High Voltage Copper, Smooth Aluminum Shield/Sheath

Similar documents
High Voltage Aluminum, Smooth Aluminum Shield/Sheath

LCT Shielded Primary UD EPR LCT Shielded Primary UD EPR Cable

LCT Shielded Primary UD TRXLP LCT Shielded Primary UD TRXLP Cable

MC or MV-105 Copper, TR-XLPE Insulated

UNDERGROUND TRANSMISSION SOLUTIONS PRODUCT CATALOG

UNDERGROUND TRANSMISSION SOLUTIONS

OFFSHORE WIND FEASIBILITY STUDY APPENDICES Appendix C.2 Subsea Cable Data Sheets

TC-XHHW-2 Copper, XLPE Insulated, PVC Jacketed

TC-RHH/RHW-2 USE-2 Copper

C-L-X Aluminum Sheath Type IEC

Corflex. Continuous Corrugated Aluminum Sheathed PL, MC and MV Industrial Cables. Introduction Applications... 3

TC-XHHW-2 Copper, XLPE Insulated, PVC Jacketed

TECHNICAL GUIDELINE. Medium Voltage Conductor Ampacities ALUMINUM COPPER. Single Conductor 5kV - 35kV

Okoguard -Okoseal Type IEC

Caledonian Medium Voltage Cables

Caledonian Medium Voltage Cables

Caledonian Medium Voltage Cables Three Core Cables to VDE 0276-

MEDIUM VOLTAGE

TC-THHN/THWN-2 Copper, PVC/Nylon Insulated

Medium Voltage Cable. marmonutility.com

TC-THHN/THWN-2 Copper, PVC/Nylon Insulated

Introduction. Nexans wire and cable. Contact us for all your wire and cable needs

Medium Voltage Power Cables

Medium Voltage Cables for PermaLife Nuclear Utility Applications

Solid PE Insulated & LAP Sheathed Air Core/Jelly Filled Cables to DIN VDE 0816

sa B-CABLES nv PROTOLON(ST) NTSCGEWOEU.../3E Medium Voltage Flexible Cables for Use in Water with Copper Core Shield sa B-CABLES nv ENERGY

NA2XSEKRY 3 x (25-300) mm² 3.6/6 kv

High Voltage and Extra High Voltage Cables

Power & Control Cable IEC

MC, THHN/THWN-2 Copper

NA2XSEKY 3 x (25-300) mm² 3.6/6 kv

PROTOLON (SB) PROTOLON (SB) with Copper Core Shield Flexible Cables for Trailing Operation

4. SHIELDS. 4.1 Power Cable. 4.2 Electronic Cable Conductor Shield (Strand Shield) Outer Shield (Insulation Shield) 60

North America HIGH&EXTRA-HIGH VOLTAGE UNDERGROUND SOLUTIONS

Type MMV-WP Medium Voltage Wind Power Cable

Company Profile. Caledonian Medium Voltage Cables


CORFLEX. Continuous Corrugated and Welded, Impervious Aluminum Sheathed PL, MC and VFD Industrial Cables. Introduction Applications...

XLPE Cable Systems. User s guide. rev. 2

XLPE CABLES AND CABLE SYSTEMS KV MODERN SOLUTIONS FOR POWER CABLES/ESTRALIN HVC

sa B-CABLES nv PROTOLON(ST) NTSCGEWOEU Medium Voltage Flexible Cables for Use In Water sa B-CABLES nv ENERGY

ALUMINUM UNDERGROUND ALHIDE 600 VOLT SINGLE LAYER RUGGEDIZED CABLES. grounded in service wired to innovate TM. Black Crosslinked.

200 A 25 kv and 28 kv class loadbreak elbow connector with optional integral jacket seal-canadian Edition

200 A 15 kv class loadbreak elbow connector with optional integral jacket seal

Loadbreak Apparatus Connectors

Quintas & Quintas Group

SPECIFICATION FOR EXTRUDED DIELECTRIC, SHIELDED POWER CABLES RATED 5 THROUGH 46 kv

Easy-On II Terminations

Power & Control Cable IEC

Tests are conducted in accordance with IEEE Standard 386. ac 60 Hz 1 Minute Withstand 50

600/1000V XLPE Insulated PVC Sheathed Power Cables (Multicore)

grounded in service wired to innovate STABILOY Type XHHW-2 and USE-2/RHH/RHW-2

NEC 2014 Code Changes

List of Malaysian Standard (MS) for Cables. Prepared by MCMA SWO. Cable - Armoured. Cable - Armoured

Deadbreak Apparatus. connectors. 600 A 15/25 kv Class GENERAL

Airfield Ground Lighting

INSTALLATION PRODUCTION TESTS

Gexol. Gexol. World Class Oil & Gas Cables. The Global Cable Solutions Company

NYY-J Cable. Dungannon Electrical Wholesale Tel: Page 1 of 10

N2XSEBY 3 x (25-300) mm² 3.6/6 kv

NA2XSEY 3 x (25-300) mm 2 3.6/6 kv

Submarine Power Cables

ANSI/NEMA WC ICEA No. S Portable and Power Feeder Cables for Use in Mines and Similar Applications

Your Partner in Safe Power Solutions. About RESCAB

Control Cable Type P 600/1000 volts DRILMAR 125-XE Crosslinked Polyolefin Insulated Drilling Rig and Marine Cable

Power & Control Cables. U o. /U 0.6/1 kv - IEC

3M Cold Shrink 3-Conductor Inline Splice Kits QS-III 5786A- MT, 5787A-MT and 5788A-MT 25/28 kv for use with Armored and Non- Armored 3/C Cable

11. CABLE SPECIFICATIONS 5kV, 15kV, AND 35kV RUBBER OR PLASTIC INSULATED CABLE

Power & Control Cables

DURAREEL TRAILING REELING CABLE

Quick Splice II 5451R. 25/28 kv Molded Rubber Cable Repair Splicing Kit Data Sheet. 1. Product Description. 2. Applications

11. CABLE SPECIFICATIONS 5kV, 15kV, AND 35kV RUBBER OR PLASTIC INSULATED CABLE

PRODUCTS COMMERCIAL BUILDING WIRE & CABLE

200 A 15 kv class loadbreak elbow connector with optional integral jacket seal-canadian Edition

N2XSEFGbY 3 x (25-300) mm² 3.6/6 kv

Quick Splice II. 35 kv Molded Rubber Inline Splicing Kit Data Sheet. 2. Applications. 1. Product Description

DLO. Mining Cable. Mining Cable. 2 kv

RG7H1R-1,8/3 26/45 kv RG7H1OR-1,8/3 18/30 kv

Loadbreak Apparatus Connectors. 200 A 15 kv Class Loadbreak Elbow Connector with Optional Integral Jacket Seal GENERAL

3 Cold Shrink Silicone Rubber Skirted Termination Kit QT-III 7672-S-8 Series

Section 11 Mining Cable

copper stud. If a 900 A rating is desired, specify a C as the 8th digit when determining your part number (See Table 3, page 3.)

FR-3S Fire Resistant Cables

FTG10OM1-0,6/1KV. 50 N/mm 2 of copper section max for fixed layings

Type P Drilmar 125-XE Signal & Instrumentation

200 A 25 and 28 kv class POSI-BREAK loadbreak elbow connector with optional integral jacket seal-canadian Edition

MEDIUM VOLTAGE POWER CABLES

INDUSTRIAL

Introduction. Phone (888) Fax (800) Int l Phone Int l Fax

600 A 35 kv class separable splices

Type P Drilmar 125-XE Signal & Instrumentation

TUNNELING POWER CABLES

High Voltage Joints and Terminations up to 72,5 kv 145 kv

PROTOLON(FL)-LWL (N)TSFLCGEWOEU 3,6/6 kv: medium voltage flat reeling cable with fibre-optics

Control Cable Type T/N 600/1000 volts DRILMAR 90 Polyvinyl Chloride/Nylon Insulated Drilling Rig and Marine Cable

CORDAFLEX(SMK) (N)SHTÖU Tough Rubber-Sheathed Reeling Cables

3M Cold Shrink QS-III Inline Splice Kits 15 kv 5513A, 5514A, 5515A and 5516A

N2XY IEC XLPE PVC 0.6/1kV Cable

QTII (X) Series Silicone Rubber Cold Shrink Termination Kits

QS-III. 5513A, 5514A, 5515A and 5516A 15 kv Cold Shrink Inline Splice Kits. Data Sheet CAUTION. 1. Product Description. 2. Applications.

Transcription:

High Voltage Copper, Smooth Aluminum Shield/Sheath XLPE Insulation, HDPE Jacket, 69 kv - 138 kv Features True triple vertical extrusion system for optimum insulation concentricity, and excellent electric field control. Dry cure process. Closed handling of raw materials system to eliminate any contact with ambient, until extrusion process ends. Low dielectric losses. Metallic shield for ground connection. Sunlight resistant jacket. Application Transmission and distribution circuits, in cities with high load densities. Also, for Industrial and Commercial installations. May be installed in wet or dry locations indoors or outdoors in conduit and underground ducts. Standards IEC 60840: Power cables with extruded insulation for rated voltages above 30 kv up to 150 kv. AEIC CS9: Specifications for extruded insulation power cables and their accessories rated above 46 kv through 345 kv. ICEA S-108-720: Standard for extruded insulation power cables rated above 46 kv to 345 kv. Specifications Operating (maximum) voltage: 69 kv (72.5 kv), 115 kv (123 kv) or 138 kv (145 KV) Maximum conductor operation temperatures: Wet and dry locations Normal: 90 C Emergency: 105 C Short Circuit: 250 C Engineering Information 1. Conductor: Uncoated soft annealed copper, Class B or Class 2 filled stranding compacted round or segmental as per ASTM B496 or IEC 60228. Sizes: 500 kcmil up to 4000 kcmil. On request, unfilled conductor. 2. Semiconducting Tape: A semiconducting tape may be applied helically with an overlap, as required. 1 2 3 4 5 3. Conductor Shield: Semiconducting crosslinked polyethylene. 4. Insulation: High quality, heat, moisture, ozone and corona resistant, crosslinked polyethylene (XLPE). 5. Insulation Shield: Semiconducting crosslinked polyethylene. 6. Water Barrier: Semiconducting water blocking tape, helically applied. 7. Metallic Shield/Sheath: Welded smooth aluminum tape longitudinally applied over semiconducting water blocking tapes. 8. Jacket: Black high density polyethylene (HDPE) sunlight resistant thermoplastic compound. 6 7 8 On request, semiconducting PE layer. High Voltage - Primary UD Cable

69 kv Copper, XLPE Insulated Size kcmil 500 750 1000 1250 1500 1750 2000 2500 3000 3500 4000 Conductor Shape Round Segmental Number of Strands 37 61 61 61 61 85 85 305 305 305 305 Conductor Diameter in 0.74 0.91 1.06 1.21 1.31 1.48 1.57 1.78 1.95 2.12 2.28 Insulation Insulation Thickness mil 380 360 340 330 320 320 310 310 300 300 300 Insulation OD in 1.57 1.71 1.82 2.02 2.09 2.27 2.34 2.55 2.70 2.87 3.03 Metallic Sheath Thickness mil 60 Diameter over sheath in 1.96 2.09 2.2 2.4 2.48 2.65 2.72 2.94 3.09 3.26 3.42 Complete Cable Outside Diameter Net Weight Minimum Bending Radius Maximum Pulling Tension in 2.36 2.50 2.61 2.81 2.88 3.06 3.13 3.35 3.50 3.67 3.83 lb/ft 3.4 4.3 5.2 6.3 7.1 8.1 8.9 10.9 12.6 14.5 16.1 in 49 51 54 58 59 63 64 68 71 75 78 lb 4,000 6,000 8,000 10,000 12,000 14,000 16,000 20,000 24,000 28,000 32,000 Electrical Stress @ U 0 Conductor Shield kv/mm 5.8 5.8 5.8 5.8 5.9 5.8 5.9 5.8 5.9 5.8 5.8 Insulation Shield kv/mm 3.0 3.3 3.6 3.9 4.1 4.1 4.3 4.4 4.6 4.6 4.6 Short Circuit for 0.5 s Conductor ka 50.9 76.3 101.8 127.2 152.6 178.1 203.5 254.4 305.3 356.1 401.6 Sheath ka 28.3 30.3 32.0 34.9 36.0 38.6 39.7 43.0 45.2 47.7 50.2 Conductor Resistance dc @ 20 C Ω/kft 0.021 0.014 0.011 0.009 0.007 0.006 0.005 0.004 0.004 0.003 0.003 dc @ 90 C Ω/kft 0.027 0.018 0.013 0.011 0.009 0.008 0.007 0.005 0.005 0.004 0.003 Capacitance pf/ft 53.1 63.8 74.7 88.3 95.7 105.4 113.4 125.5 139.1 149 158.5 Charging Current A/kft 0.80 0.96 1.12 1.33 1.44 1.58 1.70 1.88 2.09 2.24 2.38 Ampacity @ 90 C (3 ft top of duct, 1 C m/w native, 20 C Ambient, 75% if single-point or cross bonded) Single Circuit Bank A 669 831 971 1090 1187 1274 1349 1588 1737 1867 1982 Double Circuit Bank A 561 691 799 896 971 1036 1090 1333 1453 1559 1651 The above data are approximate and subject to normal manufacturing tolerances.

115 kv Copper, XLPE Insulated Size kcmil 750 1000 1250 1500 1750 2000 2500 3000 3500 4000 Conductor Shape Round Segmental Number of Strands 61 61 61 61 85 85 305 305 305 305 Conductor Diameter in 0.91 1.06 1.21 1.31 1.48 1.57 1.78 1.95 2.12 2.28 Insulation Insulation Thickness mil 730 680 630 610 590 580 570 550 540 540 Insulation OD in 2.46 2.51 2.63 2.68 2.82 2.89 3.08 3.21 3.36 3.52 Metallic Sheath Thickness mil 60 Diameter over sheath in 2.84 2.90 3.02 3.07 3.20 3.27 3.48 3.61 3.76 3.92 Complete Cable Outside Diameter Net Weight Minimum Bending Radius Maximum Pulling Tension Electrical Stress @ U 0 in 3.25 3.30 3.42 3.47 3.61 3.68 3.88 4.01 4.16 4.32 lb/ft 5.7 6.6 7.5 8.3 9.3 10.2 12.2 13.9 15.7 17.4 in 67 68 70 71 74 75 79 82 85 88 lb 6,000 8,000 10,000 12,000 14,000 16,000 20,000 24,000 28,000 32,000 Conductor Shield kv/mm 5.8 5.8 5.9 5.9 5.9 5.9 5.8 5.9 5.9 5.8 Insulation Shield kv/mm 2.3 2.6 3.0 3.2 3.4 3.5 3.6 3.8 4.0 4.0 Short Circuit for 0.5 s Conductor ka 76.3 101.8 127.2 152.6 178.1 203.5 254.4 305.3 356.1 401.6 Sheath ka 41.5 42.3 44.0 44.8 46.9 47.9 50.9 52.9 55.1 57.5 Conductor Resistance dc @ 20 C Ω/kft 0.014 0.011 0.009 0.007 0.006 0.005 0.004 0.004 0.003 0.003 dc @ 90 C Ω/kft 0.018 0.013 0.011 0.009 0.008 0.007 0.005 0.005 0.004 0.003 Capacitance pf/ft 38.5 44.5 53.2 57.2 64.0 67.6 75.1 82.8 89.5 94.8 Charging Current A/kft 0.96 1.11 1.33 1.43 1.60 1.69 1.88 2.07 2.24 2.37 Ampacity @ 90 C (3 ft top of duct, 1 C m/w native, 20 C Ambient, 75% if single-point or cross bonded) Single Circuit Bank A 821 955 1069 1166 1250 1323 1599 1751 1886 2001 Double Circuit Bank A 694 803 894 970 1037 1096 1318 1437 1541 1632 The above data are approximate and subject to normal manufacturing tolerances.

138 kv Copper, XLPE Insulated Size kcmil 750 1000 1250 1500 1750 2000 2500 3000 3500 4000 Conductor Shape Round Segmental Number of Strands 61 61 61 61 85 85 305 305 305 305 Conductor Diameter in 0.91 1.06 1.21 1.31 1.48 1.57 1.78 1.95 2.12 2.28 Insulation Insulation Thickness mil 970 890 810 790 760 740 710 700 680 670 Insulation OD in 2.94 2.93 2.99 3.04 3.16 3.21 3.36 3.51 3.64 3.78 Metallic Sheath Thickness mil 60 Diameter over sheath in 3.32 3.32 3.38 3.43 3.54 3.59 3.76 3.91 4.04 4.18 Complete Cable Outside Diameter Net Weight Minimum Bending Radius Maximum Pulling Tension Electrical Stress @ U 0 in 3.73 3.72 3.78 3.83 3.95 4.00 4.16 4.31 4.44 4.58 lb/ft 6.9 7.5 8.4 9.2 10.1 11.0 12.9 14.7 16.5 18.1 in 76 76 77 78 81 82 85 88 90 93 lb 6,000 8,000 10,000 12,000 14,000 16,000 20,000 24,000 28,000 32,000 Conductor Shield kv/mm 5.9 5.9 5.9 5.9 5.8 5.9 5.9 5.8 5.9 5.9 Insulation Shield kv/mm 1.9 2.3 2.7 2.8 3.0 3.1 3.4 3.5 3.7 3.8 Short Circuit for 0.5 s Conductor ka 76.3 101.8 127.2 152.6 178.1 203.5 254.4 305.3 356.1 401.6 Sheath ka 48.7 48.5 49.4 50.2 51.9 52.7 55.1 57.3 59.3 61.4 Conductor Resistance dc @ 20 C Ω/kft 0.014 0.011 0.009 0.007 0.006 0.005 0.004 0.004 0.003 0.003 dc @ 90 C Ω/kft 0.018 0.013 0.011 0.009 0.008 0.007 0.005 0.005 0.004 0.003 Capacitance pf/ft 32.3 37.3 44.7 47.6 53.1 56.3 63.5 68.5 74.5 79.7 Charging Current A/kft 0.97 1.12 1.34 1.43 1.59 1.69 1.91 2.06 2.24 2.39 Ampacity @ 90 C (3 ft top of duct, 1 C m/w native, 20 C Ambient, 75% if single-point or cross bonded) Single Circuit Bank A 820 950 1058 1155 1241 1317 1589 1738 1871 1986 Double Circuit Bank A 691 799 885 961 1036 1090 1310 1428 1532 1621 The above data are approximate and subject to normal manufacturing tolerances.

Notes In this publication, conductor sizes are given in kcmil. According to the best practice in industry, when using pulling eyes attached to phase conductors, the maximum mechanical pulling tension that can be applied to each conductor or group of conductors being installed in ducts, should not be higher than 6,000 lbf. Doing calculations of cable pulling tensions prior to each installation, increases the possibilities of a safe and secure operation. Installation conditions taken as reference for ampacity calculations are: 1. One and two three phase circuits, cables in underground buried ducts, one cable per duct, flat parallel configuration with a distance between duct centers of twice the OD of each cable. 2. 75% Load Factor. 3. Single point or cross bonded shield grounding connection. 4. Ambient Ground Temperature, Ta = 20 C. 5. Deep to top of ducts, 3 ft. 6. Ground Thermal Resistivity: 1 C m/w. For this publication, ampacity values were calculated according to the available best engineering practice (per IEC 60287). However, they should be considered as reference values only, applicable to the conditions described below. For other cases, correction factors can be applied as follows: Deep, m 1.0 1.2 1.3 1.5 2.0 2.5 3.0 3.5 4.0 4.5 5.0 Factor 1.03 1.01 1.00 0.98 0.95 0.93 0.91 0.89 0.88 0.87 0.86 Soil Thermal Resistivity ( C ) 0.8 1.0 1.2 1.5 2.0 2.5 Factor 1.09 1.00 0.93 0.85 0.75 0.67 Soil Temperature ( C ) 10 15 20 25 30 35 40 Factor 1.07 1.04 1.00 0.96 0.92 0.88 0.84 Temperature Correction Factor Distance Between Centers mm 400 600 800 1000 1 circuit 1.00 1.00 1.00 1.00 2 circuit 0.79 0.83 0.87 0.89 3 circuit 0.70 0.75 0.78 0.81 4 circuit 0.64 0.70 0.74 0.78 Only nominal dimensions are included in this publication. For accessary selection, please contact our Sales Department.

This page intentionally left blank