ATEX/IECEx RTD temperature probe

Similar documents
Push-in RTD Temperature Probe with Connecting Cable

Mineral-Insulated RTD Temperature Probe According to DIN EN 60751

JUMO dtrans p20. Process pressure transmitter. Type Brief description. Key features. Block diagram

Screw-in melt RTD temperature probes

JUMO Dtrans T100 Screw-in RTD Temperature Probe with/without Transmitter

Cable resistance thermometer Model TR40

JUMO dtrans p20. Process pressure transmitter. Brief description. Special features. Block diagram. Approvals/approval marks (see "Technical data")

Surface thermocouple Model TC50

Contact Dial Thermometer

Cable thermocouple Model TC40

Screw-in melt thermocouples

JUMO dtrans p20 DELTA

Contact dial thermometer

Panel-mounted Thermostats

Resistance thermometer Without thermowell Model TR10-H

Cable resistance thermometer Model TR40

Cable resistance thermometer Model TR40

Screw-in resistance thermometers. Connecting cable. Technical data. Data Sheet Page 1/5

Temperature. Innovative solutions for the highest requirements

Spring loaded resistance thermometer

Thermocouple Without thermowell Model TC10-H

Cable thermocouple Model TC40

* * Data sheet DA A (ATEX) Differential pressure measuring device for potentially explosive areas

Magnetic float switch For vertical installation Model FLS (models with Ex approval: 60, AL-ADF)

Ex Devices. Reliable products for potentially explosive areas according to EU Directive 94/9/EC

Pressure transmitter for elevated media temperatures

Measuring insert for resistance thermometer Model TR10-A

JUMO MIDAS Pressure transmitter

Thermocouple For additional thermowell Model TC10-B

JUMO heattherm-at and JUMO heattherm-dr

Terminal Boxes in Stainless Steel SLS**.T

ANKERSMID Temperature controller ATC 510/520/525 for wall-mounting. Application

JUMO dtrans p02. Pressure transmitter. General application. Approvals/marks of conformity. Data Sheet Page 1/6. II 1/2G Ex ia IIC T6 Ga/Gb

Linear Luminaire for Fluorescent Lamps Series ECOLUX METAL 6010/1

Screw-in RTD temperature probes with plug connector

Position Switches Series 8074/2

Room thermostats type series TRM

Miniature pressure switch, flameproof enclosure Ex d For the process industry Model PXA

JUMO DELOS SI. Precision pressure transmitter with switching contacts and display. Application. Brief description. Key features.

SPOOL VALVES solenoid air operated 1/4 to 1/2 tapped body and NAMUR for integrated pilot

DMP 331P DMP 331P. Industrial Pressure Transmitter. Pressure Ports And Process Connections With Flush Welded Stainless Steel Diaphragm

JUMO MIDAS S07 MA. OEM Pressure Transmitter - Maritime Approved. Applications. Brief description. Special features.

SITRANS T measuring instruments for temperature

JUMO ecoline Ci Inductive conductivity and temperature sensor for general water engineering

Load disconnect switch Series 8146/5-V11

Screw-in resistance thermometers with plug connector

ATEX HAZARDOUS-AREA RATED CONTAINER HEATERS AND CONTROLLER PRODUCT LAUNCH BOOK

Ex Devices. Reliable products for potentially explosive areas according to EU Directive 2014/34/EU

JUMO tecline CR-4P Conductive 4-Electrode Conductivity Sensor

Pressure Transmitter JUMO dtrans p30 Type

Position Switches Series 8060/2

Measuring insert For thermocouple with flameproof enclosure (TC10-L) Model TC10-K

JUMO ecoline Ci Inductive conductivity and temperature sensor for general water engineering

3/2, 5/2, 5/2 bistable and 5/3 way pneumatic solenoid valve

DMP 331P. Industrial Pressure Transmitter. Pressure Ports And Process Connections With Flush Welded Stainless Steel Diaphragm

PPT 802, Proximity Probe Transducer System

PXN12C DXN25C DXN37C MULTI-CONTACT CONNECTORS 10 A TECHNICAL FEATURES

ABG Cable Glands Installation Procedure

Magnetic Float Switches horizontal 1003-h

Capri ADE 6F - for Armoured Cable

JUMO MIDAS S06. OEM-Pressure Transmitter Low Pressure. Applications. Brief description. Customer benefits. Special features

JUMO heattherm Type Protection temperature limiter, as a panel-mounting thermostat Compensated for ambient temperature

Capacitive Sensors. Series 80 - PNP

Position Switches Series 8070/2

Level Measurement Continuous level measurement Guided wave radar transmitters

Level Measurement Continuous level measurement - Guided wave radar transmitters

Measuring insert for process resistance thermometer

Thermocouple For additional thermowell, flameproof enclosure (Ex d) Model TC10-L

Differential pressure transmitter PASCAL Ci4 Delta P

Rod thermostats (without immersion tube)

Linear fluorescent luminaire LED V-CG-S

* * Data sheet DA01 VUW (ATEX) Differential pressure measuring device Pressure levels PN250/PN400. Models for use in explosive areas

Relative pressure transmitter type 522 for shipbuilding

Resistance thermometer For sanitary applications, exchangeable sensor Model TR22-A

Mineral Insulated Resistance Thermometers (RTD)

A Higher Level of Performance. Data Sheet. Centurion. Guided Radar. CGR Series. For more information, please visit >

Thermocouples TE Measuring Insert. rigid Model TC 001 flexible Model TC 002. Electronic Temperature Measurement

INTERNATIONAL METAL ENGINEERING

V82 series - Redundant valve manifold systems - Compact 1oo2 Safety, 2oo2 Availability and 2oo3 Safety and Availability

HTSB system System overview

TRaC Global Limited, Unit 1, Pendle Place, Skelmersdale, West Lancashire, WN8 9PN, United Kingdom

Operating Instructions

Terminal Boxes Series 8125

Resistance Thermometers Model TR602, for Flat Surfaces Model TR603, for Pipe Surfaces

Resistance thermometer For additional thermowell, flameproof enclosure (Ex d) Model TR10-L

Relative and absolute pressure transmitter type 528

Product specification

Temperature. Innovative solutions for the most demanding standards

Load cells. Data sheet. Special features. Cable assignment (six wire configuration)

The safety you rely on.

JUMO PEKA Process Connection Adapter

Magnetic float switch For vertical installation Model FLS

Temperature sensor TE2

Linear Luminaire with LED Series EXLUX 6002/2 Version IIC

Assembly. Trunk IN + - S U, I U, I. Spur 1

Glass tube flowmeters Series 6000 Variable area flowmeter for liquids and gases

Versions. Version with K VS Version with K VS 2.0. Fig. 1: Type 3967 Solenoid Valve

Cable thermocouple Model TC40

Power (W) Tamb 40 o C LX1GAM4LB57 5,700 10, T3 T100 o C T4 T85 o C 13

Electronic Monitoring Systems

Transcription:

Page 1/8 ATEX/IECEx RTD temperature probe with connecting cable acc. to DIN EN 60751 For temperatures from -100 to +600 C As single, double, or triple RTD temperature probe In two-wire, three-wire, or four-wire circuit Shielded connecting cables (silicone, PTFE, metal braiding/glass fiber, PVC, PUR, FEP, RADOX, BETAflam ) Application-specific design types Brief description Due to their specific features, ATEX/IECEx RTD temperature probes with connecting cables are used in pharmaceutical and chemical plants, power plants, pipelines, on test rigs, in engine manufacturing, and at any measuring locations requiring flexibility and simple replacement. The good thermal transfer between the protection tube and temperature sensor enables short response times and excellent measuring accuracy. The special construction guarantees a long operating life. A Pt100 temperature sensor according to DIN EN 60751, class AA, A or B in a two-wire, threewire or four-wire circuit is used as a measuring insert as standard versions with Pt500, Pt1000, Ni1000, or NTC are also possible. Basic type 902821/80 Ex i and 902821/90 Ex e Basic type 902821/81 Ex i and 902821/91 Ex e Basic type 902821/82 Ex i and 902821/92 Ex e Approvals/approval marks (see "Technical data")

Page 2/8 Technical data Connection Connecting cable ends stripped bare or with the insulation stripped in part, available with ferrules (standard), with plug-in sleeves, or multi-pole plug connectors Connecting cable Silicone Ambient temperature -50 to +180 C PTFE Ambient temperature -190 to +260 C Metal braiding/ glass fiber Ambient temperature -50 to +350 C PUR Ambient temperature -30 to +105 C PVC Ambient temperature -5 to +80 C or -5 to +105 C FEP Ambient temperature -5 to +105 C RADOX Ambient temperature -40 to +120 C BETAflam Ambient temperature -40 to +120 C FPM Ambient temperature -50 to +180 C PEEK Ambient temperature -60 to +180 C Protection tube Stainless steel AISI 316, Ø 3 mm, Ø 4 mm, Ø 5 mm, Ø 6 mm, Ø 7 mm, Ø 8 mm, and Ø 9 mm or in the case of the mineral-insulated RTD temperature probe: stainless steel 1.4541, Ø 1.9 mm, Ø 3 mm, and Ø 6 mm Protection tube constant As the diameter of the temperature probe varies, the protection tube constant varies as follows: 3.0 mm = 220 K/W 3.3 mm = 180 K/W 4.0 mm = 110 K/W 5.0 mm = 80 K/W The protection tube constant describes how the temperature rises on the surface of the probe as work is performed and must be taken into account when dimensioning the intrinsically safe electrical circuit and selecting the temperature class. Process connection Thread, clamping socket (clamp), or JUMO PEKA with EHEDG certification Measuring insert Standard: Pt100 temperature sensor, DIN EN 60751, class AA (1/3 DIN B), A or B available in two-wire, three-wire, or four-wire circuit NTC upon request

Page 3/8 Approvals/approval marks Approval mark Testing agency Certificates/ Inspection basis Certification numbers II 1/2 G Ex ia IIC T1... T6 Ga/Gb Electrosuisse SEV 13 ATEX 0197 EN 60079-0:2012 + A11:2013 II 1/2 G Ex ib IIC T1... T6 Ga/Gb EN 60079-11:2012 EN 60079-26:2007 II 1/2 D Ex ia IIIC T60 C... T80 C Da/Db IP6X II 1/2 D Ex ib IIIC T60 C... T80 C Da/Db IP6X II 2 G Ex ia IIC T1... T6 Gb Electrosuisse SEV 13 ATEX 0197 EN 60079-0:2012 + A11:2013 II 2 G Ex ib IIC T1... T6 Gb EN 60079-11:2012 EN 60079-26:2007 II 2 D Ex ia IIIC T60 C... T80 C Db IP6X II 2 D Ex ib IIIC T60 C... T80 C Db IP6X II 1/2 G Ex ia IIC T1... T6 Ga/Gb Electrosuisse IECEx SEV 13.0010 IEC 60079-0:2011 II 1/2 G Ex ib IIC T1... T6 Ga/Gb IEC 60079-11:2011 IEC 60079-26:2006 II 1/2 D Ex ia IIIC T60 C... T80 C Da/Db IP6X II 1/2 D Ex ib IIIC T60 C... T80 C Da/Db IP6X II 2 G Ex ia IIC T1... T6 Gb Electrosuisse IECEx SEV 13.0010 IEC 60079-0:2011 II 2 G Ex ib IIC T1... T6 Gb IEC 60079-11:2011 IEC 60079-26:2006 II 2 D Ex ia IIIC T60 C... T80 C Db IP6X II 2 D Ex ib IIIC T60 C... T80 C Db IP6X II 1/2 G Ex e IIC T1... T6 Ga/Gb Electrosuisse SEV 05 ATEX 0137 EN 60079-0:2009 II 1/2 D Ex tb IIIC T60 C... T80 C IP65 Da/Db EN 60079-7:2007 EN 60079-26:2007 EN 60079-31:2009 II 2 G Ex e IIC T1... T6 Gb Electrosuisse SEV 05 ATEX 0137 EN 60079-0:2009 II 2 D Ex tb IIIC T60 C... T80 C IP65 Db EN 60079-7:2007 EN 60079-26:2007 EN 60079-31:2009 EHEDG For process connection 997 JUMO PEKA TUM MAK No. 02/2006 Document No. 8

Page 4/8 Dimensions rigid = 50 flexible EL 40 AL D Basic type 902821/80 Basic type 902821/81 Basic type 902821/82 Basic type 902821/90 Basic type 902821/91 Basic type 902821/92

Page 5/8 Order details (1) Basic type 902821/80 Ex i Screw-in RTD temperature probe 902821/81 Ex i Push-in RTD temperature probes 902821/82 Ex i Mineral-insulated RTD temperature probes (operating temperature in area of the sheath cable: - 50 to +600 C) D EL 40 AL (2) Operating temperature in C (connecting cable) x x x 317-60 to +180 C (PEEK) x x x 373-50 to +180 C (FPM) x x x 378-50 to +180 C (silicone) x x x 386-50 to +260 C (PTFE) x x x 402-50 to +400 C (metal braiding/glass fiber) x x x 478-40 to +120 C (RADOX ) x x x 484-40 to +120 C (BETAflam ) x x x 724-5 to +80 C (PVC) x x x 730-5 to +105 C (PVC) x x x 908 5 to 105 C (PUR) x x x 912 5 to 105 C (FEP) (3) Measuring insert x x x 1001 1 Pt100 in three-wire circuit x x x 1003 1 Pt100 in two-wire circuit x x x 1005 1 Pt1000 in two-wire circuit x x x 1011 1 Pt100 in four-wire circuit x x x 2001 2 Pt100 in three-wire circuit (protection tube diameter as of 6 mm with basic type 902821/82) x x x 2003 2 Pt100 in two-wire circuit x x x 2005 2 Pt1000 in two-wire circuit x x 2011 2 Pt100 in four-wire circuit x x 3028 3 Pt100 in 2 three-wire and 1 two-wire circuit (4) Tolerance class according to DIN EN 60751 x x x 1 Class B x x x 2 Class A x x x 3 Class AA (1/3 DIN B) (5) Protection tube diameter D in mm x 1.9 Ø 1.9 mm (sheath cable Ø 1.5 mm) x x x 3 Ø 3 mm x x 4 Ø 4 mm x x 5 Ø 5 mm x x x 6 Ø 6 mm x x 7 Ø 7 mm x x 8 Ø 8 mm x x 9 Ø 9 mm (6) Insertion length EL in mm (20 to 50000 mm)

Page 6/8 x x x... Specification in plain text (7) Process connection x x 000 None x 102 Screw connection G 1/4 x 104 Screw connection G 1/2 x 106 Screw connection G 1 x 114 Screw connection M10 1 x 115 Screw connection M10 1.5 x 121 Screw connection M14 1.5 x 163 Union nut G 3/8 x 164 Union nut G 1/2 x 165 Union nut G 3/4 x 254 Compression fitting G 1/2 x 611 Clamping socket (clamp) DN 10/20 DIN 32676 (AISI 316 L) x 613 Clamping socket (clamp) DN 25/40 (1 /1.5 ) DIN 32676 (AISI 316 L) x 616 Clamping socket (clamp) DN 50 (2 ) DIN 32676 (AISI 316 L) x 617 Clamping socket (clamp) 2.5 similar to DIN 32676 (AISI 316 L) x 997 JUMO PEKA with EHEDG certification (AISI 316 L) (suitable process connection adapters, data sheet 409711) (8) Process connection material x x x 00 None x x 24 CrNi 1.4404 (AISI 316 L) x x 26 CrNi 1.4571 (AISI 316 Ti) x x 31 CrNi 1.4435 (AISI 316 L) x x 46 CuZn (brass) (9) Connecting cable end x x x 03 Bare connection wires x x x 05 Part stripping of the insulation x x x 11 Ferrules (standard) x x x 13 Plug-in sleeve 6.3 x x x 23 Tab connector 6.3 x x x 42 Lemosa coupling x x x 56 Machine connector M12 1 x x x 57 Machine connector M8 1 (10) Connecting cable length AL in mm (20 to 100000 mm) x x x... Specification in plain text (11) Extra codes x x x 000 None x x x 058 SIL- and PL-compatible x x 310 Protection tube stepped down from Ø 6 mm to Ø 4 mm x x 315 Strain-relief spring x x 316 Strain-relief hose x x x 317 Shielded connecting cable (1) (2) (3) (4) (5) (6) (7) (8) (9) (10) (11) Order code - - - - - - - - - /,... a Order example 902821/80-317 - 1001-1 - 3-200 - 104-26 - 11-2500 / 315 a List extra codes in sequence, separated by commas.

Page 7/8 (1) Basic type 902821/90 Ex e Screw-in RTD temperature probe 902821/91 Ex e Push-in RTD temperature probes 902821/92 Ex e Mineral-insulated RTD temperature probes (operating temperature in area of the sheath cable: - 50 to +600 C) D EL 40 AL (2) Operating temperature in C (connecting cable) x x x 317-60 to +180 C (PEEK) x x x 373-50 to +180 C (FPM) x x x 378-50 to +180 C (silicone) x x x 386-50 to +260 C (PTFE) x x x 402-50 to +400 C (metal braiding/glass fiber) x x x 478-40 to +120 C (RADOX ) x x x 484-40 to +120 C (BETAflam ) x x x 724-5 to +80 C (PVC) x x x 730-5 to +105 C (PVC) x x x 908 5 to 105 C (PUR) x x x 912 5 to 105 C (FEP) (3) Measuring insert x x x 1001 1 Pt100 in three-wire circuit x x x 1003 1 Pt100 in two-wire circuit x x x 1005 1 Pt1000 in two-wire circuit x x x 1011 1 Pt100 in four-wire circuit x x x 2001 2 Pt100 in three-wire circuit (protection tube diameter as of 6 mm with basic type 902821/92) x x x 2003 2 Pt100 in two-wire circuit x x x 2005 2 Pt1000 in two-wire circuit x x 2011 2 Pt100 in four-wire circuit x x 3028 3 Pt100 in 2 three-wire and 1 two-wire circuit (4) Tolerance class according to DIN EN 60751 x x x 1 Class B x x x 2 Class A x x x 3 Class AA (1/3 DIN B) (5) Protection tube diameter D in mm x 1.9 Ø 1.9 mm (sheath cable Ø 1.5 mm) x x x 3 Ø 3 mm x x 4 Ø 4 mm x x 5 Ø 5 mm x x x 6 Ø 6 mm x x 7 Ø 7 mm x x 8 Ø 8 mm x x 9 Ø 9 mm (6) Insertion length EL in mm (20 to 50000 mm) x x x... Specification in plain text (7) Process connection

Page 8/8 x x 000 None x 102 Screw connection G 1/4 x 104 Screw connection G 1/2 x 106 Screw connection G 1 x 114 Screw connection M10 1 x 115 Screw connection M10 1.5 x 121 Screw connection M14 1.5 x 163 Union nut G 3/8 x 164 Union nut G 1/2 x 165 Union nut G 3/4 x 254 Compression fitting G 1/2 x 611 Clamping socket (clamp) DN 10/20 DIN 32676 (AISI 316 L) x 613 Clamping socket (clamp) DN 25/40 (1 /1.5 ) DIN 32676 (AISI 316 L) x 616 Clamping socket (clamp) DN 50 (2 ) DIN 32676 (AISI 316 L) x 617 Clamping socket (clamp) 2.5 similar to DIN 32676 (AISI 316 L) x 997 JUMO PEKA with EHEDG certification (AISI 316 L) (suitable process connection adapters, data sheet 409711) (8) Process connection material x x x 00 None x x 24 CrNi 1.4404 (AISI 316 L) x x 26 CrNi 1.4571 (AISI 316 Ti) x x 31 CrNi 1.4435 (AISI 316 L) x x 46 CuZn (brass) (9) Connecting cable end x x x 03 Bare connection wires x x x 05 Part stripping of the insulation x x x 11 Ferrules (standard) x x x 13 Plug-in sleeve 6.3 x x x 23 Tab connector 6.3 x x x 42 Lemosa coupling x x x 56 Machine connector M12 1 x x x 57 Machine connector M8 1 (10) Connecting cable length AL in mm (20 to 100000 mm) x x x... Specification in plain text (11) Extra codes x x x 000 None x x x 058 SIL- and PL-compatible x x 310 Protection tube stepped down from Ø 6 mm to Ø 4 mm x x 315 Strain-relief spring x x 316 Strain-relief hose x x x 317 Shielded connecting cable (1) (2) (3) (4) (5) (6) (7) (8) (9) (10) (11) Order code - - - - - - - - - /,... a Order example 902821/90-317 - 1001-1 - 3-200 - 104-26 - 11-2500 / 315 a List extra codes in sequence, separated by commas.