Free Fall Fire Valve Range & Accessories

Similar documents
Central Battery Systems Loadstar AC/DC Systems

PSU EN54-4 Power Supplies

Black Teknigas. Powerseat Eco Gas Safety Shut-Off Valve. Technical, Installation and Maintenance Details. WattsIndustries.co.uk

27.6 Vdc 1 Amp Switch Mode Power Supply for Fire EN54-4:1997 +A1 +A2

TransShield Mode 1/2. Transfer Stainless Steel Sliding Plate Fire Dampers.

24V 3A EN54 Ancillary Power Supply

Motorised Valve Range

PREMIER POWER PACK INSTRUCTION MANUAL EN54-4 POWER SUPPLY UNIT INSTRUCTION MANUAL. GLT.MAN-138 Issue: /05/2016 N.R.P.J.

RE-PR3-E-86&105 3-Phase Panel Mount 86 and 105kW

HE-PSU(4.0) Power Supply & Battery Charger Installation, Commissioning & Operating Manual

Installation & User Instructions

EC200 ELECTRONIC CONTROL SYSTEM

PRECISION UK Ltd DUPLEX AGSS PLANT

AC Rectifiers for use with Armature Actuated Brakes. Product Overview. Full Wave. Half Wave. Combination Full and Half Wave. TOR-AC Full and Half Wave

Tekn gas Black Tekn gas Black Tekn gas Black Tekn gas Black Tekn gas Black Tekn gas Black Tekn gas Black Tekn gas Black

Design Standard. Purpose: Design Standard:

FIREGARD GILBERTS. Curtain Fire Dampers FEATURES

Q Range Watertight Single-Phase Electric Quarter-turn Actuators for part-turn valves and dampers

TABLE OF CONTENTS DISCLAMER

OEM Emergency Portfolio. Product Guide. Emergency components for LED, fluorescent and auxiliary purpose

Dycon D2430 EN54-4 Fire Alarm Power Supply Series

5000 SERIES POWER SUPPLY/CHARGERS INSTALLATION GUIDE

EC400 Power Control System

FIREGARD GILBERTS. Curtain Fire Dampers FEATURES DAMPERS 4 SFB (57.9) X UDC AUGUST 2006

FUSERBLOC Fuse combination switches with rear connection for industrial fuses up to 400 A

K25000 & KD25000 Series

Manual for Inverter system type PCI05

Phoenix Inverter

Installation Instructions

RE-PR1-F 1-Phase Din-Rail Mount 1.5, 3 & 6kW

EC225 Power Control System

LATEST ARRIVALS CATALOGUE STOCK

MCD Pump Application Module

ATyS d M Remotely operated Transfer Switching Equipment from 40 to 160 A

CORROSION RESISTANT IN LINE FLOW SWITCHES

Storage Temp. ( C) Red D. Current DC (ma) Voltage Vac/dc

EMEX Power. EMEX Power. Modular AC/AC Central Battery System. EMEX Power

The 4HR-UPS 220V ac output is provided via a Pure Sine Wave inverter, allowing it to be backed up by 2x 12V standby batteries.

ARCHITECTURAL CONTROL SYSTEMS, INCORPORATED ST. LOUIS, MISSOURI

Switches Section 1. Load Break Switches. Accessories for Load Break Switches. 4 Pole Part Price Each Reference

331-SV. User Manual THREE PHASE DUPLEX LIFT STATION CONTROL PANEL WITH STATIONVIEW CONTROLLER. Ashland, OH

REVISED ATM72 Auto Transfer Module

Emergency Lighting Products Limited

ACSI MODEL 1406BB-04-AO POWER SUPPLY INSTALLATION INSTRUCTIONS

xboard safety, reliability effectively combining and performance safety, reliability and performance in commercial and industrial applications

Motorised and automatic transfer enclosed switchess

FUSERBLOC Fuse combination switches for industrial fuses up to 1250 A

Versa II SLR Lubricator

Climas y Proyectos Leyco, S.A. de C.V.

Electric Actuated Ball Valves 150 lb Flanged Stainless Steel, Full Port 1/2 to 4 inch Pipe Sizes

INFRESCO-S-4kW X20034 Issue: 7

DIN Rail UPS Model: DIN-UPS Installation/Operation Manual

IMI vibration switch USER MANUAL INSTALLATION - OPERATION - MAINTENANCE

Mobrey 003. Ultrasonic Liquid Level Switch. Product Data Sheet February 2015 IP117, Rev DA. Self-contained liquid level alarm.

Diesel Engine Shutdown System

Linear actuator. Product features. Overview. Wide range of force outputs. Wide selection of column adapters. Wide selection of flanges

Call us now: (+44) Fuel Polishing And Filtration Equipment. Page 1

Product features & Overview. KA Linear actuators

WAFER STYLE KNIFE GATE VALVE

ECONOPLATE BV SERIES HOT WATER SERVICE PACKAGED HEAT EXCHANGERS WITH THERMAL STORES

Single foot switches PX and PA series

SECTION B1: MACHINE COMPONENTS

INSTALLATION INSTRUCTIONS FOR Owner's Copy FILTERED AND REGULATED POWER SUPPLY VOLTS DC INPUT: Hz.

SOLAR SMART. 12/24V 20Amp MPPT Solar Charge controller with Ethernet

ST - II Series POWER SUPPLIES USER INSTRUCTIONS

ATyS. 63 to 3200 A. Functions. Conformity to standards. General characteristics. Changeover switches. Functions

Product Instructions. Diverting Valve. Valve Cross Section. Features. Specifications. Operations

-2- Designed to automatically operate a diesel fire pump engine when the contacts of a remote water pressure switch close.

AMPTRON AMPTRON PRODUCT RANGE. ELECTRONICS (Pty) Ltd REG. NO: 79/02792/07. Cape Town

DIN Rail UPS DC UPS/Battery Detection System Model: BDS-DIN-UPS Installation/Operation Manual

MODE - Multiple Occupancy Distribution Equipment Selection guide for low voltage indoor distribution up to 500A

Key features. DESIGNS: - Conservator type - Hermetically sealed

855 Filtrate Pump, Close Coupled and Overhead Mounted Pumps

Advantage-D. Operating Instructions and Maintenance Manual. Central Vacuum Systems (Expandable/Modular Models) (Ver.

Size: 1/4 to 3. Material: 316 Stainless Steel, Carbon Steel,

Timer Relays - Fixed & Adjustable

Distribution Blocks & Bus-bar Solutions

Rosemount 8750WA Magnetic Flowmeter System For Water and Wastewater Industries

Simplex Jobsite Wired Basin Package Non-Sparking Stainless Rail Non-Sparking, Class I, Group D, Division 1, w/fiberglass Cover

Zero Leakage Isolation Damper

Brake Pack SB50W. Standard AC Motors A-143. Standard AC Motors Intro duction. Brake Pack. AC Speed Control Motors Inverter.

Operating Instructions Pedestrian Turnstile Type MPT 33

Product features & Overview. N1 - N4 A Rotary and part-turn actuators

General Description. Product Specification. Document Digital Temperature Interlock

WAFER STYLE KNIFE GATE VALVE

Electric Actuated Ball Valves 2-way Stainless Steel, Full Port 1/4 to 2 inch NPT

Fire control. Electromagnetic fire Door Retainers. Available Models

PYTHON 1500 SERIES CONTROL VALVES. Pneumatic and Electric Actuated

Electric Actuated Ball Valves 2-way Stainless Steel, Full Port 1/4 to 2 inch NPT

CAUTION CM-SE CM-S21 CM-S41

Application Engineering

Shutter Fire Damper Type FSD GFSD 4/1.1/B/1

EM 101 EM EM EM GENERAL INFORMATION. SPECIFICATIONS MATERIALS Wetted Materials - FLOW RANGE

Installation Instructions

Electromotoric Actuators

Neotecha NTB - NTC PFA lined ball valves

Page ATALOGUE. Web: Tel: Fax:

AccuPower AQU126B Installation Instructions

ATyS S - ATyS d S Remotely operated Transfer Switching Equipment from 40 to 125 A

Electric Actuated 3-Way Ball Valves T-Port, Stainless Steel, Full Port 1/4 to 2 inch NPT

Transcription:

Free Fall Fire Valve Range & Accessories 1

Contents Screwed Free Fall Fire Valves... 3 Flanged Free Fall Fire Valves... 6 Free Fall Valve Accessories... 8 Fitting Kits... 8 Mercury and Non-Mercury Switches... 9 MQR Manual Quick Release... 11 EMQR Electro-Manual Quick Release... 14 E-Mag & E-Mag2 Electromagnetic Quick Release (SQR type device)... 19 Fusible Links... 23 Thermal Link... 24 Fire Valve Control Panel... 26 2

Screwed Free Fall Fire Valves Suitable for installation in either horizontal or vertical pipe work. Designed to provide a 100% shut off when used as a fuel isolating valve. May also be used as a fuel dump valve, whereby the valve will open on actuation. Standard Free Fall Valve assembly comprises of a valve, lever and weight, together with a fitting kit. Standard valves are manufactured in cast iron to ASTM A126 Gr B. Suitable for use with fuel oils at pressures up to 14 bar. Valves with screwed connections have BSP parallel threads, whilst flanged valves are available with either BS 4504 PN 16 flange drillings or to ANSI 125. Available with carbon or stainless steel body and plug materials. Standard Fire Valves are supplied with a Lubricating Compound, which is a general purpose sealant, suitable for hydrocarbons, other Lubricating Compounds are available. May be actuated mechanically or electrically. Supplied with a Fire Valve Kit, available in sizes, Small (15 to 50mm NB valves), Medium (65 to 100mm NB valves) and Large (125 to 200mm NB valves). Kits contain Pulley Wheels, Stainless Steel Cable, Fusible Links, Warning Signs, Cable Connectors and Tension Springs, any of which may be purchased as individual products. Electrically actuated Fire Valve systems utilise a standard valve, lever and weight and use an E-MAG Electro-Magnetic Release System, allowing actuation by making or breaking an electrical circuit, usually 24V DC or 230V AC. The installation of a valve mounted Mercury Switch, Electro Mechanical Release or Wall Mounted Changeover Switch may provide remote signalling of the Fire Valve status, or allow direct switching of electrical equipment where applicable. Competitively priced with a full range of ancillaries. 3

Call us now: (+44) 01565 733137 Email Us: sales@felvalves.com

Call us now: (+44) 01565 733137 Email Us: sales@felvalves.com

Flanged Free Fall Fire Valves Suitable for installation in either horizontal or vertical pipe work. Designed to provide a 100% shut off when used as a fuel isolating valve. May also be used as a fuel dump valve, whereby the valve will open on actuation. Standard Free Fall Valve assembly comprises of a valve, lever and weight all finished in RAL 3000 Flame Red, together with a fitting kit. Standard valves are manufactured in ductile iron GGG40 with brass or stainless steel internals. Suitable for use with fuel oils and gases at pressures up to 14 bar. The double Viton O ring stem seals make the valve ideal for vacuum pump suction lines. Valve connections are flanged to BS 4504 PN 16. May be actuated mechanically or electrically. Supplied with a Fire Valve Kit, available in sizes, Small 15 to 50mm valves, Medium 65 to 100mm valves) and Large 125 to 200mm valves. Kits contain Pulley Wheels, Stainless Steel Cable, Fusible Links, Warning Signs, Cable Connectors and Tension Springs, any of which may be purchased as individual products. Electrically actuated Fire Valve systems utilise a standard valve, lever and weight and use an electrical Release System allowing actuation by making or breaking an electrical circuit. The installation of a valve mounted Mercury Switch, Electro Mechanical Release or Wall Mounted Changeover Switch may provide remote signalling of the Fire Valve status, or allow direct switching of electrical equipment where applicable. Competitively priced with a full range of ancillaries. 6

Free Fall Kit Components 20-070 1/4" BSP x 40mm Pulley Wheel 20-071 M12 Male x 40mm Pulley 20-074 1/4" BSP x 40mm Anchor 20-075 M12 Male x 40mm Anchor 20-077 1/4" BSP Backplate 20-078 M12 Backplate 20-080 9m 316 Stainless Steel Cable 20-081 30m 316 Stainless Steel Cable 20-082 150m 316 Stainless Steel Cable 20-101 Tension Spring 20-107 Caution Sign for stainless cable Mechanical Free Fall System Components Caution Soldered Fusible Links 20-090 71C 160F 20-091 92C 197F 20-092 104C 220F 20-093 127C 260F 20-094 143C 290F Mercury Changeover Switches 20-150 Single Phase 10 amp 20-151 Three Phase 10 amp Release Mechanisms 20-160 Manual Quick Release 20-161 ElectroManual Release Screwed Free Fall Fire Valves Flanged Free Fall Fire Valves 20-001 1/2" 20-012 2" 20-003 3/4" 20-014 2 1/2" 20-005 1" 20-016 3" 20-007 1 1/4" 20-017 4" 20-009 1 1/2" 20-018 5" 20-011 2" 20-019 6" 20-013 2 1/2" 20-020 8" Spare Free Fall Kits 20-060 'Small' For 1/2" to 2" Valves 20-061 'Medium' for 2 1/2" to 4" Valves 20-062 'Large' for 5" to 8" Valves Spare Valve Sealing Compound 20-050 '650' For Oil & Gas 20-051 '750' for High Temp Oil & gas Electro-Mechanical Free Fall System Components Battery Trickle Chargers 20-185 230V ac input/3.2a/hr 24V dc Output 20-186 230V ac Input/6.0a/hr 24V dc Output Electro Magnetic Valve Release Mechanisms 20-162 24V dc Emag 20-163 110V ac Emag 20-164 230V ac Emag 20-165 24V dc Emag2 c/w Volt Free Contacts 20-166 110V ac Emag2 c/w Volt Free Contacts 20-167 230V ac Emag2 c/w Volt Free Contacts Remote Alarms 20-195 Red 230V ac 150mm Bell 20-196 Red 24V dc 150mm Bell 20-265 230V ac Audio/Visual Alarm Electro-Thermal Fusible Links 20-170 71C 160F 20-171 84C 194F 20-172 96C 205F 20-173 121C 218F 20-174 167C 330F 20-175 184C 360F 20-176 228C 440F Mercury Changeover Switches 20-150 Single Phase 10 amp 20-151 Three Phase 10 amp Fire Valve Control Panels 20-180 230V ac Input/230V ac Output 20-181 230V ac Input/110V ac Output 20-182 24Vdc Input/24V dc Output 20-183 230V ac Input/Battery Backed 24V dc Output Screwed Free Fall Fire Valves Flanged Free Fall Fire Valves 20-001 1/2" 20-012 2" 20-003 3/4" 20-014 2 1/2" 20-005 1" 20-016 3" 20-007 1 1/4" 20-017 4" 20-009 1 1/2" 20-018 5" Spare Valve Sealing Compound 20-011 2" 20-019 6" 20-050 '650' For Oil & Gas 20-013 2 1/2" 20-020 8" 20-051 '750' for High Temp Oil & gas Push Buttons & Break Glass Call Points 20-155 230Vac/24Vdc Emergency Knock Off 20-156 230Vac/24Vdc Knock Off c/w Key Release 20-196 Red Break Glass Call Point 20-197 Yellow Break Glass Call Point 20-198 Green Break Glass Call Point 7

Free Fall Valve Accessories Fitting Kits Contents Individual Kit Components Product code Small Kit Contents 20-060 15mm to 50mm Valves Medium Kit Contents 20-061 65mm to 100mm Valves Large Kit Contents 20-062 125mm to 200mm Valves 40mm diam. ¼ BSP 20-070 2 4 8 Pulley Double Pulley 20-073 0 0 1 Arrangement ¼ BSP Galvanised 20-077 3 5 9 Backplate Brass Anchor, ¼ BSP 20-079 1 1 1 Thread 9m Stainless Cable 20-080 1 2 0 30m Stainless Cable 20-081 0 0 1 71C Fusible Link 20-090 1 2 3 Tension Spring 20-101 1 0 0 Cable Turnbuckle 20-102 0 1 1 Caution Sign 20-107 1 2 3 Cable Connectors 20-110 8 10 16 Small Kit, 20-060 for 15 to 50mm Valve Sizes Medium Kit, 20-061 for 65 to 100mm Valve Sizes Large Kit, 20-062 for 125 to 200mm Valve Sizes 8

Mercury and Non-Mercury Switches Valve mounted changeover switches provide position status via a robust volt free changeover switch, rated to 230V 10 amps, allowing direct switching of pumps or relays upon valve actuation or 0.75 amp rated nonmercury normally open switches. Single phase mercury switch assemblies house one single pole changeover switch, whilst three phase installations have three SPCO switches, housed within one enclosure. The SPCO switch is a steel encased mercury switch, potted within a dielectric resin and encapsulated within a sealed terminal enclosure, which in turn, is fixed within a grey ABS valve mounted housing. The switching action is generated by valve closure. As the valve lever travels from 45 degrees above the horizontal plane of the pipe to 45 degrees below the pipe, although both single and three phase versions can also be used with vertically mounted Free Fall Fire Valves. An alternative, NM non mercury switch assembly is also available, rated at 230V AC 0.25 amp, SPST configuration, and ideal for water industry applications or where the use of mercury as a switching media is not authorised. All Free Fall Fire Valves manufactured by FEL have predrilled levers to accept retrofitted mercury changeover switches. Single Phase Three Phase 9

Dimensions: 20-150/M Single Phase: 125 x 85 x 60mm Deep ABS enclosure. 20-151/M Three Phase: 150 x 100 x 60 Deep Open Position Fixing Dimensions: Centres: 2 No 6.5mm diameter holes 102mm Wide to suit Fire Valve lever drilling. Electrical Ratings: 20-150/M Single Phase: 230V ac 10 amp SPCO mercury 20-150/NM Single Phase: 230V ac 0.25 amp SPST non mercury 20-151/M Three Phase: 3 x 230V ac 10 amp SPCO switches 20-151/NM Three Phase: 3 x 230V ac 0.75 amp SPST switches Closed Position 10

MQR Manual Quick Release Product Code 20-160 Designed for use with fusible link operated free fall fire valve systems Provides manual release of fire valve system Can be used with electro-mechanical fire valve Systems 40mm red push button operation Integral shroud to prevent accidental operation Brass release spindle and 40mm pulley wheel assembly Wall or generator enclosure mounting Optional 24v DC volt free changeover switch Option Red/Green LED s for status indication Can be used in conjunction with E-Mag & E-Mag2 electro-magnetic release 11

MQR Enclosure Dimensions: 132 x 65 x 55mm Deep ABS Enclosure, With 40mm diameter red push button Fixing Dimensions: 2 x 4.2mm Diameter holes, Centres: 35mm wide x 95mm high 12

The Manual Quick Release (MQR) is designed for use with fusible link actuated fire valves. In operation, the MQR provides manual activation of the fire valve system. Pressing the red push button will release the fire valve cable tension, allowing the valve to close by gravity. The MQR is usually sited adjacent to an Exit doorway in a plant room or generator enclosure and is particulary useful for testing fire valve systems as well as providing manual fire valve closure in an event whereby an operator observes something of concern and does not want to wait for a fusible link to melt, triggering valve closure. The MQR can also be used in conjunction with a wall mounted FEL E-Mag or E-Mag2 electromagnetic fire valve release. This combination provides fire valve release options by fusible link, MQR manual operation and also electrically using an E-Mag via a fire alarm interface. 13

EMQR Electro-Manual Quick Release Product Code 20-161 Designed for use with fusible link actuated fire valves. Provides manual activation of the fire valve system by pressing the red push button. Automatically senses the release of tension on the stainless steel fire valve cable. Internal volt free change over switch changes status, de-energising the Load terminal energising the Alarm output terminal. Safety shroud included. When tension is applied to the stainless steel fire valve cable, this will upwardly extend the spring loaded, removable spindle housed within the EMQR. By doing this, the Load terminal is energised and the Green Load Circuit lamp is illuminated. Release of tension or pressing the red push button will contract or release the spring loaded spindle and the Red Alarm Circuit lamp is illuminated whilst turning off the Load lamp. 14

EMQR Enclosure EMQR Enclosure Dimensions: 125 x 175 x 100mm Deep ABS enclosure, side hinged for ease of access. With 40mm diameter red push button. Fixing Dimensions: Centres: 4 No. 4.2mm diameter holes 160mm wide x 110mm high Electrical rating: Internal changeover switches are rated 230V AC 6 amps For 230V AC Operation For 24V DC Operation Term No Designation Term No Designation 1 Incoming 230V AC Live 11 Incoming 24V DC +ve 2 230V AC Neutral 12 24V DC -ve 3 230V AC to Load 13 24V DC +ve to Load 4 230V AC to Alarm 14 24V DC +ve to Alarm 5 Do Not Use 15 Do Not Use 15

Schematic Arrangement Tension Spring Loaded Spindle Push Button The EMQR is designed for use with fusible link actuated fire valves. In operation, the EMQR provides manual activation of fire valve system by pressing the red push button, or, it can automatically detect when a fusible link has melted by sensing the release of tension on the stainless steel fire valve cable. In either event, an internal volt free changeover switches changes status, de-energising the Load terminal energizing the Alarm output terminal. When tension is applied to the stainless steel fire cable, this will upwardly extend the spring loaded removable spindle housed within the EMQR, by doing this, the Load terminal is energized and the green Load Circuit lamp is illuminated. Release of tension or pressing the red push button will contract or release the spring loaded spindle and the red Alarm Circuit lamp is illuminated whilst turning off the Load lamp. 16

Call us now: (+44) 01565 733137 Email Us: sales@felvalves.com `

Call us now: (+44) 01565 733137 Email Us: sales@felvalves.com

E-Mag & E-Mag2 Electromagnetic Quick Release (SQR type device) The E-Mag and E-Mag2 Electromagnetic quick release mechanisms are for use with electrically actuated fire valve systems. They provide instant release of Free Fall Fire Valves when de-energised, making them the ideal method for remote fire valve closure. The E-Mag is a standard electromagnet, which will de-magnetise on loss of power, the E- Mag2 version has inbuilt auxilliary volt free changeover contacts, which signal valve status. Both E-Mag and E-Mag2 may be installed as wall mounted or direct mounted. Wall mounted E-Mag or E-Mag2 installations can be designed to release a stainless steel fire valve cable, which can be used in the normal way with pulley wheels and fusible link, by using an interface which will isolate a fuel supply in the event of a Fire Alarm or other means of control input by de-energising the electromagnet. Similar to the way in which an automatic fire door closes in the event of a building fire alarm. However, the system still incorporates a fusible link, providing a mechanical means of fire valve shut off as well as electrical control. Direct mounting installations have the E-Mag or E-Mag2 sited directly above the fire valve and do not incorporate a fusible link in the system, but rely upon electrical control only. Both E-Mag & E-Mag2 version include a Push to test facility and have 40Kg electromagnetic holding power as standard. For 230V AC Operation For 24V DC Operation Term No Designation Term No Designation 1 Incoming 230V AC Live 11 Incoming 24V DC +ve 2 230V AC Neutral 12 24V DC -ve 3 230V AC to Load 13 24V DC +ve to Load 4 230V AC to Alarm 14 24V DC +ve to Alarm 5 Do Not Use 15 Do Not Use 19

Open Position Wall mounted E-Mag or E-Mag 2 Electromagnetic Release used with soldered fusible link for electrical control with mechanical fusible link local fire protection Closed Position 20

E-Mag Mounting Plate, 6mm thick mild steel, with 2 x11mm diam, fixing holes at 155mm centres. Mounting plate finished solver coat Spring loaded centre overcomes any residual magnetic force when the electromagnet is de-energised Electromagnetic Face E-Mag (Electromagnetic Release) Technical Details Product Code Voltage Power Consumption Holding force 20-162 24V DC ZVA 40Kg 20-163 110V AC ZVA 40Kg 20-164 230V Ac ZVA 40Kg 21

E-Mag2 Mounting Plate, 6mm thick mild steel, with 2 x11mm diam, fixing holes at 155mm centres. Mounting plate finished solver coat Spring loaded centre overcomes any residual magnetic force when the electromagnet is de-energised Electromagnetic Face The E-Mag2 Range of electromagnetic releases mechanisms have in builds volt free changeover contacts to indicate valve status. When the E-Mag2 is de-energised, an internal relay provides a common to normally open or normally closed. E-Mag2 (Electromagnetic Release) Technical Details Product Code Voltage Power Consumption Holding force 20-165 24V DC ZVA 40Kg 20-166 110V AC ZVA 40Kg 20-167 230V Ac ZVA 40Kg 22

Fusible Links A range of fusible links, manufactured from formed brass leaves, soldered using eutectic solder, each fitted with zinc plated steel S hooks for ease of installation within a fire valve system. The use of eutectic solder, as opposed to a ranged solder, gives rise to greater accuracy at the actual fuse temperature. FEL Valves fusible links are available in the following temperatures. Also available as a Heavy Duty Link, with 45Kg maximum weight strain rating. Customised versions also available. Fusible Links Product Code Fuse Temperature (C) Maximum Weight Strain 20-090 71C 13Kg 20-091 92C 13Kg 20-092 104C 13Kg 20-093 127C 13Kg 20-094 143C 13Kg Technical Specification: Standard Duty Links 18swg blanks 12.5mm wide 5mm dia hole. Overall length from 47mm. Static loading up to 30lb Heavy Duty Links 16swg blanks 21mm wide 6mm dia hole. Overall length 90mm. Static loading up to 45kg 23

Thermal Link Product Code 20-170 Product Overview Fuse Details Electro Thermal Link, contains a fuse which melts when excessive ambient temperature is detected breaking the power supply to safety valves. Electrical Rating: 10A, 230VAC Fuse melts at 72 0 C Enclosure: IP30 Single use non-resettable thermal fuse, suitable for use with standard single phase power supplies 250V (typical 230V). Approvals: VDE, SEV, UL Wiring Installation The unit should be fitted between 0.3 to 1.3m directly above the potential fire hazard with the slotted lid facing downloads. Can be suspended by metal conduit. The ventilation holes in the box must not be covered. Allow free unrestricted airflow through the enclosure. Overall Dimensions 24

Product Codes Electro-Thermal Links Product Code Fuse Temperature (C) Fuse Temperature (F) 20-170 71C 160F 20-171 84C 194F 20-172 96C 205F 20-173 121C 218F 20-174 167C 330F 20-175 184C 360F 20-176 228C 440F 25

Call us now: (+44) 01565 733137 Fire Valve Control Panel Email Us: sales@felvalves.com The FEL Fire Valve Control Panel is used to maintain power to an E-MAG or SQR type device Power Output is 24V DC, with 230V Input 24V DC Units are battery backed and designed to maintain power output in the event of mains failure whilst continuing to provide fire detection through electro-thermal links or normally closed emergency push buttons wired in series Battery backup time and battery size is calculated on the required load to maintain multiple E-Mag, Motorised Valves or SQR type devices BMS connectivity via volt free contacts Product Number: 20-180 230V AC input/output Fire Valve Control Panel 20-183 230V AC input and 24V DC Output Battery Backed 26

Call us now: (+44) 01565 733137 Email Us: sales@felvalves.com Panel Specification: Dimensions 500mm High x 400mm wide x 150mm deep Panel weight 14 Kg Fixing style Wall mounting Cable entry Bottom entry Supply 230V AC 6 amp Isolator Fascia mounted 2 pole 20 amp Internal PSU 230V AC to 24V DC, 3.5 amp, battery backed Batteries 2 x Yuasa 12V 3.1Ah in series Battery Power 1 Hour on mains failure Panel Operating Philosophy: Action Power ON MCB1 ON MCB2 ON Press 'Mute' Effect 230V Supply Healthy LED illuminates Internal PSU energised Control circuit and field supplies are energised 24VDC Supply Healthy LED illuminates Fire Valve Closed Red LED will illuminate Audible alarm will sound This will de-energise the audible alarm Sensing With sensing circuit not in alarm and a voltage on terminal 6 Circuit Press 'Reset' This will energise terminals 7 & 8 Status Switch Press 'Test' The fire valve, motorised valve or Emag will now be energised. If fitted this will energise R2 and illuminate Red fire valve closed LED This will provide a volt free output via terminals 11 &12 Fire Valve Closed' LED illuminates & Audible Alarm will sound Typical Wiring Diagram 27

Call us now: (+44) 01565 733137 Email Us: sales@felvalves.com Typical Terminal Designation: Terminal Designation: Terminal Number Voltage Designation 1 230V AC Incoming Live 2 230V AC Incoming Neutral 3 24V DC Spare 4 0V Spare 5 24V DC Sensing Circuit 24 DC 6 0V Sensing Circuit 0V 7 24DC Emag 24V DC 8 0V Emag ve 0V 9 24V DC Valve switch status 10 24V DC Valve switch status 11 Rated 230V Valve Closed Volt Free 12 Rated 230V Valve Closed Volt Free N/O 13 Rated 230V Mains Failure VF Com 14 Rated 230V Mains Failure VF NO 28

Call us now: (+44) 01565 733137 Email Us: sales@felvalves.com Did you know that we also supply the following? Float Switches Fill Point, Level Gauges, Controls Motorised Valves Pumps & Panels Fuel Polishers 29