Chapter Quiz. Directions: Write the correct letter on the blank before each question.

Similar documents
TWO FULLY EQUIPPED PUMPERS STATIC AND PRESSURIZED WATER SOURCES REFERENCES: ESSENTIALS OF FIRE FIGHTING, FOURTH EDITION, IFSTA, CHAPTERS 11 AND 12

AIDS LESSON PLAN INSTRUCTOR NOTES INSTRUCTOR GUIDE. Course: Tanker operations in water supply

Tyger Drafting Eductors

Pumping Apparatus Driver/Operator Types of Apparatus Equipped with a Pump. Chapter Test

STANDARD OPERATING GUIDELINES BELMONT COUNTY TANKER TASK FORCE

New Windsor, Maryland Rural Water Supply Drill. Tanker Shuttle Drill May 23, 2009 Summary Report

ESCONDIDO FIRE DEPARTMENT TRAINING MANUAL ENGINE MODULE HOSE PAGE 1 OF 20 Supply Hose Lays Revised

Rural Water Supply Operations Seminar & Drill

ADO-Pumping Apparatus Manipulative Skill Objectives PREVENTIVE MAINTENANCE

LEVEL 2 DEFENSIVE Standard Equipment Guide

Gaining Access. Exploring and alternative to drafting

Water Supply for Suburban and Rural Firefighting, First Edition Final Version December 2012

MEDALLION HYDRANT. clowvalve.com AWWA C502 UL LISTED FM APPROVED NSF 61/372 CERTIFIED 250 PSI WORKING PRESSURE 10-YEAR LIMITED WARRANTY

ADO Mobile Water Supply Apparatus Manipulative Skill Objectives PREVENTIVE MAINTENANCE

ADMIRAL HYDRANT. clowvalve.com

NORTH COUNTY FIRE AUTHORITY POLICY & PROCEDURE MANUAL OPERATIONS

AVK SAUDI VALVES MANUFACTURING COMPANY

NMSU FIRE DEPARTMENT FIRE PUMP ACCEPTANCE TEST

mh-valve.com 129 HYDRANT AWWA C502 NSF 61/372 CERTIFIED UL LISTED FM APPROVED 250 PSI WORKING PRESSURE 10-YEAR LIMITED WARRANTY

STANDARD LEVEL 2 DEFENSIVE Standard Firefighter Training I Minimum Equipment List

Dispatching Apparatus and Personnel

Lakes Region Mutual Fire Aid, New Hampshire Rural Water Supply Operations Seminar & Drill. Tanker Shuttle Drill May 17, 2009 Summary Report

PENNSYLVANIA STATE FIRE ACADEMY PUMPER - DRIVER/OPERATOR (PDO) SKILL STATIONS. Pumper -Driver / Operator (PDO) Skill Stations

Second Revision No. 7-NFPA [ Section No. 2.4 ] Submitter Information Verification. Committee Statement 9/17/2015 2:57 PM

Chapter 15. Fire Hose. Answer Key. Firefighter I

Driver/Operator Program Part III - Tanker

S200-P Series Centrifugal Fire Pumps Operation and Maintenance Instructions

Table of Contents Illustrations

HORRY COUNTY FIRE / RESCUE DEPARTMENT PROUD * PREPARED * PROFESSIONAL STANDARD OPERATING PROCEDURE SOP 715 HYDRANT AND WATER POINT INSPECTIONS

TRAINING BULLETIN APPARATUS P-2 January 22, 1998 FLOWMETERS

Fire Apparatus Driver/Operator Professional Qualifications Mobile Water Supply Apparatus. Skill Station Menu NFPA 1002 Chapters 4 & 10 (2009 Edition)

Rural Water Supply Operations Seminar & Drill

Fire Department Access & Water Supply

HL Series Centrifugal Fire Pumps Operation and Maintenance Instructions

Driver/Operator - Mobile Water Supply

National Fire Protection Association. 1 Batterymarch Park, Quincy, MA Phone: Fax:

Essentials of Fire Fighting

A Dry Hydrant Success Story. How one county maximizes its dry hydrant output

AMERICAN AVK COMPANY AVK SERIES 24 - HIGH PRESSURE, WET BARREL HYDRANT FIELD MAINTENANCE AND INSTRUCTION MANUAL TABLE OF CONTENTS

Data Sheet Issue A

According to AWWA-standard

San Antonio Water System Standard Specifications for Construction ITEM NO. 834 FIRE HYDRANTS

Is Your Fire Department Efficient?

Water Transfer. Performance

THE CO$T OF DOING BU$INE$$

San Antonio Water System Standard Specifications for Construction ITEM NO. 834 FIRE HYDRANTS

June Drill of the Month Instructor Guide. Topic: Review of Hydraulics and Pump Components

County of Yuba Ordinance Requirements for Rural Fire Protection

Operation and Maintenance. S100 Series Centrifugal Fire Pumps. Table of Contents. Visit us at F /22/02 6/21/18

Installation. Installation. 12. System Diagram... 10

INSTRUCTOR GUIDE TOPIC: APPARATUS RESPONSE LEVEL OF INSTRUCTION: TIME REQUIRED: TWO HOURS MATERIALS: APPROPRIATE AUDIO-VISUAL MATERIALS

American Flow control 5 1/4 b-84-b-5

COMMONWEALTH OF KENTUCKY COMMISSION ON FIRE PROTECTION PERSONNEL STANDARDS AND EDUCATION DO-MOBILE WATER SUPPLY COMPETENCY EVALUATION

Relay Pumping Operations

Suction Elbow Flow Performance Tests

Measure South Lane County Fire & Rescue General Obligation Bond November 3, 2015

Table of Contents. Acknowledgments... xii Introduction... 1

AMERICAN FLOW CONTROL 5 1/4 B-84-B-5 FIRE HYDRANT

American Flow control 5 1/4 B-62-B-5

Oconee County Emergency Services Westminster, South Carolina

Big Water Rigs Rescue Engine 703 Rockville VFD Rockville, MD 2008, GBW Associates, LLC Westminster, Maryland

TABLE OF CONTENTS. 3 Outlet Stainless Steel Body. 3 Outlet Ductile Body. 2 Outlet Ductile Body 2 Outlet Bronze Body

Standard Operating Procedure Ottawa Fire Service. Extrication Vehicle Extrication Procedures - Revised

PHILADELPHIA FIRE DEPARTMENT WATER SUPPLY PFD TRAINING MANUAL SUPPLEMENT ENGINE PRACTICES SUPPLEMENT 100 PAGE 1

West Metro Fire Protection District

Day 4 March 17, Multiple Choice Identify the choice that best completes the statement or answers the question.

Bulloch County Fire Department Bulloch County, Georgia. Rural Water Supply Opera;ons Seminar 2- hr Water Supply Drill November 6, 2011 Summary Report

ABL FIRE PROTECTION 300 HOKE STREET RALEIGH, NC

Fire Pump Systems. For the protection of life and property, A-C Fire Pump offers package systems that meet every fire protection need.


Application & Reference Data Typical Specifications. Section 914 Vertical Turbine Fire Pump

Pump Service Testing

Front Suction Flow Test

FIRE PROTECTION PRODUCTS

SECTION (15444) - DOMESTIC WATER PACKAGED BOOSTER PUMPS

Electric Submersible Pumps

High Rise Fire Pumps CM/CGV Series, CMU/CGV Series. Operation and Maintenance

Operation and Maintenance. CG Series Centrifugal Fire Pumps. Illustrations

Fire Engine Information

Background. Vehicle Specifications

FUEL DISPENSING SYSTEMS SE-27. Component Details. 12V DC - 15 GPM Metered Tank-top Dispensing System

HIGH VELOCITY PUMP PUMP END

LAWN SPRINKLER, IRRIGATION PUMP

CLOW CANADA - M-67 HERITAGE BRIGADIER FIRE HYDRANT SPECIFICATION

Figs. 800 Verticle, 800 W. Fig. 800 Vertical Type Fig. 800 W. Wall type.

September 2012 / M&H C502 / Model 129

FIREFLO - MODEL F-06 INSPECTION, INSTALLATION & MAINTENANCE MANUAL. Item No.s/Description

AMERICAN FLOW CONTROL 4 3/4 WATEROUS TREND FIRE HYDRANT

ELECTRIC POLICY INTRODUCTION CHAPTER I GENERAL

Pressure Distribution. Western Canada Onsite Wastewater Management Association

Tanker Off-Load Test: 5,000 gallon Tanker with a 500 gpm Pump

Sentinel 250 Fire Hydrant. Solid design and features to meet any municipal requirement.

ESCONDIDO FIRE DEPT TRAINING MANUAL Section Engine Module Page 1 of 5 Sprinkler System Controls Revised

SECTION FIRE HYDRANTS WITH HYDRANT LOCKS

Maxi-Pump. High capacity centrifugal pump. GEA Farm Technologies - The right choice. GEA Farm Technologies. GEA Farm Equipment Houle

REQUEST FOR PROPOSALS FIRE HYDRANT MAINTENANCE SERVICES

HEAVY-DUTY VALVES. *Limited to Manufacture Defects. Operating Pressure (psi) " Stainless Steel " Polymer

Environmental Standard Operating Procedure (ESOP) Originating Office: Natural Resources and Environmental Affairs (NREA) Office

Chapter 2. The Vehicle-Tank Metering System

Glendale Fire Department

Transcription:

Chapter 12 Quiz Name: Date: Directions: Write the correct letter on the blank before each question. Objective 1: Describe dry-barrel and wet-barrel hydrants. 1. Most fire hydrants are made of: (605) A. PVC. B. steel. C. bronze. D. cast iron. 2. Closing a hydrant too fast may cause a sudden increase in water pressure called: (605) A. water surge. B. water hammer. C. pressure growth. D. pressure increase. 3. Which type of hydrant is installed in areas where prolonged periods of subfreezing weather are common? (605) A. Dry-barrel B. Wet-barrel C. Open-barrel D. Closed-barrel 4. Which type of hydrant is usually installed in warmer climates where prolonged periods of subfreezing weather are uncommon? (607) A. Dry-barrel B. Wet-barrel C. Open-barrel D. Closed-barrel Oklahoma State University 12-1

5. Which type of hydrant has a horizontal compression-type valve at each outlet? (607) A. Dry-barrel B. Wet-barrel C. Open-barrel D. Closed-barrel 6. Which type of hydrant has a main valve located below the frost line that prevents water from entering the hydrant barrel? (605-606) A. Dry-barrel B. Wet-barrel C. Open-barrel D. Closed-barrel 7. The hydrant barrel of a dry-barrel hydrant is usually from the top of the stem down to the main valve. (606) A. open B. closed C. empty D. filled with water 8. When a dry-barrel hydrant is closed after use, the remaining water empties through a: (606) A. drain hole. B. drain plug. C. gate valve. D. butterfly valve. 9. When ensuring that a dry-barrel hydrant is draining correctly, close the main valve by turning the step nut clockwise until resistance is felt, then turn it counterclockwise. (607) A. a quarter-turn B. a full-turn C. two turns C. three turns Oklahoma State University 12-2

Objective 2: Discuss fire hydrant marking and location. 10. According to the NFPA (609), orange fire hydrants indicate a flow of: A. less than 500 gpm (1 900 L/min). B. 500 to 999 gpm (1 900 L/min to 3 780 L/min). C. 1,000 to 1,499 gpm (3 785 L/min to 5 675 L/min). D. 1,500 gpm (5 680 L/min) or greater. 11. According to the NFPA, hydrants indicate a flow of less than 500 gpm (1 900 L/min). (609) A. red B. green C. orange D. light blue 12. According to the NFPA, hydrants indicate a flow of 1,000 to 1,499 gpm (3 785 L/min to 5 675 L/min). (609) A. red B. green C. orange D. light blue 13. According to the NFPA, light blue hydrants indicate a flow of: (609) A. less than 500 gpm (1 900 L/min). B. 500 to 999 gpm (1 900 L/min to 3 780 L/min). C. 1,000 to 1,499 gpm (3 785 L/min to 5 675 L/min). D. 1,500 gpm (5 680 L/min) or greater. 14. Decisions regarding location, spacing, and distribution of fire hydrants are usually made by: (607) A. contractors. B. fire inspectors. C. fire department personnel. D. water department personnel. Oklahoma State University 12-3

15. In general, hydrants should not be spaced more than feet (m) apart in high-value districts. (607) A. 100 (30) B. 200 (60) C. 300 (100) D. 400 (120) 16. A basic rule is to locate a hydrant at intersection. (607) A. every B. every other C. every third D. every fifth 17. 18. Intermediate hydrants may be required where distances between intersections exceed feet (m). (607-608) A. 50 to 100 (15 to 30) B. 250 to 300 (75 to 100) C. 350 to 400 (105 to 120) D. 450 to 500 (135 to 150) Which of the following is NOT a factor affecting hydrant location and spacing? (608) A. Building densities B. Types of construction C. Types of occupancies D. Amount of pedestrian traffic Objective 3: Summarize potential problems to look for when inspecting fire hydrants. 19. Hydrant testing and inspections are the responsibility of: (608) A. NFPA. B. fire department personnel. C. Underwriters Laboratories (UL). D. street department personnel. Oklahoma State University 12-4

20. Which of the following is NOT something to look for when inspecting fire hydrants? (608-609) A. Painted hydrants B. Missing outlet caps C. Outlets that face the wrong direction D. Insufficient distances between buildings and hydrants Objective 4: Explain the process of fire hydrant testing. 21. 22. 23. 24. Which of the following statements about fire hydrant testing is MOST accurate? (609) A. Fire hydrants should be tested on a monthly basis. B. Fire hydrants should be tested on a quarterly basis. C. Fire hydrant testing is always performed by the fire department. D. Many departments are no longer responsible for the testing of hydrants. When conducting a flow test on a hydrant, remove outlet cap(s). (609) A. one B. two C. three D. all After inspecting outlet caps during a flow test, replace all caps except: (609) A. the top outlet cap. B. one 2½-inch (65 mm) cap. C. two 2½-inch (65 mm) caps. D. the outlet cap closest to the pumper. During a flow test, a cap-type pressure gauge should be connected to: (609) A. the pumper. B. the hose nozzle. C. the hydrant to be tested. D. a second hydrant nearby. Oklahoma State University 12-5

25. During a flow test, the test hydrant should be turned on to pressure. (610) A. one-quarter B. half C. three-quarter D. full 26. Residual pressure should be recorded from: (610) A. the pumper. B. the hose nozzle. C. the second hydrant. D. the hydrant to be tested. Objective 5: Discuss alternative water supplies. 27. Which of the following is NOT an alternative water supply source? (610) A. Lakes B. Ponds C. Swimming pools D. Water treatment plants 28. Which of the following is the definition of drafting? (610) A. Drawing water from a pumper to supply a hoseline B. Drawing water from a static source to supply a pumper C. Drawing water from a portable tank to supply a hydrant D. Drawing water from a static source to supply a hydrant 29. A minimum of inches (mm) of water above and below a hard intake strainer is usually needed for it to function properly. (611) A. 12 (300) B. 24 (600) C. 36 (900) D. 48 (1 200) Oklahoma State University 12-6

30. 31. Which kind of strainers can draft water from more shallow sources? (611) A. Intake B. Drafting C. Floating D. Underground Dry hydrants are installed at to increase the water supply available for firefighting. (611) A. static water sources B. water treatment plants C. residential swimming pools D. wastewater treatment facilities 32. Dry hydrants are constructed of: (611) A. copper. B. cast iron. C. aluminum. D. steel or PVC pipe. 33. Dry hydrants are designed to supply at least gpm (L/min). (611) A. 500 (2 000) B. 1,000 (4 000) C. 1,500 (6 000) D. 2,000 (8 000) Objective 6: Discuss rural water supply operations. 34. Which of the following is the definition of a water shuttle? (612) A. Drawing water from a pumper to supply a hoseline B. Drawing water from a static source to supply a pumper C. Hauling water from a portable tank to the fire D. Hauling water from a supply source to portable tanks Oklahoma State University 12-7

35. 36. 37. Water shuttles are recommended for distances greater than mile(s) (km) or greater than the fire department s capability of laying supply hoselines. (612) A. ½ (0.8) B. 1 (1.6) C. 1½ (2.4) D. 2 (3.2) Which of the following is NOT a critical element of a water shuttle? (612) A. Traffic control B. Hydrant operations C. Fast-fill and fast-dump capabilities D. An Incident Commander at both fill and dump sites Which of the following is NOT a key component of a water shuttle? (612) A. Fill apparatus at the fill site B. Vacuum tankers at the fill site C. Attack apparatus at the dump site D. Water tenders to haul water from the fill site to the dump site 38. The dump site of a water shuttle is generally located: (612) A. near the fire or incident. B. near the static water source. C. as close to the station as possible. D. between the fill site and dump site 39. Portable tanks range from gallons (L) upward. (613) A. 250 (1 000) B. 500 (2 000) C. 750 (3 000) D. 1,000 (4 000) 40. Portable tanks may use to transfer water from one tank to another. (613) A. drain fittings B. discharge lines C. hard sleeve hose D. jet siphon devices Oklahoma State University 12-8

41. Which of the following is NOT a way in which water tenders unload? (615) A. Jet dumps B. Relay pumps C. Apparatus-mounted pumps D. Gravity dumping through large dump valves 42. According to NFPA 1901, water tenders on level ground should be capable of dumping or filling at rates of at least gpm (L/min). (615) A. 250 (1 000) B. 500 (2 000) C. 750 (3 000) D. 1,000 (4 000) 43. 44. Which of the following may be used when the water source is close enough to the fire scene that water shuttles are not necessary? (616) A. Relay pumping B. Water shuttles C. Gravity dumps D. Jet siphon devices Which of the following is NOT a factor in determining how many pumpers are needed for a relay? (616) A. Size of hose available B. Volume of water needed C. Amount of hose available D. Distance between the station and the fire scene 45. Which apparatus should be located at the water source? (616) A. Apparatus with largest gravity dump B. Apparatus with largest portable tank C. Apparatus from nearest fire department D. Apparatus with greatest pumping capacity Oklahoma State University 12-9