Instruction/Installation Manual

Similar documents
TECTONIC LED CORP. ISO

LED 2/3/4ft T8 Tube 120V

Product Installation Instruction LED Tube Lamp Retrofit Kits

Installation Guide. WARNINGS Read all instructions and warnings before attempting installation


Installation Instructions: Memory-Dimmable SEP T8 Tube Lamps

Solid State T8 tube is the smart alternative to a

Strip Fixture URS Light Bar Retrofit Installation Instructions Revised:

ULTRA PERFORMANCE LED TUBE INSTALLATION INSTRUCTIONS

Universal Retrofit System Installation Instructions Revised:

STOP BEFORE YOU BEGIN READ THESE INSTRUCTIONS COMPLETELY AND CAREFULLY

Installation Instructions: External-Driver SEP T8 LED Tube Lamp

INSTALLATION INSTRUCTIONS 120V DirectAC LED Engine Kit

INSTALLATION INSTRUCTIONS

LUNERA T8 LED RETROFIT KITS 1/2/3/4-Lamp Replacement Kits for 2FT or 4FT T8 Fluorescent Lamps

Installation Instructions: Eco-Fit T8 LED Tube Lamp

T8 Tube Light. UL LISTED & cul LISTED & DLC LISTED. Germany Patent: Gebrauchsmusters / Nr

LUNERA T8 LED RETROFIT KITS 2/3/4-Lamp Replacement Kits for 2FT or 4FT T8 Fluorescent Lamps

Stik Families GENERAL PURPOSE RETROFIT SIGN CONVERSION FOR USE ONLY IN ACCORDANCE WITH KIT INSTRUCTIONS

INSTALLATION INSTRUCTIONS ModuSys LED Retrofit Kit 2x2, rev. D.02

LED Recessed Troffer Retrofit Kit

LED IMPORTANT SAFETY INSTRUCTIONS

Installation Instructions BLTR and 2BLTR Relight Assembly

READ AND FOLLOW ALL SAFETY INSTRUCTIONS! SAVE THESE INSTRUCTIONS AND DELIVER TO OWNER AFTER INSTALLATION.

MAXLITE RKT LED Retrofit Kit

LED. High-performance streetlight. -afortable and reliable

Assembly Instructions Retrofitting

READ AND FOLLOW ALL SAFETY INSTRUCTIONS 1. DANGER RISK OF SHOCK DISCONNECT POWER BEFORE INSTALLATION

SURE-LITES FBP140XLP Instruction Manual

READ AND FOLLOW ALL SAFETY INSTRUCTIONS! SAVE THESE INSTRUCTIONS AND DELIVER TO OWNER AFTER INSTALLATION.

INSTALLATION INSTRUCTIONS

OPTIMAX RADIANT FIELD RETROFIT INSTRUCTIONS

LED T8 Full Glass Tube

Optimax Pro Retrofit Instructions

INSTRUCTION MANUAL IMPORTANT SAFEGUARDS. When using electrical equipment, basic safety precautions should always be followed, including the following:

3. Please ensure the electricity connections conform to the National Electrical Code and local regulations if applicable.

S HINE V ENTURE L IGHTING S LED LAMPS. Quality retrofit LED lighting products from a leader in the lighting industry. Full range dimming

General Installation Instructions LED

INSTRUCTION MANUAL. IMPORTANT SAFEGUARDS When using electrical equipment, basic safety precautions should always be followed, including the following:

INSTRUCTION MANUAL. IMPORTANT SAFEGUARDS When using electrical equipment, basic safety precautions should always be followed, including the following:

SubstiTUBE Value EM T8 (AUS Fighter Tube) ST8V-0.6M ST8V-1.2M ST8V-1.5M

INSTALLATION INSTRUCTIONS STEP-DOWN TRANSFORMER HOUSING KIT

ILLUMINA BS100 INSTALLATION INSTRUCTIONS FLUORESCENT VAPOR TIGHT

KT-EMRG-1400-SL /B. 3. Please ensure the electricity connections conform to the National Electrical Code and local regulations if applicable.

Lumination TM LED Luminaire LUR Series

LED Utility Wrap Fixture

INSTRUCTION MANUAL IMPORTANT SAFEGUARDS. When using electrical equipment, basic safety precautions should always be followed, including the following:

LUNERA VERTICAL E26 LED FLOODLIGHT LED Replacement for E26 Medium Base Floodlights Type B Ballast Bypassed

Quick Installation Guide. Affinium LED Modules LFM300 for Refrigerated Display Cases

IMPORTANT SAFEGUARDS When using electrical equipment, basic safety precautions should always be followed including the following:

Asymmetrical Installation Instructions. Components: i2cove Asymmetrical LED Light Fixtures. 12 [305mm] [918mm] 48.

LM79 LM80 L70:5+ YEARS

INSTALLATION GUIDE Works in double and single ended wiring.

PDX and PX Retrofit Series

Light Source User Guide

INSTALLATION INSTRUCTIONS For Light*Waves Flex II Kit with 300-Watt remote transformer

LED T8 BP. GE Lighting. Tubular lamps DATA SHEET. Specification Features. Product information. Applications. IEC standards

LEDlescent TM T8 Ballast-Free Lamps

LED Flat Panel Installation Instructions For 1 x4, 2 x2, and 2 x4 LED Flat Panels (FP Series)

Battery Chargers Sealed or Valve Regulated Lead Acid Batteries Model: PSC AP

INSTALLATION INSTRUCTIONS LED RETROFIT ASSEMBLY (LRA) Rev F

Motion and Light Sensor Kit LHBAS51

Installation Instructions: Eco Linear High Bay

28W WORK LAMP Model: CTL28 Part No:

Installation Instruction ALG Series LED Area Light Version: 3.1

BALT5-800 LOW-PROFILE FLUORESCENT EMERGENCY BALLAST

CFP-LED Contractor Select Flat Panel. Installation Instructions

INSTRUCTION MANUAL SINKER. By HAY

MaxLite LED UTILITY WRAP FIXTURES

CONSTRUCTION Aerodynamic aesthetical design optimized for LED characteristics. Modular design for easily installation and maintenance.

HPNLS-HO. Installation Manual

INSTALLATION INSTRUCTIONS LED Canopy Retrofit Kit

Light Source User Guide

Battery Chargers Sealed or Valve Regulated Lead Acid Batteries Model: PSC A

23W Dimmable LED Bulb - 4' T8 Lamp Lumens - Double Ended- Replacement/Upgrade for Fluorescent

PIL0478 ISSUE 01/ 07/16

ECO EXT (DIMMABLE)

Linear Replacement Lamps

MONORAIL KITS INSTALLATION INSTRUCTIONS PENDANTS

ESLED4, ESLED5 Instructions

13IN. WAREHOUSE BARN RETROFIT LIGHT OWNER S MANUAL

UFO-RP2 FLUORESCENT BATTERY PACK IMPORTANT SAFEGUARDS READ AND FOLLOW ALL SAFETY INSTRUCTIONS

UL AND CODE COMPLIANCE

Linear Tubes Compacts

UFO-RP3 FLUORESCENT BATTERY PACK IMPORTANT SAFEGUARDS READ AND FOLLOW ALL SAFETY INSTRUCTIONS

LED Linear Lamp. 2, 3, 4, 5 lamps. Performance Specifications. LED T8 and T12 lamps

(L 70 ) 3000K / 4000K / 5000K 12 50,000 50, K / 4000K / 5000K 15 50, K / 4000K / 5000K 18 50,000

P/N Wheeler. user manual

MODELS. 2 & 4 Low Profile Linears

MaxLite StaxMax LED Flood Lights

MaxLite LED Linear HighBay Fixtures

FLUORESCENT EMERGENCY BALLAST Lumens. When using this lighting device safety precautions should be followed at all times

FiberSource Q150. user manual P/N

LED IMPORTANT SAFETY INSTRUCTIONS

Specification sheet of T8 LED Tube

LED Fluorescent Replacement

TRUET5 EXT (DIMMABLE)

Measurements are expressed in millimeters.

MEDIA LED. Pendant Standard Mount Installation ou de montage WARNING:

ATM Lighting sp. z o.o

Transcription:

Instruction/Installation Manual Retrofit:LED Tube Lamp 4ft. Fluorescent T8/T10 Replacement 1

SECTION 1 - General Information Kit components:1-led Tube, 1-Label and 1-Set of Instructions Models were only evaluated for factory installation to end luminaire, or to end Retrofit Luminaire, intended to replace a fluorescent lamp where it is necessary to modify the luminaire. These LED Tube Lamps are intended to retrofit a maximum of four lamps, mount fluorescent luminaries that use straight tubular 4-foot lamps. - These lamps should be installed by a licensed electrician. - These lamps operate at line voltage and require all ballasts to be removed before the bulb is to be installed in the luminaire. - These lamps are to be used in dry or damp locations only. Do not use in wet locations. - These lamps are not to be used with a light dimmer. Any ballasts need to be bypassed. - Always connect ground lead to luminaire where applicable. - Please contact superbrightleds.com if you have any questions not addressed in these instructions. Please see contact information on the last page. SECTION 2 - WARNING WARNING RISK OF ELECTRICAL SHOCK DO NOT OPEN WARNING: To reduce the risk of electrical shock, do not remove cover and caps No user-serviceable parts inside. Refer servicing to qualified service personnel. WARNING : TO REDUCE THE RISK OF FIRE OR ELECTRICAL SHOCK, DO NOT EXPOSE THIS APPARATUS TO RAIN OR MOISTURE LUMINAIRE CONVERSION, RETROFIT FOR USE ONLY WITH FLUORESCENT LUMINAIRES IDENTIFIED IN MANUFACTURER' S INSTRUCTIONS THIS PRODUCT MUST BE INSTALLED IN ACCORDANCE WITH THE APPLICABLE INSTALLATION CODE BY A PERSON FAMILIAR WITH THE CONSTRUCTION AND OPERATION OF THE PRODUCT AND THE HAZARDS INVOLVED. These lamps can be used in any standard T8 lamp luminaire, allowing for its minimum spacing requirements 30mm 50mm Minimum distance between lamps Minimum distance between lamps pin sockets 2

WARNING - Risk of fire or electric shock. Retrofit kit installation requires knowledge of fluorescent lighting luminaires electrical systems. If not qualified, do not attempt installation, contact a qualified electrician. WARNING - Risk of fire or electric shock. The electrical rating of this product is AC100V~277V, the installer must determine whether they have AC100V~277V at the luminaire before installation. WARNING - Risk of fire or electric shock. Only install this kit in fixtures it was designed for as shown by the dimensions and images. WARNING - To prevent wiring damage or abrasion, do not expose wiring to edges of sheet metal or other sharp objects. WARNING - THE RETROFIT ASSEMBLY IS ACCEPTED AS A COMPONENT OF A FLUORESCENT LUMINAIRE WHERE THE SUITABILITY OF THE COMBINATION SHALL BE DETERMINED BY UL OR AUTHORITIES HAVING JURISDICTION. Note: Shunted lamp holders are found only in fluorescent luminaires with Instant-Start ballasts. Instant-start ballasts can be identified by the words "lnstant Start" or "l.s." marked on the ballast. This designation may be in the form of a statement pertaining to the ballast itself, or may be combined with the marking for the lamps with which the ballast is intended to be used, for example F40T12/IS. 3

Do not make or alter any open holes in an enclosure of wiring or electrical components during kit installation. Not for use with dimmers. Once installation is completed the luminaire has been modified and can no longer operate the originally intended lamp. Caution - risk of electric shock - use in dry and damp locations only. Risk of electric shock - do not use where directly exposed to water. This device is not intended for use with emergency exit fixtures or emergency exit lights. DANGER RISK OF ELECTRIC SHOCK DISCONNECT POWER BEFORE INSTALLATION 4

SECTION 3 - Installation Instructions ENSURE POWER TO LUMINAIRE IS OFF 01 Application of Power to LED Tube Power must be applied to the endcap labeled AC INPUT, applying power to wrong end will cause a direct short of the AC power when turned on. 02 Retrofit Steps a.) Determine if the fixture has an electronic or magnetic ballast. For electronic ballasts use retrofit method A1. For magnetic ballasts use method B1. b.) Before restoring power after retrofit, use wire nuts to cover exposed end of any wires cut and not removed during retrofit procedure. A1 Retrofit luminaire with electronic ballast Choose the wiring method that best suits the fixture Remove diffuser (if applicable) and fluorescent lamp. Cut off all wires which are connected to ballast. 1.) 2.) OR Wires on both ends (sockets) of luminaire 5 Wires on one end (socket) of luminaire Connect Line and Neutral to AC INPUT according to the figure above (LED tube will not be damaged if L and N are reversed)

B1 Retrofit luminaire with magnetic ballast 1.) Choose the wiring method that best suits the fixture 2.) Remove diffuser (if applicable) and fluorescent lamp. Cut off all wires which are connected to ballast. If wiring as shown below in method 2, cut wires to starter. Bypass ballast OR Wires on both ends (sockets) of luminaire Replace standard starter with short circuit starter supplied with LED tube Wires on one end (socket) of luminaire Connect Line and Neutral to AC INPUT according to the figure above (LED tube will not be damaged if L and N are reversed) 03 Complete Installation Included label, as shown to the right, must be affixed to modified fixture in a location easily seen when replacing lamp. The Kit, Replacement Label, and Installation instructions are provided with the LED Tube. Website: superbrightleds.com Tel: 866-590-3533 Fax: 314-972-6202 Email: support@superbrightleds.com Address: Super Bright LEDs, Inc., Earth City, MO 63146, USA 6