Extensible Unit - VCE2a

Similar documents
SABRE VRN2a ENGINEERING BRILLIANT SOLUTIONS

CONTENT. EPE METALCLAD SWITCHGEARS AMS SERIES 12kV AMS METALCLAD SWITCHGEAR 24kV AMS METALCLAD SWITCHGEAR 40.5KV AMS METALCLAD SWITCHGEAR

SafeLink The Ultimate RMU. Rex de Bruyn PTMV New Zealand. ABB Ltd - Page 1 ABB

COMPACT SUBSTATION GUIDE

Key features. DESIGNS: - Conservator type - Hermetically sealed

TECHNICAL SPECIFICATION OF 11KV SF6 / VCB METAL ENCLOSED, INDOOR (PANEL TYPE) / OUTDOOR RING MAIN UNIT (RMU). (IEC standard equipment)

with Vacuum Circuit Breaker HAF

017: 1998 CEB STANDARD RING MAIN UNIT CEYLON ELECTRICITY BOARD SRI LANKA

AIR INSULATED METAL ENCLOSED SWITCHGEAR AND CONTROLGEAR

abb SafeLink SF 6 Insulated Ring Main Unit Installation and Operating Instructions Switchgear Division Auckland, New Zealand SLMIO ver 2.

11kV Compact Switchgear. tec - range. Minimum to Zero SF6 Insulation Gas. Outec Controls

Medium Voltage Metal-Enclosed Switches

Descriptive bulletin. Medium voltage load interrupter switchgear Reliable, low maintenance and economical for distribution applications

NXPLUS C Single busbar. Maintenance-free for lifetime

Air-insulated switchgear UniGear type ZS1

SWITCHGEAR DIVISION PRODUCT PROFILES

Medium voltage compact switchgears. rated voltage 12 and 25 kv rated current 400 and 630 A

SUBSTATION VACUUM CIRCUIT BREAKER (38KV)

SUBSTATION VACUUM CIRCUIT BREAKER (15.5KV)

SUBSTATION VACUUM CIRCUIT BREAKER (25.8 / 27KV)

Metal Clad VCBs ~ Mk1

ME Switchgear with Vacuum Circuit Breaker and Auto-jet II Switch with Ground Position

Safe and Reliable. Flexible, Compact Design. Easy Installation and Maintenance

BHARAT HEAVY ELECTRICALS LIMITED, JHANSI

Medium Voltage Distribution PIX. Air Insulated Switchgear up to 24 kv PARS TABLEAU

MESG 12 / 17.5 / 24 / 36 KV

MEDIUM VOLTAGE SWITCHGEAR

Medium Voltage Metal-Enclosed Switches

MEDIUM VOLTAGE AIR INSULATED ARC-RESISTANT LOAD BREAK AND DISCONNECT SWITCHES

Bharat Heavy Electricals Limited (High Pressure Boiler Plant) Tiruchirappalli , TAMIL NADU, INDIA CAPITAL EQUIPMENT / MATERIALS MANAGEMENT

Gas Insulated Metal-clad Switchgear, HMGS!

CPG.1 Gas insulated, single busbar cubicle range Up to 27 kv / 2000 A / 31.5 ka Up to 38 kv / 2000 A / 31.5 ka IEEE Standards

AIR INSULATED EXTENDABLE SWITCHGEAR UP TO 12KV GUIDE

General. Main electric circuits Fuses compartment Operating mechanisms Cables connection compartment

Product Specification

COMPACT AND EXTENSIBLE RING MAIN UNIT. insulated Ring Main Unit with load break switch or integrated vacuum circuit breaker

A system fault contribution of 750 mva shall be used when determining the required interrupting rating for unit substation equipment.

Type SIMOPRIME A4, up to 24 kv, Air-Insulated Medium-Voltage Switchgear

Guide Specification. Three-Phase Solid Dielectric Trident-SR with SafeVu Integral Visible Break

VOLUME: IIIC SCHEDULE IIIC/4 11 KV AND 3.3 KV SWITCHGEARS

Metal Clad Switchgears

Metal-Enclosed Switches. Medium Voltage. Medium Voltage Metal-Enclosed Switches Contents

Outdoor live tank vacuum circuit breaker Type OVB-VBF for 24/36/40.5 kv applications

ZX-Family Gas-insulated medium voltage switchgear

SF 6 Gas Insulated Load Break Switch

33KV INDOOR SWITCHGEAR

Medium Voltage Standby non-paralleling Control GUIDE FORM SPECIFICATION

TGK Prefabricated Substation Technical Data

Medium voltage switchgear type W 12. rated voltage 12 kv rated current 630 A

Unitole UP kv Primary substations Motor control centres

5kV to 38kV, 630 Amp to 4000 Amp Indoor or Outdoor Application

Unitole UP kv Primary substations Motor control centres

DESIGN GUIDELINES LOW VOLTAGE SWITCHGEAR PAGE 1 of 5

Michigan State University Construction Standards SECONDARY UNIT SUBSTATIONS PAGE

ZF SERIES HV GAS INSULATED SWITCHGEAR (GIS) tgood.com. Energy. Fast.

SYSclad switchboard equipped with draw out type vacuum circuit breaker closed dooroperationoperation. SYSclad 12 17,5kV A.

MEDIUM VOLTAGE CE-B METAL CLAD SWITCHBOARDS. CE-B-C-en-REV

56-SDMS-07 REV. 01 SPECIFICATIONS FOR

PIX-H Metal-clad switchgear up to 17.5kV

MEDIUM VOLTAGE CE-B36 METAL CLAD SWITCHBOARDS. CE - B36 - C - en - REV

SWITCHCRAFT. Switchcraft Europe GmbH SWITCHCRAFT

32-SDMS-01 REV. 02 SPECIFICATIONS FOR

GE Consumer & Industrial Power Protection. New. SecoGear kV Metal-clad Switchgear. GE imagination at work

Circuit-Breaker Switchgear Type SIMOPRIME, up to 17.5 kv, Air-Insulated Medium-Voltage Switchgear.

HHD. High Voltage Fuses German DIN Standard. The temperature limiting function of the fuse striker pin. Design and construction.

Switchgear Type SIMOSEC, up to 24 kv, Air-Insulated, Extendable

RAPIER DSB Disconnectors

Power IT Air Insulated Cubicle Uniswitch

8DJ. Maintenance-free for lifetime

Typical Specification

with Vacuum Circuit Breaker HAF

MEDIUM VOLTAGE CE-B METAL CLAD SWITCHBOARDS. CE - B - C - en - REV

Publication No.: PSG

Fuse-links type CEF-VT Rated voltages 3/7.2 kv - 10/24 kv Rated current 0.5 A 6.3 A

ATR-MIX. METAL ENCLOSED SWITCHGEAR kV A ka

KYN28A-12 (GZS1) A.C METALCLAD REMOVABLE SWITCHGEAR FOR INDOOR USE CHINATCS

THP145 HYBRID GAS INSULATED SWITCHGEAR (HGIS) Energy, Fast! tgood.com

Benefits, typical uses

Medium voltage switchgear SafeGear HD 63 ka arc resistant metal-clad switchgear. ABB Group February 25, 2015 Slide 1

Catalog HA Edition up to 24 kv, Air-Insulated, Extendable. Medium-Voltage Switchgear. siemens.com/simosec

C1000 Series Automatic Cap Bank

Switchgear Type 8BT1, up to 24 kv, air-insulated. Medium Voltage Switchgear Catalog HA 26.

HHD HIGH VOLTAGE FUSES GERMAN DIN STANDARD. The temperature limiting function of the fuse striker pin. Design and construction.

SF 6 Gas Insulated Switchgear Type SDH714 for 72.5 to 145 kv

Switchgear Type SIMOSEC, up to 24 kv, Air-Insulated, Extendable

Metal Clad Air Insulated Switchgear

SF6 Load Break Switch 2017 FIL3 - S. Indoor Medium Voltage LBS With or without fuse 12kV- 24kV FIL3 D FIL3. 24KV SF6 Load Break Switch

24kV Medium Voltage Switchgear Metal-Enclosed (LSC2A)

2018 Consultant s Handbook Division 26 Electrical 2413 Switchboards

Fixed-Mounted Circuit-Breaker Switchgear Type NXPLUS C up to 24 kv, SF 6 -Insulated. Medium-Voltage Switchgear Catalog HA 35.

SF 6 Gas Insulated Switchgear Type SDH314 / SDHa314 for 72.5 to 145 kv

www. ElectricalPartManuals. com lncoming-6900 through 69,000 volts Outgoing-2400 through 13,800 volts Ratings:

32-SDMS-02 SPECIFICATIONS FOR

UniGear. Technical Guide

XIRIA Green, Smart, Compact solution

MV Air Insulated Switchgear TAP17. Technical Data TGOOD

Gas Insulated Switchgear

UniPack compact secondary substations (CSS) upto 36 kv For safe, reliable and space saving power distribution solutions

Product Specification Guide. Title: Southern States 362 kv RLSwitcher Vertical Interrupter Style Reactor Switcher

SF 6 gas insulated RMU SafePlus 24 kv. ABB SafePlus 24 kv SF6 gas insulated RMU 1

Transcription:

ELECTRICAL INDUSTRIAL COMPANY (EICo) LUCY SWITCHGEAR Extensible Unit - VCE2a (Sabre)

Electrical Industrial Company (EICo) Lucy Switchgear Extensible Unit VCE2a Front Panel:

ELECTRICAL INDUSTRIAL COMPANY (EICo) LUCY SWITCHGEAR (Sabre) EXTENSIBLE UNIT VCE2a: General The Extensible Unit VCE is compact SF6 insulated Vacuum Circuit Breaker Unit. The Unit can be mounted to the smallest distribution transformer, or be sited in a free format. The unit is suitable for both indoor and outdoor applications. the unit has a long service life and requires virtually zero maintenance. 1- Stainless Steel Gas Enclosure The gas enclosure is manufactured from stainless steel and fabricated utilizing automatic 'robot welding' techniques to produce consistent leak- free equipment. 2- Housing The housing of the Sabre VCE2a is fully treated; using zinc coated steel and electro statically applied oven cured paint, to resist weather and pollution attacks. All units are provided with a hinged, weatherproof and lockable door. The external support legs provide a Extensible bushing height of 1072mm, 3-Tee-Off Circuit Breaker The circuit breaker comprises of three vacuum interrupters, which have a fault-make, fault-break rating. Opening of the circuit breaker is achieved by manually operating the handle as standard. Earthing of the outgoing cable, from the circuit breaker, is achieved by the use of the circuit breaker in series with the off-load disconnect or / selector switch.. 4- Extensible The extensible bushing are available in three versions,left hand only, right hand only and both left and right hand. All versions have a extensible bushing height of 1072 mm.

5- Operation All operating positions and instructions are indicated on the main panel at the front of the unit. Operation is by means of manually independent mechanisms, which are mounted externally to the gas enclosure The tee-off vacuum circuit breaker has two operating positions, 'ON' or 'OFF', with an off-load, interlocked selector allowing isolation & earthing of the tee-off circuit A single, "Y"-bar type operating handle is stored at the front door. Symbols located on the end of the operating handle indicate direction of operation... 6-Test Facilities (Extra Option) The Sabre VCE2a has fully interlocked integrated ring switch cable test facilities in accordance with ENATS 41-36 requirements. Access to the test terminals is achieved by pulling a lever located on the front fascia inside the front door. This will allow the cover underneath the unit to drop down. 7- Interlocks Positive safety interlocks are incorporated on all switch positions. 8- Padlocks The door has a quarter-turn lock that can be padlocked. The handle has a padlock hasp hole size 8mm diameter. All switch and selector positions can be padlocked. The padlock hasp hole size is 8.5mm diameter. 9- Transformer Protection The circuit breaker enables the VCEa to protect transformers with ratings well in excess of those of a comparable HV fused unit. Protection is achieved by the use of ring core current transformers in combination with Time Limit Fuse links or a protection relay. The ring core current transformers are mounted around the rear teeoff bushings, external to the SF6 chamber, but within the cladding of the unit. The Time Limit Fuses, or the protection relay, are mounted behind a cover at the front of the unit. 10- Time Limit Fuse Protection (TLF)

Dual ratio CT's are provided as standard transformer protection. Access for CT ratio change is provided by means of a cover plate on the front panel of the unit. 11- Cable Termination The tee-off bushings are located at the rear of the unit and are in line bolted connections M12 threaded.all tee-off bushings are fitted with white stress relief collars and must not be removed unless a taper kit is being fitted (see picture below) If cable boxes are fitted,then the bushing are accessible by removing the cable box side cover. The maximum cable size that can used is : 300mm2 3- core 500mm2 single- core The following type of terminations can be used with the VCEa Tee-off bushings Insulating bushing boot Tee-off taper kit ( with white stress relief collar removed) Torque Setting on cable bushings M12 copper thread or into copper 35 Nm Insulating Bushing Boot Tee-off taper kit

TLF TRIP PROTECTION SYSTEM DIAGRAM:

12- Earthing The Sabre VCEa unit should be earthed at the primary earth point located at the rear of the unit.

13- VCEa Unit Floor Mounting Dimensions The units are designed for bolting down onto a concrete plinth using 4 - M16 bolts.

ELECTRICAL INDUSTRIAL COMPANY (EICo) LUCY SWITCHGEAR Extensible Unit VCE2a schematic line diagram:

Technical data Extensible Unit VCE2a 1- Rated Voltage 12KV (15.5KV) 2- Impulse Withstand Voltage 75KV (95KV ) 3- Normal Current - BUS BAR 630Amp - Tee- Off Circuit Breaker 250Amp 4- Short Circuit Peak Making current - Tee-Off Circuit Breaker 50KA 5- Short Circuit Breaking Current - Tee-Off Circuit Breaker 20KA RMS 6-3 Second Short Time Current - Tee- Off Circuit Breaker 20KA 7- Earth Switch Peak Making Current - Tee-Off Circuit Breaker 7.9 KA 8- Internal Arc Rating 20KA 1 sec OPTIONAL CABLE BOXES INTERNAL ARC RATING STANDARD TYPE 12.5KA 1 sec 9- Gas pressure - Min Operating Pressure O Bar G 10- IP Rating up to IP54W 11- Weight 290kg

ELECTRICAL INDUSTRIAL COMPANY (EICo) Extensible Unit VCE Dimensions: LUCY SWITCHGEAR