Voltmaster Centrifugal Trash Pumps

Similar documents
TP300 INDUSTRIAL TRASH PUMP OPERATOR S MANUAL

Owner s Manual. Original Instructions for Assembly, Testing, Operation, Servicing, and Storage

Owner s Manual. Original Instructions for Assembly, Testing, Operation, Servicing, and Storage

PORTABLE TRASH PUMPS MDP200

PORTABLE TRASH PUMPS MTP200 MTP300 MTP400

OWNER S MANUAL MODEL TTP-300 3X3 Commercial Trash Pump

Owner s Manual. Water Pump: Outdoor agricultural product used for general purpose water pumping, field irrigation and trash applications.

Propane torch. Model Assembly And Operation Instructions

Table of Contents. Safety symbols... 3 Assembly 6. Operation Maintenance Troubleshooting 11. Storage. 12. Notes. 13

Read instructions carefully and follow rules for safe operation. Failure to do so could result in serious injury. Fradan Manufacturing Corp.

Hydraulic PTO Flow Device

UNPACKING SAFETY GUIDELINES GENERAL SAFETY INFORMATION. Operating Instructions & Maintenance Manual

Operating and Maintenance Manual Gas/Diesel Engine Powered Self-Priming Centrifugal Pumps Series

ENGINE DRIVEN 3 FULL TRASH PUMP

Pump Owner s Manual. PLEASE! Read All Instructions Carefully Before Installing Pump

Operating and Maintenance Manual Gas & Diesel Engine Powered Self-Priming Trash Pumps Series

Hydraulic Immediate Need Power Pack

North Dakota State University Grounds Maintenance Equipment

Operation Manual. 21 Inch Self-Propelled Lawn Mower MODEL #

Airless Spray Gun INSTRUCTIONS DP psi (345 bar) Maximum Working Pressure

3" & 4" Cast Iron Self-Priming Centrifugal Pump Instruction Manual

1-1/2 DIAMETER WATER PUMP

Stainless Steel Rotary Drum Pump

Operating and Maintenance Manual Gas & Diesel Engine Powered Diaphragm Pumps. Series 55A

Centrifugal Pumps (Part Nos. PS2SS PS73SS) PS2SS

2-in-1 Air Operated Waste Oil Drainer

PROPANE TORCH WITH TURBO BURNER

en Vibroplate VP 1550 (RAW) OPERATOR S MANUAL

Log Splitter. Owner/Operator Manual. Models HCWP1-26

316 Series Engine Driven DESCRIPTION MAINTENANCE SHIM ADJUSTMENT. Specifications Information and Repair Parts Manual

MAINTENANCE CLEANING. MECHANICAL SEAL REPLACEMENT Refer to figures 1 and 2. SHIM ADJUSTMENT

MANUAL FLUID EXTRACTOR

MODEL HD99 HYDRAULIC ONE MAN TOWABLE EARTHDRILL

Installation Instructions for Aux 101 Kit A044Z055

AIR COMPRESSOR OPERATING INSTRUCTION AND PARTS LIST

Operation Manual. 10 Mini-Cultivator MODEL #

MGFHVLP. Instructions/Parts. Mini Gravity Feed System E. Part No Includes MGFHVLP Mini Gravity Feed Spray Gun and MGC 125 Gravity Cup.

Polypropylene Piston Drum Pumps

DISPLACEMENT PUMP INSTRUCTIONS-PARTS LIST Rev. K. Model , Series A Model , Series B Model , Series A

MOTORVAC TECHNOLOGIES INC. TRANSTECH-1000 Transmission Service System

1/2 HP CAST IRON TRANSFER PUMP

Cast Iron Rotary Drum Pump

OWNER S MANUAL EVOLUTION 3500, 4500, 5500, & 8500 SERIES PUMPS

1/2" AIR DRIVEN DIAPHRAGM PUMP

115 VOLT TRANSFER PUMP

D Instructions/Parts. Siphon Feed Detail Spray Gun D

GeyserMax-Flow Series

WARNING! Decals. IMPORTANT INFORMATION Xxxx xxx xxxx xx xxxx x xxxx. Xxxx xxx xxxx xx xxxx x xxxx.

AG-HA-2500N GASOLINE GENERATOR

JOHN DEERE WORLDWIDE COMMERCIAL & CONSUMER EQUIPMENT DIVISION. Lawn Tractors L100, L110, L120, and L130 TM2026 DECEMBER 2002 TECHNICAL MANUAL

Matala. VersiFlow Series. Instruction and Maintenance Manual

Model &

IPT SERIES 2P5X, 2S5X AND 3S5X PUMPS Refer to pump manual for General Operating and Safety Instructions.

FSG175 FENCE STAPLE GUN

PARTS AND INSTALLATION MANUAL

Professional Séries. Professional Séries. Model T03828 SUBMERSIBLE SUMP DUPLEX SYSTEM SUBMERSIBLE SUMP DUPLEX SYSTEM. 1/3HP 2400 GPH Head of 20 (6 m)

Water pump Owner's Manual

T1-Titanium Non-HVLP Spray Gun

5.5KVA GENERATOR MODEL NO: PG6500DVES OPERATION & MAINTENANCE INSTRUCTIONS PART NO: LS0616

100 Gallon Skid Sprayer

Air-Operated Waste Oil Drainer

3KVA DUAL VOLTAGE GENERATOR MODEL NO: PG3800DV

44,400mWh LITHIUM-POLYMER CAR JUMP STARTER USER S MANUAL PLEASE READ THIS MANUAL CAREFULLY BEFORE OPERATION

UNPACKING SAFETY GUIDELINES GENERAL SAFETY INFORMATION. Operating Instructions & Maintenance Manual

1100W PORTABLE GENERATOR

OWNER S MANUAL SELF-PRIMING PORTABLE UTILITY PUMP

GENERATOR MODEL NO: FG3000 OPERATION & MAINTENANCE INSTRUCTIONS PART NO: LS0609

OWNER'S MANUAL WARNING DANGER. Propane cylinders sold separately. The propane cylinder must be disconnected when this firebowl is not use.

OWNER S MANUAL. Item #

MODELS 58, 903. Intake Hose Kit for LBC Series 1 Walk- Behind Leaf Blowers For Leaf Blower models: LBC55151BV LBC915751BV

9000RC INDUSTRIAL GASOLINE GENERATOR OPERATOR S MANUAL

Page 1 of 12. Part# /30/2016

OPERATION & MAINTENANCE INSTRUCTIONS

WARNING Carefully Read These Instructions Before Use

Installation Instructions for Remote Mount HMI 211 Display Panel Kit A045J206

ECSS. Electric Chain Saw Chain Sharpener Assembly & Operating Instructions

SIP Direct Drive Oil-Lube Air Compressors - Operating & Maintenance Instructions

Owner s Manual Instructions for Installation/Set-up, Operation, Servicing, & Storage

DIRECT-DRIVE PRESSURE WASHERS

GARDEN HOSE UTILITY PUMP

M-3025CB-AV Fuel Pump

Cordless Rechargeable Saw Instructions for Use

Owner s/operator s Manual

DIRECT-DRIVE PRESSURE WASHERS

Operation Manual. All Terrain Power Cart MODEL #

1/4 ANGLE DIE GRINDER

15-GALLON OIL DRAIN DOLLY WITH 12 VOLT PUMP

Model: HT9605H HT0165B. Hurricane Plus OPERATION SERVICE PARTS CARE. Revised 9/04

Flow Max. by Duraself. Flow Max by Duraself. Fluid Pump. Installation and Owner s Manual (For Aftermarket Applications)

UNPACKING SAFETY GUIDELINES GENERAL SAFETY INFORMATION. Operating Instructions & Maintenance Manual

8500M INDUSTRIAL GASOLINE GENERATOR OPERATOR S MANUAL

STEP-BY-STEP INSTALLATION GUIDE

END SUCTION CENTRIFUGAL PUMPS

PEDESTAL SUMP PUMP. MODEL # Español p. 11. Zoeller is a registered trademark of Zoeller Co. All Rights Reserved.

Submersible Pump Instructions. Safety Instructions

Decals. IMPORTANT INFORMATION Xxxx xxx xxxx xx xxxx x xxxx. WARNING! Xxxx xxx xxxx xx xxxx x xxxx.

IMPORTANT SAFETY NOTICE

GENERATOR MODEL NO: FG3005 OPERATION & MAINTENANCE INSTRUCTIONS PART NO: LS0413

Panther HP Oil Pump Series

STRAIGHT DIE GRINDER MODEL EGA530 OWNERS MANUAL

Transcription:

Voltmaster Centrifugal Trash Pumps Model TSP2, TSP3 and TSP4 Owner s Manual February 2011

Table of Contents 1 Introduction............................ 1 1.1 Read before using..................... 1 1.2 Where to obtain service............... 1 2 Safety Information................... 3 2.1 Operating safety...................... 3 2.2 Engine safety......................... 5 2.2.1 Operator safety............... 5 2.2.2 California Proposition 65...... 6 2.2.3 Spark arresters............... 6 2.3 Storage and maintenance safety....... 7 3 Operation................................ 9 3.1 Before starting........................ 9 3.1.1 Safety........................ 9 3.1.2 Flow considerations.......... 9 3.1.3 Installation................... 10 3.2 Operating the pump.................. 11 3.2.1 Priming time................. 12 3.2.2 Flow control.................. 12 4 Troubleshooting...................... 13 4.1 Common problems................... 13 4.2 Parts lists............................. 14 Owner s Manual i

List of Figures Figure 4.1 Trash pump exploded view............ 14 List of Tables Table 4.1 Table 4.2 Table 4.3 Parts list for Model TSP2, 2-inch trash pump................ 15 Parts list for Model TSP3, 3-inch trash pump................ 16 Parts list for Model TSP4, 4-inch trash pump................ 17 ii Owner s Manual

1 Introduction 1.1 Read before using This is a gas engine powered, industrial strength trash pump. The gas engine and the pump are both potentially hazardous and could cause physical injury or even death if improperly used. Before attempting to operate this unit: Check to ensure no damage has occurred in transit Read this manual thoroughly Follow all instructions carefully Read the engine manufacturer's instructions By following these instructions, you will enjoy safe and trouble-free operation of your trash pump. 1.2 Where to obtain service Before calling for service, please have the unit s model number and serial number ready. This information is displayed on the serial number tag, which is adhered to the trash pump. Contact our service department using the following information: Wanco Inc. 5870 Tennyson Street Arvada, Colorado 80003 800-730-3927 fax 303-427-5725 www.voltmaster.com sales@voltmaster.com Owner s Manual 1

2 Owner s Manual

2 Safety Information 2.1 Operating safety DANGER Explosion hazard. NEVER use for pumping flammable, corrosive, or combustible fluids. NEVER operate the pump in an explosive atmosphere or near combustible materials. WARNING Improper use of equipment could cause serious injury or death. Prior to using this product, carefully read, understand, and observe all instructions in this manual and the engine manual. DO NOT operate or service this equipment before reading this entire manual. This equipment should not be operated by persons under 18 years of age. ALWAYS wear appropriate protective clothing, shoes, and other protective devices, as required by the job. ALWAYS wear appropriate respiratory, hearing, and eye protection. NEVER operate this equipment when not feeling well due to fatigue, illness, or medication. NEVER operate this equipment under the influence or drugs or alcohol. Owner s Manual 3

Before operating, ensure pump is on a firm, flat, level surface. If located next to a pit or hole, ensure pump is anchored so that it cannot fall in. Before operating, know the location of the nearest fire extinguisher, first aid kit, and emergency telephone. NEVER pump corrosive chemicals or water containing toxic substances. These fluids could create serious health and environmental hazards. Contact local authorities for assistance. NEVER use pump with any safety guards removed. NEVER leave the pump unattended while it is running. Turn off engine when unattended. NEVER service pump or its components while pump is running. Moving parts and water inside pump can be unpredictably dangerous while pump is running. Never perform service or maintenance while pump or engine is hot. NEVER block or restrict discharge flow. Remove kinks from discharge line before starting pump. Operation with a blocked discharge line can cause water inside pump to overheat. Use ONLY accessories or attachments that are recommended by the manufacturer. Unauthorized equipment modifications will void all warranties. 4 Owner s Manual

2.2 Engine safety 2.2.1 Operator safety DANGER Explosion hazard. Keep engine, fuel, and other combustibles away from sparks, open flame, and burning objects. Do not smoke near engine. Stop engine before filling or draining fuel tank. Use correct fuel. Replace fuel tank cap after refueling. Do not use gasoline, other fuels, or flammable solvents to clean parts. DANGER Asphyxiation hazard. Engine exhaust contains carbon monoxide, a poison gas you cannot see or smell. NEVER operate indoors, EVEN IF doors and windows are open. Operate the engine OUTSIDE, far away from doors, windows, and vents. Refill and drain fuel tank only in a well ventilated area. Perform maintenance in a well ventilated area. Owner s Manual 5

WARNING Fire hazard. A hot muffler can ignite flammable materials. Keep area around muffler free of debris such as leaves, paper, and cartons. Refer to engine manufacturer s documentation for additional engine safety and operating information. 2.2.2 California Proposition 65 2.2.3 Spark arresters IMPORTANT! CAUTION Risk of severe burn. Do not touch the engine, exhaust pipes, or any engine component until cool. Do not remove radiator cap when engine is hot. Contents are hot and under pressure. WARNING Health hazard. Engine exhaust and some of its constituents are known to the State of California to cause cancer, birth defects, and other reproductive harm. State and local safety codes specify that, in certain locations, internal combustion engines that use hydrocarbon fuels must be used with spark arresters. A spark arrester is a device constructed of nonflammable materials specifically for the purpose of removing and retaining carbon and other flammable particles from the exhaust flow of an internal combustion engine. 6 Owner s Manual

Spark arresters are qualified and rated by the United States Forest Service. To comply with all applicable laws regarding spark arresters, consult your local Health and Safety Administrator. 2.3 Storage and maintenance safety When not in use, store equipment in a clean, dry location out of the reach of children. Before storing: Drain fuel Drain water and fluids that could freeze Drain fluids that contain solids that could settle or crystallize Drain fluids that may leave a solid or sticky residue inside the pump ALWAYS keep the pump in proper running condition. Before servicing, ensure the power unit cannot be inadvertently started during service. ALWAYS fix damage to the pump immediately. Repair or replace broken or worn parts. Only use parts from original manufacturer. Replace operation and safety decals when they become difficult to read. Dispose of hazardous waste in accordance with all applicable codes and ordinances. Examples of potentially hazardous waste include motor oil, fuel, and fuel filters. NEVER use plastic or food containers to dispose of hazardous waste. NEVER pour waste, oil, or fuel directly onto the ground, down a drain, or into any water source. Owner s Manual 7

8 Owner s Manual

3 Operation 3.1 Before starting 3.1.1 Safety Before operating the Voltmaster Trash Pump: Read and be familiar with this instruction manual. Read and follow all safety instructions (see Section 2.1, page 3). Read and follow instructions in the engine manufacturer s documentation. CAUTION 3.1.2 Flow considerations An overheated pump can be extremely hot, resulting in severe burns. Stop pump immediately if overheating occurs. Then, slowly and with great caution, vent pump at drain plug. Ensure the power unit, pump, wiring, and piping installations are suitable for the fluid being pumped and comply with all applicable codes and ordinances. DO NOT expose pump to extremes conditions of acidity or basicity. If necessary, consult factory for specific recommendations regarding chemicals and temperatures. Drain the pump whenever there is a danger of freezing. Overheating can occur if either the suction or discharge becomes restricted. If flow becomes restricted, refer to Section 4, Troubleshooting, page 13. Owner s Manual 9

Before operating, ensure pump is on a firm, flat, level surface. If pump is located next to a pit or hole, ensure pump is anchored so that it cannot fall in. Locate pump as close to the level of the fluid to be pumped, but never higher than 25 feet (7.5m) above fluid surface. Keep hoses and piping straight and as short as possible, avoiding sharp bends. If hoses must be laid across a roadway, protect it with planking. Instantaneous shutoff pressure, applied when a vehicle runs over an unprotected hose, will cause hydraulic shock and may damage the pump. If the discharge line runs vertically more than 30 feet (9m), it is advisable to install a check valve in the discharge line, near the pump, to stop destructive liquid hammer when the pump is shut down. If a check valve is installed, it may be necessary to vent the top of the pump so that air can be expelled during automatic priming. This can be accomplished by providing a 1/4-inch (0.5cm) line from the top of the pump back to the fluid source. If a check valve is not installed, the manufacturer cannot assume responsibility for damage to the pump due to destructive liquid hammer. 3.1.3 Installation 1. Install a suction strainer at the suction hose or pipe: A strainer is provided with holes or slots small enough to prevent larger particulate matter from entering and damaging the pump. The strainer should be installed into the suction end of the line, before piping enters the pump. The strainer should be positioned so it will remain completely under water. Running the pump with the strainer above water for long periods can damage the pump. If possible, suspend the strainer to keep it from working into the sediment. Alternatively, set the strainer on a bed of stones or tie it inside a basket or pail. During operation, the strainer should be kept clean to optimize flow. 10 Owner s Manual

2. Make plumbing connections to the pump using at least 12 inches (30cm) of flexible hose. Rigid piping may put stresses on the pump, resulting in damage to equipment. If rigid piping is necessary, properly support the piping to eliminate stresses on the pump. Use sealant on all threaded connections. Ensure connections, drain, and filter plugs are tight but not overtightened. Excessive force on connections may damage threads or the pump body. Ensure proper connection of hose and piping. Air leaks in the suction line may prevent priming and reduce pumping capacity. 3. Fill the pump with liquid through the priming port on top of the pump. DO NOT run pump dry. Always fill the pump body with water before starting. The pump is self-priming when filled with water. 4. Prepare for starting the engine: a. Observe all engine safety precautions in Section 2.2, page 5. b. Check engine oil, fuel, and coolant levels. Use proper fuel. c. If the fuel tank was drained or run dry, it might be necessary to prime the fuel lines. Refer to the engine manual for instructions. 3.2 Operating the pump 1. Before operating the pump, follow all instructions in Section 3.1. 2. Start the engine, referring to engine manufacturer s instructions if necessary. 3. To manage the flow, refer to the following sections. Owner s Manual 11

3.2.1 Priming time At sea level, with a suction lift from 5 to 10 feet (1.5 to 3 meters), the pump should discharge fluid in less than 1minute. A suction lift of up 25 feet (7.6m) requires less than 2 minutes. Priming time will increase with increased elevation above sea level. To reduce priming time, the engine speed may be increased (after the engine is properly broken in; see engine documentation). If fluid is not flowing within the time specified above, shut off the pump and check plumbing to determine whether the flow line is the problem. See Section 4, Troubleshooting. 3.2.2 Flow control On high suction lifts, engine speed must be increased. On shallow lifts or when there is little fluid to be pumped, fuel usage may be reduced and engine life increased may be by lowering the engine speed. Refer to the engine documentation for additional information. 12 Owner s Manual

4 Troubleshooting 4.1 Common problems For troubleshooting, check and resolve the following issues as needed. Contact the factory for assistance if necessary (see Section 1.2, Where to obtain service, page 1). If the pump fails to prime: The priming chamber might be empty or not sufficiently full Liquid in priming chamber might be overheated The direction of rotation might be reversed Rotation speed might be too slow The impeller or volute might be worn or broken Delivery line might be under pressure There could be air leaks in the suction-line or at joints in the line, loose screws at joints in the line, or broken hoses in the line There could be an air leak through a damaged mechanical seal Quick-coupling gaskets might be broken or improperly mounted Hose clamps might be loose or broken If capacity is low: The suction strainer might be clogged The suction or delivery line might be obstructed There could be high-friction losses in the suction line, which may require eliminating bends in the line or restrictions from valves The suction lift could be too high The rotation speed might be too slow The impeller might be clogged Owner s Manual 13

4.2 Parts lists Figure 4.1 Trash pump exploded view 14 Owner s Manual

Table 4.1 Parts list for Model TSP2, 2-inch trash pump Item Description Qty. Item Description Qty. 1 Honda engine 5.5HP 1 20 O-ring, housing cover screw 4 2 Pump adapter 1 21 O-ring, housing cover 1 3 Washer 4 22 Housing cover 1 4 Serrated bolt 5/16"-24 x 3/4" - SS 4 23 Washer 3/8" 4 5 Knob 3/8"-16 4 24 O-ring, cleaning port cover 1 6 Engine adapter 1 25 Cleaning port cover 1 7 Washer 4 26 Bolt 5/16"-18 x 7/8" 2 8 Bolt 4 27 Flapper valve 2" 1 9 Seal sleeve 3"/4" T 1 28 Suction flange 2" 1 10 Seal & seal seat 2" T S 1 29 Bolt 8 11 SS impeller shim 1 30 Discharge gasket 2" 1 12 O-ring, pump housing 1 31 Discharge elbow 2" 1 13 Impeller 2" T CI 1 32 O-ring 2 14 Volute 2" TL CI 1 33 Male hose barb 2" 2 15 Volute gasket 2" 1 34 Hose nut 2" 2 16 Pump housing 2" 1 35 Suction strainer 2" 1 17 Bolt 3/8"-16 x 1 1/2" 8 36 Nut 4 18 O-ring, drain/filler plug 2 37 Bolt 4 19 Drain/filler plug 1/2" 2 38 Roll cage assembly S 1 Owner s Manual 15

Table 4.2 Parts list for Model TSP3, 3-inch trash pump Item Description Qty. Item Description Qty. 1 Honda engine 8HP or Honda engine 9HP 1 20 O-ring, housing cover screw 4 2 Pump adapter 1 21 O-ring, housing cover 1 3 Washer 4 22 Housing cover 1 4 Serrated bolt 5/16"-24 x 3/4" SS 4 23 Washer 3/8" 4 5 Knob 3/8"-16 4 24 O-ring, cleaning port cover 1 6 Engine adapter 1 25 Cleaning port cover 1 7 Washer 4 26 Bolt 5/16"-18 x 7/8" 2 8 Bolt 4 27 Flapper valve 4" 1 9 Seal sleeve 3"/4" T 1 28 Suction flange 3" 1 10 Seal & seal seat 3"/4" T S 1 29 Bolt 3/8"-16 x 1" 8 11 SS impeller shim 1 30 Discharge gasket 4" 1 12 O-ring, pump housing 1 31 Discharge elbow 3" 1 13 Impeller 3" T CI 1 32 O-ring 2 14 Volute 3" T CI 1 33 Male hose barb 3" 2 15 Volute gasket 4" 1 34 Hose nut 3" 2 16 Pump housing 4" 1 35 Suction strainer 3" 1 17 Bolt 3/8"-16 x 2" 8 36 Nut 4 18 O-ring, drain/filler plug 2 37 Bolt 4 19 Drain/filler plug 3/4" 2 38 Roll cage assembly L 1 16 Owner s Manual

Table 4.3 Parts list for Model TSP4, 4-inch trash pump Item Description Qty. Item Description Qty. 1 Honda engine 13HP 1 20 O-ring, housing cover screw 4 2 Pump adapter 1 21 O-ring, housing cover 1 3 Washer 4 22 Housing cover 1 4 Serrated bolt 5/16"-24 x 3/4" SS 4 23 Washer 3/8" 4 5 Knob 3/8"-16 4 24 O-ring, cleaning port cover 1 6 Engine adapter 1 25 Cleaning port cover 1 7 Washer 4 26 Bolt 5/16"-18 x 7/8" 2 8 Bolt 4 27 Flapper valve 4" 1 9 Seal sleeve 3"/4" T 1 28 Suction flange 4" 1 10 Seal & seal seat 3"/4" T S 1 29 Bolt 3/8"-16 x 1" 8 11 SS impeller shim 1 30 Discharge gasket 4" 1 12 O-ring, pump housing 1 31 Discharge elbow 4" 1 13 Impeller 4" T CI 1 32 O-ring, 2 14 Volute 4" T CI 1 33 Male hose barb 4" 2 15 Volute gasket 4" 1 34 Hose nut 4" 2 16 Pump housing 4" 1 35 Suction strainer 4" 1 17 Bolt 3/8"-16 x 2" 8 36 Nut 4 18 O-ring, drain/filler plug 2 37 Bolt 4 19 Drain/filler plug 3/4" 2 38 Roll cage assembly L 1 Owner s Manual 17

WANCO INC. 5870 Tennyson Street Arvada, Colorado 80003 800-972-0755 303-427-5700 303-427-5725 fax www.voltmaster.com 2011 Wanco Inc. All rights reserved. Printed in the USA. 204229 Rev. A