A New Synthetic Test Circuit For the Operational Tests of HVDC Thyristor Modules

Similar documents
Operational Tests of the Three-Gorges Changzhou HVDC Thyristor Valves by Using a Synthetic Test Circuit

Electrical Test of STATCOM Valves

Reliability Enhancement of HVDC Transmission by Standardization of Thyristor Valves and Valve Testing

A novel synthetic test system for thyristor level in the converter valve of HVDC power transmission

EXPERIMENTAL VERIFICATION OF INDUCED VOLTAGE SELF- EXCITATION OF A SWITCHED RELUCTANCE GENERATOR

Voltage Sag Mitigation in IEEE 6 Bus System by using STATCOM and UPFC

Implementation of FC-TCR for Reactive Power Control

Protective firing in LCC HVDC: Purposes and present principles. Settings and behaviour. V. F. LESCALE* P. KARLSSON

Study of Fault Clearing by A Circuit Breaker In Presence of A Shunt Capacitor Bank

A Transient Free Novel Control Technique for Reactive Power Compensation using Thyristor Switched Capacitor

Wind Power Plants with VSC Based STATCOM in PSCAD/EMTDC Environment

Soft Switching of Two Quadrant Forward Boost and Reverse Buck DC- DC Converters Sarath Chandran P C 1

Modelling and Analysis of Thyristor Controlled Series Capacitor using Matlab/Simulink

DEPARTMENT OF ELECTRICAL ENGINEERING DIT UNIVERSITY HIGH VOLTAGE ENGINEERING

Benefits of HVDC and FACTS Devices Applied in Power Systems

A low loss mechanical HVDC breaker for HVDC Grid applications THOMAS ERIKSSON, MAGNUS BACKMAN, STEFAN HALÉN ABB AB, CORPORATE RESEARCH SWEDEN

Overview of Flexible AC Transmission Systems

Enhancement of Power Quality in Transmission Line Using Flexible Ac Transmission System

International Journal of Emerging Technology and Innovative Engineering Volume 2, Issue 4, April 2016 (ISSN: )

Reactive Power Management Using TSC-TCR

Design and Reliability of a High Voltage, high Current Solid State Switch for Magnetic Forming Applications

Increasing Wanzhou Power Transfer Capability by 550kV Fixed Series Capacitor FSC Fengjie

The 1,400-MW Kii-Channel HVDC System

Power Quality and Power Interruption Enhancement by Universal Power Quality Conditioning System with Storage Device

Circuits for Protecting and Triggering SCRs in High Power Converters

6545(Print), ISSN (Online) Volume 4, Issue 2, March April (2013), IAEME & TECHNOLOGY (IJEET)

Second Edition. Power Electronics. Devices and Circuits. V. Jagannathan

CIGRÉ SC B1 International Colloquium on H.V. Insulated Cables Oct 2017, New Delhi, India

Lecture 2. Power semiconductor devices (Power switches)

(by authors Jouko Niiranen, Slavomir Seman, Jari-Pekka Matsinen, Reijo Virtanen, and Antti Vilhunen)

HVDC. TMT&D provides the best and most economical HVDC system.

International Journal Of Global Innovations -Vol.2, Issue.I Paper Id: SP-V2-I1-048 ISSN Online:

INTERNATIONAL JOURNAL OF ELECTRICAL ENGINEERING & TECHNOLOGY (IJEET)

POWER TRANSMISSION OF LOW FREQUENCY WIND FIRMS

A Revolution in Circuit Breaker Operating Mechanism Technology

DC Arc-Free Circuit Breaker for Utility-Grid Battery Storage System

Research on Transient Stability of Large Scale Onshore Wind Power Transmission via LCC HVDC

Journal of American Science 2015;11(11) Integration of wind Power Plant on Electrical grid based on PSS/E

Concepts And Application Of Flexible Alternating Current Transmission System (FACTS) In Electric Power Network

SPEED CONTROL OF THREE PHASE INDUCTION MACHINE USING MATLAB Maheshwari Prasad 1, Himmat singh 2, Hariom Sharma 3 1

Modelling of Hybrid DC Circuit Breaker Based on Phase-Control Thyristors

Course Name: POWER ELECTRONICS Course Code: EE603 Credit: 4

International Conference on Advances in Energy and Environmental Science (ICAEES 2015)

Independent Testing Laboratory for High Voltage Equipment

A manufacturer s view of bushing reliability, testing and analysis. Lars Jonsson Håkan Rudegard

POWER FACTOR CORRECTION USING SHUNT COMPENSATION

DYNACOMP. The top-class reactive power compensator

B kv Gas-insulated Substations

Implementation SVC and TCSC to Improvement the Efficacy of Diyala Electric Network (132 kv).

Rotor Position Detection of CPPM Belt Starter Generator with Trapezoidal Back EMF using Six Hall Sensors

Modelling and Simulation of DFIG based wind energy system

Zero-turn-off thyristor zero voltage block media recovery analysis of influencing factors FANG Wei1, a*, XU Guo-shun1, b, ZHUANG Jin-wu1, c

Enhancement of Power System Stability Using Thyristor Controlled Series Compensator (TCSC)

Paper ID: EE19 SIMULATION OF REAL AND REACTIVE POWER FLOW ASSESSMENT WITH FACTS CONNECTED TO A SINGLE TRANSMISSION LINE

Performance study of combined test rig for metro train traction

CHAPTER 3 TRANSIENT STABILITY ENHANCEMENT IN A REAL TIME SYSTEM USING STATCOM

The Application of Power Electronics to the Alberta Grid

The Development of ±800kV/4750A UHVDC Valve & HVDC/FACTS Status in China. For EPRI HVDC & FACTS Conference Aug. 30, 2011 Palo Alto, California, USA

China. Fig. 1 Chain SVG Electrical Diagram

Power Quality Improvement Using Statcom in Ieee 30 Bus System

Pankaj Khali, ABB India Limited Representing :ABB Switzerland limited, September 2016 Generator Circuit-Breakers. Technical Seminar: PLN

Designing with SiC & GaN devices with Emphasis on EMC & Safety considerations

Okelola, M. O. Department of Electronic & Electrical Engineering, Ladoke Akintola University of Technology, P.M.B. 4000, Ogbomoso, Nigeria

Performance Analysis of Bidirectional DC-DC Converter for Electric Vehicle Application

Simulation of real and reactive power flow Assessment with UPFC connected to a Single/double transmission line

Product brochure Generator circuit-breaker HVS-63S System type GCB with innovative built-in monitoring

Tiruchengode, Tamil Nadu, India

Excitation systems for high power synchronous generators with redundant configurations

Statcom Operation for Wind Power Generator with Improved Transient Stability

A Review on Reactive Power Compensation Technologies

Impulse Voltage Test System, Q Structure, kV

Outdoor vacuum breaker for railway applications - FSK II

Experimental Investigation of Effects of Shock Absorber Mounting Angle on Damping Characterstics

Design and Simulation of Grid Connected PV System

Unified Power Quality Conditioner with Electric Double Layer Capacitor

RESEARCH OF THE DYNAMIC PRESSURE VARIATION IN HYDRAULIC SYSTEM WITH TWO PARALLEL CONNECTED DIGITAL CONTROL VALVES

BIDIRECTIONAL FULL-BRIDGE DC-DC CONVERTER WITH FLYBACK SNUBBER FOR PHOTOVOLTAIC APPLICATIONS

Powerframes - Power Electronics

Development and Analysis of Bidirectional Converter for Electric Vehicle Application

Pantograph and catenary system with double pantographs for high-speed trains at 350 km/h or higher

POWER QUALITY IMPROVEMENT BASED UPQC FOR WIND POWER GENERATION

GENERATION, CONVERSION, OR DISTRIBUTION OF ELECTRIC POWER

ABB s hybrid HVDC breaker, an innovation breakthrough enabling reliable HVDC grids

Rural electrification using overhead HVDC transmission lines

Examples of Electric Drive Solutions and Applied Technologies

FAULT ANALYSIS FOR VOLTAGE SOURCE INVERTER DRIVEN INDUCTION MOTOR DRIVE

Current accuracy class. Sensor principles

Next-generation SCADA and Control Technologies for Large-scale Use of Photovoltaic Generation on Electric Power Grid

AIR CORE REACTORS. Phoenix Electric Corporation

DESIGN AND ANALYSIS OF PRE- INSERTION RESISTOR MECHANISM

HIGH VOLTAGE, HIGH CURRENT, HIGH DI/DT SOLID STATE SWITCH

Comprehensive Analysis of Slip Power Recovery Scheme

Analysis and Design of Improved Isolated Bidirectional Fullbridge DC-DC Converter for Hybrid Electric Vehicle

International Journal of Advance Research in Engineering, Science & Technology

Resin Impregnated Paper Bushing, Oil to SF 6. , Type GSBK

International Journal of Advance Engineering and Research Development. Automatic Power Factor Correction in EHV System

Using MATLAB/ Simulink in the designing of Undergraduate Electric Machinery Courses

Shunt Capacitor Bank Protection in UHV Pilot Project. Qing Tian

Study of 345 kv Transient Recovery Voltages on the Illinois Power System

Modeling and Simulation of TSR-based SVC on Voltage Regulation for Three-Bus System

Transcription:

Paper presented at IEEE PELS APEC Conference on March -8,, at Anaheim, USA. Conf. Proceedings pp.-6 A New Synthetic Test Circuit For the Operational Tests of HVDC Thyristor Modules B.L. Sheng E. Jansson A. Blomberg H-O Bjarme D. Windmar ABB Power Syste AB ABB Switchgear AB SE-778 Ludvika Sweden Abstract Modern power thyristor valves have a high power rating and are difficult to test in a back-to-back test circuit in the test laboratory. Verification of thyristor valve design with synthetic test circuits is an alternative. The core to design a synthetic test circuit is to correctly reproduce the stresses applied on the thyristor valves. Voltage and current stresses on the thyristors under four operational states are highlighted in this paper. A new synthetic test circuit has been developed by ABB Power Syste. This new circuit reproduces the correct stresses applied on the high voltage direct current (HVDC) thyristor valves in service. Verifying tests reveal that the circuit design was a success. Keywords: HVDC, thyristor modules, operational tests, synthetic test circuit, high power laboratory, type testing I. INTRODUCTION To test thyristor valves, it has been the custom in ABB Power Syste to use a back-to-back test plant (referred as the direct test circuit in this paper) in which generators are used to supply the power for the tests. The rating of this direct test circuit is 8. / A or 5 / 5 A (U dio / I dc). The power handling capability of modern thyristors has seen a significant progress in the past twenty years. Modern thyristor valves have a high power rating per thyristor level. The direct testing power is sufficient only for testing maximum three thyristor levels. Testing of thyristors up to three levels in series per valve could cause controversy on the representation of voltage distribution on the thyristor levels during the test. Studies show that valve sections with five or more thyristor levels can be considered an adequate representation [] []. As a consequence of the increment of the number of thyristor levels under test the power rating of the test plant has to be proportionally increased. To increase the direct testing power is neither an economical nor a very practical solution. Synthetic testing is recommended by CIGRE [] as an alternative to the direct testing. Synthetic testing methods are based on the fact that the HVDC thyristor valve is stressed by current and voltage at different time intervals. The current stress occurs during the conducting interval followed by the voltage stress during the blocking interval of the valve. is, therefore, possible to apply different stresses by two separate sources at different time intervals. To ensure the equivalence of synthetic testing of HVDC thyristor valves a complete understanding of current and voltage stresses on the thyristor valve is necessary. In a synthetic test circuit these stresses should be correctly reproduced. The turn-on and turn-off are the two most critical operating for the thyristor valves. A close representation of these two states in a synthetic testing circuit ensures the testing equivalence. A joint project group between ABB Power Syste and ABB Switchgear was set up to develop and implement the new synthetic test circuit. The design of the synthetic test circuit, its operating principle, and operational tests conducted with the synthetic test circuit are described in this paper. II. VALVE STRESSES Voltage and current stresses on a thyristor valve during operation can be analyzed separately in four operational states: off-state and reverse voltage, turn-on, on-state and turn-off state[] [5] [6]. Off-state and reverse voltage: Voltage current characteristics determines the maximum permissible operational voltage. Under steady-state operating conditions the valves endure transient voltage excursions at turn-off. Another voltage stress on the valves will be the transient forward voltage during the recovery period. The thyristors must be adequately protected against the effects of these transients without unacceptably affecting the performance. Voltage jumps in the off-state and reverse voltage contribute to the losses of valve damping resistors and valve reactors. To apply the correct stress on these components the value of the complete off-state and reverse voltage waveform should equal or exceed these in service. Turn-on: A high initial di/dt passes through the thyristors due to the stray capacitance and the damping capacitor of the thyristor valve after firing. This high di/dt can give rise to excessive power density in the silicon which can cause failure through local melting.

Paper presented at IEEE PELS APEC Conference on March -8,, at Anaheim, USA. Conf. Proceedings pp.-6 To produce the right di/dt after firing correct stray capacitance and voltage on the stray capacitance before firing have to be fulfilled. Direct test circuits meet these requirements easily by scaling the valve s operational parameters to test sections. However, in a synthetic test circuit attention has to be paid to the circuit layout to achieve the real turn-on stress. On-state: At turn-on the thyristors become conducting and produce conduction losses. The conduction losses will result in an increase of the junction temperature, which may deteriorate the voltage blocking capability of the thyristor. To verify the thermal performance of thyristors, correct amplitude and duration of conducting current are of special importance. Turn-off: After turn-off the valve withstands a transient recovery voltage with a voltage overshoot and subsequently power frequency recovery voltage. The transient recovery voltage is not only controlled by the main circuit and damping circuit but is also influenced by the recovery charge of the thyristors. The overshoot is the result of interaction between the main circuit, damping circuit and recovery charge in thyristors. Fig.. View of six-pulse back-to-back bridges and test object is fundamental to correctly reproduce the current and voltage stresses on the test object in all four operational states above. By adjusting test circuit parameters the conditions for above four operational states should be achieved. Special consideration has to be paid to the di/dt at turn-off since it affects the recovery charge of the thyristors. III. THE SYNTHETIC TEST CIRCUIT A. Circuit Description The diagram of the synthetic test circuit is given in Figure. Two sources (current source and voltage source) supply the test current and voltage alternately to the test object (V t) by the help of several auxiliary thyristor modules (V a to V a5). C t represents the stray capacitance and L represents the commutation inductance in service. Both C t and L are scaled from service condition. V a V a L L V a Current Source V t V a C t C s Fig.. The synthetic test circuit V a5 Voltage Source Fig.. Capacitor banks of the voltage section The current section consists of two six-pulse bridges connected in back-to-back mode (one bridge as rectifier and the other as inverter). Two six-pulse bridges, valve units for short circuit testing, auxiliary valve V a and test object V t are assembled in one mechanical structure as shown in Figure. The whole structure is suspended from the ceiling of the test hall and the test object V t is located at the bottom of the structure. Auxiliary valve V a and the test object V t are one

Paper presented at IEEE PELS APEC Conference on March -8,, at Anaheim, USA. Conf. Proceedings pp.-6 arm of the rectifier. A low bridge voltage is used in the current source. Corresponding to this low bridge voltage a low commutation inductance is selected in order to keep the right commutation overlap. The current source voltage is high enough to generate the requested short-circuit current. The voltage section comprises of a DC voltage source, one capacitor bank C s, two reactor banks L and L and auxiliary valves V a to V a5 as shown in Figure. The capacitor banks used to configure the voltage section of the synthetic test circuit are shown in Figure. The DC source is continuously adjustable up to 7. The inductance of reactor bank L can be adjusted between. mh to maximum mh. The capacitance of capacitor bank C s can be adjusted between.9 µf to 7 µf. Forward and reverse voltages are formed by firing auxiliary valves at specific instants. The output voltage level of the DC source controls the voltage amplitude. An impulse generator is also included in the voltage section (not shown in Figure ). The impulse generator is connected to the high potential terminal of test object when tests of transient voltage during the recovery period are performed. B. The Operating Principle of the Synthetic Test Circuit The operating principle of the synthetic test circuit is illustrated in Figure and described as follows: As one arm of the six-pulse bridge, V a and V t conduct a current representing the service current (t to t in Figure ). The current source has a reduced driving voltage. Shortly before the load current I d (from the current source) in V t reaches its zero (t ) the positive charge in C s is released by firing V a at t. The injection current of the voltage circuit extinguishes V a at t and isolates the current source until firing V a in the next period. V t conducts the injection current alone about 6µs (adjustable) after the main current zero. The injected current is of a sinusoidal waveshape. L is a key component and is selected to be representative of the phase-to-phase commutating inductance of the real circuit. C s in conjunction with L is selected to have the half wave injection time (t to t ) equal to or higher than 6 µs []. The pre-charged voltage on C s together with the inductance of L will give a close representation of the service current in the interval µs before current zero (t ). V t blocks at the injected current zero. The voltage on C s has been reversed to a value U (slightly lower than U, due to losses, Figure ) after the half wave injected current. This reversed voltage charges C t through the loop C s V a L C t by firing V a to form the transient recovery voltage and reverse recovery voltage (t to t 5). V a5 and V a are fired at t after the transient recovery voltage has been damped out to reverse the voltage on C s. The voltage applied on C t and V t changes its polarity correspondingly from U to U (t to t 6). V a is fired at t 7 in order to allow current (I ch in Figure ) from the DC charger to compensate the voltage drop on C s. V a is blocked by the reverse oscillating current after C s is fully compensated at t 8. V t is fired at t 9 from the forward voltage U. The capacitor C t, which was charged to the same voltage level, will then be discharged through V t to produce the early inrush current as in service. The firing of V t collapses the voltage between its terminals and results the current source voltage apply on the V a. Following the firing of V t the isolation valve V a is fired to release the output of the high current source through V a and the test object V t. U, I I d I inj U Fig.. Current and voltage relationship on the test object C. Control of Synthetic Test Circuit The control and protection of the synthetic test circuit are governed by ABB s MACH system. A number of firing timings of the test object and auxiliary valves are pre-defined in the firing sequences. The firing sequence and each individual timing are continuously adjustable during the tests if necessary. The width of the firing pulse is adjustable from µs to. The firing timing has an accuracy of µs. The programmed test sequences combine the current and voltage order with the firing sequences of the test object and the auxiliary valves, together with the test duration. The control system includes also the control/monitoring of the temperature and flow of the cooling media in each individual valve. A graphical operator interface of MACH provides an easy access to utilize above functions and to make the connection of main circuit permissible remotely. IV. VERIFYING TESTS In order to verify the synthetic test circuit the following tests have been performed: Periodic firing and extinction tests, intermittent direct current, minimum a.c. voltage tests, transient forward voltage test during thyristor recovery period I rev U U t t t t t t t 5 t 6 t 7 t 8 t 9 Ich I d

Paper presented at IEEE PELS APEC Conference on March -8,, at Anaheim, USA. Conf. Proceedings pp.-6 and fault current test with re-applied forward voltage. The test object V t consists of two complete thyristor modules (twelve thyristor levels) and two saturable reactors. A general current and voltage waveshape under periodic firing and extinction tests is shown in Figure 5. With this basic waveshape, operational tests corresponding to different service conditions could be realized by adjusting the output voltage level of the DC source. To represent the operational mode of α=9 ο the test object has to be fired twice in one cycle as shown in Figure 6. One extra injection current will pass through the test object by this double firing. This extra injection current gives the test object extra conduction losses. These extra losses are negligible compared to the total losses. The reverse and forward voltages are of the same value (under no losses assumption) in the test circuit. This gives a higher reverse voltage under maximum continuous firing voltage test or a higher forward voltage under maximum continuous recovery voltage test. When heat-run test is performed, attention has to be paid to the determination of voltage level of the voltage source. The voltage should be equal or higher than the value that could result in the same losses as in service. With separated current and voltage sources in the synthetic test circuit, the efficiency of impulse generator is greatly increased. This technical merit gives the feasibility of applying the impulse transient voltage on the test object by a conventional impulse generator. The front time of impulse can be adjusted from µs to 7 µs in the test circuit. Figure 7 is the test record of transient forward voltage test during thyristor recovery period. Transient impulse voltage has a front time of µs in this test. k/div - k/div - - k/div - 78 8 8 8 86 88 9 9 9 96 98 /div Fig. 6. Periodic firing and extinction test (α = 9 ο ) - 9 6 k/div - -6 -.5 -.5 -.5.5.5.5.5.5 5.5 /div Fig. 7. Test with transient voltage during the recovery period 8 I 7 k/div 7 k/div -7 -.5 k/div - Ut k/div - - - -6 - -7 - -7-8 8 8 5 /div -5 5 5 5 /div Fig. 5. Periodic firing and extinction tests Fig. 8. One-loop fault current with re-applied forward voltage A test oscillogram of one-loop fault current with re-applied forward voltage test is given in Figure 8. No transit time is necessary from normal to short-circuit operation in the synthetic test circuit. The capabilities of the synthetic test circuit to perform other operational test duties have been verified in the verifying tests too. These test duties include multiple-loop fault current test without re-applied forward voltage, intermittent direct current and minimum AC voltage tests.

Paper presented at IEEE PELS APEC Conference on March -8,, at Anaheim, USA. Conf. Proceedings pp.-6 The tests show that the synthetic test circuit, in conjunction with direct test circuit, can cover all the test duties specified in the operational tests of HVDC thyristor valves by IEC and IEEE Standards [] []. The test circuit correctly supplies the direct current in the current interval and applies the recovery voltage in the voltage interval on the test object. V. CONCLUSIONS Synthetic testing method is an economical and efficient way to verify modern HVDC thyristor valves. The possibility of test circuit parameter adjustment of the synthetic circuit gives more flexibility to perform different HVDC valve tests. Independent control of test current and voltage by two different sources provides close and flexible stress reproduction. By proper design the synthetic test circuit can correctly reproduce the current and voltage stresses on the thyristor valve. As a result of the theoretical and laboratory investigations, a new synthetic test circuit for the operational tests of HVDC thyristor valves is introduced. This circuit shows its superiority by: test current from a six-pulse bridge correct stress reproduction, especially at two critical instants (turn-on and turn-off), of valve operation no transit time from normal to short-circuit operation large number of series connected thyristor levels under test simplicity in circuit configuration REFERENCES [] IEC 67- ( 998 ): Thyristor valves for high voltage direct current ( HVDC ) power transmission - Part : Electrical testing [] IEEE Std 857-996: IEEE Recommended Practice for Test Procedures for High-Voltage Direct-Current Thyristor Valves [] Task Force of Working Group.: Test Circuits for HVDC Thyristor Valves ; CIGRE Technical Brochure [] Task Force of Working Group.: Voltage and current stresses on HVDC valves ; ELECTRA No.5, July 989 [5] P.C.S. Krishnayya: Important Characteristics of Thyristors of Valves For HVDC Transmission and Static Var Compensators ; CIGRE 98 Session - [6] N.J.Bergsjö and S.Sturesson: Quality Control of Highpower Thyristors ; ASEA Journal 976 Volume 9 Number BIOGRAPHIES B.L. Sheng ( Sheng Baoliang ) was born in Changchun, China in 96. He obtained his B.Sc degree in 98 from Xi an Jiaotong University, China, and his Ph.D. in 995 from Delft University of Technology, the Netherlands, both in electrical engineering. From 98 to99 he worked at National High Power Laboratory ( XIHARI ), China, as a test engineer and research engineer. He worked at KEMA as a research engineer and towards his Ph.D. at Delft University of Technology from 99 to 996. He joined the High Power Laboratory of ABB Switchgear AB, Sweden, in May 996 as a research and development engineer. He was appointed as Company Specialist in the field of High Power Testing of Electrical Power Equipment in January 999. He joined ABB Power Syste AB in September as a research and development engineer for the electrical design of HVDC and SVC thyristor valves. He is the designer of this new synthetic test circuit. E-mail: baoliang.sheng@se.abb.com Erik Jansson was born in Karlstad, Sweden in 967. He obtained his Master degree in 99 from Uppsala University, Sweden. He joined ABB Power Syste AB in 99 as a research and development engineer in the electrical design department of HVDC thyristor valves. He was the project manager to develop and implement the synthetic test circuit in the testing laboratory. He is the manager of Development of Control and Protection Department at present. E-mail: erik.jansson@se.abb.com Anders Blomberg was born in Enköping, Sweden in 97. He graduated from Mälardalens Universirty, Sweden, with a Bachelor degree in electrical engineering in 997. He joined ABB Power Syste AB in the same year as a testing engineer for the test of HVDC thyristor valves. He has worked with computer simulation and electrical design of the synthetic test circuit. E-mail: anders.l.blomberg@se.abb.com Hans-Ola Bjarme was born in Stockholm, Sweden in 99. He obtained his Master degree from Royal Technical University, Sweden in 976. He was a college lecturer in Stockholm from 977 to 98. He joined ASEA in 98 as a research and development engineer. From 99 to 995 he had been with STRI (Swedish Transmission Research Institute) as a research scientist and project manager. From 995 to 997 he was a development engineer in ABB Power Transmission, Australia. Since 997 he has been working in ABB Power Syste AB as the manager of Thyristor Valve Electrical Design Department. He is member of IEC working group IEC F MT9. E-mail: hans-ola.bjarme@se.abb.com Dan Windmar was born in Strängnäs, Sweden in 96. He obtained his Bachelor degree in physics in 989 and his Ph.D. in 99 from Uppsala University, Sweden, in electrical engineering on the topic of transients and electrical discharges. From 99 to 999 he worked at ABB Corporate Research as a research scientist and department manager especially studying high voltage insulation syste. He joined ABB Switchgear AB in May 999 as the manager of the High Power Laboratory. He is active in working groups within CIGRÉ and is the chairman of SATS, the Scandinaivian Association for Testing of Electrical Power Equipment. E-mail: dan.windmar@se.abb.com 5