BZ-150. Installation Instructions. Power Pack SPECIFICATIONS

Similar documents
Installation Instructions

Installation Instructions

Installation Instructions

Installation Instructions

Installation Instructions

Installation Instructions

Installation Instructions

Installation Instructions

USER MANUAL 12 OUTLET 120/240V X-PLUG LIGHT CONTROLLER (FUEL SX12) APTX0120

SAVE THESE INSTRUCTIONS

SAVE THESE INSTRUCTIONS

Operations Manual. Zero Speed Switch Sensor Model ZS09P

INSTALLATION INSTRUCTIONS DEGR7700 DELAYED EGRESS ALL IN ONE DEVICE

model ps600 Address all communications and shipments to: FEDERAL SIGNAL CORPORATION

ZoneZ Lite Quick Start Guide

Generator Start Control Module

AquiTron. AT-PIR-SOV Water Shut-Off System INSTALLATION INSTRUCTIONS

2016 Lighting Catalog

Irrigation Components International, Inc.

2904 Power Supply Installation Instructions I-EA00041

USERS GUIDE LO-21U LOCKOUT RELAY

PD404-AN V analog control 4 Channel x 500 W Dimmer & Switch Packs ANALOG 0-10 V. Serial Number

SAVE THESE INSTRUCTIONS

Generator Start Control Module

FM200 FLOW/NO-FLOW MONITOR INSTALLATION AND TECHNICAL MANUAL 120 VAC MODEL 6/1/2017

Generator Start Control Module

Aura Interior Wiring Manual (5-Wire and BACnet)

Transfer Switch TS-50. Owner s Manual

Emergency Bypass / Shunt Relays (UL924)

HYGRODYNAMICS DIGITAL DEW POINT MONITOR PC BOARD MODEL 6392N & 6392N2 TABLE OF CONTENTS

GLM SERIES CONTROL Users Manual Rev:

GENERATOR START CONTROL MODULE

Installation/Owner s Manual 1601 / 1602

Transfer Switch GPTS 30

INSTALLATION & OWNER'S MANUAL

CIVACON GROUND VERIFICATION RACK MONITOR SYSTEM and ASSOCIATED EQUIPMENT

Installation Instructions for Eaton Surge Protective

GENERATOR START CONTROL MODULE

User Manual. T6 Tachometer. Online: Telephone: P.O. Box St. Petersburg, Florida 33736

INSTRUCTION MANUAL. A battery protector for vehicles with equipment that Is operated with the engine not running. MODEL# INPUT: 12 Volts D.C.

INSTRUCTION BOOK FOR. Tensioned Advantage Deluxe Electrol

Setup and Programming Manual

INSTRUCTION BOOK FOR. Cosmopolitan Electrol For Sizes Up To 9' x 12'

Installation/Owner s Manual 1603

Model LA 4100 Time Delay OFF Controller

The Da-Lite Difference.

AUTO-EC-3-E-PLC Electric Filter Backwash Controller Operation & Maintenance Manual

ACSI MODEL 1440 POWER SUPPLY INSTALLATION INSTRUCTIONS

Data Bulletin. Ground-Censor Ground-Fault Protection System Type GC Class 931

ICM 326HN/327HN Line Voltage Head Pressure Control Installation, Operation & Application Guide

Installation and Operation Instructions 10/04/13

ANZI Transfer Switch and Generator Wiring Installation Addendum

Motion Sensing Coach Light

ACC Series Power Conditioner OPERATION & INSTALLATION MANUAL

INSTALLATION/OPERATING INSTRUCTIONS TSC

IMPORTANT SAFEGUARDS READ THIS MANUAL AND FOLLOW ALL SAFETY INSTRUCTIONS THOROUGHLY BEFORE OPERATING THE EMIU INVERTER SYSTEM SAVE THESE INSTRUCTIONS

Electronically Commutated Motors

Industry Compliance The cabinet and modules are Listed to applicable UL Standards and requirements by Underwriters Laboratories Inc.

OPERATION MANUAL Variable Speed Pump Controller Dated: 06/04/2013 Pump Down Application. Document No.: LMSII_V100_OM Page 1 of 8 Model-V100 LMS II

The Da-Lite Difference.

Installation/Owner s Manual 1601 / 1602

LED Auxiliary Devices

Auto-Trol Limited 1660 SW 196th Avenue * Aloha, OR 97003

These devices meet the requirements of OSHA 29 CFR (b)(1)(ii) and OSHA 29 CFR (a) (2)(ii)(G). Airpax LEL series

IMPORTANT SAFEGUARDS READ THIS MANUAL AND FOLLOW ALL SAFETY INSTRUCTIONS THOROUGHLY BEFORE OPERATING THE LMIU INVERTER SYSTEM SAVE THESE INSTRUCTIONS

Instruction Book for. ContouR ElECtRol

INDUSTRIAL CHARGER AUTOMATIC BATTERY CHARGER SERIES 150 KUSSMAUL ELECTRONICS CO., INC. MODEL # XX YEAR WARRANTY INSTRUCTION MANUAL

MODEL 422 Submersible Pump Controller

MODEL A96 SERIES. 130Vdc Switchmode Utility Rectifier / Battery Charger. Used with LaMarche Power Cage ECN/DATE

BE SURE POWER IS DISCONNECTED PRIOR TO INSALLATION! FOLLOW NATIONAL, STATE, AND LOCAL CODES! READ THESE INSTRUCTIONS ENTIRELY BEFORE INSTALLATION!

MaxLite LED UTILITY WRAP FIXTURES

Owner s Manual POWER SOLUTION. AUTOMATIC CIRCUIT SWITCH. JTB Manufacturing, Inc. Part No Manufacture Date Year: 2013 Month:

Flight Systems. Replacement for KASSEC DESCRIPTION

Model LA 4400 Time Delay OFF Controller

ELECTRICAL SYSTEM RP-7

The POWER. In PRESENTATION PRODUCTS. Instruction Book for COSMOPOLITAN ELECTROL For Sizes Up To 9'x12' DA-LITE SCREEN COMPANY, INC.

ITS-50R TRANSFER SWITCH OWNER S MANUAL

CENTRIFEEDER ELECTRONICS

Congratulations. You ve just purchased the most advanced flasher available on the market today. This

SYMBOL LEGEND DANGER WARNING NOTE THIS INDICATES DANGER TO THE LIFE AND HEALTH OF THE USER IS APPROPRIATE PRECAUTIONS ARE NOT TAKEN

0.5 s to 30 h (30 s, 3 min, 30 min, 3 h, 30 h)

LED Emergency Drivers

Model LA 4300 Time Delay OFF Controller

slp-ul-m KIT INSERT Instructions A. B. C. E. F. G.

24HR 30A SPST TM SW. Features. Long Description

PBA Series Prelube Controls

Dimensions 12/800N 12/1200N D. DC to AC Power Inverters. OWNERS MANUAL for Models: OWNERS MANUAL April ISO 9001:2000 Certified Company

INSTRUCTIONS FOR THE RELIANCE Fast/Tran TM ARL0909 & ARL0909R

MODEL 233P/111P/233P-1.5

Web Volume Control Model WV220

STYLE 3491 Severe Duty Electric Mining Water Cannon INSTALLATION, AND OPERATING INSTRUCTIONS

User Manual. 1. Introduction

DORMA Automatics, Inc. 924 Sherwood Drive Lake Bluff, Illinois U.S.A. Toll Free: Fax:

115 VAC Control Boxes for

SB 2000 PUSH TO SEARCH NEXT STAG E. Aerotech, Inc. FORM: QM 1320

DUALBRITE Motion Sensing Coach Light

Florham Park, NJ USA Call (ASCO) for sales or service

User's Manual. Earth Ground Resistance Tester. Model Introduction

SPECIFICATIONS ATTENTION OPERATION DESCRIPTION

DIN Rail UPS Model: DIN-UPS Installation/Operation Manual

Transcription:

SPECIFICATIS Voltages...120/. 50/60Hz Load Requirements Ballast... 20amp @120/ Incandescent... 20amp @ Motor... 1HP @120/240VAC Output...225mA @ (with relay connected) Input Control... 12- Hold... 12- Hold OFF... 12- Manual (momentary switch required)... 12- Operating Temperature... 32-104 F (0-40 C) Installation Instructions

DESCRIPTI The power pack is the foundation for any low voltage lighting control system. The supplies low voltage power to occupancy sensors and other control devices, switching line voltage in response to signals from control devices. The power pack is attached to existing junction boxes or mounted into fixture wiring trays. Low voltage wiring should use at least 22-gauge wire. High voltage connections should use at least 14-gauge. Always check local building codes. After initial wiring is complete, check wiring diagrams to verify the power pack is wired correctly. Improper wiring can cause damage to the power pack, lighting system, occupancy sensor and other control devices. INSTALLATI WARNING TURN POWER OFF AT CIRCUIT BREAKER BEFORE INSTALLING POWER PACKS. WIRING 1. Make sure power has been turned off at the circuit breaker. 2. Connect wires as shown in the following wiring diagrams, or as shown in the BI-LEVEL CTROL section. Single with one or more sensors High Voltage Low Voltage Auto Man Optional Local Off Switch Fixture Blu Org Brn Gry Control Output + LVSW-101 Switch Input SW1 COM Any Ceiling/Wall * Refer to occupancy sensor data sheet to determine maximum number of sensors. Power pack ma output is 225mA. *To Additional (s) Call 800.879.8585 for Technical Support

Neut. +12- In Hold Dry +12- In Hold OFF White Orange Brown APPLIANCE CTROL 88T9 Control + Lighting Load Wires Momentary Switch (optional) with Hold On or Hold Off Auto Man Optional Local Off Switch Fixture Class 2 Wires 5-30 VDC In Hold Org Brn Blu Gry * Refer to occupancy sensor data sheet to determine maximum number of sensors. Power pack ma output is 225mA. 5-30 VDC In Hold OFF Dry Contact Control Output + Any Ceiling/Wall *To Additional (s) Installation Notes 1. Power packs should be installed in accordance with state, local and national electrical codes and requirements. 2. Power packs are designed to attach to existing or new electrical enclosures with 1/2 inch knockouts. 3. Most applications require UL listed, 18-22 AWG, 3-conductor, Class 2 cable for low voltage wiring. For plenum return ceilings, use UL listed plenum-approved cables. 4. The is a Class 2 Output Power Supply, suitable for parallel interconnection of up to 10 units maximum. This power pack is UL Listed for Interconnection of Power Sources in accordance with National Electric Code. OPERATI Mode Switch 120/230/, 50/60Hz, 225mA output 20A ballast or incandescent load Motor load: 1HP@120/240VAC Class 2 power supply UL 2043 Plenum Rated With the, the load can be turned and OFF automatically using an occupancy sensor input, a timer, panel or BAS input, and manually from an optional low voltage momentary switch. Use the Mode Switch to select either the Auto mode, or the Manual mode. Remove power from the when changing the switch setting, or cycle power to it after changing the setting. Model #: Auto Santa Clara, CA 800.879.8585 Manual Contact Blue Inputs 08405r1 Any 3-Wire Momentary Switch Option Wiring 2-wire Push Button Manual 3-wire Momentary, LVS-1 Manual Install Jumper Wire Multi-button Switch, L(x)S Do not use pilot or locator light connections S(x) Manual Com

Auto (Mode Switch LEFT - default) The occupancy sensor input, Hold input and the optional momentary switch input can all be used turn the load. When the load is turned OFF using the momentary switch, the does not turn it automatically until after the sensor time delay expires (e.g., as might be required for a presentation). Pressing the momentary switch before the sensor time delay expires turns the load. When the occupancy sensor s time delay expires, the BZ 150 reverts to Auto mode and it turns the load with the next input from the occupancy sensor. Manual (Mode Switch RIGHT) Occupants must press the low voltage momentary switch to turn the load. When the occupancy sensor is the only input keeping the load, the load turns OFF when the sensor s time delay expires. If the sensor input re-triggers within 30 seconds after the load turns OFF, the load turns again. After 30 seconds expire with no sensor input, press the momentary switch to turn the load. LOW VOLTAGE INPUTS Four +12- input wires are provided to control the load relay. The inputs may be used in combination or individually, depending on the needs of the application. See the WIRING section for wiring information. Maintained Inputs: Control (Blue) This input is intended for occupancy sensor input. Applying 12- closes the relay. Remove the voltage and the relay opens if no other input is holding it closed. Hold (Orange) This input is intended for timer or panel input. Applying 12- closes the relay. Remove the voltage and the relay opens if no other input is holding it closed. It overrides Control input. Hold OFF (Brown) This input is used for timer, panel, BAS or load shed input. Applying 12- opens the relay. Remove the voltage and the relay can accept any other input. It overrides Control and Hold inputs. Momentary Input: Manual /OFF () This input is for a low voltage momentary switch. Applying 12 momentary input changes the relay to the opposite state. It overrides Control, Hold and Hold OFF inputs.

BI-LEVEL CTROL WITH MANUAL The diagram to the right shows how to configure s to provide bilevel lighting control with both Automatic and Manual features. As shown, upon occupancy detection load A turns automatically. To turn load B the user must press momentary switch B. Both loads turn OFF automatically when the sensor time delay expires, or manually using switch A and B. Over Current Protection The contains built-in short circuit and thermal protection circuitry that shuts down the + output (low voltage red wire) to prevent permanent damage to the power pack. Removing the excess load from the output restores the to proper operation. Connect the excess load to another power pack. LED Indicator The LED on the reverse side of the indicates the following conditions: LED OFF: no power to the, or the + output is shorted. LED blinking continuously: current output limit is exceeded (too many sensors are connected to the power pack); + output shut down. LED, blinks once every 4 or 5 seconds: the relay is closed (load ). LED continuously: the relay is open (load OFF). TROUBLESHOOTING The lights came automatically after I deliberately turned them OFF for a presentation. Orange Auto Orange Auto The is set for the Auto Mode and the occupancy sensor time delay expired. The reverted to Auto and then motion was detected. Brown * Refer to occupancy sensor data sheet to determine maximum number of sensors. Power pack ma output is 225mA. Brown Man (A) Man (B) MANUAL AUTO Blue Blue Control Output + Fixture A (A) LVSW-101 Switch Input SW1 COM Any Ceiling/Wall Fixture B (B) LVSW-101 Switch Input SW1 COM *To Additional (s)

Consider increasing occupancy sensor sensitivity and/or time delay Generate more motion during presentations. The load does not turn with occupancy detection. Mode Switch is set to Manual. Hold OFF input is active. The load does not turn OFF after sensor time delay expires. Hold input is active. The load does not respond when I press the momentary switch. Check wiring. The load does not come on automatically although the Mode Switch is set to Auto. Cycle power to the unit to reset operating mode to Auto. Mode Switch location was changed while the power pack was was powered (line voltage). The load comes on automatically with occupancy although the Mode Switch is set to Manual. Cycle power to the unit to reset operating mode to Manual. Mode Switch location was changed while the power pack was was powered (line voltage). ORDERING INFORMATI Load Range Catalog No. Description Input Voltage BZ-50 120/, 50/60Hz, Hold /OFF, Manual 120/, 50/60Hz Ballast (A) Incan. (A) Motor (hp) Output 20 20 1, 225mA w/relay connected 20 20 1, 225mA w/relay connected WARRANTY INFORMATI WattStopper warranties its products to be free of defects in materials and workmanship for a period of five (5) years. There are no obligations or liabilities on the part of WattStopper for consequential damages arising out of, or in connection with, the use or performance of this product or other indirect damages with respect to loss of property, revenue or profit, or cost of removal, installation or reinstallation. 2800 De La Cruz Boulevard, Santa Clara, CA 95050 800.879.8585 www.wattstopper.com 08616r5 1/2016 Please Recycle