NEW. MAGNASPHERE L2C HSS Technology. Only concealed contact to meet UL 634 Level 2 High Security Standard

Similar documents
Magnetic Contacts. GE Security. Specialty Mount Magnapull contact mini Magnapull magnetic pull-apart cord

INSTALLATION MANUAL FSS1 HIGH SECURITY DOOR MONITORING SENSOR

D-Drive Controller Retrofit Instructions

Excel Series Value Engineered Access Hardware

180 Series 3/4" and 1" Steel Door Recessed Switch Sets

1.63" 4.14 cm. Regular Gap Series 1 / 2" 1075T U L LISTED. NOTE: White only. 1.08" 2.74 cm. 1.08" 2.74 cm. Regular Gap Series 1 / 4" 1125T U L LISTED

FIRE/LIFE SAFETY SERIES PRODUCT SELECTION GUIDE

½ DODGE CUMMINS

150 Series 1/2" Recessed Switch Sets

KOBOLD VKA FLOWMETER/SWITCH. User Instructions. Manual-VKA_03-04

4840 with EDA arm and 459 Door Loop

WARRAntY & HInGE types

M-50/55 Series. Fixed setting flow switch with in-line flow

Service Manual. Bolens 683 Series Box Frame Tractor IMPORTANT: READ SAFETY RULES AND INSTRUCTIONS CAREFULLY

M Installation Guide. PRECISION Manifold Series. Introduction. A. Assemble Manifold Components

Solid Dielectric, Single Phase Recloser

Installation Instructions RF5010 and RF5210

Retrofit LED Basics Series. Economical 4", 5" and 6" LED Retrofit Trims

Overhead Door Holders/Stops

EMLock 1500 Series. MEA Listed

FES112 HIGH SECURITY ELECTRIC CUSTODIAL STRIKE INSTALLATION MANUAL

INSTALLATION 8310/8320

M-61-F. Fixed Set Point Flow Switch. Description. Operating Principle. Application Examples.

L DODGE CUMMINS BD FLOWMAX LIFT PUMP KIT

INSTALLATION INSTRUCTIONS

Electromagnetic Locks DORMA EML

Encore Manual Powder Spray Gun Trigger Switch Replacement

BASE SHOE RAILING SYSTEMS

KAWNEER 1686 EL CONCEALED EXIT DEVICE

L/6.7L DODGE CUMMINS

FIRE/LIFE SAFETY CLOSERS/HOLDERS SERIES

LEAK TEST PROCEDURE APPLICABLE TO DC3 INTELLI-GRIP LIFTERS MODELS MRT4-DC3, MRTA8-DC3, MRTALP8-DC3 AND PC/P1-DC3 SERIES

50RS-12 Series Miniature 1/4" Recessed Switch Set

TECTUS Concealed Hinges

KAWNEER 1686 CONCEALED EXIT DEVICE

M GT 2005 up Mustang ENGINE START Push-Button INSTRUCTION SHEET

Encore and Spectrum (Global) Powder Feed Center Clamping Cylinder

Installation Instructions

EXPLOSIONPROOF PROTECTION SIMPLIFIED PLEXPOWER LIGHTING AND POWER PANELBOARDS

GT Series Sealed Ultraminiature Toggle Switches

PREVIOUS GENERATION. Encore Manual Powder Spray Gun Trigger Switch Replacement. Introduction. Preparation. Gun Disassembly

RABO Rotary Gas Meter

Dura Force Disc Brake System Service Manual

cel SECURITY DOOR CONTROLS Value Engineered Access Hardware sdcsecurity.com Power Supplies Exit Switches

OEM BYPASS LIFT PUMP KIT

M32 600lb Holding Force Magnalock

4640 shown POWER OPERATOR HOLD-OPEN ACCESSIBILITY* NON-HANDED NON-SIZED

DC3000 Series. Door Closers

½ DODGE CUMMINS

RETRO SOLUTIONS PRODUCT CATALOG

MODEL E REPAIR KIT INSTALLATION INSTRUCTIONS

SYSTIMAX 360 ipatch InstaPATCH Fiber Shelf Instructions

GATES-ELECTRIC AND MECHANICAL SELF CLOSING 2000 SERIES

LED SAFETY LIGHTING CATALOGUE

January 2018 PRICE SCHEDULE A 2.0 Vehicular Traffic Control

EL110 Electric Cabinet Lock


Product Description. Product Numbers. Warning/Caution Notations. Required Tools. Wiring. Prerequisites

INSTALLATION & OWNER S MANUAL

ADE5F. Inspectable Armour Cable Gland NEW! 2012 Eaton Corporation. All rights reserved.

HIGH SECURITY SERIES

For Technical Assistance, call Competition Engineering's Tech Line at (203) , 8:30am-5:00pm Eastern Time COMPETITION ENGINEERING

EMLock 1500 Series. MEA Listed. New Modular Kits. Online System Wizard and Project Manager at

CIRRUS AIRPLANE MAINTENANCE MANUAL

Installation Notes: #86000-R Race Series +3.5 L/T Kit

M-60X. Explosion Proof Flowswitch with In-line Flow. Description. Key Features. Operating Principle. Applications. Custom Version Available

SURGE RESTRAINT FIG. 055

INSTALLATION INSTRUCTIONS

Certus Model 460 Turntable Manual. 25-Jun-2007

DODGE SuperRail Mounting Kit #0848

General Information. Notations and Conventions. Compatibility Check. Kit Description. Call-Outs. Part Lists Great Plains Manufacturing, Inc.

LCN SEM SERIES FEATURES. SEM 7820 MAGNET Die Cast, Floor mounted. SEM 7870 MAGNET Die Cast, Dual Sided Floor mounted. SEM FEATURES

Installation Instructions

A Series 1-4 Pole Rotary Switches

Trine-Electric Strikes & Accessories

1000 Series Miniature Slide Switches

INSTALLATION INSTRUCTIONS

M-200X. Explosion Proof Adjustable Flow Switch with Right Angle Flow. Key Features. Description. Operating Principle. Applications

M-8100EP. Installation Guide ENGINEERED PLASTIC MANIFOLD SERIES. Introduction. A. Assemble Manifold Components

Pre-Installation Instructions

BIG BLASTER XHV Air Cannon Retrofit Kit Installation Instructions

System 1 Modular Post-Mount Supports

Upgrading the Sure Coat Modular Gun Control System

KONE EcoMod Escalator Maintenance Instructions

Jensen. Mailboxes. Multi- Tenant. The power of stainless. The price of aluminum. USPS Approved the STD 4C Mailbox see pages 4-7

Certus Model 450 Turntable Manual. 21- Dec- 2006

PCVS Series Control Valve Supervisory Switch

UL (9050, 9100, 9150) PG. 10 PG.

Installation, Service and Parts List Series 56,800 for Class I & II, Division 2 Manual Adjust Brakes

Installation Instructions for Series 3100V Low Level Indicator

INSTALLATION INSTRUCTIONS

*ININST.1002* 1690 Touchbar. Index:

C&K 1000 Series Miniature Slide Switches

INSTALLATION INSTRUCTIONS

Biometric High Security Safe

MULTI 9 System Catalog IEC Rated C60N/H/L Circuit Breakers

Explosion Proof Receptacle - Integral Circuit Breaker - Class 2 Division 1-30 Amp 480VAC

January 2018 PRICE SCHEDULE A 2.0 Vehicular Traffic Control

INTERNAL SURGE TANK TM

M-100 Adjustable flow switch with right-angle flow

Transcription:

NEW MAGNASPHERE expands its L2 series HSS product line to include the revolutionary L2C series of next generation sensors that meet and exceed UL634 Level 2 High Security Standard for installations where concealed sensors are desired for both security and aesthetics. ULI HIGH SECURITY LEVEL 2 CUL HIGH SECURITY THE INSIDER THREAT IS REAL. Experts agree that the most devastating threats to government and corporate security have come from employees who were deemed trusted insiders. Armed with simple magnets unscrupulous insiders can disable even triple-balanced BMS magnetic contacts while the system is unarmed, and enter undetected at a later time, leaving no evidence of tamper. MAGNASPHERE L2C HSS Technology Only concealed contact to meet UL 634 Level 2 High Security Standard Incorporates patented removal (pry) tamper circuit Installs in one inch diameter hole or standard ANSI door cut out ANSI model a retrofit / upgrade to old 2757 / 67 BMS contacts American made, built with MAGNASPHERE switch technology Resists permanent contact welding (power surges, stun guns, lightning) Single and dual alarm contacts available Compatible with all control panels Highest level of security for every installation Competitively priced

CONSTRUCTION AND TECHNICAL SPECIFICATIONS L2C-XXX-A (ANSI Cut Out) TAMPER BRACKET Housing: Brass Max Current: 0.25 A Resistive Max Power: 0.250 W Max Voltage: 30 VDC Max Actuation Gap: 0.125 * Single or Dual Contacts Hermetically Sealed Switch Contacts Wire Lead Type: Solid Color-Coded Lead Wires, 22 AWG Fully Epoxy Potted Assembly Operating Temperature: -40 C to +80 C Suitable for Indoor Use Intended for Connection to UL Listed Compatible Control Panels Removal Tamper Circuit: PATENTED DESIGN #RE 39731, #6603378, # 7944334 & Other Patents Pending SWITCH MODULE.62 " 2.5 " MAGNET MODULE 4.125 " 4 7/8 " 3.374 2x #8.9 " 1 1/8 " 3 1/2 ".08 " TYP. 1 1/4 " 2x #8 B * 0.0625 for UL624 Level 2 installation 1 1/8 ".9 " 1 1/4 " 1/32" SPACER(s) AS NEEDED P/N: 1317 Detail B MAGNASPHERE Corp. provides superior performing magnetic contact sensor technology for the residential, commercial, and federal government security markets. The HSS s leading-edge technology aims to set new industry standards for high security sensors while providing an affordable and more effective alternative to reed-based security contacts. To learn more about the MAGNASPHERE L2 HSS High Security Sensor visit or call 262-347-0711. 03-2012 L2S-XXX-A-SCHM DRAFT

CONSTRUCTION AND TECHNICAL SPECIFICATIONS L2C-XXX (1 Diameter Concealed) Housing: Switch ABS, Magnet - Brass Max Current: 0.25 A Resistive Max Power: 0.250 W Max Voltage: 30 VDC Max Actuation Gap: 0.125 * Single or Dual Contacts Hermetically Sealed Switch Contacts Wire Lead Type: Solid Color-Coded Lead Wires, 22 AWG Fully Epoxy Potted Assembly Operating Temperature: -40 C to +80 C Suitable for Indoor Use Intended for Connection to UL Listed Compatible Control Panels Removal Tamper Circuit: PATENTED DESIGN #RE 39731, #6603378, # 7944334, # 8487726 & Other Patents Pending 1 3/4 2 X #8 FLAT HEAD (UNDERCUT SCREWS) #22 AWG x 12" (6 WIRES MAX) TAMPER BRACKET SWITCH MODULE MAGNET MODULE.98 SIZED TO FIT 1 HOLE 1.02 1 1/4.08 2 5/8 A 1 1/8.94 * 0.0625 for UL624 Level 2 installation 1 1/4 1/32" SPACER(s) AS NEEDED P/N: 1221 Detail A MAGNASPHERE Corp. provides superior performing magnetic contact sensor technology for the residential, commercial, and federal government security markets. The HSS s leading-edge technology aims to set new industry standards for high security sensors while providing an affordable and more effective alternative to reed-based security contacts. To learn more about the MAGNASPHERE L2 HSS High Security Sensor visit or call 262-347-0711. 03-2012 L2S-XXX-A-SCHM DRAFT

How the HSS L2C Removal Tamper Circuit Works The MAGNASPHERE HSS L2C Series are the only concealed devices available on the market that incorporate a secure anti-tamper circuit. This patented feature is available on both the ANSI cut out and the 1 diameter recessed versions of the L2C. L2C-XXX-A Models for Use in Standard ANSI Door Cut Out (Refer to product sheet for visual graphics) The Tamper bracket, containing the tamper switch actuating magnet is inserted into the ANSI cutout first, and secured with screws to the ANSI mounting tabs. The Switch module is incorporated into the brass cover plate and contains the Magnasphere alarm switch(es) which are oriented toward the face of the Switch cover plate towards the corresponding actuation magnet mounted in the door, and the Magnasphere tamper switch which is oriented in the opposite direction toward the magnet in the Tamper bracket. The cover plate is secured to the Tamper bracket via mounting holes that are inboard on the cover and is secured to corresponding mounting holes in the Tamper bracket. Any attempt to access the switch or wiring will require removing the Switch module/cover plate. As this is removed, the Tamper switch is moved away from magnet in the stationary tamper bracket, which results in an alarm condition. This Tamper bracket Switch module/cover plate arrangement is also ideal when the device requires a periodic test of the tamper circuit. The tester need only loosen the mounting screws on the Switch module / cover plate, pull the module out from its seated position and the alarm switch will activate for the test. L2C-XXX Models for 1 Diameter Recessed Installation (Refer to product sheet for visual graphics) The Tamper device, containing the tamper switch actuating magnet is a tapered cap that adheres to the switch housing via double sided tape pads, and aligns the tamper magnet opposite the tamper switch. The taper allows the switch / tamper assembly to be inserted into the 1 diameter mounting hole. Attempts to remove the switch assembly, will result in the reverse taper barbs of the tamper cap engaging the inside edge of the door frame, and pulling the tamper cap tape pads loose from the switch module. As this tamper cap / magnet releases from the switch module, an alarm signal is generated. NOTE: The L2C switch module has locking side clips that make it extremely difficult to remove the switch module without damaging it. Therefore, removal of the switch to test the tamper circuit is not recommended. If the L2C is used in wood or aluminum door frame installations that require a test of the tamper circuit, this can be accomplished by using a specially magnetized L2C Tamper Test Magnet (Magnasphere part number 1384). Simply open the door (which removes the L2C actuating magnet) and place the Tamper Test Magnet beneath the switch this will cause activation of the tamper switch for the test.

L2C-A Wiring Schematics Contact State Shown with Magnet in Place Model L2C-101-A Model L2C-111-A AUX L2C Wiring Schematics Contact State Shown with Magnet in Place Model L2C-101 Model L2C-111 AUX