27Overload Relays. Overview Combinations of overload relays and contactors SIRIUS 3R. Thermally delayed overload relays CLASS 10

Similar documents
SIRIUS 3RU2 Thermal Overload Relays

Protection Equipment. Overload Relays. Reference Manual 04/2011. Industrial Controls. Answers for industry.

Overload Relays. SIRIUS 3RU2 Thermal Overload Relays 3RU2 up to 40 A for standard applications. 5/78 Siemens IC Overview

Protection Equipment

Protection Equipment. 5/2 Introduction

3RT14 Contactors with 3 Main Contacts

IEC CONTACTORS. Contacts Model List Model List AC3 UL 115 V 230 V 200 V 230 V 460 V 575 V NO NC Number Price Number Price 3RT101

SIRIUS Configuration

Siemens AG Price groups PG 14O, 41B, 41E, 41F, 41G, 41H, 41J, 42F, 42J

Industrial Controls. Load Feeder. Configuring SIRIUS Innovations Selection data for Fuseless and Fused Load Feeders. Configuration Manual 04/2011

3NP1 Fuse Switch Disconnectors up to 630 A

BETA Switching Switches and Light Indicators

Siemens AG RW BB14 3RW BB14 3RW BB14. per PU three-phase induction opera- Rated Rated power of three-phase

DEVICE STATE/BYPASSED FAILURE OVERLOAD

SIRIUS 3RV2 Motor Starter Protectors/Circuit Breakers up to 40 A Accessories Enclosures and front plates

For Operation in the Control Cabinet 3RW Soft Starters

3VU13, 3VU16 Circuit-Breakers

Motor Starter Protectors

AF09... AF30 3-pole Contactors up to 25 HP / 600 VAC

For Operation in the Control Cabinet

3RW Soft Starters. General data. 6/4 Siemens LV

Technical specifications

IEC Power Control SIRIUS. Motor Starter Protectors. Revised 04/20/15. Section Overview... 1/2-1/3. Motor Starter Protectors

Short form catalogue. Motor protection & control

Motor Starter Protectors

For Operation in the Control Cabinet

Stars or starlets? Competitor overview switching devices. Only for internal use. sirius IN COMPARISON

3RW Soft Starters. General data. 6/4 Siemens LV 1 T 2006

4 - Miniature controls

Industrial Controls. Load Feeders. Configuring the SIRIUS Modular System Selection data for Fuseless and Fused Load Feeders. Configuration Manual

I r A short-circuit protective device: Observe the maximum permissible fuse of the contactor with direct device mounting.

SENTRON 3NP1 Fuse Switch Disconnectors up to 630 A

General technical data: CONTACTOR, AC-3, 11KW/400V, 1NO+1NC, AC110V 50HZ, 120V 60HZ 3-POLE, SZ S0 SCREW TERMINAL. product brand name

AF09... AF30 3-pole Contactors up to 20 HP / 480 VAC

3VF3 to 3VF8 Circuit-Breakers

06/001. Overload Relays, Motor-Protective Relays Overview. Overload / Motor-Protective Relays. Moeller HPL /2002

Protective Devices: Circuit-Breakers 1 )

Thermal overload relay TF65 and TF96

General technical data: CONTACTOR, AC-3, 5.5KW/400V, 1NC, AC110V 50HZ, 120V 60HZ 3-POLE, SZ S00 SCREW TERMINAL. product brand name

3RW Soft Starters. General data. 6/4 Siemens LV 1 T 2008

General technical data: CONTACTOR, AC-3, 18.5KW/400V, 1NO+1NC, DC 24V, 3-POLE, SZ S0 SCREW TERMINAL. product brand name

AF09... AF38 4-pole Contactors AC / DC Operated - with Screw Terminals

AF40... AF96 3-pole contactors Technical data

Bimetal Overload Relays 3UA and 3UC

Page. Circuit-Breakers M4 2 for motor protection. Auxiliary contacts 3 Signalling switch Auxiliary releases

DATASHEET - ZB Delivery program. Overload relay, 50-65A, 1N/O+1N/C. Catalog No Eaton Catalog No. XTOB065DC1 EL-Nummer

SIRIUS Innovations. Technical information for ring terminals SIRIUS. Answers for industry.

Approved Standards. Ordering Information. Thermal Overload Relay J7TKN. Model Number Legend. Thermal Overload Relay. Accessories

CA Z-EN Overload relays, CT-operated overload relays

AF40... AF96 3-pole contactors 30 to 60 hp at 480 V AC AC / DC operated with 1 N.O. + 1 N.C. auxiliary contacts

General technical data: CONTACTOR, AC-3, 4KW/400V, 2NO+2NC, DC 24V, 3-POLE, SZ S0 SCREW TERMINAL REMOVABLE AUX. SWITCH. product brand name

Item Code Description Quantity 3NA LV HRC FUSE LINK S00 80A 690AC 250DC 30 3NA3832 LV HRC FUSE LINK GL/GG S00 125A 500VAC 250VDC 0

Circuit-Breakers M4 166 for motor protection. Auxiliary contacts 167 Signalling switch Auxiliary releases

Index. Manual Motor Starters 1. Auxiliary Contact Blocks 1. Trip Alarm Auxiliary 1. Switch. Shunt Release 1. Under-voltage Release 2.

DATASHEET - DILMC9-10(24VDC) Technical data General. Contactor, 3p+1N/O, 4kW/400V/AC3. Catalog No Eaton Catalog No. XTCEC009B10TD.

Electronic overload relay EF65, EF96 and EF146

Switch Disconnectors. SENTRON 3NP5 Fuse Switch Disconnectors up to 630 A. Introduction. 7/106 Siemens LV

BETA Switching Switching Devices

Manual Motor Starters. Meta-MEC

Application Mini Contactors for Motors and Resistive Loads

Thermal overload relay TF140DU and TF140DU-V1000

3RG4 BERO Inductive Proximity Switches

Low-Voltage Controls and Distribution

Electronic overload relays EF205 and EF370

Order No. of the options EMC filter Class A

CI-TI Contactors and motor starters Types CI 61 - CI 98

3RV1011-0DA15 CIRCUIT-BREAKER, SIZE S00,

Technical data for manual motor starters Type MS325

AF / AF12Z pole Contactors AC / DC Operated - with Screw Terminals

Thermal overload relays Type TA Class 10

AE 9... AE 40 Contactors NE... Contactor Relays

Data sheet. CI-TI TM Contactors and Motor Starters Circuit Breakers CTI B1427

Siemens AG Switch Disconnectors SENTRON. Configuration. Edition 10/2015. Manual. siemens.com/lowvoltage

GV2, GV3, and GV7 Manual Motor Starters, Controllers, and Protectors Standard Features

Bulletin 193-T1 Bimetallic Overload Relays

Star Series Motor protection & control

Description. Positive safety relays

LR9 F OVERLOAD RELAYS

3 - Protection components Motor circuit-breakers

Control Circuit Protection

Controls. THERMAL OVERLOAD RELAYS RW..D (up to 40A)

Thermal Overload Relays - WEG RW Series, 2 Pole

Contactor Types CI 61-98

3RW Soft Starters. General data. 6/2 Siemens LV 1 N SIRIUS Soft Starters 01/2008. Siemens AG 2008

Air Circuit Breakers

General technical data. Ambient conditions

BETA Fuses and Fuse Systems

Bulletin 825 SMM Smart Motor Manager

Air Circuit Breakers

MS /27/2015. ABB contact for United States of America. General Information Extended Product Type: Categories

ASL09..S 3-pole Contactors - Spring Terminals

Siemens AG 2007 July 2007 V 1 N s L w alog Ne Cat sirius Soft Starters 3RW40 for standard applications

Position and Safety Switches

CI-TI Contactors and Motor Starters Type CI 6-50

Product range Overload relay ZB up to 150 A. Phase-failure sensitivity IEC/EN 60947, VDE 0660 Part 102

Partnership that you can trust. LV Switchgear Motor Control Products.

Deliveryprogramme. Overloadrelay,6-9A,1N/O+1N/C. Articleno CatalogNo. XTOM009AC1. Settingrange. Auxiliarycontacts. Short-circuitprotection

Characteristics TeSys contactors 0 TeSys k contactors and reversing contactors

SENTRON Switching and Protection Devices Switch Disconnectors

NSL..S 4-pole / 8-pole Contactor Relays - Spring Terminals

Transcription:

27Overload Relays Overview Combinations of overload relays and contactors SIRIUS 3R 27Overload Relays Contactors Current range A 3RT10 1 Size S00 3/4/5.5 kw 3RT10 2 Size S0 5.5/7.5/11 kw 3RT10 3 Size S2 15/18.5/22 kw 3RT10 4 Size S3 30/37/45 kw Thermally delayed overload relays CLASS 10 3RU1116 0.1 to 12 3RU1126 1..8 to 25 3RU1136 5.5 to 50 3RU1146 18 to 100 Solid-state overload relays CLASS 10 and 20 3RB1016 0.1 to 12 3RB1026 0.1 to 25 1 ) 3RB1036 6 to 50 3RB1046 13 to 100 Thermally delayed overload relays CLASS 10 3UA60 55 to 135 3UA61 55 to 150 3UA62 55 to 205 3UA66 80 to 400 Solid-state overload relays from CLASS 5 to 30, selectable 3RB1246 0.25 to 100 4 ) 4 ) 4 ) 4 ) 3RB1253 50 to 205 3RB1257 125 to 500 3RB1262 200 to 820 Thermistor motor protection device 3RN10 PTCs - Type A Combination possible 4/2 Siemens NS K 2000

SIRIUS 3R 27Overload Relays Overview Combinations of overload relays and contactors 3TF50/51 Size 6 55/75 kw 3TF52/53 Size 8 90/110 kw 3TF54/55 Size 10 132/160 kw 3TF56/57 Size 12 200/250 kw 3TF68/69 Size 14 375/450 kw / / 2 ) 2 ) 3 ) 3 ) 3 ) / / 1) Tripping class, CLASS 20 from 3 to 25 A. 2) From setting range 135 to 180 A, installation as a single unit is required (heat dissipation). 3) Installation only possible as a single unit 4) 3RB12 with bar-type transformer, installation only possible as a single unit. Siemens NS K 2000 4/3

3RU11 Thermally Delayed Overload Relays up to 100 A CLASS 10 SIRIUS 3R Selection and ordering data 3RU11 Thermally Delayed Overload Relays Screw or Cage Clamp connection 1 ), for mounting onto contactor or for installing as a single unit with adapter (adapter for installing as a single unit see Accessories) 3RU11 overload relays with screw or Cage Clamp connection (for auxiliary conductors) Auxiliary contacts 1 NO + 1 NC Manual/automatic RESET Switch position indicator For 3RT1 contactor or soft starter 3RW3 Size 2 ) Output of 4-pole 3-phase motors Current setting range Fuse 3 ) gl/gg STOP button Test function Phase failure sensitivity Integrated sealable cover CLASS 10 Overload relays with screw connection Overload relays with Cage Clamp connection Order No. Price Order No. Price Weight approx at AC 50 Hz 400 V P n kw A A } Preferred type 1 unit 1 unit kg Size S00 with terminal for contactor coil and auxiliary contact 3RU11 16-..B0 S00 0.11 to 0.16 0.5 } 3RU11 16-0AB0 - - 0..12 0.14 to 0.2 1 } 3RU11 16-0BB0 - - 0.06 0.18 to 0.25 1 } 3RU11 16-0CB0 - - 0.09 0.22 to 0.32 1.6 } 3RU11 16-0DB0 - - 0.28 to 0.4 2 } 3RU11 16-0EB0 - - 0.12 0.12 0.35 to 0.5 2 } 3RU11 16-0FB0 - - 0.18 0.45 to 0.63 2 } 3RU11 16-0GB0 - - 0.55 to 0.8 4 } 3RU11 16-0HB0 - - 0.25 0.7 to 1 4 } 3RU11 16-0JB0 - - 0.12 0.37 0.9 to 1.25 4 } 3RU11 16-0KB0 - - 0.55 1.1 to 1.6 6 } 3RU11 16-1AB0 - - 1.4 to 2 6 } 3RU11 16-1BB0 - - 0.75 1.8 to 2.5 10 } 3RU11 16-1CB0 - - 0.12 1.1 2.2 to 3.2 10 } 3RU11 16-1DB0 - - 1.5 2.8 to 4 16 } 3RU11 16-1EB0 - - 3.5 to 5 20 } 3RU11 16-1FB0 - - 2.2 4.5 to 6.3 20 } 3RU11 16-1GB0 - - 0.12 3 5.5 toto 8 25 } 3RU11 16-1HB0 - - 4 7 to 10 35 } 3RU11 16-1JB0 - - 5.5 9 to 12 35 } 3RU11 16-1KB0 - - Size S0 3RU11 26-..D0 S0 0.75 1.8 to 2.5 10 } 3RU11 26-1CB0 3RU11 26-1CD0 0.16 1.1 2.2 to 3.2 10 } 3RU11 26-1DB0 3RU11 26-1DD0 1.5 2.8 to 4 16 } 3RU11 26-1EB0 3RU11 26-1ED0 3.5 to 5 20 } 3RU11 26-1FB0 3RU11 26-1FD0 2.2 4.5 to 6.3 20 } 3RU11 26-1GB0 3RU11 26-1GD0 0.16 3 5.5 to 8 25 } 3RU11 26-1HB0 3RU11 26-1HD0 4 7 to 10 35 } 3RU11 26-1JB0 3RU11 26-1JD0 5.5 9 to 12.5 35 } 3RU11 26-1KB0 3RU11 26-1KD0 7.5 11 to 16 40 } 3RU11 26-4AB0 3RU11 26-4AD0 0.16 14 to 20 50 } 3RU11 26-4BB0 3RU11 26-4BD0 17 to 22 63 } 3RU11 26-4CB0 3RU11 26-4CD0 11 20 to 25 63 } 3RU11 26-4DB0 3RU11 26-4DD0 Size S2 3RU11 36-..B0 S2 3 5.5 to 8 25 } 3RU11 36-1HB0 3RU11 36-1HD0 0.3 4 7 to 10 35 } 3RU11 36-1JB0 3RU11 36-1JD0 5.5 9 to 12.5 35 } 3RU11 36-1KB0 3RU11 36-1KD0 Size S3 7.5 11 to 16 40 } 3RU11 36-4AB0 3RU11 36-4AD0 0.3 14 to 20 50 } 3RU11 36-4BB0 3RU11 36-4BD0 11 18 to 25 63 } 3RU11 36-4DB0 3RU11 36-4DD0 15 22 to 32 80 } 3RU11 36-4EB0 3RU11 36-4ED0 18.5 28 to 40 80 } 3RU11 36-4FB0 3RU11 36-4FD0 0.3 36 to 45 100 } 3RU11 36-4GB0 3RU11 36-4GD0 22 40 to 50 100 } 3RU11 36-4HB0 3RU11 36-4HD0 3RU11 46-..D0 S3 11 18 to 25 63 } 3RU11 46-4DB0 3RU11 46-4DD0 0.5 15 22 to 32 80 } 3RU11 46-4EB0 3RU11 46-4ED0 18.5 28 to 40 80 } 3RU11 46-4FB0 3RU11 46-4FD0 0.5 36 to 50 125 } 3RU11 46-4HB0 3RU11 46-4HD0 30 45 to 63 125 } 3RU11 46-4JB0 3RU11 46-4JD0 37 57 to 75 160 } 3RU11 46-4KB0 3RU11 46-4KD0 70 to 90 160 } 3RU11 46-4LB0 3RU11 46-4LD0 0.5 45 80 to 100 4 ) 200 } 3RU11 46-4MB0 3RU11 46-4MD0. 1) See page 6 for notes on Cage Clamp connection. 2) Consider the maximum rated operational current of contactors. 3) Max. fuse for overload relay only, type of coordination 2. Fuse values for mounting onto contactor see from page 4/10. 4) Thermally delayed overload relays > 100 A see page 4/31. 4/4 Siemens NS K 2000

SIRIUS 3R 3RU11 Thermally Delayed Overload Relays up to 100 A CLASS 10 Screw or Cage Clamp connection 1 ), for installing as a single unit 3RU11 overload relays with mounted adapter for installing as a single unit Screw and snap-on mounting onto 35 mm standard mounting rail Size S3 also for 75 mm standard mounting rail 3RU11 overload relays with screw or Cage Clamp connection (for auxiliary conductors) Auxiliary contacts 1 NO + 1 NC Manual/automatic RESET Switch position indicator For 3RT1 contactor or soft starter 3RW3 Size 2 ) Output of 4- pole 3-phase motors Current setting range Fuse 3 ) gl/gg Test function, STOP button Phase failure sensitivity Integrated sealable cover CLASS 10 Overload relays with screw connection Selection and ordering data Overload relays with Cage Clamp connection Order No. Price Order No. Price Weight approx. at 50 Hz 400 V AC P n kw A A } Preferred type 1 unit 1 unit kg Size S00 3RU11 16-..C1 S00 0.11 to 0.16 0.5 } 3RU11 16-0AB1 3RU11 16-0AC1 0.16 0.14 to 0.2 1 } 3RU11 16-0BB1 3RU11 16-0BC1 0.06 0.18 to 0.25 1 } 3RU11 16-0CB1 3RU11 16-0CC1 0.09 0.22 to 0.32 1.6 } 3RU11 16-0DB1 3RU11 16-0DC1 0.28 to 0.4 2 } 3RU11 16-0EB1 3RU11 16-0EC1 0.16 0.12 0.35 to 0.5 2 } 3RU11 16-0FB1 3RU11 16-0FC1 0.18 0.45 to 0.63 2 } 3RU11 16-0GB1 3RU11 16-0GC1 0.55 to 0.8 4 } 3RU11 16-0HB1 3RU11 16-0HC1 0.25 0.7 to 1 4 } 3RU11 16-0JB1 3RU11 16-0JC1 0.16 0.37 0.9 to 1.25 4 } 3RU11 16-0KB1 3RU11 16-0KC1 0.55 1.1 to 1.6 6 } 3RU11 16-1AB1 3RU11 16-1AC1 1.4 to 2 6 } 3RU11 16-1BB1 3RU11 16-1BC1 0.75 1.8 to 2.5 10 } 3RU11 16-1CB1 3RU11 16-1CC1 0.16 1.1 2.2 to 3.2 10 } 3RU11 16-1DB1 3RU11 16-1DC1 1.5 2.8 to 4 16 } 3RU11 16-1EB1 3RU11 16-1EC1 3.5 to 5 20 } 3RU11 16-1FB1 3RU11 16-1FC1 2.2 4.5 to 6.3 20 } 3RU11 16-1GB1 3RU11 16-1GC1 0.16 3 5.5 to 8 25 } 3RU11 16-1HB1 3RU11 16-1HC1 4 7 to 10 35 } 3RU11 16-1JB1 3RU11 16-1JC1 5.5 9 to 12 35 } 3RU11 16-1KB1 3RU11 16-1KC1 Size S0 3RU11 26-4.B1 S0 7.5 11 to 16 40 } 3RU11 26-4AB1-0.21 14 to 20 50 } 3RU11 26-4BB1-17 to 22 63 } 3RU11 26-4CB1-11 20 to 25 63 } 3RU11 26-4DB1 - Size S2 3RU11 36-4.B1 S2 15 22 to 32 80 } 3RU11 36-4EB1-0.45 18.5 28 to 40 80 } 3RU11 36-4FB1-36 to 45 100 } 3RU11 36-4GB1-22 40 to 50 100 } 3RU11 36-4HB1 - Size S3 3RU11 46-4.B1 S3 30 45 to 63 125 } 3RU11 46-4JB1-0.73 37 57 to 75 160 } 3RU11 46-4KB1-70 to 90 160 } 3RU11 46-4LB1-45 80 to 100 4 ) 200 } 3RU11 46-4MB1-1) See page 6 for notes on Cage Clamp connection. 2) Consider the maximum rated operational current of contactors. 3) Max. fuse for overload relay only, type of coordination 2. Fuse values for mounting onto contactor see from page 4/10. 4) Thermally delayed overload relays > 100 A see page 4/31. Siemens NS K 2000 4/5

3RU11 Thermally Delayed Overload Relays up to 100 A CLASS 10 SIRIUS 3R Accessories Design For type Order No. Price Weight approx. Pack. Size 1 unit kg unit Adapter for installing as a single unit 3RU19.6-3AA01 For separate mounting of overload relays, S00 3RU19 16-3AA01 0.04 1 Screw and snap-on mounting onto S0 3RU19 26-3AA01 0.06 35 mm standard mounting rail S2 3RU19 36-3AA01 0.15 Size S3 also for 75 mm standard mounting rail S3 3RU19 46-3AA01 0.23 Mechanical RESET 3RU19 00-1A Resetting plunger, holder and funnel S00 to S3 3RU19 00-1A 0.02 1 set Suitable pushbutton IP 65 22 mm 3SB10 00-0AH01 0.01 10 Holder for pushbutton 3SB19 02-1AC 0.02 100 Indicator label with inscription RESET 3SB19 01-4EM 20 with pushbutton, holder and indicator label Cable release with support for RESET 3RU19 00-1. (a bore of 6.5 mm dia. is required Length 400 mm S00 to S3 3RU19 00-1B 0.07 1 set in the switchboard, Length 600 mm 3RU19 00-1C max. switchboard thickness 8 mm) Module for remote RESET, electrical 3RU19 00-2A.71 Operating range 0.85 to 1.1 x U s S00 to S3 Power consumption AC 120 VA, DC 70 W ON period 0.2 s to 4 s AC/DC 24 V to 30 V 3RU19 00-2AB71 0.06 1 AC/DC 110 V to 127 V 3RU19 00-2AF71 AC/DC 220 V to 250 V 3RU19 00-2AM71 Cover Cover for cable lug and busbar connection S3 3RT19 46-4EA1 1 Cover for box terminals S2 3RT19 36-4EA2 1 S3 3RT19 46-4EA2 1 4/6 Siemens NS K 2000

SIRIUS 3R 3RU11 Thermally Delayed Overload Relays up to 100 A CLASS 10 Technical data according to IEC 60 947-4-1 and IEC 60 947-5-1 Type 3RU11 16-... 3RU11 26-... 3RU11 36-... 3RU11 46-... Size S00 S0 S2 S3 Trip class acc. to IEC 60 947-4-1 CLASS 10 Phase failure sensitivity yes Increased safety EEx e KEMA test certificate No.EX-97.Y.3235 DMT 98 ATEX G001 Adjustable to automatic reset yes RESET button with trip-free feature yes Permissible ambient temperature (above +60 C current reduction) Storage/transport C 55 to +80 operation C 20 to +70 Permissible rated current at temperature inside cubicle 60 C % 100 temperature inside cubicle 70 C % 87 Temperature compensation C up to 60 Switch position indicator yes Test function yes STOP button yes Terminal for contactor coil yes not required Terminal for contactor coil auxiliary contacts yes not required Degree of protection acc. to IEC 60 529/DIN VDE 0470 Part 1 IP 20 IP 20 1 ) Shock-hazard protection acc. to DIN VDE 0106 Part 100 Safe from finger touch Shock resistance with sine acc. to IEC 60 068 Part 2-27 g/ms 8/10 Main circuit Rated insulation voltage U i (pollution degree 3) V 690 1000 Rated impulse withstand voltage U imp kv 6 8 Type of current DC, AC Current setting A 0.11 0.16 up to 9 12 1.8 2.5 up to 20 25 5..5 8 up to 40 50 18 25 up to 80 100 Power losses per unit (max.) W 3.9 to 6.6 3.9 to 6 6 to 9 10 to 16.5 Short-circuit protection with fuses overload relays alone together with contactor 2 ) ) Conductor cross-section main circuit Type of connection Screw connection Box terminal Terminal screw Pozidriv size 2 Pozidriv size 2 4 mm Allen screw Conductor cross-sections solid mm 2 2 x (0.5 to 1..5) 2 x (1 to 2.5) 2 x (0.75 to 16) 2 x (2.5 to 16) mm 2 2 x(0.75 to 2.5) 2 x (2.5 to 6) stranded mm 2 2 x (0.5 to 1.5) 2 x (1 to 2.5) 2 x (0.75 to 25) 2 x (10 to 50) 2 mm 2 x(0.75 to 2.5) 2 x (2.5 to 6) 1 x (0.75 to 35) 1 x (10 to 70) finely stranded with end sleeve mm 2 2 x (0.5 to 1.5) 2 x (1 to 2.5) 2 x (0.75 to 16) 2 x (2.5 to 35) mm 2 2 x(0.75 to 2.5) 2 x (2.5 to 6) 1 x (0.75 to 25) 1 x (2.5 to 50) AWG conductor connections AWG 2 x (18 to 14) 2 x (14 to 10) 2 x (18 to 3) 2 x (10 to 1/0) solid or stranded AWG 1 x (18 to 2) 2 x (10 to 2/0) Removable box terminal busbar connection mm 18 x 10 with cable lug connection mm 2 to 2 x 70 1) Terminal department: degree of protection IP 00. 2) See selection and ordering data from page 4/4. 3) See page 4/10 and page 4/11. Siemens NS K 2000 4/7

3RU11 Thermally Delayed Overload Relays up to 100 A CLASS 10 Technical data according to IEC 60 947-4-1 and IEC 60 947-5-1 SIRIUS 3R Type 3RU11 16-... 3RU11 26-... 3RU11 36-... 3RU11 46-... Size S00 S0 S2 S3 Auxiliary circuit Auxiliary contacts 1 NO + 1 NC Contact rating NC at AC, AC-14/AC-15 Rated operational current I e at U e : 24 V A 4 230 V A 3 400 V A 1.5 600 A 0.6 NO at AC, AC-14/AC-15 Rated operational current I e at U e : 24 V A 3 230 V A 2 400 V A 1 600 A 0.6 NC, NO at DC, DC-13 Rated operational current I e at U e : 24 V A 1 110 V A 0,15 220 V A 0.1 Conventional thermal current I th A 6 Contact reliability yes (suitability for PLC control; 17 V, 5 ma) Short-circuit protection Fuse links Utilization category gl/gg A 6 fast A 10 Miniature circuit-breakers, C-characteristics A 6 1 ) Rated insulation voltage U i (pollution degree 3) V 690 Rated impulse withstand voltage U imp kv 6 Conductor cross-sections of auxiliary circuit Type of connection Screw connection Cage Clamp connection 2 ) Terminal screw Pozidriv size 2 Min./max. conductor cross-sections solid mm 2 2 x (0.5 to 1.5)/ 2 x (0.75 to 2.5) 2 x (0.5 to 2.5) stranded mm 2 2 x (0.5 to 1.5)/ 2 x (0.75 to 2.5) 2 x (0.5 to 2.5) finely stranded with end sleeve mm 2 2 x (0.5 to 1.5)/ 2 x (0.75 to 2.5) 2 x (0.5 to 1.5) AWG cond. connect., solid or stranded AWG 2 x (18 to 14) 2 x (18 to 14) Adapter for installing as a single unit for screw and snap-on mounting onto 35 mm standard mounting rail, Size S3 also for 75 mm standard mounting rail Type 3RU19 16-3AA01 3RU19 26-3AA01 3RU19 36-3AA01 3RU19 46-3AA01 For overload relays 3RU11 16-... 3RU11 26-... 3RU11 36-... 3RU11 46-... Conductor cross-sections of main circuit Type of connection Screw connection Box terminal Terminal screw Pozidriv size 2 Pozidriv size 2 Pozidriv size 2 4 mm Allen screw Minimum/maximum conductor cross-sections finely stranded with end 1 concuctor mm 2 0.5 to 2.5 1 to 6 0.75 to 25 2.5 to 50 sleeve solid or stranded 1 conductor mm 2 0.5 to 4 3 ) 1 to 6 0.75 to 35 2.5 to 70 AWG conductor connections, solid or stranded 1 x AWG 18 to 14 14 to 10 18 to 2 10 to 1/0 s-, u-, U-Ratings Auxiliary circuit Switching capacity B600. R300 1) Up to I K 0.5 ka; 260 V. 2) See page 6 for notes on Cage Clamp connection. 3) Not acc. to IEC. 4/8 Siemens NS K 2000

SIRIUS 3R 3RU11 Thermally Delayed Overload Relays up to 100 A CLASS 10 Selection guide Contactor assemblies for star-delta starting Rated motor Current setting range Overload relay Line and Star contactor Wiring current (The overload relays must be set to 0.58 times the rated motor current) delta contactor assembly kit A A Type Type Type Type Size S00 1.9 to 2.8 2.4 to 3.4 3.1 to 4.3 1.1 to 1.6 1.4 to 2 1.8 to 2.5 3RU11 16-1AB0 3RU11 16-1BB0 3RU11 16-1CB0 3RT10 15 3RT10 15 3RT10 15 3RT10 15 3RT10 15 3RT10 15 3RA19 13-2B 3RA19 13-2B 3RA19 13-2B 3.8 to 5.5 4.8 to 6.9 6 to 8.6 7.8 to 10.9 2.2 to 3.2 2.8 to 4 3.5 to 5 4.5 to 6.3 3RU11 16-1DB0 3RU11 16-1EB0 3RU11 16-1FB0 3RU11 16-1GB0 3RT10 15 3RT10 15 3RT10 15 3RT10 15 3RT10 15 3RT10 15 3RT10 15 3RT10 15 3RA19 13-2B 3RA19 13-2B 3RA19 13-2B 3RA19 13-2B 9.5 to 13.8 12.1 to 17.2 15.5 to 21 Size S0 3.1 to 4.3 3.8 to 5.5 4.8 to 6.9 5.5 to 8 7 to 10 9 to 12 1.8 to 2.5 2.2 to 3.2 2.8 to 4 3RU11 16-1HB0 3RU11 16-1JB0 3RU11 16-1KB0 3RU11 26-1CB0 3RU11 26-1DB0 3RU11 26-1EB0 3RT10 16 3RT10 17 3RT10 17 3RT10 24 3RT10 24 3RT10 24 3RT10 15 3RT10 15 3RT10 15 3RT10 24 3RT10 24 3RT10 24 3RA19 13-2B 3RA19 13-2B 3RA19 13-2B 3RA19 23-2B 3RA19 23-2B 3RA19 23-2B 6 to 8.6 7.8 to 10.9 9.5 to 13.8 3.5 to 5 4.5 to 6.3 5.5 to 8 3RU11 26-1FB0 3RU11 26-1GB0 3RU11 26-1HB0 3RT10 24 3RT10 24 3RT10 24 3RT10 24 3RT10 24 3RT10 24 3RA19 23-2B 3RA19 23-2B 3RA19 23-2B 12.1 to 17.2 15.5 to 21.5 19 to 27.6 7 to 10 9 to 12.5 11 to 16 3RU11 26-1JB0 3RU11 26-1KB0 3RU11 26-4AB0 3RT10 24 3RT10 24 3RT10 25 3RT10 24 3RT10 24 3RT10 24 3RA19 23-2B 3RA19 23-2B 3RA19 23-2B 24.1 to 34 29.3 to 37.9 34.5 to 43 Size S2 9.5 to 13.8 12.1 to 17.2 15.5 to 21.5 14 to 20 17 to 22 20 to 25 5.5 to 8 7 to 10 9 to 12.5 3RU11 26-4BB0 3RU11 26-4CB0 3RU11 26-4DB0 3RU11 36-1HB0 3RU11 36-1JB0 3RU11 36-1KB0 3RT10 26 3RT10 26 3RT10 26 3RT10 34 3RT10 34 3RT10 34 3RT10 25 3RT10 25 3RT10 25 3RT10 34 3RT10 34 3RT10 34 3RA19 23-2B 3RA19 23-2B 3RA19 23-2B 3RA19 33-2B 3RA19 33-2B 3RA19 33-2B 19 to 27.6 24.1 to 34 31 to 43 37.9 to 55.2 11 to 16 14 to 20 18 to 25 22 to 32 3RU11 36-4AB0 3RU11 36-4BB0 3RU11 36-4DB0 3RU11 36-4EB0 3RT10 34 3RT10 34 3RT10 34 3RT10 34 3RT10 34 3RT10 34 3RT10 34 3RT10 34 3RA19 33-2B 3RA19 33-2B 3RA19 33-2B 3RA19 33-2B 48.3 to 69 62.1 to 77.6 69 to 86.2 Size S3 31 to 43.1 37.9 to 55.2 48.3 to 69 28 to 40 36 to 45 40 to 50 18 to 25 22 to 32 28 to 40 3RU11 36-4FB0 3RU11 36-4GB0 3RU11 36-4HB0 3RU11 46-4DB0 3RU11 46-4EB0 3RU11 46-4FB0 3RT10 35 3RT10 36 3RT10 36 3RT10 44 3RT10 44 3RT10 44 3RT10 34 3RT10 34 3RT10 34 3RT10 44 3RT10 44 3RT10 44 3RA19 33-2B 3RA19 33-2B 3RA19 33-2B 3RA19 43-2B 3RA19 43-2B 3RA19 43-2B 62.1 to 77.6 6 to 108.6 36 to 45 45 to 63 3RU11 46-4HB0 3RU11 46-4JB0 3RT10 44 3RT10 44 3RT10 44 3RT10 44 3RA19 43-2B 3RA19 43-2B 98.3 to 129.3 120.7 to 155.2 137.9 to 172.4 57 to 75 70 to 90 80 to 100 3RU11 46-4KB0 3RU11 46-4LB0 3RU11 46-4MB0 3RT10 45 3RT10 46 3RT10 46 3RT10 44 3RT10 44 3RT10 44 3RA19 43-2B 3RA19 43-2B 3RA19 43-2B Siemens NS K 2000 4/9

3RU11 Thermally Delayed Overload Relays CLASS 10 SIRIUS 3R Technical data Short-circuit protection with fuses for motor feeders with short-circuit currents up to 70 ka at AC 50/60 Hz 690 V Permissible short-circuit fuses for motor starters comprising overload relay and contactor, type of coordination 2 Size S00 ULfuse Circuit-breaker for Current setting range 3 kw 3RT10 15 4 kw 3RT10 16 5.5 kw 3RT10 17 starter protection at I e max = 7 A (at AC 50 Hz 400 V) I e max = 9 A (at AC 50 Hz 400 V) I e max = 12 A (at AC 50 Hz 400 V) RK5 I q = 50 ka / AC 400 V A gl/gg am BS88T gl/gg am BS88T gl/gg am BS88T A 0.11 to 0.16 0.5 0.5 0.5 1 0.14 to 0.2 1 1 1 1 3RV1321-0BC10 0.18 to 0.25 1 1 1 1 3RV1321-0CC10 0.22 to 0.32 1.6 2 1.6 2 1.6 2 1 3RV1321-0DC10 0.28 to 0.4 2 2 2 2 2 2 1.6 3RV1321-0EC10 0.35 to 0.5 2 2 2 2 2 2 2 3RV1321-0FC10 0.45 to 0.63 2 4 2 4 2 4 2.5 3RV1321-0GC10 0.55 to 0.8 4 4 4 4 4 4 3 3RV1321-0HC10 0.7 to 1 4 6 4 6 4 6 4 3RV1321-0JC10 0.9 to 1.25 4 6 4 6 4 6 5 3RV1321-0KC10 1.1 to 1.6 6 10 6 10 6 10 6 3RV1321-1AC10 1.4 to 2 6 10 6 10 6 10 8 3RV1321-1BC10 1.8 to 2.5 10 10 10 10 10 10 10 2.2 to 3.2 10 16 10 16 10 16 12 2.8 to 4 16 16 16 16 16 16 16 3.5 to 5 20 6 20 20 6 20 20 6 20 20 4.5 to 6.3 20 6 20 20 6 20 20 6 20 25 5.5 to 8 20 10 20 20 10 20 20 10 20 30 7 to 10 20 16 20 20 16 20 40 9 to 12 20 16 20 45 Size S0 ULfuse Circuit-breaker for Current setting range 5.5 kw 3RT10 24 7.5 kw 3RT10 25 11 kw 3RT10 26 starter protection at I e max = 12 A (at AC 50 Hz 400 V) I e max = 17 A (at AC 50 Hz 400 V) I e max = 25 A (at AC 50 Hz 400 V) RK5 I q = 50 ka / AC 400 V A gl/gg am BS88T gl/gg am BS88T gl/gg am BS88T A 1.8 to 2.5 10 10 10 10 10 10 10 3RV1321-1CC10 2.2 to 3.2 10 16 10 16 10 16 12 3RV1321-1DC10 2.8 to 4 16 16 16 16 16 16 16 3RV1321-1EC10 3.5 to 5 20 6 20 20 6 20 20 6 20 20 3RV1321-1FC10 4.5 to 6.3 20 6 25 20 6 25 20 6 25 25 3RV1321-1GC10 5.5 to 8 25 10 25 25 10 25 25 10 25 30 3RV1321-1HC10 7 to 10 25 16 25 25 16 25 32 16 35 40 3RV1321-1JC10 9 to 12.5 25 20 25 25 20 25 35 20 35 45 3RV1321-1KC10 11 to 16 25 20 25 25 20 25 35 20 35 60 3RV1321-4AC10 14 to 20 25 20 25 35 20 35 80 3RV1321-4BC10 17 to 22 35 20 35 80 3RV1321-4CC10 20 to 25 35 20 35 100 Type of coordination 1 see short-circuit protection of contactors, Part 3. 4/10 Siemens NS K 2000

SIRIUS 3R 3RU11 Thermally Delayed Overload Relays CLASS 10 Technical data Short-circuit protection with fuses for motor feeders with short-circuit currents up to 70 ka at AC 50/60 Hz 690 V Permissible short-circuit fuses for motor starters comprising overload relays and contactor, type of coordination 2 Size S2 ULfuse Circuit-breaker for Current setting range 15 kw 3RT10 34 18.5 kw 3RT10 35 22 kw 3RT10 36 starter protection at I e max = 32 A (at AC 50 Hz 400 V) I e max = 40 A (at AC 50 Hz 400 V) I e max = 50 A (at AC 50 Hz 400 V) RK5 I q = 50 ka / AC 400 V A gl/gg am BS88T gl/gg am BS88T gl/gg am BS88T A 5.5 to 8 25 10 25 25 10 25 25 10 25 30 7 to 10 32 16 32 32 16 32 32 16 32 40 9 to 12.5 35 16 35 35 16 35 35 16 35 50 11 to 16 40 20 40 40 20 40 40 20 40 60 14 to 20 50 25 50 50 25 50 50 25 50 80 18 to 25 63 32 63 63 32 63 63 32 63 100 3RV1331-4DC10 22 to 32 63 35 63 63 35 63 80 35 80 125 3RV1331-4EC10 28 to 40 63 50 63 63 50 63 80 50 80 150 3RV1331-4FC10 36 to 45 63 50 63 80 50 80 175 3RV1331-4GC10 40 to 50 80 50 80 200 3RV1331-4HC10 Size S3 UL-fuse Circuit-breaker for Current setting range 30 kw 3RT10 44 37 kw 3RT10 45 45 kw 3RT10 46 RK5 starter protection at I e max = 65 A (at AC 50 Hz 400 V) I e max = 80 A (at AC 50 Hz 400 V) I e max = 95 A (at AC 50 Hz 400 V) I q = 50 ka/ AC 400 V A gl/gg am BS88T gl/gg am BS88T gl/gg am BS88T A 18 to 25 63 32 63 63 32 63 63 32 63 100 22 to 32 80 35 80 80 35 80 80 35 80 125 28 to 40 80 50 80 80 50 80 80 50 80 150 36 to 50 125 50 125 125 50 125 125 50 125 200 45 to 63 125 63 125 160 63 160 160 63 160 250 3RV1341-4JC10 57 to 75 160 80 160 160 80 160 300 3RV1341-4KC10 70 to 90 160 100 160 350 3RV1341-4LC10 80 to 100 160 100 160 350 3RV1341-4MC10 Type of coordination 1 see short-circuit protection of contactors, Part 3. Siemens NS K 2000 4/11

3RU11 Thermally Delayed Overload Relays CLASS 10 SIRIUS 3R Description Specifications Overload relays 3RU11 IEC 60 947-4-1, IEC 60 947-5-1 and DIN VDE 0660. The 3RU11 overload relays are suitable for use in any climate. a The devices are shock-hazardprotected acc. to DIN VDE 0106 Part 100. s d General 3RU11 overload relays belong to the new generation of SIRIUS 3R switching devices. They are available in four different sizes with up to 100 A. The 3RU11 overload relays replace the highly successful 3UA5 and 3UA7 devices. Outstanding features of the new relays include long-term stability and a long service life.the overload relays are optimally matched, both electrically and mechanically, to the 3RT10 contactors and 3RW3 soft starter. They can, however, also be mounted separately with an adapter for installation as a single unit. Devices up to and including size S0 can be fitted on standard mounting rails without using tools. 3RU11 overload relays cannot be mounted on 3TF contactors. Environment The devices are manufactured using environmentally-compatible and recyclable materials only. Application 3RU11 thermal overload relays provide overload protection for three-phase induction motors with rated currents of up to 100 A (45 kw, AC-3, 400 V). Fuses or 3RV13 circuit-breakers for starter combinations (see Part 1) must be fitted for shortcircuit protection. Operation of frequency converters The thermal overload relays 3RU11 are suitable for operation on frequency converters. f Ambient conditions Thanks to the new bimetals used and continuous temperature compensation, the devices can be implemented without restrictions at an ambient temperature of up to 60 C. Auxiliary contacts The overload relays are equipped with an NC contact for disconnecting the contactor and an NO contact for signalling tripping. The breaking capacity of the switching contacts is very high so that the contactor coils can be switched directly. Trip class The relays are designed in accordance with trip class 10, i. e. they can be used for motor start-up times of up to 10 s. Phase failure sensitivity A phase failure sensitivity function is integrated in order to provide overload protection in the event of a phase failure, i. e. premature tripping with doublephasing. Setting the overload relay The current setting screw can be accessed once the transparent, sealable cover has been removed. The overload relay must be set to the rated motor current. STOP funktion Activating this function only affects the NC contact. g h j k l Manual/automatic reset Manual or automatic reset can be selected with the blue button. The appropriate setting is selected by pressing and turning the button and can be sealed. Test function and switch position indicator The switch position indicator also incorporates a test function which, when activated, simulates a tripped overload relay. Both auxiliary contacts are actuated and the switch positon is indicated. Terminal for contactor coil and auxiliary contact When the 3RU11 16 overload relays (size S00) are mounted directly on the contactor, the auxiliary contact and coil terminals A2 of the contactor are fed through which considerably facilitates wiring. This is not necessary with sizes S0 to S3 as the contactors are equipped with 4 coil terminals. Cage Clamp connection 1 ) As of now, 3RU11 overload relays are available with Cage Clamp terminals. S00 relays are fitted with Cage Clamp terminals on the main and auxiliary contacts and relay sizes S0 to S3 on the auxiliary contacts. a Equipment identifying marker s Manual/automatic RESET selector switch d STOP button f Complete Order No. on front of device g Switch position indicator and TEST function h Transparent cover, sealable, secures the current setting screw, Test function and manual/automatic RESETposition j Current setting screw k Terminal for contactor coil (when mounted on contactor) l Terminal for auxiliary contacts (when mounted on contactor) Accessories The accessories available are suitable for use with all sizes. Electrical remote RESET with different voltage variants. Mechanical remote RESET comprising a tappet, funnel and holder for actuating the switchgear cabinet door with a 3SB1 pushbutton. Cable release for RESET for devices which are not easily accessible. Overload protection of flameproof motors of protection types increased safety EEx e EN 50 019/DIN VDE 0165, DIN VDE 0170/0171. KEMA test certificate No. Ex-97.Y.3235 DMT 98 ATEX G001 EN 50 019: 1977 + A1... A5, increased safety e : Appendix A, guidelines for temperature monitoring squirrel - cage motors in operation. 1) See page 6 for notes on Cage Clamp connection. 4/12 Siemens NS K 2000

SIRIUS 3R 3RU11 Thermally Delayed Overload Relays CLASS 10 Description Tripping characteristics The current-time curves show the relatonship between the tripping time from cold state and multiples of the set current I e. When the relay is at operating temperature and carrying 1.0 I e, the tripping times are reduced to approximately 25 %. For single-pole loads the tripping curves lie between the curves shown. For normal operation, all 3 bimetallic strips of the overload relay must be heated. The 3RU11 overload relays are suitable for protecting motors with phase control. For protecting single-phase or DC-loads, all three main conducting paths must be connected in series. The release current with a 3-pole symmetrical load is between 105 % and 120 % of the set current. Trip classes of thermal, delayed magnetic or solid-state overload relays excerpt from IEC 60 947-4-1 CLASS Tripping time t A in seconds at 7.2 x I e from cold state 10 A 2 < t A 10 10 4 < t A 10 20 6 < t A 20 30 9 < t A 30 Typical time-current characteristic Protection of DC motors Internal circuit diagrams Single-pole 2-pole 3RU11 16 overload relays 3RU11 2 to 3RU11 4 overload relays Siemens NS K 2000 4/13

3RB10 Solid-State Overload Relays up to 100 A CLASS 10 and CLASS 20 SIRIUS 3R Selection and ordering data 3RB10 Solid-State Overload Relays Screw connection, for mounting onto contactors or for installing as a single unit with adapter (adapter for installing as a single unit see Accessories) 3RB10 overload relays with Self-supply Auxiliary contacts 1 NO + 1 NC Manual/automatic RESET Switch position indicator For contactor or soft starter Size 1 ) Output of 4-pole 3-phase motors at AC 50 Hz 400 V P n kw Current setting range Fuse 2 ) gl/gg A A Test function, STOP button Phase failure/asymmetry sensitivity CLASS 10 Overload relays Order No. Price } Preferred type 1 unit kg CLASS 10, size S00 with terminal for contactor coil and auxiliary contacts S00 up to 0.09 0.1 to 0.4 2 } 3RB10 16-1RB0 0.210 0.12 to 0.55 0.4 to 1.6 6 } 3RB10 16-1NB0 0.55 to 2.2 1.5 to 6 20 } 3RB10 16-1PB0 1.1 to 5.5 3 to 12 35 } 3RB10 16-1SB0 Weight approx. CLASS 10, size S0 S0 up to 0.09 0.1 to 0.4 2 } 3RB10 26-1RB0 0.225 0.12 to 0.55 0.4 to 1.6 6 } 3RB10 26-1NB0 0.55 to 2.2 1.6 to 6 25 } 3RB10 26-1PB0 1.1 to 5.5 3 to 12 35 } 3RB10 26-1SB0 3 to 11 6 to 25 63 } 3RB10 26-1QB0 CLASS 10, size S2 S2 3 to 11 6 to 25 63 } 3RB10 36-1QB0 7.5 to 22 13 to 50 100 } 3RB10 36-1UB0 CLASS 10, size S3 S3 7.5 to 22 13 to 50 125 } 3RB10 46-1UB0 11 to 45 25 to 100 200 } 3RB10 46-1EB0 Installation as a single unit 3RB10 with fitted adapter for installing as a single unit, for trip class CLASS 10 Size 1 ) Output of 4-pole 3-phase motors at AC 50 Hz 400 V P n kw Current setting range Fuse 2 ) gl/gg A A Overload relays Order No. Price } Preferred type 1 unit kg CLASS 10, width 45 mm S00 0.1 to 0.4 2 } 3RB10 16-1RB1 0.210 0.4 to 1.6 6 } 3RB10 16-1NB1 1.5 to 6 20 } 3RB10 16-1PB1 3 to 12 35 } 3RB10 16-1SB1 S 0 6 to 25 63 } 3RB10 26-1QB1 CLASS 10, width 55 mm S 2 13 to 50 100 } 3RB10 36-1UB1 CLASS 10, width 70 mm S 3 25 to 100 200 } 3RB10 46-1EB1 Weight approx. 1) Consider the maximum rated operational current of the units. 2) Thermally delayed overload relays > 100 A see page 4/19. 4/14 Siemens NS K 2000

SIRIUS 3R 3RB10 Solid-State Overload Relays up to 100 A CLASS 10 and CLASS 20 Selection and ordering data Screw connection, for mounting onto contactors or for installing as a single unit with adapter (adapter for installing as a single unit see Accessories) 3RB10 overload relays with Self-supply Auxiliary contacts 1 NO + 1 NC Manual/automatic RESET Switch position indicator For contactor or soft starter Size 1 ) Output of 4-pole 3-phase motors at AC 50 Hz 400 V P n kw Current setting range Fuse 2 ) gl/gg A A Test function, STOP button Phase failure/asymmetry sensitivity CLASS 20 Overload relays Order No. Price } Preferred type 1 unit kg CLASS 20, size S00 with terminal for contactor coil and auxiliary contact S00 up to 0.09 0.1 to 0.4 2 } 3RB10 16-2RB0 0.210 0.12 to 0.55 0.4 to 1.6 6 } 3RB10 16-2NB0 0.55 to 2.2 1.5 to 6.0 20 } 3RB10 16-2PB0 1.1 to 5.5 3 to 12 35 } 3RB10 16-2SB0 Weight approx. CLASS 20, size S0 S0 1.1 btois 5.5 3 to 12 35 } 3RB10 26-2SB0 0.225 3 to 11 6 to 25 63 } 3RB10 26-2QB0 CLASS 20, size S2 S2 3 to 11 6 to 25 63 } 3RB10 36-2QB0 7.5 to 22 13 to 50 100 } 3RB10 36-2UB0 CLASS 20, size S3 S3 7.5 to 22 13 to 50 125 } 3RB10 46-2UB0 11 to 45 25 to 100 200 } 3RB10 46-2EB0 1) Consider the maximum rated operational current of the units. 2) Thermally delayed overload relays > 100 A and see Page 4/19. Siemens NS K 2000 4/15

3RB10 Solid-State Overload Relays up to 100 A CLASS 10 and CLASS 20 SIRIUS 3R Accessories Design For type Order No. Price Weight approx. Pack. Size } Preferred type 1 unit kg unit Adapter for installing as a single unit 3RU19.6-3AA01 For separate mounting of overload relays, S00 } 3RU19 16-3AA01 0.04 1 screw and snap-on mounting onto S0 } 3RU19 26-3AA01 0.05 35 mm standard mounting rail S2 } 3RU19 36-3AA01 0.15 Size S3 also for 75 mm standard mounting rail S3 } 3RU19 46-3AA01 0.23 Mechanical RESET 3RU19 00-1A Resetting plunger, holder and funnel S0 to S3 } 3RU19 00-1A 0.02 1 set Suitable pushbutton IP 65 22 mm } 3SB10 00-0AH01 0.01 10 Holder for pushbutton } 3SB19 02-1AC 0.02 100 Indicator label with inscription RESET } 3SB19 01-4EM 20 with pushbutton, holder and indicator label Cable release with support for RESET 3RU19 00-1B, -1C A bore of 6.5 mm is required Length 400 mm in the switchboard For a max. switchboard thickness of 8 mm Length 600 mm S00 to S3 } 3RU19 00-1B 0.07 1 set } 3RU19 00-1C Module for remote RESET, electrical 3RU19 00-2A.71 Operating range 0.85 to 1.1 x U s Power consumption AC 120 VA, DC 70 W ON period 0.2 s to 2 s AC/DC 24 V to 30 V S00 to S3 } 3RU19 00-2AB71 0.06 1 AC/DC 110 V to 127 V } 3RU19 00-2AF71 AC/DC 220 V to 250 V } 3RU19 00-2AM71 Sealable cover, transparent For covering current-setting screw and for immobilization of the selector switch Manual/automatic RESET (bag of 10 covers) S00 to S3 } 3RB19 00-3B 1 bag 4/16 Siemens NS K 2000

SIRIUS 3R 3RB10 Solid-State Overload Relays up to 100 A CLASS 10 and CLASS 20 Technical data according to IEC 60 947-4-1 and IEC 60 947-5-1 Type 3RB10 16-3RB10 26-3RB10 36-3RB10 46- Size S00 S0 S2 S3 Trip class IEC 60.947-4-1 CLASS 10 and 20, depending on version Phase failure sensitivity Tripping from warm state s < 3 PTB Test Report (increased safety EEx e) 3.43-8803/98 Permissible ambient temperature storage/transport C 55 to +80 operation C 20 to +70 Adjustable to automatic reset yes Recovery time for automatic RESET min ca. 4 for manual RESET sofort Switch position indicator/test function yes RESET button yes STOP button yes Terminal for contactor coil yes not required Terminal for auxiliary contacts yes not required Degree of protection acc. to IEC 60 529/DIN VDE 0470 Part 1 IP 20 IP 20 1 ) Shock-hazard protection acc. to DIN VDE 0106 Part 100 Safe from finger touch Shock resistance with sine acc. toacc. to IEC 60 068 Part 2-27 g/ms 8/10 and 15 /11 Mounting position any EMC immunity Conducted interference injection Burst acc. to IEC 61 000-4-4: (corresponds to severity 3) kv 2 Conducted interference injection Surge acc. to IEC 61 000-4-5: (corresponds to severity 3) Electrostatic discharge acc. to IEC 61 000-4-2: (corresponds to severity 3) Field-generated interference injection acc. to IEC 61 000-4-3: (corresponds to severity 3) kv 2 kv 8 Resistance to extreme climates Humidity % 100 Main circuit V/m 6 10 2 ) 10 Rated insulation voltage U i (pollution degree 3) V 690 1000 Rated impulse withstand voltage U imp kv 6 8 Type of current AC Frequency range 50/60 Hz ± 3 Current setting A 0.1 0.4 to 3 12 Own power consumption W (VA) approx. 0.05 Short-circuit protection with fuses Overload relays alone 3 ) together with contactor 4 ) Conductor cross-sections for main circuit 0.1 0.4 to 6 25 6 25 to 13 50 13 50 to 25 100 Type of connection Screw connection Box terminal Terminal screw Pozidriv size 2 Pozidriv size 2 Pozidriv size 2 4mm Allen screw Conductor cross-sections solid mm 2 2 x (0.5 to 1.5) 2 x (1 to 2.5) 2 x (0.75 to 16) 2 x (2.5 to 16) mm 2 2 x (0.75 to2.5) 2 x (2.5 to 6) stranded mm 2 2 x (0.5 to 1.5) 2 x (1 to 2.5) 2 x (0.75 to 25) 2 x (10 to 50) mm 2 2 x(0.75 to 2.5) 2 x (2.5 to 6) 1 x (0.75 to 35) 1 x (10 to 70) finely stranded with end sleeve mm 2 2 x (0.5 to 1.5) 2 x (1 to 2.5) 2 x (0.75 to 16) 2 x (2.5 to 35) mm 2 2 x(0.75 to 2.5) 2 x (2.5 to 6) 1 x (0.75 to 25) 1 x (2.5 to 50) AWG conductor connections AWG 2 x (18 to 14) 2 x (14 to 10) 2 x (18 to 3) 2 x (10 to 1/0) solid or stranded AWG 1 x (18 to 2) 2 x (10 to 2/0) Removable box terminal Busbar connection mm 18 x 10 With cable lug connection mm 2 to 2 x 70 1) Connection area: degree of protection IP 00. 2) 3 V/m for current setting range 0.1 to 0.4 A. 3) See Selection and ordering data. 4) See table on page 4/19. Siemens NS K 2000 4/17

3RB10 Solid-State Overload Relays up to 100 A CLASS 10 and CLASS 20 Technical data according to IEC 60 947-4-1 and IEC 60 947-5-1 SIRIUS 3R Type 3RB10 16-3RB10 26-3RB10 36-3RB10 46- Size S00 S0 S2 S3 Auxiliary circuit Auxiliary contacts 1 NO + 1 NC Contact rating at AC-14/AC-15 Rated operational current I e at U e: 24 V A 4 125 V A 4 230 V A 3 400 V A 2 690 V A 1 at DC-13 Rated operational current I e at U e : 24 V A 1 110 V A 0.22 220 V A 0.1 Contact reliability Contacts suitable for PLCs yes (17 V, 5 ma) Short-circuit protection Fuse links Utilization category gl/gg A 6 fast A 10 Miniature circuit-breaker C-characteristics (to l k <= 0.5 ka; <= 260 V) A 6 1 ) Rated insulation voltage U i (pollution degree 3) V 690 Rated impulse withstand volltage U imp kv 6 Conductor cross-sections of auxiliary circuit Type of connection Screw connection Terminal screw Pozidriv size 2 Min./ max. conductor cross-sections finely stranded with end sleeve mm 2 2 x (0.5 to 1.5)/ 2 x (0.75 to 2.5) solid or stranded mm 2 2 x (0.5 to 1.5)/ 2 x (0.75 to 2.5) AWG conductor connections, AWG 2 x (18 to 14) solid or stranded Adapter for installing as a single unit For screw and snap-on mounting onto 35 mm standard mounting rail, size S3 also for 75 mm standard mounting rail Type 3RU19 16-3AA01 Conductor cross-sections main circuit 3RU19 26-3AA01 3RU19 36-3AA01 3RU19 46-3AA01 Type of connection Screw connection Box terminal Terminal screw Pozidriv Pozidriv Pozidriv 4 mm Allen screw Min./max. conductor cross-sections finely stranded with end sleeve mm 2 1 x (0.5 to 2.5) 1 x (1 to 6) 1 x (0.75 to 25) 1 x (2.5 to 50) Min./max. conductor cross-sections solid or stranded mm 2 1 x (0.5 to 4 2 ) 1 x (1 to 6) 1 x (0.75 to 35) 1 x (2.5 to 70) Min./max. conductor cross-sections AWG conductor connections, solid or stranded mm 2 1 x (18 to 14) 1 x (14 to 10) 1 x (18 to 2) 1 x (10 to 1/0) s-, u-, U-ratings Auxiliary circuit Switching capacity B600. R300 1) Up to I K 0,5 ka; 260 V. 2) Not acc. to IEC. 4/18 Siemens NS K 2000

SIRIUS 3R 3RB10 Solid-State Overload Relays CLASS 10 and CLASS 20 Technical data Short-circuit protection with fuses for motor feeders for short-circuit currents up to 50 ka at 690 V Overload relays contactor CLASS Fuse links 2 ) Current setting 5 and 10 20 NH Type 3NA NH British range Rated operational current I e DIAZED Type 5SB Type 3ND Standard U L -listed AC-3 in A bei NEOZED Type 5SE fuses fuses Type Type 400 V 500 V 690 V 400 V 500 V 690 V Utilization category gl/gg type of coordination 3 ) am BS88, Type T 1 2 2 1 2 Size S00 0.1 A to 0.4 A 3RT10 15 0.4 0.4 0.4 0.4 0.4 0.4 25 2 25 2 1.6 3RB10 16 0.4 A to 1.6 A 3RT10 15 1.6 1.6 1.6 1.6 1.6 1.6 25 6 35 6 6 3RB10 16 1.5 A to 6 A 3RT10 15 6 5 4 6 5 4 35 20 35 20 25 3RB10 16 3RT10 17 6 6 6 6 6 6 35 20 35 20 3 A to 12 A 3RT10 17 12 9 6.3 10 6 3 35 20 35 20 45 3RB10 16 Size S0 0.1 A to 0.4 A 3RT10 24 0.4 0.4 0.4 63 2 63 2 1.6 0.4 A to 1.6 A 3RT10 24 1.6 1.6 1.6 63 6 63 6 6 1.5 A to 6 A 3RT10 24 6 6 6 63 25 20 63 25 25 3 A to 12 A 3RT10 24 12 12 12 12 12 12 63 25 20 63 25 45 3RB10 26 6 A to 25 A 3RT10 24 12 12 12 12 12 12 63 25 20 63 25 70 3RB10 26 3RT10 25 17 17 13 16 16 13 63 25 20 63 25 70 3RT10 26 25 18 13 16 16 13 100 35 20 63 35 100 Size S2 6 A to 25 A 3RT10 34 25 25 25 22 22 22 125 63 50 125 63 100 3RB10 36 3RT10 35 25 25 25 25 25 25 125 63 50 125 63 100 13 A to 50 A 3RT10 34 32 32 31 22 22 22 125 63 50 125 63 125 3RB10 36 3RT10 35 40 40 40 29 29 29 125 63 50 125 63 150 3RT10 36 50 50 40 33 33 33 160 80 50 125 80 200 Size S3 13 A to 50 A 3RT10 44 50 50 50 49 49 49 250 100 63 250 100 200 3RB10 46 3RT10 45 50 50 50 50 50 50 250 100 80 250 100 200 25 A to 100 A 3RT10 44 65 65 57 49 49 49 250 125 63 250 125 250 3RB10 46 3RT10 45 80 80 80 53 53 53 250 160 80 250 160 350 3RT10 46 95 95 95 59 59 59 250 160 100 250 160 350 3TF50 1 ) 100 100 100 76 76 76 250 200 125 250 160 160 3TF51 1 ) 97 97 97 250 200 160 250 200 200 3TF52 1 ) 100 100 100 250 200 200 250 200 250 CLASS R K5 1) Mounting of contactor not possible, only installation as a single unit with individual wiring. 2) Observe the operational voltage. 3) Coordination and short-circuit equipment according to IEC 60 947-4-1/DIN VDE 660 Part 102. Type of coordination 1 : The contactor or starter must not endanger persons or the installation in the event of a short-circuit. They do not need to be suitable for further operation without repair and the renewal of parts. Type of coordination 2 : The contactor or starter must not endanger persons or the installation in the event of a short-circuit and must be suitable for further use. There is a danger of contact welding. Siemens NS K 2000 4/19

3RB10 Solid-State Overload Relays up to 100 A CLASS 10 and CLASS 20 SIRIUS 3R Description Specifications IEC 60 947-4-1, IEC 60 947-5-1 and DIN VDE 0660. 3RB10 overload relays are suitable for use in any climate. The devices are shock-hazardprotected acc. to DIN VDE 0106, Part 100. General The 3RB10 overload relays form part of the new SIRIUS 3R switchgear generation. The solid-state version of the SIRIUS 3R overload relay is noted for its extensive setting ranges (setting ratio 1:4), for the phase failure protection function (see characteristic curves) and also for the minimal energy requirement. In terms of dimensions and termination, the solid-state (3RB10) and the thermally delayed types (3RU11) are 100 % compatible. These devices are particularly suitable where motor protection requirements are high and for motor starting times up to 20 s (CLASS 20 version). A special coating of the printedcircuit board and of the electronic components assures reliable operation even in aggressive and tropical atmospheres. Four sizes and two variants are available up to 100 A. The overload relays are optimally matched, both electrically and mechanically, to the 3RT10 contactors or 3RW3 soft starter. They can, however, also be mounted separately with an adapter for installation as a single unit. Devices up to and including size S0 can be fitted on standard mounting rails without using tools. Application 3RB10 solid-state overload relays provide overload protection for three-phase induction motors with rated currents of up to 100 A (45 kw, AC-3, 400 V). For short-circuit protection with fuses or circuit-breakers, the fusing values of the contactors must be taken into account. Operation The solid-state overload relays have been developed for use in sinusoidal 50/60 Hz voltage networks. No additional power supply is required for operation. Current transformers (for measurement) are already integrated. An ASIC (applicationspecific integrated circuit) checks the current values of each phase and initiates release in the event of overload or phase failure. The tripping current corresponds to 114 % of the set current. The overload relays must be set to the rated motor current. Operation on frequency converters The 3RB10 solid-state overload relays are not suitable for the operation on frequency converters. (Use thermal overload relays.) Operation of single-phase motors The 3RB10 solid-state overload relay is not suitable for the operation of single-phase motors. Use the normal 3RU11 thermal overload relay instead. Trip classes The devices are available in CLASS 10 for normal starting (motor starting times up to 10 s) and in CLASS 20 for arduous startup conditions (motor starting times up to 20 s). Phase failure protection The 3RB10 solid-state overload relays are equipped with phasefailure protection. If a phase fails, the device trips after only 3s. STOP function Activating this function only affects the NC contact. Manual/automatic reset Manual or automatic reset can be selected with the blue button. The appropriate setting is selected by pressing and turning the button. Bei Automatik-RESET setzt das Überlastrelais nach einer Wiederbereitschaftszeit von 4 min zurück. Rücksetzen per Hand ist jederzeit möglich. Overload relays 3RB10 a s d f Test function and switch position indicator The switch position indicator also incorporates a test function which, when activated, simulates a tripped overload relay. Both auxiliary contacts are actuated and the switch position is indicated. Terminal for contactor coil and auxiliary contact When the 3RB10 16 overload relay (size S00) is mounted directly on the contactor, the auxiliary contact and coil terminal A2 of the contactor are fed through which considerably facilitates wiring. This is not necessary with sizes S0 as the contactors are equipped with 4 coil terminals. Auxiliary contacts The overload relays are equipped with an NC contact for disconnecting the contactor and an NO contact for signalling tripping. The breaking capacity of the switching contacts is very high so that the contactor coils can be switched directly. a Test function and switch position indicator s STOP button d Manual/automatic RESET selector switch f 1NO + 1NC g Trip class h Current setting screw, setting ratio 1:4 e. g. 3 to 12 A Mounting The overload relays are mounted directly on the 3RT10 contactors. If they are fitted individually on a connector base, they can be fastened by means of screws or placed on a mounting rail. The connector bases of the 3RU11 thermally delayed relays can be used. Accessories The accessories of the 3RU11 thermal overload relays can be used for the 3RB10 solid-state overload relays. Electrical remote RESET with different voltage variants. Mechanical remote RESET comprising a tappet, funnel and holder for actuating the switchgear cabinet door with 3SB1 pushbutton. Cable release for RESET for devices which are not easily accessible. Sealable cover. PTB Test Report The solid-state overload relay 3RB10 conforms to the specifications for overload protection of explosion-protected motors with the increased safety type of protection EEx e EN 50 019/ DIN VDE 0165, DIN VDE 0170/171 and PTB testing rules. PTB Test Report No. 3.43-8803/98 4/20 Siemens NS K 2000

SIRIUS 3R 3RB10 Solid-State Overload Relays CLASS 10 and CLASS 20 Description Time-current characteristics The time-current characteristics show the behavior at start with 3-pole loading : $ from cold state, % from warm state and & in the event of phase failure or current unbalance 40 % In the event of phase failure or current unbalance, the phase failure protection function becomes active. The overload relay trips after only 3 s. The characteristic curves of CLASS 10 and the behavior in operation are replicated from the 3RU overload relays. Trip classes of thermal, delayed magnetic or solid-state overload relays excerpt from IEC 60 947-4-1 CLASS Tripping time t A in seconds at 7,2 x I e from cold state CLASS 10 A 2 < t A 10 CLASS 10 4 < t A 10 CLASS 20 6 < t A 20 CLASS 30 9 < t A 30 Time-current characteristic for CLASS 10 Time-current characteristic for CLASS 20 Circuit diagrams 3RB10 16 overload relays 3RB10 26 to 3RB10 46 overload relays Siemens NS K 2000 4/21

3RB12 Solid-State Overload Relays CLASS 5 to CLASS 30 SIRIUS 3R Selection and ordering data 3RB12 Solid-State Overload Relays 3RB2 solid-state overload relays For trip classes 5/10/15/20/25/30, changeable Input T1/T2 for thermistor sensors (PTCs) for full motor protection Input C1/C2 for earth-fault detection with additional 3UL22 summation current transformer Manual/automatic/remote RESET Y1/Y2, test functions 2 outputs, 1 NO and 1 NC each 3 LEDs for operation and status displays Current setting range Rated control Mountable contactors Overload relays Weight supply voltage Order No. Price approx. A Type 1 unit kg 3RB12 solid-state overload relays 3RB12 46 1.25 1 ) to 6.3 110 V to 120 V 50/60 Hz Installation as a single 3RB12 46-1PG@@ 0,60 unit 220 V to 240 V 50/60 Hz 3RB12 46-1PM@@ 24 V DC 3RB12 46-1PB @@ 6.3 to 25 110 V to 120 V 50/60 Hz Install. as a single unit 3RB12 46-1QG@@ 0.60 220 V to 240 V 50/60 Hz 3RB12 46-1QM@@ 24 V DC 3RB12 46-1QB @@ 25 to 100 110 V to 120 V 50/60 Hz Install. as a single unit 3RB12 46-1EG@@ 0.60 220 V to 240 V 50/60 Hz 3RB12 46-1EM@@ 24 V DC 3RB12 46-1EB @@ 3RB12 53 50 to 205 110 V to 120 V 50/60 Hz 3TF50 to 3TF52 3RB12 53-0FG@@ 1.0 220 V to 240 V 50/60 Hz 3RB12 53-0FM@@ 24 V DC 3RB12 53-0FB @@ 3RB12 57 125 to 500 110 V to 120 V 50/60 Hz 3TF53 to 3TF57 3RB12 57-0KG@@ 1.90 220 V to 240 V 50/60 Hz 3RB12 57-0KM@@ 24 V DC 3RB12 57-0KB @@ 3RB12 62 200 to 820 110 V to 120 V 50/60 Hz 3TF68. 3TF69 3RB12 62-0LG@@ 3.20 220 V to 240 V 50/60 Hz 3RB12 62-0LM@@ 24 V DC 3RB12 62-0LB @@ Order No. supplement Standard version Design Order No. supplement Additional price 3RB12..-...@@ } Preferred type 1 NO + 1 NC 1 NO + 1 NC Overload/thermistor Earth-fault } RB12..-... 0 0 Overload/thermistor/ Overload warning } 3RB12..-... 1 0 earth-fault Version with internal earth-fault detection 2 ) Same as standard version, but additionally with internal earth-fault detection, for 3-conductor networks only, not for single-phase motors, but suitable for star-delta switching. 1 NO + 1 NC 1 NO + 1 NC Overload/thermistor Earth-fault 3RB12..-... 2 0 Overload/thermistor/ Overload warning 3RB12..-... 3 0 earth-fault Bistable version Same as standard version, but with the bistable output relay, no change in the switching state of the auxiliary contacts in the event of failure of the control supply voltage. 1 NO + 1 NC 1 NO + 1 NC Overload/thermistor Earth-fault 3RB12..-... 0 1 Overload/thermistor/ Overload warning 3RB12..-... 1 1 earth-fault 1) The setting range from 0.25 A to 1.25 A is obtained by multiple winding of the main conducting paths. 2) The internal earth-fault detection detects fault currents > 30% from the set current. 4/22 Siemens NS K 2000

SIRIUS 3R 3RB12 Solid-State Overload Relays CLASS 5 to CLASS 30 Selection and ordering data 3RB12 solid-state overload relays with analog output, same as standard version 3RB12..-... 00, but additionally with analog output signal 4 to 20 ma fot the motor current, referred to the set current value. For measuring instruments with 4 to 20 ma input or for processing in control systems, e.g. - moving coil indicator, front dimensions 96 mm x 96 mm, Order No. M01604-P9270 - changing scale 0 to 125 %, Order No. M01733-V0016-Z406. For other versions, see catalog MP12 B. Overload display up to 125 % of the set current (corresponds to 20 ma). Motor current = current setting corresponds to 16.8 ma = 100 %. Communication via ASi with analog module 3RK12 07-1BQ00-0AA3 possible. Current setting range Rated Mountable contactors Overload relays Weight control supply voltage Order No. Price approx. A Type } Preferred type 1 unit kg 3RB12 solid-state overload relays with analog output 3RB12 46 1.25 1 ) up to 6.3 110 V to 120 V 50/60 Hz Install. as a single unit } 3RB12 46-1PG40 0.60 220 V to 240 V 50/60 Hz } 3RB12 46-1PM40 24 V DC } 3RB12 46-1PB40 6.3 up to 25 110 V to 120 V 50/60 Hz Install. as a single unit } 3RB12 46-1QG40 0.60 220 V to 240 V 50/60 Hz } 3RB12 46-1QM40 24 V DC } 3RB12 46-1QB40 25 up to 100 110 V to 120 V 50/60 Hz Install. as a single unit } 3RB12 46-1EG40 0.60 220 V to 240 V 50/60 Hz } 3RB12 46-1EM40 24 V DC } 3RB12 46-1EB40 3RB12 53 50 up to 205 110 V to 120 V 50/60 Hz 3TF50 to 3TF52 } 3RB12 53-0FG40 1.0 220 V to 240 V 50/60 Hz } 3RB12 53-0FM40 24 V DC } 3RB12 53-0FB40 3RB12 57 125 up to 500 110 V to 120 V 50/60 Hz 3TF53 to 3TF57 } 3RB12 57-0KG40 1.90 220 V to 240 V 50/60 Hz } 3RB12 57-0KM40 24 V DC } 3RB12 57-0KB40 3RB12 62 200 up to 820 110 V to 120 V 50/60 Hz 3TF68. 3TF69 } 3RB12 62-0LG40 3.20 220 V to 240 V 50/60 Hz } 3RB12 62-0LM40 24 V DC } 3RB12 62-0LB40 Accessories for 3RB12 overload relays Window size Rated fault current I n Order No. Price Weight mm A 1 unit kg Summation current transformer for external earth-fault detection 40 0.3 3UL22 01-1A 0.35 0.5 3UL22 01-2A 1 3UL22 01-3A 65 0.3 3UL22 02-1A 0.60 0.5 3UL22 02-2A 1 3UL22 02-3A 120 0.3 3UL22 03-1A 2.50 0.5 3UL22 03-2A 1 3UL22 03-3A Direct voltage adapter For operation of a 3RB12 with the control supply voltage of 24 V DC at DC voltages from 30 V to 120 V 7PX80 40-0A 0.30 1) The setting range from 0.25 A to 1.25 A is obtained by multiple winding of the main conducting paths. Siemens NS K 2000 4/23

3RB12 Solid-State Overload Relays CLASS 5 to CLASS 30 SIRIUS 3R Accessories Design For type Order No. Price Weight approx. Pack. 1 unit kg Unit Sealable cap 3RB19 00-0A for current-setting knob and CLASS selector 3RB12 3RB19 00-0A 0.01 1 Push-in lugs 3RB19 00-0B for screw mounting onto a mounting plate 2 items required per overload relays (1 set = 10 items). 3RB12 46 3RB19 00-0B 0.01 10 Terminal cover 3TX7 506-0A Terminal cover for installation as a single unit or load-side when directly mounted 3RB12 53 3TX7 506-0A 0.01 10 3RB12 57 3TX7 536-0A 0.003 2 3RB12 62 3TX7 686-0A 0.17 2 with 3TF68 3RB12 62 with 3TF69 3TX7 696-0A 0.17 2 3TX7 506-0B Terminal cover between contactor and overload relay when directly mounted 3RB12 53 3TX7 506-0B 0.01 10 3RB12 57 3TX7 536-0B 0.065 10 3RB12 62 3TX7 686-0B 0.065 10 with 3TF68 3RB12 62 with 3TF69 3TX7 696-0B 0.065 10 Base plate 3UF19 00-0JA00 for snap-on mounting on 75 mm standard mounting rail 3RB12 53 3UF19 00-0JA00 0.2 1 4/24 Siemens NS K 2000

SIRIUS 3R 3RB12 Solid-State Overload Relays CLASS 5 to CLASS 30 Technical data Tripping In case of overload, phase failure and current unbalance ( >40% of the current setting I e ) as well as with responding of the thermistor motor protection and in case of earth fault Trip class Selectable; CLASS 5, 10, 15, 20, 25, 30 PTB Test Report (increased safety EExe Nr.:) 3.53-3907/96 Overload warning Above 1.15 x I e with balanced loading; above 0.85 x I e with unbalanced loading Operation Combined TEST/RESET button with functional test; automatic and remote RESET possible; rotary knob of current setting I e ; 6-step rotary switch for trip class (CLASS 5 to 30) Display green LED Ready Steady light ON; ready for operation OFF; no control supply voltage or functional test was negative (device is locked) red LED Overload Steady light Overload tripping by current and/or thermistor Flashing light Overload warning red LED Ground Fault Steady light Earth-fault Permissible ambient/storage temperature 25 C to +70 C/ 40 C to +80 C Mounting altitude to 2000 m above sea level Degree of protection (acc. to IEC 529) IP 20 ( 100 A max. setting current I e ); IP 00 (>100 A max. current setting I e ) Shock resistance (sine pulse) 15 g/11 ms Type of construction Compact, i. e. the current transformers for all sizes are already integrated in the housing Dimensions W x H x D Mounting position Fitting EMC immunity mm x mm x mm 3RB12 46 (I e 100 A): 70 x 85 x 132.5; 3RB12 53 (I e 205 A): 120 x 145 x 155; 3RB12 57 (I e 500 A): 145 x 160 x 175; 3RB12 62 (I e 820 A): 230 x175 x190 any 3RB12 46; snap-on mounting on 35-mm-standard mounting rail or screw mounting with accessories 3RB12 53; 3RB12 57; 3RB12 62: can be directly mounted on the contactor or screw mounting Conducted interference injection, burst acc. to IEC 61 000-4-4: 2 kv (corresponds to severity 3) Conducted interference injection, surge acc. to IEC 61 000-4-5: 2 kv (corresponds to severity 3) Electrostatic discharge acc. to IEC 61 000-4-2: 8 kv (corresponds to severity 3) Field-generated interference injection acc. to IEC 61 000-4-3: 10 V/m (corresponds to severity 3) EMC emitted interference Limit-value class B acc. to EN 55 011 Main circuit Rated insulation voltage U i (pollution degree 3) Rated operational voltage U e Rated impulse withstand voltage U imp Rated frequency and type of current Short-circuit protection Diameter of the cut-outs ( 100 A max. I e ) with fuses with circuit-breaker 3RB12 46: 690 V for blank/unisolated conductors; 1000 V for isolated conductors 3RB12 53, 3RB12 57, 3RB12 62: 1000 V 3RB12 46: 690 V; 3RB12 53, 3RB12 57, 3RB12 62: 1000 V general 3RB12 46: 6 kv 3RB12 53, 3RB12 57, 3RB12 62: 8 kv 50/60 Hz; 3-phase and for protection of single-phase motors (see circuit diagrams) 1 ) 2 ) 10 mm (devices with max. current setting I e 25 A); 15 mm (devices with max. current setting I e 100 A ); (devices with max. current setting I e >100 A: mounting with connecting bars) Busbar connection (>100 A max. I e ) 3RB12 53 3RB12 57 3RB12 62 tightening torque Nm M 8: 10 to 14 M 10: 14 to 24 M 10: 14 to 24; M 12: 20 to 35 finely stranded with cable lug mm 2 35 to 95 50 to 240 50 to 240 stranded with cable lug mm 2 50 to 120 70 to 240 185 to 240 1) See table on page 4/27. 2) See Part 5. Siemens NS K 2000 4/25

3RB12 Solid-State Overload Relays CLASS 5 to CLASS 30 SIRIUS 3R Technical data Auxiliary circuit/control circuit Auxiliary contacts (electrically isolated) Recovery time 1 NO/1 NC for overload tripping due to current and/or thermistor; 1 NO/1 NC for earth-fault tripping or 1 NO/1 NC for overload tripping due to current and/or thermistor and/or earth-fault : 1 NO/1 NC for overload warning 5 (fixed), after tripping due to overcurrent. After tripping by the thermistor as long as the motor temperature has not fallen to 5 K below the operating temperature of the thermistor. Rated insulation voltage U i 300 V (pollution degree 3) Rated impulse withstand voltage U imp 4 kv Conventional thermal current 6 A Rated operational current Switching capacity: AC-15: 6 A/24 V; 6 A/120 V; 3 A/230 V; DC-13: 2 A/24 V; 0.55 A/60 V; 0.25 A/125 V Rated control supply voltage U s AC 50/60 Hz: 110 V to 120 V; 220 V to 240 V; DC: 24 V Operating range AC 50/60 Hz: 0.85 to 1.1 x U s, 2 VA; DC 24 V: 0.85 to 1.2 x U s (DIN 19 240), 2 W Power failure stored-energy time 200 ms Thermistor protection (PTC thermistor sensor) Summated cold resistance: 1.5 kω; Response value: 2.7 kω to 3.1 kω; fall-back value: 1.5 kω to 1.65 kω Response time after earth-fault detection External: 200 ms to 500 ms; internal: 500 ms to 1000 ms Short-circuit protection Fuse links utilization category gl/gg 6 A, fast 10 A; miniature circuit-breaker 1.6 A; C-characteristics Conductor cross-sections tightening torque 0.8 Nm to 1.2 Nm solid 1 x (0.5 mm 2 to 4.0 mm 2 ); 2 x (0.5 mm 2 to 2.5 mm 2 ) finely stranded with/without end sleeve 1 x (0.5 mm 2 to 2.5 mm 2 ); 2 x (0.5 mm 2 to 1.5 mm 2 ) Analog output Output signal 4 to 20 ma Measurement range 0 to 1.25 I e 4 ma 0 I e 16.8 ma 1.0 I e 20 ma 1.25 I e Resolution 10 bit (approx. 1/8 %) 4/26 Siemens NS K 2000

SIRIUS 3R 3RB12 Solid-State Overload Relays CLASS 5 to CLASS 30 Technical data Short-circuit protection with fuses for motor feeders for short-circuit currents up to 50 ka at 690 V for 3RB12 and 3UF50 Overload relays Contactor CLASS Fuse links 3) Current setting 5 and 10 15 20 25 30 NH Type 3NA NH British U L -listed range Rated operational current I e DIAZED Type 5SB Type 3ND Standards fuses AC-3 in A at NEOZED Type 5SE fuses Utilization category gl (gg) am BS88 RK5 Type of coordination 4 ) Type T (Type) 400 V 500 V 690 V 400 V 500 V 690 V 400 V 500 V 690 V 400 V 500 V 690 V 400 V 500 V 690 V 1 2 2 2 1.25 to 6.3 A 3RB1246-1P 3RT1015 6.3 5.0 4.0 6.3 5.0 4.0 6.3 5.0 4.0 6.3 5.0 4.0 6.3 5.0 4.0 35 20 20 25 3UF50 0 3RT1016 6.3 6.3 5.2 6.3 6.3 5.2 6.3 6.3 5.2 6.3 6.3 5.2 6.3 6.3 5.2 35 20 20 25 3RT1017 6.3 6.3 6.3 6.3 6.3 6.3 6.3 6.3 6.3 6.3 6.3 6.3 6.3 6.3 6.3 35 20 20 25 6.3 to 25 A 3RB1246-1Q 3RT1015 7.0 5.0 4.0 7.0 5.0 4.0 7.0 5.0 4.0 7.0 5.0 4.0 7.0 5.0 4.0 35 20 20 60 3UF50 1 3RT1016 9.0 6.5 5.2 9.0 6.5 5.2 9.0 6.5 5.2 9.0 6.5 5.2 9.0 6.5 5.2 35 20 20 60 3RT1017 12.0 9.0 6.3 11.0 9.0 6.3 10.0 9.0 6.3 9.5 9.0 6.3 9.0 9.0 6.3 35 20 20 60 3RT1024 12.0 12.0 9.0 12.0 12.0 9.0 12.0 12.0 9.0 12.0 12.0 9.0 12.0 12.0 9.0 63 25 20 25 70 3RT1025 17.0 17.0 13.0 17.0 17.0 13.0 16.0 16.0 13.0 15.0 15.0 13.0 14.0 14.0 13.0 63 25 20 25 70 3RT1026 25.0 18.0 13.0 18.0 18.0 13.0 16.0 16.0 13.0 15.0 15.0 13.0 14.0 14.0 13.0 100 35 20 35 100 3RT1034 25.0 25.0 25.0 25.0 25.0 25.0 22.3 22.3 22.3 20.3 20.3 20.3 19.1 19.1 19.1 125 63 50 63 100 3RT1035 25.0 25.0 25.0 25.0 25.0 25.0 25.0 25.0 25.0 125 63 50 63 100 25 to 100 A 3RB1246-1E 3RT1034 32.0 32.0 20 25.5 25.5 20 125 63 50 63 125 3UF50 3 3RT1035 40.0 40.0 24 33.0 33.0 24 29.4 29.4 24 28.0 28.0 24 26.5 26.5 24 125 63 50 63 150 3RT1036 50.0 50.0 24 38.5 38.5 24 32.7 32.7 24 29.4 29.4 24 26.5 26.5 24 160 80 50 80 200 3RT1044 65.0 65.0 47 56.0 56.0 47 49.0 49.0 47 45.0 45.0 45.0 41.7 41.7 41.7 250 125 63 125 250 3RT1045 80 80 58 61 61 58 53 53 53 47 47 47 45 45 45 250 160 80 160 250 3RT1046 95 95 58 69 69 58 59 59 58 53 52 53 50 50 50 250 160 100 160 350 3TF50 100 100 100 87 87 87 76 76 76 71 71 71 65 65 65 400 224 125 160 175 3TF51 100 100 100 97 97 97 90 90 90 83 83 83 400 250 160 200 200 3TF52 100 100 100 100 100 100 100 100 100 400 250 200 200 200 50 to 205 A 3RB1253-0F 3TF50 1 ) 110 110 110 87 87 87 76 76 76 76 76 71 64 64 64 400 224 125 160 175 3UF50 3 3TF51 2 ) 140 140 110 111 111 110 97 97 97 97 97 90 83 83 83 400 250 160 200 200 3TF52 2 ) 170 170 170 135 135 135 118 118 118 118 118 109 101 101 101 400 250 200 250 200 3TF53 205 205 205 162 162 162 143 143 143 143 143 132 122 122 122 400 250 250 250 300 3TF54 198 198 198 174 174 174 174 174 161 149 149 149 400 250 250 250 300 3TF55 205 205 205 205 205 205 205 205 194 178 178 178 400 250 250 250 300 3TF56 205 205 205 205 400 250 250 250 400 125 to 500 A 3RB1257-0K 3TF52 170 170 170 135 135 135 400 250 200 250 200 3UF50 4 3TF53 2 ) 205 205 170 162 162 162 143 143 143 143 143 132 400 250 250 315 300 3TF54 2 ) 250 250 250 198 198 198 174 174 174 174 174 161 149 149 149 500 400 250 355 300 3TF55 2 ) 300 300 250 238 238 238 208 208 208 208 208 194 178 178 178 500 400 315 400 300 3TF56 2 ) 400 400 400 318 318 318 278 278 278 278 278 259 238 238 238 800 500 400 450 400 3TF57 2 ) 475 475 400 378 378 378 332 332 332 332 332 307 284 284 284 800 500 630 500 400 3TF68 500 500 500 500 500 500 440 440 440 440 440 408 376 376 376 800 500 630 500 1200 3TF69 500 500 500 500 500 500 500 500 500 800 500 630 500 CLASS L 200 to 820 A 3RB1262-0L 3TF68 2 ) 630 630 630 502 502 502 440 440 440 440 440 408 376 376 376 1000 500 630 500 1200 3UF50 5 3TF69 2 ) 820 820 820 662 662 662 572 572 572 572 572 531 500 500 500 1250 630 630 630 CLASS L 1) Mounting of contactor is possible (after removing the box terminal block 2) Mounting of contactor is possible. 3) Observe the operational voltage. 4) Coordination and short-circuit equipment according to IEC 60947-4-1/DIN VDE 660 Part 102 Type of coordination 1 : The contactor or starter must not endanger persons or the installation in the event of a short-circuit. They do not need to be suitable for further operation without repair and the renewal of parts. Type of coodination 2 : The contactor or starter must not endanger persons or the installation in the event of a short-circuit and must be suitable for further use. There is a danger of contact welding. Siemens NS K 2000 4/27

3RB12 Solid-State Overload Relays CLASS 5 to CLASS 30 SIRIUS 3R Description Functions Tripping in the event of overload, current unbalance, phase failure or blocked rotor. Full motor protection by connection of a thermistor (PTC sensor circuit in the motor coil) possible; it is deactivated by the prefitted wire jumper A (see front view). The monitoring system of the termistor is fail-safe, i. e. a wire break causes tripping. Earth-fault monitoring - internal for motors with 3- lead connection (earth-fault detection in the event of fault currents > 30 % of the current setting I e ) - The units with internal earthfault detection are not suitable for operation in star/ delta combinations. - external for motors with 3 and 4-lead connection by connection of a 3UL22 0.. A summation current transformer (reliable earth-fault detection in the event of fault currents of 0.3 A, 0.5 A and 1 A). These values are applicable for sinusoidal currents of 50/60 Hz Overload warning above - 1.15 I e with balanced load - 0.85 I e with unbalanced load - display by flashing overload LED at the unit or external via 1 NO/1 NC (according to the version of the unit) Electrically isolated auxiliary contact Function according to version: - 1 NO/1 NC for overload tripping by current and/or thermistor 1 NO/1 NC for earth-fault tripping - 1 NO/1 NC for overload tripping by current and/or thermistor and earth fault 1 NO/1 NC for overload warning Versions of the unit with monostable or bistable functioning of the output relays 3 LED displays ( Ready, Ground Fault, Overload ) Combined TEST-/RESETbutton with function test Remote and automatic RESET by means of external wiring is possible (an automatic RESET in the event of tripping by earth-fault has no effect) Selectable trip class (time-lag class): CLASS 5/10/15/20/25/ 30 Large ranges of the set current I e High tripping precision Current detection immune to harmonics Temperature range from 25 C to +70 C Self-monitoring, i.e. the units trips in the event of an internal fault Versions of the unit for control supply voltages of 24 V DC, 110 to 120 V AC, 220 to 240 V AC. Operation on frequency converters The 3RB12 solid-state relays are suitable for operation on frequency converters. 3RB12 overload relays with analog output With the aid of the microprocessor, the measured motor current is converted to an analog DC 4 ma to 20 ma output signal. The maximum current of the 3 phases is always output. An output signal of 20 ma corresponds to 1.25 times the set value. The current setting of the 3RB12 defines calculation of the absolute current value. With the output signal, moving coil instruments with a 4 ma to 20 ma input can be controlled (final scale value for all sizes 125 %) or analog inputs of programmable logic controllers can be fed. With an analog AS-Interface module (current), the current values can be transferred via AS-Interface. 3RB12 overload relays (front view) 1 Terminals for control supply voltage 2 Green LED Ready 3 Red LED Ground Fault 4 Red LED Overload 5 TEST-/RESET button 6 1 NO/1 NC for overload/ thermistor tripping or 1 NO/1 NC for overload/ thermistor/earth-fault tripping 7 Thermistor terminals 8 Terminals for external summation current transformer 9 Terminals for remote or automatic RESET 10 Rotary button for current setting 11 CLASS selector rotary knob 12 1 NO/1 NC for earth-fault tripping or 1 NO/1 NC for overload warning 13 Analog output 4... 20 ma PTB Test Report The 3RB12 solid-state overload relay complies with the specifications for the overload protection of flameproof motors of protection type increased safety EEx e EN 50 019/ DIN VDE 0165, DIN VDE 0170/ 171 and PTB test regulations. For overload relays with DC operation, the electrical isolation must be assured by means of a battery supply or a safety transformer according to DIN VDE 0551. With 3RB12..-....1 units (no change of the switching state of the auxiliary contacts in the case of failure of the control suply voltage) for protection of EEx e electrical motors, separate monitoring of the control supply voltage is recommended. PTB Test Report No. 3.53-3907/96 Tripping characteristics The time-current characteristic for 3-pole symmetric loading shows the dependence of the tripping time from a cold state on multiples of the current setting. If the unit is pre-loaded with 100 % of the current setting, the tripping times are shortened to approx. 30 %. In the event of 2-pole loading (failure of a phase) or a current unbalance > 40 % of the current setting, the 2-pole characteristic applies. Time-current characteristic for 3-pole loading Time-current characteristic for 2-pole loading 4/28 Siemens NS K 2000

SIRIUS 3R 3RB12 Solid-State Overload Relays CLASS 5 to CLASS 30 Mode of operation and control The currently flowing motor current is detected in each phase via current transformers and continuously monitored by a microprocessor. If an overload > 110 % of the current I e occurs which is set with the rotary knob on the front of the unit, if there is a current unbalance > 40 % of I e or if a phase-failure occurs, tripping is initiated by the switching of two auxiliary contacts (1 NO/1 NC) after expiry of the tripping time which is set with the six-step rotary switch (CLASS 5/10/15/20/25/30 see tripping characteristics). Resetting, either by pressing the TEST/RESET button on the unit or by remote or automatic RESET, is possible after the recovery time of 5 min has elapsed. Tripping due to responding of the thermistor sensor occurs via the same auxiliary contacts but without a time delay. Here, resetting is not possible until the temperature in the motor coil has fallen to 5 K below the operating temperature of the thermistor. In the event of an earth-fault, the unit trips without a time delay. According to the version of the unit, this may happen via a separate output (1 NO/1 NC). Resetting of the unit is possible in this case without a time delay/ without elapsing of a recovery time. A test of the unit s functions, namely current detection, the thermistor and earth-fault input, and of the tripping functions of the auxiliary contacts can be initiated by pressing the TEST/RE- SET button. The test of the unit s functions can also be carried out during operation (LED signals). A self-monitoring feature also causes the unit to trip when an internal fault occurs. In this case resetting is not possible. Specifications IEC 60 947-4-1/ DIN VDE 0660 Part 102; IEC 60 947-5-1/ DIN VDE 0680 Part 200; IEC 60 801-2, -3, -4, -5; UL 508/CSA C 22.2. Function in the event of control supply voltage failure Application Overload relays are used for protecting electrical equipment against overheating (3-phase motors, transformers,...). This can be caused by overloading, unbalanced current input, phase failure (main leads) or a blocked rotor. Solid-state overload relays provide highly-sophisticated motor-protection such as high precision of the tripping characteristic with a tolerance of < ±10 % fine adaptation to normal or heavy starting duty by means of an adjustable trip class (CLASS 5/10/15/20/25/30) independence from outside influence such as shocks, different cable cross-sections, temperature fluctuations, aggressive surroundings or ageing a defined recovery time (here 5min). Description In the case of a long-time failure of the control supply voltage (> 0.2 s), the output relays react in different ways depending on the version: monostable or bistable. Function of the output relays Monostable Bistable at: 3RB12..-.... 0 3RB12..-.... 1 Failure of the control supply voltage Unit trips No change in the switching state of the auxiliary contacts Return of the control supply voltage without trip Return of the control supply voltage after trip Unit resets Mono- and bistable 3RB12 solid-state overload relays No change in the switching state of the auxiliary contacts Unit remains tripped Unit remains tripped Resetting: Resetting: In the event of overload tripping, In the event of overload tripping, after after 5 min; 5min; in the event of thermistor tripping in the event of thermistor tripping when when 5 K below the operating 5 K below the operating temperature; temperature; in the event of earth-fault in the event of earth-fault tripping, tripping, immediately immediately The 3RB12 electronic overload relays enable protection of electrical equipment and installations with three different protective mechanisms in one unit: overload protection with permanent monitoring of the individual currents in the motor leads thermistor motor protection with evaluation of a PTC thermistor sensor circuit earth-fault protection: internal In the event of a motor current between 0.3 times and twice the current setting, the unit trips at an earth-fault current that amounts to 30 % of the current setting. In the event of a motor current between twice and eight times the current setting, the unit trips at an earth-fault current that amounts to 15 % of the motor current. The response delay is 0.5 to 1s. external for motors with 3 and 4-lead connection by connection of a 3UL22 0.. A summation current transformer (reliable earth-fault detection in the event of fault currents of 0.3 A, 0.5 A and 1 A). Thermistor protection (full motor protection) is provided by a PTC temperature sensor (e. g. for motors whose stator is the critical component, motors with long starting and breaking procedures, motors with impeded cooling or with high ambient temperatures). Additional evaluation equipment is not needed. Less space and wiring are therefore required. Siemens NS K 2000 4/29

3RB12 Solid-State Overload Relays CLASS 5 to CLASS 30 SIRIUS 3R Description Design and mounting The current transformers for all sizes of the 3RB12 electronic overload relays are already integrated in the housing. Units with current setting ranges < 100 A (overall width 70 mm) are designed for single installation due to the push-through system used. With this system, the main power leads for rated motor currents of 1.25 A to 100 A are simply pushed through the current transformer integrated in the compact unit ( first loop ). Additional installation work and power losses at the transfer resistor of the terminal points which are otherwise needed are thus avoided. For rated motor currents I N smaller than 1.25 A, the motor leads in each phase can be taken through the loop-through holes several times (n times). The current setting I e of the unit can then be calculated to I e =n I N (e.g.: I N = 0.5 A; n = 3; I e = 3 0.5 A = 1.5 A). n = 5 is recommended as the practical upper limit. Units with 70 mm overall width are either snapped onto a 35 mm standard mounting rail in accordance with EN 50 022 or are screwed onto a mounting plate by means of push-in lugs which are available as accessories. For current setting ranges > 50 A to 820 A (overall width: 120 mm, 145 mm and 230 mm) the 3RB12 electronic overload relays can be directly mounted on the contactors via connecting rails. The screw mounting for these units is integrated in the housing. For 3RB12 53 units (overall width: 120 mm), a baseplate is also available for snap-on mounting on a 75-mm mounting rail. Internal circuit diagrams Connection diagrams 3RB12 overload relays standard version Protection of single-phase motors 3RB12 46-... 0., -... 1.; (Only in the case of units without internal earth-fault detection) 3RB12 53-... 0., -... 1. 3RB12 57-... 0., -... 1. 3RB12 62-... 0., -... 1. ϑ ϑ 4/30 Siemens NS K 2000

3UA6 Thermally Delayed Overload Relays Overload relays for mounting onto contactor and installation as a single unit for snap-on and screw mounting snapping onto 35 mm stand. mounting rail acc. to EN 50 022 3UA6 Thermally Delayed Overload Relays Thermally delayed overload relays 3UA60, 3UA61 and 3UA62 STOP button Test function Integrated sealable cover SIRIUS 3RU19 accessories can be used Trip class CLASS 10 Auxiliary contacts 1 NO + 1 NC Manual/automatic RESET Switch position indicator Phase failure sensitivity up to 205 A CLASS 10 Selection and ordering data For contactor Overload relays Weight Current setting range Order No. approx. A } Preferred type kg 3TF50 55 to 80 } 3UA60 01-2H 0.7 63 to 90 } 3UA60 01-2W 80 to 110 } 3UA60 01-2X 90 to 120 } 3UA60 01-3H 110 to 135 } 3UA60 01-3J 3TF51 55 to 80 } 3UA61 01-2H 0.7 63 to 90 } 3UA61 01-2W 80 to 110 } 3UA61 01-2X 90 to 120 } 3UA61 01-3H 110 to 135 } 3UA61 01-3J 120 to150 } 3UA61 01-3K 3TF52 55 to 80 } 3UA62 01-2H 0.7 63 to 90 } 3UA62 01-2W 80 to 110 } 3UA62 01-2X 90 to 120 } 3UA62 01-3H 110 to 135 } 3UA62 01-3J 120 to 150 } 3UA62 01-3K 135 to 160 1 ) } 3UA62 01-3L 3TF53 170 to 205 1 ) } 3UA62 01-3N 0.7 1) From setting range 135 to 180 A, installation as a single unit is required (heat dissipation). Siemens NS K 2000 4/31

3UA6 and 3RB12 Overload Relays up to 820 A CLASS 10 and 5 up to 30 s Selection and ordering data 3UA6 and 3RB12 Overload Relays Overload relays for installing as a single unit 3UA66 and 3UA68 overload relays with snap-on mounting onto 75 mm standard mounting rail acc. to EN 50 023 3RB12 overload relays for screw mounting or for direct mounting to the 3TF5 and 3TF6 contactors 3UA66 and 3UA68 overload relays with Current transformer Auxiliary contacts Trip class CLASS 10 A Manual/automatic RESET Switch position indicator Phase failure sensitivity 3RB12 solid-state overload relays with Current transformer Auxiliary contacts 2 NO + 2 NC Trip classes CLASS 5 to 30, changeable Manual/automatic/remote RESET Phase failure sensitivity Test functions and 3 LEDs Rated control supply voltage 50/60 Hz, 230 V See 3RB12 for further information and versions. Overload relays Weight Overload relays Weight Current setting range Order No. approx. Current setting range Order No. Price approx. A n Obsolescent type with replacement kg A } Preferred type kg type 80 to 125 3UA66 00-2K 2.5 50 to 205 } 3RB12 53-0FM00 1 125 to 200 3UA66 00-3B 50 to 205 } 3RB12 53-0FM00 160 to 250 3UA66 00-3C 125 to 500 } 3RB12 57-0KM00 1.9 200 to 320 3UA66 00-3D 125 to 500 } 3RB12 57-0KM00 250 to 400 3UA66 00-3E 125 to 500 } 3RB12 57-0KM00 320 to 500 n 3UA68 00-3F 3 125 to 500 } 3RB12 57-0KM00 1.9 400 to 630 n 3UA68 00-3G 200 to 820 } 3RB12 62-0LM00 3.2 4/32 Siemens NS K 2000