Easytork Solenoid Valve IOM

Similar documents
Easytork Vane Actuator IOM

SERIES ASCO Valves DESCRIPTION OPERATION INSTALLATION. Positioning. Page1of5(Section1of2) I&M No.V9575R3 (Section1of2)

Airsweep Installation & Maintenance Manual. Airsweep Models VA-06 VA-12 VA-51 SECTION THREE SOLENOID VALVES

NEO-DYN MODEL 100P ENCLOSURE 7 ADJUSTABLE EXPLOSION-PROOF PRESSURE SWITCH

CIRCLE SEAL CONTROLS

B21 Series BASOTROL Gas Valve

MOUNTING, OPERATING, TESTING & MAINTENANCE INSTRUCTIONS FOR ROTEX 3/2 DIRECT ACTING ON/OFF/REGULATING NAMUR SOLENOID VALVE MODEL 30318, 30318LW

Installation& Maintenance Instructions

CIRCLE SEAL CONTROLS

STYLE 9300 FLOW/PRESSURE METER INSTALLATION & OPERATING INSTRUCTIONS

CV Control Valves Installation and Operation Manual

VQ400M SERIES CLASS A COMBINATION VALVES PRODUCT HANDBOOK APPLICATION

POWER GEAR SLIDE-OUT MANUAL

TBM Series 3-Way Ball Valve

Compressor Clutch Replacement Procedure

INSTALLATION AND OPERATING MANUAL

HAYWARD FLOW CONTROL TBH SERIES TRUE UNION BALL VALVE INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS

Solenoid Valves Type 3963

Installation & Maintenance Instructions

INSTALLATION AND OPERATING MANUAL

Type 2511/12. Type Type 2030 Cable plug. ASI cable plug. Dosing control. General technical data Orifice Type 6518

V200 Positioner. V200 P Pneumatic Positioner. V200 E Electropneumatic Positioner. Housing Material: Cast aluminium with polyester coating

WARNING: Do not use pumps for gasoline or highly flammable products! Do not use pumps for water based fluids, solvents or chemicals!

HALLMARK INDUSTRIES INC

Stainless Steel Pilot Piston Solenoid Valve 2MS Series for High Temperature & High Pressure

300 Series INSTRUCTION MANUAL. Compressed Air Filters Models 302 (grade) through 317 (grade)

INSTALLATION AND OPERATING

45 VALVE SERIES. 2-Position 4-Way 5-Ports, Installation & Service Instructions. Valve with Stem Operator, Installation & Service Instructions

Scale Feeder Manifold Water Filtration System Instruction Manual

40041 Heavy Duty ADA System with Booster Bracket for JK Heavy Duty ADA System with Booster Bracket for 2012 to Current JK

Liquid Turbine Flowmeter

For single and double operated actuators. Exhaust air recirculation (3/2 way function)

PUMP PRIMING INSTALLATION CHECK MOTOR ROTATION PUMP START-UP MOTOR REPLACEMENT DISASSEMBLY ELECTRICAL HOOKUP ASSEMBLY

CBC-300 Series & CBC-300C Series Dual Channel Adjust Clutch/Brake Controls

DAP-625S and DAP-875S

Product Information ROSS CONTROLS

Type 2000 Transducer Product Instructions

Manifold w/ Needle Valve Instruction Manual

Bulletin H-Tech 03 High Pressure Valves Series H

VA-908x Series Electric Rotary Actuators for Two-Position and Modulating Service

VQ400M SERIES CLASS A COMBINATION VALVES PRODUCT HANDBOOK APPLICATION

MODEL NUMBER: MEDIUM DUTY ONBOARD AIR SYSTEM

SUNC3000 / Item #40885

3/2-, 5/2- and 5/3-way Solenoid Valves for process pneumatics

3/2-, 5/2- and 5/3-way Solenoid Valves for process pneumatics

Pneumatic Division North America Richland, MI 49083

NOAH ACTUATOR NA-SERIES MANUAL EMICO EUNHA MACHINERY INDUSTRIAL CO.,LTD.

Premium Supply. Direct Push. Models PCK-3530-DP PCK DP PCK-530-DP. Operator s Manual and Installation Instructions

Hydraulic Gear Puller Instruction Manual

Direct mounting NAMUR solenoid valves for process valve actuators New Revolutionary Design- Worldwide Patents Pending

Model AM2 M40 Panel Installation, Operation, and Maintenance Manual

MODELS 100T AND 100TC ADJUSTABLE TEMPERATURE SWITCHES,

Gauge Adapter Instruction Manual

INSTRUCTIONS. Owner's Manual. Ionizing Air Nozzles Models AN-2 and AN-6

Dual/Triple Manifold Water Filtration Systems Instruction Manual

Thank You. for purchasing an Edelbrock Nitrous Oxide Injection System. Please take the time to read and understand the following.

ALITA LINEAR AIR PUMP OPERATION & MAINTENANCE MANUAL. AL- Model Number Date Code / Serial Number Date of Purchase

USER MANUAL. NEMA 48C Flange Mounted, Enclosed, Clutch Brake. FMCBE Model 500 FORM NO. L A (i)

STC 2P050 Series Solenoid Valves NSF Compliant Materials, 2 Way, Direct Acting

Installation, Operation and Maintenance Manual

Engineering Information. Solenoid Valves Principles of Operation. Solenoid Valves. Direct Acting Valves (Figures 1A, 1B)

Service/Installation Manual Full Wall Slide Systems

U00X ULTRASONIC LEVEL SWITCH. Ultrasonic Liquid Level Switches INSTALLATION AND OPERATIONS MANUAL. For Models: U002, U003 & U004

Flow Control. Before installation or maintenance, these instructions must be fully read and understood.

CRD610 Automatic Fitting Inserter

STC 2W Series Solenoid Valves

Electropneumatic Converters i/p Converters Type 6111 Mounting and Operating Instructions EB 6111 EN

INSTRUCTION MANUAL INSTALLATION, OPERATION, AND MAINTENANCE ACTUATOR MANIFOLD

PE 20 SERIES ELECTRIC POWER PUMPS

CLEAN ROOM DEVICES, LLC "WHERE TUBING AND FITTINGS COME TOGETHER"

97105 Inline. Ordering information. Technical data. Accessories See page 5

AIR COMPRESSOR OPERATING INSTRUCTION AND PARTS LIST

ELECTRIC ACTUATOR AND CONTROLLER FOR AKRON BUTTERFLY VALVES INSTALLATION INSTRUCTIONS

SERIES 90/91 R PNEUMATIC ACTUATOR OPERATION AND MAINTENANCE MANUAL. The High Performance Company

INTRODUCTION INSTALLATION

With regards to safety it is not necessary to check for correct operation.

Operating and Installation Instructions

Type 5411, Operating Instructions. Bedienungsanleitung Manuel d utilisation

NECO Pumping Systems

VE Series. Class "A" Gas Valves. Product handbook APPLICATION CONTENTS. General. Technical. Installation and operation. Various

Installation and Service Manual M² Sync Room Slideout System without Room Lock Connectors on Control Box

Dome-Loaded Pressure Reducing BD-Series

Read all instructions before installing and using. Installer: This manual must be delivered to the end user.

CLEAN ROOM DEVICES, LLC "WHERE TUBING AND FITTINGS COME TOGETHER"

Installation and Maintenance Manual

Operators Manual ECO-AIR-IVS Internal Valve Actuation System

Air Control Kit INSTRUCTIONS-PARTS LIST. Table of Contents HIGH VOLUME. 250 psi (1.7 MPa, 17.2 bar) Maximum Air Inlet Pressure

Horizontal Hydraulic Driver

CRD600 Automatic Fitting Inserter

For double-acting actuators. Crossover-free switching. Safety function in the event of power failure provided by mechanical return spring

FLEETWOOD TRAVEL TRAILER SLIDEOUT SYSTEM OWNER S MANUAL

Pump Installation and Service Manual HRS Hydromatic Retractable System

NEO-DYN MODELS 100T AND 100TC ADJUSTABLE TEMPERATURE SWITCHES; ENCLOSURE 3X FOR WEATHERPROOF APPLICATIONS INSTALLATION AND OPERATION MANUAL

STC 2L Series Solenoid Valves

Artesian Owners Manual

( Versions Available)

Electric Actuator Installation, Operation & Maintenance Manual

Dual Flow Manifold Systems Instruction Manual

Installation and Service Instructions for EX Series Explosion-proof Switches

I-317. AWWA Check Valves WARNING INSTALLATION AND MAINTENANCE INSTRUCTIONS SERIES 317 WARNING

Transcription:

Easytork Solenoid Valve IOM General This installation document is to be read in conjunction with the Easytork Vane Actuator IOM. Description The Easytork Solenoid Valve ( ESV ) series is intended for the control of Easytork Vane Actuator ( EVA ) with compressed air. The equipment can be mounted on the destined actuator with the enclosed material. Intended Use ESV series may be used in explosive atmospheres, if labeled accordingly. Therefore, it is necessary to use suitable magnet coils described in this manual. Coil Connection Category Width (mm) Standard DIN 43650 industrial form B connection NEMA 4X 22 or 1/2" conduit with 18" leads Explosion Proof 1/2 conduit with 24 leads NEMA 4, 4X, 7C, 7D, 9 36 CSA & FM Approved CL. I; Zone1 Ex m II T4; AEx m II CL. I; Div.1; GR. A, B, C, D CL. II; GR. E, F, G CL. III T4 Ta=-20 C to +60 C ATEX EX 3m cable & strain relief Ex m II T5 PTB 03 ATEX 2018 X 22 Ex II 2 G EEx m II T5 Ex II 2 D IP65 T95 C Intrinsically-Safe EN175301-803-A/ISO4400 Exia 30 CL. I; GR. A, B, C, D CL. II; GR. E, F, G CL. III; Div. 1;T5 Low Temperature DIN 43650 industrial form B connection NEMA 4X 22 or 1/2" conduit with 18" leads Low Power (1.1W) DIN 43650 industrial form B connection NEMA 4X 22 or 1/2" conduit with 18" leads Low Power (0.7W) EN175301-803-A/ISO4400 NEMA 4X 30 Note: This manual is to be used along with the manual of the magnet coil manufacturer. This manual refers only to the mechanical part. Magnet coil manufacturer manual refers to the electrical part of the equipment. Easytork warrants and represents only the ESV body, and not the magnet coil. Consult with magnet coil manufacturer for additional information. Applications ESV is meant for adaptation to the EVA. The ESV is a 5 port, four-way, two-position (5/2) valve. There are two pressure ports 2 & 4 (P2 & P4), two exhaust ports 3 & 5 (P3 & P5) and a common air supply port 1 (P1). There is one open hole (C) for interface with air reservoir. The provided sleeve should fit in the actuator s nest hole, as identified in the illustration. Caution: Do not close unused ports. The solenoid valve will not be able to operate properly. Air Supply All ESV has a minimum operating pressure of 30 psi (2 bar); maximum operating pressure of 150 psi (10 bar), except for Intrinsically-Safe and Low Power Series with a minimum operating pressure of 30 psi (2 bar); maximum operating pressure of 120 psi (8 bar). Operate the ESV only with clean and lubricated or nonlubricated compressed air with a quality level 5 according to ISO 8573-1. Non inert gases cannot be used. In case of lubricated compressed air, users need to dissipate the exhaust air with suitable measures. The intake may not happen from explosive atmospheres. In the fail-safe mode, environment air never enters ESV through vacuum associated with spring-return actuators. ESV Temperatures Limitations The standard temperature limits for the ESV are -20 C (-4 F) to +80 C (+176 F). Always consult with a representative of EVA for suitability and recommended practice. It is essential to use an air dryer for the air supply to avoid any moisture for use in sub-zero Celsius temperatures. Coil Temperatures ESVs are supplied with coils designed for continuous duty service. When the solenoid is idle for a long period, the solenoid coil becomes hot and can be touched with the hand only for an instant. This is a safe operating temperature. Any excessive heating will be indicated by smoke and odor. 1

Operation Fail-safe The ESV is able to set the EVA as either fail-safe (fail-open or fail-close), or double acting mode. ESV can also run manual override in the event of electrical AND/OR air supply outage. Double Acting Manual Override In conjunction with the EVA, the ESV manual override provides desired movement during an electrical AND/OR air supply outage. First set ESV into double acting mode. Rotate manual override counter-clockwise to I. Valve will now be in the same position as when the solenoid is energized. To disengage manual override, rotate manual override clockwise to 0. Valve will be in the same position as when the solenoid valve is de-energized. Caution: Always disengage manual override position 0 during normal course of operation. Caution: Switch ESV back to intended function (double acting or fail-safe) after engaging manual override. 2

Installation Basic Check coil label for correct voltage and frequency. Never apply incompatible fluids or exceed pressure rating of the valve. Installation and maintenance to be performed by qualified personnel. Caution: To prevent the possibility of electrical shock from the accessibility of live parts, connections to all open frame solenoid coils must be through the supplied DIN style connector with sealing gasket installed. Flow Reducer Any usage of Easytork actuator without speed control could void warranty. Caution: Ensure that the anti-tamper device is locked after double-acting or fail-safe switch is set in place. The standard anti-tamper device will discourage accidental tampering of actuator function. For other anti-tamper setups, consult with Easytork. Note: Under no circumstances will Easytork accept responsibility or be liable for installation negligence or intentional tampering of the ESV. Fail-Safe in Open or Close To convert from fail-safe open to close, or vice-versa, reattach the EPV to the EVA by rotating the ESV 180º. Ensure ESV set as fail-safe configuration. Switch orientation of grub screw to ensure non-interference with installation. Double Acting or Fail-Safe The ESV is able to set the EVA as either fail-safe (open or close), or double acting mode. To switch the actuator configuration from fail-safe to double-acting or vice-versa, a user only has to rotate a switch on the ESV. 3

Mounting to EVA The ESV may be mounted in any position. 1. Install grub screw onto EVA using a 2 mm hex key wrench. This ensures the correct orientation of the solenoid if removed in future. 2. Verify O-rings are over port 2 and port 4 to interface with the NAMUR pad on the actuator. Also verify O-rings are on both sides of the sleeve. 3. Position the solenoid valve to the actuator. Then install two socket head cap screws in offset center holes on either side. Hand screw a few turns into the actuator. Then tighten the screws evenly, using a 5 mm hex key wrench. Note: Do not over-tighten mounting screws. This may damage the threading of the EVA. Testing Coil First carry out an electrical test before pressurizing the system. Energize the coil a few times and pay notice to a metal click which signifies the solenoid operation. Piping Connect piping or tubing to valve according to markings on valve body. Refer to flow diagrams in the operation section. Apply pipe compound sparingly to male pipe threads only. If applied to female valve threads, the compound may enter the valve and may cause operational difficulty. Easytork recommends the use of flexible pneumatic tube and pushtype fittings rather than hard pipe. This avoids pipe strain on the valve and provides easier and faster installation and removal. When tightening the fittings, do not use pilot assembly and coil as lever. Locate wrenches applied to valve body or fittings as close as possible to connecting point. Caution: To avoid damage to the valve body, do not overtighten pipe connections. If Teflon tape, paste, spray or similar lubricant is used, use extra care when tightening due to reduced friction. When Teflon tape, paste, spray or similar lubricant is used, make sure debris does not enter into solenoid valve body as it may damage solenoid valve. Electrical Connections Note: To protect the solenoid valve, install a strainer or filter, suitable for the service involved, on the inlet side as close to the valve as possible. Clean periodically depending on service conditions. Electrical connections are only to be made by trained personnel and have to be in accordance with local regulations and standards. Caution: Turn off electrical power supply and de-energize the electrical circuit and voltage carrying parts before starting to work. Depending on the electrical component s voltage, unit must be provided with an earth connection and satisfy local regulation and standards. The equipment can have one the following electrical terminals: Spade plug connections according to ISD-4400 or 3x DIN- 46244 (when correctly installed this connection provides IP-65 protection). Embedded screw terminals in metal enclosure with Pg cable gland. Spade terminals (AMP type). Flying leads or cables. 4

Maintenance Provisions should be made for performing seal leakage, external leakage, and operational tests on the valve. Caution: To prevent the possibility of a serious injury or property damage, turn off electrical power, depressurize valve, and discard vent fluid in safe area before inspecting or servicing the valve. Preventive Maintenance Prepare and follow a routine inspection schedule based on the media, environment and frequency of use. The medium flowing through the ESV should be free from dirt and foreign material. Clean the valve strainer or filter as required to keep the valve free of contamination. In extreme cases, contamination will cause faulty valve operation and the valve may fail to shift. While in service, the valve should be operated at least once a month to ensure proper operation. Note: Easytork s warranty and liability of the ESV are voided if improper protection results in dirt inside the ESV. Disassembly 1. Ensure that the solenoid valve is separated from the supply voltage and supply air. 2. Disconnect all leads from the solenoid valve. 3. Release the two hexagon socket screws and remove the solenoid valve from the actuator. Causes of Improper Operation Incorrect pressure: Pressure must be within the range described in this manual. Faulty control circuits: Check the electrical system by energizing the solenoid. A metallic click signifies that the solenoid is operating. Absence of the click indicates loss of power supply. Check for loose or blown fuses, open circuited or grounded coil, broken lead wires or splice connections. Burned-out coil: Check for open circuited coil. Replace coil as necessary. Check supply voltage; it must be the same as printed on the coil. Low voltage: Check voltage across the coil terminals. Voltage must be at least 85% of specified rating. Coil Replacement 1. Verify that the power is off. 2. Disconnect grounding and supply wires from coil. 3. Remove coil nut and slip coil off the armature assembly tube. 4. Install new coil and replace nut. 5. Make electrical hookup to coil. Service Notice Except for coil replacement, all ESV series valves are not repairable. When any performance problems are detected during routine inspection, replace valve immediately. High Performance Butterfly Valve When the ESV is in the fail-safe mode, the ESV can only be used to fail-safe to close position a high performance butterfly valve when the high performance butterfly valve seat retainer is downstream. The ESV can only be used to fail-safe to open position a high performance butterfly valve when the high performance butterfly valve seat retainer is upstream. All other setup cannot be used and will void Easytork s warranty. TWO YEAR OR TWO MILLION CYCLE WARRANTY Note: Easytork s warranty and liability of the ESV are voided if there are damages caused by negligence, misuse, improper application, service or operation or lack of service of product. EASYTORK offers a limited repair or replacement warranty on all EASYTORK Vane Actuator (EVA) Series, Easytork Solenoid Valve (ESV) Series, and Easytork Air Pilot Valve (EPV) Series (the Products ). Simply stated, if any of Goods fails within two years or two million cycles, whichever comes first, of delivery by Distributor, despite being properly installed, operated in accordance with industry standard operating procedures, and properly serviced and maintained, EASYTORK will repair the product, or at our option replace the unit with another of equivalent material and design in exchange for the defective unit. This warranty only applies to failures due to defective materials, workmanship, or premature wear in the Goods. Under no circumstances will EASYTORK accept responsibility or be liable for any costs other than to repair or provide a replacement of the defective Goods. EASYTORK shall not have any liability to any customer for the loss of product, loss of profit, loss of use, or any other indirect, incidental, special or consequential damages as a result of this express limited warranty. Actuator is designed to continuously operate within 15% of specified air pressure in either DA or FS design. EASYTORK DISCLAIMS ANY WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE OR ANY OTHER IMPLIED WARRANTY IN CONNECTION WITH THE CUSTOMER S PURCHASE OF ANY PRODUCT UNDER THIS AGREEMENT. 5

Parts List 6