TURBINE FLOW METER SELECTION GUIDE

Similar documents
TURBINE FLOW METER Installation and Operation Guide

F-4600 INLINE ULTRASONIC FLOW METER Installation and Operation Guide

TURBINE FLOW METER Installation and Operation Guide

F-1500 SERIES INSERTION TURBINE FLOW METER

F-2700 SERIES INSERTION VORTEX FLOW METER

F-2700 SERIES INSERTION VORTEX FLOW METER

F-2600 SERIES INLINE VORTEX FLOW METER

TECHNICAL DOCUMENTATION FOR ONICON INSERTION FLOW METERS

F-1500 SERIES INSERTION TURBINE FLOW METER FEATURES Belcher Road South, Largo, FL USA Tel +1 (727) Fax +1 (727)

F-2600 SERIES INLINE VORTEX FLOW METER

F-5100 Insertion Thermal Mass Flow Meter Installation and Operation Guide

F-2500 SERIES VORTEX METER

Full Profile Insertion

TECHNICAL DOCUMENTATION FOR ONICON SYSTEM-1 BTU METERS

Low Profile Insertion Vortex

FB-3500 BI-DIRECTIONAL ELECTROMAGNETIC FLOW METER Installation and Operation Guide

F-3500 ELECTROMAGNETIC FLOW METER Installation and Operation Guide

TECHNICAL DOCUMENTATION FOR ONICON SYSTEM-2 BTU METERS

Hydro-Flow 2200 Fixed Insertion Vortex Flow Meter

Hydro-Flow Model 3100 Retractable Insertion Vortex Flowmeter Installation and Operation Manual

ONICON Insertion Turbine Flow Meters Single Turbine vs. Dual Turbine Selection Criteria

Hydro-Flow Model 2200 Installation and Operation Guide B

tekson TS Series Low Cost Ultrasonic Water Energy Flow Measurement

Model FVP General Specification. Flanged Vortex Plate. Product Features

TX 115/215 Hot-tap Insertion Turbine Instructions

Hydro-Flow Model 3100

Vortex Plate. Model VP General Specification. Product Features

Hot Tap Insertion Vortex

Hydro-Flow Model 2200 Fixed Insertion Vortex Flowmeter Installation and Operation Manual

P2050S-030, 1/2, Electronic Pressure Independent Valve Stainless Steel Ball and Stem, Female NPT Ends

Model 1100 Turbine Flow Meter

Electro-Magnetic Flowmeters Sensors MagMaster MFE

Sanitary Sensors. High Quality, Precision. Sanitary Sensors. THORNTON Leading Pure Water Analytics

Accutubes. Accuracy True double averaging design +1% of rate accuracy +0.1% repeatability Tested and certified by independent flow labs

8000 Series Liquid Flow Meter

SERIES TBS INSERTION TURBINE TBS-0XX TBS-1XX

Insertion Flow Meters. Municipal Market Customer Presentation

ABB Instrumentation. MagMaster MFE Series Electromagnetic Sensors. Specifications. MagMaster - bringing unsurpassed flowmetering performance

KDM ARMORED FLOW METER & SWITCH

A1 Commercial Grade Meters

8000 Series Liquid Flow Meters

F-5100 Inline Thermal Mass Flow Meter Installation and Operation Guide

Field IT Electro-Magnetic Flowmeters Sensors

ONICON Flow and Energy Measurement

FT-3100 ONICON. Inline Electromagnetic Flow Meter Installation and Operation Manual. Flow and Energy Measurement

flow measurement solutions RIM10 series rotor insertion flowmeters

Rosemount 8750WA Magnetic Flowmeter System For Water and Wastewater Industries

TX101/201 Insertion Turbine Instructions

Product Data Sheet. Flow Sensors. Insert Style Flow Sensors SDI Series DESCRIPTION HOT TAP SENSORS (OPTIONAL) APPLICATIONS FUNCTIONALITY

mass flowmeter for compressed air

G2 Industrial Grade Meters

mass flowmeter for compressed air

TX115/215 Hot-tap Insertion Turbine Instructions

DW PADDLE-BELLOWS FLOWMETER & SWITCH

BARTON 7400 Precision Gas Turbine Flow Meters

PSF50 Paddle flow switch

From. McCROMETER, INC WEST STETSON AVENUE HEMET, CA Phone (951) Toll Free (800) Fax (951)

BI-DIRECTIONAL INSERTION FLOW TRANSDUCER

Signet Conductivity/Resistivity Electrodes

Multivariable Vortex Flow Meter

DW PADDLE-BELLOWS FLOWMETER & SWITCH

Product Summary. Flow Meters. Hydraulic Diagnostic Products

SeaMetrics Flow Meters and Flow Computers

Technical Datasheet. HM U Series. Turbine Flow Meters. for lubricating liquids

M3500 Industrial Pressure Transmitter

FPI-X FULL PROFILE INSERTION ELECTROMAGNETIC FLOW METER MODEL 395X MAG METER SUBMITTAL

MEASURE TODAY. ENSURE TOMORROW. SpireMag Series T-MAG Electromagnetic BTU Meter

Sanitary Turbine Flow Meter - TA3 Installation, Operating & Maintenance Manual

DUST ALERT BinMaster Price Book binmaster.com Subject to change without notice 1

PFM6 Digital Portable Hydraulic Tester

Technical Datasheet. HM R Series. Turbine Flow Meters. with Female Inch Threads

TX100/200-SERIES INSERTION TURBINE INSTRUCTIONS TX101/201 TX115/215 ISO 9001:2008 CERTIFIED COMPANY

Multivariable Vortex Flow Meter

The readings you need, right where you need them. AX Series Vortex Meters

RIM20 Rotor Insertion Flowmeter

Simple Set COMMERCIAL. Pressure Independent Control Valves 2 Way 1/2-2 02/16/18 COMMERCIAL

The full WeatherTRAK Flow3 Installation and Maintenance Manual is available online at

Installation and Operation Instructions DLP Series

G2 SERIES INDUSTRIAL GRADE METERS

The readings you need, right where you need them. AX Series Vortex Meters

Transmitting Transducer. Gas/Air Velocity Range:

See Water Pressure Reducing Valves Catalog (PHBRWPRV) for more detailed information about the products in this section.

See Water Pressure Reducing Valves Catalog (PHBRWPRV) for more detailed information about the products in this section.

Electric Actuated Ball Valves 3-Piece Stainless Steel, Full Port 1/4 to 3 inch NPT

SECTION ELECTRONIC ACTUATED PRESSURE REDUCING VALVES AND ACCESSORIES

F-3100 SERIES Inline Electromagnetic Flow Meter Installation & Basic Operation Guide

EMP1 OPERATING & INSTALLATION INSTRUCTIONS

MS Application. Features. Proportional Valve Actuator General Instructions

FLS F6.60 MAGMETER FLOW SENSOR INSERTION FLOW SENSORS APPLICATIONS MAIN FEATURES

M Series. Feature rich flow meter and switch with in-line. flow

DW PADDLE-BELLOWS FLOWMETER & SWITCH

2-Way & 3-Way Non Spring Return Characterized Ball Valves

DARTMOUTH COLLEGE DESIGN January 3, 2012 & CONSTRUCTION GUIDELINES

Pressure transmitter for general industrial purposes Type MBS 3000 and MBS 3050

F-2600 & F-2700 Series Vortex Flow Meter Installation and Operation Guide

INSERTION flowmeter with paddle wheel, ELEMENT design

Webster Instruments. (A division of Webtec Products) Product Overview. The Webster Range of Hydraulic Test Equipment

KEL. Heavy Duty Differential Pressure Flowmeters

UNIVERSAL Flow Meters

RUN ACCUM. TOTAL STOP BAT LOW HIGH

Transcription:

TURBINE FLOW METER SELECTION GUIDE I. MODEL NUMBERING SYSTEM Format: F(B)-XX YY SERIES F-11 Single Turbine, Insertion Type (1¼" and larger pipes) F-12 Dual Turbine Insertion Type (2½" and larger pipes) FB-12 Bi-Directional, Insertion Type (2½" and larger pipes) F-13 Inline Turbine Meter ¾ and 1 See Single vs. Dual turbine selection criteria Example: F-1210 = Dual turbine, analog output OUTPUT SIGNAL 00 Frequency Output (15 V pulse) For connection to Onicon display or BTU meter only. Signal is too fast for most building control systems (0-300 hz). 10 Analog Output (non-isolated) Provides both 4-20 ma and 0-10 V outputs. Most commonly used output type. (3-wire connection) 11 Isolated Analog Output Provides both 4-20 ma and 0-10 V outputs. Signal ground is isolated from power supply and pipe ground. (4-wire connection) 20 Divided Output (dry contact) Provides an isolated binary/digital output. Signal is divided to limit the maximum frequency. For rate/totalization. 30 Scaled Output (dry contact) Provides an isolated binary/digital output scaled to provide one pulse per desired unit volume (i.e.: 1 pulse = 10 gal.). Ideal for totalization applications. II. INSTALLATION HARDWARE Purchase of installation kit with the flow meter (insertion type) is strongly recommended to prevent installation problems. Installation hardware kits are listed immediately after insertion type flow meters. III. CALIBRATION DATA ONICON flow meters are custom calibrated for each application. Pipe size, material, flow range, etc. is required for all meters. Use order form and fax or e-mail directly to ONICON Incorporated. Order forms are provided in the product catalog and can be downloaded from ONICON s website (you may also use your own spreadsheet, etc. to submit calibration data). Contact ONICON for assistance with calibration data questions. IV. PERIPHERAL DEVICES AVAILABLE Display Modules: See D-1200 Series Display Modules BTU Meters: See System-10, System-2 and System-30 Series BTU Meters (different order forms for these) V. APPLICATIONS ASSISTANCE Contact ONICON or your local sales representative for applications questions. 0266-1 3-7-05 www.onicon.com sales@onicon.com

F-1100 SINGLE TURBINE INSERTION FLOW METER Made in the USA DESCRIPTION ONICON insertion turbine flow meters are suitable for measuring electrically conductive water-based liquids. The F-1100 model provides a high-resolution frequency output for connection to an ONICON Display or BTU Meter. APPLICATIONS Chilled water, hot water, condenser water, and water/glycol/brine for HVAC Process water and water mixtures Domestic water GENERAL SPECIFICATIONS ACCURACY ± 0.5% OF READING at calibrated velocity ± 1% OF READING from 3 to 30 ft/s (10:1 range) ± 2% OF READING from 0.4 to 20 ft/s (50:1 range) SENSING METHOD Electronic impedance sensing (non-magnetic and non-photoelectric) PIPE SIZE RANGE 1¼" through 72" nominal SUPPLY VOLTAGE 24±4 V AC/DC at 30 ma LIQUID TEMPERATURE RANGE Standard: 180 F continuous, 200 F peak High Temp: 280 F continuous, 300 F peak Meters operating above 250 F require 316 stainless steel construction option AMBIENT TEMPERATURE RANGE -5 to 160 F (-20 to 70 C) OPERATING PRESSURE 400 PSI maximum PRESSURE DROP Less than 1 PSI at 20 ft/s in 1½" pipe, decreasing in larger pipes and lower velocities OUTPUT SIGNAL PROVIDED: 0-15 V peak pulse, typically less than 300 Hz (continued on back) CALIBRATION Every ONICON flow meter is wet-calibrated in our flow laboratory against primary volumetric standards directly traceable to NIST. Certification of calibration is included with every meter. FEATURES Unmatched Price vs. Performance - Custom calibrated, highly accurate instrumentation at very competitive prices. Excellent Long-term Reliability - Patented electronic sensing is resistant to scale and particulate matter. Low mass turbines with engineered jewel bearing systems provide a mechanical system that virtually does not wear. Industry Leading Two-year "No-fault" Warranty - Reduces start-up costs with extended coverage to include accidental installation damage (miswiring, etc.). Certain exclusions apply; see our complete warranty statement for details. Simplified Hot Tap Insertion Design - Standard on every insertion flow meter. Allows for insertion and removal by hand without system shutdown. OPERATING RANGE FOR COMMON PIPE SIZES 0.17 TO 20 ft/s ± 2% accuracy begins at 0.4 ft/s Pipe Size (Inches) Flow Rate (GPM) 1¼ 0.8-95 1½ 1-130 2 2-210 2½ 2.5-230 3 4-460 4 8-800 6 15-1800 8 26-3100 10 42-4900 12 60-7050 14 72-8600 16 98-11,400 18 120-14,600 20 150-18,100 24 230-26,500 30 360-41,900 36 510-60,900 www.onicon.com E-mail: sales@onicon.com 2103 / 0212PA 12-28-00

F-1100 SPECIFICATIONS cont. MATERIAL Wetted metal components Standard: Electroless nickel plated brass Optional: 316 stainless steel ELECTRONICS ENCLOSURE Standard: Weathertight aluminum enclosure Optional: Submersible enclosure ELECTRICAL CONNECTIONS 3-wire for frequency output Standard: 10' of cable with ½" NPT conduit connection Optional: Indoor DIN connector with 10' of plenum rated cable F-1100 Wiring Information WIRE COLOR CODE (+) 24 V AC/DC supply voltage, 30 ma ( ) Common ground (Common with pipe ground) (+) Frequency output signal: 0-15 V peak pulse NOTES positive negative Signal for ONICON Display or BTU meter F-1100 Wiring Diagram ALSO AVAILABLE ONICON Display or BTU Meter + 24 V FREQUENCY INPUT GROUND SEL GPM RST Note: Black wire is common with the pipe ground (typically earth ground). 463798 SYSTEM-1 BTU METER Display Modules BTU Measurement Systems Typical Meter Installation (New construction or scheduled shutdown) Acceptable to install in vertical pipe Position meter anywhere in upper 180 for horizontal pipe Optional output signal(s) to control system Onicon Display or BTU Meter CLEARANCE REQUI FOR INSTALLATION Connect factory wires to field wires in appropriate junction box. ONICON INCORPORATED 1500 North Belcher Road Clearwater, FL 33765 Tel (727) 447-6140 Fax (727) 442-5699 www.onicon.com sales@onicon.com 2103 / 0212B ½" FNPT conduit connection Insertion depth gage provided with each meter Minimum Hole Size = 1" Must be centered Detail of hot tap adapter with turbine assembly withdrawn Standard Installation Kit for Steel Pipe 1" Full port ball valve 1" Close nipple 1" Branch outlet FLOW 1¼" for hot tap Typically 30" - 36" depending on pipe size and height of valve assembly. Note: Installation kits vary based on pipe material and application. For installations in pressurized (live) systems, use "Hot tap" 1¼ inch installation kit and drill hole using a 1 inch wet tap drill. 12-28-00

F-1110 SINGLE TURBINE INSERTION FLOW METER ANALOG OUTPUT Made in the USA DESCRIPTION ONICON insertion turbine flow meters are suitable for measuring electrically conductive water-based liquids. The F-1110 model provides non-isolated 4-20 ma and 0-10 V analog output signals that are linear with the flow rate. APPLICATIONS Chilled water, hot water, condenser water, and water/glycol/brine for HVAC Process water and water mixtures Domestic water GENERAL SPECIFICATIONS ACCURACY ± 0.5% OF READING at calibrated velocity ± 1% OF READING from 3 to 30 ft/s (10:1 range) ± 2% OF READING from 0.4 to 20 ft/s (50:1 range) SENSING METHOD Electronic impedance sensing (non-magnetic and non-photoelectric) PIPE SIZE RANGE 1¼" through 72" nominal SUPPLY VOLTAGE 24±4 V AC/DC at 50 ma LIQUID TEMPERATURE RANGE Standard: 180 F continuous, 200 F peak High Temp: 280 F continuous, 300 F peak Meters operating above 250 F require 316 stainless steel construction option AMBIENT TEMPERATURE RANGE -5 to 160 F (-20 to 70 C) OPERATING PRESSURE 400 PSI maximum PRESSURE DROP Less than 1 PSI at 20 ft/s in 1½" pipe, decreasing in larger pipes and lower velocities OUTPUT SIGNALS PROVIDED: ANALOG OUTPUTS (NON-ISOLATED) Voltage output: 0-10 V (0-5 V available) Current output: 4-20 ma 0-15 V peak pulse, typically less than 300 Hz CALIBRATION Every ONICON flow meter is wet-calibrated in our flow laboratory against primary volumetric standards directly traceable to NIST. Certification of calibration is included with every meter. FEATURES Unmatched Price vs. Performance - Custom calibrated, highly accurate instrumentation at very competitive prices. Excellent Long-term Reliability - Patented electronic sensing is resistant to scale and particulate matter. Low mass turbines with engineered jewel bearing systems provide a mechanical system that virtually does not wear. Industry Leading Two-year "No-fault" Warranty - Reduces start-up costs with extended coverage to include accidental installation damage (miswiring, etc). Certain exclusions apply; see our complete warranty statement for details. Simplified Hot Tap Insertion Design - Standard on every insertion flow meter. Allows for insertion and removal by hand without system shutdown. OPERATING RANGE FOR COMMON PIPE SIZES 0.17 TO 20 ft/s ± 2% accuracy begins at 0.4 ft/s Pipe Size (Inches) Flow Rate (GPM) 1¼ 0.8-95 1½ 1-130 2 2-210 2½ 2.5-230 3 4-460 4 8-800 6 15-1800 8 26-3100 10 42-4900 12 60-7050 14 72-8600 16 98-11,400 18 120-14,600 20 150-18,100 24 230-26,500 30 360-41,900 36 510-60,900 (continued on back) www.onicon.com E-mail: sales@onicon.com 2103 / 0213PA 12-28-00

F-1110 SPECIFICATIONS cont. MATERIAL Wetted metal components Standard: Electroless nickel plated brass Optional: 316 stainless steel ELECTRONICS ENCLOSURE Standard: Weathertight aluminum enclosure Optional: Submersible enclosure ELECTRICAL CONNECTIONS 3-wire minimum for 4-20 ma or 0-10 V output Second analog output and/or frequency output requires additional wires Standard: 10' of cable with ½" NPT conduit connection Optional: Indoor DIN connector with 10' of plenum rated cable F-1110 Wiring Information WIRE COLOR CODE BLUE BROWN (+) 24 V AC/DC supply voltage, 50 ma ( ) Common ground (Common with pipe ground) (+) Frequency output signal: 0-15 V peak pulse (+) Analog signal: 4-20 ma (Non-isolated) (+) Analog signal: 0-10 V (Non-isolated) NOTES positive negative & analog input ground Required when meter is connected to local display or BTU meter Both signals may be used independently ALSO AVAILABLE F-1110 Wiring Diagram Flow Meter into Control System (No Display or BTU Meter) Power Source + 24 V SEL GPM RST COM 463798 Control System BLUE SIGNAL GROUND SYSTEM-1 BROWN OR ANALOG SIGNAL INPUT BTU METER Display Modules BTU Measurement Systems NOTE: 1. Black wire is common with the pipe ground (typically earth ground). 2. Frequency output required for ONICON display module or BTU meter, refer to wiring diagram for peripheral device. Typical Meter Installation (New construction or scheduled shutdown) Acceptable to install in vertical pipe Position meter anywhere in upper 180 for horizontal pipe To control system Onicon Display or BTU Meter (Optional) CLEARANCE REQUI FOR INSTALLATION Connect factory wires to field wires in appropriate junction box. ONICON INCORPORATED 1500 North Belcher Road Clearwater, FL 33765 Tel (727) 447-6140 Fax (727) 442-5699 www.onicon.com sales@onicon.com 2103 / 0213B ½" FNPT conduit connection Insertion depth gage provided with each meter Minimum Hole Size = 1" Must be centered Detail of hot tap adapter with turbine assembly withdrawn Standard Installation Kit for Steel Pipe 1" Full port ball valve 1" Close nipple 1" Branch outlet FLOW 1¼" for hot tap Typically 30" - 36" depending on pipe size and height of valve assembly. Note: Installation kits vary based on pipe material and application. For installations in pressurized (live) systems, use "Hot tap" 1¼ inch installation kit and drill hole using a 1 inch wet tap drill. 12-28-00

F-1200 DUAL TURBINE INSERTION FLOW METER Made in the USA DESCRIPTION ONICON insertion turbine flow meters are suitable for measuring electrically conductive water-based liquids. The F-1200 model provides a high-resolution frequency output for connection to an ONICON Display or BTU Meter. APPLICATIONS Chilled water, hot water, condenser water, and water/glycol/brine for HVAC Process water and water mixtures Domestic water GENERAL SPECIFICATIONS ACCURACY ± 0.5% OF READING at calibrated velocity ± 1% OF READING from 3 to 30 ft/s (10:1 range) ± 2% OF READING from 0.4 to 20 ft/s (50:1 range) SENSING METHOD Electronic impedance sensing (non-magnetic and non-photoelectric) PIPE SIZE RANGE 2½" through 72" nominal SUPPLY VOLTAGE 24±4 V AC/DC at 30 ma LIQUID TEMPERATURE RANGE Standard: 180 F continuous, 200 F peak High Temp: 280 F continuous, 300 F peak Meters operating above 250 F require 316 stainless steel construction option AMBIENT TEMPERATURE RANGE -5 to 160 F (-20 to 70 C) OPERATING PRESSURE 400 PSI maximum PRESSURE DROP Less than 1 PSI at 20 ft/s in 2½" pipe, decreasing in larger pipes and lower velocities OUTPUT SIGNAL PROVIDED: 0-15 V peak pulse, typically less than 300 Hz (continued on back) CALIBRATION Every ONICON flow meter is wet-calibrated in our flow laboratory against primary volumetric standards directly traceable to NIST. Certification of calibration is included with every meter. FEATURES Unmatched Price vs. Performance - individually calibrated, "Percentage of Reading" accurate instrumentation at very competitive prices. Excellent Long-term Reliability - patented electronic sensing is resistant to scale and particulate matter. Low mass turbines with engineered jewel bearing systems provide a mechanical system that virtually does not wear. Industry Leading 2-year "No-fault" Warranty - Reduces start-up costs with extended coverage to include accidental installation damage (miswiring, etc.). Certain exclusions apply; see our complete warranty statement for details. Installation Flexibility - Patented dual turbine models deliver outstanding accuracy in short pipe runs. Simplified Hot Tap Insertion Design - Standard on every insertion flow meter. Allows for insertion and removal by hand without system shutdown. OPERATING RANGE FOR COMMON PIPE SIZES 0.17 TO 20 ft/s ± 2% accuracy begins at 0.4 ft/s Pipe Size (Inches) Flow Rate (GPM) 2½ 2.5-230 3 4-460 4 8-800 6 15-1800 8 26-3100 10 42-4900 12 60-7050 14 72-8600 16 98-11,400 18 120-14,600 20 150-18,100 24 230-26,500 30 360-41,900 36 510-60,900 www.onicon.com E-mail: sales@onicon.com 2104 / 0217PA 12-28-00

F-1200 SPECIFICATIONS cont. MATERIAL Wetted metal components Standard: Electroless nickel plated brass Optional: 316 stainless steel ELECTRONICS ENCLOSURE Standard: Weathertight aluminum enclosure Optional: Submersible enclosure ELECTRICAL CONNECTIONS 3-wire minimum for frequency output Standard: 10' of cable with ½" NPT conduit connection Optional: Indoor DIN connector with 10' of plenum rated cable ALSO AVAILABLE F-1200 Wiring Information WIRE COLOR CODE (+) 24 V AC/DC supply voltage, 30 ma ( ) Common ground (Common with pipe ground) (+) Frequency output signal: 0-15 V peak pulse DIAGNOSTIC SIGNALS ORANGE Bottom turbine frequency WHITE Top turbine frequency F-1200 Wiring Diagram NOTES positive negative Signal for ONICON Display or BTU meter These signals are for diagnostic purposes - connect to local display or BTU Meter ONICON Display or BTU Meter SEL GPM RST 463798 SYSTEM-1 BTU METER WHITE ORANGE + 24 V FREQUENCY INPUT GROUND TOP TURBINE BOTTOM TURBINE Display Modules BTU Measurement Systems NOTE: Black wire is common with the pipe ground (typically earth ground). Typical Meter Installation (New construction or scheduled shutdown) Acceptable to install in vertical pipe Position meter anywhere in upper 180 for horizontal pipe Optional output signal(s) to control system Onicon Display or BTU Meter CLEARANCE REQUI FOR INSTALLATION Connect factory wires to field wires in appropriate junction box. ONICON INCORPORATED 1500 North Belcher Road Clearwater, FL 33765 Tel (727) 447-6140 Fax (727) 442-5699 www.onicon.com sales@onicon.com 2104 / 0217B ½" FNPT conduit connection Insertion depth gage provided with each meter Minimum Hole Size = 1" Must be centered Detail of hot tap adapter with turbine assembly withdrawn Standard Installation Kit for Steel Pipe 1" Full port ball valve 1" Close nipple 1" Branch outlet FLOW 1¼" for hot tap Typically 30" - 36" depending on pipe size and height of valve assembly. Note: Installation kits vary based on pipe material and application. For installations in pressurized (live) systems, use "Hot tap" 1¼ inch installation kit and drill hole using a 1 inch wet tap drill. 12-28-00

F-1210 DUAL TURBINE INSERTION FLOW METER ANALOG OUTPUT Made in the USA DESCRIPTION ONICON insertion turbine flow meters are suitable for measuring electrically conductive water-based liquids. The F-1210 model provides non-isolated 4-20 ma and 0-10 V analog output signals that are linear with the flow rate. APPLICATIONS Chilled water, hot water, condenser water, and water/glycol/brine for HVAC Process water and water mixtures Domestic water GENERAL SPECIFICATIONS ACCURACY ± 0.5% OF READING at calibrated velocity ± 1% OF READING from 3 to 30 ft/s (10:1 range) ± 2% OF READING from 0.4 to 20 ft/s (50:1 range) SENSING METHOD Electronic impedance sensing (non-magnetic and non-photoelectric) PIPE SIZE RANGE 2½" through 72" nominal SUPPLY VOLTAGE 24±4 V AC/DC at 50 ma LIQUID TEMPERATURE RANGE Standard: 180 F continuous, 200 F peak High Temp: 280 F continuous, 300 F peak Meters operating above 250 F require 316 stainless steel construction option AMBIENT TEMPERATURE RANGE -5 to 160 F (-20 to 70 C) OPERATING PRESSURE 400 PSI maximum PRESSURE DROP Less than 1 PSI at 20 ft/s in 2½" pipe, decreasing in larger pipes and lower velocities OUTPUT SIGNALS PROVIDED: ANALOG OUTPUTS (NON-ISOLATED) Voltage output: 0-10 V (0-5 V available) Current output: 4-20 ma 0-15 V peak pulse, typically less than 300 Hz (continued on back) CALIBRATION Every ONICON flow meter is wet-calibrated in our flow laboratory against primary volumetric standards directly traceable to NIST. Certification of calibration is included with every meter. FEATURES Unmatched Price vs. Performance - Custom calibrated, highly accurate instrumentation at very competitive prices. Excellent Long-term Reliability - Patented electronic sensing is resistant to scale and particulate matter. Low mass turbines with engineered jewel bearing systems provide a mechanical system that virtually does not wear. Industry Leading Two-year "No-fault" Warranty - Reduces start-up costs with extended coverage to include accidental installation damage (miswiring, etc.). Certain exclusions apply; see our complete warranty statement for details. Installation Flexibility - Patented dual turbine models deliver outstanding accuracy in short pipe runs. Simplified Hot Tap Insertion Design - Standard on every insertion flow meter. Allows for insertion and removal by hand without system shutdown. OPERATING RANGE FOR COMMON PIPE SIZES 0.17 TO 20 ft/s ± 2% accuracy begins at 0.4 ft/s Pipe Size (Inches) Flow Rate (GPM) 2½ 2.5-230 3 4-460 4 8-800 6 15-1800 8 26-3100 10 42-4900 12 60-7050 14 72-8600 16 98-11,400 18 120-14,600 20 150-18,100 24 230-26,500 30 360-41,900 36 510-60,900 www.onicon.com E-mail: sales@onicon.com 2104 / 0218PA-1 10-22-02

F-1210 SPECIFICATIONS cont. MATERIAL Wetted metal components Standard: Electroless nickel plated brass Optional: 316 stainless steel ELECTRONICS ENCLOSURE Standard: Weathertight aluminum enclosure Optional: Submersible enclosure ELECTRICAL CONNECTIONS 3-wire minimum for 4-20 ma or 0-10 V output Second analog output and/or frequency output requires additional wires Standard: 10' of cable with ½" NPT conduit connection Optional: Indoor DIN connector with 10' of plenum rated cable ALSO AVAILABLE F-1210 Wiring Information WIRE COLOR CODE BLUE BROWN (+) 24 V AC/DC supply voltage, 50 ma ( ) Common ground (Common with pipe ground) (+) Frequency output signal: 0-15 V peak pulse (+) Analog signal: 4-20 ma (non-isolated) (+) Analog signal: 0-10 V (non-isolated) DIAGNOSTIC SIGNALS ORANGE Bottom turbine frequency WHITE Top turbine frequency NOTES positive negative & analog input ground Required when meter is connected to local display or BTU meter Both signals may be used independently These signals are for diagnostic purposes - connect to local display or BTU Meter F-1210 Wiring Diagram Flow Meter into Control System (No Display or BTU Meter) Power Source SEL GPM RST + 24 V 463798 COM Control System SYSTEM-1 BTU METER BLUE BROWN OR SIGNAL GROUND ANALOG SIGNAL INPUT Display Modules BTU Measurement Systems NOTE: 1. Black wire is common with the pipe ground (typically earth ground). 2. Frequency output required for ONICON display module or BTU meter, refer to wiring diagram for peripheral device. Typical Meter Installation (New construction or scheduled shutdown) Acceptable to install in vertical pipe Position meter anywhere in upper 180 for horizontal pipe To control system Onicon Display or BTU Meter (Optional) CLEARANCE REQUI FOR INSTALLATION Connect factory wires to field wires in appropriate junction box. ONICON INCORPORATED 1500 North Belcher Road Clearwater, FL 33765 Tel (727) 447-6140 Fax (727) 442-5699 www.onicon.com sales@onicon.com ½" FNPT conduit connection Insertion depth gage provided with each meter Minimum Hole Size = 1" Must be centered Detail of hot tap adapter with turbine assembly withdrawn Standard Installation Kit for Steel Pipe 1" Full port ball valve 1" Close nipple 1" Branch outlet FLOW 1¼" for hot tap Typically 30" - 36" depending on pipe size and height of valve assembly. 2104 / 0218B-1 Note: Installation kits vary based on pipe material and application. For installations in pressurized (live) systems, use "Hot tap" 1¼ inch installation kit and drill hole using a 1 inch wet tap drill. 10-22-02

INLINE FLOW METER MODEL F-1300 TURBINE DESCRIPTION ONICON inline turbine flow meters are suitable for measuring electrically conductive water-based liquids. The F-1300 model provides a high-resolution frequency output for connection to an ONICON Display or BTU Meter. CALIBRATION Every ONICON flow meter is wet-calibrated in our flow laboratory against primary volumetric standards directly traceable to NIST. Certification of calibration is included with every meter. FEATURES Made in the USA Unmatched Price vs. Performance - Custom calibrated, highly accurate instrumentation at very competitive prices. Excellent Long-term Reliability - Patented electronic sensing is resistant to scale and particulate matter. Low mass turbines with engineered jewel bearing systems provide a mechanical system that virtually does not wear. Industry Leading Two-year "No-fault" Warranty - Reduces start-up costs with extended coverage to include accidental installation damage (miswiring, etc.). Certain exclusions apply; see our complete warranty statement for details. GENERAL SPECIFICATIONS ACCURACY ± 0.5% OF READING at calibrated velocity ± 2% OF READING from 0.8 to 38 GPM (50:1 range) SENSING METHOD Electronic impedance sensing (non-magnetic and non-photoelectric) PROCESS CONNECTIONS Threaded or sweat union fittings ¾" or 1" SUPPLY VOLTAGE 24±4 V AC/DC at 30 ma LIQUID TEMPERATURE RANGE Standard: 180 F continuous, 200 F peak High Temp: 280 F continuous, 300 F peak AMBIENT TEMPERATURE RANGE -5 to 160 F (-20 to 70 C) OPERATING PRESSURE 400 PSI maximum PRESSURE DROP 3 PSI at maximum flow rate OUTPUT SIGNAL PROVIDED: 0-15 V peak pulse, typically less than 300 Hz MATERIAL Brass housing and stem Sapphire bearings and tungsten carbide shaft ELECTRONICS ENCLOSURE Weathertight aluminum enclosure ELECTRICAL CONNECTIONS 3-wire for frequency output Standard: 10' of cable with ½" NPT conduit connection Optional: Indoor DIN connector with 10' of plenum rated cable APPLICATIONS Chilled water, hot water, condenser water, and water/glycol/brine for HVAC Process water and water mixtures Domestic water 2106 / 0227PA www.onicon.com E-mail: sales@onicon.com 12-28-00

Also Available F-1300 Wiring Information WIRE COLOR CODE NOTES SEL GPM RST (+) 24 V AC/DC supply voltage, 30 ma positive 463798 ( ) Common ground (Common with pipe ground) negative Display Modules SYSTEM-1 BTU METER BTU Measurement Systems (+) Frequency output signal: 0-15 V peak pulse Signal for ONICON Display or BTU meter F-1300 Wiring Diagram ONICON Display or BTU Meter + 24 V FREQUENCY INPUT GROUND Note: Black wire is common with the pipe ground (typically earth ground). Inline Flow Meter Dimensions L1 Sweat Threaded L1 H 9" L1 10¼" 5 3 /8" L2 8 5 /8" 3¼" L3 3¼" 8" H 8" H L3 L2 MAX 2" WIDTH 2" L3 L2 Typical Meter Installation (New construction or scheduled shutdown) Optional output signal(s) to control system Onicon Display or BTU Meter Connect factory wires to field wires in appropriate junction box. Flush piping system thoroughly before installing meter Acceptable to install in vertical pipe Position meter anywhere in upper 180 for horizontal pipe FLOW DIRECTION Y Strainer Upstream of Flow Meter ½" FNPT conduit connection ONICON INCORPORATED 1500 North Belcher Road Clearwater, FL 33765 Tel (727) 447-6140 Fax (727) 442-5699 www.onicon.com sales@onicon.com Isolation valve 5 Diameters Downstream 20 Diameters Upstream FLOW DIRECTION Isolation valve Bypass valve remains closed during normal operation. 2106 / 0227B-2 12-15-04

INLINE FLOW METER MODEL F-1310 TURBINE ANALOG OUTPUT DESCRIPTION ONICON inline turbine flow meters are suitable for measuring electrically conductive water-based liquids. The F-1310 model provides non-isolated 4-20 ma and 0-10 V analog output signals that are linear with the flow rate. CALIBRATION Every ONICON flow meter is wet-calibrated in our flow laboratory against primary volumetric standards directly traceable to NIST. Certification of calibration is included with every meter. FEATURES Made in the USA Unmatched Price vs. Performance - Custom calibrated, highly accurate instrumentation at very competitive prices. Excellent Long-term Reliability - Patented electronic sensing is resistant to scale and particulate matter. Low mass turbines with engineered jewel bearing systems provide a mechanical system that virtually does not wear. Industry Leading Two-year "No-fault" Warranty - Reduces start-up costs with extended coverage to include accidental installation damage (miswiring, etc.). Certain exclusions apply; see our complete warranty statement for details. GENERAL SPECIFICATIONS ACCURACY ± 0.5% OF READING at calibrated velocity ± 2% OF READING from 0.8 to 38 GPM (50:1 range) SENSING METHOD Electronic impedance sensing (non-magnetic and non-photoelectric) PROCESS CONNECTIONS Threaded or sweat union fittings 3/4" or 1" SUPPLY VOLTAGE 24±4 V AC/DC at 50 ma LIQUID TEMPERATURE RANGE Standard: 180 F continuous, 200 F peak High Temp: 280 F continuous, 300 F peak AMBIENT TEMPERATURE RANGE -5 to 160 F (-20 to 70 C) OPERATING PRESSURE 400 PSI maximum PRESSURE DROP 3 PSI at maximum flow rate OUTPUT SIGNALS PROVIDED: ANALOG OUTPUTS (NON-ISOLATED) Voltage output: 0-10 V (0-5 V available) Current output: 4-20 ma 0-15 V peak pulse, typically less than 300 Hz MATERIAL Brass housing and stem Sapphire bearings and tungsten carbide shaft ELECTRONICS ENCLOSURE Weathertight aluminum enclosure ELECTRICAL CONNECTIONS 3-wire minimum for 4-20mA or 0-10V output Standard: 10' of cable with ½" NPT conduit connection Optional: Indoor DIN connector with 10' of plenum rated cable APPLICATIONS Chilled water, hot water, condenser water, and water/glycol/brine for HVAC Process water and water mixtures Domestic water www.onicon.com E-mail: sales@onicon.com 2106 / 0228PA-1 5-29-02

Also Available F-1310 Wiring Information SEL GPM RST Display Modules 463798 SYSTEM-1 BTU METER BTU Measurement Systems F-1310 Wiring Diagram Flow Meter into Control System (No Display or BTU Meter) BLUE BROWN OR Power Source + 24 V COM Control System SIGNAL GROUND ANALOG SIGNAL INPUT WIRE COLOR CODE (+) 24 V AC/DC supply voltage, 50 ma BLUE BROWN ( ) Common ground (Common with pipe ground) (+) Frequency output signal: 0-15 V peak pulse (+) Analog signal: 4-20 ma (Non-isolated) (+) Analog signal: 0-10 V (Non-isolated) NOTES positive negative & analog input ground Required when meter is connected to local display or BTU meter Both signals may be used independently NOTE: 1. Black wire is common with the pipe ground (typically earth ground). 2. Frequency output required for ONICON display module or BTU meter, refer to wiring diagram for peripheral device. Inline Flow Meter Dimensions L1 Sweat Threaded L1 H 9" L1 10¼" 5 3 /8" L2 8 5 /8" 3¼" L3 3¼" 8" H 8" H L3 L2 MAX 2" WIDTH 2" L3 L2 Typical Meter Installation (New construction or scheduled shutdown) Output signal(s) to control system Onicon Display or BTU Meter (optional) Connect factory wires to field wires in appropriate junction box. Flush piping system thoroughly before installing meter Acceptable to install in vertical pipe Position meter anywhere in upper 180 for horizontal pipe FLOW DIRECTION Y Strainer Upstream of Flow Meter ½" FNPT conduit connection ONICON INCORPORATED 1500 North Belcher Road Clearwater, FL 33765 Tel (727) 447-6140 Fax (727) 442-5699 www.onicon.com sales@onicon.com Isolation valve 5 Diameters Downstream 20 Diameters Upstream FLOW DIRECTION Isolation valve Bypass valve remains closed during normal operation. 2106 / 0228B-2 3-8-05