INSTALLATION GUIDE NI 9921/9922 Outdoor IP Enclosure For NI WLS-9000 Series Devices

Similar documents
INSTALLATION GUIDE NI WSN-3291 Outdoor IP Enclosure For NI WSN-32xx Series Devices

NI PS-15/16/17 Side Mount Brackets

NI Pin DSUB to Screw-Terminal Connector Block

Bracket and Assembly Dimensions

SAFETY INFORMATION & INSTALLATION GUIDE RMX Programmable Power Supplies. About the RMX Safety Information & Installation Guide

Shielded Connector Block for the NI PXI/PXIe-2532/2532B

Total credit to the non-financial sector (core debt), % of GDP Table F1.1

Infographics on Electromobility (January 2019)

WORLD MOTOR VEHICLE PRODUCTION BY COUNTRY AND TYPE QUARTERS June 14, 2018

GETTING STARTED GUIDE NI AI, ±10 V, 16 Bit, 1 MS/s/ch Simultaneous

GETTING STARTED GUIDE NI AI/1 Neutral, 400 Vrms L-N/690 Vrms L-L, 24 Bit, 50 ks/s/ch Simultaneous

GETTING STARTED GUIDE NI AI, ±10 V, 12 Bit, 500 ks/s Aggregate

NI 9251 with mini XLR

GETTING STARTED GUIDE NI DI, ±5 V to 24 V, Differential/Single-Ended, 500 ns

Global Dialysis - Cost per Dialysis Session

Lifting Instructions for 1336 PLUS and FORCE D Frame Drives

Spain s exports by oil product group and country of destination

GETTING STARTED GUIDE NI Channel Sinking Digital Input Module

GETTING STARTED GUIDE NI AO, ±10 V, 16 Bit, 25 ks/s/ch Simultaneous

Packing Data Installation Instructions

GETTING STARTED GUIDE NI DO, 5 V to 30 V, Sourcing, 1 μs

AUSTRIA. Table 1. FDI flows in the host economy, by geographical origin. (Millions of US dollars)

GETTING STARTED GUIDE NI DO, 6 V to 30 V, Sourcing, 100 μs

1. INTERNATIONAL OVERVIEW. 1.0 Area and population. population (1,000) area

BP Statistical Review of World Energy June 2017

Performance Derby: MSCI Regions/Countries Earnings & Revenues Growth 2019E / 2018E / 2017A

Primary energy. 8 Consumption 9 Consumption by fuel. 67 th edition

Rectangular photoelectric proximity switches

Spain s exports by oil product group and country of destination. Year Corporación de Reservas Estratégicas de Productos Petrolíferos

Photo courtesy of NZTA

M O T O R V E H I C L E S T A T I S T l C S

testing to perfection MultiTest-i Technical Datasheet

CALIBRATION PROCEDURE NI Channel, ±0.5 V, 24-Bit Simultaneous, Channel-to-Channel Isolated Analog Input Module

Imports of seed for sowing by country Calendar year 2011 Source: ISF compilation based on official statistics and international seed trade reports

UView Mini Transilluminator

Over time consistency of PPP results in the OECD countries

Information Technology and Economic Development: An Introduction to the Research Issues

GETTING STARTED GUIDE NI AI, 51.2 ks/s/ch Simultaneous, Universal Measurements

Fork through-beam sensors

THE WITTUR ANSWER TO THE MACHINE ROOMLESS MARKET REQUIREMENTS. MRL W Line. EMOTION IN MOTION

No.1. Side approach mechanism Precise lateral contacting. Catalogue 1.1. Test Probes Test Fixtures

Extraction arms for every type of application

GETTING STARTED GUIDE NI AI Differential/32 AI Single-Ended, ±200 mv to ±10 V, 16 Bit, 250 ks/s Aggregate

TOP SMART intelligent position monitor:

I. Global wine markets,

FEDERAL RESERVE statistical release


Made UNDER high pressure

Global Valuation Summary - SAMPLE PAGES

CALIBRATION PROCEDURE NI Channel, ±10 V, 16-Bit Analog Voltage Output Module

The new STx chain hoist NEW. Sophisticated technology prepared for the future

Allen-Bradley 1397 Pulse Encoder Interface Card

Product Overview INCH

MODERNISATION SOLUTIONS. MRM W Line. TIME FOR A FACE-LIFT!

SBS-Control. Table of contents. Operating Instructions BKS24-9A. Operating Instructions

Production of heat by type Terajoules

Fork through-beam sensors

EVOline Socket Modules

Electrophoresis + Blotting + Imaging. V3 Western Workflow Visualize. Verify. Validate.

MODERNISATION SOLUTIONS. MRM W Line. T I M E T O M A X I M I Z E YO U R S P A C E!

How to notify a waste shipment.

Global Economic Briefing: Merchandise Trade

Nevro Lead Compatibility

OECD unemployment rate stable at 5.8% in August 2017

Drive solutions for the oil and gas industry.

Thermal Coal Market Presentation to UNECE Ad Hoc Group of Experts on Coal in Sustainable Development December 7, 2004

Ceram 4-way Pneumatic Directional Control Valve Tough enough to survive, no matter where in the world you send it.

I. World trade in Overview

OECD unemployment rate stable at 5.3% in July 2018

STATISTISCHER ANHANG VORLÄUFIGE AUSGABE

Mechatronic brake system INTORQ Control

testing to perfection MultiTest-i Technical Datasheet

67 th edition. Renewable energy. Appendices. 44 Other renewables consumption 45 Biofuels production

Industrial Rack Mount Kit for CompactRIO and CompactDAQ

OECD unemployment rate down to 6.4% in March 2016

CrimpTest-1 kn. Calibration Bracket

Universal Charging and Testing Unit FPU-1 for Bladder, Piston and Diaphragm Accumulators

Civil Dialogue Group on WINE Thursday April 19th, 2018

OECD unemployment rate down to 6.5% in January 2016

FORGED STAINLESS STEEL Rack And Pinion Actuator S Series

SFC-FID ASTM System. SFC-4000 Series SFC. Performance Innovation Reliability

D6.. Butterfly valves. For controlled operation.

Test Probes Test Fixtures INGUN. Test Fixtures for low PCB volumes. Change made easy

OECD unemployment rate falls to 6.0% in March 2017

JURISDICTIONS PARTICIPATING IN THE CONVENTION ON MUTUAL ADMINISTRATIVE ASSISTANCE IN TAX MATTERS

Charging and testing unit FPU for Bladder, Piston and Diaphragm Accumulators

JURISDICTIONS PARTICIPATING IN THE CONVENTION ON MUTUAL ADMINISTRATIVE ASSISTANCE IN TAX MATTERS

Installation instructions

Standard Product Program. AirLINE & AirLINE Quick Type 8640 & Type 8644

Spain s imports by oil product group and country of origin

1204 Terminator. Instructions 1204 T F B2. (Catalog Number 1204-TFA1, 1204-TFB2) Where this Option is Used. What this Option Contains

Production of heat by type Terajoules

7 NK 72 en Issue 12/99 LIMIT SWITCHES. Series NK700 INSTALLATION, MAINTENANCE AND OPERATING INSTRUCTIONS

DOUBLE OCTOMILL TM PRODUCT RANGE

Annex IV. True nationality of the 20 largest fleets by flag of registration, as at 1 January 2011 a

United States 1,263, % % Total 3,150, % 97, %

Universal Charging and Testing Unit FPU-1 for Bladder, Piston and Diaphragm Accumulators

OECD unemployment rate stable at 5.4% in March 2018

European Aerosol Production 2016

Global Medium & Heavy Commercial Vehicle Model Level Production Forecast Report. From 2001 to 2021

Transcription:

INSTALLATION GUIDE NI 99/99 Outdoor IP Enclosure For NI WLS-9000 Series Devices This guide describes how to install and use the National Instruments 99 and National Instruments 99 outdoor IP enclosures. The NI 99/99 outdoor IP enclosures are accessories that provide NI WLS-9000 Series devices with a minimum ingress protection (IP) rating of IP54 against dust or water in harsh outdoor or industrial environments. Figure shows the NI 99/99 outdoor IP enclosure components. 4 3 8 7 6 5 IP Sleeve Antenna 3 IP Boot 4 DIN Rail Mounting Clip 5 Glands/Gaskets 6 M Trigger Connector (NI 99 Only) 7 M Power Connector 8 Ethernet Connector (NI 99 Only) Figure. NI 99/99 Outdoor IP Enclosure Components Note You need a # and # Phillips and a # flat screwdriver to install the NI 99/99. For more information about IP ratings, refer to the Understanding IP Ratings section. For the NI WLS-9000 Series device specifications, refer to the NI WLS/ENET-963 User Guide and Specifications available at ni.com/manuals.

ETHERNET POWER TRIGGER I/O I/O Dimensions The NI 99/99 kit includes the following items: NI 99/99 One Ethernet field termination connector kit One Ethernet end cap One M trigger male field termination connector kit One M trigger end cap One M power female field termination connector kit One M power end cap M5 gland clamps Two glands, split Two glands, blanking plugs Four 4 0 Plastite screws (included in DIN rail kit).4 GHz antenna One IP Boot One IP Sleeve DIN rail mounting clip Two small zip ties Figure shows the NI 99/99 dimensions. 79 mm (3.8 in.) 8 mm (.77 in.) 60 mm (6.30 in.) 63.3mm (.49 in.) 360 mm (4.7 in.) mm (0.83 in.) 9 mm (3.58 in.) 9 mm (3.58 in.) Figure. NI 99/99 Dimensions Not included with the NI 99. NI 99/99 Outdoor IP Enclosure Installation Guide ni.com

Mounting the NI 99/99 Figure 3 shows the NI 99/99 mounting hole dimensions. NI recommends mounting the NI 99/99 before installing the NI WLS-9000 Series device and attaching the internal and external cables. Tip Attach the cover after mounting the NI 99/99 and installing the NI WLS-9000 Series device. 6.5 mm (4X Ø.5 in.) 0 mm (4.33 in.) 340 mm (3.39 in.) Setting Up and Installing the NI 99/99 Figure 3. NI 99/99 Mounting Hole Dimensions and Locations Complete the following steps to set up and install the NI 99/99: Step : Unpack and Inspect the Kit Contents Remove the device from the package and inspect the device and kit contents. Contact NI if the device appears damaged. Do not install a damaged device or use kit contents that appear damaged. Step : Unscrew and Detach the Cover The cover of the NI 99/99 is equipped with captive screws. Use a # Phillips screwdriver to remove the cover as shown in Figure. National Instruments Corporation 3 NI 99/99 Outdoor IP Enclosure Installation Guide

Step 3: Install the NI WLS-9000 Series Device Complete the following steps to install the NI WLS-9000 Series device into the NI 99/99:. Use the # Phillips screwdriver and the four 4 0 Plastite screws to attach the DIN rail clip to the NI WLS-9000 Series device, as shown in Figure 4. Figure 4. Attaching DIN Rail Clip to NI WLS-9000 Series Device. Snap the NI WLS-9000 Series device onto the DIN rail of the NI 99/99 outdoor IP enclosure, as shown in Figure 5 and Figure 6. Figure 5. Connecting the NI WLS-9000 Series Device to the NI 99/99 DIN Rail Clip DIN Rail Figure 6. Attaching DIN Rail Clip to the DIN Rail (Shown Without Device) NI 99/99 Outdoor IP Enclosure Installation Guide 4 ni.com

Step 4: Connect Internal Cables The NI 99/99 ships with internal cables to connect the NI WLS-9000 Series device to the IP rated connectors that are on the inside of the NI 99/99. Refer to Figure 7 while completing the following steps to connect the internal cables to the NI 99/99 to the NI WLS-9000 Series device: 6 5 4 3 Antenna Internal Trigger Cable (NI 99 Only) 3 Internal Power Cable 4 Internal RJ45 Ethernet Cable (NI 99 Only) 5 Internal Antenna Cable 6 IP Sleeve Figure 7. Connecting Internal Cables. Connect the internal RJ45 Ethernet cable to the NI 99 and the NI WLS-9000 Series device.. Connect the internal antenna cable from the NI 99/99 to the NI WLS-9000 Series device. 3. Connect the internal trigger cable from the NI 99 to the NI WLS-9000 Series device. 4. Connect the internal power cable from the NI 99/99 to the NI WLS-9000 Series device. National Instruments Corporation 5 NI 99/99 Outdoor IP Enclosure Installation Guide

Step 5: Install the Antenna Refer to Figure 8 to install the antenna assembly. 3 4 5 IP Boot Enclosure 3 External Antenna Connector 4 Antenna Figure 8. Antenna Assembly Installation 5 IP Sleeve On the outside of the enclosure, place the IP boot onto the external antenna connector with the smaller diameter hole out. Screw the antenna onto the external antenna connector until it bottoms out. Slide the IP sleeve down the antenna and over the IP boot until the IP sleeve touches the enclosure. NI 99/99 Outdoor IP Enclosure Installation Guide 6 ni.com

Step 6: Attach External Cables NI IP Rated Cables Table lists the optional cable accessories for use with the NI 99/99. Go to ni.com for more information about these accessories. Table. Optional Cable Accessories NI Part Number Description 96648 05 IP rated, 5 meter M power cable, pigtail 96649 05 IP rated, 5 meter M trigger cable, pigtail 96650 05 IP rated, 5 meter Ethernet cable 96647 0 Cable gland replacements: two solid glands and four assorted two-hole split glands Building and Connecting IP Rated Cables You can order IP rated cables from NI or you can use the field termination connectors that are shipped with the NI 99/99 outdoor IP enclosure to make your own cable lengths. Caution Only use the connectors provided with the NI 99/99 when building your cables. The following field termination connectors are included in the NI 99/99 kit for creating custom cable connectors: One M power female field termination connector kit (connects to power) One M power end cap The following field termination connectors are also included with the NI 99: One Ethernet field termination connector kit. Refer to documentation included in the Ethernet field termination connector kit for assembly instructions. One Ethernet end cap One M trigger male field termination connector kit (connects to trigger) One M trigger end cap Note Be sure to route the wires through the plastic and rubber sealing grommets and the backshell before connecting to the screw terminals on the M field termination connectors. Building an M Field Termination Cable To build an M field termination cable with the connector included with the NI 99/99, refer to the following sections. Female M Field Termination Cable On the M power female field termination connector, connect the positive lead of the primary power supply to Pin 4 and the negative lead to Pin 3. National Instruments Corporation 7 NI 99/99 Outdoor IP Enclosure Installation Guide

4 3 3 4 The pin number is marked on the inside of the field termination connector, next to the respective terminal, as shown in Figure 9. Male M Field Termination Pinout Female M Field Termination Pinout Figure 9. Male and Female M Termination Connector Pinouts Male M Field Termination Cable On the M Trigger male field termination connector, connect PFI 0 to the Pin 4, PFI to Pin, and Ground to Pins and 3. The pin number is marked on the inside of the field termination connector, next to the respective terminal, as shown in Figure 9. Building an IP Rated RJ45 Cable Refer to the SCPFE Assembly/Wiring Instructions document included in the field termination connector kit for instructions about how to build an IP rated Ethernet cable. Refer to Figure 0 while completing the following steps to attach the external cables: 5 3 4 Ethernet Cable M Power Cable 3 M Trigger Cable 4 Glands/Gaskets 5 I/O Cables Figure 0. Connecting External Cables/Components NI 99/99 Outdoor IP Enclosure Installation Guide 8 ni.com

. Connect external IP rated cables to the external Ethernet connector and the external M power and trigger connectors.. The two-piece gland system allows prefabricated cables to route I/O out of the NI 99/99. When the correct cable gland is selected, it meets a minimum IP rating of IP54. For more information about IP ratings, refer to the Understanding IP Ratings section. Glands with two holes route two cables at once. Blank glands are also provided, allowing for custom cable configuration. Note To ensure that the NI WSL-9000 Series device meets specified requirements, use one of the glands to route ground outside of the NI 99/99 outdoor IP enclosure. To use the two-piece gland system, complete the following steps:. Choose the appropriately sized grommet for the cable diameter width. Blank plugs are provided for use with custom cable sizes.. Place the grommet around the cable. 3. Press the grommet containing cable into the open cable gland. 4. Press the two halves of the cable gland together until they lock together. 5. Place the provided seal over the thread and place the cable gland into the holes, as shown in Figure 0. 6. Secure the gland with the provided nut. Step 7: Attach the Cover The cover of the NI 99/99 is equipped with captive screws. Use a # Phillips screwdriver to install the cover as shown in Figure. Figure. Attaching the NI 99/99 Cover National Instruments Corporation 9 NI 99/99 Outdoor IP Enclosure Installation Guide

Understanding IP Ratings Proper use and installation of an NI WLS-9000 Series device in an NI 99/99 outdoor IP enclosure provides a minimum IP rating of IP54 from harsh outdoor and industrial environments. An IP rating of IP54 protects against entry by dust particles and splashing water from all directions. The two-digit ingress protection (IP) rating is defined by the IEC 6059 standard and specifies the degree to which the enclosures protect against the intrusion of solid particles (represented by the first digit) and water (represented by the second digit). Table lists the degree of protection. Table. IP Ratings First Number (Protection Against Solid Objects) Second Number (Protection Against Water) 0 No protection 0 No protection Protects against objects greater than 50 mm Protects against vertically dripping water Protects against objects greater than.5 mm Protects against direct sprays up to 5 from vertical 3 Protects against objects greater than.5 mm 3 Protects against direct sprays up to 60 from vertical 4 Protects against objects greater than mm 4 Protects against direct sprays from all angles 5 Dust-protected (no harmful deposit) 5 Protects against low pressure water jets 6 Dust-tight 6 Protects against high pressure water jets 7 Immersible in water up to m 8 Immersible in water beyond m Environmental Management NI is committed to designing and manufacturing products in an environmentally responsible manner. NI recognizes that eliminating certain hazardous substances from our products is beneficial to the environment and to NI customers. For additional environmental information, refer to the NI and the Environment Web page at ni.com/environment. This page contains the environmental regulations and directives with which NI complies, as well as other environmental information not included in this document. Waste Electrical and Electronic Equipment (WEEE) EU Customers At the end of the product life cycle, all products must be sent to a WEEE recycling center. For more information about WEEE recycling centers, National Instruments WEEE initiatives, and compliance with WEEE Directive 00/96/EC on Waste and Electronic Equipment, visit ni.com/environment/weee. RoHS National Instruments (RoHS) National Instruments RoHS ni.com/environment/rohs_china (For information about China RoHS compliance, go to ni.com/environment/rohs_china.) NI 99/99 Outdoor IP Enclosure Installation Guide 0 ni.com

Where to Go for Support The National Instruments Web site is your complete resource for technical support. At ni.com/ support you have access to everything from troubleshooting and application development self-help resources to email and phone assistance from NI Application Engineers. National Instruments corporate headquarters is located at 500 North Mopac Expressway, Austin, Texas, 78759-3504. National Instruments also has offices located around the world to help address your support needs. For telephone support in the United States, create your service request at ni.com/ support and follow the calling instructions or dial 5 795 848. For telephone support outside the United States, contact your local branch office: Australia 800 300 800, Austria 43 66 457990-0, Belgium 3 (0) 757 000, Brazil 55 36 3599, Canada 800 433 3488, China 86 5050 9800, Czech Republic 40 4 35 774, Denmark 45 45 76 6 00, Finland 358 (0) 9 75 75, France 0 57 66 4 4, Germany 49 89 74330, India 9 80 490000, Israel 97 3 6393737, Italy 39 0 430977, Japan 00-5796, Korea 8 0 345 3400, Lebanon 96 (0) 33 8 8, Malaysia 800 88770, Mexico 0 800 00 0793, Netherlands 3 (0) 348 433 466, New Zealand 0800 553 3, Norway 47 (0) 66 90 76 60, Poland 48 38 90 0, Portugal 35 0 3 0, Russia 7 495 783 685, Singapore 800 6 5886, Slovenia 386 3 45 4 00, South Africa 7 0 805 897, Spain 34 9 640 0085, Sweden 46 (0) 8 587 895 00, Switzerland 4 56 0055, Taiwan 886 0 377, Thailand 66 78 6777, Turkey 90 79 303, United Kingdom 44 (0) 635 53545 National Instruments Corporation NI 99/99 Outdoor IP Enclosure Installation Guide

LabVIEW, National Instruments, NI, ni.com, the National Instruments corporate logo, and the Eagle logo are trademarks of National Instruments Corporation. Refer to the Trademark Information at ni.com/trademarks for other National Instruments trademarks. Other product and company names mentioned herein are trademarks or trade names of their respective companies. For patents covering National Instruments products/technology, refer to the appropriate location: Help»Patents in your software, the patents.txt file on your media, or the National Instruments Patent Notice at ni.com/patents. 009 00 National Instruments Corporation. All rights reserved. 3750C-0 Jul0