ELECTRIC VEHICLE CHARGING FOR BUILDINGS

Similar documents
Burnaby Electric Vehicle (EV) Charging Infrastructure Technical Bulletin Requirements and Guidelines for EV Charging Bylaw

Bulletin Engineering Department 6911 No. 3 Road, Richmond, BC V6Y 2C1

CHAPTER V RESIDENTIAL WIRING

City of Walnut Creek Development Review Services 1666 N. Main Street, Walnut Creek, CA (925) phone (925) fax

Electric Vehicle Appendix Notes

EV Charging Station Submittal Requirements

Fee $20 Course: NEC Changes 1 This course is valid for these credentials: Credential Description Cred Code Credit Hours

MECKLENBURG COUNTY. Land Use and Environmental Service Agency Code Enforcement 2/8/12 ELECTRICAL CONSISTENCY MEETING. Code Consistency Questions

The following are specific provisions of 1910(a)(2) that could be seen in the LBM sector

Electric Vehicle Charging Station Article California Electrical code (CEC) General Requirements:

Permitting, Installation and Inspection Residential EV Chargers Be aware that there are different types of Electric Vehicle (EV) Chargers.

Expedited Permitting Process for Electric Vehicle Charging Stations

Schedule of Electrical Permit Fees. Contractor

SOLAR PV STANDARD PLAN - COMPREHENSIVE Central/String Inverter Systems for One and Two Family Dwellings

Photovoltaic Solar Plan Review

Solar PV Standard Electric Plan

Electric Vehicle Charging Station Article California Electrical code (CEC) General Requirements:

9/16/2010. Chapter , The McGraw-Hill Companies, Inc. TRANSMISSION SYSTEMS. 2010, The McGraw-Hill Companies, Inc.

COUNTY OF RIVERSIDE BUILDING AND SAFETY DEPARTMENT

Permit for Charging Equipment Installation Electric Vehicle Supply Equipment (EVSE)

Solar PV Standard Electrical Plan

Load Side PV Connections

DIVISION 311 MISCELLANEOUS ELECTRICAL RULES

Solar PV Standard Plan Simplified Microinverter and ACM Systems for One- and Two-Family Dwellings

Technical Support for Electric Vehicle Charging Requirements in the Building Code that are in effect January 1, 2018

Have You Been Grounded Lately

A Look at the 2017 NEC Significant Changes

90.2 Scope. The installation of electrical conductors, equipment and raceways for:

Chapter CALIFORNIA GREEN BUILDING STANDARDS CODE. Palo Alto Municipal Code

Circuit Concepts (Residential)

Solar PV Standard Plan Simplified Central/String Inverter Systems for One- and Two-Family Dwellings

Solar PV Standard Plan Simplified Central/String Inverter Systems for One- and Two-Family Dwellings

Solar PV Standard Plan Simplified Microinverter and ACM Systems for One- and Two-Family Dwellings

City of Perris Development Services Building & Safety

The Council of the City of Palo Alto does ORDAIN as follows:

Solar PV Standard Plan Simplified Microinverter and ACM Systems for One- and Two-Family Dwellings

2. DEFINITIONS. 2.3 APPROVED Acceptable to the authority enforcing the National Electric Code

Solar PV Standard Plan Simplified Microinverter and ACM Systems for Oneand Two-Family Dwellings

Requirements for Secondary Voltage Revenue Metering (750 V and less)

PV Installations 2015 Electrical Code & more. Presented by: Ted Olechna Director Codes and Standards Support

Electric Vehicle Charging System Guidelines for Residential Buildings

SECTION 1: Field Inspection Guide for Rooftop Photovoltaic (PV) Systems

Spring Test 10 due 05/11/2013

Volume 2 Charts, Formulas, and Other Useful Information

TABLE OF CONTENTS. About the Mike Holt Enterprises Team... xviii CHAPTER 1 ELECTRICAL THEORY... 1

Chapter 1 Electrical Theory...1

Metering and Service Installation:

2016 Photovoltaic Solar System Plan Review List

Arc Fault Circuit Interrupter (AFCI) FACT SHEET

Pretest Module 24 Three-phase Service Entrance

TRANSMISSION SYSTEMS

Corrections most seen on plan review October 18, 2017 David Rankin Seattle Department of Construction and Inspections

SINGLE PHASE WIRING SPECIFICATIONS

4 018 (See App B) m Revised wording and clarification of requirements when selecting conductors

RESIDENTIAL GUIDELINE FOR ELECTRICAL VEHICLE (EV) CHARGER INSTALLATION

Electrical Tech Note 106

ECET 211 Electric Machines & Controls Lecture 3-1 (Part 1 of 2) Motors, Transformers and Distribution Systems

Section 6 Electric Metering: Residential

THREE PHASE WIRING SPECIFICATIONS

TABLE OF CONTENTS CHAPTER 1 ELECTRICAL THEORY About This Textbook...xi. Passing Your Exam...xiv. How to Use the National Electrical Code...

Roof Top Solar Permit Document 1 Submittal Requirements Bulletin. Solar Photovoltaic Installations 10 kw or Less in One- and Two-Family Dwellings

MECKLENBURG COUNTY. Land Use and Environmental Service Agency Code Enforcement 9/14/11 ELECTRICAL CONSISTENCY MEETING. Code Consistency Questions

Proposed Zoning Bylaw Text Amendments Pertaining to Electric Vehicle Charging Infrastructure Requirements (Bylaw No. 4905,2018)

Chapter 8 Interior Wiring and Lighting

City of Manhattan Beach Community Development

Electrical Tech Note 105 Agricultural Engineering Department Michigan State University

ENGINEERING SPECIFICATION

2018 Consultant s Handbook Division 26 Electrical 2413 Switchboards

UNIT 1 ELECTRICIAN S MATH AND BASIC ELECTRICAL FORMULAS...1 Introduction...1. UNIT 2 ELECTRICAL CIRCUITS...49 Introduction...49

Fee Schedule for Whitehall Township

ELECTRICAL - GENERAL REQUIREMENTS SELF INSPECTION CHECKLIST

Chapter 2 Wiring and Protection Article 200 Use and Identification of Grounded Neutral Conductor Chapter 1 General...9

Technical Support for Electric Vehicle Charging Requirements in the Building Code that are in effect January 1, 2018

Technical Support for Electric Vehicle Charging Requirements in the Building Code that are in effect January 1, 2018

ECET Circuit Design Motor Loads. Branch Circuits. Article 210

SECTION PANELBOARDS

See Part 3 for the Introduction for Article 314

Applicant and Site Information Job Address: Permit #:

2014 NEC Analysis Part 2

Design Standards NEMA

TEMPORARY ELECTRIC WIRING FOR CARNIVALS, CONVENTIONS, EXHIBITIONS, FAIRS AND SIMILAR USES

10 Commercial, Industrial, Agricultural Services

FACT SHEET Standard: Electrical Safety

Data Bulletin. Wire Temperature Ratings and Terminations INTRODUCTION WHY ARE TEMPERATURE RATINGS IMPORTANT?

UNDERGROUND SERVICES - SECONDARY

CHAPTER 10 ELECTRICAL. Notes:

SECTION VII METERING INSTALLATIONS

City of Palo Alto (ID # 8028) City Council Staff Report

RESIDENTIAL SUBDIVISION SERVICE REQUIREMENTS SECTION VI RESIDENTIAL SUBDIVISION SERVICE REQUIREMENTS

Electrical Tech Note 111 Biosystems & Agricultural Engineering Department Michigan State University

Managing Electric Vehicle Supply Equipment (EVSE) Installations

SUPPLEMENTAL CORRECTION SHEET FOR SOLAR PHOTOVOLTAIC SYSTEMS - ELECTRICAL

Understanding National Electric Code (NEC) tap rules How do they apply to circuit breaker terminals?

AMENDMENT ELECTRIC SERVICE MANUAL 2014

Home Business Certificate Regulations

BUILDING PERMIT FEES BUILDING VALUATION DATA

TRANSMITTAL THE COUNCIL SEP THE MAYOR TRANSMITTED FOR YOUR CONSIDERATION. PLEASE SEE ATTACHED. ERIC GARCET Mayor.

CITY OF LANCASTER SPV TOOLKIT DOCUMENT #1

Parking and Loading. Page 1 of 7

COMMERCIAL QUICK REFERENCE

Transcription:

PLANNING & DEVELOPMENT SERVICES Office of the Chief Building Official BULLETIN 2015-004-BU/EL June 25, 2015 ELECTRIC VEHICLE CHARGING FOR BUILDINGS This bulletin provides clarification of requirements of Subsection 10.2.3. of Division B of the Vancouver Building By-Law (VBBL 2014) with respect to Electric Vehicle Charging for Building and Electrical Rooms. In addition to that, it is intended by this bulletin to provide explanation and clarification of application of the Canadian Electrical Code, Part 1 (CE Code) in respect of installation of the electrical equipment related to the VBBL requirements of Electric Vehicle Charging. VBBL DEFINED TERMS Row housing means a building of residential occupancy where no dwelling unit is located above another dwelling unit and there is no common interior or exterior means of egress. Laneway house means a detached dwelling unit constructed in the rear yard of a parcel on which is situate a one-family dwelling or one-family dwelling with secondary suite. One-family dwelling with secondary suite means a building containing only two dwelling units of which the secondary suite is smaller than the principal residence. Two-family dwelling with secondary suites means a building containing two self-contained dwelling units where each self-contained dwelling unit contains one secondary suite. Secondary suite means that area of a building that is intended to be a dwelling unit that is smaller than the principal residence in the same building. Lock-off unit means a smaller dwelling unit within a larger principal dwelling unit, which must have separate external access and shared internal access, and which can be locked off from the larger dwelling unit, but does not include a secondary suite. EXPLANATORY INFORMATION AND SIMPLIFIED SUMMARY ON VBBL SUBSECTION 10.3.2 REQUIREMENTS: Electric Vehicle Charging for Buildings Article 10.2.3.1. of Division B of the Vancouver Building By-law regulates the requirements of Electric Vehicle Charging for Buildings. This Article is divided into five Sentences which are delineated by numbers in brackets as follows: Sentence (1) requires the separate branch circuit rated not less than 40 A (@ 208 / 240V) must be provided to power supply to an outlet box installed in each storage garage or carport in one-family dwellings, two-family dwellings, one-family dwellings or two-family dwellings with secondary suites or lock-off units, and laneway houses. Each outlet box for the purpose of electric vehicle charging must be labelled in a conspicuous, legible, and permanent manner identifying it as an electric vehicle supply equipment outlet. City Hall, 453 est 12th Avenue, Vancouver, BC V5Y 1V4 tel: 3-1-1, Outside Vancouver: 604.873.7000, website: vancouver.ca

Bulletin 2015-004-BU/EL June 25, 2015 ELECTRIC VEHICLE CHARGING FOR BUILDINGS Page 2 OF 4 Notwithstanding Sentence (1), the intent of Sentence (2) is, in lieu of the separate branch circuit, installation of a raceway not less than 21 mm running and connecting from the dwelling unit panelboard to an electrical outlet box located in the storage garage or carport is permitted, if computing the dwelling unit load that includes the 40 A branch circuit load will result the total calculated load of this dwelling unit greater than 200 A. Sentence (3) requires that each one of 20 percent of all parking stalls used by owners or occupiers of dwelling units in a multi-family building or the multi-family component of a mixed use building that includes three or more dwelling units must be provided with a receptacle for the purpose of electric vehicle charging. Sentence (4) requires that each one of 10 percent of all parking stalls in a commercial building, or the commercial component of a mixed use building must be provided with a receptacle for the purpose of electric vehicle charging. Sentence (5) mandates that the separate branch circuit rated not less than 40 A (@ 208 / 240V) must be provided to power supply to the receptacle required by Sentences (3) and (4). Electrical Rooms Sentence 10.2.3.2.(1) requires that the electrical room in a multi-family building or the multi-family component of a mixed use building with three or more dwelling units must be designed to have sufficient space to accommodate future installation of electrical equipment related to the electric vehicle charging, for the remainder of residential parking stalls that have not been provided with branch circuits supplying power supply to receptacles for the electric vehicle charging. CE CODE DEFINITIONS AND RULE Branch circuit that portion of the wiring installation between the final overcurrent device protecting the circuit and the outlet(s). Outlet a point in the wiring installation at which current is taken to supply utilization equipment. Overcurrent device any device capable of automatically opening an electric circuit, under both predetermined overload and short-circuit conditions, either by fusing of metal or by electromechanical means. Panelboard an assembly of buses and connections, overcurrent devices and control apparatus with or without switches, or other equipment constructed for installation as a complete unit in a cabinet. Raceway any channel designed for holding wires, cables, or busbars, and, unless otherwise qualified in the Rules of this Code, the term includes conduit (rigid and flexible, metal and non-metallic), electrical metallic and non-metallic tubing, underfloor raceways, cellular floors, surface raceways, wireways, cable trays, busways, and auxiliary gutters. Electric vehicle charging systems Rule 86-000(1) This Section applies to the installation of the electrical conductors and equipment external to an electric vehicle that connect an electric vehicle to a source of electric current by conductive or inductive means, and to the installation of equipment and devices related to electric vehicle charging.

Bulletin 2015-004-BU/EL June 25, 2015 ELECTRIC VEHICLE CHARGING FOR BUILDINGS Page 3 OF 4 EXPLANATION AND CLARIFICATION OF APPLICATION OF THE CE CODE RELATED TO THE VBBL REQUIREMENTS OF SUBSECTION 10.3.2. FOR ELECTRIC VEHICLE CHARGING 1. hen calculating the minimum ampacity of consumer s service conductors from a supply service supplying two-family dwellings, one-family dwellings or two-family dwellings with secondary suites or lock-off units, the size of consumer s service conductors between the BC Hydro point of attachment and multi position meter base must be based on the calculated load obtained from CEC Rule 8-200(2). hen determining the main bus rating of the multi position meter base, the main bus must have the ampere rating sized in accordance with CEC Rule 8-200(2). 2. The minimum ampacity of service or feeder conductors from a main service supplying two or more dwelling units of, two-family dwellings, one-family dwellings or two-family dwellings with secondary suites or lock-off units must be based on CEC Rule 8-200(2), as applicable. 3. hen the secondary suite of a two-family dwelling building is not individually metered for electrical power consumption and it is provided with an additional combination panelboard supplied by panelboard of the principal dwelling unit, the minimum ampacity of feeder conductors from the principal dwelling unit supplying the secondary suite must be based on the calculated load obtained from CEC Rule 8-200(1). In this case, the minimum ampacity of consumer s service conductors from the multi position meter base to service box of the dwelling unit containing secondary suite, the minimum ampacity of service conductors supplying the two-family dwelling building, or service or feeder conductors from a main service supplying the two-family dwelling building or dwelling unit(s) with secondary suite must be sized in accordance with CEC Rule 8-200(2), as applicable. 4. hen calculating the minimum ampacity of consumer s service conductors from a supply service supplying laneway house and one-family dwelling or laneway house, secondary suit and one-family dwelling with secondary suite, the size of consumer s service conductors between the BC Hydro point of attachment and multi position meter base must be based on the calculated load obtained from CEC Rule 8-200(2). hen determining the main bus rating of the multi position meter base, the main bus must have the ampere rating sized in accordance with CEC Rule 8-200(2) (see attachment for a fillable load calculation form). 5. The minimum ampacity of service or feeder conductors from a main service supplying two or more dwelling units of, laneway house and one-family dwelling or laneway house, secondary suite and one-family dwelling with secondary suite, must be based on CEC Rule 8-200(2), as applicable (see attachment for a fillable load calculation form). 6. The consumer's service conductors between each subdivision of the multiple meter mounting device and each consumer's service box supplying loads in the laneway house, one-family dwelling, secondary suite or one-family dwelling with secondary suite (individually metered), or the feeder conductors from a main service supplying laneway house, one-family dwelling, secondary suite or one-family dwelling with secondary suite, must have the minimum ampacity based on the calculated load obtained from CEC Rule 8-200(1), as applicable. 7. Laneway house means a detached dwelling unit. The determination of areas for a laneway house must also include the sum of 100% of the area on the ground floor that includes the inside dimensions of the area used for enclosed parking, for the purpose of CEC Rule 8-110 and Rule 8-200. Also see Rule 26-722(a) for the requirements of branch circuits for dwelling units.

Bulletin 2015-004-BU/EL June 25, 2015 ELECTRIC VEHICLE CHARGING FOR BUILDINGS Page 4 OF 4 8. hen calculating any electric vehicle supply equipment loads for the purpose of Subsection 10.3.2. of the VBBL, each EVSE load supplied by a branch circuit with a 100% demand factor of a minimum of 40A must be used in the load calculation, for the purpose of CEC Rule 8-200, Rule 8-202 and Section 86. 9. Receptacles must not be connected to a branch circuit having overcurrent protection rated or set at more than the ampere rating of the receptacle. Receptacles having configurations in accordance with Diagrams 1 and 2 must be connected only to circuits having a nominal system voltage and ampere rating corresponding to the rating of the configurations. Refer to CEC Rules 14-600 and 26-700(2). hen a receptacle of CSA Configuration 6-50R, 14-50R or 15-50R as shown in Diagram 1 of the CE code is used for the purpose of electric vehicle charging, the receptacle must be connected to a 250 V or 125/250 V branch circuit rated at 50 A. Receptacles having configurations in accordance with Diagram 1 or 2 used for the purpose of electric vehicle charging must be connected only to branch circuits having the ratings corresponding to the ratings of the configurations. 10. The installation of electrical equipment related to electric vehicle charging systems and electric vehicle charging stations must meet the requirements of the CE Code and manufacturer s instruction. (Original signed by) (Original signed by). hite P. Ryan, M.Sc., P.Eng. MANAGER, TRADES INSPECTION CHIEF BUILDING OFFICIAL DEPUTY CITY ELECTRICIAN DIRECTOR, BUILDING CODE & POLICY Attachment

PLANNING & DEVELOPMENT SERVICES Office of the Chief Building Official One-Family Dwelling Permit EP- Laneway House Permit EP- Electrical Load Calculation for Laneway House and One-Family Dwelling or One-Family Dwelling with Secondary Suite. CEC Rule 8-200(2). Attachment to Bulletin 2015-004-BU/EL Part 1. One-Family Dwelling Address : LH Address: CEC Rule 8-200(2) (1)(a)(i) a basic load of 5000 for the first 90 m² of living area (see Rule 8-110); plus (1)(a)(ii) an additional 1000 for each 90 m² or portion thereof in excess of 90 m²; plus (1)(a)(iii) any electric space-heating loads (Section 62); plus (1)(a)(iii) any AC Rule 8-106(4) One-FD m² (If applicable) Excluding secondary suite, if SS is individually metered. S Suite Address: Secondary Suite m² (If applicable) Portion of One-FD, if SS is individually metered. Laneway House m² (Including floor area used for enclosed parking) (1)(a)(iv) single electric range: 6000 + 40%-exceeds 12 k; plus (1)(a)(v) electric tankless water heaters or water heaters for steamers, swimming pools, hot tubs, or spas. 100%; plus (1)(a)(vi) electric vehicle charging equipment loads. 100%; plus (1)(a)(vii) additional loads: electric range provided-25% X (>1500 ), or no electric range provided-100% of (>1500 ) up to 6000, + 25% X (>6000 ); or (1)(b) (i) 100 A, exclusive of basement, is 80 m² or more; or (ii) 60 A, exclusive of basement floor area, is less than 80 m². Total calculated demand loads (watts) Each Main Breaker, O/C. Type & size of consumer s service conductors. CEC Rule 8-200(2) 8-200(2)(a) excluding any electric space-heating & air-cond loads: 8-202(3)(a)(i)-100% of calculated load of unit with heaviest load; + (3)(a)(ii)-65% of next two units. 8-200(2)(a)(b). 8-202(3)(b)(c). electric space-heating loads Section 62, subject to Rule 8-106(4) and 100% air-conditioning loads subject to Rule 8-106(4). Total Calculated Load: Amps Cu/Al AG/kcmil Amps Cu/Al AG/kcmil Amps Demand Application Cu/Al AG/kcmil *Area in m² (1 square meter = 10.764 square feet) *Contractor to provide accurate m² as calculated per info from Building or Development permit, for the purpose of CEC Rule 8-110. *Check box below: Same day service reconnection planned? Yes No *If No, each disconnecting means must be terminated prior to inspection. *To book an inspection when service is ready for the connection to the BC Hydro, call 3-1-1, 604-873-7000, or the 24-hour line at 604-873-7059. * The service panelboard and branch circuits from a panelboard of 1FD or SS or 1FD with SS must not be located and connected to outlets or electrical equipment in the detached LH. CEC Rules 26-402(1) 26-722(a). Zoning & Development Bylaw No. 3575. 100% 1FD: The size of consumer s service conductors between the BC Hydro point 65% LH: of attachment and multi position meter base to be based on the calculated load 65% SS Individually metered : obtained from Subrule (1)(a) or (b) and 8-202(3)(a)(i) to (ii); plus Electric space-heating loads: 8-202(3)(b)&(c). The main bus and each subdivision of the multi position meter Air-conditioning loads: base must comply with Rule 8-200(2) & (1). atts. (/240V) Amps. I have verified that the information contained within this document is correct. Size & Type of Service Conductors: (AG/kcmil, Cu/Al) Quantity of meters: Electrical Contractor Name & Licence # Email Address Phone Number Date: / / FSR Name & Registration # Signature Y M D

Electrical Load Calculation for Laneway House and One-Family Dwelling or One-Family Dwelling with Secondary Suite. CEC Rule 8-200(2) Part 2. Please enter all information where applicable. Areas of the One-Family Dwelling. (1 sq. m. = 10.764 sq. ft.) Ground Floor: m² Upper Floor: m² Basement: m² Areas of the Laneway House. Laneway House: m² The determination of areas for a detached one-family dwelling of Laneway House must include the sum of 100% of the area used for enclosed parking for the purpose of CEC Rule 8-110 and Rule 8-200(2). Secondary Suite Area: m² Electrical Equipment Used in Load Calculation. Type & attage of Electric Space-Heating: Type: Air-Conditioning Load: Heat Pump: Electric Booster for Geothermal Heating: Electric Range: Second Electric Range: Separate Built-in Cooking Units: Electric Clothes Dryer: Electric Tankless ater Heater: Electric Hot ater Tank: Electric Steamer: Electric ater Heater (swimming pool, hot tub, spa): Electric Sauna: Electric Vehicle Charging Equipment Loads: Electric Furnace / Motor: Type & atts of Addition Loads ith Rating In Excess of 1500 : Type: Type & atts of Addition Loads ith Rating In Excess of 1500 : Type: Type & atts of Addition Loads ith Rating In Excess of 1500 : Type: