MOBILE SUBSTATION GUIDE Certificate Number FM35831
Mobile substations by their nature offer the flexibility and the opportunity to ensure a reliable energy supply. Mounted on a trailer, their compact and mobile design allows for the substation to be easily transported and provides a quick solution of fast integration to the system. The end product offers a complete substation assembly and is ready to connect, plug and play. The module contains all of the necessary equipment required for a complete substation: a power transformer bay fitted with a power transformer, GIS or hybrid GIS switchgear, AIS switchgear, protection and control equipment, as well as AC and DC auxiliary supplies. The trailer s external dimensions are sized to comply with road and sea transportation regulations. Its base-frame is designed to ensure the protection of the switchgear from structural constraints despite transportation on rough road surfaces. WHY THE NEED FOR MOBILE SUBSTATION? The main applications of mobile substations are: For emergency scenarios In the event of natural disasters, where energy supply is vital During maintenance procedures and emergency repairs In the event of substation equipment failure As temporary solutions For loads which may be seasonal For large events where power demand by the local substation is too high such as exhibitions For when a fixed substation construction takes a long time, and immediate supply is required 2
CUSTOMER BENEFIT THE BENEFITS INCLUDE: Maximum operator safety Easy interface Minimum site work Maximum mobility for transportation and relocation Resistant to harsh weather conditions Limited footprint required Fast alternative reliable power supply Cost effective RELIABLE FAST SAFE LIMITED FOOTPRINT 3
RELIABLE ENERGY SUPPLY WHEREVER AND WHENEVER NECESSARY CHARACTERISTICS OF MOBILE SUBSTATIONS Power Transformer Power Up to 10MVA Type Oil Immersed Voltage Ratio 66/11kV 30/11kV Cooling ONAN Vector Group Dyn11 Short Circuit Impedance 8% Voltage Regulation NLTC/OLTC Switchgear Hybrid GIS/AIS type Rated Voltage 72.5kV 36kV 12kV Type Hybrid GIS, Combined Disconnector, Earth Switch and Circuit Breaker, Outdoor Hybrid GIS, Dead Tank Circuit Breaker, Outdoor Air Insulated Switchgear, Indoor Manufacturer ABB, PASS M00 Schneider Electric, VOX Medelec, MSGair Rated Impulse Withstand Voltage Rated Normal Current Rated Breaking Capacity Rated Frequency 325kV 170kV 75kV up to 1250A up to 31.5kA 50Hz Surge Arresters Instrument Transformers Protection and Control Cubicle Automatic Voltage Regulator Metal Oxide Arrestor, (ZnO), Polymeric Housing suitable for outdoor application, Discharge current, 10kA Voltage transformers and Current transformers for protection and measurement circuits. Differential/Overcurrent/Earth Fault, Integration to SCADA system can be provided MR, Provided for 10MVA Auxiliary Circuit Auxiliary Transformer Auxiliary Transformer Protection DC System 50kVA, 11/0.4kV Lucy, MK5, SFS1E, Fuse Switch 110Vdc, 20A, 55AH 4
Other Components AC/DC Distribution, Air Conditioning System, Fire Detection System. Factory Tests The Complete Mobile Substation is Pre-tested before Delivery Including Functions of all Equipment and Protection system. Dimensions Trailer Container for Indoor Equipment (L x W x H) 20 x 3 x 4.6 (m) 4.6 x 3 x 3 (m) The above ratings and dimensions are typical, other systems can be designed upon customer needs and requests. 5
HEAD OFFICE & FACTORY BLB033, Bulebel Industrial Estate, Zejtun ZTN 3000 P.O. Box 20, Paola PLA 1001, Malta. T. (+356) 21693750 - F. (+356) 21693754 - E. info@medelec.com.mt TRIPOLI OFFICE Madaris El Funun W Assanaqa Building 82, Flat 9, 24th December Street, P.O. Box 82118, Tripoli, Libya. T. & F. (+218) 21 4444050 www.medelec-switchgear.com BDTB06-en.2016.10 - Mobile Substation Technical Brochure. We reserve the right to make changes in the course of technical development.