STAINLESS STEEL VALVES AND ACCESSORIES

Similar documents
ACCESSORIES FOR AIR VALVES & AIR SYSTEMS

B SERIES. Bulletin B-2017

Bulletin H-Tech 03 High Pressure Valves Series H

Modular Air Package. Bulletin VMAP-15.

SERIES C TYPE VALVES C3 VALVES Port Sizes: Four-Way 5/ UNF or M5 Pneumatic-vacuum to 115 psi (8 bar) (individual valves) Gang mounting (2 or mo

AUTOMATION CONTROL VALVES COMPONENTS FOR PROCESS CONTROL

DIECT MOUNT CTUTO VLVES LUMINUM CONSTUCTION SEIES C5 NMU General Description The Versa C5 NMU mount control valve is a high flow, 5-port, solenoid/pil

CONDENSED CATALOG CC

Versa exercises diligence to assure that information contained in this catalog is correct, but does not accept responsibility for any errors or omissi

ACCESSORIES FOR AIR VALVES & AIR SYSTEMS

ACCESSORIES FOR AIR VALVES & AIR SYSTEMS

Versa exercises diligence to assure that information contained in this catalog is correct, but does not accept responsibility for any errors or omissi

AIR PREPARATION. Filters & Regulators 316 Stainless Steel. Bulletin AP

The H Series Leak-Proof, High-Pressure Valves Versa Products Company has been supplying high quality pneumatic and hydraulic directional control valve

CONDENSED CATALOG CC

SOLENOID VALVES FOR PROCESS CONTROL INDUSTRIES AIR VALVES FOR INDUSTRY SINCE 1949

ICO2S - 2/2, 3/2 or 5/2 Exia poppet valves Electromagnetically actuated, solenoid pilot operated

Control & Power, Inc

FITTINGS CHEST FITTINGS CHEST. Get organized with the Pneuforce Fittings Chest!

Easytork Solenoid Valve IOM

Engineering Information. Solenoid Valves Principles of Operation. Solenoid Valves. Direct Acting Valves (Figures 1A, 1B)

Type 2511/12. Type Type 2030 Cable plug. ASI cable plug. Dosing control. General technical data Orifice Type 6518

3/2-, 5/2- and 5/3-way Solenoid Valves for process pneumatics

% ^ ) 4/2 SERIES. Direct Mount. Direct Acting Direct Mount Pilot Valves. Brass or Stainless Steel Bodies 1/4" NPT. Features. Construction.

3/2-, 5/2- and 5/3-way Solenoid Valves for process pneumatics

Mini 1. Compact High Flow 3-Way and 4-Way Pneumatic Directional Control Valves

3 Way/2 Position Valves

V82 series - Redundant valve manifold systems - Compact 1oo2 Safety, 2oo2 Availability and 2oo3 Safety and Availability

Poppet Valves Series. Keeping the World Flowing

3/2-way Small Solenoid Valve, G 1/8 - G 1/4 and sub-base

% # ) Air and Inert Gas Intrinsically Safe Valves 2/2 3/2 4/2 5/2 5/3 SERIES. Brass, Aluminum, or Stainless Steel Bodies 1/4" to 1" NPT

2oo2 with bypass valve exhaust guards and indicators. 2oo2 I4. N/en

SKINNER Intrinsically Safe Series Four-Way

3/8 & 1/2 NPT. 4-Way - 5 Ported - 2 Position - Type 2 Use on all 4 Way - 2 Position applications

Port Flow Rate/ Function Series Actuators Page Number Size Factor

Miniature I/P, E/P Transducer

3/2, 5/2, 5/2 bistable and 5/3 way pneumatic solenoid valve

C-316 SERIES. Bulletin C

% # ) Intrinsically Safe & Non-Incendive Field Wiring Valves Aluminum, Brass, or Stainless Steel Bodies 1/4" to 1" NPT

97100 Inline 3/2, 5/2 & 5/3 spool valves electromagnetic actuated, indirectly controlled G 1/4, 1/4 NPT

SERIES V & T VALVES AIR VALVES FOR INDUSTRY SINCE 1949

Direct-acting 3/2 way plunger valve

TECHNICAL BULLETIN. Logix 510si Series Digital Positioner. Experience In Motion FCD LGENTB /09

3/8 & 1/2 NPT. with 3/8 and 1/2 NPT ports for 4 Way - 2 & 3 Position see Pg locate counterbores in body to control static squeeze on seals.

Maximum Line Resistance vs. Length of Wire Max. Loop Resistance. Max. Wire Run 18AWG 7x26 Stranded (ft)

V200 Positioner. V200 P Pneumatic Positioner. V200 E Electropneumatic Positioner. Housing Material: Cast aluminium with polyester coating

Operating pressure (bar) kv factor (m 3 /h) *3)

Series 1, 2 & 6 Options selector. Port 4 = 1/8" NPT 5 = 1/4" NPT (Series 6* only) 7 = #10-32 UNF 8 = 1/4-28 UNF

Control Valve Specifications

Stainless Steel Pilot Piston Solenoid Valve 2MS Series for High Temperature & High Pressure

Function. Orifice (mm) NBR (Perbunan) 0 EPDM 1 FKM (Viton) 2 FFKM (Kalrez) / O-ring FKM 4

Type Installation, Operation and Maintenance Instructions. Ordering Information. Contents CA20 -

97105 Inline. Ordering information. Technical data. Accessories See page 5

Field IT Actuators & Positioners Electro-Pneumatic Converters I/P Signal Converters Standard Model with Booster Stage

Deep Well Pump Control Valve

PROCESS & AUTOMATED VALVES

4V130P-430P SERIES AIR PILOT VALVE

97100 NAMUR. Technical data

Miniature I/P, E/P Transducer for Electronic Air Pressure Control

Material pressure (bar) (Cv (US) kv x 1,2 Seat

COILS, CONNECTORS, SOLENOID VALVES

2/2 or 3/2-way Solenoid Valve, with pivoted armature and isolating diaphragm

Offshore and Onshore Applications Lucifer TM 2/2 and 3/2 ways 316L Stainless Steel solenoid valves

Series VP4 50/4 70. Large Size 5 Port Solenoid Valve Rubber Seal SJ SY SY SV SYJ SZ VF VP4 S0700 VQ VQ4 VQ5 VQC VQC4 VQZ SQ VFS VFR VQ7 VP4

2-Way/2 Position Valves

Miniature I/P, E/P Transducer for Electronic Air Pressure Control

24010, 3/2 Direct solenoid actuated poppet valve

STC Solenoid Valve List Price

Redundant Control System

Flow. group *2) G1/4 1, , B G1/ , B /4 NPT , B N/en

Solenoid Valves & Accessories. Cylinder Control Bases. Features. Performance Data. Materials

ELECTRONIC CONTROLLER

26230, NAMUR 3/2 & 5/2 Indirect solenoid actuated spool valves

K Series 3 Way Direct Acting Balanced Poppet Solenoid Valve

Series 810: 2 Way Angle Body Valves: 1/4 to 3 NPT

HERION SERIES Indirect solenoid actuated soft seal

3V SERIES SOLENOID VALVE

2/2-way Solenoid Valve with servo diaphragm

Poppet Valves Series

98025 NAMUR/INLINE 3/2 way poppet valves electromagnetic actuated, indirectly controlled G 1/2, 1/2 NPT or flanged with NAMUR Interface

The extendable type 5470 EExi can be used for block modules or for entire valve blocks (tag connectors on top, coil spacing 19 mm).

2/2-way Angle-Seat Valve for medium up to +180 C, threaded port connection, DN 15-65

High Pressure Solenoid Valves

Electrically operated valves Series MF-04 for manifold mounting, 5/2- and 5/3-way G1/8 360 Nl/min (0.366 Cv)

2/2 or 3/2-way Solenoid Valve, with pivoted armature and isolating diaphragm

Electrically operated valves Series BM-01, 3/2-way and 2 x 3/2-way G1/8 550 to 660 Nl/min (0.559 to Cv)

STC E-Series Electrically Actuated Ball Valves 316 Stainless Steel, 2-Way or 3-Way

Actuated Valves PRICING

Kuhnke Technical Data. Contact Details

Product Information ROSS CONTROLS

Pneumatic Power Valves Series 75/76 Manual, Mechanical, Pneumatic and Electric Valves

Control Reliable Double Valves with Total Dynamic Monitoring & Complete Memory

Actuators & Positioners Electro-Pneumatic Converters I/P Signal Converters - TEIP 11 Model without Booster Stage

Electrically operated valves Series M-22, 3/2-, 5/2- and 5/3-way G1/ Nl/min (3.354 Cv)

System 6000 Electropneumatic Converter for Direct Current Signals Type 6116 i/p Converter

深圳市永旭伟业贸易有限公司 SOLENOID VALVES pilot operated, spool type single/dual solenoid (mono/bistable function) stainless steel body, 1/4.

Electrically operated valves Series M-07, 3/2-, 5/2- and 5/3-way G1/ and 1580 Nl/min (1.321 and Cv)

2/2-way Solenoid Valve with servo diaphragm, G 3/8 - G 2

SERIES 740 VALVES PNEUMATIC DIRECTIONAL CONTROL

PROCESS INDUSTRY PNEUMATIC SOLUTIONS

Transcription:

BULLETIN V316-2007 Series V-316 STAINLESS STEEL VALVES AND ACCESSORIES www.versa-valves.com

MODULAR CONCEPT Versa exercises diligence to assure that in formation contained in this catalog is correct, but does not accept responsibility for any errors or omissions. Versa also reserves the right to change or delete data or products at any time without prior notification. To be sure the data you require is correct, consult factory. VAG-4522-316-181DE-XX-(specify voltage) The V-316 Valve Series provides a full range of control valves suited to the most demanding of applications. Ruggedly constructed, both internally and externally, of stainless steel, these valves are able to withstand the physical abuse of corrosive environments and controlled media. A modular design concept utilizing three basic sub-assemblies: a Body Assembly and two Actuator Assemblies (active or passive), simplifi es circuit planning while affording almost unlimited combination possibilities. Port sizes are 1/4 NPT, 3/8 NPT and 1/2 NPT in three-way (3/2, 3/3), and four-way (5/2 and 5/3) styles. Actuation types include manual (hand lever, palm button, latching detent & manual reset), pilot (pressure pilot, diaphragm pilot, air-latch pilot), and solenoid-pilot (including several approved hazardous service types). Solenoid-Pilot Actuator Manual Actuator G -XX Sub-Assembly Nr.: SA-4322-84-316-XX (specify voltage) A -181DE Sub-Assembly Nr.: CA-4302-65-316-181DE Body Assembly 4522 Sub-Assembly Nr.: SA-4522-71-316 Spring Return Actuator S Sub-Assembly Nr.: SA-4302-65-316 Other functions can be easily accomplished as shown with these Pilot and Spring Return actuators. This Bulletin only gives the Actuator Sub-Assemblies and Body Sub-Assemblies. This gives the design engineer maximum versatility as these modules can be combined to complete valves with functions as needed. Pilot Actuator P Sub-Assembly Nr.: SA-4302-64-316 2.1

TECHNICAL DATA MATERIALS: Metal Parts: 316 stainless steel (except solenoid parts, ask factory) conforms to NACE standard MR-01-75. Hand Knob: plastic PRESSURES: Seals: FKM (Fluorocarbon) is standard. Exceptions: diaphragm-pilot seal is NBR (Buna N) or with suffix -31 Teflon coated Buna N; other seal materials are available. See TEMPERATURES/SEALS below. Valve type Pneumatic* VALVE BODY (inlet/system) Manual or Pilot Standard Seals Single Solenoid EXPilot (2-position) Standard Seals Double Solenoid EXPilot (2-position) Standard Seals Double Solenoid EXPilot (3-position) Standard Seals Single Solenoid INPilot (2-position) Standard Seals Double Solenoid INPilot (2-position) Standard Seals Double Solenoid INPilot (3-position) Standard Seals PILOT (signal) Some restrictions concerning maximum pressures may apply. See specific actuator. Pilot (2-position VSP or 3-position VJJ ) Pilot (2-position VPP ) Diaphragm (2-position VSW or 3-position VYY ) Diaphragm (2-position VSW or 3-position VYY ) w/suffix -31 Diaphragm (2-position VWW ) Diaphragm (2-position VWW ) w/suffix -31 Solenoid EXPilot (2-position VSG or 3-position VXX ) Solenoid EXPilot (2 position (VGG ) psi bar (Mpa = bar ) 10 Vacuum to 200 Vacuum to 14 40 to 175 20 to 175 40 to 175 40 to 200 20 to 200 10 to 50 10 to 200 5 to 50 5 to 200 40 to 175 20 to 175 2.8 to 12 1.4 to 12 2.8 to 12 2.8 to 14 1.4 to 14 0.7 to 3.4 0.7 to 14 0.34 to 3.4 0.34 to 14 2.8 to 12 1.4 to 12 Notes: When application involves temperatures below freezing or when shifting intervals are relatively long, it is recommended that suffix -S be specified for valves with spring actuation. Minimum pilot pressure must be increased by 40%. Notes: The following suffixes include the use of suffix -S in all cases: -181AAE, -181CE, -181DE, -3358AE, -3358E. *Consult factory for hydraulic service. TEMPERATURES/SEALS: The table below lists suggested suffix options for various temperature ranges and/or types of service. For temperatures or conditions not listed, consult factory. Type of Service Temperature Range Intermittent Duty Service Continuous Duty Service (Medium/Ambient Temperature) AC or DC AC DC Coil Solenoid Plunger Coil Solenoid Plunger Coil Solenoid Plunger 150ºF to 200ºF (65ºC) (95ºC) 120ºF to 150ºF (50ºC) (65ºC) -10ºF to 120ºF (-23ºC) (50ºC) Suffix -HT Standard Suffix -3 (may be inclusive in other suffix options as it is in -HT) Suffix -3 (may be inclusive in other suffix options) Suffix -HT Standard Suffix -3 (may be inclusive in other suffix options as it is in -HT) Suffix -3 (may be inclusive in other suffix options) Standard Standard Standard Suffix -3 (may be inclusive in other suffix options) Suffix -HT Suffix -HT Standard Suffix -3 (may be inclusive in other suffix options as it is in -HT) Suffix -3 (may be inclusive in other suffix options as it is in -HT) Suffix -3 (may be inclusive in other suffix options) FLOW CALCULATION: Air Flow = f (p1-p2)(p2) (T)(SG) English Metric Air flow SCFM Nm 3 /h f = Conversion factor 22.5 Cv 30.8 Kv p1 = Upstream pressure p1 - p2 < 0.5 p2 p2 = Downstream pressure psi absolute bar absolute T = Temperature upstream absolute 460º + Fº 273º + Cº SG = Specific gravity 1.0 1.0 FLOW: Note: 0.59 SCFM = 1 Nm 3 /h 14.5 psi = 1 bar Port Size of Valve Body For details see page 8.1 through 8.6 1/4 NPT 3/8 NPT 1/2 NPT Flow Diameter inch mm 3/8 9.5 3/8 9.5 5/8 16.0 Flow Factor Cv Kv 1.8 26 2.0 29 5.5 80 3.1

TECHNICAL DATA ELECTRICAL: Solenoid-Pilot actuated V316 valves are available with a variety of different solenoids for both nonhazardous and hazardous locations. Basic details of these actuators are listed below. Dimensions, product numbers, and other details may be found on pages 5.1 through 5.6. For additional data consult factory. NON HAZARDOUS LOCATION SOLENOIDS Suffix Identification Protection Classification Area Classification and (Gas Grouping) Certification- (Conformance) -U General Purpose Indoor & Outdoor CSA NEMA 1, 2, 3 Ingress Protection -HC -U General Purpose Indoor & Outdoor CSA NEMA 4; IP65 per IEC 529 HAZARDOUS LOCATION SOLENOIDS Suffix Identification Protection Classification Area Classification and (Gas Grouping) Certification- (Conformance) Ingress Protection -XX Page 5.3 Hazardous Locations Class I, Division 2 (A & B) Class I, Division 1 (C & D) Class II, Division 1 (E, F, & G) UL CSA NEMA 7 & 9 -LB-XX Hazardous Locations Class I, Division 2 (A & B) Class I, Division 1 (C & D) Class II, Division 1 (E, F, & G) UL CSA NEMA 7 & 9 Page 5.4 -XN (d) Flameproof Zones 1 and 2 (IIB+H 2) Category 2G T4 ATEX IP66 Page 5.3 -LB-XN (d) Flameproof Zones 1 and 2 (IIB+H 2) Category 2G T6 ATEX IP66 Page 5.4 -XDAS or -XDAT Page 5.3 (d) Flameproof Zones 1 and 2 (IIC) Category 2G ATEX IP66 and IP67 -XMAA or -XMAE or -XMAF or -XMAG Page 5.5 (m) Encapsulation (e) Increased Safety Zones 1 and 2 (II) Category 2G ATEX IP66 and IP67 -XMFA or -XMFE or -XMFF or -XMFG Page 5.5 (m) Encapsulation (e) Increased Safety Zones 1 and 2 (II) Category 2G ATEX IP66 and IP67 -HC-XISC -HCC-XISC Hazardous Locations Class I, Groups (A, B, C & D) Class II, Groups (E, F & G) Class III, Division 1 Factory Mutual CSA NEMA 4 Page 5.6 -HC-XISX6 -HCC-XISX6 (ia) Intrinsic Safe Zones 0, 1 and 2 (IIC) Category 1G ATEX IP65 T6 Page 5.6 -XIFA or -XIFE or -XIFF (ib) Intrinsic Safe Zones 1 and 2 (IIB) Category 1G ATEX IP66 and IP67 Page 5.6 3.2

PRODUCT NUMBER COIL CODES: Complete product numbers require, when applicable, a coil code that represents the desired coil current type, frequency and voltage. The coil code takes the form shown below, with ratings and voltage substituted as required. Rating Code A = 60Hz frequency D = Direct Current (DC) E = 50Hz frequency Voltage (Power) All usual 50 Hz & 60 Hz AC (6W) All usual DC (7W) 24V60, 120V60, 240V60 (8.5W) 24V50, 110V50, 220V50 (8.5W) 12VDC, 24VDC, 48VDC (10.5W) Voltage (Indicated by three digits: as example, 24 volts = 024 120 volts = 120.) Electrical Characteristics Class F epoxy molded coil (155ºC). Continuous duty 2 leads 24 (60 cm). Class F epoxy molded coil (155ºC), with 3 spade terminals and mini DIN socket with PG9 cable gland. Continuous duty. Miscellaneous Steel cover with 1/2 NPT conduit entry. Page 5.1 Page 5.1 Voltage (Power) All usual 50 Hz & 60 Hz AC (5.6W) All usual DC (7.2W) 12V60, 24V60, 48V60, 120V60, 240V60 (1.8W) 6VDC, 12VDC, 24VDC, 48VDC (1.8W) All usual 50 Hz & 60 Hz AC (5.6W) All usual DC (7.2W) 12V60, 24V60, 48V60, 120V60, 240V60 (1.8W) 6VDC, 12VDC, 24VDC, 48VDC (1.8W) 24V50, 230V50 (6W); 127V50 (10W) 24V60, 120V60, 240V60 (10W) 12VDC, 24VDC, 28VDC, 48VDC, 110VDC, 125VDC (10W) 24VDC (4W) (Consult factory for other voltage options) Electrical Characteristics Class F epoxy molded coil (155ºC). Continuous duty. 3 leads 24 (60 cm). Class F epoxy molded coil (155ºC). Continuous duty. 3 leads 24 (60 cm). Class F epoxy molded coil (155ºC). Continuous duty. 3 leads 24 (60 cm). Class F epoxy molded coil (155ºC). Continuous duty. 3 leads 24 (60 cm). Class F epoxy molded coil (155ºC). Continuous duty. Continuous duty. Coil & Rectifi er, including surge suppression, potted within housing. Miscellaneous Steel chromate coated coil housing with 1/2 NPT conduit entry. For stainless steel (182FM) coil housing add: (-ST) Steel chromate coated coil housing with 1/2 NPT conduit entry. For stainless steel (182FM ) coil housing add: (-ST) Maximum pilot pressure 120 psi (8 bar). 1.8W nominal power. Steel chromate coated coil housing with M20 x 1.5 conduit entry. Ground terminal on cover. For stainless steel (182FM) coil housing add: (-ST) Steel chromate coated coil housing with M20 x 1.5 conduit entry. Ground terminal on cover. For stainless steel (182FM) coil housing add: (-ST) Maximum pilot pressure 120 psi (8 bar) 1.8W nominal power. Stainless steel coil housing with internal Junction Box. Internal and external ground screw. M20 x 1.5 conduit entry: (-XDAS) 1/2 NPT conduit entry: (-XDAT) Thick wall epoxy coil housing with integral junction box. Internal ground terminal. M20 x 1.5 conduit entry: (-XMAA) Cable gland for 6-12 mm ø cable: (-XMAE) 1/2 NPT conduit entry with adapter: (-XMAF) Cable gland for 9-16 mm ø cable: (-XMAG) 24VDC (10W inrush, 2.6W holding) (Consult factory for other voltages) Continuous duty. Coil & Power Controller potted within housing. Thick wall epoxy coil housing with integral junction box. Internal ground terminal. M20 x 1.5 conduit entry: (-XMFA) Cable gland for 6-12 mm ø cable: (-XMFE) 1/2 NPT conduit entry with adapter: (-XMFF) Cable gland for 9-16 mm ø cable: (-XMFG) 24VDC system voltage prior to barrier (1.6 watt max.) 24VDC system voltage prior to barrier (1.6 watt max.) 24VDC (0.8W) (Consult factory for other voltages) Class F epoxy molded coil (155ºC). Continuous duty. Class F epoxy molded coil (155ºC). Continuous duty. Continuous duty. Coil and power controller potted within housing. Requires the use of an approved barrier or isolator. Maximum operating system voltage before barrier 28VDC. Maximum pilot pressure 115 psi (8 bar). 3 spade terminals & DIN connector with PG9 cable gland: (-HC) 1/2 NPT conduit entry: (-HCC) Requires the use of an approved barrier or isolator. Maximum operating system voltage before barrier 28VDC. Maximum pilot pressure 115 psi (8 bar). 3 spade terminals & DIN connector with PG9 cable gland: (-HC) 1/2 NPT conduit entry: (-HCC) Requires the use of an approved safety barrier or isolator. Thick wall epoxy coil housing and integral junction box. Internal ground terminal. M20 x 1.5 conduit entry: (-XIFA) Cable gland for 6-12 mm ø cable: (-XIFE) 1/2 NPT conduit entry with adapter: (-XIFF) 3.3

3.4 Each letter and digit in the product number of a Versa Valve has a signifi cant meaning, as explained below. Letters or numbers shown in black in the example below do not change. V S P 3 3 0 1 316 Suffix Valve Series Series V-316 Valves Pneumatic Service (Nominal Pressure Range Vacuum to 200 psi (14 bar). Some restrictions apply. See specific actuators.) ACTUATING DEVICES At left end of At right end of valve valve when looking at inlet port of body* A B G I J L N P R S U Combination - or Special Actuator Spring centering (for 3 position manually operated valves) Solenoid-pilot Hand Button (for panel mounting) Pilot-Spring Centering Hand-Lever Non-return end-cap Pressure-Pilot Reverse Spring Return (spring pulls valve spool) Spring Return (spring pushes valve spool) 3-Position Detent (For 3 position manually operated valves) Function (also see Spool Details) 3* W Diaphragm-Pilot (low pressure-pilot) X Solenoid-Pilot Spring Centering (for 3 position solenoid pilot valves) Y Diaphragm-Pilot Spring Centering (for 3 position Diaphragm-Pilot valves) Z 2-Position Detent (for 2-position manually operated valves) *3-way NC function requires actuator device on right. 3-way NO function requires actuator device on left. Three-Way 3/2 or 3/3 4 Four-Way 5/2 or 5/3 7 Two Outlet (Diverter) 3/2 or 3/3 8 Two Inlet (Selector) 3/2 or 3/3 * Two-Way may be accomplished by plugging the exhaust port of three-way valve bodies Port Size 3 1/4 NPT 4 3/8 NPT 5 1/2 NPT BODY DETAILS Type of Body Sideported EXPilot 0 Body with threaded side-ports (for Manual, Pilot and EX- Pilot solenoid actuated valves) Sideported INPilot 2 Body with threaded side-ports and internal drilling to supply inlet pressure to INPilot act. of Solenoid-pilot Spool Details (flow pattern*) Three-Way 3/2 Valves 1 2 Norm. Closed Norm. Open 2 Two Outlet (See Function column for flow) 2 Two Inlet (See Function column for flow) Three-Way 3/3 Valves 3 4 For 3/3 Two-inlet or Two-outlet see pg. 8.3 Four-Way 5/2 Valves 2 Four-Way 5/3 Valves 3 4 *Left and Right Flow Diagrams indicate 2-position valve. Center Flow Diagram shows 3-position. For other Center Flow patterns, see pages 8.1 thru 8.6 316 indicates that the basic construction material for valve parts is AISI 316 Stainless Steel (Conforms to NACE Standard MR-01-75) Suffix Detail numbers indicate modifications or variations of the basic Valve. When specifying, simply add the Suffix Details required in alphabetical and numerical following order. In this bulletin many Suffix Details are described. For more: see Suffix Detail Product Bulletin, or consult factory. Coil voltages are indicated here. For specific voltage, use coil code number listed on page 3.3. VERSA Series V-316 Valves consist of three Sub-Assemblies: one Body-Assembly and two Actuator-Assemblies, mounted at the LH side and the RH side of the Body. All the Actuators can be mounted at either side, are fully interchangeable and can be combined to suit the function desired. See Pages 4.1 through 8.6 for those Sub-Assemblies. SELECTOR CHART & PRODUCT NUMBERING

PILOT ACTUATORS* Prefi x Suffi x P (PRESSURE) PILOT SA-4302-64-316 PULL TYPE (PRESSURE) PILOT A and -PTP CA-4302-64-316-PTP (PRESSURE) PILOT with Threaded Vent port P and -107E SA-4302-64-316-107E PUSH-PULL (PRESSURE) PILOT A and -PPP CA-4302-64-316-PPP J (PRESSURE) PILOT-SPRING CENTERED (for 3 position pilot operated valves) SA-4302-83-316 AIR LATCH (PRESSURE) PILOT hold function only A and -301E CA-4302-64-316-301E AIR LATCH (PRESSURE) PILOT- PULL TYPE hold function only A and -301RE CA-4302-64-316-301RE *For Pilot Pressure ranges see page 3.1 4.1

PILOT ACTUATORS* Prefi x Suffi x W Y DIAPHRAGM PILOT (for 2 position diaphragm pilot operated valves) SA-4302-87-316 For low pressure pilot signals DIAPHRAGM PILOT- SPRING CENTERED (for 3 position diaphragm pilot operated valves) For low pressure pilot signals SA-4302-88-316 NOTE: Diaphragm piston can be equipped with Tefl on coated Buna N U cup. Add suffi x -31 to complete valve number or sub-assembly number. PILOT-COMBINATION ACTUATORS* (PRESSURE) PILOT-TWO DETENT A and -150E CA-4302-64-316-150E (PRESSURE) PILOT-REVERSE SPRING RETURN A and -159E CA-4302-64-316-159E *For Pilot Pressure ranges see page 3.1 4.2

SOLENOID-PILOT ACTUATORS 2 Position GENERAL SERVICE (NONHAZARDOUS SERVICE) 24 Leads Third Wire Ground Supplied When Requested 1/2-14 NPT Conduit Conn Manual Override (Suffix - ME) VERSA 10-32 UNF Adapter Option 1/8 NPT (Suffix - H2) 125 31.7 1.62 41.3 2.54 64.6.57 14.5 3.00 76.2.69 17.5 2 Position 3 Position 2.11 53.5.94 23.9 1.38 35.1 1/8 NPT Pilot Inlet Port (on EXPilot Valves only) Height dimensions shown are for Nonhazardous solenoids. Dimension for Hazardous solenoids depend upon type of solenoid selected. Suffi x +options: -HT High Temperature Class H coil -H2 adapter with 1/8 NPT thread -L14 Dust Excluder Solenoid Nut -ME manual override -PC potted coil; NEMA 4/4X, IP65-243 wire leads with grommet type housing Prefi x Suffi x SOLENOID PILOT (with threads for conduit connection) G and -U SA-4302-84-316-U-.+.-(**) G and -U SA-4322-84-316-U-.+.-(**) 3 Position GENERAL SERVICE (NONHAZARDOUS SERVICE) 3 Position HAZARDOUS SERVICE Any of the solenoids shown on pages 5.3, 5.4, 5.5, and 5.6 can be used on this actuator. SOLENOID-PILOT SPRING CENTERING (for 3 posiition solenoid operated valves) Available for any of the solenoids and respective options shown on pages 5.1, 5.3, 5.4, 5.5 and 5.6. X and -.U. SA-4302-85-316-.U.-.+.-(**) X and -.U. SA-4322-85-316-.U.-.+.-(**) (**) Specify coil code on page 3.3, to complete number PG-9 Cable Entry Mini DIN Connector Manual Override (Suffix - ME) 2 Position (For 3 Position refer also to drawing at top of page) 1.48 37.7 10-32 UNF 1.62 41.3 Adapter Option 1/8 NPT (Suffix - H2).57 14.5 3.00 76.2.69 17.5 3.62 92.0.94 23.9 1.38 35.1 1/8 NPT Pilot Inlet Port (on EXPilot Valves only) Suffi x +options: -HT adapter with 1/8 NPT thread -L14 Dust Excluder Solenoid Nut -ME manual override 2 Position GENERAL SERVICE (NONHAZARDOUS SERVICE) SOLENOID-PILOT (with DIN type connector-spade terminal coil) G and -HC-U SA-4302-84-316-HC-U-.+.-(**) G and -HC-U SA-4322-84-316-HC-U-.+.-(**) 3 Position (For 3 Position also refer to drawing at top of page) GENERAL SERVICE (NONHAZARDOUS SERVICE) SOLENOID-PILOT SPRING CENTERING (with DIN type connector-spade terminal coil) X and -HC-U SA-4302-85-316-HC-U-.+.-(**) X and -HC-U SA-4322-85-316-HC-U-.+.-(**) (**) Specify coil code on page 3.3, to complete number 5.1

SOLENOID-PILOT COMBINATION ACTUATORS Prefi x Suffi x 2 Position GENERAL (NONHAZARDOUS) OR HAZARDOUS SERVICE SOLENOID-PILOT and REVERSE SPRING RETURN A and -138E-.?.- CA-4302-84-316-138E-.?.-.+.-(**) A and -138E-.?.- CA-4322-84-316-138E-.?.-.+.-(**) Any of the solenoids shown on pages 5.1, 5.3, 5.4, 5.5, and 5.6 can be used on this actuator SOLENOID-PILOT TWO DETENT A and -173E-.?.- CA-4302-84-316-173E-.?.-.+.-(**) A and -173E-.?.- CA-4322-84-316-173E-.?.-.+.-(**) SOLENOID AIR-LATCH PILOT hold function only A and -301GE-.?.- CA-4302-84-316-301GE-.?.-.+.-(**) A and -301GE-.?.- CA-4322-84-316-301GE-.?.-.+.-(**)? Specify suffi x on page 3.2, which solenoid operator is required. + Specify Options (**) Specify coil code to complete number. REDUNDANT SOLENOID ACTUATOR 2 Position GENERAL SERVICE (NONHAZARDOUS) OR HAZARDOUS SERVICE Prefi x Suffi x A A SOLENOID-PILOT and REDUNDANT SOLENOID-PILOT and -RS-.?.- CA-4302-84-316-RS-.?.-.+.-(**) and -RS-.?.- CA-4322-84-316-RS-.?.-.+.-(**)? Specify suffi x on page 3.2, which solenoid operator is required. + Specify Options (**) Specify coil code to complete number. 5.2

SOLENOID-PILOT ACTUATORS 24 Leads 2 Wire w/ground Earthen Ground for -XN 1.52 38.5 1.44 Ø 36.5 Adapter Option 1/8 NPT ( Suffix -- H2 ) 10-32 UNF.57 14.5 2 Position (for 3 Position also refer to Drawing at top of page 5.1) HAZARDOUS SERVICE Prefi x Suffi x SOLENOID-PILOT Hazardous Locations {-XX: UL listed & CSA approved for Hazardous Locations; Class I, Div 2 (A & B); Class I, Div 1 (C & D); Class II, Div 1 (E, F & G).} (d) Flameproof {-XN: ATEX approved; Zones 1 and 2, (IIB + H 2) Category 2G.} G and -XX SA-4302-84-316-XX-.+.-(**) G and -XN SA-4302-84-316-XN-.+.-(**) 1/2-14 NPT (-XX) M20 x 1.5 (-XN) Elect Conn Manual Override (Suffix - ME ) 1.62 41.3 3.08 78.3.69 17.5 2.26 57.4.94 23.9 1.38 35.1 1/8 NPT Pilot Inlet Port ( on EXPilot Valves only ) G and -XX SA-4322-84-316-XX-.+.-(**) G and -XN SA-4322-84-316-XN-.+.-(**) Suffi x +options: -HT High Temperature Class H coil (For UL or CSA approved, consult factory) -H2 adapter with 1/8 NPT thread -L14 Dust Excluder Solenoid Nut -ME -ST -PC manual override #182FM stainless steel coil housing potted coil; NEMA 4/4X, IP65 (**) Specify coil code on page 3.3, to complete number 2.2 56.0 3.35 Ø 85.0 1/8 NPT (Suffix - H2) 1/4 NPT (Suffix - H) G SOLENOID-PILOT (d) Flameproof {-XDAS or XDAT; ATEX approved; Zones 1 and 2, (IIC) Category 2G.} and -XDA* SA-4302-84-316-XDA..*.-.+.-(**) 1/2-14 NPT (XDAT) M20 x 1.5 (XDAS) VERSA PARAMUS NJ - SA APELDOORN THE NETHERLANDS G and -XDA* SA-4322-84-316-XDA..*.-.+.-(**) *Specify identifi cation detail. Detail S: M20 x 1.5 conduit entry T: 1/2 NPT conduit entry 1.37 34.8.59 15.0.69 17.5.61 15.5 1.38 35.0 1/8 NPT Pilot Inlet Port (on EX Pilot Valves only) Suffi x +options: -HT High Temperature Class H coil -H2 adapter with 1/8 NPT thread -H2 adapter with 1/4 NPT thread -303 Varistor for suppression purposes included (**) Specify coil code on page 3.3, to complete number 5.3

SOLENOID-PILOT ACTUATORS 2 Position (for 3 Position also refer to Drawing at top of page 5.1) HAZARDOUS SERVICE SOLENOID-PILOT LOW-WATT TYPE- Nominal Power 1.8W Hazardous Locations {-LB-XX: UL listed & CSA approved for Hazardous Locations; Class I, Division 2 (A & B); Class I, Division 1 (C & D); Class II, Division 1 (E, F & G).} (d) Flameproof {-LB-XN: ATEX approved; Zones 1 and 2, (IIB + H 2 ) Category 2G.} Max pilot pressure 120 psi (8 bar); air only. NOTE: 2 position shown. Refer to Drawing page 5.1 for 3 position. Prefi x Suffi x G and -LB-XX SA-4302-84-316-LB-XX-.+.-(**) G and -LB-XN SA-4302-84-316-LB-XN-.+.-(**) G and -LB-XX SA-4322-84-316-LB-XX-.+.-(**) G and -LB-XN SA-4322-84-316-LB-XN-.+.-(**) X and -LB-XX SA-4302-85-316-LB-XX-.+.-(**) X and -LB-XN SA-4302-85-316-LB-XN-.+.-(**) X and -LB-XX SA-4322-85-316-LB-XX-.+.-(**) X and -LB-XN SA-4322-85-316-LB-XN-.+.-(**) Suffi x +options: -H2 Adapter with 1/8 NPT thread -L14 Dust Excluder Solenoid Nut -ME Manual Override -ST #182 FM stainless steel coil housing (**) Specify coil code on page 3.3, to complete number 5.4

SOLENOID-PILOT ACTUATORS 2 Position (for 3 Position also refer to Drawing at top of page 5.1) HAZARDOUS SERVICE Prefi x Suffi x 1/8 NPT (Suffix - H2) 1/4 NPT (Suffix - H) SOLENOID-PILOT (m) Encapsulation, (e) Increased Safety {-XMA*: ATEX approved; Zones 1 and 2, (II) Category 2G.} Max. pilot pressure 175 psi [12 bar].75 19.1 G and -XMA* SA-4302-84-316-XMA*-.+.-(**) RSA Manual Override (Suffix -ME) 1.62 41.3 ADAPTER: 1/2 NPT (-XMAF) CABLE GLAND.69 17.5 (M20 X 1.5) (-XMAA) (-XMAE & -XMAG) 1.38 35.1 RSA USA RN NL.94 23.9 1/8 NPT Pilot Inlet Port (on EXPilot Valves only) G and -XMA* SA-4322-84-316-XMA*-.+.-(**) *Specify identifi cation detail. Detail A: M20 x 1.5 conduit entry. E: Cable gland for 6-12mm ø cable F: 1/2 NPT conduit entry with adapter. G: Cable gland for 9-16 mm ø cable Suffi x +options: -H Adapter with 1/4 NPT thread -H2 Adapter with 1/8 NPT thread -L14 Dust Excluder Solenoid Nut (**) Specify coil code on page 3.3, to complete number. SOLENOID-PILOT (m) Encapsulation, (e) Increased Safety {-XMF*: ATEX approved; Zones 1 and 2, (II) Category 2G.} Max. pilot pressure 175 psi [12 bar ] 1/8 NPT (Suffix - H2) 1/4 NPT (Suffix - H).75 19.1 G and -XMF* SA-4302-84-316-XMF*-.+.-D024 RSA Manual Override (Suffix -ME) 1.62 41.3 ADAPTER: 1/2 NPT (-XMFF) CABLE GLAND (M20 X 1.5) (-XMFA).69 17.5 RSA USA RN NL.94 23.9 (-XMFE & XMFG) 1.38 35.1 1/8 NPT Pilot Inlet Port (on EXPilot Valves only) G and -XMF* SA-4322-84-316-XMF*-.+.-D024 *Specify identifi cation detail. Detail A: M20 x 1.5 conduit entry. E: Cable gland for 6-12mm ø cable. F: 1/2 NPT conduit entry with adapter. G: Cable gland for 9-16mm ø cable. Suffi x +options: -H Adapter with 1/4 NPT thread -H2 Adapter with 1/8 NPT thread -L14 Dust Excluder Solenoid Nut 5.5

SOLENOID-PILOT ACTUATORS 2 Position (for 3 Position also refer to Drawing at top of page 5.1) HAZARDOUS SERVICE PG-9 Cable Entry -HC (1/2 NPT conduit entry -HCC) ISO Connector Manual Override (Suffix -ME) Can be rotated through 360 1.69 43.0 1.62 41.3 M5 Threaded EXH Port Torque setting for tightening nut at assembly is 12 lbf - in (1.4 Nm) 2.82 71.6.69 17.5 3.33 84.6.94 23.9 1.38 35.1 1/8 NPT Pilot Inlet Port (on EXPilot Valves only) Prefi x Suffi x SOLENOID-PILOT Hazardous Locations {-HC-XISC or HCC-XISC: Factory Mutual & CSA approved; Class I, Groups (A, B, C, & D); Class II, Groups (E, F, & G); Class III, Div. 1)} (ia) Intrinsic Safe {-HC-XISX6 or HCC-XISX6: ATEX approved; Zones 0, 1 & 2; (IIC) Category 1G} Approved Safety Barrier or isolator required. Max. pilot pressure 115 psi [8 bar]. G and -*-XISC SA-4302-84-316-*-XISC-.+.-D024 G and -*-XISX6 SA-4302-84-316-*-XISX6-.+.-D024 G and -*-XISC SA-4322-84-316-*-XISC-.+.-D024 G and -*-XISX6 SA-4322-84-316-*-XISX6-.+.-D024.75 19.1 1/8 NPT (Suffix - H2) 1/4 NPT (Suffix - H) RSA RSA USA RN NL *Specify identifi cation detail. Detail -HC: 3 spade terminals and mini DIN connector with PG9 cable gland -HCC: 1/2 NPT conduit entry Suffi x +options: -H2 Adapter with 1/8 NPT thread -ME Manual Override -L14 Dust Excluder Solenoid Nut SOLENOID-PILOT (ib) Intrinsic Safe {-XIF*: ATEX approved; Zones 1 & 2; (IIB) Category 1G} Approved Safety Barrier or isolator required. Max. pilot pressure 175 psi [12 bar] M20 X 1.5 (XIFA).94 23.9 G and -XIF* SA-4302-84-316-XIF*-.+.-D024 Manual Override (Suffix -ME) 1.62 41.3 1/2 NPT (XIFF) CABLE GLAND (XIFE).69 17.5 1.38 35.1 1/8 NPT Pilot Inlet Port (on EXPilot Valves only) G and -XIF* SA-4322-84-316-XIF*-.+.-D024 *Specify identifi cation detail. Detail A: M20 x 1.5 conduit entry. E: Cable gland for 6-12mm ø cable. F: 1/2 NPT conduit entry with adapter. Suffi x +options: -H Adapter with 1/4 NPT thread -H2 Adapter with 1/8 NPT thread -L14 Dust Excluder Solenoid Nut 5.6

MANUAL ACTUATORS Prefi x Suffi x I HAND BUTTON SA-4302-86-316 HAND BUTTON with 2 Panel Nuts I and 43E SA-4302-86-316-43E (Reduces max. panel thickness from 0.90 to 0.58) HAND BUTTON With Protective Boot I and -NV93E SA-4302-86-316-NV93E I and -LOV*E HAND BUTTON With Lockout Provision *Specify identifi cation detail. Detail B: Lockout in exhaust position only SA-4302-86-316-LOVBE E: Lockout in either offset position SA-4302-86-316-LOVEE L HAND LEVER (with protective boot) SA-4302-69L-316 6.1

MANUAL COMBINATION ACTUATORS Prefi x Suffi x HAND BUTTON and REVERSE SPRING RETURN (Push to operate) A and -136E CA-4302-86-316-136E HAND BUTTON and SPRING RETURN (Pull to operate) A and -136PE CA-4302-86-316-136PE A HAND BUTTON and REVERSE SPRING RETURN with MANUAL LATCH (Push to operate) and 136DRE CA-4302-86-316-136DRE A HAND BUTTON and SPRING RETURN With MANUAL LATCH (Pull to operate) and 181DRE CA-4302-86-316-181DRE NOTE: Both actuator types with manual latch, listed above, can be provided with a protective boot per detail shown. Indicate by using suffi x -294 in addition to all other suffi x designations. HAND LEVER and SPRING RETURN with LATCHING DETENT And MANUAL RESET A and -181CE CA-4302-65-316-181CE Latches automatically when valve spool has been shifted on signal or manually against the spring. Unlatching allows the spring to return the valve spool automatically. A and -181DE CA-4302-65-316-181DE Unlatching allows valve spool to be shifted manually or on signal. Spring returns valve spool automatically when signal is removed, and valve latches. Note: Other latching sequences are available, consult factory for details. 6.2

RETURN AND NON-ACTIVE DEVICES Prefi x Suffi x SPRING RETURN and LATCHING DETENT A and -3358E CA-4302-65-316-3358E Unlatching allows valve spool to shift on signal. Spring returns valve spool automatically when signal is removed, and valve latches. A and -3358AE CA-4302-65-316-3358AE Latches automatically when valve spool shifts on signal. Unlatching allows the spring to return valve spool automatically. N R S B NON-RETURN SA-4302-71-316 (Empty cap for manually operated valves or where combination actuators are used on one end of valve) REVERSE SPRING RETURN SA-4302-70-316 (Spring pulls valve spool for manually operated or pull type pilot valves) SPRING RETURN SA-4302-65-316 (Spring pushes valve spool for all valves except pull type pilot and valves with combination actuators on one end of valve) SPRING CENTERING SA-4302-72-316 (For 3 position manually operated valves) U Z THREE-DETENT SA-4302-81-316 (For 3 position manually operated valves) TWO-DETENT SA-4302-82-316 (For 2 position manually operated valves) PLAIN END-CAP A and -33E CA-4302-32-316-33E For position indication of valves with hand combination actuator on other end of valve. Also for tandem mounting of valves; a connector (for coupling of valve spools) and a mounting plate (for correct alignment of valves) can be supplied. 7.1

*THREE-WAY (3 port-2 position & 3 port-3 position) BODY ASSEMBLIES *Two-way function may be provided by plugging the exhaust port (EA or 1) of Three-way Body Assembly. Body Assemblies with 2-outlet or 2-inlet function, see page 8.3. 1/4 NPT & 3/8 NPT **3/2 (three-port 2-position) BODY ASSEMBLY -3301- SA-3301-62-316 1/4 NPT -3401- SA-3401-72-316 3/8 NPT **Body Assemblies for NC and NO functions are identical. For NC function the Return Device should be mounted at the LH side ; for NO function at the RH side. -3302- -3402- * * 3/3 (three-port 3-position) BODY ASSEMBLY -3303- SA-3303-62-316 1/4 NPT -3403- SA-3403-72-316 3/8 NPT Dimensions for 3/3 (Three-Port 3-position) Body Assemblies are the same as for 2-position Body Assemblies shown above. -3304- SA-3304-62-316 1/4 NPT -3404- SA-3404-72-316 3/8 NPT NOTE: Product number designations and subassembly numbers that are listed are for EXPilot type valves; for INPilot type valves the third digit 0 is exchanged for 2. 8.1

*THREE-WAY (3 port-2 position & 3 port-3 position) BODY ASSEMBLIES *Two-way function may be provided by plugging the exhaust port ( EA 1 ) of Three-way Body Assembly. Body Assemblies with 2-outlet or 2-inlet function, see page 8.4. 1/2 NPT **3/2 (three-port 2-position) BODY ASSEMBLY -3501- SA-3501-72-316 1/2 NPT **Body Assemblies for NC and NO functions are identical. For NC function the Return Device should be mounted at the LH side ; for NO function at the RH side. 3/3 (three-port 3-position) BODY ASSEMBLY -3503- SA-3503-72-316 1/2 NPT Dimensions for 3/3 (Three-Port 3-position) Body Assemblies are the same as for 2- position Body Assemblies shown above. -3504- SA-3504-72-316 1/2 NPT NOTE: Product number designations and subassembly numbers that are listed are for EXPilot type valves; for INPilot type valves the third digit 0 exchanged for 2. 8.2

TWO-INLET or TWO-OUTLET FUNCTION (3/2 & 3/3) BODY ASSEMBLIES 1/4 NPT & 3/8 NPT LH side RH side.656 16.7.265 Ø 2 HOLES IN 2 N.J., USA & Netherlands OUT 3 OUT 3 VERSA.797 20.2.797 20.2 2.00 50.8 3/2 (three-port 2-position) BODY ASSEMBLY 1.09 27.8 1/4 NPT or 3/8 NPT 3 PORTS -7302- SA-7302-62-316 1/4 NPT 2.19 55.6-7402- SA-7402-72-316 3/8 NPT.75 19.1 1.00 25.4 1.50 38.1.656 16.7.265 Ø 2 HOLES OUT 2 N.J., USA & Netherlands IN 3 IN 1.797 20.2.797 20.2 2.00 50.8-8302- SA-8302-62-316 1/4 NPT 1.09 27.8 1/4 NPT or 3/8 NPT 3 PORTS 2.19 55.6-8402- SA-8402-72-316 3/8 NPT.75 19.1 1.00 25.4 1.50 38.1 1/4 NPT =.66 16.7 3/8 NPT =.62 15.8 Dimensions for 3/3 (Two-Inlet & Two-Outlet) Body Assemblies are the same as for 2-position Body Assemblies shown above. 3/3 (three-port 3-position) BODY ASSEMBLY Body Assemblies with 3-position function: change fourth digit 2 in sub-assembly number into 3 for all ports blocked in center position. NOTE: Product number designations and subassembly numbers that are listed are for ExPilot type valves; for INPilot type valves the third digit 0 is exchanged for 2. 8.3

TWO-INLET or TWO-OUTLET FUNCTION (3/2 & 3/3) BODY ASSEMBLIES 1/2 NPT 3/2 (three-port 2-position) BODY ASSEMBLY -7502- SA-7502-72-316 1/2 NPT (A/2 = INLET; IN/3 + EA/1 = OUTLET) -8502- SA-8502-72-316 1/2 NPT (IN/3 + EA/1 = INLET: A/2 = OUTLET) 3/3 (three-port 3-position) BODY ASSEMBLY Dimensions for 3/3 (Two-Inlet & Two-Outlet) Body Assemblies are the same as for 2-position Body Assemblies shown above. Body Assemblies with 3-position function: change fourth digit 2 in sub-assembly number into 3 for all ports blocked in center position. NOTE: Product number designations and subassembly numbers that are listed are for ExPilot type valves; for INPilot type valves the third digit 0 is exchanged for 2. 8.4

FOUR-WAY (5 port-2 position & 5 port-3 position) BODY ASSEMBLIES 1/4 NPT & 3/8 NPT.66 16.7.66 16.7.265 Ø 3HOLES A2 B4 N.J., USA & Netherlands EB 5 1.31 33.3 1.75 44.5.656 16.7 IN 3 3.50 88.9.656 16.7 1.31 33.3 EA 1 VERSA 1/4 NPT 5 PORTS.797 20.2 2.00 50.8.797 20.2 5/2 (fi ve-port 2-position) BODY ASSEMBLY -4302- SA-4302-61-316 1/4 NPT -4402- SA-4402-71-316 3/8 NPT 1.56 39.6 1.00.75 25.4 19.1 5/3 (fi ve-port 3-position) BODY ASSEMBLY -4303- SA-4303-61-316 1/4 NPT -4403- SA-4403-71-316 3/8 NPT Dimensions for 5/3 (Five-Port 3-position) Body Assemblies are the same as for 2-position Body Assemblies shown above. -4304- SA-4304-61-316 1/4 NPT -4404- SA-4404-71-316 3/8 NPT NOTE: Product number designations and subassembly numbers that are listed are for EXPilot type valves; for INPilot type valves the third digit 0 is exchanged for 2. 8.5

FOUR-WAY (5 port-2 position & 5 port-3 position) BODY ASSEMBLIES 1/2 NPT 5/2 (fi ve-port 2-position) BODY ASSEMBLY -4502- SA-4502-71-316 1/2 NPT 5/3 (fi ve-port 3-position) BODY ASSEMBLY -4503- SA-4503-71-316 1/2 NPT Dimensions for 5/3 (Five-Port 3-position) Body Assemblies are the same as for 2-position Body Assemblies shown above. -4504- SA-4504-71-316 1/2 NPT NOTE: Product number designations and subassembly numbers that are listed are for EXPilot type valves; for INPilot type valves the third digit 0 is exchanged for 2. 8.6

316 STAINLESS STEEL ACCESSORIES Manual Shut Off Valves General Description For Emergency Shut Down Systems, a Manual Bleed Valve designated MSO2-3-316, and a Manual Block and Bleed Valve designated MS03-3-316. Both valves, constructed of 316 Stainless Steel, are used as panic valves to quickly depressurize the system to get immediate shut-down. Even from remote locations, they enable the user to shutdown various processes in case of an emergency. Manual Bleed Valve The valve MS02-3-316 is a 2-way valve that is closed during normal operation. By pulling the red panel knob out, the valve opens and the Emergency Shutdown system pressure is dumped to atmosphere. Although compact and light weight, an internal orifi ce of 3/8 assures quick shut-down of the system. Because the valve is designed to work as a bleed type device only, any backpressure to the exhaust port will cause the valve to shift and open the inlet gate as if the panel knob were pulled out. Manual Block and Bleed Valve The valve MSO3-3-316 is a 3-way valve that can be used in the Emergency Shutdown system loop. During normal operation the inlet port is open to the outlet port, and the exhaust port is closed. By pulling the panel knob out, the inlet port is blocked and the outlet port is opened to exhaust port, so that the downstream system pressure is dumped to the atmosphere. Like the manual bleed valve, any backpressure to the exhaust port of the valve will cause the valve to shift, dumping downstream pressure, as if the panel knob were pulled out. Materials (Conform to NACE Standard MR-01-75) - 316 Stainless Steel - FKM (Fluorocarbon) O ring seals - Plastic palm button Weights MS02-3-316 0.77 lbs. (.35 kg) MS03-3-316 1.00 lbs. (.45 kg) Pressures On inlet port On exhaust port Porting & Flow Valve ports 1/4 NPT MS02-3-316: Cv=2.0 (Kv=29) MS03-3-316: Cv=1.0 (Kv=14.5) :0 to 150 psi (10 bar) air :0 psi (0 bar) backpressure Installation The valves can be panel mounted. Panel hole is 1 (25.4 mm) ø TWO-WAY (2/2) THREE-WAY (3-2) Block & Bleed Charge & Bleed Product Number Knob Color Product Number Knob Color MS02-3-316 Red MS03-3-316 Black MS02-3-316-125B Black MS03-3-316-125R Red 9.1

316 STAINLESS STEEL ACCESSORIES Shuttle Valve Shuttle valves provide the simplest way of pressurizing and exhausting a pilot chamber through the actuation of any one of two or more three-way valves. If two remote stations are required, one shuttle valve (in place of a tee) is required between the two three-way valves. For each additional remote station another shuttle valve is required. The shuttle valve prevents pressure from the actuated valve from being exhausted through the unactuated valve. In logic terms a shuttle valve is an OR function. A typical schematic is shown below: DIMENSIONS IN INCHES (mm) Materials (Conform to NACE Standard MR-01-75) Body: 316 stainless steel Shuttle: 316 stainless steel Seals: FKM (Fluorocarbon) Screws: 316 stainless steel Weight: 0.33 lbs. (0.15 kg) Porting: 1/4 NPT Pressures and Flow Pneumatic: Hydraulic: 3 to 200 psi (0.2 to 14 bar) 3 to 500 psi (0.2 to 35 bar) Cv=0.5 (Kv = 7) Installation Preferably with the centerline of the two inlet ports horizontal. As shown in the drawing above. Product Number SV-3-316 Bleed Control Valves DIMENSIONS IN INCHES (mm) The VERSA Bleed Control Valve has a precision machined needle that provides an economical, effective fl ow control in pneumatic applications. They can be threaded into the exhaust port of any VERSA directional control valve to provide speed control. The fl ow area, through which the air passes to the atmosphere, can be fi nely adjusted by screwing the needle in or out. After the Bleed Control Valve has been adjusted to suit, it can be securely locked at its setting with the lock nut provided. Materials (Conform to NACE Standard MR-01-75) 316 stainless steel Product Number Pressures 0 to 200 psi (0 to 14 bar) air BC-3-316 BC-4-316 1/4 NPT 3/8 NPT BC-5-316 1/2 NPT BC-6-316 3/4 NPT valve exhaust port 10.1

316 STAINLESS STEEL ACCESSORIES Quick Exhaust Valves (See Bulletin ACC for Electric Quick Exhaust Valves) DIMENSIONS IN INCHES (mm) A Quick Exhaust Valve is a 3/2 (three-way) valve with extra large exhaust orifi ce, to be fi tted directly at a cylinder port connection. When pressure decreases at the inlet of the Quick Exhaust Valve, the outlet is automatically opened to the exhaust and the cylinder is quickly depressurized. Materials (Conform to NACE Standard MR-01-75) Body: 316 stainless steel Seals: FKM (Fluorocarbon) O ring seals and CR (Neoprene) coated Nylon fl apper. Other parts: 316 Stainless Steel Weights QE-3-316 0.81 lbs (0.37 Kg) QE-5-316 2.16 lbs (0.98 Kg) QE-6-316 2.44 lbs (1.11 Kg) Dust Excluders Dust Excluders may be threaded into the exhaust ports in order to keep out dirt or dust in the atmosphere or surrounding the valve, that might enter through an otherwise open port. Materials (Conform to NACE Standard MR-01-75) Body: 316 Stainless Stell Seal: CR Chloroprene (Neoprene) Pressures 0 to 200 psi (0 to 14 bar) Installation Dust Excluders are preferably mounted in a vertical position with the wide outlet opening down. Valve exhaust port QE-6-316 Consult Factory Pressures 5-150 psi (0.34 to 10 bar) Temperature: QE-3-316 & QE-5-316:-20 F to 200 F (-29 C to 93 C) QE-6-316: -30 F to 350 F (-34 C to 177 C) Porting Type Inlet/Outlet Exhaust QE-3-316 1/4 NPT 3/8 NPT QE-5-316 1/2 NPT 3/4 NPT QE-6-316 3/4 NPT 1 NPT Flow Type IN to CYL CYL to EX QE-3-316 Cv=3.0(Kv=43.5) Cv=3.3 (Kv=48) QE-5-316 Cv=3/8 (Kv=55) Cv=8.8 (Kv=128) QE-6-316 Cv=4.6 (Kv=66) Cv=13.6 (Kv=195) Product Number QE-3-316 QE-5-316 QE-6-316 1/4 NPT 1/2 NPT 3/4 NPT Product Number DE-3-316 DE-4-316 1/4 NPT 3/8 NPT DIMENSIONS IN INCHES (mm) DE-5-316 DE-6-316 1/2 NPT 3/4 NPT 10.2

316 STAINLESS STEEL ACCESSORIES Status Indicator Panel Hole Opening Required : 1 Ø (25.4) 1/8-27 NPT Pressure Supply Port 1.5 (38) 2.48 (63) General Description Some applications require visual indication, when a system is pressurized or when a system has lost pressure. The Versa Status Indicator provides such a display within a stainless steel shell that can be mounted as an integral part of a panel. Viewing the panel provides the operator with an instantaneous evaluation of the pressure condition in the system or systems being monitored. Functional Description Versa s Status Indicator provides visual indication of pressure in a system. The standard product displays a green field when a minimum of 8 psi (0.55 bar) to a maximum of 200 psi (14 bar) is present. Complete loss of pressure causes the indicator to display a red field, marked with the recognition character R. Other field colors are available. See TYPES below. Materials: Body and internal wetted metal parts 316 Stainless Steel+ Working seals FKM (Fluorocarbon) Lens-polycarbonate (seal to prevent moisture intrusion), resistant to ultraviolet rays Porting: 1/8 NPT pressure supply port Pressures Operating pressure range: 0 to 200 psi (14 bar) air* Mounting Panel hole opening 1 (25.4mm) ø Can be mounted in any orientation with maximum panel thickness 0.50 (12.7mm) with one panel nut; maximum panel thickness 0.21 (5.3mm) with two panel nuts. (suffix -43E). Type/Weights Product Number SI-2-316 SI-2-316-403GR SI-2-316-403YG SI-2-316-403GY Depressurized 0 psi (0 bar) Red (R) Green (G) Yellow (Y) Green (G) Operating Pressure Range Pressurized 8 psi (0.55 bar) to 200 psi (14 bar) Weights Green Red Green Yellow } 0.50 lbs. (0.23 kg) *For hydraulic service consult factory. Conforms to NACE standard MR-01-75 10.3

IF YOU HAVEN T FOUND THE VALVE YOU NEED, YOU HAVEN T ASKED US. Versa Valves designed, built, and tested to meet your air requirements. SERIES B VALVES: 1/8 NPT, 3/16 (4.7mm) Orifi ce. Two- & Three-Way. Brass & SS Construction. Manual, Pilot & Cam Actuation. Pneumatic Service Vacuum to 200 psi (14 bar). Bulletin B. SERIES B-316, B-900 & B-550 AUTOMATION AND CONTROL VALVES & COMPONENTS FOR PROCESS CONTROL: Suitable for Offshore, Process Control, Material Specs Meet NACE MR-01-75. Fluorocarbon Seals, 1/4 NPT, 3/16 (5mm) Orifice. Three- Way. Solenoid/Pilot, Remote Pilot, Mechanical, Manual & Many Special Actuators. Main Supply Reset Valves; First Out Indicating Valves. Pneumatic Service Vacuum to 200 psi (14 bar). Bulletin B316 SERIES C VALVES: 10-32 (M5), 1/8 NPT OR G1/8, 1/4 NPT OR G1/4, 0.6 to 7mm Orifice. Three- & Four-Way, Multi-purpose. Individual Mount, Stacking, or Manifold Mounted. Aluminum, SS & Nylon Construction. Solenoid/ Pilot, Pilot, Manual & Mechanical Actuation. Pneumatic Service Vacuum to 115 psi (8 bar). Bulletin C. SERIES E VALVES: 1/8 NPT & 1/4 NPT. 1/32 (0.8mm) thru 1/4 (6.4mm) Orifice. Two- & Three-Way, Directional, Multi-Purpose. Sideported, and Manifold Mounted. SS or Aluminum Construction. Direct Solenoid Actuation, including LOW WATT. Pneumatic & Hydraulic Service Vacuum to 500psi (35 bar). Bulletin E. SERIES K VALVES: Compact Air Management System. ¼ NPT or G1/4, 4.7mm & 6.5mm Orifi ce. Two-, Three-, Four- & Five-Way, Selector, Diverter. Manifold Mounted, Integrated Circuitry, Aluminum Construction. Fluorocarbon Seals. Solenoid/Pilot, Remote Pilot, Cam & Manual Actuation. Pneumatic Service Vacuum to 175 psi (12 bar). Bulletin K. SERIES H VALVES: High pressure hydraulic valves: High pressure valves for the Oil & Gas Industry; to 10,000 psi operating pressure, 316 stainless steel construction, leakproof, balanced dynamic ceramic sealing, O ring static seals, modular design, manifold mounting. Bulletin H SERIES V & T VALVES: 1/8 thru 1-1/4 NPT or G, Full Ported, Two-, Three-, Four- & Five- Way, Selector, Diverter. All types of Actuation. Forged Brass Construction. Pneumatic Service Vacuum to 200 psi (14 bar), Hydraulic Service to 500 psi (35 bar). Bulletin VT. SERIES V-316 STAINLESS STEEL VALVES: Suitable for Offshore, Process Control, Material Spec Meet NACE MR-01-75. Fluorocarbon Seals. 1/4, 3/8, 1/2 NPT, Full Ported. Two-, Three-, Four- & Five-Way. Selector. Diverter. All Type of Actuation. Pneumatic Service Vacuum to 200 psi (14 bar). Bulletin V316. SOLENOID VALVES FOR THE PROCESS CONTROL INDUSTRY: Complete Range of Stainless Steel, Brass or Aluminum Constructed Valves, 1/8 NPT through 1 NPT. Direct NAMUR Mount & Bodyported Styles. Latching Manual Reset, Lockout Valves, Redundant Valves. Bulletin PCg. ACCESSORIES: Shuttle Valves, Bleed Control Valves, Dust Excluders, Foot Guards, Bleed Valves, Quick Exhaust Valves, Status Indicators. Bulletin ACC. The warnings below must be read and reviewed before designing a system utilizing, installing, servicing, or removing a Versa product. Improper use, installation or servicing of a Versa product could create a hazard to personnel and property. DESIGN APPLICATION WARNINGS Versa products are intended for use where compressed air or industrial hydraulic fluids are present. For use with media other than specified or for non-industrial applications or other applications not within published specifications, consult Versa. Versa products are not inherently dangerous. They are only a component of a larger system. The system in which a Versa product is used must include adequate safeguards to prevent injury or damage in the event of system or product failure, whether this failure be of switches, regulators, cylinders, valves or any other system component. System designers must provide adequate warnings for each system in which a Versa product is utilized. These warnings, including those set forth herein, should be provided by the designer to those who will come in contact with the system. Where questions exist regarding the applicability of a Versa product to a given use, inquiries should be addressed directly to the manufacturer. Confirmation should be obtained directly from the manufacturer regarding any questioned application prior to proceeding. INSTALLATION, OPERATION AND SERVICE WARNINGS Do not install or service any Versa product on a system or machine without first depressurizing the system and turning off any air, fluid, or electricity to the system or machine. All applicable WARNINGS REGARDING THE DESIGN APPLICATION, INSTALLATION AND SERVICE OF VERSA PRODUCTS electrical, mechanical, and safety codes, as well as applicable governmental regulations and laws must be complied with when installing or servicing a Versa product. Versa products should only be installed or serviced by qualified, knowledgeable personnel who understand how these specific products are to be installed and operated. The individual must be familiar with the particular specifications, including specifications for temperature, pressure, lubrication, environment and filtration for the Versa product which is being installed or serviced. Specifications may be obtained upon request directly from Versa. If damages should occur to a Versa product, do not operate the system containing the Versa product. Consult Versa for technical information. LIMITED WARRANTY DISCLAIMER AND LIMITATION OF REMEDIES Products sold by Versa are warranted to be free from defective material and workmanship for a period of ten years from the date of manufacture, provided said items are used in accordance with Versa specifications. Versa s liability pursuant to that warranty is limited to the replacement of the Versa product proved to be defective provided the allegedly defective product is returned to Versa or its authorized distributor. Versa provides no other warranties, expressed or implied, except as stated above. There are no implied warranties of merchantability or fitness for a particular purpose. Versa s liability for breach of warranty as herein stated is the only and exclusive remedy and in no event shall Versa be responsible or liable for incidental or consequential damages. Versa Products Company, Inc., 22 Spring Valley Road, Paramus, New Jersey, USA 07652 201/843-2400 FAX: 201/843-2931 Versa BV., Prins Willem Alexanderlaan 1429, 7312 GB Apeldoorn, The Netherlands 01131-55-3681900 FAX: 01131-55-3681909 www.versa-valves.com