Development of Electrical Power System Simulator.

Similar documents
Power Systems Trainer

Advanced Protective Relay Training

Planning for a Power Engineering Institute

4-Day Power System Analysis, Coordination, System Studies

Electrical Power Systems 2014/15

ISO Rules Part 500 Facilities Division 502 Technical Requirements Section Interconnected Electric System Protection Requirements

ELG4125: Flexible AC Transmission Systems (FACTS)

Legal Name of the Customer (or, if an individual, individual's name): Name: Contact Person: Mailing Address: Physical Address: City: State: Zip Code:

GENERATOR INTERCONNECTION APPLICATION

Performance Analysis of Transient Stability on a Power System Network

RULE 21 GENERATING FACILITY INTERCONNECTION APPLICATION SMUD s Distribution System - (SMUD FORM 2655)

CUSTOMER / ACCOUNT INFORMATION Electric Utility Customer Information (As shown on utility bill)

CHAPTER 6 DESIGN AND DEVELOPMENT OF DOUBLE WINDING INDUCTION GENERATOR

CATEGORY 2 GENERATOR INTERCONNECTION APPLICATION

Electric Utility Contact Information Indiana Michigan Power

UNC-Charlotte's Power Engineering Teaching lab

Journal of American Science 2015;11(11) Integration of wind Power Plant on Electrical grid based on PSS/E

Computer Aided Transient Stability Analysis

EH2741 Communication and Control in Electric Power Systems Lecture 3. Lars Nordström Course map

SECTION 9: ELECTRICAL POWER DISTRIBUTION. ESE 470 Energy Distribution Systems

Enhancement of Power Quality in Transmission Line Using Flexible Ac Transmission System

IEEE Guide for the Design of Low Voltage AC and DC Auxiliary Systems for Substations

Study of Fault Clearing by A Circuit Breaker In Presence of A Shunt Capacitor Bank

PSNH INTERCONNECTION REQUEST

PID 274 Feasibility Study Report 13.7 MW Distribution Inter-Connection Buras Substation

VOLUME: IIIC SCHEDULE IIIC/4 11 KV AND 3.3 KV SWITCHGEARS

NORTH CAROLINA INTERCONNECTION REQUEST APPLICATION FORM. Utility: Duke Energy Progress

Final User Smart Grid Trainer AEL-FUSG

Induction Generator: Excitation & Voltage Regulation

TECHNICAL SPECIFICATION FOR INDEPENDENT POWER PRODUCERS. NB Power Customer Service and Distribution. June 2008

Standby Power Systems

ELECTRICAL POWER and POWER ELECTRONICS

Effect of prime mover speed on power factor of Grid Connected low capacity Induction Generator (GCIG)

INTRODUCTION. Technological limitations on metering no longer force peak power prices to be averaged out and passed on to all consumers equally.

Maryland Level 2, Level 3 & Level 4 Interconnection Request Application Form (Greater than 10 kw to 10 MW or less)

GE Energy. Variable Frequency Transformers Grid Inter-tie

Chapter 6 Generator-Voltage System

CONTROL AND PERFORMANCE OF A DOUBLY-FED INDUCTION MACHINE FOR WIND TURBINE SYSTEMS

Dynamic Behaviour of Asynchronous Generator In Stand-Alone Mode Under Load Perturbation Using MATLAB/SIMULINK

Power Quality and Power Interruption Enhancement by Universal Power Quality Conditioning System with Storage Device

Using MATLAB/ Simulink in the designing of Undergraduate Electric Machinery Courses

Laboratory Experiments for Enhanced Learning of Electromechanical Devices

ELECTRIC MACHINES EUROLAB 0.3 kw

34 th Hands-On Relay School

Control System for a Diesel Generator and UPS

CHAPTER 3 TRANSIENT STABILITY ENHANCEMENT IN A REAL TIME SYSTEM USING STATCOM

(by authors Jouko Niiranen, Slavomir Seman, Jari-Pekka Matsinen, Reijo Virtanen, and Antti Vilhunen)

DISTRIBUTED GENERATION FROM SMALL HYDRO PLANTS. A CASE STUDY OF THE IMPACTS ON THE POWER DISTRIBUTION NETWORK.

SYSTEM INTEGRATION. Railway and urban transport electrification Energy-efficient and reliable solutions

Laboratory Tests, Modeling and the Study of a Small Doubly-Fed Induction Generator (DFIG) in Autonomous and Grid-Connected Scenarios

Performance Analysis of 3-Ø Self-Excited Induction Generator with Rectifier Load

Power System Stability Analysis on System Connected to Wind Power Generation with Solid State Fault Current Limiter

INTERCONNECTION STANDARDS FOR PARALLEL OPERATION OF SMALL-SIZE GENERATING FACILITIES KILOWATTS IN THE STATE OF NEW JERSEY

Figure 1. Two and Three-phase MagneX.

PJM Generator Interconnection Request Queue #R60 Robison Park-Convoy 345kV Impact Study September 2008

A Electric Power / Controls ELECTRIC POWER TECHNOLOGY 0.2 kw

Summary of Revision, IEEE C , Guide for Breaker Failure Protection of Power Circuit Breakers

Universal Interconnection Technology Technology Roadmap Workshop. Associated Barriers to Distributed Generation

PV Grid Integration Research in the U.S.

Transformer Protection

School of Technology, Energy & Apprenticeship. Advanced Power Engineering Program. Course Outline fall 2014

Guideline for Parallel Grid Exit Point Connection 28/10/2010

Aswan high dam - Distributed control system AUTOMATION

DYNAMIC BEHAVIOUR OF SINGLE-PHASE INDUCTION GENERATORS DURING DISCONNECTION AND RECONNECTION TO THE GRID

Targeted Application of STATCOM Technology in the Distribution Zone

Next-generation SCADA and Control Technologies for Large-scale Use of Photovoltaic Generation on Electric Power Grid

COMPARISON OF DIFFERENT SOFTWARE PACKAGES IN POWER FLOW AND SHORT-CIRCUIT SIMULATION STUDIES. A Project

ES09 ELECTRICAL MACHINES TECHNICAL SPECIFICATIONS

Integration of Large Wind Farms into Electric Grids

INTRODUCTION. AC motor operations, most widely used motor is three phase induction motor. This type of motor does not require any starting device

Synchronous motor control. 8/15/2007 Powerflow Technologies Inc 1

Electrical Theory. Generator Theory. PJM State & Member Training Dept. PJM /22/2018

Application of AC Three-Phase Induction Motor of Wound Rotor AEL-ACWRA

EPE97 OPTIMIZED DESIGN OF VARIABLE-SPEED DRIVES BASED ON NUMERICAL SIMULATION

Interconnection Feasibility Study Report GIP-226-FEAS-R3

J.-J.Simond*, A.Sapin**, B.Kawkabani*, D.Schafer***, M.Tu Xuan*, B.Willy***

Use of STATCOM for Improving Dynamic Performance of Wind Farms Connected in Power Grid

GENERATION, CONVERSION, OR DISTRIBUTION OF ELECTRIC POWER

Michigan State University Construction Standards SECONDARY UNIT SUBSTATIONS PAGE

The University of New South Wales. School of Electrical Engineering and Telecommunications. Industrial and Commercial Power Systems Topic 6

Static frequency converter couples US paper mill s 25-Hz and 60-Hz electricity grids

CHAPTER 5 FAULT AND HARMONIC ANALYSIS USING PV ARRAY BASED STATCOM

e t Electronics Based Dump Load Controller (DLC) for an Grid Isolated Asynchronous Generator (GIAG)

TRANSMISSION SYSTEMS

Renewable Energy Systems 14

IEEE-PES Chicago Chapter Presentation November 11, Smart Grid. Mike Born. Principal Engineer, Capacity Planning

Sl. No. Subject Description Level of Study 01 Power Different types of converters, inverters. 6 th Sem Electronics 02 Power System I& II

AE105 PRINCIPLES OF ELECTRICAL ENGINEERING JUNE 2014

C1000 Series Automatic Cap Bank

Reactive Power Compensation using 12 MVA Capacitor Bank in 132/33 KV Distribution Substation

Date Issued: 10 August 2009 Status: ISSUED Review Date: 10 August 2011 Ref: NS5.3 DISTRIBUTED GENERATION TECHNICAL REQUIREMENTS TABLE OF CONTENTS

Enhancement of Transient Stability Using Fault Current Limiter and Thyristor Controlled Braking Resistor

Powerframes - Power Electronics

Designing and Maintaining a Pollution-Resilient Electric Power System. Managing Pollution Issues

Experience on Technical Solutions for Grid Integration of Offshore Windfarms

Powerframes - Power Electronics

Modular Standardized Electrical and Control Solutions for Fast Track Projects

SINAMICS SM150. 4/2 Overview. 4/2 Benefits. 4/2 Design. 4/6 Function. 4/8 Selection and ordering data. 4/8 Options

Development and Operational Advantages of a Solid State Circuit Breaker with Current Limiting

Issues for connection of distributed generation in rural/remote power systems

Transcription:

Development of Electrical Power System Simulator. G. Adedokun, M.Eng., MNSE, R.Eng. Department of Electrical/Electronics Engineering, Osun State College of Technology, Esa-Oke, Nigeria * E-mail: adedokun_gb@yahoo.com ABSTRACT This paper describes how to utilize an electric power system simulator (PSS) as a useful instrument for teaching power flow studies in a power laboratory at the undergraduate level. An analogue PSS has been developed at Osun State College of Technology Esa-Oke, Nigeria. This provides a user friendly environment that allows students to simulate and analyze events that occur on an electric power network. These events consist of changing the bus voltages at the generating stations, taking generating stations offline, and taking transmission lines out of service. After each event the students calculates the voltage at each bus, and the real and reactive power flow through the system. The user can then analyze the change in these values because of the event. The completely self-contained teaching module for class and project work is provided as a supplement for practical teaching aid in electrical power system. This has increased students' ability to understand the way a power system responds to various loads and generation schedules. Examples of simulations are included. (Keywords: electric energy, power system, simulation, equipment, instrument, generation, transmission, distribution, load, sub-station, high-voltage, substation, transformer, excitation system, grid, prime-mover) INTRODUCTION Electric energy is the most popular form of energy as it can be transported easily at high efficiency and reasonable cost. The only system that can process this phenomenon is the electric power system. An electric power system is defined in the I.E.E. Regulation as a complex interconnection of simple electric devices (represented by active and passive elements) in which there is at least one closed path for the flow of current [1]. All electrical engineering students must be oriented on how to process electrical energy during their course of training with the aid of equipment otherwise known as electrical power system simulator (PSS) installed in the school power laboratory. The system (PSS) is a selfcontained unit that simulates all parts of electrical power systems and their protection, from generation to utilization points [2]. The PSS consist of four major parts (sections), namely: Generation Transmission and sub transmission Distributions Load Each section includes dedicated industrial standard protection relays that perform specific functions, from generator protection to distance protection on the transmission lines, and distribution transformer protection. Hereunder, therefore, is an updated summary of the major sections [5]. GENERATOR AND GRID SUPPLY The generator is one of the essential components of PSS which is known as a three phase AC synchronous alternator. This machine has two synchronous rotating fields, one of which is produced by the rotor driven at synchronous speed and excited by DC current provided by the exciter and the other field is produced in the stator winding by the three-phase armature currents. The excitation system maintains alternator voltage and control the reactive power flow. However, the lack of commutator results to production of high power at high voltage level [3]. The source of mechanical power (prime mover) is an electric motor and the two machines are used to simulate power generation. This set has characteristics similar to industrial turbine and alternator sets for realistic experiments. The The Pacific Journal of Science and Technology 114

output of the generator passes through a generator transformer to a generator bus. The PSS includes a fully monitored and protected grid supply transformer. This transformer simulates the larger grid transformers used in national grid supply systems. The grid transformer reduces the incoming mains supply to give the correct distribution voltage bus. It also allows students to correctly synchronize the generator output to the grid supply. For realistic texts, students can use the grid supply on the generator as a power source for their experiments. TRANSMISSION AND SUB-TRANSMISSION The purpose of a transmission network is to convey electric energy from the generating unit to the distribution network which ultimately supplies the load. Figure 1 shows a typical layout of a transmission and distribution system. High voltage transmission line is terminated in substation, which is called high-voltage substation or primary substation. The function of this station is switching circuit in and out of service and it is referred to as a switching station. At the primary substation, the voltage is stepped down to a value more suitable to the text part of the journey toward the load. Very large industrial customers may be served from the transmission system. The portion of transmission system that connects the high-voltage substation through step-down transformer to the distribution sub station is called the sub transmission network. Capacitor banks and reactor banks are installed in the substation for maintaining the transmission line voltage. A set of reactance simulate transmission lines of different lengths to simulate overhead or underground power cables. Each line includes test points to monitor the conditions along the lines. The user can simulate faults at different places along the transmission lines and discover the effects. A dedicated distance protection relay protects the lines and can indicate how far along the line the fault has occurred. Figure 1: Components of Power System Simulator The Pacific Journal of Science and Technology 115

ENERGY CONTROL CENTER For reliable and economical operation of the power system it is necessary to monitor the entire system in a control center. The modern control center is called the Energy Control Center (ECC). An ECC is equipped with on line computers performing all signal-processing through the remote acquisition system. The computers work in a hierarchical structure to properly coordinate different functional requirements in normal as well as emergency conditions. ECCs contains a control console of a Visual Display Unit (VDU), keyboard, and light pen. The computer may give alarms as advance warnings to the operators (dispatchers) when deviation from the normal state occurs. The dispatcher makes judgments and decisions and executes them with the aid of a computer. Simulation tools and software packages written in high level language are implemented for efficient operation and reliable control of the system. This is referred to as SCADA, an acronym for supervisory control and data acquisition [4]. TRANSFORMATION, DISTRIBUTION, AND UTILIZATION In addition to the grid supply and generator transformers, the power system simulator has two identical distribution transformers fitted near to factories or houses. These transformers have variable tappings and feed a utilization bus. Dedicated relays protect the transformers and can work in different ways, determined by student experiments. The utilization bus simulates electrical consumers (houses and factories). It includes variable resistive, capacitive, and inductive loads, with an induction motor (dynamic) load. A switched bus bar section includes a main, bus and a standby bus. These simulate a real busswitching system in a power plant or power distribution station. Protection relays and contact breakers monitor and switch the incoming and outgoing feeders of the busbar. Figure 2: Power System Simulator (PSS): A Self-Contained Unit, which Simulates all Parts of the Electrical Power Network and their Protection, from Generation to Utilization points. The Pacific Journal of Science and Technology 116

One feeder of the busbar has a point-on-wave circuit-breaker for studies of switching transients [3]. TEST POINTS, TRANSDUCERS AND FAULT SWITCHES All of the important circuits have test points connected to a set of test sockets. The students can link out these sockets or connect them to other test equipment. A set of transducers allows students to connect the test sockets to an oscilloscope (supplied) for transient measurements. There are two fault switches to apply faults to different parts of the power system simulator. One fault switch is a standard three-phase switch; the other is a timed circuit is a standard three-phase switch; the other is a timed circuit breaker with a digital timer to set a precise fault duration [3]. PROTECTION RELAYS AND INSTRUMENTS All parts of the PSS include industrial-standard protection relays. The relays show students how actual power systems are protected and the difference ways that they are protected. The students can set the relays from their control panels. The more complex relays also include sockets to link them to a suitable computer (computer not included) for more detailed programming identification. The relays operate the circuit-breakers around the PSS. The circuitbreaks also include hand-operated switches, and lamps. The lamps show weather the circuitbreaker is open or closed. Multi-function digital meters connect to all the important circuits to show the conditions of all three phases. A phase-angle meter shows the phase difference between any two voltages connected to it. Moving coil meters show the frequency, power factor, voltage, current, energy and power. STANDARD FEATURES Supplied with comprehensive user guide Three-year warranty Made in accordance with the latest European Union directives EXPERIMENTS Transmission, distribution and utilization: Load flow Symmetrical faults Unbalanced faults Unsymmetrical faults Circuit interruption Generator: Synchronization Characteristics and performance Voltage variation and control Voltage regulation Stability studies Transformer: Unequal taps Unequal impedances Unbalanced loads Over current protection: Relay grading Auto-reclose High-set instantaneous Back-tripping Directional; control General protection: Phase fault Earth fault Distance protection Differential protection of generators Bus-bar protection Generator protection Recommended Ancillaries Power system simulator SCADA package (PPS2) (*SCADA = Supervisory control and Data Acquisition). This is a computer, a printer, and communication hardware, with industrial-standard software that communicates with the relays and other instruments of the power system simulator. It allows students to remotely monitor and control the different parts of the PSS1. Second Generator (PSS3) This is a console that contains a duplicate of the prime mover and generator fitted in the PSS1, but includes added features and protection relays for extra experiments in embedded and central generation. The Pacific Journal of Science and Technology 117

Note: the second generator is only for use with the power system simulator. ESSENTIAL SERVICES Electrical supply: Three-phase 10 kw, 50Hz Floor space needed: Approximately 6 m x 3 m of solid, level floor OPERATING CONDITIONS Operating environment: Laboratory environment Storage temperature range: -250C to + 550C (when packed for transport) Operating temperature range: +50C to + 400C Operating relative humidity range: 80% at temperatures < 310C decreasing linearly to 50% at 400C Sound levels: Less than 70 db (A) SPECIFICATIONS Net Dimension: 5100 mm long (plus an additional 500 mm to the right of the cabinet for power connections) 1500 mm front to back (plus an additional 1.5 m at the back when the access doors are open) 2000 mm high 2860 kg net weight Packed volume and weight: 21.74 m3 and 3530 kg Simulator Voltages: Distribution 220 V three-phase line to line Utilization 110 V three-phase line to line Grid Transformer: Delta to star 5 KVA (Dy11) transformers Primary is matched to the incoming threephase supply to give the 220 V three-phase line-to-line secondary distribution voltages. Includes earth-link for the secondary star point and a selectable tapping earth resistor for restricted earth fault protection tests. Generator and Prime Mover: 6 KVA maximum (operated at a normal 2 KV), four-pole salient pole AC generator Brushless, with automatic and manual excitation. KVA maximum induction motor with shaft encoder and electronic four-quadrant AC vector-drive inertia control, with a fourposition drive inertia switch Generator Transformer: 1:1 ratio delta-to-star (Dy 11) impedance matching with adjustable secondary tapping Transmission Lines: Line reactances simulate per unit (p.u) values of impedance: Line 1:0. 10 pu Lines 2 and 3:0.15 pu Lines 4 and 5: 0.25 pu Line 6: 5 x 0.1 pu length with four test points and dedicated three-zone distance protection Line 7 :4 0.01 pu (cable) Capacitors are provided adjacent to the lines. Each capacitor ha selectable values and may be inserted in circuit to give π or T-line configurations for studies of closes. Distribution Transformers: Two identical 2 KVA transformers, 220 V to 110V star-to-delta Yd1 Adjustable primary tappings and matched impedances Switch Busbar: Six bi-directional feeders, each with circuitbreakers-one circuit breaker is a point-onwave device Two circuit-breakers to break each half of each bus Twelve bus isolators, six on each half of the bus Two circuit-breakers that break the coupling between the main and reserve bus. Protection Relays: Grid transformer protection Grid bus protection Generator protection Generator bus protection Distance protection 2 x double bus protection 4 x distribution transformer protection The Pacific Journal of Science and Technology 118

Loads: Two separate 220 V (distribution) loads, each with delta-connected variable resistors and inductors; one load is near to the generator and the other near to the distribution bus. Two sets of 110 V (utilization) loads at the utilization bus; each has delta-connected variable resistors, inductors and capacitor banks. One dynamic load an induction motor at the utilization bus. CONCLUSIONS In this paper, an easy-to-use power system simulator designed to be used as an educational aid is presented. Power system simulation has proven to be an effective tool for learning the behavior of power system under various operating conditions and configuration. Its scope is limited, but this introduction gives the students a better understanding the aspects of power system control and motivates them to learn more about power systems. ABOUT THE AUTHOR Gbadebo Adedokun holds a B.Eng. and an M.Eng. in Electrical Engineering from the University of Ilorin, Nigeria. He is a member of Nigeria Society of Engineers. He is also a registered engineer with COREN. His areas of interest include development of programs to predict faults on electrical power networks and bifurcation analysis on electrical power networks. Presently he is a Lecturer in the Department of Electrical Engineering, Osun State College of Technology, Esa-Oke, Nigeria. SUGGESTED CITATION Adedokun, G. 2010. Development of Electrical Power System Simulator. Pacific Journal of Science and Technology. 11(1):114-119. Pacific Journal of Science and Technology Future improvements could consist of modeling capacitor banks that the user could put on and take off the system, allowing the load to be adjustable at the PSSs, and incorporating tie lines with other power systems. Modeling a transformer with tap changers that would allow the user to adjust the voltage on the low side would also be an interesting and useful addition. REFERENCES 1. Buchner, P. and Nehrir, M.H. 1991. A Block- Oriented PC-Based Simulation Tool for Teaching and Research in Electric Drives and Power Systems. IEEE Transaction on Power Systems. 6(3). 2. Gray, P.E. and Kuziej, G.P. 1993. Computer Simulation and Circuit Analysis. IEEE Transaction on Education. 36(1). 3. Saadat, H. 2002. Power System Analysis (4th Ed.). McGraw Hill: New York, NY. 4. Microsoft Corporation. 1991. Microsoft Visual Basic Language Reference. Microsoft: Redmond, WA. 5. Stevenson, W.D. 1982. Elements of Power System Analysis (4th Ed.). McGraw Hill: New York, NY. The Pacific Journal of Science and Technology 119