lubrication systems CME Electric pump for oil and soft grease volumetric

Similar documents
Compact Units. For fluid grease, NLGI grades 000, 00 Group MKF 0.1 or 0.2 l/min EN

Motor-driven pump unit GSJB

PTEX extruder pumps Pneumatic extruder pump for drums of grease up to NLGI grade 2

For high-viscosity oils and fluid grease of NLGI grades 000, 00 For use in SKF MonoFlex single-line centralized lubrication systems

lubrication systems PEGPEO 5N-10N-25N-210N pumps for progressive systems

Inexpensive solution for the lubrication of linear guides and rolling bearings

Single-Line Centralized Lubrication Systems

SKF Grease injection system

Manually or pneumatically actuated Piston pumps

PPU, PHU Piston Pumps for progressive grease and oil systems, pneumatically or hydraulically actuated

Grease Pump Units. For progressive and multiline systems, manually, pneumatically or hydraulically actuated. Please note!

Piston Pumps with Reservoir

Injection oilers, micro pumps for minimal quantity metering

ELECTRIC GREASE AND OIL PUMPS ILC-MAX

Electric Plug-and-Socket Connectors

SKF Maxilube pumping centre. for SKF DuoFlex, dual-line lubrication systems

MPS AND MPS PR¼ 16 OUTPUT DEMAND CONTROLLER PENTAIR CLEAN AIR SYSTEMS. AVS Danmark ApS Skelvej Hedehusene

Grease Pump Units For progressive and multiline systems, manually, pneumatically or hydraulically actuated

Injection oilers, micro pumps

SKF Multilube pumping unit

Injection Oilers, Micro Pumps

For grease For application in SKF DuoFlex dual-line centralized lubrication systems

GVP, chain lubrication

SureFire II Lubricator

SKF VectoLub, VE1B units

Block feeder SPVS Used in oil or grease lubrication systems

Grease Lubrication Pump FK

Block feeder SPVS Used in oil or grease lubrication systems

" " (495) For oil For continuous monitored lubrication with minimum quantities from 0,5 to 5 mm³/min

Metering Units and Piston Distributors with Quick Connector System

UD and UC Gear pump unit

Chain lubrication, accessories Nozzles, oiling-brushes, reservoirs and other accessories for the chain lubrication EN

Flow Monitors and Sensors

Standard filter Disk filter Return filter. Lubrication systems can fail from the following

Chain lubrication, accessories

for SKF DuoFlex dual-line lubrication systems

Accessories for Minimal Quantity Metering

Standard filter Disk filter Return filter. Lubrication systems can fail from the following

Flow limiter SP/SMB3 Flow limiter SP/SMB6

SGA and SG-dosers. for SKF DuoFlex dual-line lubrication systems

Directional Valves for oil or grease

EC DECLARATION OF CONFORMITY

REV lubrication systems PEGPEO Electropumps for progressive systems

SureFire II Lubricator

DEVICE STATE/BYPASSED FAILURE OVERLOAD

Product series DSA, DSB, DSC, DSD

DPL MONOBLOCK PROGRESSIVE DIVIDERS

ILC PICO-MAX ELECTRIC GREASE PUMP Automatically Lubricates Small, Medium and Large Machinery

Piston Distributors, Metering Units

Lubrication System CLU4

Grease-lubricating pump FF... DSK US (05.05)

MultiPort Lubricator. Electric motor-driven, Grease and Oil. General. Technical Data. Motor R3 09/09

DKG-114 MANUAL AND REMOTE START UNIT

Lubrication System CLU4

SKF VectoLub, accessories Accessories for the minimal quantity lubrication systems VTEC and VE1B EN

SP/SMT 1 Flow Divider

Lubrication systems for agricultural machines

Electric pump EP-1. Electric pump with 1.9 kg reservoir:

LUBRICATION PUMP PMP CENTRAL LUBRICATION

LUBRICATION PUMP PMP CENTRAL LUBRICATION

On Demand, Differential Pressure Controls

16000SIII Automatic Grease System

Flow limiter SP/SMB13 for line installation in circulating-oil lubrication systems.

GREASE NLGI (*) OIL CST (*) PRESSURE (220.5) (147) - 20 (294) (220.5)

JM Oil Lubrication Pump SKF MultiFlex multi-line pump units for total loss oil lubrication systems on compressors

Compact Units for Oil

Single- and Multicircuit Pumps

Automatic concealed bollards 275 H600 and 275 H800 Control station

Magnetic switch For bypass level indicators Model BGU for nuclear power plants

LUBRICATION PUMP SAO, SAG

Operators Manual SUREFIRE II Single Phase PDI - SLR (24VDC, 115VAC & 230VAC) r#3

Oscillating piston flowmeters Series COVOL Positive displacement flowmeter for liquids

MANUAL CONTROL UNIT FOR ROTATING HEAT EXCHANGERS. MicroStart. IBC control

One-line distributor e.g. VEI-A. One-line aggregate GEI-A

INSTRUMENTATION & CONTROL

DMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor

CTE7000 / CTU7000 Series Miniature pressure transmitters

Flow limiter SP/SMB10 Dual flow series

DMP 331 DMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor. Pressure Transmitter. Industrial

Manually or pneumatically actuated piston pumps

Valve monitoring system VDK 200 A S02

ECONOMISER SERIES E2T USER MANUAL

DRIVE THE WATER CYCLE. January 10 TH 2013

EUGEN WOERNER GmbH & Co. KG Postfach 1661 DE Wertheim Am Eichamt 8 DE Wertheim. Pump aggregate. Drive: Use:

DESCRIPTION OPERATION. Product descripption SureFire Electrical Pump

User Manual. NiMH/NiCd Charger N, N, N, N Series

Conveyor trolley roller lubrication. GIS system for grease lubrication of trolleys and carriage rollers on monorail forged-chain conveyors

Flow limiter SP/SMB US

DMK 331P. Industrial Pressure Transmitter. Pressure Ports With Flush Welded Stainless Steel Diaphragm. accuracy according to IEC 60770: 0.

MultiPort Lubricator. Electric motor-driven, Grease and Oil. General. Technical Data. Motor R6 08/17

Flap-Type Flow Meter Prall

VECTOLUB Minimal Quantity Lubrication

Flow limiter SP/SMB9 for mounting plates

DMK 331P. Industrial Pressure Transmitter. Pressure Ports With Flush Welded Stainless Steel Diaphragm

Metering systems 0483EN October 2013 Metering units for sanitary or service water

DMP 331P DMP 331P. Industrial Pressure Transmitter. Pressure Ports And Process Connections With Flush Welded Stainless Steel Diaphragm

DMK 331P DMK 331P. Industrial Pressure Transmitter. Pressure Ports With Flush Welded Stainless Steel Diaphragm. Pressure Transmitter.

System description for cylinder lubrication and valve seat lubrication on large 4-stroke diesel engines

INLINE Flow sensor for hazardous area II 1 G/D - II 2 D - II 3 GD - I M1

MT50 & MT150 Electrical Multi-turn Valve Actuators

Transcription:

lubrication systems CME Electric pump for oil and soft grease volumetric lubrication systems

TABLE OF CONTENTS Table of contents 2 Description and technical data 3 Operation and technical data 4 Technical data (motor, sensors) 5 Command and control 6 Internal timer 7 Order code configurator 8 Overall dimensions (2L) 9 Overall dimensions (3L) 10 All ILC products should only be used for the intended purposes, as specified in this brochure and in all instructions. If the product is supplied with the operating instructions, the user is required to read and follow these instructions. Not all lubricants are suitable for central lubrication systems. The ILC lubrication systems or their components can not be used in combination with gases, liquid gases, pressurized gas in solution and liquids whose vapor pressure exceeds normal atmospheric pressure (1013 mbar) by more than 0.5 bar, maximum permissible temperature. Hazardous materials of any kind, especially those classified as such by the European Community Directive EC 67/548 / EEC, Article 2 (2), may be used in centralized lubrication systems of the ILC or their components and provided and / or marketed with them only after consultation with the ILC and after receiving written permission from the company. 2

CME Description and technical data Description CME electric pumps have been developed for single line lubrication systems fitted with volumetric metering valves or air-oil mixers. The unit consists of a gear pump, an electric motor, a low level switch, an electronic control card (upon request), a green LED (indicates power ON), a yellow LED (indicates pump working), a pressure gauge, a push button for intermediate lubrication and a pressure switch. Alternatively, the pressure switch can also be put at the end of the main line. The plastic cover protects the electrical components from environmental conditions like dirt or dust. The transparent impactresistant reservoir has a capacity of 2 or 3 litres. A set of valves which provides the decompression and bypass functions is connected to the gear pump. The lubricants that can be used are oil with a viscosity range between 50 and 1000 cst (CME-O) or soft grease with a NLGI consistency of 000-00 (CME-G). The two models have different sensors fitted for level control (see technical data sheet). example of an air-oil system example of a volumetric system P P MA DS MA DS M E M E WS ST WS ST DBV R DBV R 3

Operation and technical data CME Operation In order to control the system, it is necessary to alternate a working time (pump running) with a rest time (pump stopped). At the end of the rest time the pump starts and the lubricant pressure rises up to 22-30 Bar and activates the external volumetric valves or those that are integrated in the mixers (air-oil). The pressure switch, which is activated by the oil pressure, closes the contact and indicates that the pump is working properly. If it is not activated during the working time and the contact stays open, it will send an alarm signal. The electric level, which is open when the reservoir is empty, monitors the level of lubricant inside the reservoir. The push button can be pressed for intermediate lubricating operations. The green LED lights up to indicate that the pump is on, the yellow LED lights up to indicate that the pump is working. If there is an internal timer, that commands and controls the system, a red LED and a clean contact will indicate any faults. Technical data Reservoir capacity Capacities measured (A) Outlet connections Electrical connections Filling Pressure gauge Operating pressure Lubricants 2l - 3l 100cc/1' 50Hz 120cc/1' 60Hz 200cc/1' 24 V DC 2 BSP 1/4 seats (standard supplied with 1 left-hand lock cap) 1 cable gland for power supply 1 cable gland for signals Cap with 200 µ load filter 0-60 bar 24 bar (oil) 30 bar (grease) Oils 50 to 1000 mm²/s Soft greases NLGI 000 and 00 Operating temperature 0 C - 50 C Protection rating Weight (reservoir empty) IP-54 3.5 Kg (2l) 4.3 Kg (3l) (A) performances measured with lubricant with 100 viscosity (cst) and 5 bar back pressure. 4

CME Technical data (motor, sensors) Motor AC motor Rated voltage 115V 230V Rated power 110 W Rated current 1.5 A 0.78 A Operating mode according to DIN EN 60127-2 (B) Rated frequency Temperature switch S3, 20% 50/60 Hz Integrated DC motor Rated voltage Rated power Rated current Operating mode according to DIN EN 60034-1 (B) Internal fuse 24 V DC 60W 3 A S3, 20% 6.3 A Pressure switch Contact Calibration pressure Operating voltage Maximum switching current Open in the absence of pressure 22 bar less than 250 V AC 0.5 A Electric low oil level Reed contact Trip voltage closed in the presence of oil 1.5 A - 250 V AC - 200 V DC - 50 W Electric low soft grease level Capacitive sensor Operating voltages closed in the presence of soft grease 10 to 36 V DC Outlet load < 10 ma (24 V), < 15 ma (36 V) Protection against short circuit and reverse polarity Yes (B) S3 operating mode (intermittent operation) Indicates the ratio between the operating period and the shut-down period. 2 minutes cycle time at 20% -> 2minx0.2=0.4min (working time). Therefore a shut-down time of 1.6 minutes. The maximum working time is 6 minutes. The electric motor has a thermal protection that stops it when it reaches 120 C; it can only start again when the temperature drops below 100 C. 5

CME Command and control Electric pump without internal timer The pump is activated and controlled by the machine s PLC. It is supplied with a push button for possible intermediate lubricating operations, power LED and pump working LED. It also has a pressure switch for lubricant pressure control, an electric low level sensor (open when the reservoir is empty) and a pressure gauge. The power LED (GREEN) and the operating LED (YELLOW) are on the front panel. internal electronic card 6

Internal timer CME Electric pump with internal timer The pump is controlled by an internal timer. All settings can be programmed with the keys on the external front panel, without opening the cover. The various error and operating messages are displayed above the function keys. The power LED (GREEN), the operating LED (YELLOW) and the alarm LED (RED) are next to the display. The pump is supplied with a pressure switch for lubricant pressure control, an electric low level sensor (open when the reservoir is empty) and a pressure gauge. Functions Adjustment of the pause time in minutes-hours. Adjustment of the pause time according to the external pulses. Adjustment of the working time in seconds-minutes Circuit pressurisation control. Memory: at switch-on the pump starts from the point in which it was stopped. Pre-lubrication: at switch-on the pump starts with a lubrication cycle (working). internal electronic card 7

CME Order code configurator CME order code configurator 81 - G 2 - C T - 24V A B C D A (Lubricants) B (Reservoir) C (Control) D (Power supply voltage) Soft grease G 2L 2 External control CE 24 V DC 24V Oil O 3L 3 Internal electronics CT 115 V AC 115 230 V AC 230 Push-in fittings Code Figure Pipe Tapered thread 03.257.4 straight 6 BSP 1/4 03.257.2 90 6 BSP 1/4 Compression fittings Code Figure Pipe Tapered thread ZZZ106-005 straight 6 BSP 1/4 ZZZ106-105-L 90 6 BSP 1/4 8

CME Overall dimensions (2L) 9

Overall dimensions (3L) CME 10

MADE IN ITALY