On Site Battery Cabinet Installation Guide rEV3

M-3130 & M-3130-RDP Series 115/230 Volt Super Duty Fuel Pump M-3130-ML Manual Nozzle M-3130-AL Automatic Nozzle M-3130-PO Pump Only Owner s Manual

OPERATOR S MANUAL C INCLUDING: OPERATION, INSTALLATION & MAINTENANCE RELEASED:

Easy/Tran TF STANDBY POWER FURNACE SWITCH TOOLS NEEDED FOR INSTALLATION. PARTS LIST for Easy / Tran TF FURNACE TRANSFER SWITCH

Electric Fuel Pump FPM

DSTP20: Fuel Transfer Pump

model ps600 Address all communications and shipments to: FEDERAL SIGNAL CORPORATION

Vapor Recovery Assist System

DIESEL EXHAUST FLUID PUMP MOTOR ASSEMBLY REPLACEMENT GUIDE

FM-530-RD Remote Dispenser

Charcoal Filter Installation NOTE: The charcoal filters are preinstalled if you purchased the range hood with re-circulating kit from us. 1. Remove st

Installation, Operation and Maintenance Manual

Model FR610C Pump Shown. Suction Pipe, 1/4 HP VAC/60 HZ Motor, and Model 807C1 Meter Installed.

HALLMARK INDUSTRIES INC

CHROME ALLEY CAT L.E.D. FUEL & BATTERY GAUGE 7381

Installation, Operation and Maintenance Manual Stancor SSD & SL Series Pumps

Installation, Operation and Maintenance Manual

STP-DHI DISPENSER HOOK ISOLATION STP-DHI 120 Volt Hook STP-DHIB 240 Volt Hook

Users Manual Professional Series Direct Drive Pump.25-2 GPM Series Safety, Operating, Installation, and Maintenance Instructions

Installation Instructions Light Commercial & Irrigation Water Pressure Booster System

MR 5-30-RD Remote Dispenser

3 Phase Smart Controller

OPERATOR S MANUAL A

Instruction Sheet. Subject: Installations Instructions. Air Compressor Kits. Importan

DC400 Dispensing Cutoff System

8300 Series Installation Guidelines

poollux Power plx-pw60 & plx-pw100

PowerLogic High Density Metering System 4-Meter Enclosure Installation Guide

SynergEX Panelboards for Hazardous Locations

MODEL SAFETY & INSTRUCTION MANUAL

Utility Distribution Systems Installation, Operation, and Maintenance Manual

DuraMAC LIGHT COMMERCIAL & IRRIGATION WATER PRESSURE BOOSTER SYSTEM INSTALLATION INSTRUCTIONS

Models- 8105, Commercial Vacuums. Product Information Product Dimensions. Important Safety Instructions

MR 5-30 Aviation Fuel Meter Owner s Manual

Wilo SP Series Submersible Utility Pumps ETT. ETT Installation and operating instructions

Oil Control Handle with Mechanical Meter. Introduction. General Information. Important Information 3575-A 3575-B 3575-C 3575-D

Model 1210C Battery Powered Pump Shown

INSTRUCTION MANUAL ELECTRIC DIESEL PUMP KIT

Operating and Installation Instructions

ESE Series Cast Iron Sewage Pumps

CM-3120 (115-volt, NPT, Gallon or Litre) CM-3220 (230-volt, NPT, Gallon) CM-3260 (230-volt, BSPT, Litre) Heavy Duty Cabinet Model Fuel Transfer System

PROFESSIONAL GRADE FUEL TRANSFER PUMPS CATALOG

Installation. Introduction

LM-200 MECHANICAL LUBE METER Owner s Manual

Installation, Operation and Maintenance Manual Stancor SE, SV, SS & SC Series Pumps

SPECIFICATIONS Horsepower: 1.5 HP Running Maximum PSI: 125 PSI Tank Capacity: 15 Gallons CFM: 6 40 PSI 5 90 PSI

PROPER ELECTRICAL CONNECTIONS

Installation & Operation Manual. IMPORTANT: This manual contains important information. READ AND KEEP FOR REFERENCE.

INSTALLATION AND OPERATING

AHFP85L-im -issue INSTRUCTION MANUAL 12V HIGH FLOW DIESEL PUMP KIT AHFP85L-12A

SERIES FR400 DIAPHRAGM PUMP

OPTEVA 378 ENHANCED CASH RECYCLER TERMINAL FRONT LOAD LOBBY UNIT PLAN VIEW FRONT VIEW SIDE VIEW

M-1115S Series Fuel Pump

Owner's Manual. Model RP Series Power-Vac

SunLink PV System Disconnect with Arc Fault Detection Installation and Operations Manual

ME217PIB / ME503PIB SMART INTERLOCK TECHNOLOGY ACME ADAPTER INTERLOCK BRACKET INSTALLATION AND OPERATING INSTRUCTIONS

Model &

INSTALLATION AND OPERATION MANUAL ARM-4073 AUTOMATIC REPRESSURE MODULES

LIQUIDYNAMICS Light Viscosity Bulk Transfer Cart

Installation Instructions for Load Management Kit A051C329

UNPACKING SAFETY GUIDELINES GENERAL SAFETY INFORMATION. Operating Instructions & Maintenance Manual

Preparation Advanced Preparations: Be familiar with the controls of the range hood by reading through Range Hood Operations, Page 12. Place the range

RollSeal 1733 County Road 68 Bremen, Alabama Part No Rev Owner s Manual RS-Divider Curtain

OWNER S MANUAL SUBMERSIBLE UTILITY PUMP

Installation and Service Instructions for 87,000 & 87,100 Series Self-Adjust Brakes (rev. B)

Transcription:

Owners Installation, Operation, and Safety Manual Remote Dispensing Cabinets Models FR102PH FR302DP FR902DP FR910PM Tuthill Corporation 8825 Aviation Drive Ft. Wayne, IN 46809 (260) 747-7529 www.tuthill.com www.fillrite.com 1

Table of Contents About This Manual... 2 Safety Information... 3 Locking... 3 Installation... 3 Mechanical Installation... 5 Electrical Installation... 5 Wiring Diagrams... 6-13 Plumbing Instructions... 14 Operating Instructions... 14 Fluid Compatibility... 16 Wetted Parts... 16 Assembly and Disassembly... 16-17 Cabinet Exterior Dimensions... 18-20 Thank You! Thank you for your purchase of the Fill-Rite Dispenser Cabinet! Your Fill-Rite product comes with over 80 years of fluid transfer experience behind it, providing you the value that comes with superior performance, user friendly design, long service life, and solid, simple engineering. Experience that gives you peace of mind. About This Manual Excellence at Work. Excellence in Life. From initial concept and design through its final production, your Fill-Rite dispenser is built to provide years of trouble free use. To ensure it provides that service, it is critical that you read this entire manual prior to attempting to install or operate your new dispenser. Become familiar with the terms and diagrams, and pay close attention to the highlighted areas with the following labels: WARNING! Emphasizes an area in which personal injury or even death could result from failure to follow instructions properly. Mechanical damage may also occur. IMPORTANT! These boxes contain information that illustrates a point that may save time or may be key to proper operation, or clarifies a step. CAUTION! Failure to observe a Caution can cause damage to the equipment. At Fill-Rite, your satisfaction with our products is paramount to us. If you have questions or need assistance with your product, please contact us at 1-800-634-2695 (M-F 8 AM 5 PM ET). Warranty information for your Fill-Rite product can be found at: www.fillrite.com 2

Safety Information WARNING! To ensure safe and proper operation of your equipment, it is critical to read and adhere to all of the following safety warnings and precautions. Improper installation or use of this product can cause serious bodily injury or death! 1) NEVER smoke near the dispenser, or use the dispenser near open flames when dispensing a flammable liquid! Fire can result! 2) A Fill-Rite filter should be used on the dispenser outlet to insure no foreign material is transferred to the fuel tank. 3) Threaded pipe joints and connections should be sealed with the appropriate sealant or sealant tape to minimize the possibility of leaks. 4) Storage tanks should be securely anchored to prevent shifting or tipping when full or empty. 5) To minimize static electricity build up, use only static wire conductive hose when dispensing flammable fluids, and keep the fill nozzle in contact with the container being filled during the filling process. 6) DO NOT exceed 50 psi/ 3.5 BAR line pressure. 7) DO NOT install a foot valve or check valve without a pressure relief valve; cracking may result. WARNING! This product must not be used to transfer fluids into any type of aircraft. Locking WARNING! This product is not suited for use with fluids intended for human consumption or fluids containing water. Your Fill-Rite pump nozzle can be locked for added security. With the pump turned off, and the nozzle in the stored position, a lock can be inserted through the nozzle rest and the nozzle handle opening. This configuration prevents the nozzle from being removed and the pump being turned on. Installation An emergency shut-off valve with fusible link must be installed at the dispenser inlet. All piping must be Schedule 40. Use UL classified gasoline and oil resistant pipe compound on all threaded joints. See page 14 and 15 for sample plumbing diagrams. IMPORTANT! Remote dispensers and tank top pumps must be installed in accordance with local, state, and national electrical code NEC/ANSI/NFPA 70, NFPA 30, NFPA 30A, and NFPA 395. 3

Additionally, the Fill-Rite Cabinet Dispensers require a safety approved pressure relief valve be incorporated into the installation, either as part of the pump or separately at the dispenser itself. To assure proper operation your dispenser cabinet must be secured to a solid mounting surface. Fill-Rite recommends installing Cabinet Dispensers on either the KITWB Mounting Bracket kit, or the KITPD pedestal. These two mounting options are designed specifically for use with the Fill-Rite Cabinet Dispensers, and feature pre-drilled openings located for plumbing, wiring, and fastening. They also include the necessary hardware to fasten the cabinet correctly and securely in place. See your Fill-Rite Distributor for more information on these mounting kits. KITWB Wall Bracket KITPD Pedestal 4

Mechanical Installation 1. Install the pump (if not included) securely to the top of the fuel tank per the instructions included with the pump. 2. Install mounting plate or pedestal as applicable for your installation. Refer to the mounting plate Tank Mounting section of the mounting plate instructions. 3. Remove the dispenser cover to allow inside access to the bottom of the dispenser (see bracket / pedestal instructions for specific screw locations). 4. Place dispenser on mounting plate or pedestal; using the 4 1/2 x 13 screws, and grommet washers, attach the dispenser securely to the mounting surface through the 4 holes located in bottom of the dispenser cabinet base (figure 1). 5. Installations must include an Emergency Shut- Off Valve (not supplied) to the dispenser inlet. Position valve so it can be rigidly mounted and is not dependent on the dispenser for support. Figure 1 6. Carefully measure and install pipe between the pump and Emergency Shut Off Valve. The pipe is not intended to support the pump or the dispenser in any manner. NOTE: Dimensional drawings for installation purposes are located on pages 18 20. CAUTION! Threaded pipe joints and connections should be sealed with the appropriate sealant or sealant tape to minimize the possibility of leaks. Electrical Installation WARNING! Overall dispenser installation and electrical wiring should be performed ONLY by a licensed electrician and service personnel in compliance with local, state, and national electrical code NEC/ANSI/NFPA 70, NFPA30, NFPA 30A, and NFPA 395 as appropriate to the intended use of the dispenser. Threaded rigid conduit, sealed fittings, and conductor seal should be used. The pump must be properly grounded. Improper installation or use of this dispenser can result in serious bodily injury, or death! CAUTION! All electrical appliances should operate at the rated nameplate voltage. Power should be supplied to this dispenser from a dedicated 20 amp circuit breaker. No other equipment should be powered by this circuit. Wiring must be of sufficient size to carry the correct current for the pump. Voltage drop will vary with distance to pump and size of wire; refer to the National Electrical Code (NEC), or local codes, for voltage drop compensation to be sure you are using the correct size wire for your application. 5

FR102PH Wiring Diagram (110 VAC 60Hz) 6

FR102PH Wiring Diagram (220 VAC 60 Hz) 7

FR302DP Wiring Diagram (110 VAC 60 Hz) Pump Wiring (110 VAC) Intrinsic Safety Barrier Wiring (110 VAC) IMPORTANT! Voltage selector switch on pump must be set to 220 VAC for 220 VAC installations (see pump manual for details). Pump comes from factory set to 110 VAC. 8

FR302DP Wiring Diagram (220 VAC 60 Hz) WARNING! DO NOT attempt to wire the Intrinsic Safety Barrier or the 900DP meter to 220 VAC in any way. Damage and potential destruction to those components will result. 220 VOLT PUMP WIRING DIAGRAM AUX LEAD RATED 1.0 AMP Pump Wiring (220 VAC) Figure 1 Voltage Selector Switch IMPORTANT! When wired to 220 VAC, the voltage selector switch on the pump end (Figure 1) MUST be switched to the 220 VAC position. Intrinsic Safety Barrier Wiring (110 VAC) 9

FR902DP Wiring Diagram (110 VAC 60Hz) 10

FR902DP Wiring Diagram (220 VAC 60Hz) 11

FR910PM Wiring Diagram (110 VAC 60Hz) 12

FR910PM Wiring Diagram (220 VAC 60Hz) 13

Plumbing Instructions IMPORTANT! Remote dispensers and tank top pumps must be installed in accordance with all local, state, and national electrical code NEC/ANSI/NFPA 70, NFPA 30, NFPA 30A, and NFPA 395. Your Fill-Rite dispenser cabinet should be installed in a manner that does not use the plumbing to support the cabinet in any way. Safety and Emergency equipment should be installed per local, state, and national plumbing for flammable fuels guidelines. The following plumbing diagrams are suggestion for typical installation scenarios. Typical Wall Bracket Mount Plumbing 1 3 2 4 5 2 Item Description 1 Remote Pump (for use with FR102PH, FR902DP, FR910PM) 2 Electrical Conduit (Threaded rigid conduit, sealed fittings, conductor seal) 3 Wall Mounted Cabinet Dispenser (FR902DP, FR910PM) 4 Fluid Inlet Pipe ( Threaded pipe joints and connections should be sealed) 5 Safety Breakaway Valve CAUTION! Threaded pipe joints and connections should be sealed with the appropriate sealant or sealant tape to minimize the possibility of leaks. 14

Typical Pedestal Mount Plumbing 1 2 6 3 4 5 Item Description 1 Remote Dispenser Cabinet (applicable to FR102PH, FR902DP, FR910PM) 2 1 Inlet Pipe 3 1 Shut-Off Valve 4 Safety Breakaway Valve 5 Electrical Conduit (Threaded rigid conduit, sealed fittings, conductor seal) 6 Exterior Cover (Right side shown; left side not shown for clarity of installation) CAUTION! Threaded pipe joints and connections should be sealed with the appropriate sealant or sealant tape to minimize the possibility of leaks. 15

For accurate measurement and to prevent dispenser damage, dispenser and piping must always be filled with liquid and be free of air. Where applicable, the meter portion of your dispenser should be calibrated per instructions in the meter manual prior to its use. 1. Reset register to 0. 2. Remove nozzle from holder and turn the power on by lifting the switch handle. 3. Dispenser is ready for use. Insert nozzle into container to be filled and start flow of liquid. Do not exceed 50 PSI of line pressure. When desired amount of liquid has been dispensed, stop the flow at the nozzle. Turn the power off by pushing the switch handle down. Return the nozzle to its holder. Fluid Compatibility Model Gasoline Diesel Bio-Diesel Kerosene Lube Oil (60w and less) FR102PH FR302DP FR902DP FR910PM Wetted Parts Material FR102PH FR302DP FR902DP FR910PM Aluminum Stainless Steel Fluorocarbon Buna-N Cast Iron Carbon Nickle Plated Aluminum Acetal Polyester Steel Assembly and Disassembly WARNING! TURN ALL POWER OFF TO THE DISPENSER AND PUMP AT THE BREAKER PRIOR TO PERFORMING ANY SERVICE. Release any pressure in the piping, hoses, and nozzle prior to performing any service. Failure to comply with these warnings can result in explosion, fire, bodily injury, and possibly death. 3 Cabinets consist of three major pieces: 1) Base / back plate (internal equipment installed on it) 2) Cabinet walls that enclose the internal components 3) Cabinet top 2 1 16

Assembly and Disassembly (cont d) Access to the internal components is gained by removing the top and side panels. 1. Remove the screws on the front and sides of the cabinet. The screws are located around the perimeter at the top. The front screws pass through the sun visor over the display on metering cabinets. 2. Gently lift the top off of the cabinet and set aside. 3. If removal of the sides is required, disconnect any wire and mechanical connections to the internal components that would not allow the cabinet to be lifted off. FR302DP Access Panels The Fill-Rite Dispenser Cabinets have removable panels located on the side to allow easy access to the electrical wiring. FR102PH FR302DP, FR902DP, FR910PM Repairs Dispensers needing repairs should be taken to an authorized repair facility. The dispenser MUST be triple rinsed for safety before returning for repairs. 17

FR102PH Dispenser Cabinet Measurements Nozzle Boot Power Switch Nozzle Rest Hose Hook 18

FR302DP and FR902DP Cabinet Measurements Nozzle Boot Power Switch Nozzle Rest Hose Hook Nozzle Boot Power Switch Nozzle Rest Hose Hook 57.74 19

FR910PM Precision Meter Cabinet Dimensions Nozzle Boot Power Switch Nozzle Rest Hose Hook Nozzle Boot Power Switch Nozzle Rest Hose Hook 20 DC001404-000 rev. 0